Home

Jacksonville District

Run scraper

Marina Management Corporation

Basic information

Fill out these two fields at minimum.

— or —

How Big?

Where?

Links to source documents

Raw text

You can copy from here when filling out the rest of the page.

Escambia County. Marina Management Corporation. Pensacola, Florida. PROJECT PURPOSE: Basic: Marina. Overall: Reconfigure an existing commercial docking facility and construct breakwaters, in Pensacola Bay, in Escambia County.

TO WHOM IT MAY CONCERN: The Jacksonville District of the U.S. Army Corps of Engineers (Corps) has received an application for a Department of the Army permit pursuant to Section 404 of the Clean Water Act (33 U.S.C. §1344) and Section 10 of the Rivers and Harbors Act of 1899 (33 U.S.C. §403) as described below:

APPLICANT: Marina Management Corporation

c/o Ray Russenberger, President

850 South Palafox Street, Suite 102

Pensacola, Florida 32502

WATERWAY AND LOCATION: The project would affect waters of the United States associated with Pensacola Bay. The project is located at 600 South Barracks Street, in Section 42, Township 2 South, Range 30 West, in Pensacola, Escambia County, Florida.

Directions to the site are as follows: From Garden Street in downtown Pensacola, turn south on Tarragona Street. Continue to the end of the road, then turn east on Main Street, then immediately turn south on Barracks Street. The project will be located on the east side of the road at 600 South Barracks Street.

APPROXIMATE CENTRAL COORDINATES:

Latitude 30.407156 North

Longitude -87.209799 West

PROJECT PURPOSE:

Basic: Marina

Overall: Reconfigure an existing commercial docking facility and construct breakwaters, in Pensacola Bay, in Escambia County.

EXISTING CONDITIONS: The project site consists of an existing 46-slip marina (permanent and transient mooring) with concrete floating pier, totaling 13,439 square feet of overwater structure. The majority of the shoreline surrounding the site is natural with emergent vegetation to the north and south and portions of the southern shoreline is stabilized with riprap. Water depths range from -7 to -9 ft. The site is surrounded by a park to the north, commercial restaurants to the west, Pensacola Bay to the east, and the Port of Pensacola to the south.

PROPOSED WORK: The applicant seeks authorization to reconfigure the existing commercial marina, and construct two breakwaters. The existing 13,439 square foot structure would be removed. The new structure would total 17,785 square feet and consist of 47 permanent slips and 24 temporary day use slips.

The two proposed breakwaters have a combined footprint of 10,543 square feet and consist of concrete sheet pile and reinforced concrete batter piles with armor stone at the base of the sheet pile. The breakwaters are intended to protect the marina from extreme weather events.

AVOIDANCE AND MINIMIZATION INFORMATION: The applicant has provided the following information in support of efforts to avoid and/or minimize impacts to the aquatic environment: The applicant would minimize impacts to the aquatic environment by utilizing Best Management Practices (BMPs) during construction. No seagrass would be impacted by the proposed work.

COMPENSATORY MITIGATION: The applicant has offered the following compensatory mitigation plan to offset unavoidable functional loss to the aquatic environment: Due to the nature of the project, the applicant did not offer compensatory mitigation.

CULTURAL RESOURCES: The Corps is not aware of any known historic properties within the permit area. By copy of this public notice, the Corps is providing information for review. Our final determination relative to historic resource impacts is subject to review by and coordination with the State Historic Preservation Officer and those federally recognized tribes with concerns in Florida and the Permit Area.

ENDANGERED SPECIES: The Corps has determined the proposed project may affect, but would not likely adversely affect the West Indian manatee (Trichechus manatus) as determined using the 2013 Manatee Key, following couplets A > B > C > G > H > I > J> L > N > O > P. The Corps has also determined the proposed project may affect, but is not likely to adversely affect the Gulf sturgeon (Acipenser oxyrinchus desotoi), Green turtle (Chelonia mydas), Leatherback turtle (Dermochelys coriacea), Kemp’s Ridley turtle (Lepidochelys kempii), and Smalltooth sawfish (Pristis pectinata). The Corps has requested National Marine Fisheries Service concurrence with this determination pursuant to Section 7 of the Endangered Species Act.

ESSENTIAL FISH HABITAT (EFH): This notice initiates consultation with the National Marine Fisheries Service on EFH as required by the Magnuson-Stevens Fishery Conservation and Management Act 1996. The proposal would impact approximately 0.41 acres of estuarine subtidal habitat due to shading and 0.24 acres of estuarine subtidal habitat due to installation of breakwaters utilized by various life stages of 4 shark species (sandbar, scalloped hammerhead, tiger, Atlantic sharpnose), four shrimp species (brown, white, pink, Royal red), coastal migratory pelagic species, red drum, and 43 species of reef fish. Our initial determination is that the proposed action would not have a substantial adverse impact on EFH or Federally managed fisheries. Our final determination relative to project impacts and the need for mitigation measures is subject to review by and coordination with the National Marine Fisheries Service.

NOTE: This public notice is being issued based on information furnished by the applicant. This information has not been verified or evaluated to ensure compliance with laws and regulation governing the regulatory program.

AUTHORIZATION FROM OTHER AGENCIES: Water Quality Certification may be required from the Florida Department of Environmental Protection and/or one of the state Water Management Districts.

COMMENTS regarding the potential authorization of the work proposed should be submitted in writing to the attention of the District Engineer through the Pensacola Permits Section, 41 North Jefferson Street, Suite 301, Pensacola, Florida, 32502 within 30 days from the date of this notice.

The decision whether to issue or deny this permit application will be based on the information received from this public notice and the evaluation of the probable impact to the associated wetlands. This is based on an analysis of the applicant's avoidance and minimization efforts for the project, as well as the compensatory mitigation proposed.

QUESTIONS concerning this application should be directed to the project manager, Holly Millsap, in writing at the Pensacola Permits Section, 41 North Jefferson Street, Suite 301, Pensacola, FL 32502, by electronic mail at Holly.M.Millsap@usace.army.mil, by fax at (850) 433-8160, or by telephone at (850) 470-9823.

IMPACT ON NATURAL RESOURCES: Preliminary review of this application indicates that an Environmental Impact Statement will not be required. Coordination with U.S. Fish and Wildlife Service, Environmental Protection Agency (EPA), the National Marine Fisheries Services, and other Federal, State, and local agencies, environmental groups, and concerned citizens generally yields pertinent environmental information that is instrumental in determining the impact the proposed action will have on the natural resources of the area. By means of this notice, we are soliciting comments on the potential effects of the project on threatened or endangered species or their habitat

EVALUATION: The decision whether to issue a permit will be based on an evaluation of the probable impact including cumulative impacts of the proposed activity on the public interest. That decision will reflect the national concern for both protection and utilization of important resources. The benefits, which reasonably may be expected to accrue from the proposal, must be balanced against its reasonably foreseeable detriments. All factors which may be relevant to the proposal will be considered including cumulative impacts thereof; among these are conservation, economics, esthetics, general environmental concerns, wetlands, historical properties, fish and wildlife values, flood hazards, floodplain values, land use, navigation, shoreline erosion and accretion, recreation, water supply and conservation, water quality, energy needs, safety, food, and fiber production, mineral needs, considerations of property ownership, and in general, the needs and welfare of the people. Evaluation of the impact of the activity on the public interest will also include application of the guidelines promulgated by the Administrator, EPA, under authority of Section 404(b) of the Clean Water Act of the criteria established under authority of Section 102(a) of the Marine Protection Research and Sanctuaries Act of 1972. A permit will be granted unless its issuance is found to be contrary to the public interest.

The US Army Corps of Engineers (Corps) is soliciting comments from the public; Federal, State, and local agencies and officials; Indian Tribes; and other Interested parties in order to consider and evaluate the impacts of this proposed activity. Any comments received will be considered by the Corps to determine whether to issue, modify, condition, or deny a permit for this proposal. To make this decision, comments are used to assess impacts on endangered species, historic properties, water quality, general environmental effects, and the other public interest factors listed above. Comments are used in the preparation of an Environmental Assessment and/or an Environmental Impact Statement pursuant to the National Environmental Policy Act comments are also used to determine the need for a public hearing and to determine the overall public interest of the proposed activity.

COASTAL ZONE MANAGEMENT CONSISTENCY: In Florida, the State approval constitutes compliance with the approved Coastal Zone Management Plan. In Puerto Rico, a Coastal Zone Management Consistency Concurrence is required from the Puerto Rico Planning Board, in the Virgin Islands, the Department of Planning and Natural Resources permit constitutes compliance with the Coastal Zone Management Plan.

REQUEST FOR PUBLIC HEARING: Any person may request a public hearing. The request must be submitted in writing to the District Engineer within the designated comment period of the notice and must state the specific reasons for requesting the public hearing.

THESE SKETCHES ARE FOR PERMIT REVIEW ONLY AND NOT FOR CONSTRUCTION.

Georgia

r le ag

Levy

Marion

Volusia

o Citrus

Su m

Location Map

ter

ic

in nkl

Fra

Fl

Gu l f Of Me x

Liberty Wakulla

s ohn

Project Area

JACKSONVILLE

St. J

Gulf

Leon

bia

h

l Ca

Nassau

Hamilton Madison Duval SuwanBaker nee Taylor LafayBrad- Clay ette ford GilcDixe hrist Alachua Putnam lum

n ou

Gadsden

Co

Bay

PENSACOLA

TALLAHASSEE

Jackson

on

Washington

Walton

ffe rs

Holmes

Je

Santa Rosa

sa

m a

o alo Ok

mbia Esca

Al ab a

Lake

N.T.S.

ORLANDO

Seminole

Hernando

Orange

Pinellas

County Santa R osa Co unty

Escam bia 4

5

6

29'

8

9 10

10

Mooring Pile

21 23

19

650 12

11

13 14 11 12 461

433'

25 27

16

15

14

13

17

22 24

19

28 30 32

45

44

43

24

22

25 30

34 36

42

2541

45 47

41 43

37 39

21

43' 51

40

100 46

20

23

24

42'

29

77

27

26 28

100'

47

33 35

29 31

10 638

20 Mooring 122

53

18

26

17 18 15 16

300' Alongside

4

49 51

53 157'

55

57

59

126'

40'

25

43'

88

88 42' 44'

32

62'

33

120'

56

Limit

9

656

7

Existing Docks Proposed Access Ramps 10'

60

54 50 34 42 44 46 48Floating Docks Existing (to be removed) 149° Finger Pier 52

58

95'

38 31 40

60'

149'

47

40

39

38

Lease

7 25 8

6

5

4

10'77'

37

36

35

85'

35

57'

13'

385

Project Area

Lee

Pensacola Bay

Hendry

Palm Beach

Broward

Collier

US 98

Martin

Glades

Mo

MiamiDade

nro e

e eez f Br Gul rkway Pa

US 98

Turbidity Curtain

Charlotte

St. Lucie

ee

3

50 Proposed 39

Desoto

Highlands

ob ch

26

2

Proposed Breakwaters Proposed Breakwaters

847' 675' 718

22'

1

4'

3

2

1

117'

Hardee

Indian River

ee

Gulf Sturgeon Critical Habitat

Existing MHWL +0.9' NAVD88

Proposed Floating Dock

Existing Ramps (to be removed and replaced)

Manatee Sa ra so ta

Osceola Polk Ok

TAMPA

Hillsborough

ard

Interstate 10

v Bre

Pasco

MIAMI

Street Map

Ba

yf

ro

nt

Pk

y

1" = 20,000'

Pensacola Bay

acks St.

S. Barr

Vicinity Map

Project Area

1" = 1,000'

543 Harbor Boulevard, Suite 204 Destin, Florida 32541 Certification of Authorization Number 9482

mrd associates, inc. Coastal, Marina & Water Resources Engineering

850.654.1555 (voice) 850.654.0550 (fax) www.mrd-associates.com

PROJECT LOCATION

Seville Harbour Breakwaters and Docking Facilities Marina Management Corporation 850 South Palafox Street, Suite 102, Pensacola, Florida 32502

10/04/2016 Michael R. Dombrowski, P.E. Florida P.E. Number 55255

Date: October 04, 2016 Sheet Rev Date: November 09, 2016 PROJECT NUMBER

16-346

SHEET NUMBER

2

THESE SKETCHES ARE FOR PERMIT REVIEW ONLY AND NOT FOR CONSTRUCTION.

Existing MHWL +0.9' NAVD88 -1

City Le

-2

ry ounda

-3

ase B

-4 -5 -6

-7

-8

-9

-9

Existing Floating Docks (to be removed) -8

-8

ase City Le

Existing Ramps (to be removed and replaced)

543 Harbor Boulevard, Suite 204 Destin, Florida 32541 Certification of Authorization Number 9482

mrd associates, inc. Coastal, Marina & Water Resources Engineering

850.654.1555 (voice) 850.654.0550 (fax) www.mrd-associates.com

Bound

ary

10/04/2016

DEMOLITION PLAN

Seville Harbour Breakwaters and Docking Facilities Marina Management Corporation 850 South Palafox Street, Suite 102, Pensacola, Florida 32502

Michael R. Dombrowski, P.E. Florida P.E. Number 55255

Date: October 04, 2016 Sheet Rev Date: November 09, 2016 PROJECT NUMBER

16-346

SHEET NUMBER

4

THESE SKETCHES ARE FOR PERMIT REVIEW ONLY AND NOT FOR CONSTRUCTION.

y

oundar

ase B City Le

D

B

6

12

23

24

32

29 26

33

30

27

28

34

31

D

C'

D

D'

D

7

11

16

20

19

18

C

1

3

5

8

10

15

D'

A

2

4

9

14

13

17

22

21

A'

25

47 45

44

43

42

41

40

38

37

35

36

D'

D'

46

39

B' ase City Le

543 Harbor Boulevard, Suite 204 Destin, Florida 32541 Certification of Authorization Number 9482

mrd associates, inc. Coastal, Marina & Water Resources Engineering

850.654.1555 (voice) 850.654.0550 (fax) www.mrd-associates.com

ry Bounda

NOTE: Docks are 10' wide unless otherwise noted. Finger docks are 4' wide.

FLOATING DOCK PLAN

Seville Harbour Breakwaters and Docking Facilities Marina Management Corporation 850 South Palafox Street, Suite 102, Pensacola, Florida 32502

10/04/2016

Michael R. Dombrowski, P.E. Florida P.E. Number 55255

Date: October 04, 2016 Sheet Rev Date: November 09, 2016 PROJECT NUMBER

16-346

SHEET NUMBER

8

THESE SKETCHES ARE FOR PERMIT REVIEW ONLY AND NOT FOR CONSTRUCTION.

Proposed Electrical Box (Offset From Section Line)

Proposed Power Pedestal (Offset From Section Line)

Proposed Access Ramp

Proposed Concrete Dock Pile

Existing Wood Deck

(Top Elevation TBD, Offset From Section Line)

Existing Railing

0 Pile Embedment Varies

-10

0

10

20

30

40

50

60

70

80

90

100

15 10 5 0 -5 -10 -15 -20 -25

110

120

130

140

150

Distance From Bulkhead (feet)

160

170

East

Proposed Floating Dock (Deck Elevation Varies with Tides)

MATCH LINE A

Elevation (NAVD 1988, feet)

West

(Deck Elevation Varies with Tides)

MATCH LINE A

15 A 10 5 0 -5 -10 -15 -20 -25 -30 -20

Proposed Floating Dock

180

190

West

200

210

220

230

240

250

260

270

280

290

300

310

320

Distance From Bulkhead

330

340

350 10/04/2016 360 370

MATCH LINE B

Elevation (NAVD 1988, feet)

(Top Elevation @ +7.5')

East

(feet)

543 Harbor Boulevard, Suite 204 Destin, Florida 32541 Certification of Authorization Number 9482

mrd associates, inc. Coastal, Marina & Water Resources Engineering

850.654.1555 (voice) 850.654.0550 (fax) www.mrd-associates.com

DOCK SECTION A-A' (1 of 2)

Seville Harbour Breakwaters and Docking Facilities Marina Management Corporation 850 South Palafox Street, Suite 102, Pensacola, Florida 32502

Michael R. Dombrowski, P.E. Florida P.E. Number 55255

Date: October 04, 2016 Sheet Rev Date: November 09, 2016 PROJECT NUMBER

16-346

SHEET NUMBER

9

(Deck Elevation Varies with Tides)

MATCH LINE C

15 10 5 0 -5 -10 -15 -20 -25

Proposed Floating Dock

MATCH LINE B

Elevation (NAVD 1988, feet)

THESE SKETCHES ARE FOR PERMIT REVIEW ONLY AND NOT FOR CONSTRUCTION.

380

390

West

400

410

420

430

440

450

460

470

480

490

500

510

520

530

540

550

560

Distance From Bulkhead

570

East

580

Proposed Breakwater

Proposed Floating Dock (Deck Elevation Varies with Tides)

MHWL +0.90' NAVD 1988

580

MLWL +0.30'

See Sheet 14 590

West

600

610

620

630

640

650

660

670

680

690

700

710

720

Distance From Bulkhead (feet)

543 Harbor Boulevard, Suite 204 Destin, Florida 32541 Certification of Authorization Number 9482

mrd associates, inc. Coastal, Marina & Water Resources Engineering

850.654.1555 (voice) 850.654.0550 (fax) www.mrd-associates.com

15 10 5 0 -5 -10 -15 -20 -25 770

A'

DOCK SECTION A-A' (2 of 2)

Seville Harbour Breakwaters and Docking Facilities Marina Management Corporation 850 South Palafox Street, Suite 102, Pensacola, Florida 32502

730

740

750

760

Elevation (NAVD 1988, feet)

15 10 5 0 -5 -10 -15 -20 -25

MATCH LINE C

Elevation (NAVD 1988, feet)

(feet)

East

10/04/2016 Michael R. Dombrowski, P.E. Florida P.E. Number 55255

Date: October 04, 2016 Sheet Rev Date: November 09, 2016 PROJECT NUMBER

16-346

SHEET NUMBER

10

THESE SKETCHES ARE FOR PERMIT REVIEW ONLY AND NOT FOR CONSTRUCTION.

Proposed Power Pedestal (Offset From Section Line)

Proposed Concrete Dock Pile

(Top Elevation TBD, Offset From Section Line) (Deck Elevation Varies with Tides)

15 B' 10 MHWL +0.90' 5 NAVD 1988 0 MLWL +0.30' -5 -10 -15 -20 -25 120 110 100

North

15 10 5 0 -5 -10 -15 -20 -25 -40

B

Approximate Existing Grade

90

80

70

60

50

Pile Embedment Varies

40

30

20

10

0

-10

-20

Distance From Mean High Water Line

-30

Elevation (NAVD 1988, feet)

Elevation (NAVD 1988, feet)

Proposed Floating Dock

South

(feet)

Existing Bulkhead

543 Harbor Boulevard, Suite 204 Destin, Florida 32541 Certification of Authorization Number 9482

mrd associates, inc. Coastal, Marina & Water Resources Engineering

850.654.1555 (voice) 850.654.0550 (fax) www.mrd-associates.com

DOCK SECTION B-B'

Seville Harbour Breakwaters and Docking Facilities Marina Management Corporation 850 South Palafox Street, Suite 102, Pensacola, Florida 32502

10/04/2016

Michael R. Dombrowski, P.E. Florida P.E. Number 55255

Date: October 04, 2016 Sheet Rev Date: November 09, 2016 PROJECT NUMBER

16-346

SHEET NUMBER

11

THESE DRAWINGS ARE FOR PERMIT REVIEW ONLY AND NOT FOR CONSTRUCTION.

C'

Concrete Dock Pile Floating Pier Finger Piers Width Vaires

D

C

D'

Floating Walkway Width Vaires

Concrete Dock Pile

TYPICAL FLOATING DOCK SCALE: N.T.S.

Varies Deck Height Varies Between 24" And 48" Above MHW Line. 48" to 96" (Typ.)

MHWL

Total Height Will Depend On Desired Distance Above The Water. Larger Boats Will Have Higher Decks.

TYPICAL FLOATING DOCK SECTION (C-C' and D-D') SCALE: N.T.S.

543 Harbor Boulevard, Suite 204 Destin, Florida 32541 Certification of Authorization Number 9482

mrd associates, inc. Coastal, Marina & Water Resources Engineering

850.654.1555 (voice) 850.654.0550 (fax) www.mrd-associates.com

TYPICAL FLOATING DOCK

Seville Harbour Breakwaters and Docking Facilities Marina Management Corporation 850 South Palafox Street, Suite 102, Pensacola, Florida 32502

C:\Civil 3D Projects\MRD\11-346 Seville Harbour Breakwater\2012-07-24 Permit Set 11-346.dwg

Michael R. Dombrowski, P.E. Florida P.E. Number 55255

Date: October 04, 2016 Sheet Rev Date: November 09, 2016 PROJECT NUMBER

16-346

SHEET NUMBER

12

THESE SKETCHES ARE FOR PERMIT REVIEW ONLY AND NOT FOR CONSTRUCTION.

dary e Boun s a e L City

29'

Proposed Breakwaters 126'

24

88 44' 120'

62'

33

30

34

31

28

43'

32

29

27

25

95' oted

en otherwis s s le n ide u NOTE: re 10' we 4' wide a s k c o r D docks a Finger

43

42

41

40

39

38

37

36

149°

85' 10/04/2016

543 Harbor Boulevard, Suite 204 Destin, Florida 32541 Certification of Authorization Number 9482

Coastal, Marina & Water Resources Engineering

149'

35

35

mrd associates, inc.

ndary

20

21

23

se Bou

19

22

a City Le

157'

850.654.1555 (voice) 850.654.0550 (fax) www.mrd-associates.com

57' PROPOSED BREAKWATER PLAN

Seville Harbour Breakwaters and Docking Facilities Marina Management Corporation 850 South Palafox Street, Suite 102, Pensacola, Florida 32502

Michael R. Dombrowski, P.E. Florida P.E. Number 55255

Date: October 04, 2016 Sheet Rev Date: November 09, 2016 PROJECT NUMBER

16-346

SHEET NUMBER

13

THESE SKETCHES ARE FOR PERMIT REVIEW ONLY AND NOT FOR CONSTRUCTION.

2' X 5' Concrete Cap Top of Cap +6.0' NAVD88 Top of Wall Panel +5.0' NAVD88 Concrete Panel

Mean High Water Top of Armor Stone -1.0' NAVD88

1 2

Bottom of Wall Panel -4.0' NAVD88

Armor Stone

2

1

Existing Sea Floor Bottom -6.0' NAVD88

Concrete Batter Pile @ 8' O.C.

12' 7'

Minimum Tip Elevation Varies Concrete "H" Pile @ 8' O.C. With Concrete Panel

SECTION E-E' SCALE: 1" = 5'

10/04/2016

543 Harbor Boulevard, Suite 204 Destin, Florida 32541 Certification of Authorization Number 9482

mrd associates, inc. Coastal, Marina & Water Resources Engineering

850.654.1555 (voice) 850.654.0550 (fax) www.mrd-associates.com

BREAKWATER SECTION E-E'

Seville Harbour Breakwaters and Docking Facilities Marina Management Corporation 850 South Palafox Street, Suite 102, Pensacola, Florida 32502

Michael R. Dombrowski, P.E. Florida P.E. Number 55255

Date: October 04, 2016 Sheet Rev Date: November 09, 2016 PROJECT NUMBER

16-346

SHEET NUMBER

14

THESE SKETCHES ARE FOR PERMIT REVIEW ONLY AND NOT FOR CONSTRUCTION.

2' X 5' Concrete Cap Top of Cap +6.0' NAVD88 Top of Wall Panel +5.0' NAVD88 Concrete Panel

Mean High Water Top of Armor Stone -1.0' NAVD88

1 2

2 Bottom of Wall Panel -4.0' NAVD88

Concrete Batter Pile @ 8' O.C.

1 Armor Stone

Existing Sea Floor Bottom -6.0' NAVD88

8.5'

18' Minimum Tip Elevation Varies

Concrete "H" Pile @ 8' O.C. With Concrete Panel

SECTION F-F' SCALE: 1" = 5'

10/04/2016

543 Harbor Boulevard, Suite 204 Destin, Florida 32541 Certification of Authorization Number 9482

mrd associates, inc. Coastal, Marina & Water Resources Engineering

850.654.1555 (voice) 850.654.0550 (fax) www.mrd-associates.com

BREAKWATER SECTION F-F'

Seville Harbour Breakwaters and Docking Facilities Marina Management Corporation 850 South Palafox Street, Suite 102, Pensacola, Florida 32502

Michael R. Dombrowski, P.E. Florida P.E. Number 55255

Date: October 04, 2016 Sheet Rev Date: November 09, 2016 PROJECT NUMBER

16-346

SHEET NUMBER

15

THESE SKETCHES ARE FOR PERMIT REVIEW ONLY AND NOT FOR CONSTRUCTION.

Mean HIgh Water Line +0.9 feet NAVD88

Turbidity Curtain

PLAN VIEW SCALE: 1" = 200'

Mooring Buoy

Crown Buoy MHW +0.73' NAVD 88

Chain Anchor

Rope

Existing Grade

Silt Screen

10/04/2016

TURBIDITY DETAILS SCALE: N.T.S.

543 Harbor Boulevard, Suite 204 Destin, Florida 32541 Certification of Authorization Number 9482

mrd associates, inc. Coastal, Marina & Water Resources Engineering

850.654.1555 (voice) 850.654.0550 (fax) www.mrd-associates.com

TURBIDITY DETAILS

Seville Harbour Breakwaters and Docking Facilities Marina Management Corporation 850 South Palafox Street, Suite 102, Pensacola, Florida 32502

Michael R. Dombrowski, P.E. Florida P.E. Number 55255

Date: October 04, 2016 Sheet Rev Date: November 09, 2016 PROJECT NUMBER

16-346

SHEET NUMBER

16

THESE SKETCHES ARE FOR PERMIT REVIEW ONLY AND NOT FOR CONSTRUCTION.

NOTES: Drawing referenced to Florida State Plane North, North American Datum of 1983 (NAD 83). Elevations shown hereon are based on North American Vertical Datum of 1988 (NAVD 88). Bathymetric survey performed by MRD Associates, dated September 15, 2011. Construction should not violate State of Florida water quality standards. Indicated berth dimension represents the overall slip and boat length. Materials are subject to change. Pile dimensions will be determined during final design. Aerial photography obtained from Florida Department of Transportation (FDOT) and flown 01-13-2013. The location of all objects in the photograph are approximate and may not represent currently existing conditions. The location of turbidity curtains shown on these drawings is for illustrative purposes only. Turbidity curtains will be located to best assure water quality standards and relocated as construction activities warrant to ensure water quality standards are maintained throughout construction. Fixed Breakwater Total area: 10,543 ft² Materials: Prestressed concrete panels with prestressed soldier concrete piles and Armor Stone. Final material selection will be determined during final design. Floating Concrete Pier Total area: 17,785 ft² of deck area Total length: 1,724 lf of staging docks Mooring Piles Total Qty: Timber mooring piles Materials: Timber mooring piles shall be southern pine, pressure treated with chromated-copper-arsenate (CCA), water bourne preservative, 2.5 pounds dry chemical retention per cubic foot in accordance with AWPA standards C3 and C18. Permanent Slips Total Qty: 47 Slips

543 Harbor Boulevard, Suite 204 Destin, Florida 32541 Certification of Authorization Number 9482

mrd associates, inc.

850.654.1555 (voice) 850.654.0550 (fax) www.mrd-associates.com

Coastal, Marina & Water Resources Engineering

S:\Support\AutoCad\Templates\MRD Standard Templates.dwt

GENERAL NOTES

Seville Harbour Breakwaters and Docking Facilities Marina Management Corporation 850 South Palafox Street, Suite 102, Pensacola, Florida 32502

Date: October 04, 2016 Sheet Rev Date: November 09, 2016 PROJECT NUMBER

16-346

SHEET NUMBER

17

Rough impact

We use the fields in this section to decide whether to conduct an in-depth review.

Permit Manager

Dates

Identity numbers

Permits, certifications, and locations related to this particular notice

History of edits

Data are available as CSV download in the following schemas