You can copy from here when filling out the rest of the page.
EXPANSION OF A RESIDENTIAL SUBDIVISION IN ASCENSION PARISH
NAME OF APPLICANT: Kelly C. Sills, LLC, c/o D&S Environmental Services, Inc., Attn: David Templet; Post Office Box 510, French Settlement, Louisiana 70733
LOCATION OF WORK: Within the Lake Pontchartrain Basin, in the Lake Maurepas hydrologic unit (HUC 08070204); north of Highway 931 (Germany Road), approximately 0.57 mile east of its intersection with US Highway 61 (Airline Highway), near Prairieville, Louisiana, in Ascension Parish, as shown on the enclosed drawings.
CHARACTER OF WORK: Modify existing permit to allow for construction of Phase 2 of Germany Oaks Subdivision. The applicant proposes to clear, grade, and fill a 23.29-acre site to construct an additional 75 residential lots with pertinent houses, driveways, green space, common areas, and ingress/egress. The applicant proposes to fill approximately 2.54 acres of forested wetlands and 0.3 acre of jurisdictional waters and excavate an additional 0.26 acre of forested wetlands and 0.04 acre of jurisdictional waters. As ompensation for unavoidable wetland impacts the applicant proposes to purchase wetland credits from a Corps approved mitigation bank located in the watershed.
The applicant has designed the development to avoid and minimize direct and secondary adverse impacts to the maximum extent practicable. Any further reduction would limit usage of the property and, therefore function deeming the project impracticable. During construction, appropriate erosion control methods (BMP’s), such as silt fencing, hay bales, seeding, etc., will be utilized to prevent erosion and degradation of water quality or non-point source pollution on-site.
JOINT PUBLIC NOTICE
April 10, 2017
United States Army Corps of Engineers
New Orleans District
Regulatory Branch
7400 Leake Avenue
New Orleans, Louisiana 70118
State of Louisiana
Department of Environmental Quality
Office of Environmental Services
Post Office Box 4313
Baton Rouge, Louisiana 70821-4313
(504) 862-2675
Project Manager
Jamie Crowe
Jamie.M.Crowe@usace.army.mil
Permit Application Number
MVN 2014-01697 CO
(225) 219-3225
Project Manager
Elizabeth Hill
WQC Application Number
WQC 170328-03
Interested parties are hereby notified that a permit application has been received by
the New Orleans District of the U.S. Army Corps of Engineers pursuant to:
[ ] Section 10 of the Rivers and Harbors Act of March 3, 1899 (30 Stat. 1151; 33 USC
403); and/or [X] Section 404 of the Clean Water Act (86 Stat. 816; 33 USC 1344).
Application has also been made to the Louisiana Department of Environmental
Quality, Office of Environmental Services, for a Water Quality Certification (WQC) in
accordance with statutory authority contained in LRS30:2047 A(3), and provisions of
Section 401 of the Clean Water Act (P.L.95-17).
EXPANSION OF A RESIDENTIAL SUBDIVISION IN ASCENSION PARISH
NAME OF APPLICANT: Kelly C. Sills, LLC, c/o D&S Environmental Services, Inc., Attn:
David Templet; Post Office Box 510, French Settlement, Louisiana 70733.
LOCATION OF WORK: Within the Lake Pontchartrain Basin, in the Lake Maurepas
hydrologic unit (HUC 08070204); north of Highway 931 (Germany Road), approximately
0.57 mile east of its intersection with US Highway 61 (Airline Highway), near Prairieville,
Louisiana, in Ascension Parish, as shown on the enclosed drawings.
CHARACTER OF WORK: Modify existing permit to allow for construction of Phase 2
of Germany Oaks Subdivision. The applicant proposes to clear, grade, and fill a 23.29acre site to construct an additional 75 residential lots with pertinent houses, driveways,
green space, common areas, and ingress/egress. The applicant proposes to fill
approximately 2.54 acres of forested wetlands and 0.3 acre of jurisdictional waters and
excavate an additional 0.26 acre of forested wetlands and 0.04 acre of jurisdictional
waters. As compensation for unavoidable wetland impacts the applicant proposes to
purchase wetland credits from a Corps approved mitigation bank located in the
watershed.
The applicant has designed the development to avoid and minimize direct
and secondary adverse impacts to the maximum extent practicable. Any further
reduction would limit usage of the property and, therefore function deeming the project
impracticable. During construction, appropriate erosion control methods (BMP's), such
as silt fencing, hay bales, seeding, etc., will be utilized to prevent erosion and
degradation of water quality or non-point source pollution on-site.
The comment period for the Department of the Army Permit and the Louisiana
Department of Environmental Quality WQC will close 20 days from the date of this joint
public notice. Written comments, including suggestions for modifications or objections
to the proposed work, stating reasons thereof, are being solicited from anyone having
interest in this permit and/or this WQC request and must be mailed, so as to be
received before or by the last day of the comment period. Letters concerning the Corps
of Engineers permit application must reference the applicant's name and the Permit
Application Number, and be mailed to the Corps of Engineers at the address above,
ATTENTION: REGULATORY BRANCH. The application for this proposed project is on
file with the Louisiana Department of Environmental Quality and may be examined
weekdays between 8:00 a.m. and 4:30 p.m. Copies may be obtained upon payment of
costs of reproduction. Individuals or parties may request an extension of time in which
to comment on the proposed work by writing or e-mailing the Corps of Engineers
Project Manager listed above. Any request must be specific and substantively
supportive of the requested extension, and received by this office prior to the end of the
initial comment period. The Section Chief will review the request and the requestor will
be promptly notified of the decision to grant or deny the request. If granted, the time
extension will be continuous to the initial comment period and, inclusive of the initial
comment period, will not exceed a total of 30 calendar days. Letters concerning the
Water Quality Certification must reference the applicant's name and the WQC
Application number and be mailed to the Louisiana Department of Environmental
Quality at the address above.
Corps of Engineers Permit Criteria
The decision whether to issue a permit will be based on an evaluation of the
probable impacts, including cumulative impacts of the proposed activity on the public
interest. That decision will reflect the national concern for both protection and utilization
of important resources. The benefit which reasonably may be expected to accrue from
the proposal must be balanced against its reasonably foreseeable detriments. All
factors which may be relevant to the proposal will be considered including the
cumulative effects thereof; among those are conservation, economics, aesthetics,
general environmental concerns, wetlands, historic properties, fish and wildlife values,
flood hazards, floodplain values, land use, navigation, shoreline erosion and accretion,
recreation, water supply and conservation, water quality, energy needs, safety, food and
fiber production, mineral needs, considerations of property ownership and, in general,
the needs and welfare of the people.
The U.S. Army Corps of Engineers is soliciting comments from the public, federal,
state, and local agencies and officials, Indian Tribes, and other interested parties in
order to consider and evaluate the impacts of this proposed activity. Any comments
received will be considered by the U.S. Army Corps of Engineers to determine whether
to make, modify, condition, or deny a permit for this proposal. To make this decision,
comments are used to assess impacts on endangered species, historic properties,
water quality, general environmental effects, and other public interest factors listed
above. Comments are used in the preparation of an Environmental Assessment and/or
an Environmental Impact Statement pursuant to the National Environmental Policy Act.
Comments are also used to determine the need for a public hearing and to determine
the overall public interest of the proposed activity.
The New Orleans District is unaware of properties listed on the National Register of
Historic Places near the proposed work. The possibility exists that the proposed work
may damage or destroy presently unknown archeological, scientific, prehistorical,
historical sites, or data. Copies of this notice are being sent to the State Archeologist
and State Historic Preservation Officer.
Our initial finding is that the proposed work would not affect any species, nor affect
any habitat designated as critical to the survival and recovery of such species, listed as
endangered by the U.S. Department of Commerce.
Our initial finding is that the proposed work would neither affect any species listed
as endangered by the U.S. Departments of Interior or Commerce, nor affect any habitat
designated as critical to the survival and recovery of any endangered species.
This notice initiates the Essential Fish Habitat (EFH) consultation requirements of the
Magnuson-Stevens Fishery Conservation and Management Act. The applicant's
proposal would result in the destruction or alteration of n/a acres of EFH utilized by
various life stages of red drum and penaeid shrimp. Our initial determination is that the
proposed action would not have a substantial adverse impact on EFH or federally
managed fisheries in the Gulf of Mexico. Our final determination relative to project
impacts and the need for mitigation measures is subject to review by and coordination
with the National Marine Fisheries Service.
If the proposed work involves deposits of dredged or fill material into navigable
waters, the evaluation of the probable impacts will include the application of guidelines
established by the Administrator of the Environmental Protection Agency. Also, a
certification that the proposed activity will not violate applicable water quality standards
will be required from the Department of Environmental Quality, Office of Environmental
Services, before a permit is issued.
Any person may request, in writing, within the comment period specified in this
notice, that a public hearing be held to consider this application. Requests for public
hearings shall state, with particularity, the reasons for holding a public hearing. You are
requested to communicate the information contained in this notice to any other parties
whom you deem likely to have interest in the matter.
You are requested to communicate the information contained in this notice to any
other parties whom you deem likely to have interest in the matter.
John M. Herman
Chief, Central Evaluation Section
Regulatory Branch
Enclosure
(BRAUD RD)
(DAIGLE RD)
INTER
LA HWY 930
LA HWY 929
JAMES DR
COUNTY DR
10
STATE
(GERMANY RD)
LA HWY 931
LA HWY 44
LA HW
Y 73
DUPLESSIS RD
SITE LOCATION
U
WILLIAM FLICKLIN RD
Y
W
.H
.S
61
LA HWY 621
LA HWY 934
LA HWY 74
3,000'
0
3,500'
Scale: 1'' = 3,000'
Notes
Kelly C. Sills, L.L.C.
Germany Oaks, Phase 2
Vicinity Map
Property is located in Section 6, T9S-R3E
Ascension Parish, Louisiana
Reference
Base map comprised of U.S.G.S. 7.5 minute topographic map "Prairieville, LA".
07-2017-DOA
02-22-2017
1
C
Property Boundary (23.29 Acres)
JURISDICTIONAL WETLANDS
TO BE EXCAVATED (RELOCATED
OTHER WATERS OF THE U.S.)
~~~~~ RESIDENCE~~~~
~~~~~ RESIDENCE~~~~
BLACK BAYOU LATERAL DITCH
B
Legend
888'
C'
Non-Wetlands (20.13 Acres)
Other Waters Of The U.S. To Be Impacted By
Construction (0.02 Acres)
104
103
116
158
157
The proposed layout was provided by Quality Engineering & Surveying, L.L.C.
2.
Jurisdictional Wetlands and Other Waters Of The U.S. obtained from U.S. Army
CORPS of Engineers Preliminary Jurisdictional Determination Account Number
MVN-2016-00284-SK.
161
156
162
STORMWATER
DETENTION
POND
(POND 2)
155
163
117
118
119
Germany Oaks, Phase 2
Overall Plan View
153
121
165
122
152
100
166
123
172
171
170
169
168
167
124
PARK OAK AVENUE
125
PARK OAK AVENUE
126
132
131
130
129
128
127
151
100'
150
139
149
133
134
135
136
137
138
142
141
148
SHUMARD OAK DRIVE
RESIDENCE
147
146
145
0.57 mi To
U.S. Hwy 61
144
140
1.29 mi To
Hwy 44
684'
LA HWY 931 (GERMANY ROAD)
200'
143
0
Horizontal Scale: 1'' = 200'
B'
Ascension Parish, Louisiana
2
120
164
377'
Kelly C. Sills, L.L.C.
101
98
~~~~~ GERMANY OAKS SUBDIVISION~~~~
(PHASE 1)
2,969.83 Cubic Yards of Earthen Material.
848.40 Cubic Yards of Soil Cement Base.
586.89 Cubic Yards of Concrete
66.71 Cubic Yards of Asphaltic Concrete
154
104'
784'
Total Proposed Fill
102
99
GERMANY OAKS BLVD.
Wetland Impacts by habitat type:
> Bottomland Hardwood = 2.21 Acres
> Herbaceous = 0.59 Acres
02-22-2017
160
A'
EXISTING
STORMWATER
DETENTION
POND
According to F.E.M.A. F.I.R.M. Community Panel No. 22005C0040 E Dated
8-16-07, this property falls in Flood Zone X (Other Areas; Areas Determined to be
outside 0.2% annual chance flood plain). Nearest Base Flood Elevation = 17.0'
N.G.V.D.
07-2017-DOA
159
~~~~~ RESIDENCE~~~~
105
~~~~~ RESIDENCE~~~~
1.
Approximately
Approximately
Approximately
Approximately
PARK OAK AVENUE
A
Notes
4.
115
106
898'
Other Waters Of The U.S. To Be Excavated (0.04 Acres)
114
113
111
PARK OAK AVENUE
Other Waters Of The U.S. To Be Filled (0.30 Acres)
112
110
109
108
SHUMARD OAK DRIVE
Total Other Waters Of The U.S. (0.36 Acres)
EXPANDED STORMWATER
DETENTION POND
Jurisdictional Wetlands To Be Excavated (0.26 Acres)
496'
STORMWATER
DETENTION
POND
(POND 1)
~~~~~ GERMANY OAKS SUBDIVISION~~~~
(PHASE 1)
Jurisdictional Wetlands To Be Filled (2.54 Acres)
3.
107
EXISTING
STORMWATER
DETENTION
POND
Total Jurisdictional Wetlands (2.80 Acres)
200'
BLACK BAYOU LATERAL DITCH
SECONDARY WEIR
(CONCRETE)
(CREST LENGTH: 80')
C'
2@ 30" POND
OUTFALL PIPES
(EXISTING)
2@24" POND
OUTFALL PIPES
107
109
108
Wetland Impacts by habitat type:
> Bottomland Hardwood = 2.21 Acres
> Herbaceous = 0.59 Acres
PERIMETER DITCH
117
156
118
162
OUTFALL
STRUCTURE
155
103
119
163
A
A'
154
101
153
120
164
165
STORMWATER
DETENTION
POND
(POND 2)
152
100
PARK OAK AVENUE
102
104'
784'
4.
According to F.E.M.A. F.I.R.M. Community Panel No.
22005C0040 E Dated 8-16-07, this property falls in
Flood Zone X (Other Areas; Areas Determined to be
outside 0.2% annual chance flood plain). Nearest
Base Flood Elevation = 17.0' N.G.V.D.
161
121
122
166
123
99
MATCH LINE - SEE FIGURE 4
INGRESS/EGRESS ACCESS
ROAD (ASPHALTIC CONCRETE
WITH CONCRETE CURB &
GUTTER) (TYPICAL)
172
4' CONCRETE
SIDEWALK
(TYPICAL)
Kelly C. Sills, L.L.C.
171
170
169
Legend
168
167
12' DRIVEWAY
(4" CONCRETE) (TYPICAL)
Property Boundary (23.29 Acres)
Non-Wetlands (20.13 Acres)
Total Jurisdictional Wetlands (2.80 Acres)
Germany Oaks, Phase 2
Jurisdictional Wetlands To Be Filled (2.54 Acres)
Jurisdictional Wetlands To Be Excavated (0.26 Acres)
Proposed Plan View
Total Other Waters Of The U.S. (0.36 Acres)
Ascension Parish, Louisiana
Other Waters Of The U.S. To Be Filled (0.30 Acres)
150'
0
150'
Other Waters Of The U.S. To Be Excavated (0.04 Acres)
Horizontal Scale: 1'' = 150'
07-2017-DOA
02-22-2017
3
Other Waters Of The U.S. To Be Impacted By
Construction (0.02 Acres)
RESIDENTIAL HOUSE
(1700 SQ FT)(TYPICAL)
3.
Jurisdictional Wetlands and Other Waters Of The U.S.
obtained from U.S. Army CORPS of Engineers
Preliminary Jurisdictional Determination Account
Number MVN-2016-00284-SK.
~~~~~ GERMANY OAKS SUBDIVISION~~~~
(PHASE 1)
2.
160
~~~~~ RESIDENCE~~~~
SHUMARD OAK DRIVE
104
159
158
157
898'
STORMWATER
DETENTION
POND
(POND 1)
PARK OAK AVENUE
116
105
Notes
The proposed layout was provided by Quality
Engineering & Surveying, L.L.C.
114
113
111
115
24" POND OUTFALL PIPE
EXPANDED STORMWATER
DETENTION POND
496'
Total Proposed Fill
2,969.83 Cubic Yards of Earthen Material.
848.40 Cubic Yards of Soil Cement Base.
586.89 Cubic Yards of Concrete
66.71 Cubic Yards of Asphaltic Concrete
112
110
106
EXISTING
STORMWATER
DETENTION
POND
1.
JURISDICTIONAL WETLANDS
TO BE EXCAVATED (RELOCATED
OTHER WATERS OF THE U.S.)
888'
C
Approximately
Approximately
Approximately
Approximately
~~~~~ RESIDENCE~~~~
B
~~~~~ RESIDENCE~~~~
2,969.83 Cubic Yards of Earthen Material.
848.40 Cubic Yards of Soil Cement Base.
586.89 Cubic Yards of Concrete
66.71 Cubic Yards of Asphaltic Concrete
MATCH LINE - SEE FIGURE 3
STORMWATER
DETENTION
POND
(POND 1)
MATCH LINE - SEE FIGURE 3
169
170
171
172
168
167
98
4' CONCRETE SIDEWALK
(TYPICAL)
123
124
898'
EXISTING INGRESS/EGRESS ACCESS
ROAD (ASPHALTIC CONCRETE
WITH CONCRETE CURB &
GUTTER) (TYPICAL)
PERIMETER
DITCH
RESIDENTIAL HOUSE
(1700 SQ FT)(TYPICAL)
99
PARK OAK AVENUE
151
JURISDICTIONAL
WETLANDS TO BE
EXCAVATED
(PERIMETER
DITCH)
150
126
132
130
131
129
128
127
100'
JURISDICTIONAL
WETLANDS TO BE
EXCAVATED
(PERIMETER
DITCH)
139
149
784'
133
136
135
134
137
138
377'
~~~~~ RESIDENCE~~~~
~~~~~ GERMANY OAKS SUBDIVISION~~~~
(PHASE 1)
GERMANY OAKS BLVD.
125
PARK OAK AVENUE
SHUMARD OAK DRIVE
Approximately
Approximately
Approximately
Approximately
INGRESS/EGRESS ACCESS
ROAD (ASPHALTIC CONCRETE
WITH CONCRETE CURB &
GUTTER) (TYPICAL)
12' DRIVEWAY
(4" CONCRETE)
(TYPICAL)
PARK OAK AVE
Total Proposed Fill
148
SHUMARD OAK DRIVE
147
146
RESIDENCE
143
144
145
142
141
140
RESIDENTIAL HOUSE
(1700 SQ FT)(TYPICAL)
0.57 mi To
U.S. Hwy 61
1.29 mi To
Hwy 44
B'
684'
LA HWY 931 (GERMANY ROAD)
150'
0
150'
Horizontal Scale: 1'' = 150'
Notes
Kelly C. Sills, L.L.C.
1.
The proposed layout was provided by Quality
Engineering & Surveying, L.L.C.
2.
Jurisdictional Wetlands and Other Waters Of The U.S.
obtained from U.S. Army CORPS of Engineers
Preliminary Jurisdictional Determination Account
Number MVN-2016-00284-SK.
Germany Oaks, Phase 2
Legend
Property Boundary (23.29 Acres)
Non-Wetlands (20.13 Acres)
Total Jurisdictional Wetlands (2.80 Acres)
Jurisdictional Wetlands To Be Filled (2.54 Acres)
Proposed Plan View
Jurisdictional Wetlands To Be Excavated (0.26 Acres)
Total Other Waters Of The U.S. (0.36 Acres)
3.
Ascension Parish, Louisiana
4.
07-2017-DOA
02-22-2017
4
According to F.E.M.A. F.I.R.M. Community Panel No.
22005C0040 E Dated 8-16-07, this property falls in
Flood Zone X (Other Areas; Areas Determined to be
outside 0.2% annual chance flood plain). Nearest
Base Flood Elevation = 17.0' N.G.V.D.
Wetland Impacts by habitat type:
> Bottomland Hardwood = 2.21 Acres
> Herbaceous = 0.59 Acres
Other Waters Of The U.S. To Be Filled (0.30 Acres)
Other Waters Of The U.S. To Be Excavated (0.04 Acres)
Other Waters Of The U.S. To Be Impacted By
Construction (0.02 Acres)
~~~~~ GERMANY OAKS SUBDIVISION~~~~
(PHASE 1)
23
PROPERTY
LINE
22
RESIDENTIAL
DRIVEWAY
4" CONCRETE
(TYPICAL)
22
GREEN SPACE
(TYPICAL)
21
21
20
OHWM
19
EXISTING
STORMWATER
DETENTION
POND
15
14
13
EXPANDED
STORMWATER
DETENTION
POND
19
18
17
16
15
14
13
12
12
11
11
10
10
9
9
1.
The proposed layout was provided by Quality Engineering & Surveying, L.L.C.
2.
Jurisdictional Wetlands and Other Waters Of The U.S. obtained from U.S. Army CORPS of
Engineers Preliminary Jurisdictional Determination Account Number MVN-2016-00284-SK.
3.
According to F.E.M.A. F.I.R.M. Community Panel No. 22005C0040 E Dated 8-16-07, this
property falls in Flood Zone X (Other Areas; Areas Determined to be outside 0.2% annual
chance flood plain). Nearest Base Flood Elevation = 17.0' N.G.V.D.
Non-wetland natural ground elevations average 20'-0" N.G.V.D. Elevation data was obtained
from topographic data provided by Quality Engineering & Surveying, L.L.C. Drainage Impact
Study.
Natural Ground elevations in existing jurisdictional wetlands are approximately 6" lower than
non-wetland ground elevations.
7
Horizontal Scale: 1" = 40'
Vertical Scale: 1" = 4'
40'
Notes
8
Section A-A'
7
5.
10" SOIL
CEMENT BASE
(TYPICAL)
OLWM
8
4.
NON-WETLAND
NATURAL GROUND
1'-5"
OTHER WATERS
OF THE U.S. TO BE
EXCAVATED
18
16
EARTHEN
MATERIAL
MATCH LINE - SEE FIGURE 6
Elevation, N.G.V.D.
20
17
23
0
Elevation, N.G.V.D.
A
RESIDENTIAL HOUSE
12" CONCRETE
(TYPICAL)
40'
Horizontal Scale: 1'' = 40'
Kelly C. Sills, L.L.C.
Legend
Earthen Material
Soil Cement Treated Base
Germany Oaks, Phase 2
Section View A-A'
Concrete
Ascension Parish, Louisiana
OHWM
Ordinary High Water Mark
OLWM
Ordinary Low Water Mark
07-2017-DOA
02-22-2017
5
INGRESS/EGRESS ACCESS
3" ASPHALTIC CONCRETE
(TYPICAL)
RESIDENTIAL DRIVEWAY
(4" CONCRETE)(TYPICAL)
23
CURB & GUTTER
6" CONCRETE
(TYPICAL)
RESIDENTIAL HOUSE
12" CONCRETE
(TYPICAL)
RESIDENTIAL
DRIVEWAY
(4" CONCRETE)
(TYPICAL)
23
GREEN SPACE
(TYPICAL)
22
21
22
21
EARTHEN MATERIAL
19
17
16
15
14
13
NON-WETLAND
NATURAL GROUND
JURISDICTIONAL WETLANDS
JURISDICTIONAL WETLANDS
NATURAL GROUND (SEE NOTE 5)
TO BE FILLED
JURISDICTIONAL WETLANDS
JURISDICTIONAL WETLANDS
TO BE FILLED
NATURAL GROUND (SEE NOTE 5)
NON-WETLAND
NATURAL GROUND
STORMWATER
DETENTION
POND
18
17
16
15
14
13
12
12
11
11
10
10
9
9
1.
The proposed layout was provided by Quality Engineering & Surveying, L.L.C.
2.
Jurisdictional Wetlands and Other Waters Of The U.S. obtained from U.S. Army CORPS of
Engineers Preliminary Jurisdictional Determination Account Number MVN-2016-00284-SK.
3.
According to F.E.M.A. F.I.R.M. Community Panel No. 22005C0040 E Dated 8-16-07, this
property falls in Flood Zone X (Other Areas; Areas Determined to be outside 0.2% annual
chance flood plain). Nearest Base Flood Elevation = 17.0' N.G.V.D.
Non-wetland natural ground elevations average 20'-0" N.G.V.D. Elevation data was obtained
from topographic data provided by Quality Engineering & Surveying, L.L.C. Drainage Impact
Study.
7
Horizontal Scale: 1" = 40'
Vertical Scale: 1" = 4'
40'
Notes
8
Section A-A'
7
5.
JURISDICTIONAL WETLANDS
NATURAL GROUND (SEE NOTE 5)
10" SOIL CEMENT
BASE (TYPICAL)
8
4.
JURISDICTIONAL WETLANDS
TO BE EXCAVATED
MATCH LINE - SEE FIGURE 7
18
19
10" SOIL CEMENT
BASE (TYPICAL)
0
Elevation, N.G.V.D.
20
MATCH LINE - SEE FIGURE 5
Elevation, N.G.V.D.
20
40'
Horizontal Scale: 1'' = 40'
Kelly C. Sills, L.L.C.
Legend
Earthen Material
Soil Cement Treated Base
Concrete
Germany Oaks, Phase 2
Section View A-A'
(Continued)
Ascension Parish, Louisiana
Asphaltic Concrete
Natural Ground elevations in existing jurisdictional wetlands are approximately 6" lower than
non-wetland ground elevations.
07-2017-DOA
02-22-2017
6
GREEN SPACE
(TYPICAL)
23
GREEN SPACE
(TYPICAL)
22
CURB & GUTTER
6" CONCRETE
(TYPICAL)
SIDEWALK
(4"CONCRETE)
(TYPICAL)
RESIDENTIAL
DRIVEWAY
(4" CONCRETE)
(TYPICAL)
RESIDENTIAL HOUSE
12" CONCRETE
(TYPICAL)
GREEN SPACE
(TYPICAL)
PROPERTY LINE
INGRESS/EGRESS ACCESS
3" ASPHALTIC CONCRETE
(TYPICAL)
21
14
13
19
NON-WETLAND
NATURAL GROUND
NON-WETLAND
NATURAL GROUND
16
15
14
13
12
12
11
11
10
10
9
9
1.
The proposed layout was provided by Quality Engineering & Surveying, L.L.C.
2.
Jurisdictional Wetlands and Other Waters Of The U.S. obtained from U.S. Army CORPS of
Engineers Preliminary Jurisdictional Determination Account Number MVN-2016-00284-SK.
3.
According to F.E.M.A. F.I.R.M. Community Panel No. 22005C0040 E Dated 8-16-07, this
property falls in Flood Zone X (Other Areas; Areas Determined to be outside 0.2% annual
chance flood plain). Nearest Base Flood Elevation = 17.0' N.G.V.D.
Non-wetland natural ground elevations average 20'-0" N.G.V.D. Elevation data was obtained
from topographic data provided by Quality Engineering & Surveying, L.L.C. Drainage Impact
Study.
7
Horizontal Scale: 1" = 40'
Vertical Scale: 1" = 4'
40'
Notes
8
Section A-A'
7
5.
17
STORMWATER
DETENTION
POND
8
4.
18
10" SOIL CEMENT
BASE (TYPICAL)
0
Elevation, N.G.V.D.
Elevation, N.G.V.D.
15
MATCH LINE - SEE FIGURE 6
16
22
20
EARTHEN
MATERIAL
19
17
23
21
20
18
A'
40'
Horizontal Scale: 1'' = 40'
Kelly C. Sills, L.L.C.
Legend
Earthen Material
Soil Cement Treated Base
Concrete
Germany Oaks, Phase 2
Section View A-A'
(Continued)
Ascension Parish, Louisiana
Asphaltic Concrete
Natural Ground elevations in existing jurisdictional wetlands are approximately 6" lower than
non-wetland ground elevations.
07-2017-DOA
02-22-2017
7
PROPERTY LINE
INGRESS/EGRESS ACCESS
3" ASPHALTIC CONCRETE
(TYPICAL)
B
23
22
GREEN SPACE
(TYPICAL)
CURB & GUTTER
6" CONCRETE
(TYPICAL)
SIDEWALK
(4"CONCRETE)
(TYPICAL)
GREEN SPACE
(TYPICAL)
RESIDENTIAL HOUSE
12" CONCRETE
(TYPICAL)
SIDEWALK
(4"CONCRETE)
(TYPICAL)
23
GREEN
SPACE
(TYPICAL)
GREEN
SPACE
(TYPICAL)
21
22
21
NON-WETLAND
NATURAL
GROUND
18
17
16
15
OHWM
1'-5"
JURISDICTIONAL WETLANDS
NATURAL GROUND (SEE NOTE 5)
OLWM
DITCH
(RELOCATED
OTHER WATERS
OF THE U.S.)
19
10" SOIL CEMENT
BASE (TYPICAL)
NON-WETLAND
NATURAL
GROUND
OTHER WATERS
OF THE U.S. TO BE
FILLED AND RELOCATED
14
13
18
17
16
15
14
13
12
12
11
11
10
10
9
9
1.
The proposed layout was provided by Quality Engineering & Surveying, L.L.C.
2.
Jurisdictional Wetlands and Other Waters Of The U.S. obtained from U.S. Army CORPS of
Engineers Preliminary Jurisdictional Determination Account Number MVN-2016-00284-SK.
3.
According to F.E.M.A. F.I.R.M. Community Panel No. 22005C0040 E Dated 8-16-07, this
property falls in Flood Zone X (Other Areas; Areas Determined to be outside 0.2% annual
chance flood plain). Nearest Base Flood Elevation = 17.0' N.G.V.D.
0
40'
Horizontal Scale: 1'' = 40'
Kelly C. Sills, L.L.C.
Legend
Earthen Material
Soil Cement Treated Base
Non-wetland natural ground elevations average 20'-0" N.G.V.D. Elevation data was obtained
from topographic data provided by Quality Engineering & Surveying, L.L.C. Drainage Impact
Study.
Natural Ground elevations in existing jurisdictional wetlands are approximately 6" lower than
non-wetland ground elevations.
7
Horizontal Scale: 1" = 40'
Vertical Scale: 1" = 4'
40'
Notes
8
Section B-B'
7
5.
EARTHEN
MATERIAL
JURISDICTIONAL WETLANDS
TO BE FILLED
8
4.
10" SOIL CEMENT
BASE (TYPICAL)
Elevation, N.G.V.D.
19
20
MATCH LINE - SEE FIGURE 9
Elevation, N.G.V.D.
20
Germany Oaks, Phase 2
Section View B-B'
Concrete
Ascension Parish, Louisiana
Asphaltic Concrete
OHWM
Ordinary High Water Mark
OLWM
Ordinary Low Water Mark
07-2017-DOA
02-22-2017
8
GREEN SPACE
(TYPICAL)
23
23
22
22
EARTHEN
MATERIAL
19
19
18
17
16
15
14
13
JURISDICTIONAL WETLANDS
TO BE EXCAVATED
NON-WETLAND
NATURAL
GROUND
JURISDICTIONAL WETLANDS
NATURAL GROUND (SEE NOTE 5)
STORMWATER
DETENTION
POND
17
16
15
14
13
12
11
11
10
10
9
9
1.
The proposed layout was provided by Quality Engineering & Surveying, L.L.C.
2.
Jurisdictional Wetlands and Other Waters Of The U.S. obtained from U.S. Army CORPS of
Engineers Preliminary Jurisdictional Determination Account Number MVN-2016-00284-SK.
3.
According to F.E.M.A. F.I.R.M. Community Panel No. 22005C0040 E Dated 8-16-07, this
property falls in Flood Zone X (Other Areas; Areas Determined to be outside 0.2% annual
chance flood plain). Nearest Base Flood Elevation = 17.0' N.G.V.D.
Non-wetland natural ground elevations average 20'-0" N.G.V.D. Elevation data was obtained
from topographic data provided by Quality Engineering & Surveying, L.L.C. Drainage Impact
Study.
7
Horizontal Scale: 1" = 40'
Vertical Scale: 1" = 4'
40'
Notes
8
Section B-B'
7
5.
18
12
8
4.
MATCH LINE - SEE FIGURE 10
20
0
Elevation, N.G.V.D.
21
20
MATCH LINE - SEE FIGURE 8
Elevation, N.G.V.D.
21
40'
Horizontal Scale: 1'' = 40'
Legend
Earthen Material
Kelly C. Sills, L.L.C.
Germany Oaks, Phase 2
Section View B-B'
(Continued)
Ascension Parish, Louisiana
Natural Ground elevations in existing jurisdictional wetlands are approximately 6" lower than
non-wetland ground elevations.
07-2017-DOA
02-22-2017
9
23
22
21
21
20
20
18
17
16
15
14
13
10" SOIL CEMENT
BASE (TYPICAL)
NON-WETLAND
NATURAL
GROUND
NON-WETLAND
NATURAL
GROUND
STORMWATER
DETENTION
POND
MATCH LINE - SEE FIGURE 11
19
19
18
17
16
15
14
13
12
11
11
10
10
9
9
8
1.
The proposed layout was provided by Quality Engineering & Surveying, L.L.C.
2.
Jurisdictional Wetlands and Other Waters Of The U.S. obtained from U.S. Army CORPS of
Engineers Preliminary Jurisdictional Determination Account Number MVN-2016-00284-SK.
3.
According to F.E.M.A. F.I.R.M. Community Panel No. 22005C0040 E Dated 8-16-07, this
property falls in Flood Zone X (Other Areas; Areas Determined to be outside 0.2% annual
chance flood plain). Nearest Base Flood Elevation = 17.0' N.G.V.D.
Non-wetland natural ground elevations average 20'-0" N.G.V.D. Elevation data was obtained
from topographic data provided by Quality Engineering & Surveying, L.L.C. Drainage Impact
Study.
7
Horizontal Scale: 1" = 40'
Vertical Scale: 1" = 4'
40'
Notes
8
Section B-B'
7
5.
RESIDENTIAL HOUSE
12" CONCRETE
(TYPICAL)
22
12
4.
CURB & GUTTER
6" CONCRETE
RESIDENTIAL DRIVEWAY
(TYPICAL)
(4" CONCRETE) (TYPICAL)
SIDEWALK
(4"CONCRETE) (TYPICAL)
MATCH LINE - SEE FIGURE 9
Elevation, N.G.V.D.
23
GREEN SPACE
(TYPICAL)
Elevation, N.G.V.D.
INGRESS/EGRESS ACCESS
3" ASPHALTIC CONCRETE
(TYPICAL)
RESIDENTIAL HOUSE
12" CONCRETE
(TYPICAL)
0
40'
Horizontal Scale: 1'' = 40'
Kelly C. Sills, L.L.C.
Legend
Earthen Material
Soil Cement Treated Base
Concrete
Germany Oaks, Phase 2
Section View B-B'
(Continued)
Ascension Parish, Louisiana
Asphaltic Concrete
Natural Ground elevations in existing jurisdictional wetlands are approximately 6" lower than
non-wetland ground elevations.
07-2017-DOA
02-22-2017
10
GREEN SPACE
(TYPICAL)
RESIDENTIAL
DRIVEWAY
(4" CONCRETE)
(TYPICAL)
RESIDENTIAL HOUSE
12" CONCRETE
(TYPICAL)
GREEN SPACE
(TYPICAL)
20
20
19
18
17
16
15
14
13
19
10" SOIL CEMENT
BASE (TYPICAL)
18
17
NON-WETLAND
NATURAL
GROUND
NON-WETLAND
NATURAL
GROUND
16
15
14
13
12
12
11
11
10
10
9
9
1.
The proposed layout was provided by Quality Engineering & Surveying, L.L.C.
2.
Jurisdictional Wetlands and Other Waters Of The U.S. obtained from U.S. Army CORPS of
Engineers Preliminary Jurisdictional Determination Account Number MVN-2016-00284-SK.
3.
According to F.E.M.A. F.I.R.M. Community Panel No. 22005C0040 E Dated 8-16-07, this
property falls in Flood Zone X (Other Areas; Areas Determined to be outside 0.2% annual
chance flood plain). Nearest Base Flood Elevation = 17.0' N.G.V.D.
Non-wetland natural ground elevations average 20'-0" N.G.V.D. Elevation data was obtained
from topographic data provided by Quality Engineering & Surveying, L.L.C. Drainage Impact
Study.
7
Horizontal Scale: 1" = 40'
Vertical Scale: 1" = 4'
40'
Notes
8
Section B-B'
7
5.
22
21
8
4.
23
21
MATCH LINE - SEE FIGURE 10
Elevation, N.G.V.D.
22
B'
0
Elevation, N.G.V.D.
23
CURB & GUTTER
6" CONCRETE
RESIDENTIAL DRIVEWAY
(TYPICAL)
(4" CONCRETE) (TYPICAL)
PROPERTY LINE
INGRESS/EGRESS ACCESS
3" ASPHALTIC CONCRETE
(TYPICAL)
RESIDENTIAL HOUSE
12" CONCRETE
(TYPICAL)
40'
Horizontal Scale: 1'' = 40'
Kelly C. Sills, L.L.C.
Legend
Earthen Material
Soil Cement Treated Base
Concrete
Germany Oaks, Phase 2
Section View B-B'
(Continued)
Ascension Parish, Louisiana
Asphaltic Concrete
Natural Ground elevations in existing jurisdictional wetlands are approximately 6" lower than
non-wetland ground elevations.
07-2017-DOA
02-22-2017
11
C'
C
20
TOP BANK
(ELEV: 17.0')
TOP BANK
(ELEV: 17.0')
WING WALL
(SLOPE=5:1)
WING WALL
(SLOPE=5:1)
ELEV:15.4'
SECONDARY WEIR
(80' CREST LENGTH)
15
15
Elevation, N.G.V.D.
Elevation, N.G.V.D.
20
DETENTION POND OUTFALL PIPES
DETENTION POND OUT FALL PIPES
10
10
Section C-C'
Horizontal Scale: 1" = 15'
Vertical Scale: 1" = 3'
15'
Notes
1.
The proposed layout was provided by Quality Engineering & Surveying, L.L.C.
2.
Jurisdictional Wetlands and Other Waters Of The U.S. obtained from U.S. Army CORPS of
Engineers Preliminary Jurisdictional Determination Account Number MVN-2016-00284-SK.
3.
According to F.E.M.A. F.I.R.M. Community Panel No. 22005C0040 E Dated 8-16-07, this
property falls in Flood Zone X (Other Areas; Areas Determined to be outside 0.2% annual
chance flood plain). Nearest Base Flood Elevation = 17.0' N.G.V.D.
4.
Non-wetland natural ground elevations average 20'-0" N.G.V.D. Elevation data was obtained
from topographic data provided by Quality Engineering & Surveying, L.L.C. Drainage Impact
Study.
5.
0
15'
Horizontal Scale: 1'' = 15'
Kelly C. Sills, L.L.C.
Legend
Concrete
Germany Oaks, Phase 2
Section View C-C'
Ascension Parish, Louisiana
Natural Ground elevations in existing jurisdictional wetlands are approximately 6" lower than
non-wetland ground elevations.
07-2017-DOA
02-22-2017
12