You can copy from here when filling out the rest of the page.
Monroe County. City of Key West. Key West, Florida.
PROJECT PURPOSE:
Basic: The basic project purpose is to expand the existing pier to create two additional slips to facilitate the repeat transportation and mooring of vessel usage.
Overall: The overall project purpose is to expand the existing ferry terminal pier to create two additional slips to facilitate the mooring and repeat vessel usage and to facilitate the embarkment and disembarkement of passengers at the ferry terminal in Key West, Monroe County, Florida.
TO WHOM IT MAY CONCERN: The Jacksonville District of the U.S. Army Corps of Engineers (Corps) has received an application for a Department of the Army permit pursuant to Section 10 of the Rivers and Harbors Act of 1899 (33 U.S.C. §403) as described below:
APPLICANT: City of Key West
Cc/o Doug Bradshaw
Director, Port and Marine Services
201 William Street
Key West, FL 33040
WATERWAY AND LOCATION: The project would affect waters of the United States associated with the Florida Bay. The project site is located within an existing Ferry Terminal at the Eastern end of Key West Bight. The existing ferry terminal pier is in close proximity to the Navy operation facility on Trumbo Point's Pier D-1. The terminal is adjacent to 201 Grinnell Street, in Section 31, Township 67 South, Range 25 East; Key West, Monroe County, Florida 33040 (RE#s 00072082-004000 & 00072082-004001).
Directions to the site are as follows: From Miami, drive south on U.S. 1 Overseas Highway toward Key West. Turn right onto North Roosevelt Boulevard. Turn right onto Palm Avenue and travel across the Garrison Bight Bridge. Continue through the traffic light and turn left onto Eaton Street. Turn right onto Grinnell Street and drive toward the water on Grinnell Street to the ferry terminal parking lot entrance.
APPROXIMATE CENTRAL COORDINATES: Latitude: 24.562676°
Longitude: -81.7996°
PROJECT PURPOSE:
Basic: The basic project purpose is to expand the existing pier to create two additional slips to facilitate the repeat transportation and mooring of vessel usage.
Overall: The overall project purpose is to expand the existing ferry terminal pier to create two additional slips to facilitate the mooring and repeat vessel usage and to facilitate the embarkment and disembarkement of passengers at the ferry terminal in Key West, Monroe County, Florida.
EXISTING CONDITIONS: The proposed project is located at an existing ferry terminal pier within a commercial marina operated by City of Key West. The project area is within the limits of a submerged land lease area operated and maintained by the City of Key West. The existing ferry terminal pier is in close proximity to the Navy operation facility on Trumbo Point's Pier D-1. Approximately 2.3 acres of the submerged project area was surveyed to document the benthos and identify the location of any existing resources. According to the submitted attached benthic survey conducted by Atkins North America, Incorporated, no seagrass was observed within the proposed pier extension area and the bottom consists of soft sediment, rock rubble and macroalgae. One Siderastrea radians colony that measures 4 cm² was observed within the proposed project footprint approximately eleven meters from the edge of the existing pier. There are four (4) existing dolphin piling clusters, proposed for removal, each consist of a cluster of five wooden pilings and are colonized with sponges, zoanthids, hydroids, tunicates, and macroalgae. No coral colonies were observed on any of the dolphin pilings to be removed neither within the proposed project footprint. Overall, water depths within the project area ranged from six to twenty-one feet.
PROPOSED WORK: The applicant seeks authorization to expand the existing pier at the Key West Ferry Terminal. The proposed work will consist of the removal of four (4) wood clustered dolphin pilings, the construction of a 1,600-square foot (80’ long by 20’ wide) concrete pier extension, not to extend beyond the existing dolphin pile clusters; to install fifteen (15) 14” by 14” concrete batter and vertical piles, eight (8) wood fender piles, eight (8) cleats, an ADA ramp and a high speed fuel station at the end of the pier extension. Temporary turbidity curtains will be deployed for the duration of all construction activities, in/over waters of the United States. Work is proposed in U.S. navigable waters in accordance with the enclosed site plans (16 pages).
AVOIDANCE AND MINIMIZATION INFORMATION – The applicant has provided the following information in support of efforts to avoid and/or minimize impacts to the aquatic environment: Temporary turbidity curtains will be deployed for the duration of all construction activities, in/over waters of the United States. The overall square footage of the overwater structures is being reduced from 121 square feet to 80 square feet, not to extend beyond the already existing mooring piles, to maintain the appropriate setback (minimum) from the adjacent federally maintained channel.
COMPENSATORY MITIGATION – The applicant has offered the following compensatory mitigation plan to offset unavoidable functional loss to the aquatic environment: If it is determined that the issuance of a DA permit is appropriate, mitigation will be required. The applicant has indicated that the mitigation proposal will be based on the Keys Restoration Fund (KRF). Time lag and risk will be a required component of any mitigation requirement.
CULTURAL RESOURCES: The Corps is aware of historic property/properties within or in close proximity of the permit area. The Corps will initiate consultation with the State Historic Preservation Office and those federally recognized tribes with concerns in Florida and the Permit Area, and the Advisory Council on Historic Preservation as applicable pursuant to 33 CFR 325, Appendix C and Section 106 of the National Historic Preservation Act, by separate letter.
ENDANGERED SPECIES: The U.S. Army Corps of Engineers (Corps) has determined the project may affect, but is not likely to adversely affect (“MANLAA”) the West Indian manatee (Trichechus manatus). Since the proposal by the applicant is for in-water construction, potential impacts to the endangered West Indian manatee were evaluated using The Corps of Engineers, Jacksonville District, and the State of Florida Effect Determination Key for the Manatee in Florida, April 2013 (Key). Use of the Key resulted in the following sequential determination: A > B > C > G > H > I > N > 0 > P (1), “MANLAA”. This determination is partially based on the implementation of the Standard Manatee Conditions for In-Water Work, 2011. By letter dated April 25, 2013, the Corps received concurrence from the U.S. Fish and Wildlife Service (FWS) regarding MANLAA determinations for the West Indian manatee in accordance with 50 CFR 402.14(b)1 and pursuant to the Key. No further coordination with the FWS is required.
The project site is not within the American crocodile (Crocodylus acutus) critical habitat; however, it is within the species consultation area. By letter dated October 28, 2014, the FWS issued programmatic concurrence for projects in the Keys south of the intersection of U.S. Highway 1 and State Road 905 in Key Largo. The letter states that projects located in this range are unlikely to adversely affect the American crocodile if it meets one or more of the listed criteria. By using the programmatic letter, paragraph 2, the proposed project does not contain suitable nesting habitat that is accessible to the crocodile. Therefore, given that the proposed impact area meets these criteria as set by the FWS, the Corps has made a “MANLAA” determination in regard to the American crocodile. Pursuant to Section 7 of the Endangered Species Act, no further consultation with the Service is required.
The Corps has determined the proposed project may affect, but is not likely to adversely affect (“MANLAA”) the swimming green sea turtles (Chelonia mydas), loggerhead sea turtles (Caretta caretta) and their designated critical habitat, hawksbill sea turtles (Eretmochelys imbricata), Kemp’s ridley sea turtles (Lepidochelys kempii), leatherback sea turtles (Dermochelys coriacea), and the smalltooth sawfish (Pristis pectinata) species. A no effect determination was reached on smalltooth sawfish critical habitat, Nassau grouper (Epinephelus striatus), Acorpora sp. and its designated critical habitat and corals species; (Dendrogyra cylindrus, Orbicella annularis, Orbicella faveolata, Orbicella franksi, Mycetophyllia ferox). The Corps will request National Marine Fisheries Service concurrence with these determinations pursuant to Section 7 of the Endangered Species Act.
ESSENTIAL FISH HABITAT (EFH): This notice initiates consultation with the National Marine Fisheries Service on EFH as required by the Magnuson-Stevens Fishery Conservation and Management Act 1996. The proposal would impact approximately 1,600 square feet of submerged bottom utilized by various life stages of marine species. Our initial determination is that the proposed action would not have a substantial adverse impact on EFH or Federally managed fisheries in the Florida Keys. Our final determination relative to project impacts and the need for mitigation measures is subject to review by and coordination with the National Marine Fisheries Service.
NOTE: This public notice is being issued based on information furnished by the applicant. This information has not been verified or evaluated to ensure compliance with laws and regulation governing the regulatory program. The jurisdictional line has not been verified by Corps personnel.
AUTHORIZATION FROM OTHER AGENCIES: Water Quality Certification may be required from the Florida Department of Environmental Protection and/or one of the state Water Management Districts.
COMMENTS regarding the potential authorization of the work proposed should be submitted in writing to the attention of the District Engineer through the Miami Permits Section, 9900 Southwest 107th Avenue, Suite 203, Miami, Florida, 33176, within 30 days from the date of this notice (i.e. on or before March 29, 2017).
The decision whether to issue or deny this permit application will be based on the information received from this public notice and the evaluation of the probable impact to the associated wetlands. This is based on an analysis of the applicant's avoidance and minimization efforts for the project, as well as the compensatory mitigation proposed.
QUESTIONS concerning this application should be directed to the project manager, Gletys Guardia-Montoya at the letterhead address, by electronic mail at Gletys.Guardia-Montoya@usace.army.mil, or by telephone at 305-526-2515.
IMPACT ON NATURAL RESOURCES: Coordination with U.S. Fish and Wildlife Service, Environmental Protection Agency (EPA), the National Marine Fisheries Services, and other Federal, State, and local agencies, environmental groups, and concerned citizens generally yields pertinent environmental information that is instrumental in determining the impact the proposed action will have on the natural resources of the area.
EVALUATION: The decision whether to issue a permit will be based on an evaluation of the probable impact including cumulative impacts of the proposed activity on the public interest. That decision will reflect the national concern for both protection and utilization of important resources. The benefits, which reasonably may be expected to accrue from the proposal, must be balanced against its reasonably foreseeable detriments. All factors which may be relevant to the proposal will be considered including cumulative impacts thereof; among these are conservation, economics, esthetics, general environmental concerns, wetlands, historical properties, fish and wildlife values, flood hazards, floodplain values, land use, navigation, shoreline erosion and accretion, recreation, water supply and conservation, water quality, energy needs, safety, food, and fiber production, mineral needs, considerations of property ownership, and in general, the needs and welfare of the people. Evaluation of the impact of the activity on the public interest will also include application of the guidelines promulgated by the Administrator, EPA, under authority of Section 404(b) of the Clean Water Act or the criteria established under authority of Section 102(a) of the Marine Protection Research and Sanctuaries Act of 1972. A permit will be granted unless its issuance is found to be contrary to the public interest.
The US Army Corps of Engineers (Corps) is soliciting comments from the public; Federal, State, and local agencies and officials; Indian Tribes; and other Interested parties in order to consider and evaluate the impacts of this proposed activity. Any comments received will be considered by the Corps to determine whether to issue, modify, condition, or deny a permit for this proposal. To make this determination, comments are used to assess impacts to endangered species, historic properties, water quality, general environmental effects, and the other public interest factors listed above. Comments are also used to determine the need for a public hearing and to determine the overall public interest of the proposed activity.
COASTAL ZONE MANAGEMENT CONSISTENCY: In Florida, the State approval constitutes compliance with the approved Coastal Zone Management Plan. In Puerto Rico, a Coastal Zone Management Consistency Concurrence is required from the Puerto Rico Planning Board. In the Virgin Islands, the Department of Planning and Natural Resources permit constitutes compliance with the Coastal Zone Management Plan.
REQUEST FOR PUBLIC HEARING: Any person may request a public hearing. The request must be submitted in writing to the District Engineer within the designated comment period of the notice and must state the specific reasons for requesting the public hearing.
5
1
A-1
SITE PLAN, INDEX, REVISION LOG, PROJ. INFORMATION
A-2
1
A-2
FULL DOCK EXTENSION PLAN & ELEVATIONS
A-3
1
A-3
DOCK EXTENSION PLAN S& ELEVATIONS
A-4
A-4
FRAMING PLAN & ADA DETAILS
A-5
A-5
M.E.P. AND FIRE SAFTY & SPECS.
K EY W E S T B I G H T
T
R
U
20
'
A-6
ENVIORMENTAL SPECS / GENERAL SPECS.
KEY WEST HARBOR
B
UP
A-6
M
FERRY TERMINAL
O
R
CONC.
APRON
A-7
O
A
6
PROPOSED
A-8
EXISTING
80'-00"
(4
20'-1 1/4"
5
4
A-9
'R
ELEV.
C L E A R
11
18
19
20
12
TRASH
13
21
F I R E
UP
FLAT
PIKE
ARCHITECTS
17
LA N E -
20'-0"
/W
16
10
HCP
14
ARCHITECTS
PLANNERS
CONSULTANTS
EXISTING BURIED
FUEL TANK
F I R E
LA N E -
34
A-14
A-15
33
C L E A R
32
KEY WEST HARBOR
31
30
29
28
27
26
25
24
23
471 US HIGHWAY #1
SUITE 101
KEY WEST, FLA. 33040
305-296-1692
A-13
22
FLOOD ZONE
VE - 10'
G R I N N E L L
A-16
AE - 9'
S T R E E T
PIKE
ARCHITECTS
A-17
** DEMO FIRST SET OF
EXISTING DOLPHINS AS
REQUIRED
A-18
A-19
A-20
ARCHITECT : PIKE ARCHITECTS
471 U.S. HWY. 1, SUITE 101, KEY WEST
FLORIDA 305-296-1692
C
REVISION #
SITE PLAN - PARTIAL
S-1
DRAWING INDEX GENERAL NOTES
S-2
S-2
SITE PLAN
S-3
S-3
PILE LAYOUT AND BENT FRAMING PLAN
S-4
S-4
PS SLAB FRAMING PLAN AND DETAILS
S-5
S-5
GENERAL SECTIONS
S-6
S-6
SECTIONS AND DETAILS
S-7
S-7
TYPICAL PILE CAP REINFORCING
S-8
S-8
GRID 12 PILE CAP REINFORCING
S-9
S-9
GRID 16 PILE CAP REINFORCING
S-10
S-10
PRESTRESSED BEAMS REINFORCEMENT (N.I.)
S-11
S-11
WOOD FENDER PILES AND DOLPHINS
MECHANICAL
MECHANICAL
SHEET #
SHEET #
CONSTRUCT 20'W X 80' CONCRETE
EXTENSION OF EXISTING DOCK FOR
FERRY PASSENGER EMBARKMENT
& DISEMBARKMENT
LEGAL DESCRIPTION:
CERTIFICATE OF COMPLIANCE
THIS IS TO CERTIFY THAT I AM A DULY QUALIFIED ARCITECT
LICENSED TO PRACTICE IN THE STATE OF FLORIDA. IT IS
FURTHER CERTIFIED THAT I HAVE REVIEWED THE DESIGN,
SPECIFICATIONS AND PLANS FOR THE COMMERCIAL
STRUCTURE PROPOSED FOR CONSTRUCTION AT 100
GRINNELL STREET, KEY WEST FLORIDA, AND IS IN
COMPLIANCE WITH THE ORDINANCE ADOPTED BY THE CITY
OF KEY WEST, MONROE COUNTY NO. 87-17 REGARDING
COASTAL CONSTRUCTION REQUIREMENTS IN THE CITY OF
KEY WEST, IN THAT THE STRUCTURE IS DESIGNED ON
ADEQUATELY ANCHORED PILINGS OR COLUMNS AND IS
SECURELY ANCHORED TO SAME IN ORDER TO WITHSTAND
VELOCITY WATERS AND HURICANE WAVE WASH
ASSOCIATED WITH THE BASE FLOOD FLOW.
LOWEST FINISHED FLOOD ELEVATION- VE 10' N.G.V.D.
P-2
P-3
P-4
P-5
M-1
SEAL
M-2
DATE____________________
M-3
SIGNATURE _________________
ELECTRICAL
ELECTRICAL
SHEET #
SHEET #
E-1
E-1
ELECTRICAL PLAN
E-2
E-2
SCHEDULES & RISER DIAGRAMS
1227 LAKE MIRIAM DRIVE, LAKELAND, FLA. 33813 863-646-6277
SCOPE OF WORK:
P-1
REVISION #
STRUCTURAL ENGINEERING : M. CORDERO & ASSOCIATES CA 6278
MARCO A. CORDERO: LIC. # 038586
Scale: 1:750
SHEET #
S-1
REVISION #
1
A-1
STRUCTURAL
EXTENDED
STRUCTURAL
RE: -
PROJECT APPROVALS:
SITE
A parcel of Submerged land lying and being in Section 31, Township 68
South Range 25 East, Island of Key West, Monroe County, Florida, and a
part of Key West Bight and being more particularly described as
follows: Commencing at the intersection of the Northwesterly
Right-of-Way Line of Caroline Street and the Southwesterly
Right-of-Way Line of Grinnell Street; thence N.33°58'50"W., along the
said Southwesterly Right-of-Way Line of William Street a distance of
351.85 feet to the seaward face of a concrete seawall lying on the Key
West Bight and the Point of Beginning; thence continue N 33°58'50" W
along the Northerly extension of the Southwesterly Right-of-Way Line of
Grinnel Street for 431.59 feet to the federally Maintained Shipping
Channel Line; thence S 86°27'30" E and along the said Federally
Maintained Shipping Channel Line for a distance of 439.01 feet; thence
N 05°58'10" E for 156.10 feet; thence N 84° 01'50" W for 40.00 feet;
thence N 05°58'10" E for 145.04 feet; thence S 82°58'21" E for 106.23
feet to the Approximate Mean High Water line (Elev. 0.92 N.G.V.D.,
1929); thence meander the said Mean High Water Line in a Southerly
direction for 558.2 feet, more or less to the face a Concrete Seawall;
thence N 81°29'40" W along the said concrete seawall for a distance of
112.13 feet, more or less; thence S 56°50'27" W and continuing along
the face of the concrete seawall for 151.65 feet to the Point of
Beginning.
Parcel contains 134125 square feet or 3.08 acres, more or less.
US 1
TO MIAMI
GULF OF
MEXICO
ITEM
NOTES:
APPROVAL #
DATE
DEVELOPMENT REVIEW COMMITEE -
-
H.A.R.C.
-
-
BOARD OF ADJUSTMENT
-
-
CITY OF KEY WEST
DEVELOPEMENT AGREEMENT
-
-
KEY WEST BIGHT BOARD
-
-
KEY WEST BIGHT
GARRISON BIGHT
KEY WEST AIRPORT
FORT ZACHARY
TAYLOR
ATLANTIC OCEAN
N
KEY WEST
LOCATION MAP
THIS STRUCTURE DESIGNED TO
MEET THE FOLLOWING
FBC 2014
A.S.C.E. 24-05 REGULATIONS
LIVE LOAD SEE STRUCTURALS
WIND LOAD SEE STRUCTURALS
E-3
E-4
A
F L O R I D A
15
A-12
B
W E S T,
S T R E E T
)
3
9
SHEET #
G R I N N E L L
K E Y
59
8
1
A-11
5.
7
2
A-10
1 0 0
D
E-5
PROJECT NUMBER:
16.23
DRAWN: KM/TSN
CHECKED: PMP
DATE: 09-19-2016
E-6
E-7
E-8
E-9
E-10
ARCHITECT SEAL
PETER PIKE
SHEET #
A-1
7
6
5
4
3
2
1
For Permitting Only Not For Construction
A-1
DOCK LENGTH: 121'-0"
DOCK WIDTH: 20'-0"
OF 6
PETER M. PIKE FLA. REGISTRATION # AR0015198
TITLE
Copyright 2016
SHEET #
NEW EMBARKMENT / DISSEMBARKMENT RAMP EXTENSION
REVISION #
REVISIONS: DATE
#1
12-29-2016
1
This drawing is the property of
PETER PIKE ARCHITECT
Unless otherwise provided for by
contract, the contents of this drawing
are confidential and shall not be
transmitted to any other party
except as agreed to by
PETER PIKE ARCHITECT
ARCHITECTURAL
2
NEW EMBARKMENT / DISSEMBARKMENT RAMP
K EY W E S T B I G H T
FERRY TERMINAL
ARCHITECTURAL
3
SITE PLAN /
PROJECT NOTES
PROJECT CALCS.
SCHEDULE OF DRAWINGS
4
PROJECT:
REVISION LOG.
SHEET #
D
6
DRAWING TITLE:
7
7
6
5
4
3
2
REVISIONS: DATE
#1
12-29-2016
1
12
D
11
10
8
7
EXISTING
FUELING
STATION
6
PUMP
HOUSE
5
4
3
2
FUEL
HOSE
1
P&W
FH
FLAT
FHC
FH
+11'-4"
NEW ADA RAMP
RAMP
MAX RAMP
1:12
FH
DN.
FLAT
+1'-4"
RAMP
FLAT
DN.
MAX RAMP
1:12
RAMP
FLAT
DN.
MAX RAMP
1:12
RAMP
FLAT
DN.
188'-0"
NEW CONCRETE DOCK EXTENSION
FULL DOCK PLAN
C
9
8
7
6
5
80'-0"
16
14
A
15
3
2
1
188'-0"
NEW CONCRETE DOCK EXTENSION
15
A
4
EXISTING COVERED WALKWAY AND DOCK
13
A
14
12
B
12
A
13
NEW ADA RAMP
12
SEE STRUCTURAL DRAWINGS
WATER LINE
10
A
11
+11' - 4"
10
0"
1
PROJECT:
A-4
HARBOR BOTTOM
B
2
3
4
5
6
7
8
9
188'-0"
80'-0"
EXISTING COVERED WALKWAY AND DOCK
NEW CONCRETE DOCK EXTENSION
10
A
12
A
12
B
13
A
13
14
A
14
15
A
15
16
NEW ADA RAMP
10
11
12
0"
SEE STRUCTURAL DRAWINGS
+11' - 4"
TOP OF DECK
0"
WATER LINE
1
A-4
A
PROJECT NUMBER:
16.23
DRAWN: KM/TSN
CHECKED: PMP
DATE: 09-19-2016
HARBOR BOTTOM
3
A-2
FULL DOCK NORTH ELEVATION
Scale: 1:150
SHEET #
A-2
7
6
5
4
3
2
1
OF 6
PETER M. PIKE FLA. REGISTRATION # AR0015198
Scale: 1:150
FULL DOCK EXTENSION
PLAN & ELEVATION
1
FULL DOCK SOUTH ELEVATION
DRAWING TITLE:
2
A-2
NEW EMBARKMENT / DISSEMBARKMENT RAMP
K EY W E S T B I G H T
FERRY TERMINAL
KEY WEST BIGHT HARBOR
Scale: 1:150
EXTENDED
1
A-2
EXISTING COVERED WALKWAY AND DOCK
ARCHITECTS
PLANNERS
CONSULTANTS
471 US HIGHWAY #1
SUITE 101
KEY WEST, FLA. 33040
305-296-1692
80'-0"
EXISTING BULKHEAD
A-4
EXISTING HARBOR WALK
3
UP
P&W
PIKE
ARCHITECTS
For Permitting Only Not For Construction
9
13
Copyright 2016
10
A
14
12
A
This drawing is the property of
PETER PIKE ARCHITECT
Unless otherwise provided for by
contract, the contents of this drawing
are confidential and shall not be
transmitted to any other party
except as agreed to by
PETER PIKE ARCHITECT
15
12
B
EXISTING FERRY TERMINAL
13
A
EXISTING
BENT
16
14
A
EXISTING
BENT
15
A
EXISTING BULKHEAD
KEY WEST BIGHT HARBOR
EXISTING HARBOR WALK
SEE STRUCTURAL DRAWINGS
7
6
5
4
3
2
1
REVISIONS: DATE
#1
12-29-2016
KEY WEST BIGHT HARBOR
15
A
16
1"X 1" THICK
3"X12 2
4
BRACKET
3" DIA.
4
15
14
9'-2 1/2"
9'-2 1/2"
11
1" PLATE
10"X15"X 4
3"
6"
3/3
SIDE
A-5
11"
NOTE:
GC TO COORDINATE H2O &
ELECTRICAL SYSTEM. SEE SPECS.
5'-0"
EXISTING DOCK TO TERMINAL
10'-0"
10'-0"
1'-6"
REFER TO STRUCTURAL AS REQUIRED
S.S. BASE ANCHOR DETAIL
PIKE
ARCHITECTS
P&W
Scale: 3/4" = 1'-0"
FH
10'-0"
4'-0"
NOTE:
PROVIDE CLASS "B" FIRE
EXTINGUISHER IN POLE
MOUNTED S.S. CABINET
FH
C
2
4'-0"
NEW WOOD FENDER PILES
MATCH EXISTING
SEE STRUCTURAL
1
1
A-3
3/16" = 1'-0"
15
A
14
A
16
13
A
15
12
B
14
EXISTING
FLAT
DN.
MAX RAMP
1:12
60" MIN.
EXTEND EXISTING
ADA RAILING
A-4
EXTENSION DOCK PLAN
PENETRATION NOTE:
COORDINATE ALL PENETRATION SIZES
& LOCATIONS WITH PRECAST PANEL
MANUFACTURER.
TYPICAL AT ALL PANELS.
PROVIDE SHOP DRAWINGS
FOR ENGINEER APPROVAL.
1'-3"
1'-6"
P&W
RAMP
A-4
10'-0"
NOTE:
GC TO COORDINATE ANCHORING
OF DOCK CLEATS WITH ARCHITECT
& ENGINEER PRIOR TO DRILLING
PRE-CAST CONCRETE SLABS.
10'-0"
DUAL FUEL
DISPENSER
FE
FIRE CONTROL
STATION
REFER TO STRUCTURAL FOR
CONCRETE SPECIFICATIONS
4
NEW FUELING
STATION
FHC
CONFIRM
EXISTING
FH
3'-0"
FIRE EXTINGUISHER
CLASS "B"
LOCATED HERE
CONFIRM
EXISTING
4'-0"
1'-6" MIN.
ARCHITECTS
PLANNERS
CONSULTANTS
12
A
10
A
EXTENDED
FRONT
10
471 US HIGHWAY #1
SUITE 101
KEY WEST, FLA. 33040
305-296-1692
6"
12
3" DIA.
4
13
80'-0"
18'-5"
1'-4"
9'-2 1/2"
18'-5"
9'-2 1/2"
9'-2 1/2"
18'-5"
9'-2 1/2"
18'-5"
9'-2 1/2"
9'-2 1/2"
9'-2 1/2"
9'-2 1/2"
5'-0"
11
10
PROJECT:
12
REFER TO STRUCTURAL FOR
CONCRETE SPECIFICATIONS
FUEL
HOUSE
P&W
CONTAINMENT
VALVE BOX
10'-0"MATCH EXISITING
B
NEW WOOD FENDER PILES
MATCH EXISTING
SEE STRUCTURAL
NEW ADA RAMP
CONTRACTOR TO SUBMIT SHOP
DRAWINGS FOR DOCK PENETRATION
& TRANSITION OF CONDUITS SWEEPS
10'-0"
1
A-4
EXISTING DOCK TO TERMINAL
EXISTING
BENT
PROVIDE WATER LINE FENDER PILE
PROTECTION SLEEVE FOR FROM
MARINE BORES.
MUST EXTEND ABOVE HIGH TIDE AND
BELOW LOW TIDE LEVELS. SUBMIT
PRODUCT FOR ARCHITECT & OWNER
APPROVAL.
10'-0"
EXISTING
BENT
WATER LINE
A
PROJECT NUMBER:
16.23
DRAWN: KM/TSN
CHECKED: PMP
DATE: 09-19-2016
HARBOR BOTTOM
2
A-3
7
6
SHEET #
EXTENSION DOCK ELEVATION
A-3
3/16" = 1'-0"
5
4
Copyright 2016
1'-0 1/2"
EXISTING
BENT
3" DIA.
4
5'-0"
3
For Permitting Only Not For Construction
9'-2 1/2"
1
3"X12 1
2"X 4" THICK
BRACKET
1" PLATE
10"X15"X 4
3
A-3
9'-2 1/2"
2
1
OF 6
PETER M. PIKE FLA. REGISTRATION # AR0015198
9'-2 1/2"
9'-2 1/2"
18'-5"
This drawing is the property of
PETER PIKE ARCHITECT
Unless otherwise provided for by
contract, the contents of this drawing
are confidential and shall not be
transmitted to any other party
except as agreed to by
PETER PIKE ARCHITECT
9'-2 1/2"
18'-5"
NEW EMBARKMENT / DISSEMBARKMENT RAMP
K EY W E S T B I G H T
FERRY TERMINAL
9'-2 1/2"
18'-5"
DOCK EXTENSION
PLAN & ELEVATION
1'-4"
TOP
4"
1'-0 1/2"
13
7'-6"
D
10
A
A-4
1" DIA. BOLT
HOLES
1 1/2"
18'-5"
1" PLATE
10"X15"X 4
1 1/2"
12
A
80'-0"
2"
1
3"X12 1
2"X 4" THICK
BRACKET
12
B
DRAWING TITLE:
10"
13
A
EXISTING
BENT
15"
14
A
+/- 12'-9" EXISTING
10'-0"
4 1/2"
10"
10
2
POST CAP
L
20'-0"
CONTINUOUS METAL
GUARD RAIL
1 1/2" sleeves for water
2" sleeve for pole lights
2" sleeve for F.H. electrical
4" sleeve, F.H.
fuel line verify size
10'-0"
1'-0"
1'-0"
1'-0"
4" sleeve for
P.S. electrical
4'-2"
REVISIONS: DATE
#1
12-29-2016
1
C
3'-6"
2'-10" 1'-0"
NOTE: PROVIDE RAILING
AND SHOP DRAWINGS FOR
ARCHITECT APPROVAL
4" sleeve for
P.S. electrical
1'-0" 2'-10"
4'-2"
2"
NEW CONCRETE DOCK PORTION
MATCH EXISTING
RAILING DETAILS
6'-4"
60" MIN.
Scale: 1/4" = 1'-0"
EXPANSION JOINT MATERIAL
3
A-3
4
A-4
RAMP SECTION
2
A-4
RAILING DETAIL
Scale: 3/4" = 1'-0"
MATCH EXISTING BASE DETAIL
Scale: 1/4" = 1'-0"
PROJECT:
EXTENDED
ANCHOR BASE DETAIL
EXISTING 10X10 FIRE
TREATED COLUMNS
DECKING TO BE:
5/4X6 IPE DECKING,
S.S. SCREWS, SQUARE HEADS
DECKING TO BE:
5/4X6 IPE DECKING,
S.S. SCREWS, SQUARE HEADS
BLOCKING AT EVERY JOIST
2"X3" SS ANGLES AT EVERY
JOIST WITH TAPCONS INTO
EXISTING CONCRETE SLAB
B
NEW EMBARKMENT / DISSEMBARKMENT RAMP
K EY W E S T B I G H T
FERRY TERMINAL
CONFIRM
EXISTING
1'-3"
ADA RAMP FRAMING PLAN
2X10 FIRE TREATED LEDGER
BOLTED W/ 1/2" SS THRU BOLTS
@ 24" O.C. STAGGERED T & B
SIMPSON LUS210SS HANGER
0"
3
A-4
ARCHITECTS
PLANNERS
CONSULTANTS
EXIST. HT.
C
10X10 FIRE TREATED
POST TO MATCH EXISTING
DETAILS ((1) OF 4)
PIKE
ARCHITECTS
Copyright 2016
LOW SLOPED CONCRETE SLAB
POUR INTERGAL WITH DOCK TOP
COATING
1.5" ALLUM. ROUND CONTINOUS
GRAB RAIL. POWDER COAT WHITE
PROVIDE SHOP DRAWINGS FOR
ARCHITECT APPROVAL
EXISTING
FLAT
Scale: 1/4" = 1'-0"
"FIBERON" PROVINCIAL RAILING SYSTEM
W/NEW ENGLAND POST CAP
SQUARE SPINDLES PAINT TO MATCH
EXISTING RAILING
PROVIDE SHOP DRAWINGS FOR
ARCHITECT APPROVAL
NOTE:
CONTRACTOR TO VERIFY ALL
SLEEVE SIZES PRIOR TO WORK
This drawing is the property of
PETER PIKE ARCHITECT
Unless otherwise provided for by
contract, the contents of this drawing
are confidential and shall not be
transmitted to any other party
except as agreed to by
PETER PIKE ARCHITECT
FIRE TREATED 2X10's
RIPPED TO REQUIRED
PITCH (<1" PER FT.)
RIPPED 2X FIRE TREATED
FHC
A-4
4
CONFIRM
EXISTING
CONC. FORMED
TRASITION RAMP
TYPICAL DOCK CROSS SECTION
471 US HIGHWAY #1
SUITE 101
KEY WEST, FLA. 33040
305-296-1692
2X10 FIRE TREATED LEDGER
BOLTED W/ 1/2" SS THRU BOLTS
@ 24" O.C. STAGGERED T & B
DEMO EXSITING TREADS TO
EXISTING RAMP FRAMING
1
A-4
3'-6"
PITCH DOWN <1" PER FT. (+/- 5/8" PER. FT.)
(20'-00" FIELD CONFIRM)
10'-0"
FIELD VERIFY
3'-0"
13"
9" VERIFY
1/4" THICK EPOXY COAT TOPPING
@ ALL NEW CONCRETE DOCK AREAS.
PROVIDE SPEC. SHEET TO ARCHITECT
FOR PRIOR APPROVAL.
Additional Maneuvering Clearance for Alcoves
A
FRAMING PLAN
& ADA DETAILS
DRAWING TITLE:
Fig 4
Mimimum Clear Floor Spaces for Wheelchairs
PROJECT NUMBER:
16.23
DRAWN: KM/TSN
CHECKED: PMP
DATE: 09-19-2016
SHEET #
A-4
7
6
5
4
3
2
1
OF 6
PETER M. PIKE FLA. REGISTRATION # AR0015198
5'-0"
D
1/4" THICK EPOXY COAT TOPPING
@ ALL NEW CONCRETE DOCK AREAS.
PROVIDE SPEC. SHEET TO ARCHITECT
FOR PRIOR APPROVAL.
11
EXISTING
BENT
12
3
For Permitting Only Not For Construction
10
A
4
2'2"
12
A
EXISTING
BENT
12
B
5
3'-4"
6
1'-6"
7
4
15
A
14
A
16
2
13
A
15
12
B
14
12
A
1
PROVIDE 3"I.D. SLEEVE FOR
ELECTRICAL & 1 1/4" ID
SLEEVE FOR WATER.
CONTRACTOR VERIFY SIZES
PRIOR TO ANY WORK
1
A-4
13
PROVIDE 4" I.D. SLEEVE AT SLAB FOR
WATER LINE, CONTRACTOR TO VERIFY
EXACT LOCATION & SIZE WITH
MANUFACTURER PRIOR TO ANY WORK
LINE OF NEW FUEL VERIFY ALIGNMENT
WITH EXISTING FUEL LINE, VERIFY
EXACT LOCATION ON SITE AS REQUIRED
SEE DETAIL 1/A-4
12
11
10
P&W
NEW FUEL CONNECTION AND
HOSE REELS - CONTRACTOR TO
PROVIDE DESIGN BUILD COORDINATION
AND CONSTRUCTION PER CITY REQUIREMENTS
AND APPROVALS: CONTACT CITY MARINA
MANAGER FOR DETAILS AND SPECS
FH
TO NEW "A" UPGRADED CIRCUIT
TO NEW "D" UPGRADED CIRCUIT
TO NEW "C" UPGRADED CIRCUIT
TO NEW "B" UPGRADED CIRCUIT
FH
B
B
B
TO NEW "E" UPGRADED CIRCUIT
B
P&W
PROVIDE EMERGENCY
SHUT OFF FOR FUEL PUMP
C
HOSE BIB
ON COLUMN
PROVIDE 3"I.D. SLEEVE FOR
ELECTRICAL & 1 1/4" I.D.
SLEEVE FOR WATER.
CONTRACTOR VERIFY SIZES
PRIOR TO ANY WORK
LINE OF NEW
ELECTRICAL CONDUIT
SEE DETAIL 1/A-4
NOTE:
RUN NEW ELECTRICAL SERVICE FEEDER LINES
DOWN UNDERSIDE OF EXISTING WALKWAY FROM
FERRY TERMINAL BUILDING & FIELD VERIFY NEW
CORE DRILL AT EXISTING DOCK TO RUN NEW
FEEDER LINE UNDER NEW DOCK EXTENSION
ELECTRICAL & PLUMBING LINE SCHEMATIC EXTENSION DOCK PLAN
Scale: 3/16" = 1'-0"
SEE ELECTRICAL DRAWINGS
EXTENDED
DOCK EQUIPMENT SPECIFICATIONS:
FHC
PILE CAPS:
MANUFACTURER: AMERICAN DOCK BOXES OR EQUAL
MODEL #: ROUND PILE CAPS
COLOR: WHITE
PROVIDE SHOP DRAWING OF SLEEVE PENTRATIONS AT
SLAB
DECK CLEATS:
18" HEAVY DUTY CLOSED BASE CLEATS, GALVANIZED IRON
USE 3/4" SS JBOLTS, WET SET TO DOCK MATCH EXISTING SETBACK DIMENSIONS
MANUFACTURER: SEA DOG OR EQUAL
MODEL #: 040818
B
P&W
POWER PEDESTAL
MARINA POWER - MODEL #PCMFS 12 UTILITY PEDESAL OR EQUAL
"WHITE" WITH - 100 AMP BRK & 50 AMP BRK AT EACH SIDE & RECEPTICALS
HOSE BIB WITH BACKFLOWS BOTH SIDES
PROVIDE SHOP DRAWING OF SLEEVE PENTRATIONS AT SLAB
LIGHT FIXTURE SCHEDULE:
MARK FIXTURE TYPE MANUFACTURER/MODEL #
COMMENTS
DOCK GENERAL LIGHTING TO MATCH
EXISTING CITY PIER POLE LIGHTING
DL
B
MATCH EXISTING
LIGHT FIXTURES
SEE ELECTRICAL DRAWINGS
ELECTRICAL FIXTURE NOTE: PROVIDE SUBMITTAL FOR ARCHITECT & OWNER APPROVAL.
DRAWING TITLE:
FH
FIRE HOSE CABINET:
MANUFACTURER: MARINA POWER COMPANY OR EQUAL
MODEL #: FC1 CABINET (39"WX10"DX42"H & Fire Extinguisher Cabinet
COLOR: WHITE
FIRE EXTINGUISHER: TYPE "B"
PROVIDE SHOP DRAWING OF SLEEVE PENTRATIONS AT SLAB
PROJECT:
FUEL DISPENSOR:
MANUFACTURER: PMC, PIPE MEASURE CONTROL
MODEL #: FUEL DISPENSOR, FH-515-MA-4M, 60GPM
1 1/2" HOSE, 100' HOSE, STAINLESS STEEL
PROVIDE STAINLESS STEEL CONTAINMENT/SAFETY VALE
BOX AND SAFETY VALVE BELOW FUEL HOUSE. PROVIDE
SHOP DRAWINGS FOR ARCHITECT & OWNER APPROVAL.
A
DOCK
ELECTRICAL PLAN
1
A-5
Copyright 2016
B
B
B
This drawing is the property of
PETER PIKE ARCHITECT
Unless otherwise provided for by
contract, the contents of this drawing
are confidential and shall not be
transmitted to any other party
except as agreed to by
PETER PIKE ARCHITECT
ALTERNATE #1:
PROVIDE 2 FUEL HOUSE PUMPS AT
END CORNERS OF DOCK
B
ARCHITECTS
PLANNERS
CONSULTANTS
NEW EMBARKMENT / DISSEMBARKMENT RAMP
K EY W E S T B I G H T
FERRY TERMINAL
FE
FHC
DL
471 US HIGHWAY #1
SUITE 101
KEY WEST, FLA. 33040
305-296-1692
FH
DL
PIKE
ARCHITECTS
A-4
DL
CLASS "B"
DL
BASE BID:
PROVIDE 1 FUEL HOUSE PUMP AT
CENTER OF DOCK
PENETRATION NOTE:
COORDINATE ALL PENETRATION
SIZES & LOCATIONS WITH
PRECAST PANEL MANUFACTURER.
TYPICAL AT ALL PANELS.
PROVIDE SHOP DRAWINGS
FOR ENGINEER APPROVAL.
REVISIONS: DATE
#1
12-29-2016
10
A
CONTRACTOR TO PROVIDE LIGHT POLE ANCHOR BASE PLATE
DETAILS FROM MANUFACTURE FOR ARCHITECT APPROVAL
PROVIDE 3" I.D. SLEEVE AT SLAB FOR
FUEL LINE & 2" I.D. SLEEVE FOR
ELECTRICAL, CONTRACTOR TO VERIFY
EXACT LOCATION & SIZE WITH
MANUFACTURER PRIOR TO ANY WORK
D
3
PROJECT NUMBER:
16.23
DRAWN: KM/TSN
CHECKED: PMP
DATE: 09-19-2016
SHEET #
A-5
7
6
5
4
For Permitting Only Not For Construction
5
3
2
1
OF 6
PETER M. PIKE FLA. REGISTRATION # AR0015198
6
2
7
5
4
3
ENVIRONMENTAL NOTES AND SPECIFICATIONS
1. Key West Bight Terminal, 201 Grinnell St, FDEP #9802172
2. Conch Harbor Marina, 951 Caroline St, FDEP #8735043
UNIDENTIFIED AREAS OF CONTAMINATION
When encountering or exposing any abnormal condition indicating the presence of a hazardous or toxic waste, or contaminants, cease
operations immediately in the vicinity and notify the City of Key West Engineer. The presence of tanks or barrels; discolored earth, metal,
wood, ground water, etc.; visible fumes; abnormal odors; excessively hot earth; smoke; or other conditions that appear abnormal may
indicate hazardous or toxic wastes or contaminants and must be treated with extreme caution.
6.1 FINISHED FLOOR SLAB SURFACES SHALL BE PLANE SURFACES AS SHOWN ON THE DRAWINGS. WHERE DRAINS OCCUR SLOPE
FLOOR EVENLY TO DRAINS.
6.2 INTERIOR SLABS SHALL BE SCREEDED WITH A STRAIGHT EDGE, FLOATED TO THE REQUIRED LEVEL, AND STEEL TROWELED TO A
SMOOTH HARD FINISH.EXTERIOR SLABS SHALL BE BROOM FINISHED.
6.3 CONCRETE FLOORS SHALL BE CHECKED FOR TRUENESS WITH AN 8 FOOT STRAIGHT EDGE. ANY DEVIATION FROM THE LINE OF
THE STRAIGHT EDGE BY MORE THAN 1/4" SHALL BE REPAIRED IN A MANNER SATISFACTORY TO THE ARCHITECT.
7. AFTER CONSTRUCTION IS COMPLETED, THOROUGHLY CLEAN ALL EXPOSED FLOORS WITH SOAP AND WATER.
8. CONTROL JOINTS SHALL BE FORMED AS INDICATED ON DRAWINGS, OR FORMED WITH METAL KEYWAY TO REMAIN IN THE
SLAB.SLABS WITH AN APPROVED LIQUID CURING COMPOUND AND SEALING AGENT, APPLIED IN ACCORDANCE WITH THE
MANUFACTURERS RECOMMENDATIONS.
Make every effort to minimize the spread of contamination into uncontaminated areas. Immediately provide for the health and safety of all
workers at the job site and make provisions necessary for the health and safety of the public that may be exposed to any potentially
hazardous conditions. Provisions shall meet all applicable local, State, and Federal laws, rules, regulations or codes covering hazardous
conditions and will be in a manner commensurate with the gravity of the conditions.
The City of Key West Engineer and/or Prime Contractor will coordinate and mobilize a qualified Contamination Assessment/Remediation
(CAR) Contractor. Qualifications of such CAR Contractor shall include: experience and personnel to prepare contamination assessment
plans, conduct contamination assessments, prepare site assessment reports, implement remedial action plans, risk based corrective
actions or any other type of environmental assessment or remedial activities as necessary.
All the work performed by the CAR Contractor shall be performed in compliance with all applicable local, state and federal regulations
governing worker safety and environmental regulations. This is to include occupational exposure to contaminated soils, groundwater,
wastes and atmosphere during the construction of all features included in the construction plans. In addition, the CAR Contractor must be
staffed with Florida licensed technical professionals (geologists and engineers) who will be involved with the project and howledgeable of
the work activities conducted within the identified contaminated areas and who would sign and seal project reports as required for
submittal to the appropriate environmental regulatory agencies.
The City of Key West Engineer will immediately notify the Florida Department of Transportation (FDOT) District VI Contamination Impact
Coordinator (DCIC) at (305) 470-5228 after encountering the unidentified areas of contamination. Preliminary investigation by the CAR
Contractor will determine the course of action necessary for site security and the steps necessary under applicable laws, rules, and
regulations for additional assessment and/or remediation work to resolve the contamination issue.
DIVISION 4 - MASONRY
1. SCOPE: FURNISH AND INSTALL ALL LABOR, MATERIALS, EQUIPMENT AND SERVICE NECESSARY TO COMPLETE ALL
MASONRY WORK AS INDICATED OR SPECIFIED.
2. RELATED WORK SPECIFIED ELSEWHERE: MASONRY WALL INSULATING AND FILL, FACE CAULKING OF CONTROL
JOINTS.
3. MATERIALS: CONCRETE MASONRY UNITS SHALL CONFORM TO ASTM C-90, GRADE U-1, FC M=1350 P.S.I.
4. CONSTRUCTION AND WORKMANSHIP:
4.1 THE WORK SHALL BE DONE BY EXPERIENCED MECHANICS, SKILLED IN THEIR TRADE, IN A FIRST CLASS MANNER.
4.2 THE CONTRACTOR SHALL BE RESPONSIBLE FOR QUALITY OF WORKMANSHIP AND FOR COMPLIANCE WITH THE
DESIGN AND SPECIFICATIONS. HE SHALL CORRECT ALL ERRORS AND DEVIATIONS AS REQUESTED BY THE ARCHITECT.
4.3 TRANSPORT AND HANDLE ALL MASONRY UNITS IN SUCH MANNER AS TO PREVENT CHIPPING AND BREAKAGE.
PROTECT ALL MASONRY FROM INCLEMENT WEATHER EFFECTS AND HEAVY AND UNNECESSARY TRAFFIC.
4.4 DO NOT LAY CHIPPED CRACKED OR OTHERWISE DEFECTIVE UNITS IN THE WALL
4.5 ALL JOINTS SHALL BE AS INDICATED ON DRAWINGS, STRAIGHT, TRUE, AND UNIFORM IN THICKNESS TO COURSE
VERTICALLY TO 8 .
4.6 ALL MASONRY SHALL BE RUNNING BOND UNLESS INDICATED OTHERWISE.
4.7 PROVIDE ALL OPENINGS IN MASONRY WALLS WHERE REQUIRED OR INDICATED. BUILD IN ALL ITEMS AS REQUIRED
FOR A COMPLETE JOB, INCLUDING (BUT NOT LIMITED TO) REINFORCING STEEL, BOLTS, ANCHORS, CONDUITS AND
PIPING.
4.8 CLEAN ALL FINISHED MASONRY WALLS FOR A NEAT CLEAN AND FINISHED APPEARANCE, IF EXPOSED TO VIEW.
4.9 INSTALL HORIZONTAL JOINT REINFORCEMENT IN WALL JOINTS AT 16" ON CENTER VERTICAL.
DIVISION 6 - CARPENTRY AND MILLWORK:
EXTENDED
CONCRETE EPOXY COATING TO MATCH EXISTING COLOR,
TEXTURE AND APPLICATION
NOTE: ENTITE PROJECT TO BE PROTECTED VIA IMPLIMENTATION OF A TURBIDITY BARRIER
AND ENVIORMENTAL PROTECTION PLAN AS REQUIRED BY LOCAL, STATE AND FEDEWRAL LAW
A
ENVIORMENTAL NOTES
GENERAL SPECS.
TURBIDITY BARRIER NOTES AND SPECIFICATIONS
DRAWING TITLE:
DIVISION 16 - ELECTRICAL
1. SCOPE: FURNISH, INSTALL AND CONNECT COMPLETE ELECTRICAL SYSTEMS AS SHOWN ON THE DRAWINGS,
SPECIFIED OR OTHERWISE NECESSITATED BY THE WORK, INCLUDING, BUT NOT NECESSARILY LIMITED TO:ELECTRICAL
SERVICE ENTRANCE AND METERING, COMPLETE ELECTRIC DISTRIBUTION SYSTEM FOR LIGHTING AND POWER, WIRING
AND RELATED WORK FOR: MECHANICAL SYSTEMS, MOTORS, PUMPS, TELEPHONE, CABLE T.V. ROUGH IN, AND EQUIPMENT.
2. RELATED WORK SPECIFIED ELSEWHERE: EXCAVATION, FILLING AND BACKFILLING, MECHANICAL AND PLUMBING
3. CONSTRUCTION AND WORKMANSHIP: ALL WORK AND MATERIALS SHALL COMPLY WITH THE FOLLOWING ASMINIMUM STANDARDS.
A.THE NATIONAL ELECTRIC CODE, LATEST EDITION
B.THE NATIONAL ELECTRIC MANUFACTURERS ASSOCIATION STANDARDS
C.THE NATIONAL ELECTRICAL SAFETY CODE
D.THE INSULATED POWER CABLE ENGINEERS ASSOCIATION STANDARDS
E.UNDERWRITERS LABORATORIES INCORPORATED STANDARDS
4 GENERAL REQUIREMENTS
4.1 ALL OUTLETS SHALL BE GROUNDED
4.2 ALL WORK SHALL BE CONCEALED.
4.3 ALL GROUNDING SHALL BE IN ACCORDANCE WITH THE NATIONAL ELECTRIC CODE. GROUND ROD AND ASSEMBLY SUPPLIED AND
INSTALLED BY CONTRACTOR
4.4 LIGHTING FIXTURES, EQUIPMENT, ETC., SHALL BE AS SCHEDULED OR OTHERWISE INDICATED ON THE DRAWINGS.
4.5 THE CONTRACTOR SHALL GUARANTEE THE ENTIRE INSTALLATION (EXCEPT LAMPS) FOR A PERIOD OF ONE (1) YEAR FROM THE
DATE OF FINAL ACCEPTANCE.
4.6 MATERIALS AND EQUIPMENT SHALL COMPLY WITH THE APPLICABLE CURRENT STANDARDS OF UNDERWRITERS LABORATORIES
INC.:
PANELS: SQUARE "D" OR EQUAL PANELS WITH RAIN TIGHT ENCLOSURE WHEN USED OUTDOORS.
ROMEX 12-2 WITH GROUND AND METAL BOXES ARE PERMITTED, UNLESS OTHERWISE SPECIFIED ON THE DRAWINGS. INSTAL WITH
METAL CONDUIT
FEEDERS TO BE (2) 1/0 THW W/ (1) THW IN 4" CONDUIT. OR AS NOTED ON DRAWINGS
CONDUIT TO BE P.V.C. PROVIDE STUB ONLY.
WIRING DEVICES SHALL BE LEVITON, RESIDENTIAL GRADE WHITE, OR APPROVED EQUAL.
4.7 CONTRACTOR SHALL FURNISH LIGHTING FIXTURES AND FANS IN CONTRACT AS CALLED FOR ON THE FIXTURE SCHEDULE SHOWN
ON THE DRAWINGS. IN THE ABSENCE OF A FIXTURE SCHEDULE,. FIXTURES WILL BE AS SELECTED BY THE OWNER AND PAID BY THE
OWNER AS A NEGOTIATED EXTRA TO THE CONTRACT. THE OWNER RESERVES THE RIGHT TO FURNISH FIXTURES SHOWN FOR
INSTALLATION IN LIEU OF PURCHASING THEM THROUGH THE CONTRACTOR.
4.8 CONTRACTOR SHALL FURNISH AND INSTALL APPROVED HARD-WIRED SMOKE DETECTORS IN ACCORDANCE WITH THE
REQUIREMENTS
PROJECT NUMBER:
16.23
DRAWN: KM/TSN
CHECKED: PMP
DATE: 09-19-2016
SHEET #
A-6
7
6
5
4
3
2
1
For Permitting Only Not For Construction
Copyright 2016
1. SCOPE: ALL ROUGH AND FINISH CARPENTRY WORK AND MILL WORK AS INDICATED ON DRAWINGS AND SPECIFIED.
THE INSTALLATION OF ALL ROUGH AND FINISH HARDWARE, SHELVING AND TRIM, HANGER AND ALL MATERIAL
NECESSARY TO COMPLETE ALL THE FRAMING AND FINISH WORK AS SHOWN . INSTALL ALL BLOCKING, FIRE STOPS,
BACKING, BRIDGING, ETC., FOR THE PROPER INSTALLATION OF ALL APPLIED ITEMS.
2. RELATED WORK SPECIFIED ELSEWHERE: FINISHES.
Following completion of the project, the CAR Contractor shall be required to provide copies of all reports submitted to regulatory
agencies, waste material profiles, manifests and/or disposal receipts for the handling of all contaminated media including but not limited to
ground water, waste water, soils, solid wastes, sludge, hazardous wastes, air monitoring records and sample results for all materials
tested and analyzed to the City of Key West Engineer and the FDOT DCIC.
OF 6
PETER M. PIKE FLA. REGISTRATION # AR0015198
LIST OF KNOWN AND POTENTIAL CONTAMINATED SITES
ARCHITECTS
PLANNERS
CONSULTANTS
This drawing is the property of
PETER PIKE ARCHITECT
Unless otherwise provided for by
contract, the contents of this drawing
are confidential and shall not be
transmitted to any other party
except as agreed to by
PETER PIKE ARCHITECT
Based on a desktop review of DERM and FDEP GIS layers, there are (2) facilities with known contamination within a 300-ft buffer of the
project (see list below). Due to the scope of this project and the location of the facility, a more detailed Phase I (Level I) Environmental Site
Assessment (ESA) is not necessary at this time. Should the project limits or the scope of work change, a Phase I (Level I) ESA and
subsequent Phase II (Level II) ESA may be necessary. Please include the attached notes addressing unidentified areas of contamination
during construction in the contract plans.
PIKE
ARCHITECTS
NEW EMBARKMENT / DISSEMBARKMENT RAMP
K EY W E S T B I G H T
FERRY TERMINAL
1. THE GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION, AIA DOCUMENT A201, ARE A PART
OF THIS PROJECT. CONTRACTORS WHO ARE NOT FAMILIAR WITH THIS DOCUMENT MAY OBTAIN COPIES
FROM THE ARCHITECT, OR THE OFFICE OF THE AMERICAN INSTITUTE OF ARCHITECTS, MIAMI, FLORIDA.
OWNER MAY SUBSTITUTE CONTRACT FOR CONSTRUCTION OTHER THAN AIA 201.
2. ALL WORK SHALL BE IN STRICT CONFORMITY WITH THE FLORIDA BUILDING CODE, LATEST EDITION,
AND WITH ALL APPLICABLE LAWS, CODES AND ORDINANCES OF THE CITY, COUNTY, STATE, UTILITY
COMPANIES AND ANY OTHER GOVERNING AGENCIES.
3. THE CONTRACT WORK INCLUDES ALL MATERIAL, EQUIPMENT, TOOLS, LABOR AND SERVICES NECESSARY
FOR THE COMPLETION OF THE PROJECT. THE OWNER HAS THE RIGHT TO, AND EXPECTS ALL WORK TO BE
COMPLETED AS EXPEDITIOUSLY AS QUALITY WORKMANSHIP SHALL ALLOW.
4. THE CONTRACTOR SHALL PROCURE AND PAY FOR ALL NECESSARY BUILDING PERMITS AND FOR INSPECTION
SERVICES OF LOCAL AUTHORITIES WHERE REQUIRED BY LAW.
5. NOTIFY ALL UTILITY COMPANIES PRIOR TO EXCAVATION FOR LOCATION OF UNDERGROUND UTILITIES,
AND/OR PROTECTION OR REMOVAL OF OVERHEAD POWER LINES AND POLES.
6. PROVIDE SAFETY BARRICADES, SIGNALS, FENCES, ETC., AS REQUIRED FOR THE SAFE EXECUTION OF
THE WORK.
7. THE OBSERVATION OF THE CONTRACT WORK SHALL BE DONE BY THE PERSON LISTED IN THE CONTRACT
AGREEMENT AS THE ARCHITECT. IN THE CASE THAT NO OBSERVATION BY THE ARCHITECT IS PROVIDED IN
THE CONTRACT, THE FUNCTIONS OF THE ARCHITECT, WHEREVER CALL FOR IN THE SPECIFICATIONS, SHALL
BE EXERCISED BY THE OWNER.
8. THE CONTRACTOR SHALL PROVIDE A TEMPORARY INSTALLATION OF ELECTRIC SERVICE IF SUCH SERVICE
IS NOT AVAILABLE ON SITE.
9. MATERIALS AND LABOR
9.1 SUBMIT SAMPLES TO THE ARCHITECT FOR APPROVAL OF COLOR WHERE REQUIRED.
9.2 ALL WORK SHALL BE PERFORMED IN THE BEST AND MOST PROFESSIONAL MANNER BY MECHANICS SKILLED
IN THEIR RESPECTIVE TRADES.
9.3 WHERE BRAND NAMES OR MANUFACTURERS NAMES APPEAR, THEY ARE USED TO ESTABLISH A QUALITY OF
MATERIAL AND/OR PROCESS. SUBSTITUTIONS WILL BE APPROVED BY THE ARCHITECT IF , IN HIS JUDGMENT,
THEY CONSTITUTE AN EQUAL MATERIAL OR PROCESS.
9.4 ALL TRADES SHALL GUARANTEE ALL WORK TO BE FREE OF DEFECTS IN MATERIALS OR WORKMANSHIP FOR
A PERIOD OF ONE (1) YEAR FROM THE DATE OF FINAL ACCEPTANCE.
9.5 APPLY, INSTALL, CONNECT, ERECT, CLEAN, CONDITION, AND USE ALL MANUFACTURED ARTICLES IN
ACCORDANCE WITH THE MANUFACTURERS INSTRUCTIONS AND AS SHOWN ON THE DRAWINGS. PROVIDE OWNER
WITH ALL GUARANTEES AND MAINTENANCE MANUALS FOR ALL APPLIANCES AND PIECED OF EQUIPMENT
INSTALLED AS A PART OF THE WORK.
10. PERFORMANCE
10.1 BY SUBMITTING A BID, THE BIDDER AGREES AND WARRANTS THAT HE HAS EXAMINED THE DRAWINGS
AND SPECIFICATIONS AND FOUND THAT THEY ARE ADEQUATE FOR THE PROPER COMPLETION OF THE PROJECT.
10.2 NO CLAIMS FOR ANY EXTRA CHARGES WILL BE ALLOWED BECAUSE OF ALLEGED IMPOSSIBILITIES DUE
TO INADEQUATE DRAWINGS OR SPECIFICATIONS.
10.3 THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING FIELD MEASUREMENTS BEFORE ORDERING
MATERIALS AND PREFABRICATED ITEMS. ANY NECESSARY ADJUSTMENTS BETWEEN FIELD MEASUREMENTS
AND DRAWINGS SHALL BE MADE AS PER THE DECISION OF THE ARCHITECT
11. PAYMENTS
PER CONTRACT WITH OWNER
12. INSURANCE
12.1 THE CONTRACTOR SHALL CARRY WORKMEN COMPENSATION INSURANCE TO THE EXTENT REQUIRED BY
LAW AND SHALL MAINTAIN SUCH INSURANCE IN FULL FORCE DURING THE ENTIRE TIME OF THIS CONTRACT.
12.2 THE CONTRACTOR SHALL CARRY COMPREHENSIVE GENERAL AND AUTOMOTIVE LIABILITY INSURANCE
OF $100,000 TO $300,000 (MINIMUM) AND PROPERTY DAMAGE INSURANCE OF $50,000 (MINIMUM).
13. COMPLETION
13.1 ALL WORK SHALL BE SUBSTANTIALLY COMPLETED AT A TIME STIPULATED IN THE CONTRACT AGREEMENT
OR IN TIME EXTENDED FOR JUSTIFIABLE DELAYS, IF ANY.
13.2 A BUILDING OR ANY OTHER WORK SHALL BE CONSIDERED SUBSTANTIALLY COMPLETED WHEN
NINETY-FIVE PERCENT (95%) OF THE WORK IS DONE AND THE BUILDING IS READY FOR OCCUPANCY OR THE
PREMISES FOR USE.
General Comments/Notes to Designer:
B
REVISIONS: DATE
#1
12-29-2016
DIVISION 1 - GENERAL REQUIREMENTS
1. The Contractor shall review environmental requirements of any proposed staging areas with the Miami Dade County Project
Engineer (INSERT PROJECT ENGINEER NAME & NUMBER) at least seventy-two (72) hours prior to use.
2. No staging or any other activities for this project will be allowed within or adjacent to Key West Bight, seagrass beds, or
mangroves except as explicitly shown on the Contract Plans and permitted by the regulatory agencies.
3. Mangroves exist along the shoreline along Trumbo Road. Any trimming or disturbance to mangroves shall comply with Sec
403.9321-9333 F.S., "Mangrove Trimming and Preservation Act"; A Professional Mangrove Trimmer, designated per 403.9329
F.S., shall be present on site throughout the duration of all mangrove trimming or disturbance activities. The Contractor shall
coordinate with the Miami Dade County Project Engineer (LAP AGENCY TO INSERT NAME AND NUMBER FOR
REPRESENTATIVE) at least seventy-two (72) hours in advance to obtain approval for these activities.
4. This project is within the Florida Keys National Marine Sanctuary, which is designated as Outstanding Florida Waters
(OFW). The project must comply with the turbidity requirements of the OFW designation including: no degradation of water
quality; no increased turbidity of the water; and turbidity levels beyond the turbidity control measures cannot exceed 0
Nephelometric Turbidity Units (NTUs) above background levels.
5. The following Federal and State listed animal species could inhabit or migrate through the construction area: West Indian
manatee (endangered), piping plover (threatened), marine turtles (endangered), smalltooth sawfish (endangered), roseate tern
(threatened) and American crocodile (threatened). The Contractor shall comply with all Federal and State requirements
regarding endangered and threatened species and State listed species of special concern. Should these species be encountered,
the Contractor shall contact the Miami Dade County Project Engineer (INSERT PROJECT ENGINEER NAME & NUMBER)
within 24 hours of each encounter.
C
1
ARCHITECTURAL SPECIFICATIONS
Environmental Notes:
D
2
471 US HIGHWAY #1
SUITE 101
KEY WEST, FLA. 33040
305-296-1692
6
PROJECT:
7