You can copy from here when filling out the rest of the page.
Miami-Dade County. Lennar Homes, LLC. Miami, FL. PROJECT PURPOSE: Basic: The basic project purpose is to construct residential housing. Overall: The overall project purpose is to construct residential housing in southwest Miami-Dade County.
TO WHOM IT MAY CONCERN: The Jacksonville District of the U.S. Army Corps of Engineers (Corps) has received an application for a Department of the Army permit pursuant to Section 404 of the Clean Water Act (33 U.S.C. §1344) as described below:
APPLICANT: Lennar Homes, LLC
730 NW 107th Ave., Suite 300
Miami, FL 33172
WATERWAY AND LOCATION: The project would affect waters of the United States associated with the Bird Drive Wetlands Basin. The project site is located between Southwest 44th Street and Southwest 45th Street and west of Southwest 157 Ave, to east of Southwest 160 Court, in Section 20, Township 54 South, Range 39 East, unincorporated Miami-Dade County, Florida (Folio #s 30-4920-001-0170, 30-4920-001-0180, 30-4920-001-0181, and 30-4920-001-0190).
Directions to the site are as follows: From Miami International Airport, proceed west on FL-836. From FL-836W, exit FL-825/NW 137 Ave. Take US-41 and SW 157 Ave to SW 44 Terrace. The proposed project site is located between Southwest 44th Street and Southwest 45th Street and west of Southwest 157 Ave, to east of Southwest 160 Court.
APPROXIMATE CENTRAL COORDINATES:
Latitude: 25.723275°
Longitude: -80.451233°
PROJECT PURPOSE:
Basic: The basic project purpose is to construct residential housing.
Overall: The overall project purpose is to construct residential housing in southwest Miami-Dade County.
EXISTING CONDITIONS: The wetland system consists of a freshwater system. The onsite vegetation consists of an herbaceous wetland composed of sawgrass-muhly grass with a saltbush/exotic dominated fringe in the Bird Drive Wetlands Basin. The existing area surrounding the project area consists of residential development on all four sides.
PROPOSED WORK: The applicant seeks authorization to construct a single-family residential development with associated infrastructure which includes roadways, landscaping and a stormwater management system which includes an on-site lake component by placing 171,176 cubic yards of fill in 22.33 acres of wetlands.
AVOIDANCE AND MINIMIZATION INFORMATION – The applicant has provided the following information in support of efforts to avoid and/or minimize impacts to the aquatic environment:
The applicant has stated, “Avoidance and minimization of impacts is considered to the extent practicable. Due to the development type proposed and municipal requirements, the proposed project needs to impact 22.33 acres of wetlands previously altered by farming activities.”
COMPENSATORY MITIGATION – The applicant has offered the following compensatory mitigation plan to offset unavoidable functional loss to the aquatic environment:
The applicant has stated, “Compensation for the unavoidable wetland impacts will occur as credits purchased from Everglades National Park Hole-in-the-Donut Mitigation Bank or Florida Power & Light Everglades Mitigation Bank.”
CULTURAL RESOURCES:
The Corps is not aware of any known historic properties within the permit area. By copy of this public notice, the Corps is providing information for review. Our final determination relative to historic resource impacts is subject to review by and coordination with the State Historic Preservation Officer and those federally recognized tribes with concerns in Florida and the Permit Area.
ENDANGERED SPECIES:
The Corps has determined the proposed project is “May affect but is not likely to adversely affect” the wood stork (Mycteria americana). Based on the Effect Determination Key for the Wood Stork in South Florida (dated May 18, 2010), the Corps determination sequence was A>B>C>D>E=MANLAA.
The Corps has determined the proposed project “May affect but is not likely to adversely affect” (MANLAA) the Eastern indigo snake (Drymarchon corais couperi). Based on the Eastern Indigo Snake Effect Determination Key (dated January 25, 2010; August 13, 2013 Addendum), the Corps determination sequence resulted in A>B>C>D>E= MANLAA.
Additionally, the Corps has determined that the project “may affect, but is not likely to adversely affect” the Florida Bonneted Bat (Eumops floridanus). Based on the 2013 FBB Effect Determination Guidelines, the Corps determination sequence resulted in 2>D = MANLAA. The Corps will request concurrence with this determination from the Fish and Wildlife Service pursuant to Section 7 of the Endangered Species Act by separate letter.
The Corps has determined that the proposed project will have “no effect” on the Everglades Snail Kite (Rostrahmus sociabilis plumbeus) because the project area provides no suitable habitat for the species.
The Corps has determined the proposal would have no effect on any other listed threatened or endangered species or designated critical habitat.
ESSENTIAL FISH HABITAT (EFH): This notice initiates consultation with the National Marine Fisheries Service on EFH as required by the Magnuson-Stevens Fishery Conservation and Management Act 1996. Our initial determination is that the proposed action would have no substantial adverse impact on EFH or Federally managed fisheries in the snapper-grouper complex. Our final determination relative to project impacts and the need for mitigation measures is subject to review by and coordination with the National Marine Fisheries Service.
NOTE: This public notice is being issued based on information furnished by the applicant. This information has not been verified or evaluated to ensure compliance with laws and regulation governing the regulatory program. The jurisdictional line has not been verified by Corps personnel.
AUTHORIZATION FROM OTHER AGENCIES: Water Quality Certification may be required from the Florida Department of Environmental Protection and/or one of the state Water Management Districts.
COMMENTS regarding the potential authorization of the work proposed should be submitted in writing to the attention of the District Engineer through the Miami Permits Section, 9900 SW 107th Avenue, Suite 203, Miami, FL 33176 within 21 days from the date of this notice.
The decision whether to issue or deny this permit application will be based on the information received from this public notice and the evaluation of the probable impact to the associated wetlands. This is based on an analysis of the applicant's avoidance and minimization efforts for the project, as well as the compensatory mitigation proposed.
QUESTIONS concerning this application should be directed to the project manager, Megan Clouser, in writing at the Miami Permits Section, 9900 SW 107th Avenue, Suite 203, Miami, FL 33176; by electronic mail at Megan.L.Clouser@usace.army.mil; by facsimile transmission at (305)526-7184; or, by telephone at (305)526-7182.
IMPACT ON NATURAL RESOURCES: Coordination with U.S. Fish and Wildlife Service, Environmental Protection Agency (EPA), the National Marine Fisheries Services, and other Federal, State, and local agencies, environmental groups, and concerned citizens generally yields pertinent environmental information that is instrumental in determining the impact the proposed action will have on the natural resources of the area.
EVALUATION: The decision whether to issue a permit will be based on an evaluation of the probable impact including cumulative impacts of the proposed activity on the public interest. That decision will reflect the national concern for both protection and utilization of important resources. The benefits, which reasonably may be expected to accrue from the proposal, must be balanced against its reasonably foreseeable detriments. All factors which may be relevant to the proposal will be considered including cumulative impacts thereof; among these are conservation, economics, esthetics, general environmental concerns, wetlands, historical properties, fish and wildlife values, flood hazards, floodplain values, land use, navigation, shoreline erosion and accretion, recreation, water supply and conservation, water quality, energy needs, safety, food, and fiber production, mineral needs, considerations of property ownership, and in general, the needs and welfare of the people. Evaluation of the impact of the activity on the public interest will also include application of the guidelines promulgated by the Administrator, EPA, under authority of Section 404(b) of the Clean Water Act or the criteria established under authority of Section 102(a) of the Marine Protection Research and Sanctuaries Act of 1972. A permit will be granted unless its issuance is found to be contrary to the public interest.
The US Army Corps of Engineers (Corps) is soliciting comments from the public; Federal, State, and local agencies and officials; Indian Tribes; and other Interested parties in order to consider and evaluate the impacts of this proposed activity. Any comments received will be considered by the Corps to determine whether to issue, modify, condition, or deny a permit for this proposal. To make this determination, comments are used to assess impacts to endangered species, historic properties, water quality, general environmental effects, and the other public interest factors listed above. Comments are also used to determine the need for a public hearing and to determine the overall public interest of the proposed activity.
COASTAL ZONE MANAGEMENT CONSISTENCY: In Florida, the State approval constitutes compliance with the approved Coastal Zone Management Plan. In Puerto Rico, a Coastal Zone Management Consistency Concurrence is required from the Puerto Rico Planning Board. In the Virgin Islands, the Department of Planning and Natural Resources permit constitutes compliance with the Coastal Zone Management Plan.
REQUEST FOR PUBLIC HEARING: Any person may request a public hearing. The request must be submitted in writing to the District Engineer within the designated comment period of the notice and must state the specific reasons for requesting the public hearing.
PROJECT NUMBER
1604-29
SHEET NUMBER
CS-1
THE MEADOWS
MIAMI-DADE COUNTY, FLORIDA
LENNAR HOMES
(T-x)
INDEX OF PLANS
GENERAL NOTES:
1. THIS PROPERTY IS LOCATED WITHIN FEMA FLOOD ZONE AH WHICH HAS A
BASE FLOOD ELEVATION OF +9.00 NGVD.
SHEET NO.
SHEET DESCRIPTION
2. THE MIAMI-DADE COUNTY FLOOD CRITERIA ELEVATION
FOR THIS PROPERTY
IS +8.60 NGVD.
CS-1
COVER SHEET
PD-1
PAVING AND DRAINAGE PLAN
PD-2
PAVING AND DRAINAGE PLAN
PD-3
PAVING AND DRAINAGE PLAN
PD-4
PAVING AND DRAINAGE PLAN
PD-5
PAVING AND DRAINAGE DETAILS
PD-6
PAVING AND DRAINAGE DETAILS
PD-7
PAVING AND DRAINAGE DETAILS
PD-8
PAVING AND DRAINAGE DETAILS
3. THE AVERAGE MAY GROUND WATER LEVEL IS +4.00 NGVD PER MAP W.C. 2.4
4. THE AVERAGE OCTOBER GROUND WATER LEVEL IS +5.50 NGVD PER MAP W.C. 2.2
5. THE MINIMUM GARAGE ELEVATION ON THIS PROJECT NEEDS TO BE SET AT
W.43RD STREET
S.
+10.00 NGVD.
W .159TH PLAC E
S.
E
W .159TH AV EN U
S.
6. ELEVATIONS ARE BASED ON: NATIONAL GEODETIC VERTICAL DATUM OF 1929.
MIAMI-DADE BENCH MARK USED: P-4065
ELEVATION: 9.83' (N.G.V.D. 1929)
BENCH MARK LOCATION: S.W. 47TH STREET -- 45' SOUTH OF CL
S.W. 157TH AVENUE -- ON CL
BENCH MARK IS A PK NAIL AND BRASS WASHER IN CONCRETE
MEDIAN.
FLOOD ZONE:"AH"
BASED FLOOD ELEVATION:9.00' AS PER
COMMUNITY NUMBER: 120635
FEMA MAP NUMBER: 12086C0427L
EFFECTIVE DATE: SEPTEMBER 11, 2009
REVISED DATE: SEPTEMBER 11, 2009
W .158TH CO U RT
S.
E
W .159TH AV EN U
S.
W .159TH CO U RT
S.
W .159TH PLAC E
S.
E
W.45TH TERRAC
S.
E
W .157TH AV EN U
S.
E
W .162N D AV EN U
S.
E
W.44TH TERRAC
S.
2/
23/
2017
PROJECT LOCATION
W.44TH STREET
S.
LOCATION MAP
SCALE: 1" = 300'
SECTION 20 / TOWNSHIP 54 S / RANGE 39 E
LEGAL DESCRIPTION:
PARCEL ONE:
THE SOUTH 1/2 OF TRACT 17, OF MIAMI EVERGLADES LAND COMPANY
SUBDIVISION SECTION 20, ACCORDING TO PLAT THEREOF, AS RECORDED
IN PLAT BOOK 2, PAGE 3 OF THE PUBLIC RECORDS OF MIAMI-DADE
PAVING AND DRAINAGE PLANS
COUNTY, FLORIDA.
PARCEL TWO:
TRACT 19, AND THE NORTH 1/2 TRACT 18, OF MIAMI EVERGLADES LAND
N
A
EAST, ACCORDING TO PLAT THEREOF, AS RECORDED IN PLAT BOOK 2,
I
L
PAGE 3 OF THE PUBLIC RECORDS OF MIAMI-DADE COUNTY, FLORIDA.
PARCEL THREE:
SOUTH 1/2 OF TRACT 18, SECTION 20, TOWNSHIP 54 SOUTH, RANGE 39
E
O
COMPANY SUBDIVISION IN SECTION 20, TOWNSHIP 54 SOUTH, RANGE 39
O QUEV
NI
E
O
D
T
CEN S
No 59471
Approved by: ANTONIO QUEVEDO
Registered Engineer Number: 59471
State of Florida
s
r
o
y
e
v
r
Su
s·
r
e
n
n
a
Pl
s·
r
e
e
n
i
g
En
ENGINEER'S CERTIFICATION
E
A
N
Date: 2/23/2017
F
LO
E Seal
R ID
I
S
G
SI
ONAL EN
F
NOTE: ALL PARCELS ARE CONTIGUOUS WITH NO GAPS OR GORES.
STATE OF
O
FLORIDA.
PR
BOOK 2, PAGE 3 OF THE PUBLIC RECORDS OF MIAMI-DADE COUNTY,
ER
EAST, OF MIAMI EVERGLADES LAND COMPANY SUBDIVISION, IN PLAT
NC.
HSQ GROUP,I
e4
t
i
Su
,
e
v
i
dDr
r
3
7
1
t
s
we
h
t
r
1No
5
9
5
1
2
6
3
.
4
3
5
.
6
8
7
5·
1
0
3
a3
d
i
r
o
l
F
,
mi
a
Mi
C26258 · LB7924
THESE PLANS WERE PREPARED UNDER MY DIRECTION AND TO THE BEST OF
MY KNOWLEDGE AND BELIEF COMPLY WITH THE INTENT OF THE MANUAL OF
UNIFORM MINIMUM STANDARDS FOR DESIGN, CONSTRUCTION AND
MAINTENANCE FOR STREETS AND HIGHWAYS AS ADOPTED BY THE STATE
OF FLORIDA LEGISLATURE, CHAPTER 72-328 F.S.
Z:
\
HSQ Dade\
Ci
vi
lPr
oj
ect
s\
2017\
170207 The M eadows\
Dr
awi
ngs\
Const
r
uct
i
on Pl
ans\
170207PDC001.
dgn
W.47TH STREET
S.
PARK LAKES SECTION ONE
(P.B. 155, PG. 89)
LEGEND
DRAINAGE INLET SCHEDULE
.5
8
.4
8
EXISTING ASPHALT TO REMAIN
A-1
BLOCK 1
PROPOSED ASPHALT, LIMEROCK &
SUBGRADE (SEE SHEET PD-5 FOR DETAILS)
LOT 8
LOT 7
LOT 6
LOT 5
LOT 4
F.F. EL. = +10.5010.50 NGVD
F.F. EL. = +10.50 NGVD
F.F. EL. = +10.50 NGVD
F.F. EL. = +10.50 NGVD
F.F. EL. = +10.50 NGVD
F.F. EL. = +10.50 NGVD
F.F. EL. = +10.50 NGVD
.3
5
LOT 9
LOT 2
LOT 1
F.F. EL. = +10.50 NGVD
F.F. EL. = +10.50 NGVD
F.F. EL. = +10.50 NGVD
EXISTING ASPHALT TO BE MILLED &
RESURFACED
(SEE SHEET PD-5 FOR DETAILS)
A-2
.1
5
.0
5
.8
4
.9
4
SCALE: 1"=30'
PROP. 5'-18" H.D.P.E.
& 25'-18" P.H.D.P.E. W/
4' WIDE TRENCH
25'
50'
R
4
0
'
25'
PROP. VALLEY GUTTER
PROP. HANDICAP RAMP
W/ TACTILE WARNING
PER FDOT INDEX 304
PROP. 116'-24" H.D.P.E.
LOT 19
70
9.
64
9.
PROP. VALLEY GUTTER
LOT 4
PROP. 24' WHITE STOP BAR
W/ 25'-6" DBL. YELLOW
E.
D.
'
0
1
.
OP
R
P
LOT 2
LOT 1
F.F. EL. = +10.50 NGVD
F.F. EL. = +10.50 NGVD
PROP. 5' CONC. S/W
F.F. EL. = +10.50 NGVD
LOT 15
LOT 16
F.F. EL. = +10.50 NGVD
F.F. EL. = +10.50 NGVD
F.F. EL. = +10.50 NGVD
PROP. 10'-18" H.D.P.E.
& 106'-18" P.H.D.P.E. W/
4' WIDE TRENCH
.0
5
.2
5
R/W
25'
8.60
20'
50'
9.65
8.80
8.60
25'
.1
5
R
A
8.
81
8.
88
.0
5
PROP. 98'-18" H.D.P.E.
B-5
8.60
8.80
PROP. VALLEY GUTTER
PROP. 122'-24" H.D.P.E.
R
98
8.
36
'
8.9
6
B-4
PROP. HANDICAP RAMP
W/ TACTILE WARNING
PER FDOT INDEX 304
.4
5
PROP. 22'-24" H.D.P.E.
EXIST. SAN. SEWER M.H.
PER MD-WASD ES-7639-2
R.E.9.32
I.E. 1.17 W
1.04 E
'
36
.5
8
.3
5
.5
7
STOP
.3
5
R1-1 "STOP SIGN"
(30" X 30")
R/W
B-6
B-3
PROP. 24' WHITE STOP BAR
W/ 25'-6" DBL. YELLOW
A-8
R1-1 "STOP SIGN"
(30" X 30")
B-2
PARK LAKES BY THE
MEADOWS PHASE FOUR
(P.B. 157, PG. 32)
4'
PROP. 35'-24" H.D.P.E.
9.45
PROP. HANDICAP RAMP
W/ TACTILE WARNING
PER FDOT INDEX 304
8.
95
PROP. 5'-18" H.D.P.E.
& 25'-18" P.H.D.P.E. W/
4' WIDE TRENCH
9.45
9.00
S
PROP. 5'-18" H.D.P.E.
& 25'-18" P.H.D.P.E. W/
4' WIDE TRENCH
S TO P
9.
13
A-6
.3
8
PROP. VALLEY GUTTER
WV
PROP. VALLEY GUTTER
.3
5
.1
5
.4
5
S
A-4
PROP. 124'-24" H.D.P.E.
PROP. 24' WHITE STOP BAR
W/ 25'-6" DBL. YELLOW
LOT 34
LOT 33
F.F. EL. = +10.50 NGVD
F.F. EL. = +10.50 NGVD
F.F. EL. = +10.50 NGVD
LOT 31
F.F. EL. = +10.50 NGVD
F.F. EL. = +10.50 NGVD
B-6
EXIST. DRAINAGE INLET
LOT 36
F.F. EL. = +10.50 NGVD
BLOCK 3
LOT 37
R/W
.3
8
F.F. EL. = +10.50 NGVD
.8
6
56
8.
F.F. EL. = +10.50 NGVD
PROP. 23'-24" R.C.P.
PROP. EDGE OF WATER
.3
5
LOT 38
A-9
B
B-7
TYPE "P" BOX (48" ROUND W/ TOP SLAB)
PER MDPWD. DETAIL SD 2.6
W/ U.S.F. 5105-6148 FRAME & HINGED GRATE
R.E.8.60
I.E. 4.50 NW (PRB)
4.50 SE (PRB)
4.50 NE
TYPE "P" BOX (48" ROUND W/ TOP SLAB)
PER MDPWD. DETAIL SD 2.6
W/ U.S.F. 5105-6148 FRAME & HINGED GRATE
R.E.8.60
I.E. 4.50 SW
4.50 NE
TYPE "P" BOX (48" ROUND W/ TOP SLAB)
PER MDPWD. DETAIL SD 2.6
W/ CONC. APRON & U.S.F. 6606 GRATE
R.E.9.50
I.E. 4.50 SW
4.50 SE
TYPE "P" BOX (48" ROUND W/ TOP SLAB)
PER MDPWD. DETAIL SD 2.6
W/ U.S.F. 5105-6148 FRAME & HINGED GRATE
R.E.8.60
I.E. 4.50 E (PRB)
4.50 W (PRB)
4.50 NE
TYPE "P" BOX (48" ROUND W/ TOP SLAB)
PER MDPWD. DETAIL SD 2.6
W/ CONC. APRON & U.S.F. 6606 GRATE
R.E.9.50
I.E. 4.50 SE
4.50 NW
4.50 NE
TYPE "P" BOX (48" ROUND W/ TOP SLAB)
PER MDPWD. DETAIL SD 2.6
W/ U.S.F. 5105-6148 FRAME & HINGED GRATE
R.E.8.60
I.E. 4.50 SW
4.50 NW (PRB)
4.50 SE (PRB)
4.50 NE
TYPE "P" BOX (48" ROUND W/ TOP SLAB)
PER MDPWD. DETAIL SD 2.6
W/ U.S.F. 5105-6148 FRAME & HINGED GRATE
R.E.8.60
I.E. 4.50 SW
4.00 NE
MATCHLINE - SEE SHEET PD-2
R/W
REVISION
Designed by:
Drawn by:
Checked by:
AQ
RW
AQ
Date:
Date:
Date:
2/17
.3
5
.4
5
.3
5
.4
5
F.F. EL. = +10.50 NGVD
.8
6
44
8.
62
8.
PROP. VALLEY GUTTER
11'-0" CONCRETE HEADWALL
PER FDOT INDEX 250
CAP OF HEADWALL EL. 6.08
I.E. 2.83
8.
75
PROP. TOP OF BANK
8.
81
77
8.
LOT 1
B
8.8
9
PROP. HANDICAP RAMP
W/ TACTILE WARNING
PER FDOT INDEX 304
MATCH EXISTING
PAVEMENT ELEVATIONS
LOT 35
LOT 32
C
88
8.
57
8.
3
6
'
.4
8
.4
5
R
8.
56
8.60
8.
74
.8
7
96
8.
4'
8.8
6
MATCH EXISTING
PAVEMENT ELEVATIONS
B-7
Approved by: ANTONIO QUEVEDO
A-10
NC.
HSQ GROUP,I
Engineers · Planners · Surveyors
2/17
2/17
Date: 2/23/2017
C
9
.1
6
9
.0
1
BY
0'
R 25
PROP. VALLEY GUTTER
8.60
EXIST. SAN. SEWER M.H.
PER MD-WASD ES-6570-4
R.E.9.04
I.E. (-) 5.19 S
(-) 5.61 E
(-) 5.59 W
12" WHITE CROSSWALK PER
FDOT INDEX 17346, 5' WIDE
'
36
F.F. EL. = +10.50 NGVD
12" WHITE CROSSWALK PER
FDOT INDEX 17346, 5' WIDE
BARIMA ESTATES
(P.B. 139, PG. 13)
DATE
A-7
PROP. 5' CONC. S/W
PROP. 114'-24" H.D.P.E.
EXIST. 12" D.I.P. WATER MAIN
PER M-DWASD AS-BUILT
E-2805-8
NO.
R
LOT 9
PROP. 5' CONC. S/W
EXIST. 8" D.I.P. WATER MAIN
PER M-DWASD AS-BUILT
E-10839-2
9.
02
E.
D.
'
0
1
.
OP
PR
PROP. 5'-18" H.D.P.E.
& 25'-18" P.H.D.P.E. W/
4' WIDE TRENCH
B-1
PROP. 10'-18" H.D.P.E.
& 104'-18" P.H.D.P.E. W/
4' WIDE TRENCH
.5
4
.4
6
38
8.
14
8.
2
.0
8
S.
W .45th TERRACE
LOT 10
A
S
0
.9
7
8
.1
2
PROP. HANDICAP RAMP
W/ TACTILE WARNING
PER FDOT INDEX 304
F.F. EL. = +10.50 NGVD
PROP. 78'-18" H.D.P.E.
B-4
8
.8
2
R/W
.3
8
F.F. EL. = +10.50 NGVD
PROPOSED DRAINAGE CONTROL STRUCTURE
(SEE DETAILS)
R.E.9.00
I.E. 4.00 W
3.00 SE
8.
76
LOT 17
LOT 11
F.F. EL. = +10.50 NGVD
8
.7
5
WV
R/W
PROP. 114'-24" H.D.P.E.
.0
5
PROP. 90'-24" H.D.P.E.
EXIST. 8" D.I.P. WATER MAIN
PER M-DWASD AS-BUILT
E-2805-8
S.W. 159th
COURT
9.
03
F.F. EL. = +10.50 NGVD
B-5
A-9
A-10
8.
89
.7
7
LOT 12
EXIST. SAN. SEWER M.H.
PER MD-WASD ES-6570-4
R.E.8.38
I.E. (-) 5.03 E
(-) 4.77 W
R/W
.8
4
F.F. EL. = +10.50 NGVD
E.
.
0'D
P.1
F.F. EL. = +10.50 NGVD
PROP. 5'-18" H.D.P.E.
& 25'-18" P.H.D.P.E. W/
4' WIDE TRENCH
B-3
O
PR
39
8.
67
8.
LOT 8
S.
W .44th STREET
.5
8
LOT 14
8.
63
.2
5
.9
8
BLOCK 2
EXIST. DRAINAGE INLET
Registered Engineer Number
State of Florida
59471
5951 Northwest 173rd Drive, Suite 4
Miami, Florida 33015 · 786.534.3621
C26258 · LB7924
2/
23/
2017
8.60
F.F. EL. = +10.50 NGVD
LOT 13
R/W
TYPE "P" BOX (48" ROUND W/ TOP SLAB)
PER MDPWD. DETAIL SD 2.6
W/ U.S.F. 5105-6148 FRAME & HINGED GRATE
R.E.8.60
I.E. 4.50 NW
4.00 E
PROJECT NUMBER
THE MEADOWS
1702-07
SHEET NUMBER
PAVING AND DRAINAGE PLAN
PD-1
Z:
\
HSQ Dade\
Ci
vi
lPr
oj
ect
s\
2017\
170207 The M eadows\
Dr
awi
ngs\
Const
r
uct
i
on Pl
ans\
170207PDP001.
dgn
A-5
LOT 18
8.
77
A-3
LOT 6
R/W
A-8
R/W
LOT 7
8
.9
4
TYPE "P" BOX (48" ROUND W/ TOP SLAB)
PER MDPWD. DETAIL SD 2.6
W/ U.S.F. 5105-6148 FRAME & HINGED GRATE
R.E.8.60
I.E. 4.50 N,SE,W
F.F. EL. = +10.50 NGVD
F.F. EL. = +10.50 NGVD
SAWCUT AND MATCH EXISTING
PAVEMENT ELEVATIONS
A-7
R/W
EXIST. 12" C-900 PVC SAN. SEWER
PER M-DWASD AS-BUILT
ES-7639-2
8.
89
18
9.
97
8.
LOT 3
F.F. EL. = +10.50 NGVD
LOT 5
B
BARIMA ESTATES
(P.B. 139, PG. 13)
8.
82
19
9.
40
'
PROP. HANDICAP RAMP
W/ TACTILE WARNING
PER FDOT INDEX 304
EXIST. 10" D.I.P. SAN. SEWER
PER M-DWASD AS-BUILT
ES-6570-4
4' DIA. DRAINAGE MANHOLE
W/ RING AND COVER PER MDPWD SD 4.4
R.E.9.00
I.E. 4.50 W (PRB)
4.50 E,S
PROP. 113'-24" H.D.P.E.
B
EXIST. DRAINAGE INLET
R.E.7.86
8.
94
9.
04
.8
8
71
9.
MATCH EXISTING
PAVEMENT ELEVATIONS
TYPE "P" BOX (48" ROUND W/ TOP SLAB)
PER MDPWD. DETAIL SD 2.6
W/ U.S.F. 5105-6148 FRAME & HINGED GRATE
R.E.8.60
I.E. 4.50 E (PRB)
H
EXIST. FIRE HYDRANT
PER M-DWASD AS-BUILT
E-10839-2
F.F. EL. = +10.50 NGVD
F.F. EL. = +10.50 NGVD
PARK LAKES BY THE
MEADOWS PHASE SIX
(P.B. 158, PG. 58)
Y D
W
V
PROP. 10' D.E.
SAWCUT AND MATCH EXISTING
PAVEMENT ELEVATIONS
MATCH EXISTING
PAVEMENT ELEVATIONS
R/W
.3
9
S
W
ST.50'R/
EXI
A
8.80
9
.5
4
4
.3
9
R/W
A-5
A-6
3
.9
8
P
STO
PROP. 22'-24" H.D.P.E.
B-2
12" WHITE CROSSWALK PER
FDOT INDEX 17346, 5' WIDE
R
5
.7
8
R1-1 "STOP SIGN"
(30" X 30")
TYPE "P" BOX (48" ROUND W/ TOP SLAB)
PER MDPWD. DETAIL SD 2.6
W/ U.S.F. 5105-6148 FRAME & HINGED GRATE
R.E.8.60
I.E. 4.50 W
02
9.
WV
8.60
8.60
7
.8
9
PROP. 5' CONC. S/W
STOP
R1-1 "STOP SIGN"
(30" X 30")
'
4
6
.5
9
S.W. 159th
PLACE
1
.8
9
WV
S.W. 159th
PATH
SAWCUT AND MATCH EXISTING
PAVEMENT ELEVATIONS
A-2
B-1
4
.8
9
R/W
9
.3
9
8.60
A-4
1
.0
9
9.40
20'
EXIST. SAN. SEWER M.H.
PER MD-WASD ES-6570-4
R.E.9.88
I.E. (-) 2.71 E
(-) 1.12 S
.5
5
PROP. 5'-18" H.D.P.E.
& 25'-18" P.H.D.P.E. W/
4' WIDE TRENCH
.2
9
N.T.S.
9
.2
5
4'
8.80
PD-4
PROP. HANDICAP RAMP
W/ TACTILE WARNING
PER FDOT INDEX 304
PROP. 22'-24" H.D.P.E.
S
.4
5
9.60
.8
4
0'
R 50
.0
5
.2
5
PROP. 5'-18" H.D.P.E.
& 25'-18" P.H.D.P.E. W/
4' WIDE TRENCH
6
.0
9
8.60
.4
5
.0
5
PD-3
KEY MAP
PROP. 24' WHITE STOP BAR
W/ 25'-6" DBL. YELLOW
PROP. VALLEY GUTTER
9.40
6
.0
9
.0
9
R/W
PD-2
EXIST. SAN. SEWER M.H.
PER MD-WASD ES-7639-2
R.E.9.49
I.E.
WV
A-1
TYPE "P" BOX (48" ROUND W/ TOP SLAB)
PER MDPWD. DETAIL SD 2.6
W/ CONC. APRON & U.S.F. 6606 GRATE
R.E.9.50
I.E. 4.50 E,W
.5
8
PROP. 5'-18" H.D.P.E.
& 25'-18" P.H.D.P.E. W/
4' WIDE TRENCH
PROP. 5' CONC. S/W
A-3
6
.7
8
A
PROP. HANDICAP RAMP
W/ TACTILE WARNING
PER FDOT INDEX 304
6
.0
9
PD-1
EXIST. 8" D.I.P. WATER MAIN
PER M-DWASD AS-BUILT
E-10839-2
8
.8
8
FEET
EXIST. 12" D.I.P. WATER MAIN
PER M-DWASD AS-BUILT
E-11034-2
TYPE "P" BOX (48" ROUND W/ TOP SLAB)
PER MDPWD. DETAIL SD 2.6
W/ U.S.F. 5105-6148 FRAME & HINGED GRATE
R.E.8.60
I.E. 4.50 E,W
.5
5
.9
8
.2
5
60
LOT 3
.1
5
30
0
LOT 10
TYPE "P" BOX (48" ROUND W/ TOP SLAB)
PER MDPWD. DETAIL SD 2.6
W/ U.S.F. 5105-6148 FRAME & HINGED GRATE
R.E.8.60
I.E. 4.50 N (PRB)
4.50 S (PRB)
4.50 E
8.
75
8.
81
.3
8
50' R/W
25'
25'
LOT 30
F.F. EL. = +10.50 NGVD
MATCHLINE - SEE SHEET PD-1
EXIST. 8" D.I.P. WATER MAIN
PER M-DWASD AS-BUILT
E-10839-2
MATCH EXISTING PAVEMENT
ELEVATIONS
8.9
8
50' R/W
PROP. 124'-24" H.D.P.E.
25'
E.
PROP.10'D.
8.
93
9.
00
FEET
B-8
SCALE: 1"=30'
F.F. EL. = +10.50 NGVD
B-9
LOT 28
F.F. EL. = +10.50 NGVD
Y D
25'
25'
PD-2
PD-3
D-3
8.60
.1
5
.0
5
.2
5
PROP. 14'-24" R.C.P.
D-2
.2
5
.9
4
.4
7
20
8.
0
.4
8
PROP. 128'-18" H.D.P.E.
F.F. EL. = +10.50 NGVD
E-2
.5
7
0
.3
8
4.98 ACRES @
MEAN-LOW WATER LEVEL
KEY MAP
3
.7
8
LOT 6
F.F. EL. = +10.50 NGVD
0
.9
8
4
.4
8
PROPOSED LAKE
PROP. 5'-18" H.D.P.E.
& 25'-18" P.H.D.P.E. W/
4' WIDE TRENCH
.4
8
PROP. 5'-18" H.D.P.E.
& 25'-18" P.H.D.P.E. W/
4' WIDE TRENCH
4
.5
8
8
.3
8
1
.4
8
PD-4
LOT 25
B
2/
23/
2017
E.
PROP.10'D.
PD-1
6
.8
8
1
.0
9
.4
8
PROP. TOP OF BANK
EXISTING ASPHALT TO BE MILLED &
RESURFACED
(SEE SHEET PD-5 FOR DETAILS)
4
.8
8
.0
7
7
.4
8
D-1
F.F. EL. = +10.50 NGVD
S.
W .44th STREET
83
8.
LOT 26
F.F. EL. = +10.50 NGVD
E.
PROP.10'D.
25'
W
50'R/
80
8.
1
.6
8
PROP. EDGE OF WATER
PROPOSED ASPHALT, LIMEROCK &
SUBGRADE (SEE SHEET PD-5 FOR DETAILS)
9
.0
9
3
.5
8
E-3
LOT 5
EXIST. DRAINAGE INLET
R.E.7.76
0
.2
9
BLOCK 3
11'-0" CONCRETE HEADWALL
PER FDOT INDEX 250
CAP OF HEADWALL EL. 6.08
I.E. 2.83
LEGEND
EXISTING ASPHALT TO REMAIN
.8
8
.1
7
4
.6
8
PROPOSED DRAINAGE CONTROL STRUCTURE
(SEE DETAILS)
R.E.9.00
I.E. 4.00 N
3.00 S
EXIST. SAN. SEWER M.H.
PER MD-WASD ES-7639-2
R.E.9.39
I.E. 0.12 W
0.24 E
PROP. VALLEY GUTTER
EXIST. 10" D.I.P. SAN. SEWER
PER M-DWASD AS-BUILT
ES-6570-4
BARIMA ESTATES
(P.B. 139, PG. 13)
8.
96
LOT 27
F.F. EL. = +10.50 NGVD
3
.0
9
E-2
EXIST. DRAINAGE MANHOLE
R.E. 9.29
S
.2
5
11'-0" CONCRETE HEADWALL
PER FDOT INDEX 250
CAP OF HEADWALL EL. 6.08
I.E. 2.83
TYPE "P" BOX (48" ROUND W/ TOP SLAB)
PER MDPWD. DETAIL SD 2.6
W/ U.S.F. 5105-6148 FRAME & HINGED GRATE
R.E.8.60
I.E. 4.50 E (PRB)
4.50 W (PRB)
4.50 S
BLOCK 3
PROP. 5'-18" H.D.P.E.
& 25'-18" P.H.D.P.E. W/
4' WIDE TRENCH
9.
07
E-1
9
.1
2
PROPOSED DRAINAGE CONTROL STRUCTURE
(SEE DETAILS)
R.E.9.00
I.E. 4.00 S
3.00 N
.9
4
.8
4
.4
5
64
8.
C-3
8.
94
C-2
WV
S
.3
7
LOT 4
S.W. 159th
AVENUE
9
.1
9
WV
9
.0
7
25'
9.
40
PROP. 5' CONC. S/W
C
F.F. EL. = +10.50 NGVD
EXIST. SAN. SEWER M.H.
PER MD-WASD ES-6570-4
R.E.8.88
I.E. (-) 6.04 N
(-) 6.35 E
(-) 5.99 S
(-) 6.31 W
C
SAWCUT AND MATCH
EXISTING PAVEMENT
ELEVATIONS
T
C
C
11'-0" CONCRETE HEADWALL
PER FDOT INDEX 250
CAP OF HEADWALL EL. 6.08
I.E. 2.83
9
.4
9
WV
D-3
EXIST. 8" D.I.P. WATER MAIN
PER M-DWASD AS-BUILT
E-10842-2
3
.4
9
4
.6
8
3
.8
8
PROP. 5' CONC. S/W
TYPE "P" BOX (48" ROUND W/ TOP SLAB)
PER MDPWD. DETAIL SD 2.6
W/ U.S.F. 5105-6148 FRAME & HINGED GRATE
R.E.8.60
I.E. 4.50 E (PRB)
4.50 W (PRB)
4.50 N
.0
9
.2
7
2
.6
8
C-1
8
.8
9
WV
LOT 28
EXIST. 8" D.I.P. WATER MAIN
PER M-DWASD AS-BUILT
E-2805-8
13
9.
PROP. TOP OF BANK
PROPOSED DRAINAGE CONTROL STRUCTURE
(SEE DETAILS)
R.E.9.00
I.E. 4.00 S
3.00 N
F.F. EL. = +10.50 NGVD
SAWCUT AND MATCH EXISTING
PAVEMENT ELEVATIONS
S.W. 159th
AVENUE
D-2
8
S 9.5
4
.7
8
MATCH EXISTING PAVEMENT
ELEVATIONS
11'-0" CONCRETE HEADWALL
PER FDOT INDEX 250
CAP OF HEADWALL EL. 6.08
I.E. 2.83
.1
5
B-9
.9
4
PROP. VALLEY GUTTER
WV
EXIST. SAN. SEWER M.H.
PER MD-WASD ES-7639-2
R.E.9.65
I.E. 1.68 N
0.57 W
0.40 E
PROP. EDGE OF WATER
F.F. EL. = +10.50 NGVD
EXIST. FIRE HYDRANT
PER M-DWASD AS-BUILT
E-10839-2
H
.4
5
.3
5
.2
5
.4
5
.4
5
LOT 3
EXIST. 12" D.I.P. WATER MAIN
PER M-DWASD AS-BUILT
E-2805-8
D-1
TYPE "P" BOX (48" ROUND W/ TOP SLAB)
PER MDPWD. DETAIL SD 2.6
W/ U.S.F. 5105-6148 FRAME & HINGED GRATE
R.E.8.60
I.E. 4.50 E (PRB)
4.50 W (PRB)
4.50 N
9.2
4
.0
7
42
8.
PROP. 5'-18" H.D.P.E.
& 25'-18" P.H.D.P.E. W/
4' WIDE TRENCH
9.
34
B-8
PROPOSED DRAINAGE CONTROL STRUCTURE
(SEE DETAILS)
R.E.9.00
I.E. 4.00 SW
3.00 NE
.7
8
PROP. 14'-24" R.C.P.
C-2
.0
5
59
8.
PROP. 128'-18" H.D.P.E.
.4
5
DRAINAGE INLET SCHEDULE
C-3
8.60
BARIMA ESTATES
(P.B. 139, PG. 13)
60
LOT 2
W
50'R/
.3
7
24
8.
9
.4
8
C-1
30
0
.3
8
PROP. 16'-24" R.C.P.
PROP. 5'-18" H.D.P.E.
& 25'-18" P.H.D.P.E. W/
4' WIDE TRENCH
50
8.
17
8.
1
.5
8
EXIST. DRAINAGE INLET
R.E.7.72
.3
5
25'
N.T.S.
EXIST. DRAINAGE INLET
PARK LAKES BY THE
MEADOWS PHASE FIVE
(P.B. 157, PG. 23)
8.60
E-3
B
PROP. 128'-18" H.D.P.E.
E-1
87
8.
MATCH EXISTING PAVEMENT
ELEVATIONS
H
Y
WV
LOT 8
LOT 22
5
.1
9
.3
5
25'
25'
.3
5
50' R/W
0
.3
9
2
.4
9
.9
8
.3
5
.0
5
.1
5
50' R/W
F.F. EL. = +10.50 NGVD
.2
5
.3
5
F.F. EL. = +10.50 NGVD
25'
EXIST. FIRE HYDRANT
PER M-DWASD AS-BUILT
E-10842-2
MATCHLINE - SEE SHEET PD-3
NO.
DATE
BY
REVISION
Designed by:
Drawn by:
Checked by:
AQ
RW
AQ
Date:
Date:
Date:
2/17
Approved by: ANTONIO QUEVEDO
NC.
HSQ GROUP,I
Engineers · Planners · Surveyors
2/17
2/17
Date: 2/23/2017
Registered Engineer Number
State of Florida
59471
5951 Northwest 173rd Drive, Suite 4
Miami, Florida 33015 · 786.534.3621
C26258 · LB7924
PROJECT NUMBER
THE MEADOWS
1702-07
SHEET NUMBER
PAVING AND DRAINAGE PLAN
PD-2
Z:
\
HSQ Dade\
Ci
vi
lPr
oj
ect
s\
2017\
170207 The M eadows\
Dr
awi
ngs\
Const
r
uct
i
on Pl
ans\
170207PDP002.
dgn
3
.2
9
.7
8
VALENTI SUBDIVISION
(P.B. 158, PG. 83)
.0
5
.5
5
B
3
.0
9
8
.0
9
B
LOT 23
F.F. EL. = +10.50 NGVD
D
25'
4
.9
8
F.F. EL. = +10.50 NGVD
.4
5
W
50'R/
8
.8
8
3
.1
9
.4
8
.5
5
.6
4
EXIST. 8" D.I.P. WATER MAIN
PER M-DWASD AS-BUILT
E-10842-2
LOT 7
.6
7
2
.8
8
25'
PROP. 5'-18" H.D.P.E.
& 25'-18" P.H.D.P.E. W/
4' WIDE TRENCH
MATCH EXISTING PAVEMENT
ELEVATIONS
S 8.67
25'
EXIST. 12" C-900 PVC SAN. SEWER
PER M-DWASD AS-BUILT
ES-7639-2
F.F. EL. = +10.50 NGVD
WV
8
.5
6
EXIST. SAN. SEWER M.H.
PER MD-WASD ES-6570-4
R.E.8.83
I.E. (-) 9.12 E
(-) 9.30 S
(-) 9.26 W
EXIST. 8" D.I.P. FORCE MAIN
PER M-DWASD AS-BUILT
ES-6570-4
.1
5
S
8.
67
EXIST. SAN. SEWER M.H.
PER MD-WASD ES-6570-4
R.E.8.95
I.E. (-) 8.77 N
(-) 9.32 E
(-) 8.79 S
(-) 7.22 W
BARIMA ESTATES
(P.B. 139, PG. 13)
.2
5
4
.6
8
9
.2
0
8
.9
1
S.W. 158th
COURT
WV
.2
5
EXIST. 8" D.I.P. WATER MAIN
PER M-DWASD AS-BUILT
E-2805-8
.9
4
.8
7
7
.5
8
SAWCUT AND MATCH EXISTING
PAVEMENT ELEVATIONS
LOT 24
.9
4
8
.6
8
S.
W .45th TERRACE
PROP. 14'-24" R.C.P.
50' R/W
LOT 22
F.F. EL. = +10.50 NGVD
.5
5
.5
5
.9
7
PROPOSED LAKE
E.
PROP.10'D.
EXISTING ASPHALT TO REMAIN
PROPOSED ASPHALT, LIMEROCK &
SUBGRADE (SEE SHEET PD-5 FOR DETAILS)
EXISTING ASPHALT TO BE MILLED &
RESURFACED
(SEE SHEET PD-5 FOR DETAILS)
C
H-4
LEGEND
R/W
PROP. 128'-24" H.D.P.E.
1
.9
8
8
.9
8
E.
PROP.10'D.
H-3
F.F. EL. = +10.50 NGVD
5
.0
9
.2
8
.3
5
PROP. 20'-24" R.C.P.
PROP. 14'-24" R.C.P.
G-3
PROP. 5' CONC. S/W
R/W
PROP. VALLEY GUTTER
BLOCK 3
LOT 19
C
53
8.
.0
7
57
8.
PD-1
F.F. EL. = +10.50 NGVD
LOT 13
LOT 14
LOT 15
LOT 16
LOT 17
F.F. EL. = +10.50 NGVD
F.F. EL. = +10.50 NGVD
F.F. EL. = +10.50 NGVD
F.F. EL. = +10.50 NGVD
F.F. EL. = +10.50 NGVD
F.F. EL. = +10.50 NGVD
F.F. EL. = +10.50 NGVD
4
.7
8
8
.7
8
LOT 12
PD-2
.4
8
92
8.
LOT 11
3
.9
8
.2
5
PROP. 10'-18" H.D.P.E.
& 132'-18" P.H.D.P.E. W/
4' WIDE TRENCH
PD-3
S
67
8.
.4
7
S.
W .45th TERRACE
.5
5
.8
4
G-4
H-5
.2
5
.3
5
.4
7
11
8.
34
8.
7
.3
8
PROP. 5'-18" H.D.P.E.
& 25'-18" P.H.D.P.E. W/
4' WIDE TRENCH
SCALE: 1"=30'
VALENTI SUBDIVISION
(P.B. 158, PG. 83)
9
.0
9
1
.1
9
F.F. EL. = +10.50 NGVD
60
FEET
EXIST. 8" D.I.P. WATER MAIN
PER M-DWASD AS-BUILT
E-10842-2
7
.1
9
.4
8
PROP. 14'-24" R.C.P.
30
0
B
2
.2
9
9
.1
9
.1
5
8
.1
0
5
.4
8
LOT 20
PD-4
PROP. 10' D.E.
.3
5
H
F-1
B
F-2
F.F. EL. = +10.50 NGVD
F.F. EL. = +10.50 NGVD
LOT 15
TYPE "P" BOX (48" ROUND W/ TOP SLAB)
PER MDPWD. DETAIL SD 2.6
W/ U.S.F. 5105-6148 FRAME & HINGED GRATE
R.E.8.60
I.E. 4.50 E (PRB)
4.50 W (PRB)
4.50 N
PROPOSED DRAINAGE CONTROL STRUCTURE
(SEE DETAILS)
R.E.9.00
I.E. 4.00 S
3.00 N
G-4
H-1
2/
23/
2017
25'
11'-0" CONCRETE HEADWALL
PER FDOT INDEX 250
CAP OF HEADWALL EL. 6.08
I.E. 2.83
TYPE "P" BOX (48" ROUND W/ TOP SLAB)
PER MDPWD. DETAIL SD 2.6
W/ U.S.F. 5105-6148 FRAME & HINGED GRATE
R.E.8.60
I.E. 4.50 N
R/W
EXIST. 8" D.I.P. WATER MAIN
PER M-DWASD AS-BUILT
E-10600-2
8
.8
8
F-3
11'-0" CONCRETE HEADWALL
PER FDOT INDEX 250
CAP OF HEADWALL EL. 6.08
I.E. 2.83
H-2
4' DIA. DRAINAGE MANHOLE
W/ RING AND COVER PER MDPWD SD 4.4
R.E.8.24
I.E. 4.50 S
4.50 W (PRB)
EXIST. 8" C-900 PVC SAN. SEWER
PER M-DWASD AS-BUILT
ES-7461-2
37
8.
LOT 4
25'
B
B
A
.9
4
8
.6
8
PROP. 5' CONC. S/W
S.W. 158th
AVENUE
25'
25'
G-1
50' R/W
25'
TYPE "P" BOX (48" ROUND W/ TOP SLAB)
PER MDPWD. DETAIL SD 2.6
W/ U.S.F. 5105-6148 FRAME & HINGED GRATE
R.E.8.60
I.E. 4.50 W
H-3
TYPE "P" BOX (48" ROUND W/ TOP SLAB)
PER MDPWD. DETAIL SD 2.6
W/ U.S.F. 5105-6148 FRAME & HINGED GRATE
R.E.8.60
I.E. 4.50 E (PRB)
4.50 S
8
.7
3
50' R/W
74
8.
.9
7
MATCHLINE - SEE SHEET PD-4
G-2
G-3
REVISION
Designed by:
Drawn by:
Checked by:
AQ
RW
AQ
Date:
Date:
Date:
2/17
Approved by: ANTONIO QUEVEDO
NC.
HSQ GROUP,I
Engineers · Planners · Surveyors
2/17
2/17
Date: 2/23/2017
Registered Engineer Number
State of Florida
59471
5951 Northwest 173rd Drive, Suite 4
Miami, Florida 33015 · 786.534.3621
C26258 · LB7924
TYPE "P" BOX (48" ROUND W/ TOP SLAB)
PER MDPWD. DETAIL SD 2.6
W/ U.S.F. 5105-6148 FRAME & HINGED GRATE
R.E.8.60
I.E. 4.50 N (PRB)
4.50 S (PRB)
4.50 E,W
PROPOSED DRAINAGE CONTROL STRUCTURE
(SEE DETAILS)
R.E.9.00
I.E. 4.00 E
3.00 W
H-4
H-5
PROPOSED DRAINAGE CONTROL STRUCTURE
(SEE DETAILS)
R.E.9.00
I.E. 4.00 N
3.00 S
11'-0" CONCRETE HEADWALL
PER FDOT INDEX 250
CAP OF HEADWALL EL. 6.08
I.E. 2.83
PROJECT NUMBER
THE MEADOWS
1702-07
SHEET NUMBER
PAVING AND DRAINAGE PLAN
PD-3
Z:
\
HSQ Dade\
Ci
vi
lPr
oj
ect
s\
2017\
170207 The M eadows\
Dr
awi
ngs\
Const
r
uct
i
on Pl
ans\
170207PDP003.
dgn
S.
W .44th TERRACE
.2
8
.2
5
.9
4
.5
7
49
8.
Y D
PROP. 5' CONC. S/W
W
50'R/
20'
25'
ST.15'M DW ASD ESM T
EXI
PARK LAKES BY THE
MEADOWS PHASE THREE
(P.B. 155, PG. 21)
8
.8
6
9
.1
3
R/W
Y D
25'
W
50'R/
A
S TO P
R/W
BLOCK 1
48
8.
F.F. EL. = +10.50 NGVD
46
8.
F.F. EL. = +10.50 NGVD
9
1
.7
.5
8
8
EXIST. DRAINAGE INLET
R.E. 7.95
8
.9
9
9
.1
3
S
F.F. EL. = +10.50 NGVD
B
8
.6
2
.9
7
LOT 1
1
.5
8
6
.4
8
.2
5
.3
7
8
.8
2
LOT 2
H-2
DRAINAGE INLET SCHEDULE
EXIST. FIRE HYDRANT
PER M-DWASD AS-BUILT
E-10600-2
9
.0
4
SAWCUT AND MATCH EXISTING
PAVEMENT ELEVATIONS
EXIST. SAN. SEWER M.H.
PER MD-WASD ES-6570-4
R.E.8.76
I.E. 1.44 N
1.18 W
1.52 S
R/W
EXIST. 8" D.I.P. WATER MAIN
PER M-DWASD AS-BUILT
E-10600-2
12" WHITE CROSSWALK PER
FDOT INDEX 17346, 5' WIDE
0
.6
8
4
.2
8
7
.1
8
4
.2
8
2
.2
8
8
.7
2
LOT 3
MATCH EXISTING
PAVEMENT ELEVATIONS
25'
0
.2
8
4
.7
8
2
.5
8
2
.0
9
4
6
.5
.2
8
8
5
.4
8
8
.6
8
6
.7
8
EXIST. 12" C-900 PVC SAN. SEWER
PER M-DWASD AS-BUILT
ES-7185-4
H
9
.3
0
4
.6
8
4
.5
8
.7
7
.0
8
.2
8
5
.9
8
EXIST. SAN. SEWER M.H.
PER MD-WASD ES-6570-4
R.E.9.78
I.E. 2.04 N
(-) 1.36 E
(-) 2.08 S
H-1
.1
5
9
.1
3
PROP. HANDICAP RAMP
W/ TACTILE WARNING
PER FDOT INDEX 304
EXIST. FIRE HYDRANT
PER M-DWASD AS-BUILT
E-2805-7
R/W
WV
9
.6
7
STOP
.5
5
R1-1 "STOP SIGN"
(30" X 30")
2
.2
9
.7
5
PROP. VALLEY GUTTER
9
.5
7
9
.4
1
9.
28
PROP. 5' CONC. S/W
9
.2
6
WV
WV
R
.5
5
.6
5
.7
5
.8
7
99
8.
PROP. HANDICAP RAMP
W/ TACTILE WARNING
PER FDOT INDEX 304
R/W
9.
70
8
.9
8
.9
7
S
.5
8
.3
8
.7
6
.5
6
.8
6
.6
7
.8
6
.8
7
84
8.
PROP. 24' WHITE STOP BAR
W/ 25'-6" DBL. YELLOW
WV
9
.2
7
9.
52
'
6
3
G-1
PROP. 38'-18" H.D.P.E.
.0
9
.0
7
.4
5
.9
6
.7
6
.4
7
.9
6
.9
7
S
8.60
PROP. 22'-18" H.D.P.E.
R/W
MATCH EXISTING
PAVEMENT ELEVATIONS
PROP. 24' WHITE STOP BAR
W/ 25'-6" DBL. YELLOW
6
.3
8
.0
5
.9
5
.3
6
.3
6
.5
7
75
8.
3
6
'
8.80
PROP. 5' CONC. S/W
PROP. VALLEY GUTTER
G-2
1
.5
8
PROP. 5'-18" H.D.P.E.
& 25'-18" P.H.D.P.E. W/
4' WIDE TRENCH
8.60
R1-1 "STOP SIGN"
(30" X 30")
PROP. HANDICAP RAMP
W/ TACTILE WARNING
PER FDOT INDEX 304
.3
5
.0
5
PROP. 5'-18" H.D.P.E.
& 25'-18" P.H.D.P.E. W/
4' WIDE TRENCH
'
36
R
12" WHITE CROSSWALK PER
FDOT INDEX 17346, 5' WIDE
N.T.S.
STOP
PROP. 124'-18" H.D.P.E.
R1-1 "STOP SIGN"
(30" X 30")
KEY MAP
50' R/W
12" WHITE CROSSWALK PER
FDOT INDEX 17346, 5' WIDE
PROP. 24' WHITE STOP BAR
W/ 25'-6" DBL. YELLOW
.5
7
76
8.
EXIST. SAN. SEWER M.H.
PER MD-WASD ES-6570-4
R.E.8.93
I.E. (-) 2.72 N
(-) 2.67 E
(-) 2.69 W
25'
25'
.1
8
86
8.
R
LOT 18
F.F. EL. = +10.50 NGVD
PROP. HANDICAP RAMP
W/ TACTILE WARNING
PER FDOT INDEX 304
EXIST. 12" D.I.P. WATER MAIN
PER M-DWASD AS-BUILT
E-2805-7
BY
6
.5
9
.4
7
28
8.
F-3
LOT 10
EXIST. 10" D.I.P. SAN. SEWER
PER M-DWASD AS-BUILT
ES-6570-3
DATE
.6
8
.4
5
.3
5
.3
5
.4
5
.5
5
42
8.
PROP. 5' CONC. S/W
PROP. VALLEY GUTTER
PROP. 128'-18" H.D.P.E.
BARIMA ESTATES
(P.B. 139, PG. 13)
NO.
EXIST. SAN. SEWER M.H.
PER MD-WASD ES-6570-4
R.E.9.59
I.E. 0.56 W
0.55 E
F-2
R/W
EXIST. 8" D.I.P. SAN. SEWER
PER M-DWASD AS-BUILT
ES-6570-3
LOT 21
F.F. EL. = +10.50 NGVD
R/W
EXIST. SAN. SEWER M.H.
PER MD-WASD ES-6570-4
R.E.8.98
I.E. (-) 2.89 E
(-) 1.30 S
(-) 2.90 W
B
F.F. EL. = +10.50 NGVD
8.60
EXIST. 8" D.I.P. FORCE MAIN
PER M-DWASD AS-BUILT
ES-6570-4
C
LOT 9
F-1
EXIST. DRAINAGE INLET
R.E. 7.67
C
S
C
WV
.3
5
C
B
4.98 ACRES @
MEAN-LOW WATER LEVEL
8
.6
7
F.F. EL. = +10.50 NGVD
MATCH EXISTING
PAVEMENT ELEVATIONS
PROP. 5'-18" H.D.P.E.
& 25'-18" P.H.D.P.E. W/
4' WIDE TRENCH
25'
25'
WV
8
.5
7
25'
25'
.6
5
LOT 8
S.
W .44th STREET
50' R/W
B
0
.3
9
.3
5
2
.4
9
MATCHLINE - SEE SHEET PD-2
MATCHLINE - SEE SHEET PD-3
82
8.
74
8.
.9
7
K-1
LEGEND
.3
7
20
8.
PROP. 5'-18" H.D.P.E.
& 25'-18" P.H.D.P.E. W/
4' WIDE TRENCH
8
.4
0
.3
5
PROP. 5'-18" H.D.P.E.
& 25'-18" P.H.D.P.E. W/
4' WIDE TRENCH
S
0
LOT 14
F.F. EL. = +10.50 NGVD
F.F. EL. = +10.50 NGVD
8
.6
9
25'
60
50' R/W
25'
50' R/W
30
PROPOSED ASPHALT, LIMEROCK &
SUBGRADE (SEE SHEET PD-5 FOR DETAILS)
.2
8
PROP. 5' CONC. S/W
LOT 5
EXISTING ASPHALT TO REMAIN
41
8.
EXIST. SAN. SEWER M.H.
PER MD-WASD ES-6570-4
R.E.8.51
I.E. (-) 1.99 N
(-) 1.92 E
(-) 2.02 W
I-1
.0
5
8.
56
15
8.
EXIST. DRAINAGE INLET
R.E. 7.83
PROP. 5'-18" H.D.P.E.
& 25'-18" P.H.D.P.E. W/
4' WIDE TRENCH
.0
5
PROP. 5'-18" H.D.P.E.
& 25'-18" P.H.D.P.E. W/
4' WIDE TRENCH
FEET
EXISTING ASPHALT TO BE MILLED &
RESURFACED
(SEE SHEET PD-5 FOR DETAILS)
25'
8
.5
5
SCALE: 1"=30'
25'
R/W
R/W
.0
5
8
.5
8
R/W
.3
5
.0
5
MATCH EXISTING
PAVEMENT ELEVATIONS
B
PROP. VALLEY GUTTER
8
.2
9
.0
8
EXIST. 8" D.I.P. FORCE MAIN
PER M-DWASD AS-BUILT
ES-6570-3
B
DRAINAGE INLET SCHEDULE
8
.2
9
S
.6
7
9
.0
0
R/W
EXIST. SAN. SEWER M.H.
PER MD-WASD ES-7461.2
R.E.8.69
I.E. (-) 0.26 E
(-) 0.29 W
8
.6
5
PROP. 5' CONC. S/W
MATCH EXISTING
PAVEMENT ELEVATIONS
F.F. EL. = +10.50 NGVD
S.
W .44th TERRACE
8
.7
1
8
.2
3
K-1
EXIST. DRAINAGE INLET
R.E. 7.77
8
.1
1
L-1
8
.5
3
PARK LAKES BY THE
MEADOWS PHASE THREE
(P.B. 155, PG. 21)
PD-1
.1
5
8
.3
9
.2
5
PD-2
2
.3
8
LOT 8
LOT 11
F.F. EL. = +10.50 NGVD
F.F. EL. = +10.50 NGVD
PD-3
3
.7
8
7
.9
8
2
.8
8
3
6
'
R
9
.4
0
1
.3
8
5
.9
8
8
.7
8
0
.5
8
8
.0
8
3
.7
7
3
.3
8
7
.9
7
EXIST. 30" D.I.P. WATER MAIN
PER M-DWASD AS-BUILT
E-10600-2
47
9.
C
EXIST. SAN. SEWER M.H.
PER MD-WASD ES-7461-2
R.E.9.28
I.E. 1.08 N
1.00 W
1
.3
8
40'
89
8.
37
9.
28
9.
8
.5
8
3
.7
8
WV
W
80'R/
81
8.
S
8
.1
9
PROP. 24' WHITE STOP BAR
W/ 25'-6" DBL. YELLOW
8
.8
7
8
.9
7
WV
12
9.
7
.7
8
9
.0
2
6
.1
9
7
.0
9
8
.5
7
S.W. 157tH AVENUE
8
.3
6
'
6
3
7
.4
2
0
.6
8
6
.1
9
WV
WV
8
.6
7
R
8
.0
0
7
.9
4
16
8.
5
.6
8
PROP. 24' WHITE STOP BAR
W/ 25'-6" DBL. YELLOW
12" WHITE CROSSWALK PER
FDOT INDEX 17346, 10' WIDE
8.8
8
S
WV
C
60
8.
8
.4
4
12" WHITE CROSSWALK PER
FDOT INDEX 17346, 10' WIDE
EXIST. 12" D.I.P. FORCE MAIN
PER M-DWASD AS-BUILT
ES-6570-3
R/W
NO.
DATE
BY
REVISION
Designed by:
Drawn by:
Checked by:
AQ
RW
AQ
Date:
Date:
Date:
2/17
Approved by: ANTONIO QUEVEDO
NC.
HSQ GROUP,I
Engineers · Planners · Surveyors
2/17
2/17
Date: 2/23/2017
Registered Engineer Number
State of Florida
59471
5951 Northwest 173rd Drive, Suite 4
Miami, Florida 33015 · 786.534.3621
C26258 · LB7924
PROJECT NUMBER
THE MEADOWS
1702-07
SHEET NUMBER
PAVING AND DRAINAGE PLAN
PD-4
Z:
\
HSQ Dade\
Ci
vi
lPr
oj
ect
s\
2017\
170207 The M eadows\
Dr
awi
ngs\
Const
r
uct
i
on Pl
ans\
170207PDP004.
dgn
STOP
H
R/W
8
.5
8
8
.
7
2
8
.7
3
20
9.
PROP. VALLEY GUTTER
EXIST. DRAINAGE INLET
R.E. 8.53
40'
8.
86
8
.3
0
1
.5
8
EXIST. SAN. SEWER M.H.
PER MD-WASD ES-7461-2
R.E.9.49
I.E. 1.92 N
1.84 E
8
.
5
9
8
.6
9
R1-1 "STOP SIGN"
(30" X 30")
EXIST. 8" P.V.
PER M-DWASD AS-BUILT
ES-6570-3
Y D
WV
WV
Y D
EXIST. R1-1 STOP SIGN
(TO REMAIN)
8
.6
9
EXIST. DRAINAGE INLET
R.E. 8.60
(TO BE REMOVED)
40'
8
.4
5
9
.3
8
50' R/W
EXIST. FIRE HYDRANT
PER M-DWASD AS-BUILT
E-2805-7
9
.
0
3
8
.
6
1
J-1
W
80'R/
8
.4
4
5
.3
8
LOT 10
F.F. EL. = +10.50 NGVD
6
0
.
9
8
.5
2
6
.6
8
7
.3
8
2
.6
8
LOT 9
F.F. EL. = +10.50 NGVD
8
.5
9
PROP. 5'-18" H.D.P.E.
& 50'-18" P.H.D.P.E. W/
4' WIDE TRENCH
25'
25'
EXIST. FIRE HYDRANT
PER M-DWASD AS-BUILT
E-10600-2
H
L-1
EXIST. DRAINAGE INLET
R.E. 8.41
(TO BE REMOVED)
N.T.S.
.2
5
.9
7
.2
5
S
PROP. 5'-18" H.D.P.E.
& 50'-18" P.H.D.P.E. W/
4' WIDE TRENCH
KEY MAP
8
.5
8
.8
4
1
.5
5
8
.5
0
25
8.
3
.6
8
EXIST. DRAINAGE INLET
R.E. 8.04
PD-4
8
.3
2
9
.4
8
EXIST. SAN. SEWER M.H.
PER MD-WASD ES-6570-4
R.E.8.53
I.E. 4.60 S
(-) 4.55 W
2/
23/
2017
.7
7
8
.3
4
8
.5
6
.3
7
8
.5
2
4
.4
8
EXIST. DRAINAGE INLET
R.E. 7.66
40'
TYPE "P" BOX (48" ROUND W/ TOP SLAB)
PER MDPWD. DETAIL SD 2.6
W/ U.S.F. 5105-6148 FRAME & HINGED GRATE
R.E.8.60
I.E. 4.50 W (PRB)
8
.2
6
8
.5
2
TYPE "P" BOX (48" ROUND W/ TOP SLAB)
PER MDPWD. DETAIL SD 2.6
W/ U.S.F. 5105-6148 FRAME & HINGED GRATE
R.E.8.60
I.E. 4.50 E (PRB)
4.50 W (PRB)
BARIMA ESTATES
(P.B. 139, PG. 13)
TYPE "P" BOX (48" ROUND W/ TOP SLAB)
PER MDPWD. DETAIL SD 2.6
W/ U.S.F. 5105-6148 FRAME & HINGED GRATE
R.E.8.60
I.E. 4.50 W (PRB)
EXIST. 8" C-900 PVC SAN. SEWER
PER M-DWASD AS-BUILT
ES-7461-2
.9
4
B
6
.5
8
B
8
.0
2
J-1
8
.2
1
.7
7
LOT 12
F.F. EL. = +10.50 NGVD
8.
10
.9
4
.3
5
LOT 7
EXIST. 8" D.I.P. WATER MAIN
PER M-DWASD AS-BUILT
E-10600-2
8
.1
3
PROP. 5' CONC. S/W
F.F. EL. = +10.50 NGVD
TYPE "P" BOX (48" ROUND W/ TOP SLAB)
PER MDPWD. DETAIL SD 2.6
W/ U.S.F. 5105-6148 FRAME & HINGED GRATE
R.E.8.60
I.E. 4.50 E (PRB)
4.50 W (PRB)
PROP. VALLEY GUTTER
BLOCK 1
.2
7
F.F. EL. = +10.50 NGVD
.3
5
8
.7
9
8
.5
8
EXIST. 12" D.I.P. WATER MAIN
PER M-DWASD AS-BUILT
E-2805-7
LOT 13
.8
7
S.
W .45th TERRACE
3
.7
8
EXIST. 10" D.I.P. SAN. SEWER
PER M-DWASD AS-BUILT
ES-6570-3
LOT 6
I-1
PAVEMENT NOTES
CENTERLINE OF GUTTER
50' R/W
1. THE PAVEMENT SURFACE SHALL BE ASPHALTIC CONCRETE. A TACK COAT SHALL BE
5' S/W
8'
2'
10' DRIVE LANE
10' DRIVE LANE
2'
8'
ASPHALT TO BE INSTALLED
1/4 INCH ABOVE LIP OF GUTTER
SOD TO BE INSTALLED
2" BELOW LIP OF GUTTER
5' S/W
12"
APPLIED BETWEEN BOTH PAVEMENT COURSES. REFER TO SECTIONS FOR ASPHALT
12"
TYPE AND THICKNESS.
R= 3/4"
2. THE LIMEROCK BASE SHALL BE 8 INCHES THICK. REFER TO PAVEMENT SECTION
ALTERNATES. THE LIMEROCK MATERIAL SHALL HAVE A MINIMUM LIMEROCK BEARING
R= 3/4"
A DENSITY EQUAL TO OR GREATER THAN 98% OF THE MAXIMUM DRY DENSITY PER
2
% MAX.
% MAX.
2
CONCRETE SIDEWALK
2.0% MAX. CROSS-SLOPE
(SEE DETAILS)
A.A.S.H.T.O. T-180 SPECIFICATIONS.
4" LIMEROCK PAD
4"
4" LIMEROCK GUTTER PAD WITH
L.B.R.= 100 AND COMPACTED
TO 98% MAX. DRY DENSITY
2'-0"
3,000 P.S.I. CONCRETE
CONCRETE SIDEWALK
2.0% MAX. CROSS-SLOPE
(SEE DETAILS)
SUB-GRADE
(SEE NOTES)
PROP. VALLEY GUTTER
(SEE DETAIL)
RATIO (L.B.R.) VALUE OF 100. THE LIMEROCK MATERIAL SHALL BE COMPACTED TO
7 1/2"
6 1/4"
6"
2" ASPHALT PAVEMENT
(SEE NOTES)
3. THE SUBGRADE SHALL BE 12 INCHES THICK. REFER TO PAVEMENT SECTION
ALTERNATES. THE SUBGRADE MATERIAL SHALL HAVE A MINIMUM LIMEROCK
PER AASHTO T-180
BEARING RATIO (L.B.R.) VALUE OF 40. THE SUBGRADE MATERIAL
SHALL BE COMPACTED TO A DENSITY EQUAL TO OR GREATER THAN 98% OF THE
MAXIMUM DRY DENSITY PER A.A.S.H.T.O. T-180 SPECIFICATIONS.
LIMEROCK BASE
(SEE NOTES)
PROP. VALLEY GUTTER
(SEE DETAIL)
CONCRETE VALLEY GUTTER DETAIL
N.T.S. - PER F.D.O.T. INDEX 300
4. THE LIMEROCK AND SUBGRADE COURSES SHALL NOT BE CONSTRUCTED UNTIL ALL
UTILITY INSTALLATIONS UNDER PAVEMENT AREAS HAVE BEEN COMPLETED, TESTED
AND ACCEPTED. ANY PAVEMENT CONSTRUCTION PRIOR TO THIS REQUIREMENT
SECTION A-A
SHALL BE CONDUCTED AT THE CONTRACTOR'S OWN RISK AND ANY REQUIRED
OVERALL WIDTH
REPAIRS WILL BE THE CONTRACTOR'S SOLE RESPONSIBILITY AND EXPENSE.
(VARIES - SEE PLAN)
N.T.S.
1
/
4
"
/
F
T
.SL
OPE
5. THE PRIME AND TACK COATS SHALL CONFORM TO THE FLORIDA DEPARTMENT OF
TRANSPORTATION (SECTIONS 300-1 THRU 300-7) SPECIFICATIONS. THE PRIME COAT
50' R/W
EXIST. AREA VARIES
SHALL BE APPLIED AT A RATE OF 0.25 GALLONS PER SQUARE YARD OF PAVEMENT.
EXIST. DRIVE LANE VARIES
10' DRIVE LANE
2'
8'
5' S/W
CONCRETE SIDEWALK
6" THICK COMPACTED SUB-GRADE
4" THICK (ON-SITE)
6. PERIODIC DENSITY TESTING SHALL BE CONDUCTED AFTER BOTH SUBGRADE AND
MATERIAL UNDER ALL SIDEWALKS
6" THICK (OFF-SITE)
LIMEROCK BASE COURSES HAVE BEEN COMPLETED. THE TOTAL NUMBER AND EXACT
LOCATIONS OF THE TESTS SHALL BE DETERMINED BY EITHER THE ENGINEER-OFRECORD OR GOVERNMENT INSPECTOR. THE MINIMUM AMOUNT OF TESTING SHALL
GENERAL NOTES
BE BASED ON ONE (1) DENSITY TEST PER 5,000 SQUARE FEET OF PAVEMENT AREA.
1. PROVIDE 1/8" CONSTRUCTION JOINTS AT 5' O/C,
2" ASPHALT PAVEMENT
(SEE NOTES)
MILL 1" OF EXIST.
ASPHALT PAVEMENT
& RESURFACE
WITH FC-9.5
MINIMUM DEPTH 1/2".
2. PROVIDE 1/2" EXPANSION JOINTS WITH NON-RISING FILLER AT 20' O/C,
2
% MAX.
7. THE FIRST LIFT OF THE ASPHALTIC CONCRETE PAVEMENT SHALL BE APPLIED
TO RUN FULL DEPTH OF SLAB.
3/4 INCH BELOW THE LIP OF CURB, WHERE APPLICABLE. THE SECOND (FINAL) LIFT
LIMEROCK BASE
(SEE NOTES)
4. CURE ALL CONCRETE WITH CLEAN SAND, PLASTIC MEMBRANE, OR OTHER
SHALL NOT BE APPLIED UNTIL EITHER THE CLIENT, ENGINEER-OF-RECORD AND/OR
APPROVED METHOD.
CONCRETE SIDEWALK
2.0% MAX. CROSS-SLOPE
(SEE DETAILS)
EXIST. CURB
SHALL EXTEND 1/4 INCH ABOVE THE LIP OF CURB. THE FINAL LIFT OF ASPHALT
GOVERNMENT AGENCY DETERMINES THAT SUBSTANTIAL PROJECT CONSTRUCTION
HAS BEEN COMPLETED.
PROP. VALLEY GUTTER
(SEE DETAIL)
2/23/2017
EXIST. CONCRETE
SIDEWALK
3. CONCRETE TO BE 2,500 P.S.I. IN 28 DAYS.
8. ALL EXISTING ORGANIC AND DELETERIOUS MATERIALS WITHIN THE RIGHT-OF-WAY
SUB-GRADE
(SEE NOTES)
AND ON-SITE PAVEMENT AREAS ARE TO BE REMOVED TO THEIR FULL DEPTH AND
CONCRETE SIDEWALK DETAILS
REPLACED WITH APPROVED SUITABLE MATERIAL, UNLESS AN ALTERNATIVE METHOD
IS RECOMMENDED BY A CERTIFIED GEOTECHNICAL ENGINEER. THE DETERMINATION
N.T.S.
SECTION B-B
OF ORGANIC AND UNSUITABLE MATERIALS SHALL BE BASED ON F.D.O.T. STANDARDS.
N.T.S.
9. ALL EXISTING PAVEMENT CONNECTIONS AND REPAIRS SHALL HAVE A STRAIGHT
LAKE TOP OF BANK &
REAR LOT LINE
SAW-CUT EDGE PRIOR TO APPLYING NEW ASPHALT PAVEMENT.
10. ONCE FINAL LIFT OF ASPHALT HAS BEEN APPLIED, ALL PERMANENT CONTROL POINTS,
35.4' TO LAKE DEEP CUT LINE
REAR YARD AREA
REFERENCE MARKERS, VALVES, INLET AND MANHOLE RIMS SHALL BE FIELD ADJUSTED
TO BE FLUSH WITH FINAL ASPHALT GRADES.
5' SAFETY
SHELF
30.4' TO SAFETY SHELF EDGE
+8.60
18.4'
4 MAX.
MATCH EXISTING
1
+4.00
GRADE
3'
2" ASPHALT (2 LIFTS)
12"
SAWCUT AREA
1" SP 12.5 - FIRST
EXISTING ASPHALT
1" FC 9.5 - FINAL
PAVEMENT
2" ASPHALT PAVEMENT
+1.00
40'M AX.DEPTH
10'M I
N.DEPTH
8" NEW LIMEROCK
6"
+1.00
BASE
EXISTING
8" LIMEROCK
LIMEROCK
12" NEW
SUBGRADE
REMOVE 6" OF EXISTING
SLOPE 2H:1V MAX. OR
ANGLE OF REPOSE
LIMEROCK BASE AND REPLACE
12" SUBGRADE
WITH NEW LIMEROCK
EXISTING
SUBGRADE
LAKE BOTTOM
TYPICAL ASPHALT SECTION
SECTION C-C
N.T.S.
N.T.S.
REVISION
Designed by:
A.Q.
Date:
2/17
N
I
E
L
Approved
by: ANTONIO QUEVEDO
No 59471
2/17
F
STATE OF
Registered
Engineer Number
F
A
LO
D
ofR
Florida
E State
I
I
S
G
SI
ONAL EN
Date: 2/23/2017
NC.
HSQ GROUP,I
Engineers · Planners · Surveyors
ER
Date:
2/17
O
A.Q.
Date:
PR
Checked by:
R.W.
E
Drawn by:
N
BY
A
DATE
O
NO.
O QUEV
NI
E
O
D
T
CEN S
59471
5951 Northwest 173rd Drive, Suite 4
Miami, Florida 33015 · 786.534.3621
C26258 · LB7924
TYPICAL PAVEMENT CONNECTION DETAIL
N.T.S.
PROJECT NUMBER
THE MEADOWS
1702-07
SHEET NUMBER
PAVING AND DRAINAGE DETAILS
PD-5
Z:
\
HSQ Dade\
Ci
vi
lPr
oj
ect
s\
2017\
170207 The M eadows\
Dr
awi
ngs\
Const
r
uct
i
on Pl
ans\
170207PDD001.
dgn
MEAN-LOW WATER LEVEL
ELEVATION = +4.00 NGVD.