You can copy from here when filling out the rest of the page.
Bay County. CADH, LLC, Panama City, Florida.
PROJECT PURPOSE:
Basic: Residential Development.
Overall: Construction of a single-family residential subdivision with associated infrastructure within Lynn Haven, Bay County, Florida.
TO WHOM IT MAY CONCERN: The Jacksonville District of the U.S. Army Corps of Engineers (Corps) has received an application for a Department of the Army permit pursuant to Section 404 of the Clean Water Act (33 U.S.C. §1344) as described below:
APPLICANT: Robert N. Humble
CADH, LLC
4116 Highway 231 North
Panama City, Florida 32404
WATERWAY AND LOCATION: The project would affect waters of the United States including wetlands associated with construction of an 85-lot residential subdivision and associated infrastructure. The project site is located on the east side of Highway 389 approximately 1.5 miles north of Baldwin Road in Lynn Haven, Bay County, Florida.
Directions to the site are as follows: From Highway 231, turn north on N East Avenue. The property is approximately 2 miles north of the intersection of Highway 231 and N East Avenue on the east side of the road, approximately 100 linear feet south of Dundee Lane.
APPROXIMATE CENTRAL COORDINATES: Latitude 30.223351°
Longitude -85.626123°
PROJECT PURPOSE:
Basic: Residential Development.
Overall: Construction of a single-family residential subdivision with associated infrastructure within Lynn Haven, Bay County, Florida.
EXISTING CONDITIONS: The wetlands consist of hydric pine and mixed hardwood forested freshwater systems. The onsite vegetation consists of Pinus elliottii (slash pine), Magnolia virginiana (sweet bay), Taxodium distichum (cypress), Cyrilla racemiflora (titi), and Hypericum chapmannii (St. John’s wort). The existing area surrounding the project area consists of mixed residential development and undeveloped forested land.
PROPOSED WORK: The applicant seeks authorization to place fill material in 3.217 acres of jurisdictional wetlands associated with construction of an 85-lot residential subdivision, stormwater management facilities and recreational facilities.
AVOIDANCE AND MINIMIZATION INFORMATION – The applicant has provided the following information in support of efforts to avoid and/or minimize impacts to the aquatic environment:
The applicant states that to minimize impacts to downstream wetlands, the stormwater management feature has been designed to discharge at existing ground elevation.
COMPENSATORY MITIGATION – The applicant has offered the following compensatory mitigation plan to offset unavoidable functional loss to the aquatic environment:
The applicant proposes to purchase 1.65 credits from the Sweetwater Mitigation Bank.
CULTURAL RESOURCES:
The Corps is not aware of any known historic properties within the permit area. By copy of this public notice, the Corps is providing information for review. Our final determination relative to historic resource impacts is subject to review by and coordination with the State Historic Preservation Officer and those federally recognized tribes with concerns in Florida and the Permit Area.
ENDANGERED SPECIES:
The Corps has determined the proposed project may affect, but is not likely to adversely affect the Eastern Indigo Snake or its designated critical habitat. The Corps will request U.S. Fish and Wildlife Service concurrence with this determination pursuant to Section 7 of the Endangered Species Act.
ESSENTIAL FISH HABITAT (EFH): This notice initiates consultation with the National Marine Fisheries Service on EFH as required by the Magnuson-Stevens Fishery Conservation and Management Act 1996. Our initial determination is that the proposed action would not have a substantial adverse impact on EFH or Federally managed fisheries in the St. Andrews Bay watershed. Our final determination relative to project impacts and the need for mitigation measures is subject to review by and coordination with the National Marine Fisheries Service.
NOTE: This public notice is being issued based on information furnished by the applicant. This information has not been verified or evaluated to ensure compliance with laws and regulation governing the regulatory program. The jurisdictional line has not been verified by Corps personnel.
AUTHORIZATION FROM OTHER AGENCIES: Water Quality Certification may be required from the Florida Department of Environmental Protection and/or one of the state Water Management Districts.
COMMENTS regarding the potential authorization of the work proposed should be submitted in writing to the attention of the District Engineer through the Panama City Permits Section, 1002 West 23rd Street, Suite 350, Panama City, Florida 32405 within 30 days from the date of this notice.
The decision whether to issue or deny this permit application will be based on the information received from this public notice and the evaluation of the probable impact to the associated wetlands. This is based on an analysis of the applicant's avoidance and minimization efforts for the project, as well as the compensatory mitigation proposed.
QUESTIONS concerning this application should be directed to the project manager, Tracey L Wheeler, in writing at the Panama City Permits Section, 1002 West 23rd Street, Suite 350, Panama City, Florida 32405; by electronic mail at tracey.l.wheeler@usace.army.mil; by facsimile transmission at (850)872-0231; or, by telephone at (850)763-0717 ex 24.
IMPACT ON NATURAL RESOURCES: Coordination with U.S. Fish and Wildlife Service, Environmental Protection Agency (EPA), the National Marine Fisheries Services, and other Federal, State, and local agencies, environmental groups, and concerned citizens generally yields pertinent environmental information that is instrumental in determining the impact the proposed action will have on the natural resources of the area.
EVALUATION: The decision whether to issue a permit will be based on an evaluation of the probable impact including cumulative impacts of the proposed activity on the public interest. That decision will reflect the national concern for both protection and utilization of important resources. The benefits, which reasonably may be expected to accrue from the proposal, must be balanced against its reasonably foreseeable detriments. All factors which may be relevant to the proposal will be considered including cumulative impacts thereof; among these are conservation, economics, esthetics, general environmental concerns, wetlands, historical properties, fish and wildlife values, flood hazards, floodplain values, land use, navigation, shoreline erosion and accretion, recreation, water supply and conservation, water quality, energy needs, safety, food, and fiber production, mineral needs, considerations of property ownership, and in general, the needs and welfare of the people. Evaluation of the impact of the activity on the public interest will also include application of the guidelines promulgated by the Administrator, EPA, under authority of Section 404(b) of the Clean Water Act or the criteria established under authority of Section 102(a) of the Marine Protection Research and Sanctuaries Act of 1972. A permit will be granted unless its issuance is found to be contrary to the public interest.
The US Army Corps of Engineers (Corps) is soliciting comments from the public; Federal, State, and local agencies and officials; Indian Tribes; and other Interested parties in order to consider and evaluate the impacts of this proposed activity. Any comments received will be considered by the Corps to determine whether to issue, modify, condition, or deny a permit for this proposal. To make this determination, comments are used to assess impacts to endangered species, historic properties, water quality, general environmental effects, and the other public interest factors listed above. Comments are also used to determine the need for a public hearing and to determine the overall public interest of the proposed activity.
COASTAL ZONE MANAGEMENT CONSISTENCY: In Florida, the State approval constitutes compliance with the approved Coastal Zone Management Plan.
REQUEST FOR PUBLIC HEARING: Any person may request a public hearing. The request must be submitted in writing to the District Engineer within the designated comment period of the notice and must state the specific reasons for requesting the public hearing.
DEPARTMENT OF THE ARMY
JACKSONVILLE DISTRICT CORPS OF ENGINEERS
1002 WEST 23RD STREET, SUITE 350
PANAMA CITY, FLORIDA 32405
October 10, 2017
REPLY TO
ATTENTION OF
Regulatory Division
North Branch
Panama City Permits Section
PUBLIC NOTICE
Permit Application No. SAJ-2017-01757(SP-TLW)
TO WHOM IT MAY CONCERN: The Jacksonville District of the U.S. Army Corps of
Engineers (Corps) has received an application for a Department of the Army permit
pursuant to Section 404 of the Clean Water Act (33 U.S.C. §1344) as described below:
APPLICANT: Robert N. Humble
CADH, LLC
4116 Highway 231 North
Panama City, Florida 32404
WATERWAY AND LOCATION: The project would affect waters of the United States
including wetlands associated with construction of an 85-lot residential subdivision and
associated infrastructure. The project site is located on the east side of Highway 389
approximately 1.5 miles north of Baldwin Road in Lynn Haven, Bay County, Florida.
Directions to the site are as follows: From Highway 231, turn north on N East Avenue.
The property is approximately 2 miles north of the intersection of Highway 231 and N
East Avenue on the east side of the road, approximately 100 linear feet south of
Dundee Lane.
APPROXIMATE CENTRAL COORDINATES: Latitude 30.223351°
Longitude -85.626123°
PROJECT PURPOSE:
Basic: Residential Development.
Overall: Construction of a single-family residential subdivision with associated
infrastructure within Lynn Haven, Bay County, Florida.
EXISTING CONDITIONS: The wetlands consist of hydric pine and mixed hardwood
forested freshwater systems. The onsite vegetation consists of Pinus elliottii (slash
pine), Magnolia virginiana (sweet bay), Taxodium distichum (cypress), Cyrilla
racemiflora (titi), and Hypericum chapmannii (St. John's wort). The existing area
surrounding the project area consists of mixed residential development and
undeveloped forested land.
PROPOSED WORK: The applicant seeks authorization to place fill material in 3.217
acres of jurisdictional wetlands associated with construction of an 85-lot residential
subdivision, stormwater management facilities and recreational facilities.
AVOIDANCE AND MINIMIZATION INFORMATION The applicant has provided the
following information in support of efforts to avoid and/or minimize impacts to the
aquatic environment:
The applicant states that to minimize impacts to downstream wetlands, the stormwater
management feature has been designed to discharge at existing ground elevation.
COMPENSATORY MITIGATION The applicant has offered the following
compensatory mitigation plan to offset unavoidable functional loss to the aquatic
environment:
The applicant proposes to purchase 1.65 credits from the Sweetwater Mitigation Bank.
CULTURAL RESOURCES:
The Corps is not aware of any known historic properties within the permit area. By copy
of this public notice, the Corps is providing information for review. Our final
determination relative to historic resource impacts is subject to review by and
coordination with the State Historic Preservation Officer and those federally recognized
tribes with concerns in Florida and the Permit Area.
ENDANGERED SPECIES:
The Corps has determined the proposed project may affect, but is not likely to adversely
affect the Eastern Indigo Snake or its designated critical habitat. The Corps will request
U.S. Fish and Wildlife Service concurrence with this determination pursuant to Section 7
of the Endangered Species Act.
ESSENTIAL FISH HABITAT (EFH): This notice initiates consultation with the National
Marine Fisheries Service on EFH as required by the Magnuson-Stevens Fishery
Conservation and Management Act 1996. Our initial determination is that the proposed
action would not have a substantial adverse impact on EFH or Federally managed
fisheries in the St. Andrews Bay watershed. Our final determination relative to project
impacts and the need for mitigation measures is subject to review by and coordination
with the National Marine Fisheries Service.
NOTE: This public notice is being issued based on information furnished by the
applicant. This information has not been verified or evaluated to ensure compliance
with laws and regulation governing the regulatory program. The jurisdictional line has
not been verified by Corps personnel.
2
AUTHORIZATION FROM OTHER AGENCIES: Water Quality Certification may be
required from the Florida Department of Environmental Protection and/or one of the
state Water Management Districts.
COMMENTS regarding the potential authorization of the work proposed should be
submitted in writing to the attention of the District Engineer through the Panama City
Permits Section, 1002 West 23rd Street, Suite 350, Panama City, Florida 32405 within
30 days from the date of this notice.
The decision whether to issue or deny this permit application will be based on the
information received from this public notice and the evaluation of the probable impact to
the associated wetlands. This is based on an analysis of the applicant's avoidance and
minimization efforts for the project, as well as the compensatory mitigation proposed.
QUESTIONS concerning this application should be directed to the project manager,
Tracey L Wheeler, in writing at the Panama City Permits Section, 1002 West 23rd Street,
Suite 350, Panama City, Florida 32405; by electronic mail at
tracey.l.wheeler@usace.army.mil; by facsimile transmission at (850)872-0231; or, by
telephone at (850)763-0717 ex 24.
IMPACT ON NATURAL RESOURCES: Coordination with U.S. Fish and Wildlife
Service, Environmental Protection Agency (EPA), the National Marine Fisheries
Services, and other Federal, State, and local agencies, environmental groups, and
concerned citizens generally yields pertinent environmental information that is
instrumental in determining the impact the proposed action will have on the natural
resources of the area.
EVALUATION: The decision whether to issue a permit will be based on an evaluation of
the probable impact including cumulative impacts of the proposed activity on the public
interest. That decision will reflect the national concern for both protection and utilization
of important resources. The benefits, which reasonably may be expected to accrue from
the proposal, must be balanced against its reasonably foreseeable detriments. All
factors which may be relevant to the proposal will be considered including cumulative
impacts thereof; among these are conservation, economics, esthetics, general
environmental concerns, wetlands, historical properties, fish and wildlife values, flood
hazards, floodplain values, land use, navigation, shoreline erosion and accretion,
recreation, water supply and conservation, water quality, energy needs, safety, food,
and fiber production, mineral needs, considerations of property ownership, and in
general, the needs and welfare of the people. Evaluation of the impact of the activity on
the public interest will also include application of the guidelines promulgated by the
Administrator, EPA, under authority of Section 404(b) of the Clean Water Act or the
criteria established under authority of Section 102(a) of the Marine Protection Research
and Sanctuaries Act of 1972. A permit will be granted unless its issuance is found to be
contrary to the public interest.
3
The US Army Corps of Engineers (Corps) is soliciting comments from the public;
Federal, State, and local agencies and officials; Indian Tribes; and other Interested
parties in order to consider and evaluate the impacts of this proposed activity. Any
comments received will be considered by the Corps to determine whether to issue,
modify, condition, or deny a permit for this proposal. To make this determination,
comments are used to assess impacts to endangered species, historic properties, water
quality, general environmental effects, and the other public interest factors listed above.
Comments are also used to determine the need for a public hearing and to determine
the overall public interest of the proposed activity.
COASTAL ZONE MANAGEMENT CONSISTENCY: In Florida, the State approval
constitutes compliance with the approved Coastal Zone Management Plan.
REQUEST FOR PUBLIC HEARING: Any person may request a public hearing. The
request must be submitted in writing to the District Engineer within the designated
comment period of the notice and must state the specific reasons for requesting the
public hearing.
4
ANDRE
S PLANTATION SUBDIVISION
""
-
G iJ
lp
. ~·
-
"""'
0
DSC ·O~
,<'>
LYNN HAVEN, FLORIDA
\
"'"
·· 01..
·~
"
~
()
-· ·-
0
\)!;
·-"·""
llMTIN
·~·
·=
~ w·
. .""'.
""""
~"
""
"'"""·
.·
~
,
~·
<
I
RELEASED FOR
PERMITTING
PURPOSES ONLY
Q
Q
Q
oi
'"
~
MAY 2017
PROJECT No. 57916-B
DRAWING INDEX
ADDRESS
LAT "' N.30· 14'29 "
LON ~ ws5·35'43"
PREPARED BY:
VICINITY MAP
No. - TITLE
S1 - EXISTING CONDITIONS SURVEY SHEET 1 OF 2
S2 - EXISTING CONDITIONS SURVEY SHEET 2 OF 2
1 - OVERALL SITE PLAN
2 - SITE PLAN WITH AERIAL
3 - OVERALL SUBDIVISION LOT LAYOUT WITH BUILDABLE LOT AREA
4 - SITE GEOMETRY PLAN - NORTH
5 - SITE GEOMETRY PLAN - SOUTH
6 - UTILITY MASTER PLAN
7 - STORMWATER MASTER PLAN
8 - CASON DRIVE PLAN & PROFILE
9 - CALEIGH CIRCLE PLAN & PROFILE
10 - CALEIGH CIRCLE PLAN & PROFILE
11 - STORMWATER DRAINAGE EASEMENTS
12 - STORMWATER DETAILS SHEET
13 - OFFSITE UTILITY ROUTING AND TURN LANES
14 - OFFSITE UTILITY ROUTING AND TURN LANES
15 - STANDARD NOTES
16 - CONSTRUCTION DETAILS
17 - STORMWATER DETAILS
18 - WATER UTILITY DETAILS
19- SANITARY UTILITY DETAILS
20 - SANITARY & REUSE UTILITY DETAILS
21 - LIFT STATION DETAILS
22 LIFT STATION DETAILS
23 - EROSION CONTROL DETAILS
24 - NPDES
z
0
(/)
>
DESCRIP TIONo
THE E AS T H A LF O F THE NOR THE AS T QUAR TE R O F THE SOU THE AS T QUAR TE R O F S EC T ION 15,
T OWNS HI P 3 SOU TH , RANG E 14 WES T, BAY COUN T Y, FLOR IDA ANO THE SOU TH H A LF O F THE
NOR TH WES T QUAR TER O F THE NOR THE AS T QUAR TE R O F THE SOU THE AS T QUAR TE R O F S EC TI ON 15.
T OWNS HIP 3 SOU TH , RANG E 14 WES T, BAY COUN T Y, FLOR IDA , LE SS AND E XC E P T TH A T POR TI ON
T AK EN F OR R IG HT O F WAY FOR COUN T Y ROAD 389. SA ID L ANDS CON TA IN ING 2 4 .8 4 07 ACR ES MOR E
OR LE SS.
I
I'
'
''
I'
I'
I
I
I
/
I
I
I'
I'
I
_;_ I' ·
I
II
I
I
'
I'
'
--1,1·,SEl -,;:;f
.:..llE ··
N!l 1~~~io,<-.-:;E '.:C'1.'7
I
'
I
I'
I
II
I
'
NOR TH LI NE O F THE SOU THEAST
1/4 OF SECTI ON 15
I
:
I
N
89 "55'01"
- - - - - - - - - - - - - - - - - - - -- - - - -1 ) - - - - - - - L - - - - - - - - - - - - - - - -
609 . 70'
'~o
o o
'b
I
I'
- - ----- - - ----- - -
d
-·~·r·
~%
/
·
I'
I
'"
'n
3 I
'n
1 ~
'
S ITE B E NC H MARK
SET S/8" IRON ROD &
CAP TRAV. No/ LS. 3961
EL. ~ 34.06 (NAV0 - 88)
'
'
I
I
I
+
: __
I--
--· ~
01
ro
n
Oo
zw>
0
'
'
' ,..,
- - 15 9"
····~-···
\
··········
-·
'--~·
----
.·.·.·
-
., . ' . ,,
_J
I
. ._- --_- --- -------... - -_---_-- -------------N 59·43· 45" W -
610.49.
-,
I
.--- . . -.-
'·
·
'
' \.____ -.·.·.- · -. ·
..
. ... -- ., ...
'
7 _.:._: ~
'
,!
-
I
·
·
·
·
'
-+
n
w
<(
· . . . ' .. I
N
.' .·'
.
'
N
~
01
~n
w
~I
w3 I
3:
>- 0 ~: I
fz ()'. w~ -~ro
:J .
oo epn
............................. ,.,. ..... .
-·-······· - -···-··
.
'
' -.....
' -....:,
'· .
, , . . .'.'. . . . ,. . . , ... . . . . . . . , ·;._:.·c·:.-_..
.,,.,
. . .. .. ·. . . .
···-·' ' '
"
:·:·:-:-:-:-:-:-:-:-~-:
--···-··
I
I
.
~
'
-
:·:·:·:·~-:·:---:-::: :-~-:-~-:-:-~-:-...
. ______
- · .· ·. ...
-· ·._,,.
··
-...- '·.· · - - - ·"._,
--~·--·---·
~
·
~
WETL ANDS
1.46 ACR E S ±
~
·I'"''
~
.
..
·············
······-·········· ·
~I
·
'~ 11J
·····
- .- .· .·.,.-.,_._,_.
- ~·":"-:--,...,,-'
··.·.·,·
· - · -.·.- ,.---·-·.·.
. - . -.·.-.-,······
i·.-.·.·. ·. ·. -. -,·,·.·-- .· .·.·. . . . ' . . . . . .
·
.
.
..
...
I
r
..
'
. . - .-
. ... . ... ' '/
....
· ·· -
'
.
I~
.
.
.
,... ....... ........ ..-. ...' . '''
'"
I
'
~ -.
'
I
I
~----·. ·
16 12491.5645
A8
447358 ,5 320
161326 1. 7240
015
446566.6400
1612543.5110
A9
44 7 323. 763 0
1613299.05 20
1612538.2265
447326.5399
1613 3 49. 1393
Dl 5·
01 7
446586 .1715
A10
446605.70 30
161 2532.9420
A 1'
44 7309.381 0
16 13376.0320
0 18
446634.8330
1612509.0260
A1 2
447244_1520
1613342.1450
446658.4760
16 12481.7945
A 13
44 7178. 2 390
16 13336.5350
4-46682 . 1190
161 2454.5630
44 7 11 3.5060
16 13348.9510
021
446726.1580
16 12409.1530
44 7052.7470
16 133 85 .6020
16 12350.85 10
447019 4-710
1613352.971 0
022
023
446740.9050
91
446754.2640
1612332.3920
82
4469 53 .5820
16 133 18.96 7 0
D2 4
4 4 6808. 2750
161 22 73.8630
LL
83
8<
85
86
87
4468 74. 6 130
D25
446822.0 780
161 2244.84 70
4-46801.2530
1613333.311 0
1613312.6 850
026
446831 . 5060
1612206.3330
0
446759 5330
16 13307. 2000
027
4 46855.59.30
161219 5'.6 320
446 696.3230
16 133 15. 2340
028
4 46890.0550
16 12 199.2560
446718.8410
16 13374.8090
029
446891.9980
16 121 8 1. 3030
88
446694.6987
16 12 157.9690
446572-22 10
030
0 31
4 46899.9000
8W
1613378. 4076
1613374.. 7470
446903.0540
1612129. 11 10
8 1'
446496.25 50
16 13366.4940
032
4-4 6866.2790
1612121.3330
812
446431. 6131
446388 .6940
1613363.882 1
03 3
4 4685 4 .0350
1612111.7860
4- 4690 1. 1120
1612727.0700
16 13327 .7030
8 14
4 46344 .6230
1613321.6890
815
446333. 9260
16 13320 .5080
446292.2510
16 13322. 5230
817
446256 .6500
E2
E3
446915. 7600
1612664.5200
446922.29 7 0
1612638.50 20
446932. 1889
161259 4.5858
E5
446942.3755
16 12549.36 12
C1
447044_5810
1613354. 2220
16 12651.3090
1612506. 56 10
44 7056.9310
16 12620.5200
E6
E7
446952.01 60
C2
4 4 6972. 90 7 0
16 12491.74-80
C3
44 7051 . 5420
16 12568.2770
E8
446939.3500
161 2413.57-30
C<
4-4 7021.4520
16 125 17. 2950
E10
4-4694 9 . 7 695
1612367. 9490
C5
4470 25 3360
1612466- 1930
1612323.5020
44 7 008.3320
]6 12406.5 4 50
E 1'
E12
4 4698 2.45 00
CB
C7
4 4 6982.2090
161 2276.8860
447030.1610
16 12332. 96 4 0
E13
446982.606 4
1612240. 1958
C8
44 7034-.2640
16 1 2275 . 9 740
E 1'
446982.8230
16 1 2220.1970
CB
447021 3590
16 1226 1. 7260
E15
446971, 4 8 40
16 12186.8320
C10
446994.7 4 10
16 12244-. 7 600
F2
4 4684 7.2250
16 12 7 02. 1400
C11
4-4 703 2.8510
F<
4 46802.2770
446 7 49.1230
16 126 78.0450
44 7075.4850
1612 173 .1990
1612161.5730
F3
C12
16 12520.51 10
C1 7
447107. 8880
16 12423, 2400
F9
44 6769. 23 70
1612503 .3090
16 12502 .2200
1612468.039 0
447099 .0200
16 12568.5070
16 12649. 3410
01
02
4 46 8 45 3690
161 2111 , 3940
4 46 7 99.4230
16 12 156.6260
F 10
F11
F 12
F 13
FH
4 46 786.887 0
C20
C21
03
4-46779_ 77 10
1612 183 .2910
F 15
04
446 736.7 560
16 12224 . 7060
05
06
446706 .3600
16 12251-5630
446689.284-0
16 12265. 2160
w
07
446661 . 4590
· · · · · · · · r-..
08
446602 .7 400
16 12280 .0050
1612246. 001 0
C18
· '
44 7084,5760
=>
(j)
Q_
446791.9250
161 2438.3190
4-4582 4.2920
16 12434. 1680
44 6836 .4570
1612389 .0980
4 4 6855.0930
16 12361.3660
446873.1820
16 12344.8680
446883. 9410
16 12312.8660
F 17
F1 8
446891 . 4070
16 12293.] 7 :;;0
4 4 6846.8010
1612 29 1.0990
F19
4-46830.6560
16 12276.2120
_J
U_
I
>z
1::::i
0
u
m
CfJ
n
><(
[I}
0
z
O:'.
<(
n
2 0
VI
I-
<(
0
L[)
CL z
0
>fz
1-
u
w
VI
:=i
0
u
1612648.!;l6 90
161 25 73. 7370
·
0:::
A14
A1 5
4 46724.6520
·
>w
>
01 9
020
446739.8970
.J""J
..... z
. '
.
' '.' .' .
'.'.'. ,
'
' ' .
..
t::=;[p.. :JJk\IEf-::'
24.8389 ACRES ±
.
....
·
·
·
' '
t
~11
I
SUR VE YOR 'S R E POR T o
N
THI S IS A BOUNDARY SURVEY. THE ABOV E GROUND FI X ED IMP ROV EM EN T S W ER E NOT LOCATE D AS INS T RUC TE D B Y
C LIE N T . NO ATTE MPT WAS MAD E T O INV ES TI GATE THE LOC ATI ON O F UND ERGRO U ND U TILITIE S, FOUNDATI ONS, OR
OTHE R IM PROVEM EN TS, IF A NY EX IS T .
'
_,_
.
THE LEGAL D E SCR IP TI ON
ACT UAL FIELD S U RV EY .
·
S H OWN
HER E ON
IS
A
N EW LY
CREATE D
D E SCR IP TI ON
BAS E D O N THE
R E S U LT S O F
AN
THE UND ERS IGN ED SURVEYOR HAS NOT B EE N PROVID ED A CURR EN T TITLE OP IN ION OR ABST R ACT O F MATTE RS
A FFE C TI N G THE TITLE OR BOUN D ARY O F THE SUBJ E C T PROP ERTY. IT IS POSS IB LE TH AT THE R E AR E D EEDS O F
R ECORD. UNR ECORD ED D EEDS . EAS E M E NT S OR OTHE R INST RUM ENT S TH AT COU L D A FFE C T THE BOUNDAR IES.
' . , . . · ... · I
·· · - . · ·
·· I
THE B EAR INGS S H OWN HE R EON AR E BAS E D ON NOR TH 03"08'40.. EAST A LONG THE EAST R IG HT O F WAY LI N E O F
COUNTY ROAD 389 AS S H OWN A N D R EFE R E N C ED TO G EOD ETI C NORTH BAS ED ON THE FLOR IDA S TATE PLAN E
COORD INATE SYSTE M . NORTH ZON E. NAO 1 983/07. U .S. SU RV EY FEET. DAT UM E S TAB LI S HED US ING FL OR IDA
P ERMAN EN T R EFER E N C E N ETWORK.
<·
1.(1
"'
;{ -··. · - -........
--···--···-··'·' .
.....
-t
N
,,
·,·,·_ .. '.' .. - ·.· ·,·,· ... _,_._
I
446569. 9715
F7
F8
- ..
- - - . ...- - . .. . - . . .
,,
0 14
16 1 2366.3840
-·~rr········~rr-··-·
I'
1613287. 1270
16 12289.6710
......
.
16 124 39.6180
4-47397.98 10
447 11 0.5770
.
:::::<:::.<:::::: ::::: :>::-: ::: .
I
A7
44 7098 .9200
I
· I
·::;-
···-···.
4465 73.3030
C16
·
,-...-r-·--·
·
1612416 .3520
013
1612614.04-09
,n
, ~
446588. 4790
16 13277.0120
16 12650- 0750
.,.,. ...... a
.
'
447426 .5370
0
())
,,,,
'
16 12396 . 3520
44 6716. 5016
, __,._,.. ·. ·. · 1 J""J
-··
.. , .....' 1,',r,· ·...
---...'.'.'.'~·-·_ ·.·.· .. ·.·.·.·.·.·.·.·.·
, , ....... , ,
..
. . . - . .
...
16 12302.7090
446568.4 790
44 674 2.5750
·.·.·.· ..
- · · - · IP
.
'
'.'
446592.404 0
16 13268.9730
010
0 11
0'2
1613297. 1040
F6
·
. - .. . .. . .. ... .... . . . ... . . . . ... . . .. -. . . .. .. .
............. _·_ ·. ·.·.·.· .. · .. ._·- ·.·.· .· _. _._,_.
44 7 482.0 4 40
A6
1613350.2160
F5
.
. ..
"',
E AS TI NG
16 122 77.0 110
1612 192.1 680
.
.
-. -''
' . . -. - ..
.. . .' .
. .
' . . . . . . .
................
1' N
.-
- ·· ,· ,WE1:[k.NOS . ' . -- -. ·,.,. -- ·· .- - ' . ' . - · · -, - , ·
'
... . ' . . . ' . ..
~
..
' '
···'''''········<········~·I
'
..... . . .' '
-. . .-. . ' . ' . .. . .. ..
I'
,
~
··-···-,.,..,.
I
·
NOR THI NG
446609 .0890
09
16 12231.9060
' '
'
' .
'· ·
. . ' ' .
J'.·.- -.·,-,·.·.·.
I , · · · · · · ·
. '
.
I .'.·.-·,·,··.·
1 .
.
__ , __
.
'.
'-
-
447512.7340
FL AG
447 11 7 . 3920
... '
. " . .. . ..
. . .' . '
WETL ANDS
/ 0 .83 ACR E S ±
···-······
A3
A4
E ?S TI NG
16 13424. 4 235
4-4 7098.5150
l'F ! I
'
447528.1404
44 751 8 .5960
C1 4
C15
.
'
0
0 :::'
N OR THI NG
A1
A2
C13
.·.·. I
WETL ANDS
0.8.3 ACR E S ± ,
FL AG
813
II '
<( o_
ll'.
''
·
I
~
36" PINE TRE:E ON
CORN ER
-
·:·:·: ~~··:·:"a ~
~ _19"_,'
m
0
''
,
· · - · ' ' '""· · - · ·
~
'
I'
22," · · ·
' ·.·.-.·.· .· ·
.. '19\
· .,
N
I'
,,
, ·, _
,
· · ~ 31;) · · 21"
. ,,., .
-~· ·
·.·.·. s .·.·.-'.·. ~~: ,
N
~
I
····
I
n
--",t1W! '" IE!,'~ O:E1
.-:- :~:·~: -:-:·:-~:_,_··
-·· 4' ·&'' .
:::~: ~: :7d·.~
·:: -~,: ~ :~,~ : ::
······
,·
\
I :-'
', w
n
· "· - ·· ,4., . 'i:J, -
>t>~?,
:
I
-
-··· n 19· ··"·
· ' . ' .,;... 'I
~'~
I
------<>-- ----------- ------------------------------
658. 29 '
0
O:'.
z
z
>_J
WETLAND FLAG TAB L E
I
w-
<(
I
'
f- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
I
~
0 2
c
'""' '"'"
I'
:
"'"1
z
w
>
<(
THE M IN IMUM H OR IZ ONTA L A CC URACY FOR THI S SUBU R BAN SURVEY, PR EP AR ED IN ACCO RDANC E WITH THE
S TANDAR D S O F P RACTI C E S ET FORTH B Y THE BOA RD O F PRO FE SSIONAL SURVEYORS AND MAPP ERS IN C H APTE R
5J - 17.050 - .05 2 ' O F THE FLORIDA AD M IN IS T RATI ON COD E. IS ON E PAR T IN 7 , 500. THE MAP AND M EASUR E M EN T
M ETH ODS U S ED FOR THI S SURVEY M EET OR EXC EED THI S R E QU IR E M EN T . THE D IM ENS IONS S H OWN HER E ON AR E
IN FEET AND D EC IMALS THE R EO F .
A R EV IEW O F THE FLOOD INS URANC E RATE MAP FOR BAY COUNTY , FLOR ID A, MAP N 0.12005C0.332 H ,
JU N E 2, 2009 IND ICATE S THAT THE P ARC EL S H OWN HE R EO N IS W ITHI N ZON E X AND A.
R EV IS ED
···············
j
··~·:·.·~-:-:-.-::
. -.-.·._·:.
- -- --- --- -- --- - - --. I--- -- -- - --- -- - --- -- -- -- -- -- -- -- - ------ ---
111
N
'
1
N
r
89 "24'23"
612.11 ~
W -
THE FLOOD ZON E LI N E D EP IC TE D HER E ON WAS SCALE D
NOT CON T OUR ED OR BAS E D ON GROUND V ER IFI CATI ON.
- - ------ - - - - - -----
F ROM THE
FEAT UR ES
SET 5/8~ IRON ROD &
CAP TRAV. No/ LS. 396 1
EL.= 35.05 (NAV0 - 88)
S H OWN
BY SYMBO L AS
THE FORMATTE D C E RTIFI CATI ON
BAY W E ST D EV ELOP ERS
-
IS
IND ICATE D
IN THE
LE G E ND A R E NOT TO
.,
1XJ
I
WETL ANDS
··
0.1 1 ACR E S ± --... · ·
±
P.O.C.
P.O.B.
P.C.
P. T .
P.R .C.
P.C .C .
N
E
, ·1
'I
s
w
N
'
'
' '
30.7"
0
~,
·I
32. 2 '
PG _
DENOTES SET. 4"x 4"
CONC. MON. No. LS. 3691
''
I
c
\.
,.
6
'
\
r -------~,/
'
I
I
I
I
''
..
----,~:-N- 8 ; : ; 4--.o-,~,-w--~:-654-:o-s-.---,--- -
" ' - - DEN6 TES SHED EAV E OVERHAN G
I
I
:
I
I
''
I
~6 0 !
E_ 4 0 th PL "-.! A
'
I'
'
I'
I
'
'd
"
_l
-----~ - ---- ·
II
:
I
I
1
I
I
I
I
I
1
I
I
1
'
I
I
i
2 1)1 ! E. 40th PLAZ A
1
26 15 E _
·l-Oth '°LA~A
!
L6?.5 E
o!-Uth PLALA
WAS
I
I
'
'
I
'
'
'
'
I'
I
I'
SCALE.
ABBREVIATI ON S
MOR E OR LE SS
D E GR EE S
M IN U TE S OR FEET
S E CONDS OR INC HES
PO INT O F COMM E NC EM E NT
PO INT O F 8 E G INN ING
PO INT O F CURVAT UR E
PO INT O F TANG ENCY
PO INT O F R EV ERS E C URVAT UR E
PO INT O F COM POUN D CURVAT UR E
NORTH
EAS T
SOUTH
W ES T
S E CTI ON
T OWNS HI P
RANG E OR RAD IUS
O FFI C IA L R E CORDS BOOK
P RO FE SS IONA L LAND SURV EYOR
PAG E
FD.
COR.
No_
CONC.
MON.
R . O .W.
S . R.
C.R.
B L DG.
EL
"CH
L
OH
'-LB
LS
F .8 .
EF B
F _F _
21"'
FOUND
CORN ER
NUMB ER
CONCR ETE
MONUM EN T
R IG HT O F WAY
S TATE ROAD
COUNTY ROA D
BU ILD ING
ELEVATI ON
D ELTA/C EN T RA L ANG LE
ARC LE NG TH
C H ORD
OVER HEAD UTILITIES
C EN TE R LI N E
LI C ENS ED BUS IN E SS
LI C ENS ED S URVEYOR
FIELD BOOK
ELE CT RON IC FIELD BOO K
FI N IS HED FLOOR
T R EE D IAM ETER
0
r.
C2
UJ
UJ
r.
0
r.
UJ
CYPR E SS T R EE
------- - - - - - _-,il
/
DENOTES FD. 4· x 4"
CERTI F ICATE
CONC. MON. No. LB 2372
N 446211.0154 E
1513351.7025
I HER EBY C ER TI FY THE SURVEY HER E ON TO B E T RU E AND CORR E CT T O
THE B E S T O F MY KNOW LE DG E AND B ELIEF AS O F THE DATE SURVEY E D.
\\I
41
:
'
I
S EC.
T
R
O.R.8.
P. L .S.
..--
0
-- - -- - - - ------ - - - -- - -
MAPS AND
FO R :
SYMBOLS &
-_'O:'.'ll ·t.r1E1 ~ Clf:I
Jfil3. 1~-·-., 00 ,!Gt ·,(!
INSURANC E R ATE
THE SURVEY MAP (S) AND R EPORT AR E NOT VA LI D W ITH OU T THE S IGN AT UR E AN D OR IG INA L RA IS ED S EA L O F THE
FLOR IDA LI C ENS ED SURVEYOR AND MAPP E R WH O PR EPAR E D IT. ADD ITI ONS OR D ELETI O N S TO SURVEY MAP(S) OR
R EPO RT B Y OTHE R TH AN THE S IGN ING P ARTY IS P RO HI B ITE D WITH OU T WR ITTE N CONS EN T O F THE S IGN ING PARTY .
S ITE B ENC H MARK
I
FEMA FLOOD
,'
:'
I
JOB No .
12 300
1 2 - 20 - 2016
DATE
O F SURVEY
S K IP P ER C . RU THE R FORD, P . L .S.
PRO FESS ION A L SU RV EYOR & "'1AP P ER
FLOR IDA LI C ENS E No. LS 3961
FILE No.
R 12461
12 - 27 - 20 16 A D D E D T R EE S
z
w
>
<(
NOTE.
C LOS EST flf"E H 'n:IF1 ft ~~ T F CTL,"'ID
E~·iTtl'°'"-J.:E
I
HW'r'
I'
~T
THE
TlJ rAQ\1\1;\T HICHLl".~ID.£ "''IC
)89
I
..
I
I
'
I'
I
31
I
'tl
-r
I
r--------------------------------- - -------------------------------------------- +-~~~~~-
I , .'"'
'
'
~
i
' \
I
I~
1/4 OF SECTI ON 15
I
o ,~
cc- ,, "
'
I
\
\\
I
I
I
j
1
I
1!
!
I
'
11
r
u
r
II
I
'
I'
:
11
CJ>
O'.J
"l 0
,:
I
I
i
I
w
·>
0 <".
z Q_
~
\ ,\
:~
:r:
<{ ,,.
'1
(<"j \
I 'I 1--,/
......__-
I
I
,_,,
I
f- ·
I
~
u
'
'+!
I
'
i i
zg
~1
'6.
'lo
i i
)-. 0::
\
·,.
Ii - //"-._ \ ----
,1':
I
0
0 "'.
0:: 0
\\\
,
I
~ !
APPROX IMA TE LOCA TI ON OF
OVERH EAD U TILITIE S LI NES
)
~
I
1
'
\...
I
\
\\
o:~>>
dd
I
~~
I
\ii . .
I
~zm
I
I
~
" '
WETLANDS
\
\
/
......
' 1·-..
A
;;,.._ -
'°"
(/> .
29. 94
\
~
WETL ANDS
_ \_
\
'
- ..
\
\
'-
-
-
\
-
~'\
.__ -
"
")
\
\\
I')/
/
t
I
II
II
~
I
I
I
I'
0
'
I
I
I
S CT 5~" 1 R~ROO&
I
I
CAP TRAV. No/ LS. 3961
EL= 35 05 (NAV0 - 88)
1
~- --------------------------------------------.. ------------------------i-----_
I
""
I
I
II
I
''
I
I
:I
W
'
z
I
i
I
I
i
I
-\
.
:Jm
i~
\
c <
I
·
I
of?
I
~~
I
:s
I
I
()]
''
,..,
I'
I
N
I
i'
z
)-.
I
I
0::
2
iI
<{
u
J
'
l
I
I
I
I
I'
'
I'
I
II
Ol
''
'
I'
'
I'
'
I
I
FD .
CO R.
No
CON C .
M ON .
R .O .W .
S.R .
C .R.
B LDG .
EL.
6
L
CH
OH
LB
LS
F.8 .
EFB
F . F.
FOUND
COR N ER
N U MB ER
CO N CR ETE
MO NUM EN T
RIG HT O F WAY
STATE ROAD
COUN TY ROAD
B U ILD ING
ELEVATI ON
DELTA/C EN T RA L A N GLE
A RC LE NGTH
C HO RD
OV E RHEAD UTILITIES
C EN TE R LI N E
LI C ENS ED BUS IN ESS
LI C EN S ED SURVEYOR
FIELD B OO K
ELE CT RON IC FIELD BOOK
FI N IS HE D FLOO R
0
r.
i'2
I'
'
I
I
UJ
UJ
I
I
r.
'I
I
I
I
'
I
I
MORE OR LE SS
D EGR EES
M IN UTE S OR FEET
S ECONDS OR IN C HES
P O INT O F COM M ENC EM E NT
P O INT O F B EG IN N IN G
P O INT O F CURVAT UR E
PO INT O F TA NG ENC Y
PO INT O F R EV ERS E CURVAT U R E
P O INT O F COMPOU N D CURVAT UR E
N OR TH
EAST
SOU TH
W EST
S ECTI ON
T OWN S HI P
RANG E OR RA D IUS
O FFI C IA L R ECOR DS BOO K
PRO FE SS IO NAL LAN D SURVEYOR
P AG E
I'
I
0
N
PG.
ABBR E VIATI ONS
I
I
"
R
O .R. 8 .
P. L .S .
I'
I
I
' ,,
T
I
''
I'
I
S EC .
I
I
'
P.O.C.
P .O .B.
P. C .
P. T .
P. R.C .
P.C.C.
N
E
s
w
t-
i
I
I
(!)
+
I
I
I
N
±
c_
I'
N
SYMBO LS &
I
I'
I'
I
L __
'
I'
I
I
'
-,'
I'
'
'
I
I
I
I'
0
I
I
0::
u
N
>
·
I
::::J
I'
I'
0
I
'
,,.
Jo
I
I
I
0
I
I
I
()]
()]
I
Uz
w
(!)
I'
1--
CJ
I'
I
'
u
I
z
I'
I'
>f-z
I
I'
/
0
1-
I
'
\
CL z
1
I
I
L[)
I
:
I
0
'
I'
J
/
<(
I'
I
I
v
(!)
I-
I'
I
I
I
n
0
I'
I
I
I'
'--..
D::
I
I
I
I'
z
I
''
I
'·
0
1
-,I
"' I''
,
rn
I
I
I
·
n
1-
I
I
JEVELOPERS
,.,
'I'
I
'
l"IE~T
CTl
>OJ <(
u
THE F ORMA TTE D C ER TIFI CA TI ON IS FOR:
B,ll. \
u
I
I
I
I
~--.
I
=i
0
I
I
,_
S ITE B ENC H MARK
>z
1-
I
I
I
FE A T UR E S S H OWN BY SYMBO L AS IND ICA TE D IN THE LE GE ND AR E
NO T T O SCA LE .
i
I
I
I
I
I
I
I
'
'I
'
I
'
I'
N
ii'
I'
I
I
I
I
I
I
I
I
THE SURVE Y MAP(S) ANO R EPOR T AR E NO T VA LI D WITH OU T THE
S IGNA T UR E AND OR IG INA L RA IS ED S E A L O F THE FLOR IDA LI C ENS ED
SURVEYOR AND MAPP E R WH O PR EPAR E D IT, ADD ITI ONS OR
D ELETI ONS T O SURVE Y MAP(S) OR R E POR T BY O THE R TH AN THE
S IGN ING PAR TY IS PRO HI B ITE D WITH OU T WR ITTE N CONS EN T O F THE
S IGN ING PAR T Y .
I
I
I
DJ
I
· -~
I'
<']
l.- -
I
_J
LL
'
I
_..... .,
THI S IS A TOPOGRAP HI C SURVE Y, F OR IN F ORMA TI ON ON BOUNDARY,
WETLANDS, AND FL OOD ZON E S S EE FILE No. R1 2461 DA TE D
7 - 20 - 16.
I
,
I
I
I
I
I
'
I
i
''
I
I
I
I
I
\
SURVEYOR 'S REPORT:
01
I
10
I
~
I
I
2
I
I
I
I
I
~
az
I
'
'I'
{
I
I'
I
'I
I
I
i
'
/
I
~If
!
I
1
<(
\
''
'
I
'''
r
)
..
:
0
I
I
J
'
I'
'\ / V
I
I
I
PUB LI S HE D ELE VA TI ON O F 32.44 NAVO 88 DA T UM .
/
I
: -A--
I
/
i
)-
I
I
\
o_
/
i
i
( ' __ /
\
I
/
\
\
j
I
t·
\ II
',.
II
VE R TI CA L IN F ORMA TI ON S H OWN HE R EON IS R EFE R E NC ED TO THE
NA TI ONA L GEOD ETI C SURVEY, B ENC H MARK No. W 290, HAVING A
i
·~
\\
I
0
,
;d ·I i/-
--..
I I
I
\
\
--~
I
I
\
<>
'
~ .;I
...;~
I
'tl
\\..
\
II'
I
I
i
\
I
'
\
I
\ \ :I
I
~
LL
I'
(
\
\
\
\f:
1
II
1
I
,..-----,.J \
-- -t~~., -~,\) [~
\
I
~1
~
~':
..:<><
11)0
----
!
~~-__}\ ! -
'\
\
I
I/
"'''\.
(/)
I
' '----\
\
~'\'---'\-----~ '
~
~ 1 I1
:
<>\
I
I
11 11
,4
-1,
\
.
I
I'
I
\ ---
""l(;'.:_1~-" E 1 f 'l ,3E1
"'\
~I
-------
O::'
=i
I'
""'
' \.
'
I
I
I
·;;:;;;:;
'2
___
I
I'
''--- ~/'\ !
' .., -:
I'
I
I
\
~---
~\\
~,.,
_
I
~~,-'"- i~.cEL_~~c. W. INV.
a
\
(
I
I
I
~
\' \ '(,
' "
\
\
\\
I /Ii
I
01
:::J
0
!
":
;!.2 -~-.
,, ~
\
\
/--
,
>w
>
: ,------------------------------------------------,
a
z
<
' "''
~
...
~
S ITE BENC H MARK SET
5/8" IRON ROD 8f CAP
TRAV. No/ LS. 3961
,1'1
I
(
0
~
I /rI
1
I
I
I
a
t'll~
\.\,
0
0::
z
z
>_J
",
/ -- ,;. . --
/
<(
I
,/ -2=1
.,1 I--------------------------------------
-----+; -
'%\%_
NOR TH LI NE OF THE SOUTHEAS T \ \
0
I
I
I
-- ~ --
I - :
II
II
, .. R.C.e.
N. INV. EL . ~ 31.60
0
'~
/'
.f
\
/
I ~
'
"-
'
'
I
il~
!IE·
''5~1
(
I'
'I
I
CONC. 1
~
!~~=I . PACE
0
I
I
I
'
i
~'i':;:i/4.SC: I .-"
0R":O
"
,.
0
fii
0
ID
''
I'
I
I'
CE RTIFI CATE
I HER EBY C ERTI FY THE SURV EY HE R EON T O B E T RU E A N D CORR ECT TO
THE B ES T O F MY K NOW LEDGE A ND B ELIEF AS O F THE DATE SURV EY ED.
I
I
'
J OB No.
I'
I
I
9 - 26 - 20 16·
I
DATE O F SURVEY
I'
12300
S K IPP ER C. RU THE R FORD , P . L .S.
PRO FE SS ION A L S U RV EYOR & MAPP ER
FLOR ID A LI C EN S E No . LS .3961
FILE No.
R 12 4 6 1-TOP O
FOR SCALE VERIFICATION AFTER DUP LI CATION, THI S LI NE SHOU LD BE 1" LONG
SITE DATA SCHEDULE
I REQU IRED
PARKING SPAC ES
---- ---
N/A
I
PROVIDED
I
N/A
I
SF
LANO USE: LOR (LOW OENS rTY RES)
ACR ES
AREA
TOTAL S ITE AR EA
WET LANDS
24.84 ±
3.2 17 ±
1,082,061 ±
140, 138±
S F/TOTAL AREA
TOTAL
IMPERV IOUS SPAC E RATI O
IMP SPAC E: 466,349 SF
ISR = 43%
OPEN SPAC E: 450.938 SF
OP EN SPAC E RATI O
OSR = 41.7%
SOIL TYP ES I SEE GEOTECHNICAL SOIL BORING & P ERC. TEST REPORT
I P ER LYNN HAVEN LAND DEVELOPM ENT COD E
LANDSCAP E BU FFE RS
BU ILDING S ETBACKS
I PER LYNN HAVEN LAND DEVELOP MENT COD E
- - - -- -
LOT REQUIREMENTS
NUMB ER OF ALLOWAB LE LOTS 4.9 UN ITS PER ACR E = 121
NUMB ER OF LOTS PROPOS ED
86
STREET NAMES:
CASON DR IVE
CALEI GH CIRC LE
DRAWING NOTES
10
10
1.
ON LY ABOVE GROUND FEATUR ES AR E SHOWN ON THI S SHEET. RECORD ED PLAT SHALL
DICTATE THE EXACT LI MITS OF EAS EMENTS.
ALL STRIPING ON SITE SHALL BE THERMOPLASTI C & SHALL BE PER FOOT STANDARDS.
SEE LEGEND, SYMBOLS, SECTI ONS, DETAILS & SP ECS ASSOC IATED WITH THESE PLANS.
BEARINGS & DISTANC ES SHOWN ON THI S SHEET AR E FOR ILLUSTRATIVE PURPOS ES ON LY.
THE FINAL RECORDED PLAT SHALL DICTATE THE EXACT LI MITS OF LOTS & RIGHT- OF- WAY.
EAS EMENTS SHOWN ON THI S DRAWING AR E FOR ILLUSTRATI VE PURPOSES ON LY. THE FI NAL
RECORD ED PLAT SHALL DICTATE THE EXACT LI MITS OF EAS EMENTS.
PROVIDE CURB RAMPS FOR SIDEWALK AT CONNECTI ON TO ROADWAY PER FOOT IND EX #304.
OBSTRUCTI ONS NOT ALLOWED WITHI N EAS EMENTS { I.E. FENC ES, TREES, SHRUBS, ETC.)
PLAC E DOUB LE 16" OR SINGLE RO LL 30" STRIP OF SOD AT EDGE OF DR IVE.
2.
3.
4.
I'
10
S ITE B ENC H MARK
S ET 5/8" IRON ROD &
CAP TRAV. No/ LS. 3961
EL. = 34.06 (NAVD - 88)
5.
6.
7.
8.
SYMBOL LEGEND
IWI
PROPOSED DRAINAG E INLET
~ PROPOS ED FI RE HYDRANT
OJ
CJ)
n
Cl)
t')
n
Oo
0
<(
<( Q_
0
PROPOSED MITERED END SECTI ON
....
PROPOSED VA LVE
IEJ)
PROPOSED WATER METER
'-1--PROPOS ED CONTOUR
-
>
PROPOSED MAN HOLE
~- - EXISTI NG CON TOUR
n
z w
~
[Q)
HA- "X" GEOTEC HAND AUG ER LOCATI ON
01
n
STORMWATER BASIN No. 1
I
I
)
>- .
z O'.
O'. "'
f- 0
I
hNc_
I
::J ·
S DEWALK
I
I
I
00
uS
MOD_TYPE E CURB\
l-
-I
I
I
EDGE OF
(DWS}
- .,:-
PAVEMENT 1~· .~
25' DOUBLE YELLOW STR PING
PER FOOT INDEX 17346
I
_ _ _ _ _ _ _ _ _j
I
WHITE LETIER NG "STOP"
~
PER FOOT NDEX 17346 ~
I
I
I
I
OJ
12" WH ITE STRIPE
PER FOOT INDEX 17346
--..
~
.
. .
24" WHITE STOP BAR
PER FOOT INDEX 17346
N
---.._ .._J' -.ffl--ll'--6' WIDE CROSSWALK
.
4
4·
. . . . .... ' .
.
. . . . - ...... ..... ..... .
. .....- .... .............·~--
. . ..
. .. .... .. . ....- .-.. ......... .. . .
.. ... ... ...-.....
. . . ... . . .
. ... -. ...... .. ... ' . .' . . ' .. ..
.. ·.·
.· .... ·.·.-.· .·.·, ·.·
- . .. .. . . .. . .. ... ..' . . . .. . . . . .
.
. . . . . . .. . . ... . '
'
·
·
·
f
·
·
·
·
·
·
·
·
I
I
I
..
. . . . . .. . . .
STOP ·.
"\-1
- ----1
I
I
·
~·
"
m
'
·····-···
-···· ···-.
.....
· . ·.·.·.·-·~. ~ ·.·.·,·.·.· ..
. - . . . . .. . . . ' . . .
. ·.·.·.·.·,· .. . ·.·.·.·.·.·.·.·.
·· .·. ··
·· .· .··
. . · · ······
. . .
/_;,..-.;.
. . ......
- . .. .. .. . ·....
. . '.....
. . .. . ·.·.·. . . ...
..
.. ·.·.·.· .· ·.·.·.-.·-·.·. · ..
I
I
'-------
~
\
INTERSECTI ON LAYOUT
I
SCALE 1" 20'
~---~ ---~
.
I
I
-- -- --- ---
I
-------_ti
NOTES:
1. INSTALL DETECTAB LE WARN ING STRIPS (DWS), AT ALL PEDESTRIAN CROSSWALKS, ON
ROADWAYS, NOT SING LE FAMILY RESIDENTI AL DRIVES. {P ER FOOT INDEXS 304)
2. USE STANDARD CROSSWALK AT STOP LOCATI ON AND SP ECIAL EMP HAS IS CROSSWALK
AT ALL OTHER LOCATI ONS (PER FOOT IND EX 17346) .
3. (DWS) CO LOR TO BE YELLOW.
4. (DWS) TO BE CAS T-I N - PLAC E REPLACEAB LE STYLE AS MANU FACTURED BE ADA
I
5.
OJ
S ITE B ENC H MARK
~
S ET 5/8 " IRON ROD &
CAP TRAV. No/ LS. .3961
EL. = 35.05 (NAVD - 88)
··
SO LUTI ON, INC. (www.adatile.com) UN LE SS OTHERWISE APPROVED BY CITY.
CROSSWALK MINIMUM WIDTH S: INTERSECTI ON CROSSWALK 6'. MIOB LOCK CROSSWALK
10'.
L ____ _
5' CONC _I
S DEWALlf
01
VARIES (SEE PLANS)
~
7'
rsETBACK
-
I
0
0
N
0 .7 '
32.2'
l
25·
"'
DENOTES FD. 4"x 4"
CONC. MON. No. LB 2372
N 446211 .0154 E
1613351.7025
- - - -DENOTES
- - -SET.
-,-4"x 4 ·
CONG . MON . No. L''f- .3691
I
I
I
I
~~
2 63 7 E . 40th P L AZA
2601
E . 40\h PLAZA
0
<10th P LA Z A
\_
40th PLAZA
-
7'
SETBACK
Ql
.!:::
'
:
(/)
z
7_5·
I
I
I
::5
/
()._
LOT SETBACKS REQUIRED
B' UTILrTY ----!
EASEMENT
FRON T (25 FT MAX IMUM)
SIDES (10 FT SIDES @ CORN ER LOTS)
REAR
LANDSCAPE BUFFERS
I
I
PER LYNN HAVEN LAND DEVELOPM ENT CODE
I'
I
DETAIL - TYPICAL LOT LAYOUT
I
N_T_S _
I
I
I
I·
'
w
1'
· 1!
1--
I
I
(/)
_J
_J
'
!
-
I
REV
DATE
BY
REVISIONS
J HS
ISSU E DATE: MAY 2017
. __ _1--_ _ _ _ _+-_ _+-_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _..__ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ ___,,
NOT
R ELEAS ED FOR CONSTRUC TI ON
BY:
··PANHANDLE
OVERALL SITE PLAN
ENGl~ERING,INC.
ANDREWSPLAN~TIONSUBDIVISION
SCALE · AS NOTED
D ES IGN ED BY:
~ O---l------+---+------------------------------------------------------11
~
261 1 E
QJ
4
20 FT
7 FT
25 FT
2615 E.
~ ~~~~~~~~~~~~~~~R-~:::-=-·~~ ~~~~
~
N
lO
..
C2w
"'"""~
>
0
·
I
z
::5
()._
w
f-
r/)
_J
. . .~....~~~~--~....~~~~~~~~~~~~~~~~~~~~~. .~~~~~~~~~~~~~~~~.-~~~~~~~~~~~~~~~~~~~. .~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~--..-~~~~~~~~~~~~~~~.-~~~~~~~~~~..... _J
a:i
fa'
I
I
I
~
· 20' MIN_
c
j--
4
l 11 .
.
. ·
. I I
Ii.- MAX
L
\
.
33'MIN_
VARIES
(SEE PLANS)
-------1
SElBACK\
oo·
SETBACK
I
I
-
1 . ,____
'
I
I
I
w
24·
ROADWAY
-t
10"
DATE :
ACAO FILE NAM E:
57916 - Be1.dwg
·
·
·
ENVIRONMENTALENGINEERS ·
CM L ENGINEERS ·
LANDPLANNERS
3-~u~Hi gh- n ~nnH-n . ~rid· 3(850)763-5200
Fax(850)769-0730
pe@panhandleengineering.com
~==~~::,,.",',';>;:;,
CM"'P""
e '~'"'"'· e C """
s teptien E. Price, PE_ 71646
-c--··'~
1
579168
DPR CERTIFI CATI ON # EB - 7806
C2
W
>
~
PROJ ECT NUMBER
LYNNHAVENFLORIDA
1
SHEET NUMBER
-
JJ
r0
1--
""'. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . L!)
@PANHANDLE ENGINEERING, INC. ALL RtGHTS RESERVED_ NO PART OF THIS DOCUMENT MAY BE REPRODUCED OR UTILIZED IN /WV FORM WITHOUT PRIOR WRFTTEN AlJll-10RIZATION OF PANHANDLE ENGINEERING, INC
FOR SCALE VERIFICATION AFTER DUP LI CATION, THIS LI NE SHOU LD BE 1" LONG
'
0
I
I ~
I 'I
I
~-
I
r
L
8,
I
I
I
I @
1~
H A~
\2!lJ
I
I
f:ll-1.-
. ,,
'
\
'
1, 'b
I·. .
I '
'
:l:r:J
:r
STORMWATER BASIN No. 1
"'
0
:4---
'~
00
f
r
@)
I
II
I
(")
Cl'.
()
.
.,
.
'1
11111111111
11111111111
11111111111
111111 11111
11111111111
11 1111111
111111 11111
,i
~ HA- 10
I ·
I
"'--HA- 9
'
!O
'P
,+
:!;',,....
,j
;
~
I'
"'
I' ''
'=----- -
,,"
--
@
t
I
I
I
HA- 11
N 446850.8399
~4Jl 612256.0692
LAT.Jr N30" 13' 26·
LONG. W85" 37 ' 4 1·
I
I
I
r
I
I
I '
I
I',,
i
I
1'
I
"
I
I
I
I
I
I_
~ I1 I1
""
J
'\.IA-6
I
N
~
QJ
QJ
.!::
(f)
_J
<>::
Cl:'.
w
<>::
I
l-
@
HA-B J
@
}>@
HA- 7._/
s
z
::sCL
w
1(f)
FOR SCALE VERIFICATION AFTER DUP LI CATION, THIS LI NE S HOU LD BE 1· LONG
.
_.. --__..;·:...:=--=
/_.,.-
/~
·--------.- ------=
==-= ===-= =::::: = ==-----: : -----------·
-: :._"""'
....... '...',,
"\\
//
/:::=tr------------.::
,
'\
;! / / / -- -- - ---------~, '... )..,:; :·
fl
'tt------------------
/I I,-=
--
-
--~, .·>"<\
-
~
11
------------------------ -·-----------
11 Ii I l(l1rr= ============ ~illl I: I ii
I
I
I
I
I
I
I
I
I
III
III
III
1j I
III
III
III
I
] 1
11111
11 11 1
1111 1
111 11
111 11
111 11
1111 1
11 11 1 I I I
1111 1 I I I
11111 I I I
11111 I I I
11 111 I I I
111 11 I I I
11111 I 1I
STORMWATERBASINNo. 2
11
11
11
11
II
II
11
I 1111~
,JJJJ)I J I 11
\\> 0'2:=:=:=:=:=:=:=:=:=:=:=:=§/. 1/ I Ii
1
\ ȣ'.- - - ---------~ ~ I
----------- - -- - - ~\ _/
....:.-
, ....._
__
__ - - - - -
------
-\'(
----1
//
d·'
I
, ..
' A
'
L v~- -_J I .
.!
---------------,-.
.
1---- I : :
' __®
I
L
=-__ _J :
I
I :'
I
,
,
I
·1
/,
1
I I.
'
i
'
I
/
---------
,
lf>J
I
I I
'
,
:
Q
:
-
Ii ·. I
1/
;I :
/
.
-
/'\
1
\',//
////
/
/
/
1
_\
~
-
-
.
_.
I
-
-
-
-
.
... -
,
--,
.
-
..
c~r==
.'
I
. I :
.I I
:
I
.L
I
,I
:
I
I
I
!
I
I
ll
I
_J -
L
-
.~
.
... "
-
'
.
-
-
-
-
·· .. , .. .
-
-
-
.
-
-
.
I
I
- ,
.
.
- - - - - - - r------T - - - - - - , - - - - - - - , - - - - - - T - - - - -
I
I
I
. ". .
co
I
I
®
I
R I',1
Ill
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
~
I
I
I
,I
I
,I,
I
I
I,
I
I
I
I
I
I
I
I
I
I
I
(N\
I
I
I,
I
I,
I·
)
-
I
I
I
I
I
-
I
I
I
I
I
--
.. --------1-.. ---
' ,., 1,,,
I
I
I
I
I
1 ::._____c~~ ~--- .: . - - . .L- - - : : -:--:- =-1 __.- ..-.. ---::--:- -:-1._ ______
·····
I
J__ _ __ _ _
I
I
I
I
I
I
I
I
I
I
+~-- ,
I
I
I
I
I
I
I
I
I
-
I.
I·
I .
---~--:~·
I
I
I
I
I
I
I
I
I .
I I:
I I.
I -
I- -I 1--I 1--I 1·1i1·1!1--I 1·-1 11 1--I 1--I 1-1i1-1i1-l ,
i_~J' l@_J' !_ @_J' l_@)_J le§l_J LCID_i' i_~ J' l ~J' L@)J' i_ ®-i' i_~J !_~ J I~ J:
.·" .~: .
· ·:.~
I
I
I
_J _
-- --
I
®
i
i
I
I
!
!
- - -- -
I
I
I
_J
-- -
-
-
-
-
-
-
- -
I
I
I
I
_J _
)
'
'
-- ---------
-
..
.
"
I
- 1'11
I
I
I
I
I
i'
-
.-
.. -~ --- ----L---- -- ~------~------ - L- -----~- -----~-- -----L- -----~---- --~------- L------~-- ------_ L
_
I
__
I
L _
- L
- - - _.kJ _I_ - - - - -
_J
--- -
-~-
I
I
I
I
I
····":· ·· , . · .. ·.'-'-,
- -------
·~
- . ' ·.
-
.
:
\!:-/
:1 @ :1 @ 1:1 CF-') !:I @ I 1@ 1:i ® 1:1 © 1:1 R , : ,
L
. __J·:·L __ _J·: L __ _J·:L· J';
. _J·:L· _j'iL _J·:L· _J: L __ _J·:·L __J :·L __ _J·:·L __ _J·:·L __J, L
_ __ _--i
~---- ~------~-- -----L _____ _
"~
. . : . . : . · :.
--
I
I
I
,,1,,.,,,, ,,..
I
.
;
1:-~
:
1®
~,
1
:
1
l
:
r~1
:
r-1
:
r-1
:
1-1
:
1
-1
:
r-1
:
r
l
:
r-1
:
r-1
:
r-1
®
~ ,I ®
I
I
L __ _J : L _J
I
,
1
@:
I!
!
-
.:
~
--- ---,------ - r ------ T------,-- -----,-- ----T---- -- ,
i :I
I I
I I
I
@ ::: @ : : ® ::: ® :
--~ : L_ =:_J I l_l __ ,;_j : ~- ~
..-·'
...
1 -
:. II~--1.!
:.: I
-.
I
----"--,~- --L_ _
I
1
.
,_
. ..
... ..
I
~
GI I8
I 8 1
l ;' : L __J: /___ _J: /__ _J: I
,'
C\
/
---------
___
I
/
/
-----L
- - - !;:;'t--111
·
-
@ :1
I
_,_ ., __ ·: :: ·.:c: .a
:
/
I /
-
I
I
I
I
I
\,
-
·>-.·
@:
I__ _J
I \ ··
\
-
,-
I
I
i.
-
··
-
I
I
.
i
- - - - - - - - - - -
1,'
I
'I
: 8 :
L ____ _J
®~
-
' L_
:
.i. p
.
=-
I 1-.-
I
'
L __ _J
:.· 1
1·----1 : I:
,8
·· I
L-~-- _J
a --------------T- :
1----1 /
I
-
1-:-i I ':l ! 1---1
I I.
1;
;
I
I
II
I
'
(
~·- ~c r ·.c. : c:·. :·...
1
··
-
.
: ;:
I
. _ : -·"· ·
III
L~
__
_J : .
-- - - - - - ------,- .
I '
.
1----1
';
-
~----T------1-------r------
'1'1' .· I
' 'I
I Ji
·-
-
-
I
ij .~
----- L~ ~_J--1 1' :
I..
~ ~··
4
I Ii .
I ii "'
iJ ;
I Ji ,.
1 ----1~~-=~ =-i--:-1
·
'
Ii '
I
I I! .
I !/ I i1 ,
'
I
'i i
'
~
I:
I'
·· 1
-
-' ,j
¥
: I :
I
i !
i
! i
I
I
I
I
I
I
I
I
I
I
I
I
_TM _-.J.
· .._
TM
I ,.....w_ "."
1
~
:
,I
I
I
I
I I
·
-
w
·
-
,
LJ .
I
---e,.-I
I
I
I
PARK
-
I
I
I
I
I
I
. . :::;..---
- - - - - - - - ; -,
V'~~ - - - -- - ,,-
, ·v _ ~
=== ==
~------::- ---
- _ ~_____.___..
-
, I. ;1 //. '
=-
J-:.>"' _J
-~ :~
~--- ;- ~ '~.
= ===-=-=-~
=:::1--z--,
___.-:, . . . . \ '
~-- ~
0 :,,·::-::.==
== :;=
===== =
11 ·"/'///;.:_.,...
- - - ____
., _________
--- -
-- ----- -- --
..
'\_\
11
1
(Ii ~ ~ (fr;~F ~~ ~ ~ ~ ~~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~~ ~~~~ 1~ 1~~ 11
I
I
I
I
I
I
11111 1111
I I I I I 11111
1111 1
I I I I I1_ 1111
-'- · -·-~J
1.1
1 ..
I
I
l 's ToRMwATER BAsiN-No" ff
I
i
I
I
'
I
I:::J
~
I-
0
_J
1-- z
I
0
11111 I I I I 11
111 11 I I I I I I
1,_,_ "_ '
-----------------1UILL II
I
(J)
I
>
I
0
Cll
:::J
~
(/)
~
~ l:;~::~::~:;:~::::::::;::;;:;::::::::=:=:=::::::::::_~-=::::::::::::=J~~~~S
REV
DATE
BY
REVISIONS
DESIGNED~CA~BY·
L~E·~JHA~SStN~OT~E~D: : : : : : : : : : : : : : : : : : ~ .::PANHANDLE
2~· _ lt~~~t~~~~~~~1~~~1~~~~~~~~~~~~~~~~~~~=====~~~~~~~~~~~~~~~J[~~:~
D
~
R
A
~
W
~
N
~
B
Y
~
·~
j
~
d
m
~
;
;;~~~~~~~~~~~~~
l: : : =±: : : : : : : : : ~: : : : : : ~: : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : ~ : : : : : : : : : : : : : : : =J~REV~l~EW~E~D~B~Y,~J~HS~~~::::::::::::::::::::::::~
~
7
~:::::::::J
f~ l::::::=±::::::::::::::::::=i~~::;;::;;;;;~~~::::::::::::::::::;;~==~======:.::.:::::J~~l~SS~U~EDA~TE~·~M~Af~20~1~
~
::
ACAD FILE NAM E:
579 16 - Be1 .dwg
OT
R ELEAS E D F OR CONSTRUC TION
BY:
DATE :
NAlJTI-H)RIZATIONOFPANHANDLEENGINEERJNG, INC
N
@PANHANDLE
ENGINEERING, INC. ALL RIGHTS RESERVED_ NO PART OF THIS CXX:: UMENT MAY BE REPRODUCED OR lJTILIZED IN ANY FORM WITHOUT PRIOR WRITTE
_J
James H. Slanina, P_E _39197
James M_Southall , P _E_ 39637
Christopher B _Forehand , P_ E_ 58028
Stephen E. Price, PE_ 7 1646
Jeffrey c_ Pete rmann . P_E_77540
ENGINEERING, INC.
ENVIRONMENTAL ENGINEERS · CIVILENGINEERS · LA~D p~~~~!
3005 South Highway 77 Lynn Haven , Flo n~a .
(650)763-5 200 Fax (650)769 -0 730 pe@panhandleengmeer1ng.com
SHEET NUMB ER
3
1----------:::=---·
qi
PROJ ECT NUMBER
CO
LYNN HAVEN, FLORIDA
DPR CERTIFI CATION #EB- 7806
57916-B
~
g:
FOR SCALE VERIFICATION AFTER DUP LI CATION, THIS LI NE SHOULD BE 1" LONG
10' DRAINAGE EASEMENT
NORTH LINE OF THE SOUW£AST
1/4 OF SECTION 15
l
10' DRAINAG E EASEMENT
I
I
I
I
I
c----------- - -
--------
-
-
,
!;"
\'\,GO
609. 70'
10' DRAINAGE EASEMENT----1
SYMBOL LEGEND
l1i9JI PROPOS ED
11 .28· DRAINAGE EAS EMENT _:~-
!
!
DRAINAGE INLET
~ PROPOSED FI RE HYDRANT
~
PROPOSED MAN HOLE
(Q)
PROPOSED MITERED END SECTI ON
IJl-'4
PROPOS ED VALVE
'
143.65'
~ PROPOS ED WATER METER
'-- -
'
-
- EXISTI NG CONTOUR
(Hl~N31 ~NOl\f
53 1 ~\fA)
PROPOS ED CON TOUR
'!',£· ~ ~
HA- "X" GEOTEC HAND AUGER LOCATI ON
'
m
.
~
N
0
0
~
S ITE B ENC H MARK
S ET 5/8"
IRON ROD &
CAP TRAY. No/ L S . .3961
~ L. =
.34.06 (NAVD - 88)
f----
r
z
m
O+OO
I
IDS-20
DS-40
())
aJ
n
·
N
l__
FOR SCALE VERIFICATION AFTER DUP LI CATION, THI S LI NE S HOU LD BE 1" LONG
'Jl,o: J~ ~ol!i I~~ 1
·
-
.
·
·
10' DRAIN AGE /
EASEMENT
111 -'
11 · .
,,.
~§~ ; ,__,
_ _ _ _ _ _
1
~lo ;
m
i'1 ·,~
@
,,
EASE~ENT--'-'-·- '
..
-----
s~
45
:
'
I
:
"
!; :::
_,"'
-
-
-
-
-
-
-
-
-
~
-
D
I
------ --
.if1 11--<
Q
~
55'
!
1
I
I
""
-~
-
1llIl l~'ii~ ~,n: '_~ --------~ ~-~---~ ~ ·i ~
:
111
11
·
I I.·
I
1 1···
.-,
I -
I
I
""
·
I
i
:
ti~-,1,..
1 1- -
@
,,.
- -
-
-
- -
-
-
- -
-
-
~
(.0.
®
't ·
-
ss-2 '
· '{
: ' .,
Ii
:' i i
I : ·.
I I .
g
I
~
·1 1 '
~
..
-1
~~ l1~1I
j
l
DRAINAGf:._.....-55,
I
e
~'r·'
~ ·-
-ll
II II
'
11
111
II"
I
'
I
I
I
-- 1' 'i'os-21
_L _____________
I I
:
@
"
@)
I
I I ·.
I, i
1·
!t
55'
r- -
-
-
-
-
-
-
-
-
-
-
-
-
®
I
..
'"'
·
·
',
l - -- j - - - - - 1 25'
I
-1 8'
1
MOD. TYPEECU~i:..:
55'
!'
:'
I
0
:i
y '.
HA- 6 _ /
I ·.
"
\
0------1r
111.34' -
\
,' R44 I
-..
R49' "
I
I
.
®
3 2. 2'
0. 7
11.oa·---,,0oc5_~23,1---.__,_-1---H---e1.6' -1
1
I
I
____./.
-~
:
I
~ \g-R15' 5'
"\(/___,__________ -
_
I
@
.I
~' I
'
'
·
Ill
~
1
SP-s
-
_,._,_;~~-: ..
_
.:· :
·..·
··1
·
..· '· ,·,
1
®
J
I
l-
;~'.,_.,, ·.. _. ",~;'.
'
HA- 8
,02.2··-----1--l'- - - 5 5 ' '- -+---1,- - - 5 5 '
1
____
f24\
I
:j
55'
I
i
@
55'
I jl
0
1
I
~
"
I
"0 .ti
e
~
:
@
I
55'
PROPERTY LINE
~
@
!
~~--:.-..-
..
"'~
I
-
~'.
-0'-:
··.
--- -
®
i
.
!
®
~
HA-;~o.8''
:
II
I
I
I
I
'
55'
,
\
~
I
I
"',..
,
-~
,
@
I
---
I
~
DRAINAGE
EASE~ENT
I
.
~ ---
-~
®
"··'~ '
~
,
l1 ~ !f
~!j
ii
' -
,
Ii
··
!
"~ I
I~
-
g~~~~~o~~-N~~~ L~.. 2372
1'
I ,::,I
~
I
B
\/
DRAINAGE EASEMENT
I
.... 1 :1
41_s5·\
________/
' lf
""
' \.
~ \'
I
""
~
I 1ii
'
.
·
.. '
,'
:
·"
'
·----.......
-
<<
0<~
- ~
"';- !
9i4'
~~~...
,,
®
...
, '
' / / R49'
~10'
" - - , , .
·
·
651 4 . 0B
'"
124.28'
I
-
... I "
'1
I
55'
II
I
I
I
I
I
-.".
'f
!
I
1
~
o
"'/ iI i
~
I
·
:
I~
'28'
I
'..·.
- ._
Il
w -
~--
___>%,
--·-·.·~··
1
I 1:
\
'"·
:
N 39 ·14'01"
1
1
0
//,
f-----
l.11.·
\ '· _.., ______ "' _____ ). _,_J :;
, 30 .~
os-18 :
I
1\'J "'
CALEI GH CIRC LE -
-
I
I
;
11'1
·;
_)
1- ~~ --
!
55
o "
i
.·
_j__,_____
I
1i1
I
,., _... I
I
.
I
1:1
,,,,,,. I
55'
11'1
1:11
l~I
11
I
,,,_,,. :
:
:: 1
I'l
1!1
'"
:11 :
~g
i
I"
,
i
_--~-------,1 ---"-~.~-------·;--
TIl
I
--+
:
" " ' ''
,_ SS-6
..........
i
®
I
,/
, 2.5'
DRAINAG E EAS EMENT
DS-17
r- -----
1
1
_ /-
N
z
::s0..
>0::
1-
w
446211 0154
::?:
SH ED EAVE OVERHANG
:
:
:
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
PROPOS ED CONTOUR
I011
I 1
1I
I
I
"1M .. 9
· .,..
1
®
w .OJ'
I
-
o
I
I
40th PLAZA
-
HA- "XM GEOTEC HANO AUGER LOCATI ON
-~ii
'C.J
I
I
I
I
I
1'1
I
0
1
"
11
?"': 1
I1
· i
,, ___________ _!_15'~j
I
_ . ---r LR2s·
":: 1 '
" 1:: I
I
E-
"
- EXISTI NG CON TOUR
1
1Ill1
I
I
2601
m" .."!
-
1
ii
I .i
ii
J
. 10+ 00
'cALEI GH CIRC LE
wc====:.:'.-=---L_L
~ DEN~TES
II
'
1 1·1'
Ii 1,i II
1
1
lr.0'
9 + 00
j
-·
'i~---
-j,....__J,,~:"1_'____
\f
I
'"
I
~·1- "-·t~~~~~~===~~.-"'\~~==~l-\
I_·
r
I
,___
~
..
-·".'
I/
N
- - - i - - - -
"'·"·
/
PROPOSED VALVE
I ij
\;/
t=::..-op~
Ill "'
ro
I
I
/ . ..
': v
:-1
I'
@
I
8'
~~7°R44'
, -.:-
,<:"
l,- ~. 1~-~/: ,,,,,/
·'
It
I
~c
_,
I
'
1'1M .. 5'
,, (.,'.", .
1
30' ·
,: 1
I
'
I
\ / ··
_,.,./
:i1 I(/)
-I
@
I
-
r_
·
_ _ __ l_J
1'1
I
:t
i
55'
11- 2r - 1!1 l' ·,
R25/~?/
N"
Ij~h
I~ ' ~-j----
;., .
1i1
·.~~30', s~·.
I
@
~'I
I
@
:,
11'1 l' .
11
·
'
::1 :
o
m1 ~ · _,, .p.
'-----'- - - - - - - - - - - - - "-' - .;·
'
Ill
i
@
li>'\lll
I
·
l """"'m
-_~L____________
111os-1 ·
I
: 1~ 't:21ij_,Ll :11: ~C 1 :
,
@
55'
,I,
11
11
11
1I'1
'·
J'
-.
~:
-
I
::: : -_ 1 :
:1:
I ~.
111 "'
:; " : 1
55'
PROPOSED MITERED END SECTI ON
-----
: I :·~::: :: : ._ ~~------------ -----1 L --------------~-1 ;~ : ::I i: I-~------------- ~ ~
I':,
!
;I
l; ------------ ]~I ~b ,· -~ ~ !I ~~
~
®
I
i! 1 .~ : : ':i: : :- ~ -------------- 1 _______________ J~" : ~ :: -~~ ------------ 1.i
I~
:!
PROPOSED MAN HOLE
1
,,
I
: I I
-I I
f·
""
~~ -~_._~·J .i
·
@
1 .,
·
-A'
((i)
~ PROPOSED WATER MITER
v~=
11
PROPOSED DRAINAG E INLIT
~ PROPOS ED FI RE HYDRANT
1
· 1·
1·i·
~ ~~~------------
:::
;t - ,1,
11
', "'
I
~
·. 1 :
1
11 :
I
f.1-
(;";-.,
·
llmJI
I
@ - - ::::. ·: ·: · 1 11
·
:1:"
I 1
·
II
'I
.J
,
· · ' '
·· ·.
· ·
111 _ ;'.-1: - - - - - - -
I
·
· " ·· ' · - 55'
, ..
:I.l ~1 :: 1·. I :
-
@
p,1
·
·.' I I
·· I
,1,
11
·
·
SYMBOL LEGEND
iDS-19
··. : ... ,,.· )I !I
@
; 1 ~ : --
:I
·
,
:
11 ' ; I I
,,,I
··.' ~I
I .I
I '
+-
I
V"icl..),i
10'
I
I
··
.,
: '· I
1'1
I ·;
".'.Y
11
I
1:.:
-- IO
____________ i _J ·~sl 1""0·
:. OS-24
©
©
-
:
I !I
55'
·
i
I
ro
@)
~· I
11
,
' ii
i
N
-
@
I
1
I
11
I I
11 ,
I
8+ 111 '
I
_:
- 5
I
_:·I
rm
1 ".""'!~ ';-..
55'
-
!I i:~~---------~ 11---------------JJ' !!I,,-~------------- i i I
i ;,
I
I
!'
!
N
-
-
"
-it
:- I I
I
I
;<
J
55 '
-
-
~::._~------------ _J it ~--------------
Ill
,··
®
-
,
I
·
11
,1,
I I '·
I
-
'j' ··
. I :
1
8 11
;;
,_____,_ - - - - - - - - - - - - --+ _J
~ ~
:::
0
-
·
::: "'.· 1 :
~
-
I
55'
':t_L ____________
111
I J .'
_ _
@
.. I I
{
I
111
1'1
:t
I
~S-2~ --
1
1
:':,-r------------ 111---------------r> i·
1!I
I I '~
I.'
@
I
I
}
·O
!
- - - - --- - ---
._ I I
1·1. I I
1
11 <' I
l ~I
;
I
I
i
1i1
·
'--'-------------i ,,:
t:
.
·'" I' -Yo·"
.
I 1.· I
I I·
l j ti
I
'"
--·
@
55'
"
11.17' DRAINAG E
!
--------------+I
·
·
'
·
·
2611
E.
40th Pl_AZA
2615E.
40th PLAZA
I
1
1
I
I
I
I
I
I
2625E .
"-0th
PLAZA
I
I
I
I
I
I
I
I
'
T613351.7025
f------
0
w
CJ
2637 E. 40th PLAZA
w
1(/)
I
1::J
0
(/)
FOR SCALE VERIFICATION AFTER DUP LI CATION, THI S LI NE SHOU LD BE 1" LONG
SANITARY SEWER STRUCTURE TABLE
TOP ELEV
PIPE
INVERTS
SS-'
SANITARY
SEWERMH
40.18'
(N) 35.00' {SP..1)
SS-2
SANITARY
SEWERMH
39.33'
(S) 33.24' (SP-1)
(N) 33.14' {SP- 2)
SANITARY
SEWERMH
38,00'
(S) 31.14' (SP-2)
(W) 30.40' (SP-4)
(NJ 30.50' {S P..3)
Ss-1
SANITARY
SEWERMH
35.60'
(5) 31 .50' (SP-3)
SS->
SANITARY
SEWERMH
38.02'
(E) 28.80' (SP-4)
(NJ 28.64' {SP..9)
(W) 28.50' {SP-10)
(S) 30.44' (SP-7)
SS-<
SANITARY
SEWERMH
1O' DRAINAGE EASEMENT
--- ---
c--------- - - -
- - - - - -609.70'
--~--
SS-3
---
'
-------------'·
10' DRAINAGE EASEMENT
I
'
(W) 35.71' (SP-5)
SANITARY
SEWERMH
40.21'
(E) 34.43' (SP-5)
(NJ 34.34' {SP-6)
SANITARY
SEWERMH
39.33'
SANITARY
SEWERMH
35.70"
SS-10
SANITARY
SEWERMH
38.!!3'
(E) 30, 11" (SP-8)
(S) 30.00" (SP-9)
SS-"
SANITARY
SEWERMH
38.50'
(E) 27.60' (SP-1 0)
(S) 27.50' (SP-11)
(NW) 26.00' (SP-12)
SS-12
SANITARY
SEWERMH
39.00'
(N) 27.33' (SP..11)
SS-7
;,
SS-e
n
n
SS-S
."
I
w
n
TYeE
40.66'
I
~
STRUCTURE
;.,
N
n
n
N
m
~
S ITE B ENC H MARK
~
S ET 5/8" IRON ROD &
N
0
CAP TRAV. No/ LS. 3961
EL . = 34.06 (NAV0 - 88)
~
EXIST. WETLANDS
SP-1
SM
(SJ 32,54" (SP-6)
(N) 32.40' {S P.7)
DESCRIPTION
LF
SLOPE
INVERTS
,.
8" PVC Pipe
352'
0.50%
SS· 1 = 35 .00'
SS·2 = 33 .24'
,.
8" PVC Pipe
400'
0.50%
SS-2 = 33.14'
SS-3=31.14'
8" PVC Pipe
200'
0.50%
SS-4 = 31 .50'
SS-3 = 30 .50'
8" PVC Pipe
320'
0.50%
SS-3 = 30.40'
55·5 = 28.80'
a· PVC Pipe
256'
0.50%
SS-6 = 35.71'
SS-7 "34.43'
6" PVC Pipe
359'
0.50%
55.7 =34 ,34'
55· 6 = 32 .54'
8" PVC Pipe
393'
0.50%
SS-8 = 32.40'
SS-5" 30.44'
8" PVC Pipe
278'
0.50%
55·9 = 3 1.50'
55· 10=o30.11'
6" PVC Pipe
273'
0.50%
SS-10 = 30.00'
SS-5 = 28.64'
SP~
,.
,.
,.
,.
SP-7
,.
SP~
SP~
SP~
SP~
,.
,.
SP-10
,.
s· PVC Pipe
179'
0.50%
5P-11
,.
55-5 " 28.50'
S5· 11 " 27.60'
a· PVC Pipe
33'
0.52%
SS-11 =27.50'
SS-12 = 27.33'
(W) 31.50' (SP-8)
r--------,·
~
~
c
I
m
f----------1
z
SIZE
SP~
n
SANITARY SEWER PIPE TABLE
~
Ill
n
m
n
N
n
--------1
0
"
'--------
I
I
I
_j
I
I
I
m
-I
N
-,
J
15'±
ID
DRAINAGE
EIA SEMENT
C\J
I
I
I
I
-1
-------1
I
I
-_j
I
I
w
n
N
n
n
~
SYMBOL LEGEND
llmJI PROPOSED
w-
-
-
-
-
-
-
-
-----,
DRAINAG E INLET
~ PROPOS ED FI RE HYDRAN T
LJ
~
PROPOSED MAN HOLE
(Q)
PROPOSED MITERED END SECTI ON
~
PROPOSED VALVE
~ PROPOSED WATER METER
'
-
......_ -
- EXISTI NG CONTOUR
PROPOS ED CONTOUR
HA- "X" GEOTEC HAND AUGER LOCATI ON
FOR SCALE VERIFICATION AFTER DUP LI CATION, THI S LI NE SHOULD BE 1" LONG
DRAINAGE STRUCTURE TABLE
STRUCTURE
\
I
---- ---
- -~-
FDOTTYPE E
INLET
DS-2
FDOTTYPE E
INLET
DS-3
FDOT TYPE E
INLET
30.65'
DS-5
FOOT TYPE E
INLET
37.62'
(W) 32.50' {OP-5)
(E) 32.50' (OP-19)
DS-6
FOOT TYPE E
INLET
37.55'
(E) 32,25' (DP-5)
(SJ 32.25' (DP-4)
(W) 32.25' (OP-10)
DS-7
FDOTTYPE E
INLET
39.59'
(W) 35.70' {DP-6)
DS-8
FDOTTYPE E
INLET
39.62'
(E) 35.50' (DP-6)
(N) 35.50' (DP-7)
DS-9
FDOTTYPE E
INLET
38.67'
(W) 34.70' (DP-8)
DS-10
FDOTTYPE E
INLET
30.71'
(E) 34.50' (DP-8)
(S) 34.50' (DP-7)
(N) 34,50' (DP-9)
1-------
-I
SIZE
DP-1
DESCRIPTl0N
LF
SLOPE
INVERTS
RCP
27'
0.37%
OS-i = 36.60'
DS-2 = 38.50'
OP-2
18"
ADS HP STORM
275'
0.73%
OS-2 = 36.50'
OS-4 = 34.50'
OP~
18"
RCP
27'
0.93%
DS-3 = 34.75'
OS-4 = 34.50'
DP4
,..
ADS HP STORM
295'
0.76%
OS-4 = 34.50'
OS-6 = 32.25'
RCP
27'
0.93%
DS-6 = 32.50'
DS-6 = 32,25'
RCP
29'
0.70%
OS-7 = 35.70'
DS-8 = 35.50'
DP~
'"
DP~
DP-7
18"
ADS HP STORM
275'
0.36%
OS-8 = 35.50'
DS-10 = 34.50'
DP~
18"
RCP
29'
0.70%
DS-9 = 34.70'
DS-10 = 34.50'
DP-9
24'
ADS HP STORM
309'
1.13%
DS-10 = 34.50'
DS-13 = 31.00'
DP-10
JO"
ADS HP STORM
147'
0.34%
OS-6 = 32,25'
DS-11 = 31.75'
DP-11
36"
ADS HP STORM
147'
0.34%
DS-11 =31 .75'
DS-12 = 31.25'
OP- 12
36"
RCP
27'
0.93%
DS-12 = 31.25'
DS-13 = 31.00'
(E) 31.75' (OP-10)
(W) 31.75' (DP-11)
(S) 31 .75' (DP-21)
DP-13
42"
ADS HP STORM
139'
0.38%
DS-13 = 31.00'
OS-15 = 30.50'
IYVl 31.25' (OP-12)
DP-14
18"
RCP
26"
1.80%
DS-14 = 31 .00'
DS-15 = 30.50'
DP-15
42'
ADSHPSTORM
117'
0.43%
DS-15 = 30.50'
DS-16 = 30.00'
OP.16
18"
ADS HP STORM
277'
0.18%
DS-17 = 35.00'
DS-18 = 34.50'
DP- 17
18"
ADSHPSTORM
330'
0.15%
DS-18 = 34.50'
OS-19 = 34.00'
DP-18
18"
ADS HP STORM
282'
0.35%
DS-19 = 34.00'
DS-20 = 33.00'
DP-19
24'
ADS HP STORM
147'
0.34%
DS-20 = 33.00'
DS-5 = 32,50'
DS-11
FOOT TYPE E
INLET
36.33'
DS-1~
FOOT TYPE E
INLET
37.74'
DS-13
FOOT TYPE E
INLET
38.00'
(E) 31.00' (DP-12)
(SJ 31.00' (DP-9)
<:N) 31 .00' (DP.13)
FOOT TYPE C
INLET
37.59'
(S) 31.00' (DP-14)
(N) 31.00' (DP-27)
DS-15
FDOTTYPE E
INLET WITH 6'
ROUND
BOTTOM
38.01'
(N) 30,50' (DP-14)
(E) 30.50' (OP.13)
{SW} 30.50' (DP-15)
OS-Hi
PIPE ENO
32.72'
(NE) 30.00' (DP-15)
DS-17
FOOT TYPE C
INLET
38.33'
(N) 35.00' (DP-16)
DP-20
18"
ADS HP STORM
275'
0.36%
OS-21 = 35.00'
DS-22 = 34.00'
[IS-18
FOOT TYPE C
INLET
37.83'
(S) 34.50' (OP-16)
(N) 34.50' (DP-17)
DP-21
18"
ADS HP STORM
295'
0.76%
DS-22 = 34,00'
DS-11 =31.75'
DS-19
FDOTTYPE E
INLET
37.33'
(S) 34.00' (DP-17)
(N) 34,00' (DP-18)
DP-22
18"
ADSHPSTORM
341'
0.15%
OS-23 = 35.00'
DS-24 = 34.50'
DS-20
FOOT TYPE E
INLET
37.33'
(S) 33.00' (OP-10)
<:NJ 33.00' (DP-19)
OP-23
18"
ADSHPSTORM
330'
0.15%
DS-24 = 34.50'
DS-25 = 34.00'
DS-21
FOOT TYPE C
INLET
38.33'
(N) 35.00' (OP-20)
DP-24
18"
ADS HP STORM
92'
4.34%
OS-25 = 34.00'
DS-26 = 30.00'
FDOTTYPE E
INLET
18"
ADS HP STORM
67'
6.01%
37.33'
(S) 34.00' (OP-20)
(N) 34,00' (DP-21)
OP-25
DS-22
DS-27 = 34.00'
DS-28 = 30.00'
FOOT TYPE C
INLET
DP-26
18"
ADSHPSTORM
265'
0.19%
DS-23
38.33'
(N) 35.00' (DP-22)
DS-29 = 32.00'
DS-30 = 31.50'
FOOT TYPE C
INLET
18"
ADS HP STORM
72'
1.38%
37.84'
(S) 34.50' (OP-22)
(N) 34.50' (DP-23)
DP-28
DS-24
OS-31 = 33.00'
OS-32 = 32.00'
FOOT TYPE E
INLET
18"
ADS HP STORM
142'
1.06%
37.33'
(S) 34.00' (OP-23)
(NW) 34.00' (DP-24)
OP-29
DS-25
OS-32 = 32,00'
DS-33 = 30.50'
(SE) 30.00' (DP-24)
18"
RCP
26'
1.92%
PIPE END
32.18'
OP-30
DS-26
OS-33 = 30.50'
OS-34 = 30.00'
DS-27
FOOT TYPE C
INLET
38.58'
(W) 34.00' (DP-25)
DP-31
24'
ADS HP STORM
58'
1.72%
DS-34 = 30.00'
DS-35 = 29.00'
DS-29
FOOT TYPE C
INLET
36.35'
(S) 32.00' (DP-26)
DP-32
18"
RCP
25"
1.97%
DS-36 = 34.50'
OS-37 = 34.00'
DS-31
FOOT TYPE C
INLET
36.35'
(N) 33,00' (DP-28)
OP-33
18"
ADS HP STORM
48'
8.28%
DS-37 = 34.00'
DS-38 = 30.00'
DS.02
FOOT TYPE C
INLET
36.90'
(S) 32.00' (DP-28)
(E) 32.00' (DP-29)
DP-34
24"
RCP
,,.
0.44%
OS-39 = 31.60'
DS-40 = 31 .20'
DS-33
FOOT TYPE E
INLET
34.87'
IYVl 30.50' (OP-29)
(NE) 30.50' (OP-30)
DP-35
24"
AOS HP STORM
44'
2.27%
DS-41=31 .00'
DS-42 = 30.00'
FDOTTYPE £
INLET
34.68'
(SW) 30.00' (DP-30)
(NE) 30.00' (DP-31)
DP-36
24'
ADS HP STORM
ur
1.77%
OS-43 = 29,50'
OS-44 = 29,00'
DS-35
PIPE END
31.18'
(SW) 29.00' (DP-31)
DP-37
18"
ADS HP STORM
282'
0.35%
DS-45 = 33.00'
DS-46 = 32.00'
DS-38
FOOT T'l'PE C
INLET
37.54'
(S) 34.50' (DP-32)
DP-38
18"
ADS HP STORM
49'
6.15%
OS-46 = 32.00'
DS-47 = 29.00'
DS-37
FOOT TYPE C
INLET
37.54 '
(N) 34,00' (DP-32)
(S) 34.00' (DP-33)
DP-39
18"
ADS HP STORM
65'
1.53%
DS-48 = 31.00'
DS-49 = 30.00'
DS-38
PIPE END
31.64'
(N) 30.00' (DP-33)
DS-39
MITERED END
SECTION
33.85'
(S) 31 .60' (OP-34)
OS-40
MITERED END
SECTION
33.45'
(N) 31.20' (DP-34)
DS-41
FDOTTYPE E
INLET
37.35'
<:'N) 31.00' (DP-35)
DS-42
FDOTTYPE E
INLET
33.52'
(E) 30.00' (OP-35)
DS-43
FOOT TYPE£
INLET
34.50'
(E) 29.50' (DP-36)
0
""
39.56'
(E) 36.50' (DP-1 )
(N) 36,50' (DP-2)
FOOT TYPE E
INLET
I
I
<:NJ 36.60' {DP-1)
(E) 34.50' (DP-3)
(S) 34.50' (DP-2)
(N) 34.50' (OP-4)
l' l
~·
39.54'
(W) 34.75' {OP-3)
DS-14
-------------!
NO.
30.63'
---- ---
m
PIPE
INVERTS
TOP ELEV
""''
DS-1
DRAINAGE PIPE TABLE
_,
SYMBOL LEGEND
(E) 31 .25' (DP-11)
NOTES:
SEE SHEET 12 FOR STORM BASIN DISCHARGE
STRUCTURE DETAILS.
1.
-
S ITE B ENC H MARK
SET 5/8" IRON ROD &
CAP TRAV. No/ LS. 3961
_f l . = 35.05 (NAVD-88)
\' ~I
-;
W
l>
/
,.,
j
:...
~
_..,,.
' '
,
~
-r
1
I
~
'
.:r:
1
./
~A
.' --.....
I
//
I1
,· "
TYPICALEXISTNGGRADECONTOUR""'/ /
..,
4l
___
~
~
-
""
w
-
-
-
-
1
~-
DS-2'
~/-,-- - DENOTES SET. 4"~ 4"
CONC. MON. No. L'if· 3691
I
I
~
~
~
I
~
I
I
1
..
~
..
I
I
l\.
I
- - :1--- -
,
~ -/ ~ j/
L
I
I
'~,,....._
:::--/y
I --.....__
I [~
r:;::.,
I 'd
@
( ~~
I
--"""(31)
\
..ci
;.._
1
-
I
/
I
PROPERTY LINE
I
I
N
89'14'01"
W
II
I
!
·NG
DEN TES SHED EA VE OVERH"
1
40tr1 ?LAZI'
-38 -
I 2~YE:.--:; 0\h
I _...
-
-
PLAZA
- -1- --I
I
I
6 54 · 08 '
"'- 1
"
I
10'
DRAINAGE
I
I
- ; ; 61!;.. E
"IO1
I
/
·:~
. ·
·
I '
·
I
' ' J\.·-~
~ "'
I
j
~
j
~
4-~
I
E_.
"'Ott> f'LAZ/'.
I
I
1
,.,
rI
i
I
I
~
/ E XIST. WETLANDS
Ii
I
r
"
1
\
J] '11'.'.
_'j,
~
N
~
0
lfl
I--------~
I
CTI
.l'\j
LO
-
-
-
-
-
-
-
-
~
'o:::::
~~:EENT
1
; sr~-----------i
*SIDEWALK 4" THI CK .3000 PSI PCC
(TYP. BOTH SIDES) CONSTRUCT
CONCURRENT WITH ROADWAYS
FOOT/ADA TRANS ITIONS REQUIRED
------
II
~11.0'
8.0' UTILI TYP/ L
~
~
?
GAS
40tn PLAZ"
J
6
:;,
~
POTAB LE
_
"'
MIN) z
)?
WATE:A~~ER
I-
'
.:,.SLOPE
.02·:,'SLOPE
Z
~=- ,, ~
z
MODIFIED TYP E
" E" CURB
FOOT INLIT (SIZE &
LOCATI ON AS SHOWN
ON PLANS)
~
u...
.36" MIN
J
~
7 o·
1.0·
SANITARY
SEWER
0
~
11.o·;i,_ ·
6 3
(TYP. BOTH SIDES)
SUPPLY TO SANITARY SEWER
(TYP. BOTH SIDES) 6"11l SINGLE
SERV ICE 10' 0/S PROPERTY CORN ER
I
R'i..'.o
a:::
.::::::
T't'PICAL STRUCTURE
' - .3"
HYDRANT
W
I-
INTE RS ECTI ONS PER LYNN HAV EN CIT'!' COD E)
..---
\
4"
DENOTES ro .
CONC. MON. No. LB 2372
N 44621 1.0154 E
1613351.7025
2£>37 E
~
STREET LI GHT
(PLAC E STREIT LI GHTS EVERY 400ft. MIN. AND AT
EASEMENT
2625
l
N
·
"" "- - - ' '
-...:...:,/
Al
,-
'
1 . 1·\2 ~-<~ ~i c~,_jl~..~1 ~ L-- '~/~
1 , , ~ ,~, d _
I
26 0 1 E
CI RC LE ~'
CIRC LE .SP-S_ "f""l _ _ CA LEI GH
TYP ICAL PROPOSED LOT GRADING CONTOUR------.;__
I
~
0
"~ ~
j
I
~~
~ ,~ ~- SS-7_,,sA~.EI GH
'
0::
W
ro~~~R~AI N
TELE./ELEC./CAB LE
I-
(TYP. BOTH SIDES)
(fJ
ELECTRICAL PAD MOUNT
TRANS FORMER
(T'l'P. BOTH SIDES)
~
0:::
w
I
I
I
I
(
·
\
I~-·
I
I
JYPICAL ROADWAY SECDON2 LANE 60 ROW,
~
.._.
NOT TO SCALE
>
~ .......,,....,..,..,..,..,..,,_..,..,,....,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,_..,..,..,..,..,..,..,_,..,..,..,..,..,..,..,..,..,..,.,;..,..,_,....,..,..,..,..,..,..,;.,..,..,..,..,..,..,.,._,..,..,..,..,..,..,..,_,..,..,..,,...,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,_,..
,,·m·~
..,
" ·'·
"·
"'·
",·.·
P·
,·,·
,·
,,·
, _,..,..,..,..,..,..,..,..,..,..,..,..,..,....,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,4:;;
~E
~
~
REV
DATE
BY
REVIS IONS
SCALE c AS NOTED
0 - - - - + - - - - - - - t - - - - + - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - O t - - - -D
_E_S_l_
G_N_E_
D_ B_Y_c _ JH_S
_ _ _ _ _ _ _ _ _ _ _ _ _-11
R~:::~ :: ~::
·
··PANHANDLE
·
·
ENGINEERING, INC,
STORMWATER MASTER PLAN
Stephen E. Price, P_E_ 71646
ANDREWS PLANTATION SUBDIVISION
-
i'o
~
,,m~M'°""'"· Pceoee'
ChristopherB _Forehand, P_E_58028
"~eyC.PeSHEET NUMBER
7
57916 B
CO
~
PROJ ECT NUMBER
ISSU E DATE :
MAY 2017
0----~------~--~--------------------------------0f------------------------·
ENVIRONMENTALENGINEERS ·
CMLENGINEERS .
LANDPLANNERS
3005 South Hig h way 77 Lyn n H aven , Florida 32444
LYNN HAVEN FLORIDA
Cl'.
Q
I-
~'
°'
NOT
R ELEAS EO FOR CONST RUCT ION
BY:
DATE:
ACAD FILE NAM E: 57916 - Be 1.dwg
(850)763-5200
Fax (850)769-0730 pe@panhandleengineering.com
1
DPR CERTIFI CATI ON # EB - 7806
f'-~ 1!!<-.........................................................................................................................................................................................................................................................................................................................................................
0
L!"J
@PANHANDLE ENGINEERING, INC. ALL RtGHTS RESERVED_ NO PART OF THIS DOCUMENT MAY BE REPRODUCED OR UTILIZED IN #N FORM WITHOUT PRIOR WRITTEN AlJlljQRIZATION OF PANHANDLE ENGINEERJNG, INC.
FOR SCALE VERIFICATION AFTER DUP LI CATION, THI S LI NE SHOULD BE 1" LONG
DRAINAGE STRUCTURE TAB LE
NO.
DS-12
DS-13
DS-14
DS-15
STRUCTURE
FDOT TYPE E
INLET
FDOT TYPE E
INLET WITH 6'
ROUND
BOTTOM
38.01'
PIPE ENO
32.72'
FOOT TYPE C
INLET
{W) 34.00' (DP.25)
DS-36
FOOT TYPE C
INLET
DS-37
FDOTTYPE C
INLET
37.54'
(S) 34.00' (DP-33)
DS.3'
PIPE END
31.64'
(NJ 30.00' (DP-33)
DS-40
"3""
DP-13
.,.
SLOPE
INVERTS
1.13%
DS-10 = 34.50'
DS· 13=31.00'
0.34%
DS-11 =31.75'
DS-12 =31 .25'
0.93%
DS-12 = 31.25'
DS-13=31 .00'
0.36%
DS· 13=31,00'
0$-15 = 30,50'
309'
ADS HP STORM
147'
RCP
,,.
139'
ADS HP STORM
DP-14
18"
RCP
,,.
1.80%
DP-15
.,.
DS-14 : 31 .00'
DS-15 = 30.50'
ADS HP STORM
117'
0.43%
DS· 15 = 30.50'
DS·16 = 30.00'
DP-25
18"
ADS HP STORM
6T
6,01%
DS-27 = 34.00'
DS-28 = 30.00'
0.19%
DS-29 = 32.00'
DS-30 = 31 .50'
1.97%
DS-38 = 34.50'
DS-37 = 34.00'
8.28%
DS-37 " 34.00'
DS-38 = 30.00'
DP-26
(E) 30,00' (DP·25)
PIPE ENO
30.00'
(S) 34.50' (DP-32)
37.54'
18"
DP-32
(N) 34.00' (OP-32)
ADS HP STORM
19"
DP-33
265'
25·
RCP
18"
'6"
ADS HP STORM
I
I
I
I
I
I
I
I
I
I
SS~
SS-11
TOP ELEV
TYPE
SANITARY
SEWERMH
38.02'
SANITARY
SEWERMH
-
'--
SANITARY
SEWERMH
NO.
(E) 28.80' (SP-4)
(N} 28.64' (SP-9)
(W) 28.50' (SP.10)
(S) 30.44' (SP-7)
SP-4
SIZE
(NJ 27.33' (SP-11)
SS-13
Concentric
Cylindrical
Structure_OFth
38,70'
(SE) 28.56' (SP.12)
(N) 28.77' {SP-13)
SS-14
Null Structure
29.73'
(S) 29.00' (SP-13)
SP-9
SP-11
CENTERLINE
CASON DRIVE
\
I
SHE~
8" PVC Pipe
8" PVC Pipe
"
SLOPE
INVERTS
320'
0.50%
SS-3 = 30.40'
SS-5 = 28.80'
0.50%
SS-8 = 32.40'
SS-5 = 30.44'
393'
8" PVC Pipe
273'
0.50%
SS-10 = 30.00'
SS-5 = 28.64'
8" PVC Pipe
179'
0.50%
SS-5 = 28.50'
SS-11 =27.60'
0.52%
SS-11 = 27.50'
SS-12 = 27,33'
8" PVC Pipe
33"
SP.12
,.
8" PVC Pipe
112'
0,50%
SP.13
,.
8" PVC Pipe
,,.
SS-13" 28.56'
SS-11 "28.00'
-1.00%
SS-13 = 28,77'
SS-14 = 29.00'
;~:~~:-
m
nN
N"
+ ~
c
\
.,,
(NAVD - 88)
\
\
j
\
1 111
I III
..
,..,\
\
TREE ON
\
II
~4~1
'
INV IN: 27 . .3.3'
~
~~
.~
+
0
""
~
~ w
v.
0.00%
<=-003
~
39
\
36
36
"lo
"':39
' " "\
.3-
~
lfl
,;,
4
-------'~,
\\~I ~ ~
-:::--- ' \
"'
=:;_::__
-
"'
-
" .
=
-
,
6+00
5+00
00
+I
-
-
CASON DRIVE
I
' ,,
_..
=---"-
/:.~
7 T
-
-
"'i
/
DS- 14
0-0
g
0
-
::..
== .- "
,.---
15
v
/~;
~ v-
-----~--~·~··.-~
·~~.-..·.. -.. -__ -~-
-
/
7_++o_o_
-==
, ,__
\\
\
1~
9
iDS'.38
I
34
33
/
"
"'°"""""
\\
//
'
-
·.
'\
R~!
\
.
\:
,
I .
__
ii·
I
SP
11 33' 8"
-
;
\
\
SS 12
~
.
,_.,
~
_ - -- f
I, ,,
,I I
-.,
I
~
!9
'"
,.,
11
1
DS - 15
FOOT TYP E E IN LET WITH 6' ROUND BOTIOM
!~:~t~~~·~3.6'
/PROPOSED FINISH GRADE
(EXISTING GRADE
\i
w
g~=i ~ : ~0RI: ~~ ~~:~g:~
8
~8
8~
+ 00
"111
~;ll.
~~
v'
8 C!
I
/ /
·
: ::
DP - 15 INV OUT: .30.50'
DS - 13
FOOT TYP E E INLET
RIM: .38.00'
DP - 12 INV IN: .31.00'
DP - 9 INV IN: .31.00'
DP-1.3 INV OUT : .31.00'
~8
~8
:2 ~
+~
OITT
ITT .
+
+ ~
~ __Jw
00
""
~
~;!l.
~~
HA- 2
" ~
ci
STA= 8 + 27
EG EL=38.6
-- -
ESHGW
36.2'
=
'
-
-J---4"----=~~~_.c:_~:::::--------l----------------l--------===~~;:=::::;~"i'::''-;=::::::::;;;;:::;:.;::::::::::::::::::::::::::::::::::::_---f______________---f______________ni'"-noneo...fO~s~1~4~_,,.~
.3.3
'\,/ - DS - .36
I
\
DS .37
F OT TYP E c IN LET
FDOT TYP E c INLE1:. _!
FOOT TYP E c INLET
RIM: .37.59'
\MATCHEXIST.GRADE
PVC----Fip~
.
,\
1
/ ; ! .L _ /~/,@/ -! I :~ ~,
L
'\___________\_\_.,__,_____._~_O_R_M_W_A_T_E_R_B_A_S_IN_N_o_._,_· ,_,_'_,~·------------\-._·,_,_:~~-·-·~D,o/~~ -~ !//!~___ : clrr·-=11i~-r \
I
I'
30f----\"------------t---------------t---------1'f..,_-"'CS.>"--f-t---~"""
" ~·-.;;.-n.:,·4~·----c------t-----------------t-------------BP--/q__,N'J-4.,_.;;{..9'~"----
27
/
.
36+----li~~
-.:;;;""'~-----+------==--=olc---.~~~+-------~C..,,~~c-.=~~
~:=::::::::::::::::::::::::::::::::::::::::::::+:::::::::.::.~============t=======================r======~~~==~
t----1 ~
30
~
I
1 0~ 2 ,
DP-12
I
I
I
1
- ..·..,· I I
-
.J
'i..-HA- 2
. _.. . -'(;
~~- I
v.
"
; ~·:'<,.
V
j
~
F
,··'"=-----=-----,.
I s -1.3'~
-DP.13
Rt,~o-.
. ,· ..
~=~-~~~~~~~~~~~~~~~~~-~~-~·~--~-~- ~-~--~·~-·~·~··;·-~-~-~~-~-~~-~~~~~~~~~~~~~~~~~~~-=~, ~
~~~
a
w
_ _ _c
~A~S~O~N-O~R~IV~E'---~~·-'lf-o-ll----+ ~
w::::::::::::::::::::::::=:::=.£;;"¥"~""""~~~~~~~-~--t-~~-~-::"=m":'""'":=':::;"~~:::::t=:::::::;;;::::;;;;;;:::::::::~~w;.;\jj,;:::;::::;1""~:;::::::::::::::::!o::::::::;e~~
t--;J~~n~·----------:t:::--"'f~~--'-~~~~"'-~~~~""'i:::;"!'.::!:20::::::::::::;j::.:::::::::::::~
4
~~
~.sB"'·----/
1
-- -- - - ~ - - -- ~ _-_- _ _ __ _ _ __ - - 1-- - - - - - - - - - - - I--
30
~-
~ --
-
1- -
33
33
~
-~
DS-36
·
-
-
?>: /
610.49'
HA- 1
+
tnm
89~3'~5" w
SS- 14
____
~ ~
u
42
"
PROPERTY LINE
1
'
- --
\
~-c~;,.-___..-- ~
~ ~
w
\
N
-r:. )~~,~-
~ r;:;
(!; w
"\
I
\
\__,
-llGH PT. STA: 1 + 20.9(
HIGH PT ELEV: 38.89
~
c~
""
I
I
I
HA - 1 \
P\11 STA: 1 +00.00
PVI ELEV: 39.00
K: 8.23
LVC· 50 00
m
"
_
.
~
··· ·.. .
- - -- -
\
~.
~~t~i _ rr~~ ',,~
0
0
.
I
I
\
-rm,- ~:1 1 ; ,, / , · ·
SS - 12
SAN ITARY SEWER MH
RIM: .39.00'-
I
1
1
2+00
----
I,
I
\
-
·
L-,-~-1~
/
\
'3
jl!J.11 " )/ '.I .I·
/
/
I
\
--
/
/
I
I
\
\
__
1t! .~t', - ~, '
·
I~
I
I
I
...
/
I
I
c~
~ w
39
I
9JAP TRAV. No/ LS. 3961
I \
\36 " PINE
I \ / CORNER
/
FOR THE REUSE MAI N AND
ITT 0
~?
"
11
~
S T 5/8" IRON ROD &
'ttr~ l
e-i-tl-clj~l----l·~
l---1'I'-/ ~-1_++tdo;:-__1
l-i
o+.oo
I I
I
'"""
I
l BORE
o";~ ~:~:T~~~~~~
C!oSP - 11
w·
II
: i :: :
'
ITT ITT
I I I
1 11 1
I
Oo
Oo
Oo
\
/
S!TE B ENC H MARK
:-\= 34.06
I
I I
I
I ·
I
I
\
'~I\ j
-
OS-3?~
-=\ \
) \"1
DI RECTIONAL -~-+.!-ll ,~~~~
'!
I
I
\
I
\
I
\ I
I /I 11
I // I 1
II I I
13 FOR
OFFSITE WATER_
-
I I
I I
v
I
I
I
I
I
I
I
I
I
I
I
.-''
...
__ - -Q- "'
/
/
~I
I;
I
I
\
\
i
SS - 11
SAN ITARY S EWER MH
RIM:
SP - 10 INV IN:
SP - 12 INV IN: 28.00 '
SP - 11 INV OU T: 27.50'
N ITT
0
DESCRIPTION
,.
,.
,.
,.
,.
SP.T
39.00'
ITT
--::;;,_
/
~1
I I
I I
I I
I I',\)\\
SANITARY SEWER PIPE TABLE
SP-10
SS-12
I
I
-
SEE,
PIPE
INVERTS
CD
f
I
(E) 27.60' (SP-10}
(S) 27 .50' (SP-11}
(NW) 28.00' (SP-12}
38.50'
;u
w
,.,; /
I
NO.
()
I \
SANITARY SEWER STRUCTURE TABLE
I \
I I I
I I I
II I
II
I
II
I
I
I
II
I I I
I
/
I
rl I
I
I
rI
I I I
I
MAIN
STRUCTURE
I
r\
I
I I
I
I
(NJ 31.20' (OP-34)
33A5'
I
I
I
I
I
I
I
I
I
I
(S) 31.60' (DP-34 )
33.85'
MITERED END
SECTION
ADS HP STORM
"3""
OP-12
CF
(NE) 30.00' (DP-15)
DS-28
DS-39
DESCRIPTION
24"
DP-11
(NJ 30.50' (DP-14)
(E) 30,50' (DP· 13)
(SW) 30.50' (OP.15)
38.58'
MITERED END
SECTION
DP~
(S) 31.00' (DP-14)
(N) 31.00' {DP-27)
37.59'
SIZE
NO.
(E) 31 .00' (DP-12)
(S) 31.00' (DP-9)
(W) 31 .00' (DP- 13)
38.00'
FDOTTYPE C
INLET
PIPE
INVERTS
(W) 31,25' (DP.12)
(E) 31 .25' (DP· 11)
37.74'
FDOT TYPE E
INLET
DS-16
DS-27
TOP ELEV
TYPE
DRAINAGE PIPE TABLE
DP - .32 INV OUT: .34.50'
DP - .32 INV IN: .34.00'
DP - 33 INV OU T: 34.00'
DP - 1
DP
INV OU T: 31.00 '
12 27' .36" RCP @ 0 . ~3%-'
27f-- - - - - - - - - - - - - - f - - - - - - - - - - - - - - - f - - - - - - - - - - - - --f--f----=---==-::.c__:-=.c:_:c.:cc:___f---------------f---------------f-----------__J--BF-'-1-4f-28~"~-8""-"-.R.·BP--<>--+8.iElOC-------f----+27
27
DP-.32 25'
18" RCP @ 1.97%)
24 + - - - - - - - - - - - - - - -+-- - - - - - - - - - - - - - + - - - - - - - - - - - - - - -+-- - - - - - - - - - - - - - + - - - - - - - - - - - - - - -+-- - - - - - - - - - - - - -+-- - - - - - - - - - - - - -+-- - - - - - - - - - - - - -+-- - - - j - 24
24
24
8
m
0 + 00
~
LIFT STATION
SCALE: HOR.
V ER.
I
3 + 00
4 + 00
5 + 00
6+00
7 + 00
8 + 00
:~PARKAREA
~I
L___L_------ ~ --- ---- _gi ___
\ ~ \\
\
\
llmJI PROPOSED
¢>@
21
~
II
LOT52REARPROPERTY[JN_E_ _
-
-
11
\
\
R10'
I
\
\
SYMBOL LEGEND
::
a::I
DS-15
CASON DRIVE
1 " = 10'
1 "= 5'
II
151
\
1---------- 30" --------~
II
\
12' DBL GAT E
~~----*"--------·---~--L1-------l-----c/------~
·
R10'
\ o \
~c
'\\ \
~
\
@
~J--·4" F,,.'
!l
\
\
14"
\
~
i
~
4"MJDl45°BEN
\
\
\
\
~
\
I/--_,,
SS-11
FORCE MAN
'
V
I
I
"_(<;
I
10
I I I
I I
I
I
I ___,
JI
R10"'
,...-- ~
,..-----i:;:f=====~2~2~.======::::
~0 jl/02::::-, (
1:1
CONTOUR
I ' I
I
-----SP.11::::
~
::::::::::::-
~"fM----~·~1,1, . .~----·-~
-
-V.
. ;;
· ~
rn\___.-.+-r(~~~)LIGHT
35·
~-
0
~
~
::-{\
"""\._)
r
I! -
L
-F
' '-- 1-!I
-L
I
-
+--
-L
I
I
f--
-
--j -
_j
1" BFP RPZ
-
I
~1
I/
~
I I
I
r
1-
,_
I-
L
, 1
ir
,...,t-
I
I'
j_
1- .c___, I r r l
-r
r,_,
tf-----1-1
-,_j_
--,
- i1 _j_--J '
L---i_, _ -- J-.---1
t -+-I--,
--i- 1-
ABOVE GROUND FREEZE PROOF HOSE BIB
I-
,_ I
-r____j-
-,-
1 - - - - 10·
r
,_
_
-
- t-~
,. , _j
JJfl ___,,
=! j
-4=."=i l._-i -
d- I -J-
f-
SS-12
LIFT STAT ION
_jQ'
- -11---W-----
I'
_j_
J- S'
LIFT STATION SITE PLAN
~
PROPOSED WATE R METER
THIS SHEET
O-ti95
/1" PVC WATER SERVICE
/;
!!'!;
/J;/
\
\
~
R10'
'11 ----JjI I
PROPOSED VA LV E
[!§]
11
\ A"FM ____ ,.FM~~
\
I
' - -w--W - \W - - ' i -· -
---·~----·
r\
M
HA- "X" GEOTEC HANO AUG ER LOCATION
-II
'
~
f-----':-,-~'o-,- 212 - - - - t
PROPOSED MITERED END S ECTI ON
1-- - - -
11
'
j
(Q)
'--1--PROPOS ED CONTOUR
11
'
PROPOSED MAN HOLE
6' GREEN CHAINL NK FENCE
W ITH GREEN SLATS
11
INSTALL DROP
CURB ACROSS---.........
O OO
DRIVEWAY
PROPOS ED FI RE HYDRAN T
YARD CONSISTS OF 4 OF
#57 STONE OVER F LTER
FABRIC
fu11
\
DRAINAG E INLET
..§'I
'-1-- - EXISTI NG
-1- - - 5"
~II
8 + 27
SCALE: HOR. 1"= 40'
VER. 1 " = B'
II
~
·
w
2 + 00
95
0 + 00
j
1 + 00
11
I Ii I
I \ 11-J ij-1+-r--T-~
KEY MAP
~
Q
~
~
~
"1'i
REV
DATE
BY
R EV IS IONS
SCALE :
AS NOTE D
o - - - - + - - - - - - - 1 - - - + - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 0 1 - - -o_E_S_l_G_N_E_O_ B_Y_,_JH_s_____________--ll
aj
i:"
~
0----~------~--~--------------------------------0f-----------------------·
CASON DRIVE PLAN & PROFILE
ANDREWS PLANTATION SUBDIVISION
James H_Slanina, P_E_ 39197
James M_ Southall, P_E_39637
Christopher B_Forehand, P_E_58028
Stephen E. Price, PE_ 71646
Jeffrey c_ Petermann, P_E. 77540
S HEET NUMB ER
8
FOR SCALE VERIFICATION AFTER DUP LI CATION, THI S LI NE SHOU LD BE 1" LONG
I
_
-
Jir _
..
.
'~-;::-
,
8
I
'
I '
HA - 3
.. : r', -
'i'i-N.:
I
I
_]
I
J
SP-9
® ' - -HA- 8
/
1-- I
I
I
I
\
\
~
DS - 12
F OOT TYP E E IN LET
R IM · 37 74'
OP - 11 INV IN: 3 1.25'
DP - 12 INV OUT : 31.25'
~-
HA- 2
STA= 0 + 1~ _
EG EL = 38.7
ESHGW = 36.2
SS -1 0
SAN ITARY S EWER M H
.0
N
N
.,;
n
'~
I
~
w
39
36
--
go
f EXISTING GRADE
g~
42
II
-.0. 4A"""
i- -
-
-
/ R IM ; 38.83'
SP - 8 INV IN; 30.11 '
...1C - \:1
1 .~
vu T : ..JU . VU
/PROPOSED FI N ISH GRADE
4
-~
gg
+ ~
2~
II:>
Cjj'
~~
;5'. :'.J
~ w
39
39
36
36
- - - -· - -
II
r
SS - 5
SAN ITARY S EWER
R IM:
..
I
MH
INV IN:
INV IN:
,
'' -
11 ~:
28.80'
28.64'
~~·
SP - 10 INV OUT : 28.50'
-
_1-\-
.
--
- - -- - - -
9
D
33
·
30
SP - 9
·
~
~
n
24 + 00
33
30
30
SP
8"
273' 8" PVC Pipe @ 0.50%
'
..,m
..,'°
33
9
PVC Pipe
@ 0.§
~
v
..,'"'
12 27' 36"
@ 0 .93%
n
26 + 00
~
w
.; ,,;
w
.;
~ ~
25 + 00
~
~
"'
26 + 28
"'
0 + 00
DP - 8
- -
r:P- 8
OP - 7
R IM: 38.67:\
INV OUT : 34.70
--
-
--
ADS HP STORM @
-
~
1.133 1
,..,.... _ Q
0
N
·n
DS - 13
- -n~
~-~ -
<="
, · .,
-~
RCP
DP - 8
-
a
0 a
~ 0v
N
m
"'
1 + 00
R IM: 38.00'
DP - 12 INV IN: 31.00'
2 + 00
~
29'
18'~
RCP
0
~
SS - 8
SAN ITARY S EWER MH
INV IN: 34.50'
INV IN: 34.50'
, .,,,
) l lT·
SP - 7
..,, c,-,·
INV OU T: 32 .40'
_)
n
DS - 8
FOOT TYP E E IN LCT
OS - 7
FOO T TYP E E IN LET
( RIM: 39 .33 '
SP - 6 INV IN: 32.54'
--\--~
( "DP'"'- 6 39.62'
INV IN:
R IM: 39.59:\
INV OU T; 35.70'
DP - 6
OP - 7
\~
'3
M
..
· . -o
u
42
I
39
~
n
'..§.'.......+s..::....ADs......t-l
35.50'
INV OUT : 35.50'
~DP
-
6
e-Pipe @
29'
18" RCP @
0.70%
36
33
0.50-3
I
SP 7 393' 8" PVC Pipe @ 0.50%
OP
~ v
~
309
24'
273'
27
m
DS - 9
FOOT TYP E E IN LCT
EXISTING GRADE\
38.02'
SP - 4
SP - 9
DS - 10
F OOT TYP E E IN LET
R IM; 38.71 '
PROPOSED FINISH GRADE\
HA- 5
STA= 6 + 13
EG EL = 39.7 1
ESHGW = 37.7
"
30
0.70%_}
- --
a
N
ci
v 0v
ro
ro
ro
w
v a
· ..,
"'
.,; m
n
4 + 00
5 + 00
6 + 00
0
3 + 00
ro
m
.,; m
·
w
~
N
-·
~
N
.,; m
n
"' "'
7 + 00
"'
27
8+00
DP - 9 INV IN: 31.00'
DP - 13 INV OUT : 31.00'
DRAINAGE STRUCTURE TABLE
NO.
STRUCTURE
'"'
TOP ELEV
PIPE
INVERTS
DS-7
FOOT TYPE E
INLET
39.59'
(W) 35.70' (DP-6)
DS·8
FDOTTYPE E
INLET
39.62.'
(E} 35.50' (DP-6)
(NJ 35.50' (D P.7)
DS·9
FDOTTYPE E
INLET
38.67'
(W) 34.70' (DP-6)
FOOT TYPE E
INLET
38.71'
(E} 34.50' (DP-8)
(S) 34.50" (DP-7)
(N) 34 .50' (DP-9)
DS· 12
FDOTTYPE E
INLET
37.74'
(W) 31 .25' (DP-12)
(E) 31.25' (DP-11)
DS-13
FDOTTYPEE
INLET
38.00'
(E) 31.00' (DP-12)
(S} 31 .00' (DP-9)
(W)-31 .00' (DP-13)
OS-45
FDOTTYPEC
INLET
35.97'
(E) 33.00' (DP-37)
DS-10
DRAINAGE PIPE TABLE
NO.
SIZE
DESCRIPTION
"
SLOPE
INVERTS
'tV
:1
DP~
'8'
Ree
29'
0.70°4
DP-7
,..
DS-7" 35 .70'
DS-8" 35 .50'
ADS HP STORM
275'
0.36%
DS-8 = 35 .50'
DS-10 = 34.50'
OP~
,..
RCe
29'
0.70°4
DS-9" 34 .70'
DS-10 = 34 .50'
DP~
2'"
ADS HP STORM
309'
1.13%
DS.10 = 34.50'
DS-13 = 31.00'
DP·1 1
,..
ADS HP STORM
147"
0.34%
DP-1 2
,...
DS-11 =31 .75'
DS-12 : 31 .25'
Ree
2T
0.93%
DS.12=31.25'
DS.13=1!1.00'
DP·1 3
'2"
ADS HP STORM
139"
0.36%
DS-13-31 .00'
DS-15" 30 .50'
DP-37
,..
ADS HP STORM
282'
0.35%
DS-45 = 33.00'
DS-46 = 32 .00'
I
I
I
~
CALEIGH CIRCLE
-'F
_,
r11lll ,,-o,
.- .. ' ';t ' · .1';. : ~ ' ,._
-~
-..,
--,.. ~,.:
_
'"'4- - - - -
I
( I!/
"'~'.,. ·. ·
0\_L_,
~.
'-"- -
~Ii
·'
Ir'"
",
;
. · -.· ·.·
ii
.
:·_~.:!,-
I
..., fi25· - - - - 1- - - - - - - 1 - - - - - - -+ - - - - - - - i- - -...__
SANITARY SEWER STRUCTURE TABLE
NO .
SS-1
sso
STRUCTURE
"'"
SANITARY
SEWERMH
SANITARY
SEWERMH
38.02'
NO.
SIZE
SM
,.
8" PVC Pipe
S"
8" PVC Pipe
S"
8" PVC Pipe
DESCRIPTION
"
,,,.
SLOPE
INVERTS
0.50%
SS-1 -= 35.00'
SS-2" 33.24'
0.50%
SS-3 = 30.40"
SS-6 -= 28.80'
0.50%
SS--&= 35.71"
SS-7 = 34.43"
0.5\)%
SS-7 = 34 .34'
ss..s = 32 .54'
(N} 35.00' (SP-1 )
(E) 28.80" (SP-4 )
(N} 28.B4' (SP-9)
{W) 28.50" (SP· 10)
(SJ 30.44' (SP-7)
SM
SM
320"
'"'
I
H
(W) 35 .71" (SP-5)
Sf>-6
8'
8" PVC Pipe
,,,.
40.21"
(E) 34 .43" (SP-6)
(N} 34.34' (SP-6)
SP-7
8"
8" PVC Pipe
393"
0.50%
SS.S = 32 .40"
SS-6 = 30.44"
SANITARY
SEWERMH
39.33"
(S) 32 .54' (SP-6)
(N} 32.40' (S P-7)
Sf>-8
8"
8" PVC Pipe
278'
0.50%
SS-9 = 31.50'
SS-10 =30.11'
SANITARY
SEWERMH
38.83'
SANITARY
SEWERMH
SS-'
SANITARY
SEWERMH
SS-10
40.18'
PIPE
INVERTS
40.66'
SS<
SS-8
TOP ELE.V
/
SANITARY SEWER PIPE TABLE
{E) 30.11' (SP.S)
(S) 30.00' (SP-9)
SM
8"
8" PVC Pipe
SP· 10
8"
8" PVC Pipe
- - - - - 1 -...
I
I
I
®
I
I
I
I
I
I
I
-,,
@
I
I
I
I
I
I
' -..l
@
!' ,
I
I
I
-81
',...__
- -
I
I
I
@
,
- - - ........
j
A
QJ
QJ
.!:::
SYMBOL LEGEND
-..
I
I
I
I
I
I
I
G3'
""'
I
I
I
I
. .__
''
;
'I, '
'
PROPOS ED DRAINAGE IN LET
~
PROPOSED FI RE HYDRANT
w
_J
~
PROPOSED MAN HO LE
LL
(Q}
PROPOSE D MITER ED END S ECTI ON
....
PROPOS ED VA LV E
~
PROPOS ED WATE R M ETER
'- -
I
I
I
HA-7
~
A
I
"
I
'
......._
(/)
ll!llJI
-
0
0::
CL
- EX ISTI NG CONTOUR
PROPOS ED CON TOUR
HA - "X " G EOTE C HANO AUG ER LOCATI ON
""z
::5
CL
w
_J
I
I
(.)
0::
!
(.)
I
(9
273'
0.50%
ss. 10 = 30 .00·
SS.S = 28.64"
"'
0.50%
SS-5" 28.50'
SS-11 :27.60'
go
. 0
iil a
SS - 7
SAN ITARY S EWER M H
R IM: 40.21 '
SP - 5 INV IN: 34.43'
SP - 6 INV OU T: 34.34'
42
/PROPOSED FINISH GRADE
+~
'r ~
{EXISTING GRADE
;5'. :'.J
~ w
I
I
- 0.143
I
39
36
I
,,
<
·-6' B"
-
PVC Pii:;i:e @
-
-
<>::
(.)
w
_J
42
-0, 15%
- -
w
_J
SS - 6
_SAN ITARY ~ EWE R MH
R IM: 40.66
SP - 5 INV OUT: 3 5.7 1 '
-
--
~
--
--
-
LL
39
0
0::
0 . 503
CL
36
""z
33
::5
CL
TH IS SH E ET--<~
30
27
30
-..,
,,;
· v
·n ..,m
N
"
·"n
N
~
~
m
"'
w
_J
-I'
n
w
,,;
(.)
0::
"'
1-~~.-~~~~~..~~..~~~~~~~~~~~~~~~~~~~~~~~~~~~~...~~~~~~~~~~~~~~~~~~~~......~~~~~~~~~~~~~~~~~~~~~~~~~..~~~~~~~~~~~~~~~~8~+~0~0:..~~~~~~~~~~~~9~+~0~0~~~~~~~~~~~~'~0~+~0~0~~~~~~~~~~~..:'~':+~o~o~~~~~. .~~~~~~~~~~~~~~~~~~~~.....:K~E~Y~M~A~P;..~~~~~~~~~..I~
REV
DATE
BY
SCALE :-
R EV IS IONS
R~:::~ ::
D ES IGN ED
BY:
AS
NOTE D
J HS
:: :
.::PANHANDLE
ENGINEERING, INC,
(!)
James H. Slanina. P.E. 39197
cALEIGH c1RcLE PLAN & PROFILE
ANDREWS PLANTATION SUBDIVISION
~~=:·:~:;:~;~:::r""''
"'meyc.eeSHEET NUMBER
9
57916 B
PROJ EC T NUMBE R
i:'
~
~
a
ISSU E DATE:
MAY 2017
0----~------~--~--------------------------------.lf-----------------------·
NOT
R ELEAS ED
F OR CONST RUCTI ON
BY:
DATE :
ACAD
FILE NAM E :
579 1 6 - Be 1. dwg
ENVIRONMENTALENGINEERS · CMLENGINEERS . LANDPLANNERS
;3005 South Hig hway 77 Lynn Haven , Flo rida 32444
(850) 763-5200
Fax (850)769-0730
pe@panhandleengineering.com
LYNN HAVEN FLORIDA
1
DPR C ERTIFI CATI ON # EB - 7806
-
~
~
JJ
°'~
f'--
"""'. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . L!)
@PANHANDLE ENGINEERJNG. INC. ALL RtGHTS RESERVED. NO PART OF THIS DOCUMENT MAY BE REPRODUCED OR UTILIZED IN #N FORM WITHOUT PRIOR WRITTEN Al.JlljORIZATION OF PANHANDLE ENGINEERJNG. INC.
FOR SCALE VERIFICATION AFTER DUP LI CATION, THI S LI NE SHOU LD BE 1" LONG
SCALE: 1" = 40'
,, /
®
ll =22:i/
l
I/
I
'
-
I
I
"'
.
-·
-;·: ,,,,.
-
~
...
· ,· "<
DP-4
I
I
1)
'
Ds - 2
SS-1
SAN ITARY SEWER MH
RIM· 40 18 '
.
.
FOOT TYPE E INLET
HA-6
STA= 12+ 89
EG EL= 39.r"'
ESHGW = J7.5
RIM: 39.56'
DP- 1 INV IN : 36.50 '
DP- 2 INV OUT: 36.50'
SS - 2
SAN ITARY SEWER MH
,
RIM: 39.33,\
SP- 1 INV IN: 33 · 24
DS- 4
PROPOSED FINISH GRADE\
FOOT TYP E E INLET
RIM: 38.65 '
DP- 3 INV IN: 34.50' 1
EXISTINGGRADE\
SS - 3
SAN ITARY SEWER MH
'
RIM: 38.00
SP - 2 INV IN: 31.14:\
SP - 3 INV IN: 30.50'
Ds - 5
FOOT TYPE E INLET
o
dg
'° o
DS - 3
.-R IM: 37.62'
/
DP -1 9 INV IN: 32.50'
DP - 5 INV OUT· 32 50'
DS - 6
FOOT TYPE E INLET
RIM· 37 55'
.
.
,
DP- 5 INV IN: 32 .25,
DP- 4 INV IN: 32 · 25
HA- 4
STA= 20+ 54
/ EG EL = 35.0
ESHGW = 33.0
42 ~-+--S~P'=il~l~N~V_O\l\!UTi'-"3~5~.D&O~'---~----_:__:__ _:__:__--''c-,-.-_~---j'---=---'::...::c.:_...::.::_:...::.::.:::.::__--'"'-"'--""l"-01J"'~3c-l.4"~'--\---------rn,,c_c-7L,;.;,
....~,;.;.
, N ,~-u;v··~-vm..v'_\'~--r-l'l""Tl'""''--'"'--ll'l!J+----------~-------+--\--~ScP=-~4_,,,1N~V'-'iO~U~T~,~3~0~.4~0~'--1----o+i>11!i~c--f-----~l -/·
_ _- ,,._,__ _ __,,,'°'"'--""~-"'"'"JL_
"·~'-"'~''----~s°'S~4~--f-----,o>i-42
~t.--:::::--:::::,,.,:::::==::::--:==::::=1-======:==:::==::::=~~,,.,
39 j
-0. 3%
f
u" ---- r-1pe@ 0 .50%
DP 1 27' 18" RCP @ 0 .37%
DP - 4 INV OUT: 34.50 '
=::::::::::E~-~,~~~5§:::!~~
-----
---1-----3
36
-------1·-
____
\=-=-,,,,,'."'~~""'O:::""=::"""""""""=='"l'~;o;;o;~~=-~'\C'...,,:-"~~~..;..i.~----..:..__:..:..:.:._~..:,"'.. ~...D=P~-=3r:IN~V:::O~U:T~'~3~4~7~5~·~""'""''"'""""'""'""'i::::;:::::;;::~::::~=l:::::l::::::::::::::::=t::::::::::::::::l,:_".,~"~~'.';;;t::::::::::;:/7r------------~--,;;;:::t;NV-;;oiu·
£
~~~~·"
·u
I
I
·~ ~~~~~~~~=======~====::::::
:
UFOOT1YPE E
DS1
INLET
.... ,
OP 3 2-7' 18" -RCP
-@
SA ITARY SEWER MH
r---- - -
..-
30-1----------------1---------------1---=)>~: ~9-J>4-'..-----
DP-1
158 63
· '
RIM:
SP
0 .93%-
2 400'
-
...
~~..,
1-1
L"t'
" '
-
_ _ _
-1
/
l. 2 0% SP
/ -
INV
ci
g
~1 ~g
~£
OUT: 31.50'
~
=====t==============i~~~~~---1--1--------i
F-=-
..:i10KM@ 0.76%
8" PVC Pipe @ 0.50%
_
I-
.. 6
TI
~-
~200' a~ P\LC____fl""''~®~O~-~s~o~
·~l-----------------c 30
INV OUT: 36.60'
27 f---------------+---------------+---------------+---------------+---------------+---------------+---------------+------------"--91'-'~'""'"'~~
...~.-Rf'-<>--"""
""'!--------+----------------t 21
~~
r:::I=::
~~
~~
~;;;
~~
~~
~~
~W
~ ~
mW
~ ~
~~
11 + 00
12+ 00
13+ 00
14+ 00
15+ 00
16+ 00
17+ 00
18+ 00
19+ 00
20 + 00
21 + 00
~ ~
DRAINAGE STRUCTURE TABLE
NO.
STRUCTURE
TYPE
TOP ELEV
PIPE
INVERTS
DS-1
FDOTTYPE E
INLET
39.54'
{W) 36 .60' {DP.1)
DS-2
FDOTTYPE E
INLET
39.56'
(El 36 .50' (OP-1)
(N) 36.50' (DP-2)
DS-3
FDOT TYPE E
INLET
38.63'
(W) 34 .75' (DP-3)
OS4
FDOTTYPE E
INLET
38.65'
(E) 34 .50' (DP-3)
(SJ 34.50' (DP· 2)
(N) 34 .50' (DP-4}
DS-5
FOOT TYPE E
INLET
37.62'
{W} 32 .50' (DP-5)
(E) 32 .50' (DP-19)
DS-6
FOOT TYPE E
INLET
37.55'
(E) 32 .25' (DP-5)
(S) 32 .25' (DP-4)
(W) 32.25' (OP-10)
DS-29
FOOT TYPE C
INLET
36.35'
(S) 32.00' (DP- 26)
DS-32
FOOT TYPE C
INLET
36.90'
(S) 32 .00' (DP.28)
(E) 32 ,00' (DP.29)
DS-33
FDOTTYPE E
INLET
08-3<
FOOT TYPE E
INLET
DS-35
DS-45
PIPE END
FOOT TYPE C
INLET
INVERTS
,,.
0.37%
DS-1 = 36.60'
OS-2" 36.50'
AOS HP STORM
275'
0.73%
Ds-2 = 36.50'
DS-4 = 34.50'
18"
RCC
,,.
0.93%
OS-3 = 34.75'
OS-4 = 34.50'
OP-4
24"
AOS HP STORM
295'
0.76%
DS-4" 34,50'
OS-6 = 32.25'
DP·5
24"
RCP
27'
0.93%
OS-5 = 32.50'
OS-6 = 32.25'
DP-1 0
30"
AOS HP STORM
i47'
0.34%
DS-6 = 32.25'
DS-11 =31,75'
DP-19
24"
ADS HP STORM
147'
0.34%
OS-20 = 33.00'
08-5 = 32.50'
DP-26
18"
AOS HPSTORM
265'
0.19%
DS-29 = 32.00'
DS-30 = 31 .50'
DP-28
18"
ADS HP STORM
72'
1.38%
OS-31 = 33,00'
OS-32 = 32.00'
DP-29
18"
ADS HP STORM
142'
1.06°A.
DS-32 = 32.00'
DS-33 = 30.50'
DP-30
18"
RCP
26'
1.92%
DS-33 = 30.50'
D&-34 = 30,00'
DP-31
24"
AOS HP STORM
58'
1.72%
(SW) 29.00' (DP-31)
OS-34 = 30.00'
OS-35 = 29.00'
(E) 33 .00' (DP-37)
0.35%
DS-45 = 33.00'
OS-46 = 32 .00'
6.15%
OS-46 = 32.00'
OS-47 = 29.00'
34.87'
34.68'
(SW) 30.00' (DP-30)
(NE) 30 .00' (DP.31)
35.97'
OS-46
FOOT TYPE C
INLET
35.34'
(W) 32.ocr (OP-37)
{SE) 32.00' (OP-38)
OS-47
PIPE END
30.64'
(NW) 29,00' (DP-38)
~ ~
~ ~
~ ~
~ ~
~. ~
~ ~
~ ~
DRAINAGE PIPE TABLE
SLOP E
(W) 30.50' (O P-29)
(NE) 30 .50' (DP-30)
31. 18'
~ ~
NO.
SIZE
DP·1
18"
RCP
DP-2
18"
OP-3
DP-37
DP-38
18"
18"
DESCRIPTION
ADS HP STORM
ADSHPSTORM
282'
49'
·
11 .3'±(VARIES
ALONG LENGTH)
,J
l
...,. '
~
l~I PROPOSED DRAINAGE INLET
-
~ PROPOS ED FI RE HYDRANT
~.~
'
11
I
i> I
'
NO .
SS-3
''"'
SS-0
SS-9
STRUCTURE
TYPE
TOP ELEV
NO.
SP-1
SANITARY
SEWER MH
40.18'
SANITARY
SEWER MH
39.33'
SANITARY
SEWERMH
PIPE
INVERTS
8"
DESCRIPTION
8" PVC Pipe
352'
SLOPE
INVERTS
0.50%
SS-1 : 35.00'
SS-2 = 33.24'
(N) 35.00' (SP-1)
(S) 33,24' (SP· 1)
(N) 33.14' {SP.2)
(S) 31.14' (SP-2)
38.00'
SIZE
SP-2
8"
8" PVC Pipe
400'
0.50%
SP..J
8"
8" PVC Pipe
200'
0.50%
SS-4 "" 31 .50'
SS-3: 30.50'
SP-4
8'
8" PVC Pipe
320'
0.50%
SS-3: 30.40'
SS-5"' 20 .80'
SP-5
8"
B" PVC Pips
256'
0.50%
SS-6:35.71 '
SS-7 "" 34.43'
SP-8
8"
8" PVC Pipe
278'
0.50%
SS-9 = 31.50'
SS-1 0 = 30.11'
33
ss-1 o = w.oo·
SS-5 = 28 .64'
~
(W) 30.40' (SP-4)
(N) 30.50' (SP.3)
SANITARY
SEWER MH
35.60'
(S) 31 .50' (SP-3)
SANITARY
SEWER MH
40.66'
(W) 35.71' (SP-5)
SANITARY
SEWER MH
35.70'
(W) 31 .50' (SP-8)
SANITARY
SEWER MH
38.83'
(E) 30.11' (SP-8)
(S) 30.00' (SP-9)
SP..Q
8"
8" PVC Pfpe
273'
0.50%
M
PROPOS ED VALVE
CL
PROPOSED CONTOUR
HA- "X" GEOTEC HAND AUG ER LOCATION
" -
SAN ITARY SEWER MH
DP- 29 INV OUT: 32.00'
0::
I
SHEET~
~
I
~0
.;j.: ~
"-EXISTING GRADE
- - - - r - - - - - - - - - - - - - -c 33
- - -
SP 8 278' ·8" PVC Pipe @ 0.50%
-r
....J
LL
-I
0::
-- -
'~ ~
21 + 00
~
v''-DP - 30 26' 18" RCP@ 1.92% CC! CC!
23 + 00
- -- --
""z
~
~l~:J =
I I Ii-' , ,
"! O!
w w
/
24+ 00
KEY MAP
~
22 + 00
~
0
CL
- -jf fl- +--
30
27 -t----t- - - - - - - - - - - - - r - - - - - - - - - - - - - - r - - - - - - - - - - - - - - - - j - 27
oD
UJ
UJ
ci
:~~~~~~~~~~,,~..·~·~o"~A~O~S~H~P~S~T~O~R~M~@~1~.D~6~3~,~~~~~~~~P~R~O~P~O~S~E~D~F~-IN~IS~H~G~RA~D~E~~~~t
~
l9
S=P---8,,,,,IN~V+O:U:T'==3=1=.5:0:'==':·:':':3="";;J~~~=1-'\_~-~--'<------------e 36
30:~"e~~t::::;;;~/~~'lfi/;:,_-:=
E~
~
\
I
u
3g!~·"~--t------;T~-7r-'--",'' "~~B3x5~7~0J·1 ;)Ui:;:;;-:;;Q'---::;~~==~l:.:_:_=::.=~:;::::::::::::=:=:;:;;:;:;;:;:;;:;:;;~~~~ 39
1.r
u
....J
8 NN
~
::5
CL
u
4- a,-i--t--------7'--<'0-a--,--------------+-iig g.
""z
UJ
111
DS - 32
FOOT TYPE C INLET
~R I M : 36.90'
0::
....J
DS- 33
FOOT TYPE E INLET
DP - 30 INV IN: 30.00~'iRIM: 34.87'
DP - 31 INV OUT: 30.00'
DP - 29 INV IN: 30.50'
OP - 30 INV OUT: 30.50'
SS-2=o33,14'
SS-3=31 .14'
0
'...\-""-
THIS
DS- 34
FOOT TYP E E INLET
-RIM: 34.68'
PROPOS ED MITERED END SECTI ON
I
I
SANITARY SEWER PIPE TABLE
(Q}
I
'
UJ
....J
LL
PROPOS ED MAN HOLE
-.......-%'.;-- - EXISTI NG CONTOUR
DS-29
(/)
~
~ PROPOSED WATER METER
I
-- !
SANITARY SEWER STRUCTURE. TABLE
QJ
QJ
.!:::
SYMBOL I FGEND
::5
CL
UJ
....J
u
0::
~
u
. . . . . . . . . . . . . . . . . . ..,.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .,... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .,... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .,... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . I
James H _Slanina, P_E_39197
(!)
SCA LE ~ AS NOTED
DATE
REV
BY
REVISIONS
SHEET NUMBER
DESIGN ED BY: JHS
::
R~:::~ ~::
.::PANHANDLE
ENGINEERING, INC.
cALEIGH c1RcLE PLAN & PROFILE
ANDREWS PLANTATION SUBDIVISION
~~=:·:~:;:~;~:::r""''
"'~"'""~'""'''"'°
~
10
57916 B
PROJ ECT NUMBER
;:~
~
0
ISSU E DATE:
MAY 2017
0----~------~--~-------------------------------ll------------------------·
NOT
RELEAS EO FOR CONSTRUCTION
BY:
DATE :
ACAD FILE NAM E:
579 16 - Be 1.dwg
ENVIRONMENTALENGINEERS · CMLENGINEERS .
LANDPLANNERS
;3005 South Hig hway 77 Lynn Haven, Florida 32444
(850)763-5200 Fax (850)769-0730 pe@panhandleengineering.com
LYNN HAVEN 1 FLORIDA
DPR CERTIFI CATION # EB- 7806
-
1!!'--.
.................................................................................................................................-.-.-.-.-.-.-.. .-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.. .-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.-.......-.-.-.-.....-.-.-.-.-.-.-.-.-.-.. .-.-.-.-.-.-.-.-.-.-....
@PANHANDLE ENGINEERJNG, INC. ALL RtGHTS RESERVED_ NO PART OF THIS OOCUMENTMAY BE REPRODUCED OR UTILIZED IN #N FORM WITHOUT PRIOR WRITTEN AlJTI10RIZATION OF PANHANDLE ENGINEERJNG, INC_
~
JJ
°'~
f'--
L!)
FOR SCALE VERIFICAT ION AFTER DUPLICATION, THIS LINE S HOU LD BE 1" LONG
'
~g
ala
+~
Oaj
~q
'.:;~
I/~ :'~.J
>'j
/STORMWATER SWALE TOB
rSTORMWATERSWALE FLOWLINE
<:'.J
Vlw
-0.31%
0
C!o
~g
+ a:i
N n
!EXIST. GRADE'
,!t[;"i
11
N
q o
:fl~
II
~=:;~.,_;;::~~~~~:;.:=_.;;;;:;;;;=::.;;.;~:;.:3.:;;:;;;;::~~;:~-::'~0~·:1·~%~'.:'.-'.::-'.:J:;::;::~~~~~~~~~~~~~~~~~~~~~~..;_~~~~~~~~~~~~~,i!2-~-~~~~~~~~'~'~~~==.::=.::::=.:::.:::~~~==:_:~~w~:;;;..:~'~~.:;;~.:;;~'
,:;;:..:::;::..:~~;_;:::::i?.!v.~·:=:::i::::::::::::::::::::::::::::::i:::::~et~~~::================i=============================i========================;·"t~r,===f=====t39
~
!-------------~--,-.....83,,
~~
t=:;_~_::_:=:::==~
39
;tll
~g
gq
°'+ ~I
. 'o ---z77
-
1o
'I'-'"'"'
',,_,_. ·"
19'
------------1--~~~~~~=~~=~~-.~~ft=-====-==-====·=*~===1--------------=~--~~---------~-~
·~~
4~~-----~-----=~-~o~
.2~1·"===~=========~~~·-+--+3·
DP 17 3JO ' 18" ADS HP STORM
0. 15%
-~
r-
Q
U . · U/·
-----
f-~~t-~~~~"'
~'c4D~_SIG+_~------C-Wb"'1'-f~~~~~~~~~~~~~~--j~~~~~~-fE~·f---1¥~;;::,_~v~v~i'£_·v-:;_~::::::::::::::::::::::::::::::::::::::::::::::::::::::::t=:::::::::::::::::::::::::::::::::-::::::::::::f=:::::::::::::::::::::::::::::::::;;;;;:;~;:::;i;~~ll·~::;:/~~-=-=-===-==========i==:::...,:-·~·:;··'==:;,
· v~'~vv~==-v::::···~:.
.... ~~~V~.::':vv~oo~~.::=-::::::::::::::;;;::::;;~~ ~~~~~~~~-~~~---j
- ~~~~~~----~--~~~--~~~-~==1-~~~~----~
~~--~-~~--~-~~+-~~-+ 33
'
RIM: 38.33
,
DP -1 6 INV OUT: 35. 0
·_j
RIM : 37 .83'
DP-16 INV IN : 34.50'
' --
~
I
1·~~
[_
I
DS 20
FOOT lYPE E INLET
·
/
RIM: 3 .33'-../
-- · - ··.. '"'· - -
I
-
-
- r- ----
f-~~o-+W~~~~~~-"'---'-=-'-"---"._:'.C'--"._:'.,'-fw'-~~~~~~~~~~~~~,-+~~~~~,D"P~1~7f'ilN~VC'-':o"u~T~,~3~4~.~5*o·~-+o~~~~~~~~~~~~~~"-+~~~~~~~~~~~~~~~o-+O~~~~~~~-D~P~-~,~.lL,N~V1'1ll0-U~TL,~~'+."'10ll'~~~~~~~~~~~~~"-+o~~~~~~~~~~~~~~ro-+oo~~~~~~D-P--~,.~l-NV-RllMN~,~3h3~0~0~N-+0~~~~~~~~~~~~~~ro-+m~~~~~~~~~~~~~~N-+~~~~~~~~~~~~~~~N-+~~-N+3o
"'!
q
.
°'
r"'lf"l
0+00
.3+00
Oo
Oo
oo
w .
+~
">
~ f"l
r"'lf"l
r-- co
r"'lf"l
5+00
6+00
7+00:
8+00
-~ ~/
"
,.
-- ----- ·- -- - --- - ·..
-
-
I
;:TORMWATER SWALE TOB
STORMWATER SWALE FLOWLINE
DS-21
FOOT lYPE
+~
------=0.6--1--%-
39
r-- co
~
c
- -
--
L _
--
-
--
- -
--
J}.j-1-
-
--
DS-11
FOOT lYPE E INLET
RIM : 36.33'
DP-10 INV IN : 31.75:\
.. .
.. . .. ...
DP 11 INV' OUT: 31.75'
~
-'
ci
-- ----- - - -- - - - - ·- -- -· - - - - -- ---- - - ---- - - OP 20 275'
1'8~
I
ADS HP STD-RM
rn
N n
0
0
·
·
0+00
m
r"'lr<)
·
~
q
DP- 19 INV OUT: 33.00Y-i
co
"lr<)
11 +00
i 2+00
"! CO
'!..
~
. ,,.,
,,..,
~ iri
r·n
13 + 00
14+00
r":
-r"'l
"'!
;;:;
,,
15+00 15+21.89
rn
n
1 +00
· -
~
ro ro
ci ,,;
-· n
ci ro
·ci
2 +00
3+00
4+00
-n
~
n
N
ITT
·
Oo
oo
42
., 0
\ 1~
n
21 :t95
1v
OUu
H-
D"M
n
36
u.1670
N w
0
5+00
6+00
7+00
5+00
6+00
7+00
~
n
"'
m
n
~
n
~
~
n
30
-n
· "n
ro
,,;
"m
,,;
@
[i)39
m
0.36%
@
"'
0
0
ci
ti:
10+00
\~
0.34%
33
·
"mn
r..... 0
,..: m
"lr<)
9+00
/EXIST8_ ~DE DS-22
oo
FOOT lYPE E INLET
·,,;
RIM: 37.33'
DP 20 INV IN: 4.00'
1- - --;<"
BP-------21-----JMI QY+; 34.00·
INLET'
_J)P-2()_ IN'IL.OUT ~~ . ()G.'..._
36
30
~ 0r..: m
r"'ln
N
SOUTHEAST STORMWATER SWALE EASEMENT
Oo
Oo
oo
o·
-< w
4 ... w
r"'l \/")
co
''$!'f"l
IX>
4+00
I
0"
co
r"'lf"l
r": ...,
CC!
a:i co
"lf"l
IX>
N
w
·
"'
~
n
7+35. 10
SOUTH CENTER STORMWATER SWALE EASEMENT
0+00
1 +00
2+00
3+00
4+00
8+00
9+00
10+00
11 +00 11 +03.49
SOUTHWEST STORMWATER SWALE EASEMENT
05-1 5
FOOT lYPE E INLET WITH 6 . ROUND BOTIOM
RIM :
DP-14 INV IN:
DP-13 INV IN :
OP- 15 INV OUT:
DS-13
FOOT TYPE E INLET
RIM : 38.00'
OP-12 INV IN : 31.00:\
OP-9 INV IN : 31.00'
DP-1 3 INV OUT: 31.00'
38.01 :'\
30.50'
30.50'
30.50'
.--DP-12 27
36 RCP @ 0.93%
DS-12
FOOT lYPE E INLET
;:RIM: 37.74'
DP-11 INV IN; 31 .25'
OP - 12 INV OUT: 31.25'
05-11
FDOT TYPE E INLET
~ORPIM_, 3D6. 3N3V' IN'
. ,
31 75
DP-21 INV IN; .31 .75'
DP-11 INV OUT: 31.7 5 '
DS- 6
FOOT TYP E E INLET
RIM : 37.55'
DP-5 INV IN : 32.25'OP-4 INV IN: 32.25'
OP-10 INV OUT: 32 ,25'
1 1
__
..-QP-5 27' 24" RCP @ 0.93%
DS-20
DS-5
FOOT TYPE E' INLET
FOOT lYPE E INLET
RIM : 37.33'..-R IM : 37.62'
DP-18 INV IN: 33.00'
1
DP-19 INV IN: 32 .50
OP-19 INV OUT: 33.00'
DP-5 INV OUT: 32.50'
I
;;I
39i===-:==--=~=t~==-~=-==t--=~~;:::::::::::::::::::~-=="'f"~o=--==="--=~~\
- ;;;;:::::;:t:.~-=t="1"-;t--~~~~~~~~~~~~=-r-c-===--===-===~-+~
=-:::::::--=::::"-=::~~~=::1::.:::.:i,.:=tti-:t~~~-=--=-~~~~--11 -----~139
je&-NEN'f--7/L__++- f+- - f - -
\
36
P OL EL = 34.4'/
-
-
_
36
-
;+=~~~~-;:;;:-;;Ftis=;;it;;;;;;;;:t-e::ii;<'
0
11
3
1
·~·
~~"
HP STORM
..........
0.34%
@
""" . 10 147' 3 "ADS HP STORM
@
DP-19 147
0.343
3
24" ADS HP SlfDRM
@
0.343
33 1~~~~~1~0:':'"~~~~~~~6RM~~~~~~~~O~P~1~o~·~v,~~-·~""~-~~~-·~·~@~0~.~B~%~~~~~~~1- ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~-~~]1~~~~~!SS~~~~~~~~~~~~~~~~~~1
3o -l---1'vl ----+-l._-_...+-l1=
=F==-1
1
27
q §;
~
0+00
33' 8" PVC Pipe
@
_
-10 179 a ~ PVC Pipe.'@ 0.503
4:
~
NITARY SEWER MH
IM: 38.50'
-10 INV IN: 27.60'
l'.¥'®12 INV IN: 28.00
SP-1 t INV OUT: 27 .50'
vN'
0.5 i-
~q
+~
28.64'
30.44'
28.50'
1~
N
w
-0.91%
3+00
42
1 . 53
39
DS-.32
FOOT lYPE C INLET
f 3 _,.,....,-R IM : 36.90'
36t-- - - - - - - - - - - - - + - -- - --B6--o-l-'- - 6
DOT TYPE C INLET____
DP-28 INV IN: 32,00'
RIM: 36.35
;~;1~~~:::::::1 33
DP-29 IN V OUT : 32.00'
33+------------~~m.-~~~~~,,,.-~-ur
.o l1~v vu T; .J.J.uu OP 28 l ·
_,
2 18~ A1S HP
- - - STORM @ 1 38%
30 + - - - - - - - - - - - - - - + - - - - - - - - - - - - - - f - - ' - - - - - - - + 30
ro
~ g
N
,,;
v
·
:;;
~
g. 00
g0
~
1+00
2+00
r"'l
4+00
5+00
/f
r"'l
""
30
NW DRAINAGE EASEMENT
1 A'
1iJ
Q)
SP-3 INV IN: 30.50 '
SP- 4 INV OUT; 30.40'
.s::::
(/)
6+00
7+00
7 +61 .39
(/)
1-
36
.!l:~/
~~
1--
:::?
w
~
-
,/
I
"·
FOOT-"lYP
-0.52%
-
"
--
-
'"
TORM
@
0. 93ro
"·
o+oo
N
w
w
,.:
n"
--·
z
".
0
~ 36
1 +00
2+00
~
n
0::
,_
0. 19%
~
"n
~
@
·
,,;
~
2+47.43
'··.
-
('.)
DS-29
INLET
.!l: G'i
IM: 36 .35 I VI
c
I
..
w
Oo
Oo
-o +
+ r"'l 11
-
I
w
m
OP 26 265' 18" ADS HP- STORM
30
z
w
P~27
·
"n
ro
N
~
n
3-tOO
w
i
30
·n· 8
" ::l
:::?
0::
0
Jt47.19
1-
NORTHWEST STORMWATER SWALE EASEMENT
NORTH CENTER STORMWATER SWALE EASEMENT
(/)
Oo
(/)
00
.
+n
~q
1-
"
w
z
+~
0
II£
~w
~
.!l: G'i
--
DS-_'!:_5
FD T lYPE C INLET
RIM : 35.97'
OP-37 INV OUT: 33.00'
OP JI 282' 1a·" A
./
s
HP STORM
@
- - --
0.35%
DS 46
INL-ET
FOOT lYPE
RIM 35.34'_/
DP - 37 INV IN] 32.00'
30
27
-
P---=-3-a-----mv---ett~.;.'
DP- 38 49' 18" ADS H
25
0
~ 0
ro
~
,,;
ro w
~
~ ,,;
1 +00
2 +00
n
·
~
~
n
n
0+00
~
n
n
n
:::?
~w
-0.22%
- -
-
"n
OS- 14
FOOT lYPE C INLET
RIM 37 59'
INV IN: 31.00'
DP-14 INV OUT: 31.00'
Do
DS-30
Oo
oo
FOOT lYPE c INLET ~~
.
.
DP 26 INV IN : 31.50' .lJ: "
~
DP 27 INV OUT: 31 .50i w
0.83%
0.643
I
~
36
~
al
..,
n
0+00
RIM : 38.00 '
"'
,~ . .
WEST TO EAST ACROSS PROJECT STORMWATER SWALE EASEMENT
11
_J
..
\_i~'"""" '' ~~ ~·
0 · 50 ·~·
a:i
go
. 0
NO
-,,;
o~"~"c::=:=:=:=;:::=:=:::ii<~wOJ::::=:=:=:=i=::=:=:=:=:=:=:=:=:==~3~
~
~.. ji:j:":=:=:=i=::=:=::J~"fc't:::=+ 39
w
~
~~
+ ~
@
~
~m
~q
~~
38 .02
,
~
Oro
~~
+~
SP 4 320' 8" PVC Pipe
SEWE~S M~
RIM:
" .
2 +00
SP-9 INV IN:
SP-7 INV IN:
SP-10 INV OUT:
~g
gq
SANITARY
~
SS-12
SANITARY SEWER MH_
RIM: 39.00'
SP-11 INV IN: 27.33'
~g
O+OO
;; nn
rn
rn
STORM
--
,,;
.; w
3+00
4+00
~
n
n
n
@
1--
/
- \.
'----..;
I
~
33
w
·"'-,
~
~
30
'
z
27
-
N
,;
n
~
-.. 5
\
5 .15%_/
~
w
36
0
0::
n
rn
N
n
w
5+00 5+ 10
STORMWATER DRAINAGE EASEMENT KEYSHEET
NORTH STORMWATER SWALE EASEMENT
I-
~
.......,,....,..,..,..,..,..,,_..,..,,....,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,. .,_..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,. ...,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,,...,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,. .,,.m
·,·, ·, ·s·,,·,,·, ,·.·, ·,.·,,
· ,·,·,..,..,..,..,..,..,..,..,..,..,..,..,..,..,. ...,..,..,..,..,..,..,..,..,..,..,..,..,..,..,..,.. :;?
REV
DATE
BY
REVISIONS
SCALE'
AS NOTED
DE:::~::: '.dH~
REVIEWED BY
~
;:-
ISSUE DATE:
JHS
MAY 2017
·····
PANHANDLE
ENGINEERING, INC.
ENVIRONMENTALENGINEERS · CMLENGINEERS · LANDPl.ANNERS
3005SouthHighway77LynnHaven,Florida32444
(850)763-5200 Fax(850)769-0730 pe@panhandleengineering.com
STORMWATER DRAINAGE EASEMENTS
ANDREWS PLANTATION SUBDIVISION
~~~:~~,;~"~:~~;~,':~',,,,,
;::r.~~',::~;;~;~;,,,,
SH EET NUMBER
0::0
11
1-
PROJECT NUMBER
LYNN HAVEN FLORIDA
57916-8
~
~
m
~
0-~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~--01--~~~~~~~~~~~~~~~~~~~~~~·
~
"""............................................................................................................................................................................................................................................................................................................................................................................................................................................................................... ..,,
0
NOT
RELEASED FOR CONSTRUCT ION
BY:
DATE:
ACAO FILE NAME:
57916- Bel .dwg
@PANHANDLE ENGINEERING, INC . .ALL RIGffTS RESERVED . NO PART OF THIS DOCUMENT MAY BE REPRODUCED OR lJTILIZED INAfN FORM WITHOUT PRIOR WRITIENALJTHORJZATION Of PANHANDLE ENGINEERING, INC_
J
OPR CERTIFICATION #EB- 7806
f'-...
FOR SCALE VERIFICATION AFTER DUP LI CATION, THIS LI NE SHOU LD BE !" LONG
"
-·
44 ' DIRECTIONAL BORE
4"
PVC FORCE MAIN w; 4 ·, _ N TAPPING SLEEVE
I
I
------· -- -- - -- - - 8..
PVC REUSE MAIN W
/
8" x _ " TAPPING SLEEVE
8" GATE VALVE
2 - 8 "x1 0 " DI REDUCERS
10" HOPE
[ _:-_"'_:-_-_L- _::-_-_,,,_-_-_
I_----"_-_,_-_-___,~--
- - - - - ., -
_"
1- - - - _ L _ - - -
~-= -
_ _ _ _ _
- ~T--="---FORE
MAM - - -
~_
-
--
-
-
-
--
PROPOSED EDP
I
TO SUBDIVISION
il'-7----i
I
I
wa·=-a·
'
4" FORCE MAIN
I
",~=I
-"
11-~~~o~w-,-.F-.-8-.-P-,-c-w-M-+-- ·--,lf---l----,/-i:-------H-----+---:l-'1-....lfliCROSS SECTION STATIONING
( SEE SHEET 14) (TrP.)
GATE VALVE
_
.
~~
.,
; ;,
-·---\\. -..........___ _____________.,. -I
r "
I
~
CR J 89 _
EXIS T. GRADE
I
I
.
39
...:,
UTILITY SERVICES DETAIL
·a
g,
TURN LAN~
PROPOSED GRADE 1
0'"
m
0
"'0
0
Oo
"m'"
+ ..;
II
II
36
o~
+"
~'"
m
II
0. 2%
n '
0
0 0
ci 0
+ .
0"'
II
:g'"
+'"
II
II
"'
"'
"
0
Oo
~;:!j
II
II
""'"""
""'"""
"'
~~
0
Oo
ci 0
o-
ci 0
+"
:g'"
:;i '"
II
0
Oo
g~
+"
II
II
_J
----- --
~
35 - -
I
B" WATER MAIN TO SUBDIVISION
. · . I'"
FIRE HYD. ASSY AND
POTABLE WATER SERVICE
(SEE DETAIL THIS SHEET)
-
ASSY
TEE
2
·
0
o_
~·
'
I
---
I 1 - 8"
--
~
\' =-\:EXtsr --,;'.~s[ MAIN
I
I
ROW
50 ' DIRECTIONAL BORE
4 " GATE VALVE
4"x6" DI REDUCERS 6" HOPE
2 -
-· -- -- -- I
1
-"-----"' -----., -----"' - 1
' \I
'
"+ ""'
0
"
il: '"
II
~~
"
39
>
-
~~
~
0. 0%
36
. 17%
33
·
DS-40
33
DS-39
DP-34
II
"
30
~
n
30
I
I
27
.."''"'"
..'"
·"'
'"
81 +00
..·'"'"
··
0
82+00
8 J+ OO
.."'''"
8 4+00
0
'"
85+00
86 +00
27
.-'".
·
·"'
"'·
'"
~
"'"
8 7 +00
88+00
'"
89+00
SCALES:
1"=40' HORIZ
1"=8' VERT
a;
QJ
,;::::
(/)
(/)
UJ
z
::s
z
0::
:::J
l-
o
z
<{
CJ
z
1:::J
0
0::
>-
I....J
1:::J
UJ
I-
'\\
(/)
LL
LL
'
0
33
33
-
30
1
-
-
-
27
~
~
-
24
"
i
z
0
30
(/)
27
>
0
ro
24
::::>
(/)
21
~
18
~
~
!
'"
'"
c
~~
0
90+00
9 1+00
"',
·,
··
"'
~
'
92+00
!
·'
·'
93 +00
94+00
95+00
··0
'
96+00
·..·
'
97+00
·
·"'
'
98+00
..''
'"
99+00
·'
"'
·"'
"'
100+00
101+00
''"
"'
21
5
18
I-~
z
102+00
SCALES:
1"=:40' HORIZ
,
9
1"='8' VERT
::s
Q_
(/)
~ t-~,-~~~.,.·B·Y"""!~~~~~~~~~~~~~~~~~~~~-,r-~~~~~~~~~~~~~~'T'~~~~~~~~~~~~~~~~~~'T'~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~...~~~~~~~~~~~~~~-.~~~~~~~~--.;;,...... ~
!
REV
DATE
REVISIONS
DESI GN:~A~:
: : SNOTED
i ~~~~~~~~~~~~~~~R~R; :-:. ~~ ~~~~
. ::PANHANDLE
ENGINEERING,INC,
~?lf:2:~f~~;;;fff',,,,,
OFFSITE UTILITY ROUTING AND TURN LANES
ANDREWSPLAN~TIQNSUBDIVISIQN
-c--e·~
~ 0---+-------f----+--------------------------------01-------------------------0
~ ·--~-----~-~---------------------------''---I S_S_U_E_DA_T_E_'_M
_A
_Y_ 2_0 _17_ _ _ _ _ _ _ _ __.
..,
~ ~:::~N:O~T:"":":::::::o:::oo::~R~EL~E:A~S~ED:":F:O~R~C~O~N:S~T~R~UC~T~I O~N~~B~Y~'~:-:o::~~D~A~TE~,~~:"::":':':::":::~:o:~:::~::"::":!'~AC~A~D: o: :F~IL~E~N~A~M~E:'~5~7~9:1~6~-~B~O·ff·5·''.e·.
13
PROJ ECT NUMB ER
ENVIRONMENTAL ENGINEERS · CML ENGINEERS · LAND PLANNERS
3005SouthH ighway 77 LynnHaven , Flo rida 32444
1.ss.o.11.6.~52.o.
. o. .F.ax. 1a.
.so.11.69. .07.3.o. .
d.w.g. . . . . . . . . . . . . . . . . . . .
@PANHANDLE ENGINEERING, INC. ALL RIGHTS RESERVED_ NO PART OF THIS DOCUMENT MAY BE REPRODUCED OR UTILIZED INANY FORM WITHOUT PRIOR WRITTEN AlJlljORJZATION OF PANHANDLE ENGINEEHJNG, INC_
SHEET NUMBER
LYNN HAVEN FLORIDA
57916 B
gs
~
1
~
~D~P~Ro,;;C~ER~T~IF~IC~A~T~IO~N~#~EB~-~7~B~0~6~........................................-............ ~
W'NW
. . ..p
. a.nh. a.nd
. le. e.n.gl.nee
. nn
.·g·.c·o m
............................................................................
·...............................................................
FOR SCALE VERIFICATION AFTER DUPLI CATION, THIS LINE SHOULD BE
j"
LONG
C/L CR 389
ROW
ROW
. ± 50 '- - - - - - - - - - - - - - - - - - - - 1 - - - - - - - - - - - - - - - - - -± 50'- - - - - - - - - - - - - - - - - - - - l
~-----------------
PIPE JO INT RESTRAINT TABULATI ON
(SHOWING DISTANCE IN FEET FROM THE FITIING TO BE
RESTRAINED TO THE LAST RESTRAINING GLAND REQUIRED)
HOR IZON TAL BEND
TEE S NOM INAL S IZEl
PIPE
10
SIZE 90 DEG. 45 DEG. 22.5 DEG. 11 . 25 DEG. 4
6
8
12
W/0£NING
W/D[N/NG
6' SHLDR'--+-vAR/[$ ($[[ PLANs) -~----- 11 ·- - - - - - + - - - - -11 · - - - - - - + -vAR/[$ ($[[ PLANS)--4-- 6' SHLDR
4
6
8
10
12
MIN. RADIUS FOR 'f'E P IPE IN .FEET
PIPE DIAMETER "D" MIN. RADIUS ~R"
IN INC HES
FOR SOR-1 1
MIN. RADIUS ''R"
FOR SDR- 9
4
2
3
4
6
B
10
20
12
24
B.3
6
B
11.0
16.5
22.0
27.5
33.0
44.0
49.5
55.0
12
16
32
36
40
16
1B
20
1. ) DIRECTI ON BORES FOR FORC E/ WATER MAINS SHALL
US E HDPE DR11/DR9 W/AWWA DIP SIZE' & GREEN/BLUE
STRIPE. FOR HOP E CONNECTI ONS TO AWWA C900 OR
DIP, USE HOPE' MJ ADAPTER KIT ( IND EPEND ENT PIPE
PRODUCTS OR APPROVED EQUAL) . PROVIDE RESTRAINTS
TH REE (3) PIPE JO INTS BEYOND HOP E & PVC/D IP ADAPTER.
2 .) PROVIDE CITY WITH " FRAC OUT PLAN" FOR REVIEW/APPROVAL
ON E WEEK (M IN.) PRIOR TO SC HEDU LI NG WORK.
3 . ) (REFER TO GENERAL NOTE S FOR MOR E INFO,)
55
ALL POLYETHYLENE PIPING SHALL MEET CllY
STANDARDS AND SPECIFICATI ONS
TYPICAL CROSS SECTI ON
la5+oo.oo l
50
45
-:-- -
-·~ -~
~ ~
I~
40
"'
35
--t
' aw
--+
-i._ __,
-""-
c~
- 50
- 40
""
-
- 30
~~
-
- 10
- 20
--
f----
~
'
-
-
----iJZti
0
.
-~
10
- -
~
POLYETH YLENE
(SEE PLANS FOR
S IZE & lYPE)
"==
=40
-
20
30
I
.~
45
-~
MIN.
MQIUS
"R"
w
r
30
..
- ~~
- ~+---
35
..=--:.<
=
9-11.J.J
- Qj~
-
c-
~-
--
f----
Q
-- -~
-=
·Q
20
7
5-50
-
- 50
"
- 40
+ -"'
. ' I- -
~
____'.____
~
=
-30
~
- 20
- 10
0
·-
w
~
10
-+---
-
40
J
.,.
30
20
~ -,
40
30
I RE ~C H
w/
4
6
B
10
WllllH VARIES
12
$ll E OF PIPE
15
50
60
21
24
27
_ _ccc__
15
__J_
30
33
36
!:? ~
~ ~
e
""
II'
---+
=~~
·- ~--\--- ~
~
~
~
1-=::- F=
40
40
··
i..:: -,.,i,·G'.;-+----- -Qi~
35
30
=
25
=
30
----t -~ ---+-
75-50
- 50
- 40
- 30
- 20
0
10
20
30
40
50
60
,_
30
·-+--
50
45
"!'.!=~ -
=
40
35
30
25
20
~
!ii'
0
-
20
'
- 10
0
10
20
30
40
~-
30
--+-_~
1~-=---1
20
~QI
:;;;j;f -
!'1 ·-;
- -
·,
- .-J
-- ~=
_;:i=___:
:_L ·-
_:.,
CO-
40
- --+---
2. TRENCH 81\CKFILL: COMMON FILL COMPACTED TO 95% OF THE
MAXIMUM DENSrTY Ki. PEI< MSHTO T- 180.
J. PIPE BEDDING UTILI ZING SELECT COMl.ION FILL OR BEDDING l;IOCK IN
ACCORDANCE WITH T'l'PE A BEDDING AND TRENCHING DETAIL l.IAY BE
REQUIRED AS DIRECTED BY THE ENGINEER.
4. (*): 15" MAX. FOR PIPE DIAM ETER LESS THAN 24", ANO 24" M'AX .
FOi< PIPE DIAMETER 24" ANO LARGER.
5. WATER SHALL NOT BE PERMITIED IN THE TRENCH DURING CONSTRUCTION.
6. ALL PIPE TO BE INSTAL LED WITH BELL FACING UPSTREAM TO THE
DIRECTION OF THE FLOW.
- 50
- 40
--+-----
- --+_.c
9_ -
- 30
({)
=
UJ
'
UNDISTURBED \
EARTH
==i=-=1=1
.
_________,..,.~'II;-
-
35
30
--==+==
10
20
75-50
10
20
30
40
50
EXIST. HEADWALL EX - 51
-STA:B 1+60.00 OFF:20.52R
/NV OUT:30.32 24" RCP
EXIST. HEADWALL cX- 52
STA:81+60.00 OFF.- 21.81LINV IN:30.07 24" RCP
la1+00.oo l
ow
-=t
40
30
~~
'
~--
.
-
-
~ --
'
~·
~
-20
50
~,
=·-a_=o;_"·
-+-.
~
>'
~.
- 10
a::
M.J .
BELL
/ ·
:::>
A
I--
Cl
NOZZ L ~--,
24" SQUAR E OR ROUND
AND 6" THI CK REI NFORCED
CONCR ETE S HEAR PAD
(S EE NOTE 2)
z
INSTALL WITH
PUMPER NOZZLE
FACING SIREEI
(!)
PROVIDE TEST PLUG
FI NISHED GRADE
AS REQ'D.
-
CONCRETE COLLAR IN
UNPAVED AR EAS
PRECAST TO BE 23 1/2" DIA.
OR 24"x24~x6" THI CK
POURED IN PLACE TO BE
20"DIA.x4" THI CK
0
3
I
-
10
20
la1+00.oo l
~-- ~~- - -
'
30
40
CONCRETE CO LLAR
AND VALVE BOX
{S EE W- 2)
PROVIDE
TEST PLUG
METALLIC LOCATING WIRE
>-
!-_J
!--
:::>
M J HYDRANT
ANC HORING TEE
PROPOS ED
TAPP ING
VALVE
UJ
!-({)
50
!--
a::
'
«---
z
:::>
0
3000 P.S.I.
CONCRETE
±=
w
-I:=
~
z
PROPOSED TAP PIPE
<(
40
30
-o
ccs-e.
- 30
-
--+-
+"
--o<
- 50 - 40
co-g
-
~ -
1-p
::5
I
,m
0
'
- ·QI - -
-
;\
25
10
0
-_:__~a-;~
=
20
I~
o :llL_
A
z
ct_ EXISTI NG MAIN PIPE
/': " .'. "
I'-M-1
.----"'·
20
- 10
~
'\: I
30
L l.J
- 20
'-------" ~
45
15
- 10
TYPE B BEDPING AND IBENCHING PETA!L
-----+---- - ---+---
40
20
- 20
~r ~I~ --+--
~~-=+-=E
50
-+-
-30
NOTES:
1. PIPE BEDDING' SELECT' COMMON FILL COMPACTED TO 95% OF TH te
MAXIMUM DENSrTY Ki. PEI< MSHTO T- 180.
40
.
laa+oo.oo l
30
- 40
-
HOSE
p -_
- 50
-~ ,
=Ji.'.-Cl
1
°-6o
50
t....::'.
.
15
*·
60
e
Q)
la1+60.oo l
_,, "-
(W- 5)
.!::
({)
HYDRANT
OPERATING NUT--~
·-
3:46
3:46
3:46
5:40
5:42
6:24
8 :52
10:08 11 :24
13:51
15:49
i 7:48
19:56 22:47 25:38
3 1:09 35:36 40:04
44:52
51 :16
57:41
61 :00
69:48
78:31
79:46
91 :10 102:33
100:57 115:22 129:48
124:38 142:26 160:15
150:43 172:21 193:53
179:29 205:07 230:46
Q5
~- --1--
N
25
~
--+--·
- 20
3:46
3:46
3:46
3:46
5:40
5:40
5:40
5:40
7:34
7:34
7:34
7:36
9:26
9:26
9 :53 11 :52
11 ; 20
j 1:24
14: 15 17:05
14:10
17:48 22: 15 26:42
19:13
25:38 32:03 38:27
26:10 34:54 43:37
52:21
34:11 45:34 56:58 68:22
43:16
57:41 '72:07 86:32
53:25
71 :13 89:02 106:50
64:38 86:10 107 :43 129: 16
76:55 102:34 128: 12 153:50
--+-
35
-0
---
72
66
3:46
5:40
7:34
9:26
li :20
14:10
17:00
19:50
22:47
28:51
35:37
43:05
51 :17
la9+oo.oo l
40
- 30
99
BB
BO
L
L
L
L
L
L
L
L
L
L
L
L
L
NOT TO SCALE (W - 6)
45
- 40
114
0.380
0.854
1.520
2.374
3.4 18
5.342
7.692
10.470
13.674
17.306
2 1.366
25.852
30.768
BEDDING AND TRENCHING DETAILS
50
- 50
597
398
29B
239
199
159
133
NOT TO SCALE
15
la2+00.oo l
1
°-ao
3:46
5:4-0
7:34
9:26
11 :20
14:10
17:00
19:50
22:40
25:30
28:20
-31 :10
34:00
·8 "·
NOT TO SCALE
20
- 10
16
23
3D
36
42
""
&
TYPE A BEDPING ANP IBENCHING QETAIL
~ -=i=tQ
20
~
"
NOTES:
1. PIPE BEDDING: SELECT COMMON FILL COMPACTED TO 95jf,; OF THE
WJ( IMUM DENSITY NS PER MSHTO T- 180.
2. TRENCH BACKFILL: COMt.40N FILL COMPACTED TO 95:.;: OF THE
WJ(IMUM OENSllY NS PER MSHTO T-1 80.
J. USE TYPE A BEODING TO BE DETERMINEO IN THE FIELO AS DIRECTED
BY THE CITY.
4. (·): 15" MAX. FOR PIPE DIAM ETER LESS THAN 24": AND 24" MAX.
FOR PIPE DIAM ETER 24" ANO LARGER.
15. WATER SHALL NOT BE PERMITIED IN THE TRENCH DURING CONSTRUCTION.
6. ALL PIPE TO BE INSTALLED WITH BELL FACING UPSTREAM TO THE
DIRECTION OF THE FLOW.
7. GRAVITY SEWERS SHALL UTILI ZE lYPE A 8E001NG, IF REQUIRED BY THE
ENGINEER. BEDDING DEPTH SHALi_ BE 4" MINIMUM FOR PIPE DIAM ETER LESS
THAN 15',. MID 6" MINIMUM FOR PIPE DIAM ETER 16" AND LARGER.
8. DEPTH FOR REMOVAL OF UNSUITAB LE t.4ATE RIAL SHALL GOVERN DEPTH OF
BEDDING ROCK BELOW THE PIPE. THE ENGINEER SHALL DETERMINE, IN THE
FIELD REQUIRED REMOVAL OF UNSUITABLE MATElla3+oo.oo l
45
39
55
72
86
102
UTILIJY TESTING AND INSPECTION REQUIREMENTS
.
]!'!
50
4
6
8
10
12
VERTI CAL OFFS CT
WATER MAINS 2 HR_S @ 150 PSI,
FORC E MAINS 1 HR @ 100 PS I.
ALL WATER MAINS AND FORC E MAINS S HALL BE FLUS HED FOR AT LEAST THAT AMOUN T OF TI ME
NEEDED TO FLUSH (2) TI MES 'fHE PIPE VOLUM E AnER (3)fps VELOC ITY IS REAC HED, OR UNTIL
CLEAR. MAX IMUM LENGTH OF PIPE BETWEEN FLUS HING ASS EM BLIES SHALL BE 5,000 FEET.
BEFORE BEGINN ING THE ACTUAL PRESSURE TE STI NG, THE CONTRACTOR SHALL NOTI FY THE CITY,
PR ESSUR5 TESTI NG WIL L BE DON E IN THE PRESENCE OF THE CITY, AND WILL NOT BE
CONS IDERED COMPLETE UNTIL APPROVED IN WRITI NG BY THE CITY ·
1B
§
20
DEAD END
Lengt h
Specification Time far Length (L) Shown, min:s
Time for
Pipe Min.
foe
Oia., Time, Minimum Lon9er
in.
min:s Time, ft. Len9th,s 100 ft. 150 ft. 200 ft. 250 ft. 300 ft. 350 ft. 400 ft. 450 ft.
NOTE:
USE TYPE "B" BEDDING WHEN PIP ING NOT
UND ER ROADWAY,. PARKING LOT, STRUCTURE
OR AS APPROVED BY CITY.
---~
~
50
x
x
x
x
x
PIPE
SIZ E
2. PR ESSUR E. ANO LEAKAGE TESTI NG S HALL BE. IN ACCORDANC E. WI TH AWWA STANDARDS.
L
~
-e=
'
=
~
--+---
CASON DRIVE
'
~
-·-+----- --+-- -
25
+-
29
54
x
x
x
x
12
1
1
14
40
63
FLOR IDA DEPARTMENT OF ENVIRONM ENTAL. PROTECTI ON RU LE S.
INSTALL
GATE VALVE
(SEE 'w -2)
MIN.
AOIUS
NOTE:
US E TYP E "A" BEDD ING WHEN PIPING UNDER
ROADWAY, P.ARK ING LOT, STRUCTURE OR AS
DIRECTED BY CITY.
-~~..,
-~
1 -;;;-~~
---+-
50
'l'l·QI
f--- -~
30
53
74
x
x'
1D
1
24
48
70
1. BACTERIOLOG ICAL TESTI NG SHALL BE IN ACCORDANC E WITH AWWA STANDARDS C651 AND
DIRECTIONAL BORE
ROADWAY CROSSING
~:Ill
x
x
8
'-
1
6
35
56
77
50
_,
--+-
--
x
'28
52
70
88
6
I
18
44
64
83
UTILITY TESTING AND INSPECTION REQUIREMENTS
TRANSITION TO
PVC PIPE
(SEE W- 25)
NOT TO .SCALE (W - 22)
50
40
EDGE OF
PAVEMENT
'
IB4+00.00 I
55
REDUC ER
4
3
30
53
71
89
(W- 11)
40
,
2
2
3
4
4
PIPE JOINT RESTRAINT TABULATION
EXISTING
DITCH OR
PIPE CULVERT
-- -l!1
4
5
6
8
9
PIPE' SIZ ES FOR TEE'S AR E THE BRANC H SIZ E
30
, ,f---
~
-
~
--+-.
---+-
-==ti;-,i_
J<)
'" ..i
o ,w
-
=--q
25
--j.---0 -o.
--~
'=!' -
Q ·li.J.J
~
'
---!i1 ,,,._
.=-.:::t--
30
7
5-50
·- NN
~
=rt~ -
20
-t
4
6
8
ID
12
(W-25)
EXISTING PAVEMENT
ANO BASE
50
PIPE
SIZE
7
10
13
16
19
DIRECTIONAL BORE NOTES
SDR- 9, CLASS 200 FOR POTAB LE WATER & RECLAIMED WATER
SDR- 11, CLASS 160 FOR SANITARY FORCE MAINS
COLOR CODED BLUE FOR POTAB LE WATER
COLOR CODED PURPLE FOR RECLAIMED WATER
COLOR CODED GREEN FOR SAN ITARY FORCE MAIN
N.T.S.
18
·25
32
38
45
PROPOSED
TAP P)PE
~-- RESILIENT SEAT GAT[
VALVE AND BOX
M J ANC H OR I NGc--------~
(SEE DETAIL)
COUPLI NG
NOTE S:
1. FI RE HYDRANT SHALL BE SUPPLI ED WITH A WEEP HOLE.
UND ISTURBED
1 "
j
M.J. SELL
u.
u.
0
FOR SCALE VERIFICATION AFTER DUPLICATION, THIS LINE SHOULD BE
j"
LONG
LYNN HAVEN GENERAL NOTES:
EXISTING SITE REl.ATED ITEMS:
1. THE. LOCATION OF UTILITIES .SHOWN ON THE PLANS MAY NOT BE ACCURATE AND AJ..l LmLmES· MAY NOT BE SHOWN. 'THE LOCATIONS, OF UNDERGROUND UTILITIES HAVE Nm BEEN
PHYSICJJ.lY LOCATED BY THEIR OWNER OR PANHANDLE ENGINEERING, INC.
2. THE EXACT LOCATKm ANO ELEVATION OF EXISTING STRUCTURES, UTILITIES, AND PIPING SHAl.l BE PHYSICALlY VERIFIED IN THE FlB..D BY THE CONTRACTOR BEFORE CONSTRUCTION
BEGINS. THESE DRAWINGS DO NOT INTEND TO SHOW IN COMPLETE OETAIL All EXISTING STRUCTURES, UTILmES, OR PIPlt«l. THE CONTRACTOR SHAl.l EXAMINE All AVAILABLE
RECORDS AND MAKE ALL EXPLORATIOt6 AND EXr.AVATIONS IC REQUIRED TO DETERMINE THE LOCATION OF EXISTING STRUCTURES, UTILITIES, AND PIPING, WHENEVER NECESSARY. THE
OWNER RESERVES THE RIGHT TO CHANGE LOCATION OF LINES TO AVOID CONFLICT WITH EXISTING STRUCTURES, UTILITIES, OR PIPING.
3. THE CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING. THE SURVEY MAY NOT SHOW All OBJECTS 'MTHIN THE PATH OF THE NEW UTILITIES. IF OBJECTS ARE NOT SHOWN ON THE
SUR'YD', THE CONTRACTOR SHALL NOTIFY THE ENGINEER SEVEN MYS PRIOR TO THE BID DllTE. CONTRACTOR Will BE RESPONSIBLE FOR REPLACEMENT OF AJ..l OOJECTS NOT SHOWN
ON THE SURVEY.
4. STATIONING ON THE PLANS RELATES TO THE '2D PLAN VIEW' CENTERLINE OF All ROOJ#AYS/ RIGHT-OF-WAYS AND SHAl.l BE USED FOR LOCATION PURPOSES ONLY. ComRACTOR
SHALL NOT USE STATIONING WHEN CALCULATING PIPE OR RONJWAY LENGTHS. AcnlAL LENGTH l.IAY DIFFER DUE TO VERTICAL. ELEVATION CHANGES AND HORIZONTAL OFFSETS.
5. THE CONTRACTOR Sl-L'iLL PHYSICAl.lY EXN.HNE THE ENTIRE PROJECT SITE AND INFORM HIMSB.f Fl.JllY IN REGARD TO All CONDITIONS PERTAINING TO THE PLACE WHERE THE WORK IS
TO BE PERFORMED FOR PURPOSE OF DaERMINING THE COST TO PERFORM THE WORK. THE CONTRACTOR SHOULD PAY SPECIAL ATTENTION TO .'REAS INVOLVING CLEARING AND
GRUSSING, EXISTI~ FACILITIES REMOVAL AND REPLACEMENT, SUPPORT ON RELOCATION, AND WORK INVOLVED IN Wm.ANO AREAS.
6. THE COlflRACTOR SHALL CHECK PLANS FOR CONFLICTS AND DISCREPANCIES PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL NOTIFY THE OWNER OR OWNER'S ENGINEER OF 00
CONFLICT BEFORE PERFORMltfG 1'Nf WORK IN THE AFFECTED .'REA.
7. THE CONTRACTOR SHALL VIDEO THE ENTIRE ROUTE PRIOR TO CONSTRUCTION ANO PROVIDE A COPY TO THE ENGINEER PRIOR TO CONSTRUCTION.
8. THE CONTRACTOR Sl-L'iLL EXERCISE EXTREME CAUTION IN AREAS OF BURIED UTILITIES AND Sl-L'ill PROVIDE AT LEAST 48 HOURS NOTICE TO THE VARIOUS UTILITY COMPANIES IN ORDER
TO PERMIT MARKING THE LOr.ATIONS OF EXISTING UNDERGROUND UTILITIES IN ADVANCE OF CONSTRUCTION.
9. THE COMTRACTOR IS RESPONSIBLE FOR REPAIRING Nff DN.4AGE TO EXISTING FACIUTlES ABOVE OR BELOW GROUND THAT l.IAY OCCUR IC A RESULT OF WORK CALlED FOR IN THESE
CONTRACT DOCUMENTS.
10, THE CONTRACTOR SHALL BE Fl.JllY RESPONSIBLE FOR 00 ANO Al.l DAMAGES WHICH MIGHT OCCUR DUE TO THE CONTRACTORS FAIWRE TO EXACTLY LOCATE: AND PRESERVE /!Hf AND
All UNDERGROUND UTILITIES.
CONSTRUCTION REGULATIONS AND PERMITS RELATED ITEMS:
11. IT SHALl BE THE RESPONSIBILITY OF THE CONTRACTOR TO LEARN, KNOW, ANO COMPLY WITH THE REGULATIONS, ORDINANCES, PERMIT ANO INSPECTION REQUIREMENTS OF THE VAAIOUS
GO'vERNMENTAL AGENCIES HAVING JURISDICTION. IT 'NILL BE THE RESPONSIBILITY OF THE CONlRACTOR TO REVIEW AND COMPLY WITH THE CONDITIONS OF THE VARIOUS PERMITS OF
THE GOVERNMENTAL AGENCIES. THE CONTRACTOR SHALL SCHEDULE THE REQUIRED INSPECTIONS ANO APPROVALS IN ACCORDANCE WITH THE REQUIREMENTS OF THE PERMIT
CONDITIONS. THE CONTRACTOR SHAl.l OOTIFY THE NECESSARY AGENCIES OF CONSTRUCTION COMMENCEMENT.
12. All SPECIFlr.ATIONS ANO OOCUMENTS REFERRED TO SHAl.l BE OF LATEST ISSUE AND SHAl.l BE COliSIDEREO A PART OF THESE DOCUMENTS AS THOUGH INCLUDED.
13. CONTRACTOR Sl-L'ill HA'ir COPIES OF ALL PERMITS IN ~ESSION AT ALL TIMES DURING CONSTRUCTION. /INi l~DMDUAL CREW OR INDMOUAL PERSON WORKING ON THE
INSTAl.l.ATION OF AfN PART OF THIS PROJECT SHA.LL HAVE A SIT OF PLANS Af¥J SPECIFlr.ATIONS WITH THEM AT All TIMES.
14. THE COtfTRACTOR SHALL FOLLOW ALL CONDmONS OF THE PERMIT REQUIREMENTS. SEE SPECIFICATIONS FOR COPY OF PERMITS,
15. CONTRACTOR SHALl FOLLOW All LOCAL, STATE, AND FEDERAL REQUIREMENTS FOR CONSTRUCTION.
16. CONTRACTOR SHALl FOLLOW All OSHA REQUIREMENTS FOR CONSTRUCTION.
CONSTRUCTION A SITE RESIQRAI!ON RELATED ITEMS:
17. WHERE IT BECOMES NECESSARY TO TEMPORARILY REMO'Y£, REPOSITION, OR SUPPORT EXISTING FACILITIES, UTILITY POLES, ITC. THIS WORK SHALl BE PERFORMED AT THE
CONTRACTOR'S EXPENSE AND IN ACCORDANCE WITH REQUIREMENTS OF THE OWNER OF THE EXISTING FACILITY, UTILITY POLE. ETC. THE CONTRACTOR SHALL GIVE PROPER NOTICE TO
THE UTILITIES.
1B. THE CONTRACTOR SHALL REMOVE ANO REPLACE, TO THEIR ORIGINAL NATURE, AJ..l DISTURBED l.IATERIALS OR OBJECTS WITHIN THE PATH OF THE NEW UTILITIES AS NECESSARY. AJ..l
REPLACED MATERIALS SHAl.l BE EQUAL OR BETTER ANO SHALL BE APPROVED BY THE ENGINEER. THIS INCLUDES All LANDSCAPING WITHIN THE RIGHT OF WAY IN THE PATH OF THE
NEW UTILITIES.
19. All DISTURBED OBJECTS SUCH AS DRIVEWAYS, CULVERTS, REfAIN1NG WALLS, FEOONG, SIGNS, MAILBOXES, LANDSCAPING, ITC. SHA.LL BE REINSTAU.£0 TO EXISTING OR ACCEPTABLE
CONDITION BY THE OWNER AT THE CONTRACTOlfS EXPENSE.
20. All PAVEMENT SHAil BE REMOVED AND 'REPLACED IN N::CORDANCE WITH ENGINEERING PLANS AND SPECIFlr.ATIONS. FOR THE REPLACEMENT OF ASPHALT ROADS ANO PAVEMENT DRWES.
THE CONTRACTOR SHALL REMOVE THE EXISTING ICPHALT ~O REPLACE AS SHOWN IN DETAILS.
21. CONTRACTOR SHALL TRIM, TACK AND WITCH EXISTING PAVEMENT AT LOCATIONS WHERE PROPOSED PAVEMENT ABUTS.
22. Al.l CCMCRm DRIVEWAYS SHALL BE REMOVED AND REPLACED IN ACCORDANCE WITH ENGINEERING PLANS ~o SPECIFlr.ATIONS. FOR REPLACEMENT OF CONCRm CROSSINGS, THE
CONTRACTOR SHALL SAW CUT BACK TO THE CLOSEST JOINT ANO REPLACE AS ~HOWN IN DETAILS.
23. All DISTURBED DRIVES SHALL BE CONNECTED TO THE EXISTING PAVEMENT IN A CONOmON EQUAL TO OR BETTER THAN ITS PREVIOUS CONDITION USING THE SAME' MATERIALS THAT
WERE REMOVED.
24. THE CONTRACTOR Sl-L'iLL MAINTAIN A REASON,.\BLE ACCESS TO All FACILITIES DURING CONSTRUCTION.
25. THE COMTRACTOR SHALL TAKE WHAID£R PRECAUTIONS NECESSARY TO AVOID TRESPASSING AND D>MAGING GOVERtlMENT PROPERTY.
23. All SPOIL ""TERIAL FROM EXr.AVATION SHAl.l BE PLACED ON THE UPLAND SIDE OF Nff SLOPED CONSTRUCTION AAEA.
24. All EXISTING CONCRaE, ICPHALT, TREES, STUMPS, ANO OTHER DELETERIOUS UATERIAL SHAl.l BE REMOVED FROt.i THE SITE AND DISPOSED OF IN ACCORDANCE WITH FLORIDA. LAWS.
26. A ONE FOOT STRIP OF SOD Sl-L'iLL BE INSTALLED ON THE EDGE OF AJ..l ICPHALT OVERLAY AREAS ANO AROUND ALL ABCM GROUND CONCRm STRUCTURES INCWDING BUT NOT
LIMITED TO VALVE PADS, BLOW OFF VAULTS, AND AIR RELEASE VAULTS.
27. All CONSTRUCTION STAKING SHALL BE OONE AT CONTRACTORS EXPENSE
CONTRACTOR IS TO Fl.JRNISH "AS BUILT PLANS" INDICATING LOCATIONS OF All. MANHOLES, FITTil«JS, VALVES, AND DEAD END RUNS WITH THREE (3} PHYSICAL. FEATURES (LOT CORNERS,
TREES, ETC.). THIS IS WANOATORY, NO EXCEPTIONS.
MA!~CE
LYNN HAVEN UTILITY TRENCHES - TESTING NOTES AND SCHEDULE:
LYNN HAVEN UTILITY CONSTRUCTION NOTES:
OF JlWF!C AND ROADWAY RELATED !IEMS;
28. IT SHALl BE THE CONTRACTOR'S SOLE RESPONSIBILITY TO MAINTAIN ADEQUATE TR>fflC CONTROL AND TO PROVIDE DETOURS AROUND CONSTRUCTION ACTIVmES. No ~ SliALl
REMAIN CLOSED TO TR>fflC OVERNIGHT.
29. THE CONTRACTOR Sl-L'iLL INSTALL AJ..l TRAFFIC CONTROL DEVICES REQUIRED FOR THE PROJECT IN ACCORDANCE WITH THE LATEST EDITION OF THE U.S. DEPARTMENT OF
TRANSPORTATION FEDERAL HIGHWAY ADMINISTRATION MANUAL ON UNIFORM TR>fflC ComROL
30. CONTRACTOR SHAil MAINTAIN A REASONABLE ACCESS TO All FACILITIES DURING CONSTRUCTION. All ORrvEWAYS SHAl.l BE COMPACTED AND MAINTAINED OORING CONSTRLICTION TO
ALLOW ACCESS TO FACILITIES AT Al.l TIMES. AJ..l TEMPOfWrr STABILIZATION Sl-L'iLL BE SMOOTH ANO LEVEL
EROSION CONTROL AND OEWATERING ITEMS;
31. PRIOR TO STARTING ANY CONSTRUCTION, THE CONTRACTOR SHALL NOTIFY APPROPRIATE AGENCIES AND SHAJ..l INSTAl.l EROSION CONTROL MEASURES IC SHOWN ON THE PLANS ANO IC
IDENTIFIED, STATE, AND LOCAL NJPRCWAL DOCUMENJS PERTAINING TO THIS PROJECT.
32. THE CONTRACTOR SHALL PROVIDE EROSION .6110 SEDIMENT CONTROL PER THE GUIDELINES OF THE FLORIDll DEVELOPMENT MANUAL, All REQUIRED EROSION AND SEDIMENT COKTROL
MEASURES SHALl BE SHAl.l BE INCWDED IN COST OF OTHER ITEMS OF WORK.
33. CONTRACTOR SHALL INSTAl.l /!Hf REQUIRED SLOPE STABILIZATION, SILT FENCING, BALED HAY BARRIERS, OR TURBIDITY' CURTAlt45 PER CURRENT FOOT DESIGN STANDARDS {FDOT INDEX
100, 101, 102, 103, & 104). LOCATION SHAl.l BE f.S SHOWN ON THE PLANS OR AS DIRECTED IN THE FIELD.
.34. THE CONTRACTOR SHALL BE RESPONSIBLE TO CONTROL CONSTRUCTION AND PREVENT SEDIMENTS FROM DISCHARGING TO ADJACENT PROPERTIES, WETLANDS, STORM DRAINAGE SYSTEMS,
ANO/OR OFF-SITE AREAS, WHETHER SUCH EROSION IS r.AUSED BY WATER, WINO, OR DIRECT DEPOSIT. AT NO AODITlONAL COST TO OWNER, AOOITlONAL EROSION CONTROLS SHALL BE
UTILIZED A.5 NECESSARY AND A.5 'DIRECTED BY THE ENGINEER TO Lit.ilT SEDIMENTS FROM OISCHARGING TO ADJACENT PROPERTIES, WETl.ANO OR STORM DRAINAGE SYSTEMS. THERE Will
BE riCl DIRECT PAYt.iENT FOR THIS WORK.
35. All CONSTRUCTION AREAS SHALL BE STABILIZED 'AT THE CLOSE OF EACH CONSTRUCTION DAY. EROSION ~TROLS SHALL BE CHECKED AT THIS TIME AND MAINTAINED OR REINFORCED
IF NECESSAAY.
.36. EROSION CONTROLS SHALl REMAIN IN PLACE AND BE MAINTAINED FOR THE DURATION OF THE PROJECT TO LIMIT THE MOVEMENT OF SILTATION AND SEDIMENTS FROM ENTERING
EXISTING DRAINAGE SYSTEMS OR FROM LEA\1t4G THE CONSTRUCTION SITE. MN ACCUMULATED SEDIMENTS ARE TO BE REMOVED FROM THE EROSION CONTROLS ANO DISPOSED TO
PROPERLY. HJDmONALLY, All EROSION CONTROLS ARE TO BE INSPECTED AllER A STORM EVENT AND THE CONTROLS REPLACED OR ARMORED A.5 NECESSAR'r' AND ACCUt.iULATED
SEDIMENTS REt.«>VEO.
37. TEMPORARY STOCKPILING OF WITERIAl.S RELATED TO THE COtiSTRUCTION ACTil/ITIES ARE TO BE PROPERLY STABILIZED, PROTECTED ANO DEWRCATED TO LIMIT MATERIAL MOVEMENT AND
EROSION FROM DEPOSITING INTO ADJACENT PROPERTIES, WETLAND OR STORt.i DRAINAGE SYSTEMS.
38. THE INSTALLATION OF All CONCRm STRUCTURES, GRAVITY SEWER, FORCE MAlt6, WATER MAINS, ETC. SHALl BE INSTAl.lfD IN DRY CONDmONS. DEWATERING MAY BE REQUIRED AT
THE DIRECTION OF THE ENGINEER. COMPREHENSIVE PLANS FOR OEWATERING OPERATIONS, IF USED, SHA.LL BE SUBMITTED BY THE CONTRACTOR TO ENGINEER PRIOR TO INSTAl.!ATION.
WATER MAIN INSTALLATION RELATED ITEMS:
1. ALL WATER MAINS SHAl.l BE INSTALLED ACCORDING TO ENGINEERIMG PLANS ANO SPECIFICATIONS
2.
3.
All VALVES AND l.IATERIALS SHALL COMPLY WITH AW#A (AMERICAN WATER WORKS ASSOCIATION) STANDARDS, LATEST EDmON.
All PVC WATER MAINS SIZES 4' TO 12" SHAJ.1 BE AWWA C900 DR 18, COLOR BWE. All PVC WATER WJNS SIZES 3· ANO LESS SHAl.l BE ASTM 02241 SOR 21, COLOR
BLUE. All WATER SERVICE SIZES 2" ANO LESS SHALl BE PE FLD:IBLE TUBIMG P[4710 SOR 9 CTS, COLOR BWE. All DUCTILE IRON WATER WAINS SHAl1 BE SIZES ·4" TO
12" SHALl BE AWWA C151 CLASS 350 WITH CEMENT LINING.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
1, COPIES OF TEST REPOOS FOR ASPHALT, SU6GRAOE, FILL. AND IW:KFlll UNDER ROADWAYS 00 STRUCTURES, AND UTILITY TREMCHES SHA.LL BE PROVIDED DIRECTLY TO
THE EttGINEER FOR APPROVAL. IT SHAl.l BE THE RESPONSIBILITY OF THE CONTRACTOR TO COORDINATE TESTING AND INSURE THAT All APPLICABLE TESfS 1-L'iVE BEEN
PERFORMED. FAIWRE TO OBTAIN TEST RESULTS AT /!Hf POINT OF CONSTRUCTION Will REQUIRE THE REMOVAL OF THE IMPROVEMENT AND REPLACEMENT BY THE
CONTRACTOR. IT SHOULD BE NOTED THAT THE ENGINEER Will REQUIRE COMPACTION TESTING IN ACCORDANCE WITH THE TESTING SCHEDULE FOR UTILITY TRENCH Fill
AND BACKFILL
2. TESTING REQUIREMENTS SHAl.l BE IN ACCORDANCE WITH THE TESTING SCHEDULE CONTAINED WITHIN THESE PLANS. 58.ECTION AND CONmACTING WITH THE TESTING FIRMS
SHA.LL BE THE RESPONSIBILITY OF THE CONTRACTOR. IT SHALL BE THE RESPONSIBILITY OF THE CONTRN::TOR TO COORDINATE AND SCHEDULE All TESTS.
All MAIN LINE VALVES (2"-16") SHAl.l BE RESILIENT SEATED GATE VALVES.
All WATER MAINS SHALl HAVE A MINIMUM OF 36" COVER. IN DITCH BOITOMS, WATER MAINS AND SERVICE LINES SHAl.l BE A MINIMUM OF 5.0' BELOW THE BOTTOM.
DENSITY TESTING SCHEDULE:
ALL MAINS AND SERVICE LINES .SHALL BE DISINFECTED IN ACCORDANCE WITH AWWA C651 . PRESSURE TESTlNG SHALL BE IN ACCOR~CE WITH AW#A C600. CONTRACTOR
SHAl.l NOTIFY CITY'S ENGINEER 'MTHIN 48 HOURS OF PRESSURE TESTING. NO EXCEPTIONS. CITY'S ENGINEER SHALL BE PRESENT DURING BACTERIOLOGICAL SAMPLING ANO
PRESSURE TESTltfG. All WATER w.lt6 SHAl.l BE FLUSHED 0 3 FT PER SECOND ANO 5· TIMES THE PIPE VOLUME SHALL BE FLUSHED.
ALL VALVE BOXES SHALl BE INSTALLED PER DETAIL SHOWN #ID SIT FWSH TO FINISH GRAOE. PRE-CAST VALVE PADS SHA.LL NOT BE USED. All VALVE BOX RISERS SHALl
BE DUCTILE IRON ANO HOT PVC.
All PIPE ANO BACKFlll SHALl BE INSTALLED IN DRY CONOmONS. WELl POINTING OR AWWA TYPE 5 PIPE EMSEDMENT MAY BE REQUIRED AT THE DIRECTION OF THE
ENGINEER.
ITEM
3.
FI LL & BACKFI LL
WHERE THERE IS LESS THAN 12" Clf.6RANCE BETWEEN PVC/01 PIPE ANO OTHER PIPE OR SPECIFIED AREAS. THE PIPE SHALL BE COKCRETE ENCASED WITH 6" THICKNESS
AROUND THE PIPE AND 6" CLEARANCE EACH WAY IN THE AXIAL DIRECTION.
THE CONTRACTOR SHALL USE RESTRAINED JOINT PIPE FOR ALL BENDS, TEES. VALVES. ANO TIWISITION FITTINGS.
All WATER MAIN sHAl.l. BE INSTALLED WITH INSULATED iO GA. TRACER WIRE ANO LOCATOR TAPE SHAl.l ON TOP OF All PIPE, WHICH INCLUDES SERVICE CONNECTIONS. All
LOCATING WIRE SHALl BE CONNECTED AND SHA.LL TERMINATE IN VALVE BOXES AND METER BOXES IC SHDW_N IN THE DETAILS. LOCATOR TA.PE .SHAl.l BE MARKED "POTABLE
WATER BELOW' AND INSTALLED 12" TO 1B' ABOVE THE PIPE
THE COOTRACTOR SHAl.l PRoviOE AJ..l FITTINGS, SLEEVES AND TRANSITION ADllPTERS IC NECESSARY TO COlilPLETE THIS PROJECT.
CONTRACTOR SHALl BE RESPONSIBLE FOR TEMPORARY WATER SERVICE.
FILL & BACKFI LL
UNO ER RONJWAYS
AND STRUCTURES
All VALVES ANO MATERIALS SHALL COMPLY WITH AW#A {AMERICAN WATER WORKS ASSOCLA.TION) STANDARDS, LATEST EDmON.
ALL PVC PIPE LESS THAN 4" SHALL BE ASJM 02241 SDR-21 (200PSI). All PVC PIPE SIZES 4' TO 6' SHALL BE AW#A C900 DR 18 (PC 235). All PVC
PIPE SIZES 10" TO 12" SHALl BE AW#A C900 DR25 (PC 165). AJ..l F'\IC PIPE GREATER THAN 12" SHAl.l BE AWWA C905 OR25 (PC 160).
-4.
5.
6.
7.
All
All
All
All
HOPE PIPE LESS THAN 4" SHALL BE AWWA C901 SDR9 IPS. All HOPE PIPE LARGER THAN 4" SHAl.l BE AW«A C906 SOR11 IPS.
SANITARY SEWER FORCE MAINS SHA.LL BE COLOR GREEH.
FORCE MAIN VALVES (4"-12") SHAl.l BE EPOXY COATED 'RESILIENT SEATED r.ATE VALVES.
SANITARY SEWER FORCE MAINS SHA.LL HAVE A MINIMUM OF 36" COVER. IN DITCH BOTTOMS, WATER tilAiNS ANO SERVICE LINES SHAl.l BE A MINIMUM OF
5.0' BELOW THE BOTTOM.
Al.l FORCE MAINS SHAl.l BE HYOROSTATICALlY TESTED PER AYN/A STANDARD C600 (LATEST EDITION) AT 100 PSIG (MINIMUM) FOR TWO HOURS. CONTRACTOR
SHALl NOTIFY CITY'S ENGINEER WITHIN 48 HOURS OF PRESSURE TESTING. NO EXCEPTim!S.
8.
9.
All FORCE MAINS SHALL BE FLUSHED 0 3 FT PER SECOND ANO 6 TIMES THE PIPE VOLUME (MINIMUM).
10. All VALVE BOXES SHALl BE INSTALLED PER DETAIL SHOWN AND SIT FWSH TO FINISH GRAOE. PRE-CAST VALVE PADS SHALl NOT BE USED. All VALVE BOX
RISERS SHA.LL BE OUCTILE' IRON ANO NOT f'lit.
11 . All PIPE AND BACKFlll SHAl.l BE INSTALLED IN DRY CONOmONs. WELl POINTING OR CLASS I PIPE EMBEDMENT MATERIAL (#67 CRUSHED OR G?>.TED
LIMEROCK OR APPROVED EQUAL) MAY BE REQUIRED AT THE DIRECTION OF THE ENGINEER.
12. THE CONTRACTOR SHAl.l USE RESTRAINED JOINT PIPE FOR All BENDS, TEES, VALVES, ANO TIWISITION FITTINGS.
13. ALL FORCE MAIN SHAl.l BE INSTALLED WITH INSULATED 12 GA. TRACER WIRE ANO LOCATOR TAPE SHALL ON TOP OF ALL PIPE. A1.1 LOCATI~ WIRE SHAl.l BE
CONNECTED ANO SHALl TERMINATE IN VALVE BOXES AS SHOWN IN THE DETAILS. LOCATOR TA.PE SHALL BE MARKED "SANITARY SEWER BELOW' AND INSTALLED
12' TO 18" ABOVE THE PIPE
14. THE COHTRACTOR SHAl.l PROVIDE All FITTINGS, SLEEVES AND TRN-lSITION ADAPTERS AS NECESSARY TO COMPLETE THIS PROJECT.
t
2.
3.
4.
5.
6.
7.
8.
10.
11.
12.
13.
14.
15.
13.
14,
15.
COUPLI~.
8.
9.
10.
11 .
12,
13.
14.
15.
WANHOLES SHAl.l BE A MIN1lill.JM FOUR (4) FOOT DIAMETER AND CONSTRUCTED PER THE STANDARDS AND SPECIFlr.ATIONS.
WANHOLE RING ANO COVERS SHOULD BE 3 INCHES ABOVE GRADE IN UNPAVED AREAS. FIBERGLASS OR STAINLESS STEEL. t.tANt-KlLE CIMR INSERTS
ME REQUIRED AT All WANHOLES WITH Rlt.i ELEVATIONS BELOW 7 FEET NGW.
All MANHOLE BENCHES Stw.l. BE REPAIRED OR REPLACED AS NECESSARY TO HAVE SMOOTH TRN-lSITIONS THROUGH MANHOLE.
All GRAVITY SEWER PIPltfG SHALL BE TESTED IN ACCORDANCE 'MTH UNl-B-6-9B, UNIBELl PVC PIPE CORPORATION. CONSTANT PRESSURE OF 4.0 PSIG
(GREATER THAN THE GROUNOWATER BACK PRESSURE).
All GRAVITY SEWER PIPE (MAINS ANO LATERALS) SHALL f-La.VE AIR TEST ANO COLOR CClV ltiSPECTION COMPLITED ANO APPROVED BY THE ENGINEER
PRIOR TO ROADWAY RESURFACING.
CC1V INSPECTlmlS Sl-W.l. B£ COMPLEfED lt.iMEDIAillY AFTER FLUSHltfG WITH CLEAN WATER. mY DEBRIS ENCOUNTERED Will RESULT IN A FAILED
INSPECTION ANO PRESSURE TEST.
~
GRAVITY SEWER PIPE SAGS SHALl NOT EXCEED MORE ~ 1°'4: OF THE PIPE DIAMaER.
All GRAVITY SEWER LINES MUST BE VIDEOED AFTER SYSTEM IS COMPLETE AND REVIEWED AND APPROVED BY THE CITY. ~OEOS MUST BE DIGITAL
FORl.IAT WITH SYSTEM LOCATION MAP AND INCLUOE IDOOlFICATION FOR EACH MANHOLE ANO SEGMENT OF PIPE. EACH JOINT SHOULD BE ABLE TO BE
VISIBLY INSPECTED THE ENTIRE 360 OEGREES PERlt.IETER AND Ml. LATERAL CONNECTIONS SHOULO BE ORAWN.
90% STANDAR D DENSITY
ONE PER 500 LF HORIZONTAL OR ON E PER 750 SY
WITH A MIN IMUM OF3 TESTS , ALTER NATING LIFTS (12")
ONE PER SOIL TYPE
PER SOIL TYPE
98 o/o OF STAN DARD
DENSITY
ON E PER 200 LF H ORIZONTAL OR ON E PER 750 SY
WITH AMIN IMLiM OF'3 TESTS (PER SECTION OFWORK) 1
ALTERNATI N G LIFTS (12") ON E PER SOIL TYPE
ONE PER SITE OR AT MATER IAL CHANGES
SUBGRNJE U NDER
RONJWAYS AND
STR UCTU RES
98°/o OF MAXIMU M DEN SITY,
MODIFIED PROCTOR
LIMEROCK BASE
UNDER RONJWAYS
AND STRUCTURES
98% OF f\AAXIMUM DEN SITY,
MODIFIED PROCTOR
PER SOIL TYPE ON E PER 200 LF HOR IZONTAL OR ON E
PER 750 SYWITH A MIN IMU M OF 3 TESTS (PER
S ECTION OF WORK)
ONE PER SITE OR AT MATERIAL CHANGES ONE PER
200 LF H ORIZONTAL OR ONE PER 1 200 SYWrTH A
MINIMU M OF 3 TESTS (PER SECTIO N OF WORK)
LYNN HAVEN SPECIAL NOTES:
9.
GRAVITY SEWER INSTAUATION REl.ATED ITEMS:
1.
All GRAVITY SEWER PIPE, MANHOLES, SERVICE LATERALS AND PIPE. BEDDING SHAl.l BE INSTAU.£0 ACCORDING TO ENGINEERING DRAWINGS ANO
SPECIFlr.ATIONS.
2.
THE COKTRACTOR SHALL VERIFY HORIZONTAL ANO l(ERTICAL. LOCATIONS OF All EXISTING SEWER MAINS AND SEWER LATERALS TO BE CON~ECTED TO
PRIOR TO CONSTRUCTION.
J.
Al.l GRAVITY SEWER PIPE SHALL BE PVC UNLESS SPECIFIED OTHERWISE. ALL PVC PIPE SIZES 4" TO 15' AND DEPTHS LJf' TO 10 FEET SHAl.l BE ASTM
03034 SDR-35, DEPTHS GREATER 10 FEET SHALl BE .A.STU 03034 SDR-26. fil PVC PIPE SIZES 18' TO 27 AND DEl7THS UP TO 10 FEET SHALL BE
F679 SOR-35, DEPTHS GREATER 10 FEET SHALL BE F679 SOR-26.
4,
All SEWER SERVICE LATERAL. CONNECTIONS SHALL BE INSTALLED A MINIMUM OF 5 FEET FROM THE NEAREST MANHOLE ANO t-IAVE A 2 FEET MINIMUM
SEPARATION BETWEEN t.iANHOl.E. A1.1 SEWER SERVICE LATERALS CONNECTIONS TO NEW PVC SEWER PIPE SHALl BE "4AOE WITH CASKETED PVC TEE OR
WYE FITTINGS. SADOLE CONNECTIONS SHAl.l NOT BE All.0\fl£0.
5.
fil SEWER SERVICE LATERALS SHA.LL BE 4 INCHES UNLESS NOTED OTHER WISE. THE MINIMUM SEWER SERVICE LATERAL PIPE SLOPE. SHAl.l BE; 4
INCHES=2X; 6 INCHES=' 1"; 8 INCHES=0.5".
6.
LOCATOR TNJE SHAl.l BE INSTALLED 12' TO 18' ABOVE All GRAVITY SEWER MAIHS AND SERVICE LATERALS ANO LOCATER TAPE SHAl.l BE MARKED
·SAHIT~ SEWER BELOW":
7.
AJ..l CONNECTIONS TO EXISTING SEWER MAINS ANO LATERALS OF OISSIMILAA MATERIALS SHAl.l BE M.ADE WITH STRONG IW:K FLD:IBLE REPAIR
DENSITY TEST FREQUENCY
PER SOIL TYPE
UTILITVTRENCH
SNIITAR'Y SEWER FORCE MAIN INSTALLATION RELATED ITEMS:
1. .Al.l SANITARY SEWER FORCE MAINS SHA.LL BE IMSTALLEO ACCORDING TO ENGINEERING PLANS ANO SPECIFICATIONS
2.
DENSITY REQUIREMENT
t6.
17.
18.
19.
20.
21.
22.
CONTRACTOR SHALL. EXr.AVATE AND VERIFY THE EXISTING WATER MAIN LOCATIONS ~O SIZE PRIOO TO SCHEDULING WATER OUTAGE FOR CONNECTION.
CONTRACTOR SHALl CUT ANO REiMM: ASPl-L'iLT RCWlWAYS AS NECESSAAY TO INSTALl NEW WATER MAINS, WATER SERVICE LINES ANO OTHER REQUIRED UTILITY
IMPROVEMENTS.
All RRY STABILIZATION SHAl.l BE SMOOTH AND LE,VEL
PIPE TESTING SHALL BE PERFORMED WITHIN IN ONE WEEK OF COMPLETltfG UTILITY IMPROVEMENTS IN Nff SECTION. SEE TEST SCHEDULE FOR MORE
REQUIREMENTS.
ALL RONJ'NAY. DRIVEWAY AND SIDEWALK RESTORATION SHALL BE COt.iPLmD WITHIN ONE WEEK OF SUCCESSFUL PIPE TESTING IN NN SECTION.
ALL DISTURBED YARD AND GRASSED AREAS SHALl BE SODDED WITH CENTIPEDE.
CONTRACTOR Will BE RESPONSIBLE FOR REPLACING ~ED SECTIONS OF CONCRm CURB.
COST FOR AJ..l NECESSARY REMOVAL ANO REPLACEMENT OF DRIVEWAYS, SIDEWALKS, AND CURBS SPECIFIED ON COMSTRUCTION DRAWINGS Sl-L'ill BE INCWDED
IN LUMP SUM BID PRICE FOR OCH SECTION.
CONTRACTOR SHALL REMOVE AND REPLACE All TREES, SHRUBS ANO IRRIGATION IWAAGED DURING CONSTRUCTION. CONTRACTOR SHALL SUBMIT A WORK
CHANGE DIRECTIVE PRIOR TO CONSTRUCTION FOR mY AOOmONAL COST FOR WORK REQUIRED IN LANDSCAPED MEAS.
CONTRACTOR SHAl.l PROVIDE FITTINGS IC NECESSARY TO MAINTAIN \VATER MAIN SEPARATIO,N REQUIREMENTS. COKTRACTOR Sl-L'iLL RES"JRAIN All WATER MAINS
JOINTS WHERE 6' HORIZONTAL SEPARATIONS CANNOT BE MAINTAINED BElWEEN EXmNG SEWER ANO STORll#ATER UTILITIES.
CONTRACTOR SHAil COMPLETE WATER SERVICE CONNECTIONS TO EXISTING t.iETERS .'flER NEW WATER MAINS HAVE BEEN CERTIFIED ANO PLACED INTO SERVICE.
CONTRACTOR SHAil BE RESPONSIBl.E FOR COORDINATION WITH UTILITY OWNER TO STABILIZE POWER POLES AS THEY ARE ENCOUNTERED THROUGHOUT THE
ENTIRE PROJECT.
REMOVAL ANO REPLACEMENT OF EXISTING ORIVEWAYS AND DRIVEWAY CULVEITTS SHAl.l BE INCLUOEO IN THE. BIO PRICE. NEW DRIVEWAYS SHA.LL MATCH
EXISTING ""TERIALS.
REMOVAL ANO REPLACEMENT OF EXISTING SIGNS, MAILBOXES, SODDING, IRRIGATION, LANDSCAPING, STRUCTURES, ETC. SHAl.l BE INCWDED IN THE BID PRICE.
COMPACTION TESTING SHA.LL BE PERFORMED AT EACH ROADWAY CUT FOR SERVICE LATERALS AND _
PER FOOT SPECIFlr.ATIONS FOR ROAD RECONSTRUCTI~ ANO
SHALL BE l~CLUDED IN THE BID PRICE.
~ AND BACKFlll WITERW.S SHA.LL BE EITHER OF THE SI.ME TYPE AND COMPOSmON A.5 THE WITERIAl.S. REMOYED, OR OF EOUAL OR GREATER STRUCTURAL
ADEQUACY. l,IATERIALS CONTAMINATED WITH DELETERIOUS SUBSTANCES OORING EXr.AVATION SHALL NOT BE USED FOR FILL
THE CONTRACTOR SHAl.1 BE RESPONSIBLE FOR All EXISTING UTILITIES INCLUDING RECOtlNECTING All WATER AND SEWER SERVICES DAMAGED/BROKEN DURING
THE INSTAl.l.ATION ON All PROPOSED UTILITIES ANO OTHER IMPROVEMENTS, 'MTH NO ADDITlONAI.. COST TO THE OWNER.
THE CONTRACTOR SHAl.l AVOID OR MINIMIZE THE DISTURBANCE OF EXISTING TREES DURIMG THE INSTAl.l.ATION OF All WATER MAINS AND OTHER PROPOSED
IMPROVEMENTS WITHIN THE RIGHT OF WAYS ANO EASEMENTS. IF TREES, ARE l'.Wil>.GED OR REQUIRED TO BE MOVED, THEY SHALL BE REPLACED WITH TREES
OF SIMILAR SIZE AND SPECIES WITH NO AOOmONAL COST TO THE OWNER. IF APPLICABLE, THE CONTlt6CTOR WIY USE THE DIRECTIONAL BORE {FOR
PRESSURE PIPE) OR JACK AND BORE (!:OR GRAVITY PIPE) METHODS IN LIEU OF OPEN CUTI1NG TO AVOIO IMPACTS AT CONTRACTOOS EXPENSE.
THE CONTRACTOR SHAJ.1 DIRECTIONAi.. BORE AHO INSTALl HOPE PIPE UNDER ROADWAYS, DRIVEWAYS, OITCH CROSSINGS, ETC. A.5 SHOWN ON THE PLANS.
CONTRACTOR SHALL DETERMINE NECESSARY HOPE PIPE LENGTHS, BORE ENTRY/ EXIT POINTS ANO BORE P!IS TO calPLETE OIRECTIO~ BORE INSTM.LATIOt45.
CONTRACTOR SHAl.l REMOVE ANO DISPOSE OF ALL EXISTING WATER MAINS ANO SERVICE LINES EXCAVATED DURING THE INSTM.LATION OF THE PROPOSED WATER
SYSTEM IMPROVEMENTS. AJ..l ABANDONED SECTIONS OF tfON-EXr.AVATED EXISTING WATER MAIN SHALl BE FLOWABLE FIUED. ALL DEMOLITION AND FLOWABLE
Fill WORK SHAl.l BE INCWDED IN THE 810 PRICE.
CONTRACTOR SHALL PROVIDE THE ENGINEER WITH A MAINTENANCE OF TRAFFIC PLAN PRIOR TO COMMENCEMENT OF CONSTRUCTlotl. SIGNAGE SHAl.l BE
MAINTAINED AT All TIMES AND SHA.LL BE INCLUDED IN THE BIO PRICE..
CONTRACTOR SHAl.l BE RESPONSIBLE FOR ALL BY-PASS PUMPING AND SHALL BE INCLOOED IN THE BIO PRICE.
CONTRACTOR SHALL PROVIDE DE-WATERIMG A.5 NECESSMY FOR 'THE INSTAL1ATION OF All 'PROPOSED IMPROVEMENTS: A1.1 DE-WATERING SHALl BE INCWDED
IN THE BID PRICE.
CONTRACTOR SHAl.1 BE RESPONSIBLE FOR OBTAINING THE NPDES PERMIT AND MAINTAINING THE SILT FENCE, lfflff PROTECTION. ANO >NY OTHER EROSION
CONJRQL NECESSARY IN THE NPOES PERMIT GUIDELINES.
THE CONTRACTOR SHAl.l VIOEO THE ENTIRE ROUTE PRIOR TO CONSTRtiCTION ANO PROVIDE A COPY lO THE ENGINEER PRIOR TO CONSTRIJCTlON .
L{)
~
Ci)
39. THE COMTRACTOR SHALL UTILIZE APPROPRIATE OEWATERING SYSTEMS ANO TECHNIQUES TO MAINTAIN THE EXCAVATED AAE'A SUFFICIENTLY DRY FROM GROUNDWATER AND/OR SURFACE
RUNOFF SO AS NOT TO ADVERSELY AFFECT CONSTRUCTION PROCEDURES OR cAUSE EXCESSIVE DISTURBANCE OF UNDERLYING NATURAL GROUND.
40. WATER FROM TRENCHES AND EXr.AVATIONS SHA.LL NOT BE DISCHARGED INTO H« SANITARY SEWER SYSTEM.
41. WATER FROM TRENCHES AND EXr.AVATIONS SHALl NOT BE DISCHARGED DIRECTLY TO STORM DRAIN SYSTEMS. PROPER TREATMENT TO A SEDIMENTATION AAEA IS TO TAKE PLACE PRIOR
TO DISCHARGE TO MN DRAINAGE SYSTEt.rS.
42. WATER FROM THE TRENCHES AND EXr.AVATIONS SHALL BE DISPOSED OF IN SUCH A MANNER AS TO AVOID PUBLIC NUISANCE. INJURY TO PUBUC HEALTH 00 THE ENVIRONMENT,
DAMAGE OR PUBLIC OR PRIVATE PROPEl?IY, OR IWolAGE TO PUBLIC OR PRIVATE PROPEl?IY, OR DAMAGE TO Tl1E WORK COMPLETED OR IN PROGRESS. SILTATION !WmlERS Sl-W.L BE
UTILIZED f.S NECESSARY.
43. THE COKTRACTOR SHALL REPAIR MN DAW.GE RESULTING FROM THE FAILURE OF THE DEWATERING OPERATIONS OR FROM FAILURE TO t.IAINTAIN ALL THE AAEAS OF WORK IN SUITABLE
DRY CONDITlON.
44. PRECAUTIONS SHAl.l BE TAKEN TO PROTECT NEW WORK FROM FLOODING DURING STORMS OR FROM OTHER CAUSES. GR.'lllNG IN THE AREAS StJRROUt«JING Al.l EXCAVATIONS SHAl.l BE
PROPERLY SLOPED TO PREVENT WATER FROt.i RUNNING INTO THE EXr.AVATED AREA OR TO ADJACENT PROPERTIES. WHERE REQUIRED. TEMPORARY DITCHES SHALL BE PROVIDED FOR
DRAINAGE. UPON COMPLETlON OF THE W~K AND WHEN DIRECTED, All AREAS SHAl.l BE RESTORED IN A SATISFACTORY !o!ANNER ANO AS DIRECTED.
Q)
.!::
(/)
(/)
LlJ
b
z
0
a::
<(
0
z
<("
I(/)
z
0
(/)
>
0
Ill
::>
(/)
z
0
I-
;::
z
:5a.
(/)
.........~~~..........~~~~~~~~~~~~~~~~--~~~~~~~~~~~....~~~~~~~~~~~~~~--~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~.....~~~~~~~~~~~.-~~~~~~~--1s
~ REV
DATE
BY
REVISIONS
SCALE· AS NOTED
STANDARD NOTES
"m~"""''"'- ' E "m
SHEET NUM BER
ti!
··PANHANDLE
0
!-~--~-~--------------~--~_:_E:_:_·_;_:_ _ _ _ _~ ~l~ERING,INC.
~
fl;'
REVIEWED BY: J HS
ISSU E DATE:
MAY 2017
ENVIRONMENTALENGINEERS · CMLENGINEERS · LANDPLANNERS
ANDREWSPLAN~TIONSUBDIVISION
LYNN HAVEN, FLORIDA
=~·
15
57916-B
PROJ ECT NUMBER
!
·
(0
3 -~u~Hig~~n~nnH-n.~rid· 3 -·
~~-~---~-~---------------------------------~
~
NOT
RELEASED FOR CONSTRUCTION
BY:
DATE :
ACAO FILE NAME : 57 916- 8 Detai l Sheets.dwg
(850)763-5200 Fax(850)769-0730 pe@panhandleengineering.com
QPR CERTIFI CATION #EB-7806
t-o '!!-................................................................................................................................................................................................................................................................................................................................................................................L{)
©PANHANDLE ENGINEERING. INC. ALL RIGHTS RESERVED. NO PART OF THIS DOCUMENT MAY BE REPRODUCED OR UTILIZED IN #N FORM WITHOUT PRIOR WRITTEN Al.Jll10flllAnoN OF PANHANDLE ENGINEERING, INC _
FOR SCALE VERIFICATION AFTER DUP LI CATION, THIS LI NE SHOU LD BE j" LONG
All DISTURBED AREAS SHALL BE SEEDED AND
MULCHED UNLESS SPECIFIED OTHERWISE FOR SOD.
IF CONTRACTOR CHOOSES TO USE HYDRO - SEED,
IT MUST ALSO BE MULCHED. ALL MULCH SHALL
BE CUT IN TO MINIMIZE: EROSION.
PIPE 0.0. PLUS 24"
FOR PIPES LESS THAN 18"
PIPE 0.0. PLUS 32" FOR
PIPES GREATER THAN 18"
.J" - 4' CROWN
FINISH GRADE
,
CLEAN COMMON FILL
(SEE. NOTE 2)
FINAL BACKFILL (SEE NOTE 6)
/
LOCATOR TAPE (LOCATOR TAPE SHALL BE INSTALLED
DURING THE' PIPE INSTALLATION AND SHALL NOT BE
INSTALLED BY THE TRENCHING METHOD AFTER PIPE IS
INSTALLED)
.
,
.,
'",
,
/
INITIAL BACKFlLL (SEE NOTE 5)
,
12 GAUGE TRACER WIRE (NOT
REQUIRED ON GRAVrTY SEWER)
/
·~ ~
PIPE EMBEDMENT (SEE NOTE 1)
(SEE PRESSURE PIPE EMBEOMENT OR
GRAVITY SEWER EMBEDMENT FOR
ADDITIONAL REQUIREMENTS)
BEDDING {SEE NOTE 3)
/
"
',"-
"" :-oc;
,
,
FOUNDATION (SEE NOTE 2 IF REQUIRED)
'/
,
'
'
~
UNDISTURBED SOIL
..
~N
NOTES:
,
·12"
1.
INSTALLATION: ALL PIPE SYSTEMS SHALL BE INSTALLED IN ACCORDANCE WITH THE LATEST EDITION OF ASTM D2321 AND
MANUFACTURING INSTALLATION GUIDE.
2.
FOUNDATION: UNSTABLE TRENCH BOTIOl.I MATERIAL ANO j OR ROCK SHALL BE EXCAVATED TO A DEPTH SPECIFIED BY THE
ENGINEER AND REPLACED WITH A SUITABLE MATERIAL PER THE ENGINEER REQUIREMENTS. IN LIEU OF OVER-EXCAVATION, THE
DESIGN ENGINEER MAY SPECIFY THE USE OF GEOTEXTILE TO STABILIZE THE TRENCH BOTIOM.
3.
BEOO!.!'lli.: SUITABLE MATERIAL SHALL BE ASTM CLASS I (#67 CRUSHED OR GRATED LIMEROCK). MINIMUM BEDDING THICKNESS
(MIN.)
y / '
~';,/'.
UNDISTURBED STABLE MATERIAL
CONCRETE ENCASE WATER
MAIN
WATER LINE
WATER LINE
12" MINIMUM
RECLAIMED WATER OR
SEWER FORCE MAIN
LESS TllAN 12"
n
~FORCE
RECLAIMED WATER DR SEWER
MAIN
DETAIL
SCALE: N.T.S.
PIPE DIAMETER VARIES
NOTES:
1. PRESSURE PIPE EMBEDMENT SHALL BE AS n~ CLASS 11 MATERIAL {MINll.IUM), GRAVITY PIPE EMBEDMENT SHALL BE, ASTM CLASS I
MATERIAL, OR PIPE EMBEDMENT MATERIAL AS SPECIFIED BY ENGINEER. PRESSURE PIPE' SHALL BE BEDDED AND COMPACTED IN
ACCORDANCE WITH AWWA C605- TYPE 2 BEDDING REQUIREMENTS FOR PVC PIPE AND AWWA C600- TYPE 2 BEDDING REQUIREMENTS
FOR DUCTILE IRON PIPE. GRAVITY PIPES SHALL BE BEDDED AND COf.IPACTEO IN ACCOROM-lCE WITH ASTM D2321.
2. CLEAN COMMON BACKFILL SHALL BE ASTM CLASS Ill MATERIAL OR BrnER. ASTf.4 CLASS IV OR V MATERIALS SHALL BE USED FOR
BACKFILL. CLEAN COMMON BACKFILL SHALL PLACED IN LAYERS NOT TO EXCEED 12 INCH THICKNESS AND EACH LAYER SHALL BE
COMPACTED TO 90% STANDARD DENSITY.
3. NO TRASH, RUBBISH, ROCKS OR DEBRIS WILL BE ALLOWED IN TRENCHES.
4. ALL PIPE SHALL BE INSTALLED IN ORY TRENCHES.
5. CONTRACTOR MAY BE REQUIRED BY THE ENGINEER TO DE-WATER PIPE TRENCH, IF NECESSARY.
6. BACK FILL FOR PIPE IN WCT TRENCHES SHALL BE ASTM CLASS I MATERIAL (167 CRUSHED OR GRATED LIMEROCK) AND
COMPACTED IN THE TRENCH TO A LEVEL ABOVE THE GROUND WATER.
7. AT THE ENGINEERS DISCRETION, THE CONTRACTOR SHALL SUBSTITUTE SELECT BACKFILL IN LJEU OF NATIVE SOILS FOR A UNIT
PRICE SPECIFIED IN THE CONTRACTOR'S BID FORM.
8. THE CONTRACTOR WILL BE COMPENSATED FOR SELECT BACKFILL ONLY IF DIRECTED BY THE ENGINEER IN WRITING. THE ENGINEER
ldAY ISSUE A FIELD ORDER WITH WRITIEN CONFIRMATION WITHIN 24 HOURS.
DETAIL
CONCRETE ENCASEMENT
_/
SHALL BE 4" FOR 4' - 24" DIAMETER PIPE, AND 5· FOR 30"' - 60" DIAMETER PIPE, AND MECHANICALLY COf.4PACTED TO 95%
STANDARD DENSITY.
TYPICAL PIPE INSTALLATION - UNIMPROVED SURFACE
4.
HAUNCH: SUrTA8LE ldATERIAL SHALL BE ASTM CLASS I (667 CRUSHED OR GRATED LIMEROCK).
COMPACT TO 90% STANDARD DENSITY.
5.
INITIAL BACKFILL: SUITABLE MATERIAL SHALL BE ASTM CLASS I (#67 CRUSHED OR GRATED LIMEROCK). INITIAL BACKFILL SHALL
BE. INSTALLED IN 6" LIFTS ANO MECHANICALLY COMPACTED TO 953 STANDARD DENSITY, INITIAL BACKFILL SHALL EXTEND TO
NOT LESS THAN 6" ABoVE THE TOP OF THE PIPE.
6.
FINAL. BACKFILL: SUITABLE MATERIAL SHALL BE CLASS Ill OR BrnER FOR UNIMPROVED SURFACES' ANO INSTALLED PER TYPICAL
PIPE' INSTALLATION DETAIL SUITABLE MATERIAL SHALL BE ASlM CLASS II OR BrnER FOR ROADWAY SURFACES AND INSTALLED
PER DETAIL.
WCT TRENCHES: SUITABLE MATERIAL SHALl BE AS TM CLASS I (#67 CRUSHED QR GRATED LIMEROCK). BACKFILL SHALL BE
INSTALLED IN 6° LIFTS AND MECHANICALLY TAMPED TO 90% MAXIMUM DENSITY AND SHALL EXTEND TO NOT LESS THAN 6"
ABOVE THE TO OF THE PIPE OR TO THE CURRENT GROUND WATER LEVEL.
7.
8.
HAND FILL VOIDS AND
MINIMUl.I COVER: FOR ALL H-25 TRAFFIC BEARING APPLICATIONS, A ~INIMUM COVER OF 12" IS REQUIRED FOR: 4" - 48"
DIAMETER PIPE, AND 24" FOR 60" DIAYETER PIPE. MINIMUM COVER IS MEASURED FROM THE TOP OF THE PIPE TO THE TOP
OF THE' RIGID PAVEMENT SECTION OR TD THE BOTIOM OF FLEXIBLE PAVEl.IENT SYSTEM.
DETAIL
GRAVITY SEWER PIPE EMBEDMENT
SCALE: N.T.S.
SCALE: N.T.S.
PIPE O.D. PLUS 24"
FOR PIPES LESS THAN 18"
PIPE 0.0. PLUS 32" FOR
PIPES GREATER THAN 18"
PIPE 0.0. PLUS 24"
FOR PIPES LESS THAN 18"
PIPE 0.0. PLUS 32" FOR
PIPES GREATER THAN 18."
,,.
FINAL BACKFILL
NOTES:
1.) INSTALL DETECTABLE WARNING STRIPS
(OWS), AT ALL PEDESTRIAN CROSSWALKS,
ON ROADWAYS, NOT SINGLE FAMILY RESIDENTIAL.
DRIVES. (PER FOOT INDEXS 304)
2.) USE STANDARD CROSSWALK AT STOP LOCATION
AND SPECIAL EMPHASIS CROSSWALK AT ALL
OTHER LOCATIONS (PER FOOT INDEX 17346).
3.) (DWS) COLOR TO BE YELLOW EXCEPT PORTIONS
OF CRA TO BE RED BRICK.
4.) (DWS) TO BE CAST-IN-PLACE ~EPLACEABLE STYLE
AS MANUFACTURED BE ADA SOLUTION, INC.
(www.adatile.com) UNLESS OTHERWISE APPROVED
BY CllY.
5.) CROSSWALK MINIMUM WIDTHS: INTERSECTION CROSSWALK
6' . MIDBLOCK CROSSWALK 10'.
FINAL BACKFILL
PIPE EMBEOMENT MATERIAL SHALL
BE ASTM CLASS II OR BrnER
MATERIAL COMPACTED TO 90%
STANDARD DENSITY TO NOT LISS
THAN 6" ABOVE THE TOP OF THE
PIPE.
PIPE EMBEDtdENT SHALL EXTEND TO
NOT LESS THAN 6" ABOVE THE TOP
OF THE PIPE OR THE CURRENT
GROUND WATER LEVEJ
PIPE BEDDING MATERIAL SHALL
BE ASTM CLASS I MATERIAL
(#67 CRUSHED OR GRATED
LIMEROCK OR APPROVED EQUAL)
COMPACTED TO 90% STANDARD
DENSITY
PIPE EMBEDMENT MAlERIAL SHALL BE ASThl
CLASS I MATERIAL (#67 CRUSHED OR GRATED
LIMEROCK OR APPROVED EQUAL) COMPACTED TO
903 STANDARD DENSITY
.02':1 ' SlOPE
PLACE AGAINST
UNDISTURBED SOIL
PLACE AGAINST
UNDISTURBED SOIL
NOTE: MINIMUM REQUIREMENT FOR WET TRENCHES
MOOIFIEO FOOT lY?E
"E~
NOTE: MINIMUM REQUIREMENT FOR UNSTABLE TRENCH BOTIOM
AWWA TYPE 5 PIPE
CURB & GUTTER
EMBEDMENT
AWWA TYPE 4 PIPE EMBEDMENT
TYPE 'D'
ADA
RAMP
SIDEWALK
ADA
RAMP
BACK FIL ~
SIDEWALK
6"
MIN.
---12'
PIPE EMBEDf.4ENT MATERIAL SHALL BE ASTM
CLASS Ill OR BE'nER MATERIAL COMPACTE D TO
90% STANDARD DENSITY
-~-. -1 -~--
0.0. OF
PIPE
:
6"
l.llN.
....
(DWS)
MODIFIED TYPE "E" CURB
NOT TO SCALE
12~
WHITE
12" WHITE
(DWS)
~-~---------___j
CO NCRETE ENCASEMENT
ADA
RAMP
SIDEWALK
STAN!JARD CROSSWAl.J(
REV
DATE
BY
ADA
RAMP
SIDEWALi<
SPECIAL EMPHASIS CRQSSWAl.J(
REVISIONS
SCA LE ~
DESIGN ED BY:
"'
~
~
0
AS NOTE D
JHS
----~------~--~-------------------------------Of------------------------·
FOR SCALE VERIFICATION A FTER DUP LI CATION, THI S LI NE S HOU LD BE 1" LONG
I'-~
~
.
...,I
. "'s;.,
~
~
oi
l
~
'
~
f-
,._
·
B'
-·
-·
_j
I
I
;,
~
-~
~
~
':
~
4
J'- ·
~
12·
·~
= -
--
Approx. Weight 465 Lbs.
\l___bl J -Q:.
Recommended Maximum Pipe Size:
1
Hardware Cloth
/
~,,...,.
SECTION
FOOT TYPE "E" IN! EI
NOT TO SCALE
J :- ·:
2 0
~ .£__Cl
l
~~
T
l
Cl'.
TYPE C
0
Approx. Weight 235 Lbs.
I(/)
201
z
/,
\~ ----- _'1
(/)
/4
>
...._
0
Bors 0
Ctra.
~ =~~~;!:;~
""
~
1/412"
· Galvanized
[
1------ ....v
wo11- 24 · Pipe
4'-6. Wall- 42 . Pipe
:;;
sf
·~
I-' ~ Eye Bolt
t _Gc.'11·~-- 1 ' See- -Index
-\
Eye Bolt
1/ 4 · Galvanized
Filter Fabric --~
s'·
TYPE E
J'-o·
i
Pl.AN
CAST IRON
,4 ~q,rsctrs.
"
7
I';:;1-
See lndeK 201
·
No. 4 Coarse Aggregate
Min. 2' x 2 ' x 2·
·
I ~----- 1
~ -- ~ .xc,
1- --~I'
!
UJ
~5f
· \ ---
\L _ (..._f
;,
~t,r _j µ_· :Jw·1
si" Hl,_,__J_'_-_o·_--:l § s ol'
·;::: .
~
0
Cl'.
I
"LI·
Pl.AN
4'-4"
UJ
~
""L
I
- ~~---~--~
~
;::
.
I
~
·~
..
~IO II>
~L
·
.i
~
;,
,g ii
' ··
>< {:
;;--
.<:::
21·
J'- o·
·
~
·~
(/)
(/)
I
.
:'? c
Ql
Ql
4 '- 4~
I
2{
-
J'- 4"
0
[(J
::i
Hardware Cloth
No . 4 Coarse Aggregate
Min. 2' x 2' x 2'
'-----:rl
'YI'
SECTION
(/)
Recommended Maximum Pipe Size:
I-
2·-0· Wall-18· Pipe
J'- 1· wa11- 24· Pipe
I-
__-/
/
z
Riter Fabric
0
<{
z
<{
FDOT TYPE "C" INLET
_j
a..
NOT TO SCALE
(/)
REV
i:'
~
~
0
DATE
BY
SCALE :
REVISIONS
AS NOTE D
DESIGN ED BY:
JHS
DRAWN BY:
jdm
REVIEWED BY:
J HS
ISSU E DATE:
RELEASED FOR CONSTRUCTION
BY:
DATE :
ACAD FILE NAM E:
ENGINEERING, INC.
MAY 2017
ENVIRONMENTAL ENGINEERS · CML ENGINEERS · LAND PLANNERS
3005 South Hig hway 77 Lyn n Haven, Florida 32444
57 916 - B Detai l Sheets .dwg
(850)763-5200
0----~------~--~-------------------------------0f------------------------·
NOT
.::PANHANDLE
@PANHANDLE ENGINEERING, INC_ALL RIGHTS RESERVED_ NO PART OF THIS DOCUMENT MAY BE REPRODUCED OR UTILIZED IN ANY FORM WITHOUT PRIOR WRITTEN AlJlljORIZATION OF PANHANDLE ENGINEERJ NG, INC.
Fax (850)769-0730
pe@panhandleengineering.com
STORMWATER DETAILS
ANDREWS PLANTATION SUBDIVISION
James H _Slonina. P_E _39197
James M. Southall , P _E _ 39637
Christopher B _Forehand , P _E_58028
Stephen E. Price, P. E . 7 1646
Jeffrey c_ Pete rmann , P_E. 77540
s
SHEET NU MBER
17
UJ
Cl'.
0
z
<{
[(J
PROJ ECT NUMBER
LYNN HAVEN , FLORIDA
DPR CERTI FICATION # EB- 7806
57916-8
'
(!)
~
O>
I'-L!)
FOR SCALE VERI FICATION AFTER DUP LI CATION, THI S LI NE SHOULD BE j" LONG
'" .
i'
v
~--ft':::jll
'
'
f·
'' -
i
~
I ·
:1 '
"'
"
~
~
[iJ
1 -
Ul
l~_
CONCRETE ENCASEMENT ___/! Ej ' 1LESS THAN
(SEE (g) CONDmON lf2)
:,, ~ 6'
,i
1!~-
:l
PLAN (CROSS IN G)
1
I
:
~
.J
WAlER
''g
SEWER
WATER MAIN
r.IAIN
r
-c -
i'' "'
l-
LESS THAN 12"
'
:, i' SEWER
S'j
I . _I
\.:. _ _.___ .<)
I
-
!
SEWERS AND FORCE MAINS SHALL BE LAID AT LEAST TEN FEET (OUTSIDE TO OUTSIDE) HORIZONTALLY
FROM WATER MAINS.
PROVIDED THE APPLICANT DEMONSTRATES THERE IS NO REASONABLE ALTERNATIVE, THE CllY MAY
APPROVE SMALLER HORIZONTAL SEPARATION DISTANCES FOR SEWERS IF ONE OF THE FOLLOWING
CONDm ONS IS MET;
1. THE TOP OF THE SEWER IS INSTALLED AT LEAST 18~ INCHES BELOW THE BOTTOM OF THE
POTABLE WATER LINE.
2. THE SEWER IS ENCASED IN WATERTIGHT CARRIER PIPE OR CONCRETE.
3. BOTH THE SEWER AND THE WATER MAIN ARE CONSTRUCTED OF SLIP-ON OR MECHANICAL
JOINT PIPE COMPLYING WITH PUBLIC WATER SUPPLY DESIGN STANDARDS AND PRESSURE
TESTED TO 150 psi TO ASSURE WATER TIGHTNESS.
DlllE
I!\'
REVISIONs
llEVISED CEr~IL
llEVISED NOTES
J
1· >WI 17
SEP
2
2~ WM 1J
RE~J H S
I·
~
!'
&
S TANDARDS
DETAIL
TECHN ICAL STANDARDS MANUAL
CITY OF LYNN HAVEN FLORIDA
MANUAL
:.Fl~ ;fE'FTER
~
tit;;~·Th~
,.,.· :t'°'2A~oe~B~'==I~,
27
1
OF
DETAJL
~
W1
"
' ...,.,.,..,,...,,,,,,,..,,,,,,.,,""".,,,,....,...,,.,,,...1o:"""""""""""'""',....~~~~~~~~--'-~-"--'"-~_,0
Do"' ll<>f 18, 2017, l 2'11"'1 liw ID:
~m2Fl0.
P: 1f11-D E<>rbldo Jee Sil-· -
I
CMLJDF~
..... 191&---D o.t.il
~
1 FORD GRIP SEAL
CORPORATION STOP
(C44-44 WG-NL)
".'.---_:>..~--<> -
TO METER
BOX ASSEMBLY
POLYETHYLENE TUBING
{ INSTALL. LOCATING WIRE SEE NOTE 6)
· PRIVATE
MAINTAINED
NOTES:
ALL FITTINGS SHALL BE NO-LEAD BRASS JOINT.
2. ALL PE TUBING CONNECTION SHALL BE COMPRESSION / PACK JOINT
lYPE WITH STAINLESS STEEL INSERTS.
3, ALL TUBING SHALL BE PE4710-CIS SDR9 20DPSI.
4. ALL CURB STOPS SHALL BE LOCKABLE lYPE FORD GRIP SEAL
(B-433-42 WG-NL}.
5. ALL CORPORATION STOPS SHALL BE FORD GRIP SEAL
C44-44-WG- NL) .
6. PROVIDE l/12AWG LOCATOR WIRE ALONG ENTIRE LENGTH OF TUBING.
7. NO SERVICE LINE SHALL TERMINATE UNDER A DRIVEWAY.
8. EACH SERVICE SHALL TERMINATE AT A CURB STOP WHICH SHALL BE
BURIED APPROXIMATELY 3" BELOW FINAL GRADE ANO SHALL BE
CLEARLY MARKED WITH A 2· X 2· X 18~ STAKE WITH THE TOP
PAINTED BLUE AND MARKED WITH THE NUMBER OF THE LOT TO BE
SERVED AND lYPE OF SERVICE PROVIDED. i.e., POTABLE WATER OR
RECLAIMED WATER.
25 LB. BRONZE GATE VALVE
W/RISING STEM (NOT BY CITY)
M
%~ LOCKABLE lYPE
FORD GRIP SEAL CURB
STOP (B--433-42 WG-NL)
FORD DOUBLE STRAP
TAPPING SADDLE
1" DUAL CHECK VALVE (WATTS
MODEL 07S OR APPROVED EQUAL)
METER TO BE CENTER
UNDER METER BOX DOOR
WATER MAIN
AWWA lYPE CC THREADS
SECTION
'
WATER SERVICE CONNECTION
~
1
'!'
5
I·
l
PET~L
~~
!'
~
I
I
i'
2
14 WAR 17
SEP
RElllSED
~
NOTES
l::~
t:l~:~·~·~~~"
::J"~'~'liiit:E~C~~...N~~cill:;:A:L::::::::::J.~-----G-A-T-E-V-A-L-V-E-A-N-D-B-0-X----~-~-,~---'({-t-c°-'-'---11
DETAIL
2 '"~A~'~"E
27" ''::::::)~
0
S TANDARDS
i~·~Th::I:
TECHN ICAL STANDARDS MANUAL
EETl(I;
M ANLJAL.
OF
DETAIL
CITI OFLYNN
W~2
HAVEN FLORIDA
"ll~n.,::ii,,~.m,,~.,,.....,~~"'"°"~~""'·~·~m"""-,_,~~==·~B...·-~~""~'m"'rl~~'""""·"""m,.-.,~~=,n,-.r:c-------------'----'--_,
REV
2
25 MAR ! 3
REFIJHS
ADDED IDCT AT METER
i
80~
00 :=-~-~'({~-t,~,-,g,~~~~~~<'
~~
~:i~·t·~·t~
il:~"~liOt;:~:~H~Nuw~c~"~jOL"'Wi:iiiiiO:::i~------W-A-T-E-R-S-E-R-V-l-C-E------:-~~~·~~I-
STANDARDS
~
iJ
0
II
I!
NOTE:
1. ALL FITTINGS SHALL BE NO-LEAD BRASS.
2. ALL WATER METERS SHALL HAVE A DUAL CH ECK VALVE.
~
'5
''
I
WATER SERVICE DETAIL
i'
::J
SEWER EN CASEMENT
~
1.
,
WATER AND REUSE VALVES:
1. 2~-12": SHALL BE AWWA C509 DUCTILE IRON EPOXY COATED
RESILIENT SEATED GATE VALVES.
2. 16" AND LARGER: SHALL BE AW'NA C504 DUCTILE IRON EPOXY
COATED RESILIENT SEATED BUTTERFLY VALVES.
-
!
WATER OR
REUSE MAIN
(·) METER BOX
I'
'~
T ECHN ICAL
CITY -
!
NOT TO SCALE (W- 2)
~
l::t:l:Ji:~-/tjj'::J~,~"Olt;~otllroii:.J...~·i:Jiiocjjj;c~ro:ilj·~"i:J.~-------------------~-------1 '
AWWA TYPE
CC THREADS
(*) METER AND METER BOXES
BY CITY FOR 2n LINES AND
MAINTAINED
'~
GATE VALVE AND BOX DETAIL
l
«:
1======
SMALLER
'
I
NOT TO SCALE
1 - FORD GRIP SEAL
ORPORATION
STOP(C44-44-WG-NL)
PVC
lI
ROCK
~
SEWER ENCASEMENT DETAIL
REV
~BEDD IN G
NOTES:
1. PVC EXTENSIONS SHALL NOT BE USED ON VALVE BOX INSTALLATION .
2. THE ACTUATING NUT FOR DEEPER VALVES SHALL BE EXTENDED TO
COME UP TO 4 FOOT DEPTH BELOW FINISHED GRADE.
3. VALVE EXTENSION SHALL HAVE SET SCREW INTO 2" OPERATING NUT.
4. ALL BELOW GRADE NUTS ANO BOLTS SHALL BE STAINLESS STEEL.
5. ALL VALVE COVERS TO BE PAINTED WITH EPOXY PAINT.
6. WATERMAIN (BLUE), FORCEMAIN {GREEN), FIREWATER (RED) AND
RE-USE (PURPLE)
'
SECTI ON (PARALLEL)
1~
I
'~
4· MIN. {lYPICAL)
SECTI ON (CROSS IN G)
WATER MAIN
I!
CONCRETE ENCASEMENT'
r --r--:-,
(SEE (g} CONDITION #2)-----.i...0~-~
iS_E_W_E_R_ _~
,
-
RESTRAINED
JOINTS (lYP.)
(· ) DOMESTIC SERVICE MffiR
PLAN
II
RESILIENT SEAT M.J.
GATE VALVE
G]
===i [
'5
''
SEE NO'TE 2
I
i
FORD DOUBLE STRAP
TAPPING SADDLE
!
FINISHED
'5
LESS THAN 12~
LESS THAN 12"
l4 TOfAL) (SEE NOTE 5)
~
CONCRETE ENCASEMENT
(SEE {g) CONDmON #2)
~
W/T-'J."3 131\R EACH WAY
~
,)i
':
COLLAR
kN4 ~U~P~V~D 6.eR&cK
~-- CONCRETE
SET TOP OF VALVE' BOX
TO FINISHED GRADE
PLAN (PARALLEL)
WATERTIGHT CARRIER PIPE
(SEE (g) CONDITION 1/2)
1 ~ POLYETHYLENE'
TUBING (PE4710-LTS
SDR9 200PSI}
·I
l-'
{· ) IRRIGATION SERVICE METER
PLAN
.:
~ , VI
:
, I
PVC
G j 1======
===i [
'
'
PROVIDE IRRIGATION ONLY
IF RE,-USE NOT REQUIRED
1~
FORD DOUBLE STRAP
TAPPING SADDLE
b
,.
NOlE·
1~ POLYETHYLENE
TUBING (PE4710-LTS
SDR9 200PSI)
-'
WATERTIGHT CARRIER PIPE
(SEE (g) CONDmON {f2)
'
I~
z
'I
'':
CONCRETE ENCASEMENT
(SEE (g} CONDITION #2)
30 APR 07
1&--9 E0..- 10: 1"'2Flle: P:
I CNLXlFo~
SEl'
l::E
t:l~~~"!;"~~
"::J~'~T.ilt:E~c~H"'-:N~~c~·t~=~LOE;~::::::i~------W-A_T_E_R_S_E_R_V_l_C_E______~~-·~-: -':c-,-c'-,-,---1~
S
o ETAfl
W3
c
lo'iO 1'911--9 llolofl ~'"l
~
RElllSED DETIJL II NOlES
__,
.,,,,..,..,...,.,,.,.,.,...,
....,,.,...,,,,,,.....,....,""'.t.""'""'""'"""'""',,,...~~~~~~~~~..&..~-"~-'--~-'®
l:2.,_
-Doteo- lloy Tl. lllll,
14 WM 17
1-"'"-~~~'="='=2~'--~ ~'
DETAIL
TECHN ICAL STANDARDS MANUAL
Cln'OFLYNN HAVEN FLORIDA
MANUAL
~l~
i'
D.-TE
CONNECTION DETAIL
TECHNICAL STANDARDS MANUAL
TAN DAROS
M ANUAL
~~-~"'=='~"~""~"~"m'===I~
I>"-m_~~--''="~2~'--~ '
DET"'-
~
""""""'"''""'""""''"",....""""""',,...,""...,...,."'"""'""'.,..."""'""~c~'"~
' '->-'-'"-'-"-~-~
->c_o_·_~______..___~w~-4
..;.._ __,®
Oo!o; "°1
1~
ZOi l.
~
°"'
O;
1"'2Flls 1"
!~
Eoa!oldo J!lll 00--- S.- 1 CMLJIFo~
~"'P
1'916--9 Dol:o;I
~
WATER ANO REUSE YAl.\IES
1.
2.
12· AND LESS SHALL BE EPOXY COATED RESILIENT SEAT GATE VALVES.
16· AND ABOVE SHALL BE EPOXY COATED RESILIENT BUTTERFLY VALVES.
POTABLE
AND REUSE WATER MAINS
1.
INSTAil. WITH
PUMPER NOZZLE
FACING STREEr
UTILITY TESTING AND INSPECTION REQUIREMENTS
K3 REQ'D.
1. BACTERIOLOGICAL TESTING SHALL BE IN ACCORDANCE WITH AWWA STANDARDS C651 AND
FLORIDA DEPARTMENT OF ENVIRONMENTAL PROTECTION RULES.
PIPE JOINT RESTRAINT TABULATION
(SHOWING DISTANCE IN FEET FROM THE FlTTING TO BE
RESTRAINED TO THE LAST RESTRAINING GLAND REQUIRED)
2. PRESSURE AND LEAKAGE TESTING SHALL BE IN ACCORDANCE WITH AWWA STANDARDS.
WATER MAINS 2 HRS 0 150 PSI,
FORCE MAINS T HR 0 100 PSI.
ALL WATER MAINS AND FORCE MAINS SHALL BE FLUSHED FOR AT LEAST THAT AMOUNT OF TIME
NEEDED TO FLUSH (2) TIMES THE PIPE VOWME AFTER (3)fps VELOCllY IS REACHED, OR UNTIL
CLEAR. MAXIMUM LENGTH OF PIPE BETWEEN FLUSHING ASSEMBLIES SHALL BE 5,000 FEET.
BEFORE BEGINNING THE ACTUAL PRESSURE TESTING, THE CONTRACTOR SHALL NOTIFY THE CllY,
PRESSURE TESTING WILL BE DONE IN THE PRESENCE OF THE CITY, ANO WILL NOT BE
CONSIDERED COMPLETE UNTIL APPROVED IN WRITING BY THE CITY.
Pipe Min.
Dia .. Time,
Length
fo'
4
3:46
6
5:40
7:l4
9:26
11:20
14:1D
17:00
19:50
22:40
25:30
28:20
31:10
34:00
8
,0
12
T5
T8
21
"
""
27
JO
597
398
298
239
T99
0 .380 L
3:46
3:46
D.854
1.520
2.374
3.418
5:40
5:40
3:46
5:40
7:l4
9:26
11 :20
7:34
9:26
11:20
7:34
9:26
11:24
7:34
9:53
11 :52
14:15
17:05
159
5.342
14: 10
14:10
17:48
22:15
26:42
T3J
TT<
99
7.692
10.470
17:00
19:50
22:47
28:51
35:37
43:05
51 :17
19:13 25:38 32:03 38:27
26: 10 34:54 43:37 52:21
34:11 45:34 56:58 68:22
43:16 57:41 72:07 86:32
53:25 71 :13 89:02 106:50
64:38 86:10 107:43 129:16
76:55 102:34 128:12 153:50
..
BO
72
66
13 .674
17.3D6
21 .366
25.852
30.768
L
L
L
L
L
L
L
L
L
L
L
L
3:46
5:40
3:46
5:40
7:36
25
32
38
4S
6
8
TO
T2
t.I J HYDRANT
ANCHORING TEE
PIPE
SIZE
4"
x
4
6
8
TO
T2
Longer
Min imum
min:s Tlme , ft. Length,s TOO fl 150 ft. 200 ft. 250 fl JOO fl
ii\.
HORIZONTAL BEND
PIPE
SIZE 90 DEG. 45 DEG. 22.5 DEG. 11 .25 DEG.
418
7
4
2
Speclflcotlon Tlme for Length (L) Shown. mln:s
Time for
PVC PIPE 3" AND LESS DIAMETER SHALL BE ASTM DD2241;
SDR- 21 (200PSI) .
2. PVC PIPE 4"-12~ SHALL BE AWWA C900 DR 18 (PC- 235PSI).
3. PVC PIPE GREATER THAN 12 .. SHALL BE AWWA C905 DR18
(PC- 235PSI).
4. FITTINGS AND VALVES 4 ~ ANO GREATER SHALL BE MECHANICAL
JOINT DUCTILE IRON (250 PSI MIN.) .
5. MECHANICAL JOINT RESTRAINTS SHALL BE UTILIZED TO RESTRAIN
NEW PIPE AND FITTINGS.
6. CONCRETE THRUST BLOCKS SHALL BE UTILIZED TO RETRAIN
EXISTING PIPES AND FITTINGS.
7. ALL POTABLE WATER MAINS SHALL BE COLOR BLU E. ALL
RECLAIMED WATER MAINS SHALL BE COLOR PURPLE.
ALL FLUSHING REQUIREMENTS PER AWWA STANDARDS (3 fps
MINIMUM., 2 X PIPE VOLUME MINIMUM.)
9. ALL WATER MAINS SHALL BE HYDROSTATICALLY TESTED PER AWWA
STANDARD C600 {LATEST EDITION) AT 150 PSIG {MINIMUM) FOR
TWO HOURS.
1D. ALL WATER MAINS REQUIRE DISINFECTION PER AWWA STANDARD
C651.
11. DUCTILE IRON PIPE AND FITTINGS FOR POTABLE WATER ANO REUSE
MAINS SHALL BE CEMENT LINED IN ACCORDANCE WITH .ANSl/AWWA
28
52
70
88
T9
5-
x
x
30
53
74
J:46
3;46
J:46
5:4D
5:42
6 :24
8:52 10:08 11:24
13:51
15:49
17:48
19:56 22:-47 25:38
31:09 35:36 40:04
44:52 51 :16 57:4 1
61:00 69;48 78:31
79:46 91:10 102:33
100:57 115:22 129:48
124:38 142:26 160:1S
150:43 172:21 193:53
179:29 205:07 230:46
2
3
4
4
6
8
9
16
REDUCER
8-
x
x
To-
A
29
S4
350 ft. 400 ft. "50 ft.
M J ANCHORIN'n--------~
COUPLING
NOlES:
1. FIRE HYDRANT SHALL BE SUPPLIED WITH A WEEP HOLE.
2. THE DEVELOPER MAY INSTALL lHE SHEAR PAD RECESSED UP TO
4 INCHES BELOW FINISHED GRADE AND SOD lHE RECESSED SECTION.
3. CLEARANCE BETWEEN BOITOM OF BOLTS AND TOP OF SHEAR PAD
SHALL BE A 6" MINIMUM.
4. APPROVED F.H. MODELS ARE AMERICAN DARLING B-8-4-B, M+H A-129,
Al/K. & CLOW NO SUBSTITUTIONS WILL BE AL.LOWED.
5. lHERE SHALL BE A STORZ FITTING ON lHE 4· STEAMER CONNECTION.
6. FIRE HYDRANT SPACING St-W...L NOT EXCEED 500 FEET IN RESIDEN11AI... USES
OR 300 FEET IN NON-RESIDENTIAL USES. SPACING SHALL BE MEASURED ALONG
lHE CENTERLINE OF THE ADJACENT ROADWAY OR ORMNG AISLE, OR ~ omRMINED
BY THE CITY.
7. A FIRE HYORANT WILL BE REQUIRED SUCH THAT THE FIRE DEPARTMENT DOES NOT HAVE
TO PASS BY N('( PORTION OF A PROJECT WITHOUT FIRST ACCESSING A HYDRANT LOCATION.
s
1D
T3
12
x
x
x
x
x
x
x
x
x
so
PIPE
SIZE
TEE S
4
6
3
30
S3
7T
89
1
18
44
64
83
DEAD ENO
4
6
8
TO
T2
NOM NAL SIZE1
8
TO
12
T
1
1
6
T
1
3S
24
14
S6
48
40
77
70
63
a.
VERTICAL OFFSET
39
55
72
86
T02
T6
23
30
36
42
C104/A21 -4-
NQIES:
PIPE SIZES FOR TEE"S ARE THE BRANCH SIZE
PIPE JQl!:fi RESTRAI NI IA6!.! l,h]QN
NOT TO SCALE
~
~
~
~
i:.
g
!
·
'
i
I
0
i
If
~
~
~
i
FIRE HYDRANI ASSEM6LY DETAIL
NOT TO SCALE
f
0
~
~
~
Ii
II
"
&
UTILITY TESTING AND
TECHNICAL
LNSPECTION REQU IREMENTS
TECHN ICAL STANDARDS MANUAL
·CITY OFLYNNHAVENFLORlOA
S TANDARDS
M ANUAL
Doto;
~ !~
lelll.
"24Po' Uoet Ilk
~lll!Fllo
P: \0,,1! 8 8-ioSD ~
llo,.. 11
C MLJDF~
..,.\01916---8 lloloil
;~
WATER
· ~·
'" 27
5
~
~
I
e
30 APR 07
·
~M
W-5
'
-------------------.--------4~
FIRE HYDRANT
~,,~~·~~-::::i':j
1--.......- - - - - - - - - - - - - .....
T EcHN ICAL
S TANDARDS
MANUAL
~TE:
ASSEMBLY DETAIL
TECHNICAL STANDARDS MANUAL
CITY OFLYNN HAVENFLORIDA
-=-
~
30APR 07
"'"m=
~~
' -·~~
"~-_, o
w
" ~_~
"lln::'1!"l!'rnl::'l""l~11:i>ll'm-.'!::nn-;::::1rmir.l::=.=
·, .-:ll'!-m,,~
- -·,n,~...,.._,
·=-~-----------.._
Oo1to lloy ll .lllll. ll.,_ L11or Ilk f....:!Fll ~ P: Ji l i-~ Eoelt... S Sil- I Cl'll~F
..,. ,. _,~-=
"""
8
______
.,.,
>
15
i
I CAO FlLL
~
00
0
ro
~
o
"
e
s
~
TANDAROS
MANUAL
~
Oolot "°1 I& lll11. l;2lpt0
PIPE JOINT
TEcHN ICAL
~Ilk
f.-.!Fl\o'. P:
li--ll
Eoal>'"' S
SD -
\ I !;!YllllfoOlo
..
00 Flll:o
~~
~l~
RESTRAINT TABULATION
TECHN ICAL STANDARDS MANUAL
Cln' OFLYNN HAVEN FLORIDA
HEIT ND:
WATER
'"
30APR07
11 OF 27
DETAIL
W-11
1 ~-1- . ""'J
I-
w',~
z~
!0
....J<(
~
Q.
~
;;;,
.........~~~..........~~~~~~~~~~~~~~~~--~~~~~~~~~~~....~~~~~~~~~~~~~~--~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~.....~~~~~~~~~~~.-~~~~~~~--1s
P_E_39197
W
REV
DATE
BY
SCA LE ~
REVI SIONS
R~:::~
AS NOTE D
::-:::
DESIGNED BY:
JHS
.::PANHANDLE
ENGINEERING, INC,
James H_ Slonina.
WATER UTILITY DETAILS
ANDREWS PLANTATION SUBDIVISION
~~:i·:~:~:~£~;:::i'"""
"'*"c ""~'""''"""
SHEET NUMBER
18
57916 B
PROJECT NUMBER
"'
~
ISSUE DATE:
MAY 20 17
ENVIRONMENTALENGINEERS · CMLENGINEERS .
LANDPLANNERS
LYNN HAVEN FLORIDA
~
:,
CD
~
~
----~------~--~-------------------------------Of------------------------·
0
"'"'. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . L()
NOT
RE LEASEO FOR CONSTRUCT ION
BY:
DATE :
ACAD FILE NAM E:
57916-B Detai l Sheets .dwg
@PANHANDLE ENGINEERING, INC_ALL RIGHTSRESERVED_NOPART OFTl-llSDOCUMENT MAYBE REPRODUCEDOR UTILIZED IN#N FORM WITHOUT PRIORWRITTEN AlJll10RIZATIONOF PANHANDLE ENGINEERING, INC_
3005 South Highway 77 Lynn Haven, Florida32444
(850)763-5200
Fax(850)769-0730
pe@panhandleengineering.com
J
DPR CERTIFI CATION #EB - 7806
.
-
O>
f'--
FOR SCALE VERIFICATION AFTER DUP LI CATION, THIS LINE SHOULD BE j" LONG
TROWEL-FINISHED
CONCRm BENCHING
·
PR ECAST
COHCRm BASE
wr
HOLE
LL
SEE MANHOLE
CONNEcnON
DETAILS (S-2)
MANHOLE COVER USE
U.S. FOUNDRY &: MFG. CORP .
USF 750 RING ANO Kl COVER
ITEM No.9220022'
(SEE DETAIL S-4)
~-FRAMES
INSIDE WALL
MIN.~ ~
~OUTSIDE
PRE-PRIMED
JOINT SURFACES
f a·· MIN .
WALL
PRECAST
MANHOLE
WALL
.I
'
"
'
PRE CAST
MANHOLE
WALL
.
PVC OR DIP
~=::::::::P"l::::;-----j
.
·
-~-1
TABLE
"
WITH SQUEEZE-OUT
-1,0
~----- 2"
------~
CAST-IN-PLACE
CONCRETE BASE
MIN .
NOTES:
1. DROP PIPE AND FITIINGS SHALL BE OF EQUAL SIZE ANO MATERIAL AS
THE INFLUENT SEWER.
2. THE CITY MAY APPROVE ALTERNATE WATER TIGHT CONNECTION DETAILS
FOR CONNECTION OF 24" DIAMETER PIPES AND LARGER.
3. AN OUTSIDE DROP CONNECTION SHALL BE REQUIRED FOR ALL INFLUENT
WHICH HAVE AN INVERT 2' OR MORE ABOVE THE MANHOLE INVERT.
NOTES:
MANHOLE SHOWN IS FOR SEWER. SIZE BA THRU 24".
DROP CONNECTIONS MAY BE ALLOWED WHENEVER INVERT OF INFWENT SEWER IS 24" OR
MORE ABOVE THE MANHOLE. SEE tMNHOLE CONNECTION DETAILS.
APPROVED CONCENTRIC CONE DESIGN MAY BE USED AS AN ALTERNATIVE.
GROUT INSIDE JOINT AREAS OF NEW SEWER MANHOLES
ALL MANHOLES SHALL HAVE INTEGRALLY CAST HOPE LINERS (HANSON OR APPROVED EQUAL)
30
3J
11
14
17
20
22
25
2B
31
3J
36
J9
42
12
15
IB
21
24
27
JO
33
36
J9
42
45
V1600·3
LOAD RATING
1
JI"
COATING
UNOIPPEO
ESTIMATED WEIGHT
COVER: 1J5 LBS
FRAME: 11B LBS
UNIT: 25J LBS
(2) CLOSED
PICKHOLES
MATERIAL SPECIFICATION
COVER· GRAY IRON
ASTM A48 CL358
FRAME· GRAY IRON
ASTM A48 CL358
Minimum Test nmes for Various Manhole Diameters
in Seconds
Diameter, in.
OEPTH (FT)
B
10
12
14
16
18
20
22
24
26
2B
30
STANDARD PRECAST MANHOL£
PIPE CONNECTION
JOINT DETAIL
PRECAST MONOLITHIC
BASE
STAINLESS STEEL
PIPE CLAMP
RESILIENT
CONNECTOR
1
CATALOG NUMBfR
HEAVY DUTY
1
SQUEEZE-OUT
COMPLCTED JOINT
9"T
-1,l-
4.
5.
·
1" DIA
HANDLING HOLE
MANHOLES SHALL BE TESTED FOR LEAKAGE BY NEGATIVE AIR PRESSURE AS
PRESCRIBED IN ASTM C 1244 TO DEMONSTRATE THE INTEGRITY OF THE
INSTALLED MATERIALS ANO THE CONSTRUCTION PROCEDURES. THIS TEST
METHOD SHALL BE USED FOR TESTING CONCRETE MANHOLE 'SECTIONS
UTILIZING MORTAR, MASTIC, OR CASKETED JOINTS AND IS INTENDED TO
DEMONSTRATE THE CONDITION OF THE CONCRETE MANHOLES PRIOR TO
BACKFILL. IN ACCORDANCE WITH THE ASTM C 1244. THE TEST HEAD SHALL
BE PLACED AT THE TOP OF THE MANHOLE IN ACCORDANCE WITH THE
MANUFACTURER'S RECOMMENDATIONS. A VACUUM OF 10 IN. HG SHALL BE
DRAWN ON THE MANHOLE. THE VALVE ON THE VACUUM LINE OF THE TEST
HEAD CLOSED, ANO THE VACUUM PUMP SHUT OFF. THE TIME SHALL BE
MEASURED FOR THE VACUUM TO DROP TO 9 IN. HG. THE MANHOLE SHALL
PASS IF THE TIME FOR THE VACUUM READING TO DROP FROM 10 IN . HG TO
9 IN. HG MEETS OR EXCEEDS THE VALUES INDICATED IN ASTM C 1244
TABLE 1, SHOWN BELOW. IF THE MANHOLE FAILS THE INITIAL TEST,
NECESSARY REPAIRS SHALL BE MADE BY AN APPROVED METHOD. THE
MANHOLE SHALL THEN BE RETESTED UNTIL A SATISFACTORY TEST IS
OBTAINED.
REMOVED)
REINFORCEIJENT ANO JOINT
DETAIL TO BE DESIGNED BY
THE ENGINEER AND
J_
APPROVED BY THE
g"
CITY.
!
J.
'
·
41600306
MANHOLE I EAKAGE TESTS
9d' BENO
· 1--2·
'
PRE-PRIMED
JOINT SURFACES
PRE-MOLDED PLASTIC
JOINT SEALER WrTH
PROTECTNE WRAPPER
(WRAPPER TO BE
BENCHING PER SPECIFICATIONS
1.
2.
'
(SEE NOTE 2)
=::::::::::==ilt'====tWRAP JOINTS
BEDDING ROCK
..
.
TRANSITE COLLAR ENCASED
IN NON-SHRINK GROUT
FLUSH WITH MANHOLE WALL
0
5"
.
PRODUCT NUMBER
OR STORM IMPRINT
CONCR~A[N~~EMENT
OF VE
DROP PIPE
(SEE NOTE 1)
STANDARD DROP DEl'AIL
BEDDED IN MORTAR
~
4°- 0"
·
2 COURSES OF BRICK MIN.
4 COURSES W.X.
:'.]
EPOXY COAL TAR COATINGS
PER SPECIFICATIONS
.'
.
·
· d:
....
INLET CONNECTION
AS REQUIRED -
IN FLUENT SEWER
{SEE NOTE 3)
I
""'·" ~ '
NOTE:
COVER TO INCLUDE SANITARY
'I
'
'
SET COVERS FLUSH IN - - --PAVED AREAS &: AT
ELEVATIIONS SHOWN IN
UNPAVED AREAS.
TEE
I
, I·
~
2
J6
42 4B 54 6D 66 72
Time , in seeo"ds
14 17 20 23 26 29 JJ
IB 21 25 29 J3 J6 41
21 25 30 l5 39 4J 49
25 30 35 41 46 51 57
29 34 40 46 52 5B 67
32 38 45 52 59 65 7J
35 42 50 53 65 72 B1
39 46 55 64 72 79 89
42 51 59 64 76 87 97
46 55 64 75 85 94 105
49 59 69 61 91 101 11J
SJ 63 74 67 98 108 121
'~o J
25
JI"
DIA.
_r1
llEFERANCE INFORMATION
4160031 0
41600320
JI"
1£2'.C'.'. (Eii/' ::::::c?-r
FRAME SECTION
26WDIA. ~
p:l'F/
25
··
MANHOLE CONNECTION DETAILS
I
DIA.
~N
2·· 01A.
~25
JI"
.
~L£:.
OIA. -----1
"n6"1
11
~
PICKHOLE DETAIL
'/ DESIGNATES MACHINED
SU Rf ACE
L - - .32 }fin DIA. _ _ _ j
NOT TO SCALE
PRECAST CONCRETE MANHOLE
PLAN AND SECTION
RING SECTION
llltiEN OROERING, SPECFY 10P FL.AHGE
OR
'
I,.
:;I
!~
'1
I
··1
''
''
.J'
'"
'
z
CONCRETE ENCASEMENT
(SEE {g) CONDITION /12)
"
-./1~
w
t~
,.
:J
METALLIC LOCATING WIRE
CAP
?.!://
·' '
/.~·/
. ,v- "'-//
" / ~ '\~\
\
6~
PVC
wYE
NOTES:
PVC PIPE SHALL REQUIRE INSULATED METALLIC LOCATING WIRE
( 14 GAUGE COPPER) CAPABLE OF DETECTION BY A CABLE LOCATOR
AND SHALL BE BURIED DIRECTLY ABOVE THE CENTERLINE OF THE PIPE.
LOCATING WIRE SHALL TERMINATE AT THE TOP OF EACH VALVE BOX
ANO BE CAPABLE OF EXTENDING 12n ABOVE TOP OF BOX IN SUCH A
MANNER SO AS NOT TO INTERFERE WITH VALVE OPERATION.
USE DUCT TAPE AS NECESSARY TO HOLD WIRE ON THE
TOP OF THE PIPE.
ALL SPLICES SHALL BE MADE USING A WATER-TIGHT SEALING
METHOD APPROVED BY THE CITY.
SET TOP OF VALVE BOX
TO FINISHED GRADE
I
COLLAR
IN ,,UNPAVED 6REAS
24 01{!. X 6 THICK
~--CONCRETE
--~
!
f/1rOfiL)B(~Ef2~J"AJ)
FINISHED GRADE
~
'6
~
!'
6" PVC
'
!""
SEWER'
M~N
L=. !SEWER
t..-::.--~~
.
r::----
CONCRETE ENCASEMENT
(SEE (g) CONDITION f2) ~
'
.
WATER MAIN
-- -
0 ·1
L~_j_.:.-=-J
4" MIN. (TYPICAL)
;;;.
fil
~
~
SECTION {CROSSING)
~
«
iIi:
w
!
~
SEWER LATERAL DETAIL
:.
NOT TO SCALE
~
0
0
~
i
I
I
~
~
~~
---~~
~~~
----li--E_C_H_N_l_C_A_L________.,._________P_V_C_P__IP_E__L_O_C_A_T_l_N_G_________::·0-~~-,~~0 .t-~i!ir"tc-';";;;~i
~~
---~~~
----li--E_C_H_N-IC__A_L________.,.__________S_E_W__E_R_LA
__T_E_RA---L----------~00i~~·~~.;;i~,-,~:c;R;;;~~.
i
5
g
~
~
I
BITE:
l«k
30APR07
5
OF
S-5
20
~
SEWERS ANO FORCE MAINS SHALL BE LAID AT LEAST TEN FEET (OUTSIDE TO OUTSIDE) HORIZONTALLY
FROM WATER MAINS.
PROVIDED THE APPLICANT DEMONSTRATES THERE IS NO REASONABLE ALTERNATIVE, THE CITY MAY
APPROVE SMALLER HORIZONTAL SEPARATION DISTANCES FOR SEWERS IF ONE OF THE FOLLOWING
CONDITIONS IS MET:
1. THE TOP OF THE SEWER IS INSTALLED AT LEAST 18~ INCHES BELOW THE BOTTOM OF THE
POTABLE WATER LINE.
2. THE SEWER IS ENCASED IN WATERTIGHT CARRIER PIPE OR CONCRETE.
3. BOTH THE SEWER AND THE WATER WJN ARE CONSTRUCTED OF SLIP-ON OR MECHANICAL
JOINT PIPE COMPLYING WITH PUBLIC WATER SUPPLY DESIGN STANDARDS AND PRESSURE
TESTED TO 150 psi TO ASSURE WATER TIGHTNESS.
SEWER ENCASEMENT DETAIL
i
~
~
O
DETAIL
S TANDARDS
MANUAL
§
TECHN ~?:;F~~~~A~~~1o~ANUAL
I-
BITE:
30APR07
~
S-6
5
~~
~
:;:
i!z
w
DETAILS
TECHN~?:;F~Jr.~~~~~~!1o~ANUAL
I-
1111~
~
~
~
~
1-
=:>
>-
~
Q:'.
5
~
I-<(
~
~
::'
Z
i
(/)
~
'"
NOT TO SCALE
1;
z
!j
0
~
~
(j)
>
0
~
~
I
I
i~
~
l-
JOAPR07
~
__J<(
S-14
5
Q..
0
en
i
~
~
0
~~
--~~
~~~
----li--E_C_H_N_l_C_A_L________.,._________S_E_W_E_R__G_A_T_E__V_A_L_V_E________-.~00-~~-~~t';-i!iit~-':-";;;~i
~
i="m~~~'~"~'~'~'~-_, o
S-7
B
JOAPR07
I
i
15
~~
---liii
~~~
----li--E_C_H_N-IC_A__L--------..---------S-E_W_E__R_E_N_C__A_S_E_M_E_N_T---------~~00~~-~-~~'-,;;i~r"-,:,;R;;;~~
STAN DARDS
MANUAL
I-
~
SEWER GATE VALVE AND BOX DETAIL
.
1~
!
~
;;;.
i
NOTTO SCALE
l""m=~~6_·~~"~-_, o
- (.....-------BEDDING ROCK
NOTES:
1. PVC EXTENSIONS SHALL NOT BE USED ON VALVE BOX INSTALLATION.
2. THE ACTUATING NUT FOR DEEPER VALVES SHALL BE EXTENDED TO
COME UP TO 4 FOOT DEPTH BELOW FINISHED GRADE.
3. VALVE EXTENSION SHALL HAVE SET SCREW INTO 2" OPERATING NUT.
4. ALL BELOW GRADE NUTS AND BOLTS SHALL BE STAINLESS STEEL
5. ALL VALVE COVERS TO BE PAINTED WITH EXPOXY PAINT.
WATERMAIN (BLUE), FORCEMAIN (GREEN), FIREWATER (RED) AND
RE-USE (PURPLE)
~
SECTION (PARALLEL)
~
1) PROVIDE LOCATE WIRE ALONG
FULL LENGTH OF LATERAL (SEE S-5)
---
l
SEWER
;;i.
:.
~
©
~
~
LESS THAN 18"
r-.r -
©
I
LESS THAN 18"
(TYP.)
~
TECHN ~?:;F~~~~~~~~::ANUAL
~
WATER w.IN
CAP
PVC PIPE LOCATING WIRE DETAIL
MANUAL
I
,'J SEWER
CONCRETE ENCASEMENT
(SEE (g) CONDITION #2)
~/(TYP.)
WIRE DETAIL
'
' '
_J'
i
~>>.
WATERTIGHT CARRIER PIPE
(SEE (g) CONDITION #2)
45· ELBOW
S TANDARDS
' ILESS THAN
;I 10'
PLAN {PARALLEL)
, /
4.
V)
'[J_
PLAN (CROSSING)
P.v .c. WATER MAIN
OR FORCE MAIN
3.
Ei
!.,.
z
2.
ffi
11;
b
FLANGE
I'
'.
FINISHED GRADE
eonow
1
''
I'
CONCRETE ENCASEMENT
(SEE (g) CONDITION /12)
1.
NOTE: FRAME IS REVERSIBLE.
STAN DARDS
MANUAL
AND BOX DETAIL
TECHN ~?:;F~~~~~~~~~1o~ANUAL
I-
~
·"~m~~~·~1~·~·~'~'~-~'
BITE:
·"~-,~,,~.~"-~'''~~:c:~::--~~~~~~~~~~....~~~~~__,®
''il:C:''<:'it"!Or!!l::'l"'1!~11:'>!!!l!"l'l:l:'l!rll"'!:::l'"!l!'lii:~~!l!O'TB:l:n::C:::--~~~~~~~~~~
....~~~~~__,®
''l::'::'Tn!lr!!""'::'i'r.lll:'>~'l":l:'ll"ll"'!:::ll"!l!'lii:~~!l!O'TB:l:n::'l::'"""~~~~~~~~~~
....~~~~~__, ®
''=''0::'1l"lli!"!:o:::11:"1"l::l,.,,!mil"l"::!"ll'll"'!:::l'r'!O!!rn~=:11"l!'l"l::n::C::--~~~~~~~~~~
....~~~~~__, ®
(/)
Dobo:
"24Po> Uoot
.Jell
Oo1t:
.l;l.,_ U.le9
S"ooiLd"'l
Colo:
!.Iott !ti. (.-.!Rio:
Eoal>'do
lJolo;i _
_...
E.........
REV
~
ll lel17.
DATE
10:
~lll!Fllo:
P:\0,, 1! 8 8-io..........
BY
Sil ~
llo,.., 11
C MLJOF~
...,.. , ,.
~
REVIS IONS
.._ ,, _
_,
lloy ll .lllll ·
SCA LE ~
R~:::~
Ilk
"""4Fll~
P: Jili-8 Effio"O.
Sil- -
I
tlii~F
....
AS NOTED
:: :::
DESIGN ED BY:
JHS
·I· l'lll-9 11o1o;1
.::PANHANDLE
ENGINEERING, INC,
llo)" ll 2011. l:24ptto
P:
16-ll
.)1111 Sil- -
I CM.lllio
.....
l)olo, llo)
lHI
1l 1011.
~
...... ll1 SrnlFllot P: 57111HI
'ii)- -
1 CMLXFo
~l'lli-!I [Mio~ ~
.....
James H. Slonina. P.E. 39197
SANITARY UTILITY DETAILS
ANDREWS PLANTATION SUBDIVISION
~~:::~:~:~:~£~;:::i'"'"
77 0
"'*"c""~""' '' °'
....
W
SHEET NUMBER
19
57916 B
PROJECT NUMBER
i:"
~
~
0
ISSU E DATE:
MAY 2017
----~------~--~-------------------------------Of------------------------·
ENVIRONMENTALENGINEERS · CMLENGINEERS . LANDPLANNERS
3005 South Highway 77 Lynn Haven, R orida32444
LYNN HAVEN
FLORIDA
.
1
~
:
ID
~
en
NOT
RE LEASED FOR CONSTRUCTION
BY:
DATE :
ACAD FILE NAM E: 579 16-B Detai l Sheets.d wg
(850)763-5200 Fax(850)769-0730 pe@panhandleengineering.com
QPR CERTIFI CATION #EB-7806
.
t-"'"'. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .L!"J
@ PANHANOLE ENGINEERING. INC. ALL RIGHTS RESERVED. NO PART OF THIS DOCUMENT MAY BE REPRODUCED OR UTILIZED IN #N FORM WITHOUT PRIOR WRITTEN AUTl10RIZATION OF PANHANDLE ENGINEER!NG. INC.
FOR SCALE VERI FICATION AFTER DUPLICATION, TH IS LI NE SHOU LD BE l" LONG
LEAKAGE TElITS
LINES SHALL BE TESrED FOR LEAKAGE BY LOW PRESSURE AIR TESTING, INFlLlRATlON TESTS OR
EXFlllRATION TESTS, AS APPROPRl,6.TE. LOW PRESSURE AIR TESTING FOR VITRIFlEO CLAY PIPES
SHALL BE AS PRESCRIBED IN ASTM C 828. LOW PRESSURE AIR TESTING FOR CONCRETE PIPES
SHALL BE AS PRESCRIBED IN ASTM C 828. LOW PRESSURE AIR TESTING FOR PVC PIPE SHALL BE
AS PRESCRIBED IN ASJM f 14 17 AND PRESSURE DROP I IMITS SHA! I BE OEifRMINFD BY USING
A.SIM E1417 TABLE I SHOWN BEL.OW. LOW PRESSURE AIR TESTING PROCEDURES FOR OTHER PIPE
MATERIALS SHALL USE THE PRESSUR ES AND TESTING TIMES PRESCRIBED IN AST\1 C 828 AND AS1M
C 924, AFTER CONSULTATION WITH THE PIPE MANUFAClURER. PRIOR TO INFILlRATlON OR
EXFlllRATlON TESIB, THE TRENCH SHALL BE BACKFlu.ED UP TO AT LEAST THE LOWER HALF OF THE
PI PE. IF REQUIRED, SU FFICIENT ADDITIONAL BACKFILL SHALL BE PLACED TO PREVENT PIPE
MOVEMENT DURING TESTING. LEAVING THE JOINTS UNCOVERED TO PERMIT INSPECTION. VISIBLE LEAKS
ENCOUNTERED SHALL BE CORRECTED REGARDLESS OF l..EAJ~
~
~h nme for
Min.
I
i
Dia., Tl!"e. Minimum L.anger L
in. mm:e nmco, ft. lenQth,e 1CJ!l ft. 150 ft. 200 ft. 250 ft. JOO ft. 350 ft. 400 ft. 450 ft.
4
J :46
597
0.380 L
3:46
5:40
JllB
0.854 L
5:40
7:J4
9:26
11:20
14:10
17:00
19:50
22:40
25:30
28'20
31:10
34:00
298
239
1119
159
133
114
99
L
L
L
L
L
L
L
7:34
9:26
11 :20
14:10
17:00
19:50
22:47
28:51
J5;J7
43:05
51:17
10
12
15
18
21
24
27
30
JJ
J6
1.520
2 .374
3.418
5.342
7.692
10.470
13.674
l:l7.306
21.366 L
L
25.852 L
"80
72
66
30.768 L
J:-46
5:40
J :46
J :46
J :46
5:40
5:40
5:40
7:34
7:34
7:34
7:36
9:26
9:53 11 ;52
9:26
11:24
14:15
17:05
11 :20
14:10 17:48 22:15 26:42
19:13 25:J8 J2:03 38'27
26:10 34:54 43:37 52:21
J4:11 45:34 56:58 68:22
57:41 72:07 86;J2
43:16
5J:25 71 :1J 89:02 108:50
64:J8 86:10 107:43 129:16
76:55 102:34 128:12 15J:50
D0224 1, SDR- 26.
2.) PVC PIPE GREATER THAN 12" SHALL BE AWWA C905 (DR25}.
3.) FITIINGS AND VALVES 4H ANO GREATER SHALL BE MECHANICAL
JOINT DUCTILE IRON (250 PSI MIN.) WITH CEMENT LINING.
4.) ONE BOLT OR MEGALUG RESTRAINTS SHALL BE UTILIZED.
(FOR INFORMATION ON ONE BOLT CALL 1(205)739- 0010 OR
OR Go TO www. o nebolt.com)
5.) ALL FORCE MAINS SHALL BE COLOR GREEN OR BROWN .
6.) ALL SANITARY FORCE MAINS SHALL BE HYDROSTATICALLY TESTED
PER AWWA STANDARD C600 (LATEST EDITION) AT 100 PSIG
(MINIMUM) FOR TWO HOURS.
7.) ALL FLUSHING REQUIREMENTS PER AWWA STANDARDS (3 fps
MINIMUM., 2 X PIPE VOLUME MINIMUM.}
8.) FOR 2~ FM AND BELOW SERVING PRIVATE LIFTSTATIONS USE
HOPE SDR-1 1 TUBING FORCE MAIN ANO APOLLO BRONZE 400 PSI
THREADED BALL-CONE INLINE CHECK VALVE MODEL CVB WITH APOLLO
BRONZE BALL VALVE 70-100-BC SERIES (OR APPROVED EQUAL).
THIS ASSEMBLY SHOULD BE INSTALLED IN A STANDARD METER BOX
AT PROPERTY LINE.
9.) DUCTI LE IRON GRAVrTY PIPE, DUCTILE IRON FORCEMAIN PIPE AND
FITIINGS TO BE LINED WITH PROTECTO 401 CERAMIC EPOXY IN
ACCORDANCE WITH ASTM A716/A746.
~
Sp..:ffioation Tim· for t..ngth (L) Shown, mtn'l
6
8
1.) PVC PIPE 4" TO 12· DIAMETER SHALL BE ASTM
'5
''g
TABLE 1 MINIMUM SPECIFIED TIME REQUIRED FOR A 1.0 PSIG PRESSURE DROP FOR SIZE ANO
LENGTH OF PIPE INDICATED FOR Q- 0.0015
NOTE 1 - SEE PRACTICE UNl-8-6-90.
NOTE 2 - CONSULT WITH PIPE ANO APPURTENANCE MANUFACTURER FOR MAXIMUM TEST
PRESSURE FOR PIPE SIZE GREATER THAN 30 IN. DIAMETER.
Pipe
FORCE MAIN
J:46
J :46
J :46
5:40
5:42
6:24
8:52
10:08 11:24
13:51 15:49 17:48
19:56 22:47 25:J8
3 1:09 J5:J6 40:04
44:52 51: 16
57:41
81:00 69:48
78:31
79:46 111 :10 102:JJ
100:57 115:22 129:48
124:38 142:26 180:15
150:43 172:2 1 19J:5J
179:29 205:07 230:46
I
II
''~
GRAVUY SEWER
~
I·
1.} PVC PIPE 4"-15" DIAMETER SHALL BE ASTM 03034, (SDR-35.}
2.) ALL SEWER LINES SHALL BE COLOR GREEN OR BROWN.
3:) All. GRAVrTY SEWER PIPING SYSTEMS SHALL BE TESTED IN ACCORDANCE
WITH ASTM C-828 FOR CLAY PIPE, ASTM C-924 FOR CONCRETE PIPE,
ASTM F-141 7 FOR PLASTIC PIPE AND ASTM 0-1 244 FOR CONCRETE
SEWER MANHOLES, EXFILTRATION OR INFILTRATION TESTS SHALL BE
PREFORMED WITH A MINIMUM POSITIVE HEAD OF 2 FEET. THE LEAKAGE
EXFILTRATION OR INFILTRATION SHALL NOT EXCEED 200 GALLONS PER INCH
OF PIPE DIAMETER PER MILE PER DAY FOR ANY SECTION OF THE SYSTEM.
4.) FIBERGLASS OR STAINLESS MANHOLE COVER INSERTS ARE REQUIRED
AT ALL MANHOLES WITH RIM ELEVATIONS BELOW 7 FEET NGVD.
5.) MANHOLE RINGS AND COVER SHOULD BE 3 INCHES ABOVE GRADE IN
UNPAVED AREAS TO PREVENT STORMWATER INFLOW.
6.) AFTER CURBING ANO PAVEMENT CONSTRUCTION PROVIDE TO CITY FULL
VIDEO OF MANHOLES & GRAVITY PIPING (MAINS & LATTERALS) ON COMPACT
DISK. ALSO INCLUDE TEXT REPORT. THE CrTY RECCOMENOS THAT PRECURB/PAVEMENT VIDEO BE PERFORMED FOR CONTRACTOR Q.A.
l
~
~
!'
~
I
'~
'
l-~
~--~~~-~~~li~E-C_H_N_l_C_A_L~~~~~~~~~~~G-R~A-V-IT~Y-S-E~IN-E-R~~~~~~roo-~-,~-:~i-:W-,-,R~--11
S TANDARDS
NOTES
OF 20
i~.Th~·J18l"''°i""~R~oE'=:=I~,
!«),
TECHN ICAL STANDARDS MANUAL
~
1l
M AN UAL
S-18
....,,.,,.,..,,....,,.,,,.,,,,,.,,..,,..,.,,............,,,,...,j!i==::.....,,,,.,,,,,,,,....~~~~~~~~,__~"-"~--'®
DEfAJL
CITY OF LYNN HAVEN FLORIDA
-Do.., ~ 11, 2017, l2'1!"'1 llw ID: ~m2Fl0. 1':\>1&11 B """"'°Jee IV- - \! CMLJDF~- .,-..·"'111\01&1&--& o.t.il ~
REUSE
HI~
RE
A
GATED
IT~ RECLAIMED
WA TER~
DO NOT ORI~~
HYDRANT
1 n POLYETHYLENE
200 PSI TUBING
NO..,,§,.EaERJY
NOT FOR
flRE PROTECTION
z
<
r1· PVC
='===!@]I==='==
~.
FORD DOUBLE STRAP
TAPPING SADDLE
_/
AWWA TYPE
CC THREADS -
(+) IRRIGATION SERVICE METER
PLAN
z
(*) BOXES BY CITY FOR 2"
LINES AN O SMALLER
/ ,'
~
~
FORD DOUBLE STRAP
I
CITY --~+I~·-1PRIVATE
MAINTAINED
I
MAINTAINED
,,.
'
,J/
/ , ,_
'
(i~hl-myt6~Tl~GBl~?RE'
SEE NOTE 6)
30"-45'
_,_~::>~ _ _l____ ___ ___
"'
-
;;i:
~
!
NOTE
RE-USE IRRIGATION SERVICE METER
TO BE INSTALL ONLY WHEN REQUIRED
BY THE CITY.
RE-USE SERVICE DETAIL
;;i:
SEE NOTE J
~
I
~
~
~~
-~!iii
~~~
~~~li~~~~~~~~.-~~~~R-E___U_S_E_S~E-R_V_IC-E~~~~.....~..-. .-,.~-Rc-,,,-c~-1,!
1-~........~~~~~~~~~-.-~~~~~~~~~~~~~~~-.-~~~~---1!
00
~~·;~·=:!R[~
e
1--..
S TANDARDS
TECHN ICAL STANDARDS
MANUAL
DETAIL
M AN UAL
·.
CITY OF LYNN HAVEN FLORlOA
~1-""·c~·:::r'°~'~"~"t'=::::I'
r'
!«),
1 OF 1B
0
DETAIL
~
R-1
"
"'!.:.~.,::-,;..~.~"~·.~..
c::l~
=i"~'~,.~"'~'~''io;o",.-..~-=·~~n.~~.~.="~'~"~~~·:'l=.~.,~m"~'~~=·~',_,.,::;:-------------''-------- 0
M
S TANDARDS
ANLJAL
1-J>~~·~~·::::JR~RfJ,~':"
'::;:=:J,i
3
7
RE-U SE SERVICE
T EcHN ICAL
TECHNICAL
STANDARDS
MANUAL
CONN ECTION
DETAILS
·.
CIT'( OFLYNN HAVEN FLORIDA
i="m
=~~'-·
~~
13~·_
I-
e11.TE:
"'!-:.~..::i;,.,.m,,~.·~,..
l::'l~
=i,.~~
<::l"co~,~.,,~.m..-..T..~::.,.n.~-=.,,~.m"~~~·=:=
· ·=,.~.,~m,.-..,~~=·n,==·~-----------.._
~
_, ,
aETJ\JL
oAPRo
~
______.,e
R-2
"
DRINK
J1J'
..~ IS
f'~] I ~· ·
.
t:::I
~
~
BEDDING ROCK
.o-JQ)
z
Q)
f;i:\
~
~
(/)
\l:!Y
'
(/)
!
;::UJ
.r=,
~
§
I
~
CONCRETE COL!.AR IN
,
PRE~ TO BE 2J 1/ 2" DIA.
~
~~~4 LN~~E(:E~OTE
~
UNPAVED AREAS
_
OR
0
~
"'
1:::i
-
W
,.
~
....J
~
o?5
,,.
24"·24"x6" THICK
7)
ll;~:j~
~~~HO~TEE
~
~
~
u...
~
AL~~OSEAJx GATE
(SEE OETAILf
g
>0::
!
;::
!"§
Z
~
(/)
!i:
Z
Q
_
<(
i
2. THE 000..0PER MAY INSTALL THE SHEAR PAO 'RECESSED UP TO
4 INCHES BELOW FINISHED GRADE AND SOO lHE RECESSED SECTION.
3. CLEARANCE ' 9ETWEEN SO'TTOM OF BOLTS AND TOP OF SHEAR PAO
SHALL BE A 6' MINIMUM.
4. N'PROVED HYDRANT MODELS ARE AMERICMI DAALING 8-84-8,
M+H A-129, &: Al/K. NO SUBSTTTUTlONS WILL BE ALLOWED.
5. EPOXY PAINT HYDRANT PANTONE 522-C
6. ATTACH SIGNAGE SELECTED IJ'I' CIT'( AT PUMPER NOZZl.E.
7. ALL VALVE COVERS TO BE PAINTED WITH EXPOXY PAINT.
WATERMAIN (BLUE), FORCEMAIN (GREEN), & RE-USE (PURPLE)
~
~
-
NOTES:
!i:
~
N
1. HYDRANT Stwl. BE SUPPi.JED WITH A WEEP HOLE.
i
1-
-
M J ANCHORIN"
COUPLING
1~
I
ECHN ICAL
,.
§er
~
8 ®
O
<~
!
1-
f;i:\
BACKFILL~___/,
,~
~
0
NO BEBA
SWIM
SEE
fil
~
0
NO MADE
NO BEBA
@~
~
COMPACTED
NO BESA,
JbuN'rf------......... ".,
~
~
HEAR PAD
~
~
DO NOT
6NOTE_ 1.12 AT 9· "
~
!i:
DO NOT
REl~~ORCED. c~iti~,.
~
DO NOT
1r:;;~
~
~
;
~~::5
~
RE-USE SERVICE CONNECTION DETAIL
SCHOOL
H'IDAANT
>
7. NO SERVICE LINE SHALL TERMINATE UNDER A DRIVEWAY.
B. EACH SERVICE SHALL TERMINATE AT A CURB STOP WHICH SHALL
BE BURIED APPROXIMATELY 3" BELOW FINAL GRADE AND SHALL BE
CLEARLY MARKED WITH A 2· X 2· X 18· STAKE WITH THE TOP PAINTED
PURPLE AND MARKED WITH THE NUMBER OF THE LOT TO BE SERVED.
DRINK
NOT TO SCALE
1
6. PROVIDE #14AWG LOCATOR WIRE ALONG ENTIRE LENGTH OF TUBING.
NOT
RECLAIMED WATER
IN USE FOR
IRRIGATION AT THIS
JYPICA!. REUSE SIGNAGE
i
PROVIDE INSERTS AT All. CORPORATION ANO CURB STOPS.
oo
\l:!Y
~
LOCKABLE TYPE FORD GR IP SEAL
RECLAIMED WATER
IN USE ON COURSE
DRINK
!
4. ALL CORPORATION STOPS SHALL BE FORD GRIP SEAL,
§i"'
SECTION
IJ:!Y
fj
g
RE-USE MAIN
~
NO BEBA
5.
~
SPORTS PARK
DO NOT DRINK
-
~
""
IN THE LYNN HAVEN
FOR IRRIG·TION
'
~· :E:::~:E::~~:~L p:~
~
SUB-DIVISION
~
~
1
,.
BRASS STRAINER ASSEMBLY (NOT BY CITY)
{STRAINER TO BE CENTERED UNDER
METER BOX DOOR}
.........
RECLAIMED WATER IN
USE
TO METER
BOX ASSEMBLY
'. ~TE,S~NGS SHALL BE BRASS WITH COMPRESSION/PACK JOINT
<
"'
~
25 LB. BRONZE GATE VALVE
W/RISING STEM ( NOT BY CITY)
o '
-
!
,,,.
K
,,_
'(,=
' ~
5
,
-...
'
WATER OR
REUSE MAIN
5
:
"
.;"
TAPPING SADDLE
'
I
I
_ . ,, . . , _ , , _
·'
RECLAIMED WATER
USED FOR
IRRIGATION IN THIS
NOTICE
1~ FORD GRIP SEAL
CORPORATION STOP
"'§!
.,,.,,
~
0
v .>
>
1-
~
0
CO
i~
l-
~
REUSE HYDRANT ASSEMBLY PEIAIL
I
NOT TO ' " "
~
0
1-~........~~~~~~~~~-.-~~~~~~~~~~~~~~~....00~~~~---1,,'
e. "TEc~ICAL
;::
>..~~"~1c~=:!:~J'!~';;"::;:=:J·
WATER ANO REUSE
Z
(~~~~~~*~~·-~~~~!;~~~~~~~~~R~E~U~S;E~H~Y~D~R~A~N~T~:~~--JI-~"~'"~·i"~'~'~'~"~' j!
t!'l
~
Colo,..,, 11. 2011. "
'"" ...,
("'2Rio'. p,
16
_.,, . . Sil _ , ,
i=
" m~~~'~'~"~'~
"~--1 '
NICAL STAND ARDS MANUAL
!;ll'Ullfo~
DETAJL
R-1 8
CITY OF LYNN HAVEN FLORIDA
. -.
11-e .. ·1_
_...
_J
~
,....
<(
"
1...1..
0
'iiiiii·®""'"·'·'·'iiilii"·'l'·"·'·'·"·'·"·'"""'"·w·~iiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiii. .iiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiii'W'iiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiii4'.S:
............................., . ......................................................................................................, . .................................................................................................................................................................................
REV
DATE
BY
SCA LE ~
REVISIONS
R~:::~
AS NOTE D
:: ::
DESIGN ED BY:
JHS
.::PANHANDLE
ENGINEERING, INC.
W
James H. Slonina. P.E. 39197
SANITARY & REUSE UTILITY DETAILS
ANDREWS PLANTATION SUBDIVISION
~~:::~:~:~:~£~;;'f:i'"""
"'*"c""~'""'''"'"
SHEET NUMBER
20
57916 B
PROJECT NUMBER
"'
~
ISSU E DATE:
MAY 2017
ENVIRONMENTALENGINEERS · CMLENGINEERS .
LANDPLANNERS
LYNN HAVEN FLORIDA
~
:
ID
~
~
--~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~-Of--~~~~~~~~~~~~~~~~~~~~~~·
0
"'"'. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . L()
NOT
RELEASEO FOR CONSTRUCTION
BY:
DATE :
ACAD FILE NAM E:
57 916-B Detai l Sheets.dwg
@PANHANDLE ENGINEERING, INC. AU.R IGHTS RESERVED. NO PART OF THIS DOCUMENT MAY BE REPRODUCED OR UTILIZED IN #N FORM WITHOUT PRIOR WRITTEN AUTl10RIZATION OF PANHANDLE ENGINEERING, INC_
3005 South Highway 77 Lynn Haven, Flo rida32444
(850)763-5200
Fax(850)769-0730
pe@panhandleengineering.com
J
DPR CERTIFI CATION #EB- 7806
.
-
O>
,...._
FOR SCALE VERI FICATION AFTER DUPLICATION, TH IS LINE SHOULD BE t" LONG
·
0·
···
ii:,(
POWER DISCONNECT
(SWITCH TO BE NEMA 4)()
GALVANIZED
PIPE CAP
_
MALE
PINS
(TYP.)
wttx4ttx1/4"
F~l£~D 0~UMINUM
0
~
''
'
i'5'
0
:·
'
0
~
' ,.,
''
'
·
.,
i! ..
- ·
' I·
·
··
·
~
:s
'
· -:G
' ''
· .,·"
-··
-'
-··
'
FEMALE
CASE
-
0
~:(
.
~;---::0it::~;L:;:1_..~l$
WITH
MmRBY-PASS
BASE
1J$:"X1J!i" MIN.
MOUNTING BRACKET
(GALV. UNISTRUT CHANNELS)
12 GAUGE
GENERATOR RECEPJACI£
MANUFACTURE: RUSSELL STOLL
MOOEL: #JRSB1044FR
CONTROL
PANEL
100 AMP PANEL MOUNTED WITH 20
DEGREE ANGLE, 4 WIRE, 4 POLES
WITH REVERSE SERVICE
-N
Wl-t-tt--SEAL OFF
MOTOR COtjDUCTOR
CONDUIT 2 SCH. 80
PVC (SEE NOTE 2)
U-BOLTS 3/8" MIN
ENCASED IN
CONCRITT
·
8 ·~
!
!
'
1
2
' -,'
SWEEP
1.
2.
.3.
4.
5.
6.
8
B
.
:lg;
' .,' ·
i,!
il
.
l
45 OHM MAX. GROUNf RODS
(2 EACH) (10' APART
·
NOTES:
DRAWING IS SHOWN FOR 2.30 VOLT POWER SUPPLY. THE LOCATION OF
MITTR AND MAIN POWER DISCONNECT SHALL BE REVERSED FOR 480
VOLT SUPPLY.
'WHEN TWO (2) SEPARATE CONDUCTOR-TYPE MOTORS ARE USED, CONDUIT
SHALL BE INCREASED TO .3".
POWER SUPPLY SHALL BE UNDERGROUND Of" THE LIFT STATION SITE
ANO SHALL BE 3 PHASE FROM A 3 PHASE SOURCE ONLY.
CONTRACTOR TO VERIFY AVAILABILITY OF 3 PHASE
POWER BEFORE ORDERING EQUIPMENT.
PROVIDE 2" CONDUITS FOR FLOAT LEADS ANO EACH MOTOR LEAD.
CONDUIT SHALL BE SCHEDULE 80 PVC.
§f-o
~r-o
t·
t·
'·
.
'"
,! .
'
·
:!!
'°
5E1TMCE
A.II?
WIRE 8 ~ TIJl[J: 0
GOl-OUNO "IRE 6 NJIC Tl~
TffiMINllL. 1
6 A'llG
6 A'llG
TilllLE 0
TllBLE 0
Trnt.llNAL 3 6 A'llG
llTilllLE C
TllBLE C
TERt.11""1. S
TliSLE C
T~I-
~
2
e A'llG
'
&
'
Dolf< M.,,
II),
~
11)11, "241""' L!oe< Ill; ~"'2Fl0: p,_ 1911-9 EoMdo l89 1lll- -
1 C MLJDC~
XlCXX
XlC:ot
WLT.'.GE
2JOV
H.P,
#1JHP #2JHP l3X
PH.'ISEJ
F.U..
9'\
TOTAL F.L."- Z7~
SE/II.IL f
03-
'
;"ii' 79!11--6 0...11 ~
&
S TANMDARA~'~UAL
''
':1111··
,.~
t - ORB DUPLEX RECEPTACLE BREAKER
s~~
!I
I
~
LOCK FOR OEAO
II
FllONT
..'
~
111 !~ . . .;:,··~'i!1:;.;:j.p::::::::t~=!==.=:::
8 9 -
10 -
t1 -
12
1J
14
15
16
17
0 L£AD
6
HZ.,
~ ,,~ 1...
-1-§
~
.'
·
~
I
I
e
_
DR DUPLEX RECEPTACLE GFl
ASB ALARt.4 SILENCE BliITON
AH Al.ARM HORN
AL ALARM LIGHT
GR GENERATOR RECEPTACLE
PAM PUMP/ALT/MANUAL. SWITCH
PL9 POWER ON
PL10 LOW MEG I
PL11 LOW MEG 2
MOUNTING BRACKETS
A. HIGH LIQUID LEVEL AS SENSED BY FLOAT SWITCH
El. LOSS OF MAIN POl'f£R
C. POWER MALFUNCTION (PHASE/VOLTAGE)
DUPLEX CONTROL PANEL
Et::lQLQS!.!BE QE60 EBQt::lI LAYQlJI
8&NJ"ffi'omNctYoUT
NOT TO SCALE
1-
ll'lf:
-
APR o
5
. Pl-WlE:
SOI.JO SIZE:
~
PUMP STATION DETAILS,
S
PLANS, S ECTI ON, AND NOTES
TECHNICAL STANDARDS MANUAL
CITYOF LYNNHAVENFLORIDA
0
'
"~..~~~:~:'""""j,i);l'l;/'.;":'';_'~,
I-
MIT:
30APR07
~
oETAJL
~
LS-3A.2
~
~~~~'~A~·t:~e'C::=l '
·=·,~,
Dolo<
Endo.- F.0-· CMLJOF
.... ,.
.
- .:-:::.,: ------------.._______..,.,
'"IO:"<:'r.or-OJ::'ll:T.0!!!:->1!!!0m::c::""'l!"'=':m.t:~=-:1«·-m,.~.~
ENCLOSURE DEAD FRONT LAYOUT
TECHNICAL STANDARDS MANUAL
CITY OFLYNN HAVEN FLORIDA
STANDARDS
MANUAL
llo!o<
,.
*
*
·*
*
*
*
21.0
B
C
D
E
F
G
H
K
lloJ 1!, 2G!l, l<24pow U.... 0: Smlfl,.,_ P,\579111--ll """1do lllll
SI)-
-I'
C ML»'o~" -
·..,151111!
a r1o1o11
all Fllf:
llft l/f:
ll'TE:
HEIT
ij(l-.
LIFTSTATIONS
Rff
30 APR 07
2C ll" 6
~~
LS-2C
~
WIN.
UNIONS
(TO FACILITATE REMOVAL FOR SERV]CE)
23.3
HOSE RACK FAB. FROM 1/4"X
2" F.B. S.S. FASTEN W/J 3/8"
S.S. SELF TAPPING BOLTS.
2... 5
25.0
26.0
HOSE RAC K
1" REDUCED PRESSURE BACK
FLOW PREVENTOR WATTS
9D9 OR EQUAL
... 0
FREEZE PROOF HOSE
BIB W/ WATTS SA
VACUUM BREAKER
27.42
~E:.ll2Z
SIZE:
: H.P.:
~ISCHAAGE
IN.;
'
DUPLEX CONTROL PANEL
&TECHNICAL
HOT BOX. CONTRACTOR SHALL
SUBMIT SHOP DWG.S FOR
APPROVAL
90" ELBOW
4w SCH. 40 GALV.
STEEL PIPE W/
CAPPED TOP
(TYPr.)~~i
CU~;
tfI 3
· IMP:
IN.; VOLTAGE:
~11g
·
· Olk 21::imm
~
(·) METER NOT REQUIRED
IF DEDICATED TO CITY
l'-6~
GALV. PIPE
STRAP (TYP.)
'
(·) MITTR BOX
1' MIN .
~
488
1 w GALV.
PIPE
PIPE
1" GATE VALVE,
( · ) METER ANO MITTR BOXES
BY CITY FOR 2w LINES AND
SMALLER
!~
l
'fil
g
'
LIFT STATION
WATER SERVICE DETAIL
I
'
1" GALV.
NOTE:
INSULATE All. ABOVE GROUND PIPING.
PIPE INSULATION TO BE CERTIANTEED
500 SNAP ON W/ AWS OR EQUAL
g
Q)
Q)
-"'
(/)
(/)
i
4' W/OUT CONC,
!'
~
;
''
3' W/CONC.
L_
!
~
N
!
PEA GRAVEL
I'
l
CONTRllCTOR TO
I
'"
'~'
_J
------------
-- -
-
-
~
-------'-'"--------""-.\
C/L -
~
PUBLIC R/W
i-
0
z
0
-------------------- ---------------------~----... THIS DIMENSION SHALL BE
EQUAL TO THE DEPTH OF THE
WET WELL OR AS REQUIRED TO
MAINTAIN A 5 FOOT (MIN.) BUFFER,
WHICH EVER IS GREATER .
~
c--w--~I___,,
t;::
NOTES:
1. REFER TO PLANS FOR SITE-SPECIFIC CONFIGURATION.
2. PROVIDE PUMP AROUND MANHOLE WITHIN 50 FEET OF WETWELL.
3. MINIMUM CLEAR DISTANCE OF J-1/2' SHALL BE PROVIDED
IN FRONT OF THE CONTROL PANEL. (NFPA 7D 110.26(A)WORKING SPACE).
_J
z
0
PUMP SIAIIQN SITE PLAN
(/)
>
NOT TO SCALE
0
m
~
::J
I
~
TECH NICAL
M ANUAL
3"' -
I
2
L/S
e·
· MODEL:
RPM;
(/)
z
~
1-~......~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~.....-~~~~~--1 ,,'
TANDARDS
-
M..AAM TEST
METER 1
METER 2
0
HARDWARE IN WET WELL ~ VALVE EK;IX TD BE S"DJNL.ESS STEB...
INSTAU. A 'Duck Bill.· CHECk VAi.YE BETWEDI THE VAL.YE VAULT ANO
WET 'NEU. AS SHOWN.
17. ~ TD VERIFY THAT 240V / 3 PHASE
POWER IS AV.'Jl.JilLE BEFORE ORDERING EQUIPMENT.
18. PRCMDE MOTO!I OYEFILCWJ ANtl PHASE PROTECTION.
19. PRCMOE LIGHTNING PROTECTIOl\I.
20. l'!ICMOE A FWSH VALVE TO ~UTOMATlCAU.V FWSH 11-E SUMP DURING INITW..
~TlON Of THE PUMP.
21. CHECK VALVES TO er MUELLER OR Cl.OW, KEMNEOV, MH.
22. WET WELL SIW.L BE HOPE PLASTIC LINED OR HAYE "AGRULINER" INSTALL.ED.
23. DUCTILE IRON GAAYIT'!' PIPE. DUCTILE IRON FORCEW.IN PIPE AND FfTTlNQS
TD 9E LINED WITH l'l!OTECTO 401 CEAAMIC EPOXY IN ACCOR~CE WITH
A$1V A716/A7«1.
2·· Ml. WEr WEU. SECTIONS SHI.LI. BE LEVELED. JOINT SHO.U. FIT TIGHT NtD NOT BE Fill.ED.
16.
.·- _ _ _ _ ,
MOISTURE 1
MOISTURE 2
OYER'TEMP 2
RUN LIGHT 1
RUN LIGHT 2
-UFACTIJRERS REOJIREMEHT
~=
!UC!
15. Ml.
<
I!! II;;'i11'! ~r" ~~ irI f----~.~.-
PL6
PL.8
PL7
RLl
RL2
27 -
28
29
30
J1
J2
J3
ETM1 El.APSE TIME
ETM2 El.APSE TililE
HOA SWITCH PUMP
HOA SWITCH PUMP
MINICAS 1 RESET
MINICAS 2 RESET
.~"'~,.~,,::;:":j'1i!_l',,,,''B
"Ji7L_"=:i~
30
..., "'"""'·
MIH.
~
PL.5 O'IERTEMP 1
-
6 HIGH
lJ\G
""' """-
5
-
1B
19
20
21
22
23
24
25
26
X
MErAL SHALL BE PAIKTED WITH 2 ClllTS OF EXTERIOR
... """'
: ~~ : ,
0
NOTES:
~
-.UFAClURER:
LJ
CCB CONTROL CIRCUIT BREAKER
MCB MAIH CIRCUIT BREAKER
ECB EMERGENCY CIRCUIT BflEAkER
TCB TRANSFORMER CIRCUIT BRENCEN
MB1 ~ BREAKER 1
MB2 MOTOfl EIRENCER 2
PL I OFF LEVEL
PL2 L£AD LEYEL
PL.J. LAG LEVEL
PL4 HIGH LEVEL
ENcE6'$~~
9. WET 'NEU. ANO VAL.YE VAULT COVERS SHN..I. BE ALUMINUM WITH 318 S.S. HAADWARE
NtD LOCK BAA'.:kEr. SIZE AS RBlUIRED BY PUMP w.NUFACTUlER AAO APf'Ri : ~
~I!!~~ · !
-
7 -
Etw.4EL PAINT.
2. OOERIOR WEr WELL ANO INTERIOR / EXTERIOR VALVE VAULT SH.Ill. BE COATED WITH CQl.J.. TAR.
OUTSIOE CONCRETE SURF...CES ABCM: GROUND SHN..I. BE LEFT BARE{ONE ClllT (9 MILS) ctW. TAR EPOXY TO BE FIELD APl'UEO AJ'ITR INSTALLATION.)
BASE Nm FIRST RISEJi UtfT TO BE CAST MONOLITHIC.
YAl...YE VAULT SHIU BE SIZEO TO PERMIT rJiSY REMOVAL Of CHECK VALVE:
SPINDLES WITH MINIMUM CL.EARNOCES AS SHOWN FOR 8· D14MErER PIPE
Cl.Ll.AANCES SHAil. INCREASE AS REOUIRED FOR L>RGER
PIPE SIZES.
5. VALVE VAULT SHIU HAYE .SEAi.ED FLOOR ANO DRAIN.
8. Ml. LOCAT10"'5 WHERE PIPES ENTER OR LEAVE THE WEr WELL OR VAi.YE
VAULT SHAil. BE W.OE WAlERTIGHT WITH WM.I. SLEEVE OR
NON-SHRINK GROUT.
7. EXPOSED f'IPIMG SHOULD BE THOROUGHLY COATED WITH TWO ClllTS OF TAR.
8. THERE SHAl..L BE NO Vi'ILYES OR El..ECTillDL J\INCTION BOXES IN
1·1
!:
··
I ,, . ~
2
J
4
5
6
DOOR STO? WITH
GENERAL NOlES:
1. Ml. El(POSED
0
~~~=$~\B~~l~,e
aI!] ~
DD
Ii ~
~-
*PER PUMP
I~~
BB
I I I I I 1101
1. OUTER BOX SIZE SHALL BE A MINIMUM Of 2"'°W X 36"H X 10"0 OR AS
APPROVED BY THE CITY.
2. FOR STATIONS WITH PUMPS RATED 20 HP OR GREATER, OUTER BOX SIZE
SHALL BE JO"W X 42'"H X 10"0.
J. DRAWINGS SHALL BE REVISED FOR STATIONS WITH Plil.IPS RATED GREATER
THAN 47 HP N4D SUBMITTED TO THE CITY FOR APPROVAL..
4. BOX SHALL BE NEMA 4X 14 GA. STAINLESS STEEL
5. SWITCHES SHALL BE NEMA 4X BY SQUARED OR APPROVED EQUAL
6. CONTROL PANEL SHALL BE EQUIPPED WITH A Fl.ASHING RED LIGHT WITH LONG
LIFE BULB IN GUARDED ENCLOSURE AND 8" DIA. HORN. HORN SHAU EMIT
12C D8 AT 10·. M..AAM HORN ANO LIGHT SHALL BE POWERED FROM 12V DC
POWER SUPPLY WITH BATIERY SACK-UP. PROVIDE A RECHARGEABLE SATIERY
RATED TO POWER BOTH THE HORN AND LIGHT FOR A MINlt.lUM OF 1WO HOURS
UPON LOSS OF MAIN POWER. PROVIDE CIRCUITRY TO AUTOMATICALLY RECHARGE
THE 8>.TIERY AFTER MAIN POWER IS RESTORED. FULL CHARGE OF THE BATTERV
SHALL TAKE NO MORE THAN TWEN"JY HOURS. PANEL SHALL HAVE POWER ON LIGHT,
PUSH TO TEST ElliITON FOR HORN AND LIGHT ANO PUSH TO SILENCE BUTION FOR
HORN AND LIGHT WITH AUTOMATIC RESET FOR NEXT AL.ARM.
ALARM SHALL ACTIVATE UNDER THE FOLLOWING CONDITIONS:
>-"rn~~~2A~,~;'.,~,~--c1 ~
...:"Ol..,,..,,..,..,.~"-.:.,,.""io="':::.""-.-."":'~
~=o
~c-~-"-"-~-~
~"-"-o-"-""~~~~~~.._~-'L~S~-2~A.;..~_.,, ®
,.,..,.,.,,,.,..,,...,.,
Dullo lilf 11, 11117,
ti.- ID< 1""2f1111' P,
1! -8 r..lol!t 3811
Elo"'"' I ""1LD'o
''VO ;7&111--9 Oolo'I
....
.
'H---11'·:-'i;H. :
0
~""""""""""- 3..OUTER DOOR HAS BEEN OErACHEO FOR CLARITY.3..
d __ ... ,._ ..
ENCLOSURE DEAD FRONT LAYOUT
TECHNICAL STANDARDS MANUAL
"""
""' "
"""
""'
"""
""''
""' '
""°'°"
24" ltllN.
1101
23
<;o~"-w"-w!:l~
DUPLEX CONTROL PANEL
TECHNICAL
**
A
2.5'
MIN.
24
'·
HZ&O
X
!».
DIW
DIM
DIW
DIM
DIW
DIM
DIM
DIM
DIM
0
PAO LOCK
BRACK Er
21
!illl 1111"
@~B§JB
19
JO
-
0
1-~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~-1 ~
z
1 ac- 6
::,
S TANDARDS
~·m~·:t'5"t'~'"~"~'==I\
i
CITYOFLYNNHAVENFLORlOA
"""""""""""""""""""""''""~~~~~;~L""lioo"":::~T~ETC~H~N~l=C~A~
L-S_T_A_N_D_A_R_o_s_M~A-N_u_A_L~~~"'-~-!;,'"~·-~-,~~_,,~
JI,
PANEL INSTALLATION DETAIL
0
I
'""
lmRLOCK
ORB DUPL.EX RECEPTACLE BREAKER
CCB CONTROL CIRCUIT BREAKER
MCB MAIN CIRCUIT BREAKER
ECS EMERGENCY CIRCUIT BREAKER
TCB TRANSFORMER CIRCUIT BREAKER
6 - MEI\ MOTOR BREAKER I
7 - MB2 MOTOR BREAKER 2
8 - MSl MOTOR. STARTER 1
9 - MS2 MOTOR STAR'TER 2
10 - Rl-9 RELAY 1-9
11 - Al...T ALTERNATOR
12 - MC1-2 MINICAS 1-2
13 - CC'T COf'IIBOL CIRCUIT TIW-ISFORt,IER
14 - PM PHASE t.40NITOR
I 5 - FUSE BLOCKS
16 - BOAC BATIERY BACKUP
17 - EIOAC BATTERY OPERATED ALARM CIRCUIT
111 - CPT CONTROL POWER TRANSFORMER
I 9 - TSA TERMINAL STRIP A
20 - T5B TERMINAL STRIP B
21 - TSC m1111N.OJ. STRIP C
22 - GROUND BUSEIAR
23 - SMl-2 SUEIMEG 1-2
24 - LA LIGHTING ARRESTOR
,
1-~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~--1 ,,'
:.Fl~Ll~~iATIONS
1111
H-11+-000R
LATCH
17
WAJ...J(ING
-
LAYOUT MAY VARf
..
~
!WI " !WI
'CS' ~ 'CS'
·
=
~
PUMP STATION CONTROL
w
I
'-
NOT TO SCALE
JOO li'ME
0 OFF
TECHNICAL
0
22
.!
~USRJll E R
0
@
~~~
"'"'""
!'
0
20
'
.
JJ
7
e e
"
'<.
31
0
~
1:1 ;; ::i
l ~'
. li!F
;f">
j
!- !-
15 '- '
~
32
\8
~II
·
·
··
'"
' ·.I·
'·
·I
o@;+
o@;+
Ir
·
,!!
' '
-·'
·
·
"
~ ...... . · ' · '"': . '1
, 'L~ ' '
, ,1lfilr100J1
-
NOT TO SCALE
~
'
·I
,' ' '
'
;r'· .,.:r
I
~·-~Al·~
1~ +l+r~-
!I
PUMP STATION CONTROL PANEL
INSTALLATION DETAIL
~
·
-
~~
ii}
~@
16
·
s
5
12131415
Bl
0
9 10 11
I
2
J
4
5
0
I
~
~
4
0000
0000
if~ -o
I l ~
~
I
· '·'i?·
'··Z
1--i ~.
'l
··
!
11
-w
'
'
,..
C!ll
-
'
.'..
~
3
@@@ @
POCKET-I+-
·
INCOMING
POWER
"
j
""
-II
D
0
1 2
0
PIPE (SCH. 80)
,
-
~[
·~
.. ,
·
0
1:'
i2~-
PUMP STATION DETAILS,
&TECHNICAL
PLANS, SECTION, AND NOTES
TECHNICAL STANDARDS MANUAL
CITY OF LYNN HAVEN FLORIDA
STANDARDS.
MANUAL
-
00 FU:
LIFTSTATIONS
~~
Rff
30 APR 07
""
HEEl HD: 38 OF
6
'~'
LS-38
0
~
'
1-~......~~~~~~~~~~~~....~~~~~~~~~~~~~~~~~~~....~~~~~~--1 ~
&
LIFT STATION
TECHN ICAL
S TAN DAROS
WATER SERVICE DETAIL
T ECHNICAL STANDARDS MANUAL
CITY OFLYNN HAVEN FLORIDA
M AN UAL
1
·I-~~~·~~~
~"~~'~,~~,TI~o:'~''::::=I '~
1111~ 30 APR 07
00
z
:'S
i="m~~~'~·~~'---1'
DETAOL
:to.
LS-4
Q_
"'
'l:'="!~'.!!::::',,,,,,.,...~n!'l'!
....JISln"'!::"""~o::::<:o U..
P,
SD- 1
ingo 1911-6 Drioll -""J
~
..~~...~~~~~~...~~...~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~.....~~~~~~~~~~~~~~~~~~~~~~..~~~~~~~~~~~~~~~~~~~~~~~~~~~..~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~..,,·m·,·,·,·,·,,·",·,,·.·,·,.·,,·,·,·,~~~~~~~~~~~~~~..~~~~~~~~~~~~~~~~4UJ
~
REV
18, i!G17, l:i1-4p.Tt U.., Ill'.
DATE
.fi~lo
p,_
BY
l!-a
Je9
~
1
REVISIONS
SCALE'
~IP:
1""1Fl111' P:
1' I
r..1t-.. .l8D ~ -\1
C~L!DF
AS NOTED
DE:::~::: ;,H~
REVIEWED BY
~
"'
ibt.. llo)" ll i1111, 1';;p..
ISSUE DATE:
JHS
MAY 2017
11~01,01!116-~
Doloil
~
··PANHANDLE
···
ENGINEERING, INC.
ENVIRONMENTALENGINEERS · CMLENGINEERS · LANDPLANNERS
3005SouthHighway77LynnHaven,Florida32444
(850)763-5200
Fax(850)769-0730
pe@panhandleengineering.com
1(1-_ l'"l~
~!6--(l ~do
CIYU)Fo~o
LIFT STATION DETAILS
ANDREWS PLANTATION SUBDIVISION
"m""'°"·"'·'E""'
FE;~":;:,i,£;,i;~:.~,::""
SHEET NUMBER
21
PROJECT NUMBER
LYNN· HAVEN ' FLORIDA
57916 8
0::
~
~
~
~
O---~------~--~-------------------------------lf------------------------1
*
i!"".................................................................................................................................................................................................................................................................................................................................................................. LD
0
NOT
RELEASED FOR CONSTRUCT ION
BY:
DATE :
ACAO FILE NAME:
57916-8 Detail Sheels.dwg
@PANHANDLE ENGINEERING, INC. ALL RIGttTS RESERVED _ NO PART OF THIS DOCUMENT MAY BE REPRODUCED OR UTILIZED IN ANY FORM WITHOUT PRIOR WRITTENALITHORlZATION Of PANHANDLE ENGINEERING, INC_
QPR CERTIFICATION #EB-7806
-
a:i
t---
FOR SCALE VERIFICATION AFTER DUP LI CATION, THI S LI NE S HOU LD BE 1" LONG
10' - 0" TO CENTER (MAX)
TOP RAIL
~
STRETCHER
POST
BARS ~
~
CORN ER -
·0
3883$.'-~FABRIC
I
#9
12·
J/8· ROUND
TIE WIRES
o.c.
TRU SS BARS
(SEE NOTE 1)
"'
~§i~i1F.\;;~~~-·
~
'
z
·
~
.
~
]
~
·
§
-~
·
~
-~
·
i
i
·
i
~
~
.~
~
U
~
R
~
~
.~
~
.~
~
Kg
L
~
E
·~
·
_
.
_·
~
~.
~
L
4
111
WIRE
~
TEN SION
~
w
n
'5
''
.·r1
-----+ 14-"
L··
_j 14" If..--
g
~
FENCE PETA!L
GATE
I
I
GATE CORNER
I
I
I
''~
2500 P.5.1.
~
CONCRETE
I·
14"-I
POUBLE SWING GATE PETA!L
NOTES:
1. TRU SS BARS ARE REQUIRED FOR EACH GATE SECTION ANO THE
FIRST SPAN ON EACH SIDE OF A CORN ER POST ONLY.
2. FENCE SHALL BE ZINC-COATED CLASS II
ASTM A-392, 2· MESH, #9 GA.
J. CORNER, END, ANO PULL POSTS 2-7/BH MIN. DIAM.
GALV. STEEL PIPE OR J -1 /2M X J -1 /2M ROLLED SECTIONS.
4 . TOP RAILS MIN. 1-1 / 4" GALV. STEEL PIPE. 6' GATES 12' OPENING.
'~
~
!'
CHAIN LINK FENCE DETAIL
~
NOT TO SCALE
I·
~
DllTE
RE.V
'
ioo~~,·~"~"t"5,~t~~"i10~'='=1''
l:::t:::::::t:::t:::::::::::::::::::j,_,..~~~~~~~~~~~~~~---1 ,,'
e
CHAIN LINK
T ECHN ICAL
S TANDARDS
FENC E DETAIL
TECHN ICAL STANDARDS MANUAL
M AN UAL
CITY OF LYNN HAVEN FLORIDA
111.m
I«),
3{I
APR 07
6 OF
...,,
6
DETAJL
~
LS-6
-.,rn·~·~·-:·,~~c~
=;-------------''---"""-'----' ®
Do'°'
11, 2017. l2'11"'1llw 10,
1&11- B
SD- I
''ll:::'l:;'f."iiil:'rn;::'ll:~~:"l;,lll"l"'::!'1!!''!1'""Cirnl!i>::l)=:;l!'
~
~m2Fllo
P:
~Jell
CMLJOF~
o-
""' ~- ..
N
N
~
Q)
Q)
.;::::
(/)
(/)
__J
<(
I-
w
0
z
0
I<(
I(/)
ILL
__J
z
0
(/)
>
0
ro
::i
(/)
z
0
I<(
I-
z
<(
__J
a..
(/)
REV
i:'
~
~
DATE
BY
SCA LE ~
REVISIONS
AS NOTE D
DESIGN ED BY:
JHS
DRAWN BY:
jdm
REVIEWED BY:
J HS
ISSU E DATE:
MAY 2017
0--~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~-0f--~~~~~~~~~~~~~~~~~~~~~~·
NOT
RELEAS ED FOR CONSTRUCTION
BY:
DATE :
ACAD FILE NAM E:
579 16 - B Detai l Sheets .dwg
0
@PANHANDLE ENGINEERJNG. INC. ALL RtGHTS RESERVED. NO PART OF THIS DOCUMENT MAY BE REPRODUCED OR UTILIZED IN #N FORM WITHOUT PRIOR WRITTEN Al.JlljORIZATION OF PANHANDLE ENGINEERJNG. INC_
.::PANHANDLE
ENGINEERING, INC.
ENVIRONMENTAL ENGINEERS · CML ENGINEERS · LAND PLANNERS
3005 South Hig hway 77 Lynn Haven, Florida 32444
(850)763-5200 Fax (850)769-0730 pe@panhandleengineering.com
LIFT STATION DETAILS
ANDREWS PLANTATION SUBDIVISION
James H_Slonina. P_E _39197
James M _Southall . P E _39637
Christopher B _Forehand, P _E_58028
Stephen E_ Price. P_E_ 7 1646
Jeffrey c_ Petermann , P_E. 77540
SHEET NUMB ER
sw
22
<(
PROJECT NUMBER
LYNN HAVEN, FLORIDA
QPR CERTIFI CATION # EB- 7806
57916-B
0::
0
z
ro
I
CD
~
"'
I'L!)
FOR SCALE VERIFICATION AFTER DUPLICATION, THIS LINE SHOULD BE
j"
LONG
2· x 2· x 4'
Anchor Boles W'rth 2 Stgkes Per B<:ile.
STAKED ANO ENTRENCHED
STRAW 8Al£
2X4STAKED03'±
BINDING WIRE
OR lWINE --,..._ \,
W
.µ.
;-t-- / orrc H
PROTECTION
fi,
INLET
BOTIOM
AROUND
WIRE REINFORCED
STAKED ANO TRENCHED
SILT FENCE
'r
In
INLETS
NOT TO SCALE
STRAW BALE BARRIER INSTALLATION DETAIL
/wooo
STEEL OR
NOT TO SCALE
POST
n
A II
,,'lt ___
----
\,
1§.V!I .-:fa 'i
I 11 *~
h t,.
'">%'
~~ II
WIRE REINFORCED
/
STAKED AND TRENCHED __,./'
SILT FENCE
EXTRA STRENGTH FILTER FABRIC
NEEDED WITHOUT WIRE MESH SUPPORT
'u
-------------------------------
U
---------- --~
10 FT. MAX. SPACING WITH
WIRE SUPPORT FENCE 6 FT.
t'"-MAX. SPACING WITHOUT WIRE------1
SUPPORT FENCE
NOTE:
1. INSPECT AND REPAIR FENCE 24 HRS AFTER
EACH STORM EVENT. REMOVE SEDIMENTS NO
LATER THAN WHEN DEPOSITS REACH APPROXIMATELY
ONE THIRD THE HEIGHT OF THE BARRIER.
2 . REMOVED SEDIMENT SHALL BE DEPOSITED TO
AN AREA THAT WILL NOT CONTRIBUTE SEDIMENT
OFF-SITE AND CAN BE PERMANENTLY STABILIZED.
3 . SILT FENCE SHALL BE PLACED ON SLOPE
CONTOURS TO MAXIMIZE PONDING EFFICIENCY.
CONSTRUCTION
ENTRANCE (SEE
DETAIL THIS SHEET)
WIRE REINFORCED
STAKED ANO TRENCHED
SILT FENCE
NOTE :
SEE ENVIRONMENTAL SEQUENCE NOTES THI S SHEET
AND POLLUTION PREVENTION PLAN NOTES SHEET 15
FOR MAINTENANCE AND STABILIZATION OR TEMPORARY
SPOIUSTOC KPILE AREA.
fl fYATION
NOT TO SCALE
STEEL OR
STAKED
·
AND TRENCHED ~ j----- 3 MIN. --------t
1
SILT FENCE
'\f
WOOD POST \
.36" HIGH MAX.
11
1
'
'
'
'
'
''
:' iL - - RUNOFF
WIRE REINFORCED
:vSTAKEO ANO TRENCHED
:
SILT FENCE
~~:1:Wil~"
~
II:
§'W,'1>'-'·"'
I I :v
~>$)"
~. ~ J
= '·l:·"
. ""' " l~
1
"
12
MINi
~Wv,,.vr,.
,
11
:·<-w?'
LJl.)
I
:V--
WIRE REINFORCED
STAKED AND TRENCHED
SILT FENCE
RUNOFF
(
~-$·
I
>? 1
: 1 '.('~
I
:I
:I
~~ ~v
-RUNOFF
::ii~
·;··~,"
: PONDING HT.
1
FILTER FABRIC ATTACH
SECURELY TO UPSTREAM
SIDE OF POST.
'
12" MINi :··~ ''$
LJ)
4 "X6" TRENCH WITH
COMPACTED BACKFILL
I
I,)
4" X6" TRENCH WITH
COMPACTED BACKFILL
DOUBLE ROW STAKED SILT FENCE DErAIL
SINGLE BOW STAKED SILT fENCE DETAIL
NOT TO SCALE (REQUIRED AT ALL SHORELINE,
WETLAND, AND WETLAND BUFFER AREAS)
NOT TO SCALE
I
STANDARD SILT FENCE DETAIL
EROSION CONTROL LAYOUT PLAN
NOT TO SCALE
EROSION CONTROL NOTES:
'"z
:J
~~SEENOTE0
~
EROSION CONTROL BLANKET
I
#2010-01 BY EROSION CONTROL
wl
SYSTEMS. (1-800-641-3277 ):~
UNDER SOD ANCHORED WITH
::J
6" SOD STAPLES.
SOD SIOE SLOPES
i/\ '
'
2
~
11 MAX .
ffi
a..
~,~:-,
"""~{.;,"(:}.')'.\:
:<* . . .
''<(/.''/~:· .,,
-.~.. ~~~}'.'' \.
~a.. :k,~')·
..({~~°*'*::~~~~~~w
.. .,,..~..- . · . ' '· '·
.'
/·y,
:;....'--<''.~-y~,~·~~-.
I= ~~. . .
NOTE: PROVIDE EROSION CONTROL
BLANKET FROM PROPERTY LINE OR
WETLAND LINE WHERE APPLICABLE
TO BACK OF CURB, BUILDING OR
TO TOP OF BASIN AS REQUIRED.
,J/
·~.
1. Erosion control measures will be utilized through out the construction phase of this
prgject to restri ct any turbid runoff from legving the construction site.
SWALE NOTE:
THE SYSTEM OF SWALES SHALL BE CONSTRUCTED BY THE. PERMITTEE PRIOR
TO RESALE OF INDIVIDUAL LOTS TO THIRD PARTIES.
2 . Control of sediment-laden runoff shall be provided with hoy bales and/or geotech
style fabrics. All contro l measures shall be properly located gnd constructed to
prevent sediment tronspgrt. The means fgr retaining the sediments will be maintained
by the contractor until permanent improvements are complete.
EROSION CONTROL NOTES:
ALL INLETS SHALL HAVE HAY BALES OR SILT FENCE AROUND THEIR PERIMITER.
J . The contractor is responsible f o r treating all onsite stormwater drainage as required
t o meet the criteria of 62-J Florido Administrative Code, F.A.C. prior to discharge.
SILT FENCE IS REQUIRED ALONG THE BANKS OF LAKE MERIAL AT THE 30'
SHORELINE SETBACK LINE, ALONG SWALES ANO ALONG WETLAND AREAS WHERE
CONSTRUCTION OR RUNOFF DUE TO CONSTRUCTION IS TAKING PLACE.
4 . All catch basins. inlets and accesses to underground stormwoter systems shall be
protected in accordance with the attached details.
SILT FENCE AND HAY BALES ARE REQUIRED IN ALL AREAS AS DIRECTED BY THE
ENGINEER.
5. The contractor is responsible for complying with the terms gnd conditions of any
stormwoter permits that may apply (Florido Deportment of Environmental Protection,
Florida Deportment of Transportation, Boy County, Water Management District, etc.) .
PROTECTED TREES NOTE:
NO PROTECTED TREES WILL BE IMPACTED UNLESS PERMITTED INDEPENDENTLY.
SLOPE STABILIZATION DETAIL
SLOPE STABILIZATION NOTES
FLAT TO 1:J - SEED AND MULCH, HYDRO-SEED OR SQQ.
1:3 TO 1:2 - SOD LAPPED AND PINNEO.
1:2 TO 1:1 - EROSION CONTROL BLANKET AND 500.
1:1 OR GREATER - RETAINING WALL OR ARMOR FORM .
NOTE:
AREAS NOT SODDED WILL BE STABILIZED WITH HYDROSEEOING
SEE SLOPE STABILIZATION DETAIL THIS SHEET
-
("')
N
Q)
Q)
.!:::
(/)
(/)
_J
ENYIRONMENTAL SEQUENCE
THE CONTRACTOR SHALL AT A MINIMUM IMPLEMENT THE CONTRACTOR'S REQU IREMENTS OUTLINED
BELOW ANO THOSE MEASURES SHOWN ON THE EROSION AND TURBIDITY CONTROL PLAN . IN ADDITION
THE CONTRACTOR SHALL UNDERTAKE ADDITIONAL MEASURES REQUIRED TO BE IN COMPLIANCE WITH
APPLICABLE PERMIT CONDITIONS ANO STATE WATER QUALITY STANDARDS.
SEQUENCE OF MAJOR ACTIVITIES:
THE ORDER OF ACTIVITIES WILL BE AS FOLLOWS:
1.
INSTALL STABILIZED CONSTRUCTION ENTRANCE.
INSTALL SILT FENCES AND HAY BALES, AS
REQU IRED.
9. INSTALL UTILITIES, STORM SEWER, CURBS·
AND GUTTER.
2~
3.
CONSTRUCT SEDIMENTATION BASIN.
1O. APPLY BASE TO PROJECT.
11. COMPLETE GRADING AND INSTALL
PERMANENT SEEDING/SOD AND PLANTING.
4. CLEAR AND GRUB FOR DIVERSION
SWALES/DIKES AND SEDIMENT BASIN AT
PERMANENT POND LOCATION.
12. COMPLETE FINAL PAVING.
5,
13. REMOVE ACCUMULATED SEDIMENT FROM
BASINS.
6.
CONTINUE CLEARING AND GRUBBING.
STOCKPILE TOP SOIL IF REQUIRED.
7. PERFORM PRELIMINARY GRADING ONSITE, AS
REQU IRED.
8. STABILIZE DENUDED AREA AND STOCKPILES
AS SOON AS PRACTICABLE.
14. WHEN ALL CONSTRUCTION ACTIVITY IS
COMPLITE AND THE SITE IS STABILIZED,
REMOVE ANY TEMPORARY DIVERSION
SWALES/DIKES AND RESEED/ SOD, AS
REQUIRED.
TIMING OF CONTROLS/MEASURES
AS INDICATED IN THE SEQUENCE OF MAJOR ACTIVITIES, THE SILT FENCES AND HAY BALES, STABILIZE D
CONSTRUCTION ENTRANCE AND SEDIMENT BASIN WILL BE CONSTRUCTED PRIOR TO CLEARING OR
GRADING OF ANY OTHER PORTIONS OF THE SITE. STABILIZATION MEASURES SHALL BE INITIATED AS
SOON AS PRACTICAL IN PORTIONS OF THE SITE WHERE CONSTRUCTION ACTI VITIES HAVE TEMPORARILY
OR PERMANENTLY CEASED. ONCE CONSTRUCTION ACTIVITY CEASES PERMANENTLY IN AN AREA, THAT
AREA WILL BE STABILIZED PERMANENTLY IN ACCORDANCE WITH THE PLANS. AFTER THE ENTIRE SITE
IS STABILIZED, THE ACCUMULATED SEDIMENT WILL BE REMOVED FROM THE SEDIMENT TRAPS AND THE
EARTH DIKE/SWALES WILL BE REGRADED/REMOVED AND STABILIZED IN ACCORDANC E WITH THE
EROSION AND TURBIDITY CONTROL PLAN.
10" MIN. - 2~ -3M
~-- C LEAN STONE
1--
w
0
GEOTEXTILE FABRIC
FOR DRAINAGE AND
FILTRATION
_6M CRUSHED
STONE BASE
_J
0
a::
1--
z
~~';~11~111~,"'·-·~111 111 111 111 111 111 111 111 111 111 11
111111111
1
111
111
111
111
111
111
111
111
-m '11=m-m=m-m-m-m-m-m-m
111
111
0
u
z
111
0
m-m-m~
(/)
GEOTEXTILE FABRIC
FOR SEPARATION
0
a::
w
z
~__ COMPACTED
SUBGRADE
CONSJBUCTION ENTRANCE NOTES:
0
1) GRADE SLOPE TO SITE.
2) PROVIDE CULVERT AS REQUIRED TO CARRY PRE-EXISTING
DITCH FLOW. (SEE EXISTING PLAN VIEW FOR LOCATION)
3) CONTRACTOR TO LOCATE TEMPORARY CONSTRUCTION FENCING,
JERSEY BARRIERS, OR BOTH ALONG THE SIDES OF THE
CONSTRUCTION EXIT TO PREVENT CONSTRUCTION TRAFFIC
FROM SHORT CIRCU ITING/BYPASSING THE EXIT.
4) ALL MATERIALS SPILLED, DROPPED OR TRACKED ONTO PUBLIC
ROADS (INCLUDING AGGREGATE STONE AND CONSTRUCTION
MUD) SHALL BE REMOVED DAILY.
(/)
>
0
en
:::>
(/)
z
0
1--
CONSTRUCTION ENTRANCE DETAIL
1--
z
NOT TO SCALE
a.
(/)
Q
~
i
~
REV
DATE
BY
SCALE ~
REVISIONS
~
0
JHS
DRAWN BY:
jdm
REVIEWED BY: J HS
~
~
DESIGN ED BY:
o----+-------1---+---------------------------------01-----------------------·
"fj
i:'
AS NOTE D
ISSU E DATE:
RELEASED FOR CONSTRUCTION
BY:
DATE :
ACAD FILE NAME :
ENGINEERING, INC.
MAY 2017
ENVIRONMENTAL ENGINEERS · CML ENGINEERS · LA.ND PLA.NNERS
3005 South Highway 77 Lynn Haven, Florida 32444
579 16 - B Detail Sheets .dwg
(850)763-5200
----~------~--~-------------------------------Of-----------------------·
NOT
.::PANHANDLE
@PANHANDLE ENGINEERING, INC. ALL RIGHTS RESERVED. NOPARTOF Tl-llSDOCUMENTMAY BE REPRODUCED ORUTILIZED IN#N FORM WITHOUT PRIOR WRITTEN Al.Jll10RIZATION OF PANHANDLE ENGINEERING, INC_
Fax (850)769-0730
pe@panhandleengineering.com
EROSION CONTROL DETAILS
ANDREWS PLANTATION SUBDIVISION
James H. Slonina. P.E. 39197
James M_ Southall, P_E 39637
Christopher B. Forehand, P.E. 58028
Stephen E_Price. P_E_71646
Jeffrey C. Petermann, P.E. 77540
SHEET NUMBER
23
PROJ ECT NUM BER
LYNN HAVEN, FLORIDA
QPR CERTIFI CATION #EB-7806
57916-B
sUJ
a::
0
z
en
'
(!)
~
O'>
I'L!)
FOR SCALE VERIFICATION AFTER DUP LICATION, T_HIS LINE, SHOU LD BE j" LONG
SITE DESCRIPTION
SUBDMSION EAST SIDE OF CR 389 (EAST AVE.) BETWEEN DUNOEE
LANE AND E 40th PLAZA
,
BAY COUNTY, FL. 324«
LAT JD"1J"29· ,.. LONG 65"J7'JJ"
SECTION TOWNSHIP RANGE ~ 15-JS-14W
PROJECT NAME AND LOCATION:
ND: HUMEl.E
DEVELOPER NAME ANO ADDRESS:
P.O. BOX ~4M
~ CITY. FL. J2412
DESCRIPTION:
SUBOMSION
IT IS THE CONTRACTORS RESPONSIBI LITY TO IMPLEMENT THE EROS ION AND TURBIDITY CONTROLS AS
SHOWN ON THE EROS ION AND TURBIDITY CONTRO L PLAN.
IT IS ALSO THE CONTRACTOR S
RESPONSIBILITY TO ENSURE 'fHESE CONTRO LS ARE PROPERLY INSTALLED, MAINTAINED AND
FUNCTIONING PROP ERLY TO PREV ENT TURBID OR POLLUTED WATER FROM LEAVIN G THE PROJECT SITE,
THE CONTRACTOR WILL ADJUST T[i,E EROS ION ANO !URBIDITY CONTROLS SHOWN ON THE EROS ION ANO
TURBIDITY CONTRO L PLAN ANO ADO ADD ITI ONA L CONTRO L MEASURES, AS REQUIRED, TO EN SUR E TH E
SITE Ml;:ETS ALL, FE DERAL, STATE AND LOCA L EROSION AND 1URBl.011Y CO~TRO L REQ.UIREMENTS . THE
FOLLOW ING BEST MANAGEMENT PRACTI CES WILL B E IMPLEMENTED BY THE CONTRACTOR AS REQUIRED
BY THE EROSION AND TU RB IDITY CONTRO L PLAN AND AS REQUIRED TO MEIT THE EROSION AND
TURBIDITY REQ UIREME('JTS IMPOSED ON THE PROJ ECT SITE SY THE REGULATORY AG EN CIES.
SOlL DISTURBING ACTIVITIES WILL INCLU DE:
CLEARING AND GRUBBING, EARTHWORK, PAVEM ENT AND GRADING, STORM WATER ANO UTILITIES.
RUNOFF CURVE NUMBERS:
' -1. ?RE- CONSTRUCTION
2.
J.
DURING CONSTRUCTION
POST- CONSTRUCTI ON
C= _
·
SEE ATIACHED 'EROSION AND TURBIDITY CONTRO L PLAN FOR LOCATION OF TEM PORARY
STAB ILI ZATI ON PRACTICES AND TURBI DllY BARRIERS.
SE E GRADING NOTES' FOR REQUIREM ENTS FOR TEM PORARY AND PERMAN ENT STA8 1LIZAT ION ,
1.) TOTAL AREA OF SITE = _ _ ± ACRES
2:) TOTAL AREA TO BE DISTURBED = APPROX.
NAME' OF RECEIVING WATERS:
THE FU LLO\l!ING GOOD HOUS EKEEPING PRACTICES WILL BE FOLLOWED ONSITE OUR ING THE CONSTR\JCTlON
PROJ ECT..,
ACRES
THESE. PRACTICES AR E USED TO REDUCE THE RISKS ASSOC IATED WITH HAZARDOUS MATERIALS.
STOCKPILING MATERIAL:
NO EXCAVAT ED MATERIAL SHOU LD B E STOCKPILED I~ SUCH A MANNER
AS TO DIRECT' RUNOFF DIRECTLY OFF THE PROJ ECT SITE INTO ANY ADJAC ENT WATER BODY OR STORM
WATER CO LLECTI ON FACI LI TY.
1.
IN STALL STABI LI ZED CON~TRUCTI ON ENTRAN CE.
CONCRETE TRUCKS WILL NOT BE ALLOW ED TO WASH OUT OR DISCHARGE SURPLUS CONCR ETE OR ·
ORUM WASH WATER ON THE: SITE.
!~STALL
AND GUTIE R.
1 1.
IN ADD ITI ON TO Tl--iE GOOD .HOUSEKEEPING AND MATERIAL MANAGEMENT PRACTI CES DISCUSS ED IN THE
PREVIOUS SECTI ONS OF >
THIS PLAN, THE FOLLOWING PRACTICES WILL BE FOLLOW ED FOR SPI LL
PREVENTION AND CLEANUP:
12. MAINTENANCE:"
MANUFACTURER'S RECOMM ENDED METHODS FOR SPILL CLEANUP WILL BE CLEARLY POSTED ON -SITE AND
SITE PERSONN EL WILL BE MADE AWARE OF THE PROC EDURES AND THE LOCATION OF THE INFORMATION
AND CLEAN UP SUPPLIES .
1J. P ERMAN ENT EROS ION CONTRO L: THE EROS ION CONTROL FACILITIES OF T HE PROJ ECT SHOU LD BE
DESIGNED TO MINIMIZE THE IMPACT ON THE OFFSITE FACILITIES.
MATERIALS AND EQUIPM ENT NECESSARY FOR SPILL CLEANUP WILL BE KEPT IN THE MATERIAL STORAGE
AREA ONSI TE . EQUIPM ENT AND MATERJALS WILL INCLUDE BUT NOT BE LIMITED TO BROOMS, DUST PANS,
MOPS, RAGS, GLOVES, GOGG LES, LIQU ID ABSORB ENT (i.e.:KITTY LITIER OR EOUAL), '$,.\ND. SAWDUST, AND
PLASTI C ANO METAL TRASH CONTAIN ERS SPECIFICAU Y FOR THIS PURPOS E.
TEM PORARY REGRASSING:
IF, AFTER 14 DAYS FROM SEEDING. Tl-iE' TEMPORARY GRASSED AREAS
HAVE NOT ATIAINED A MINIMUM ,75 P ERC ENl GOOD GRASS COVER, T.HE AREA WILL BE REWORK ED
AND ADD ITI ONA L. SEED APPLIED SU FFI CIE NT TO 'ESTAB LI SH THE DESIRED. VEGITATIVE COV ER,
14.
PERMANENT SEEDIN G:
AL L AREAS WHICH HAVE B EEN DISTURBED BY CONSTRUCTI ON WILL,. AS A
MINIMUM, BE SEE DED. THE SEEDING MIX MUST PROVIDE BOTj--1 LONG- TE RM VEGITAT ION A.ND RAPID
GROWTH SEASONAL VEGETATION . SLOP ES STEEP ER THAN 4 : 1 SHALL BE SEEDED AND MULCHED OR
SODD ED.
INSTALL SILT FEN CES AND HAY BALES, AS
REQU IRED.
3.
CONSTRUCT SEDIM ENTATI ON BASIN.
4. CLEAR AND GRUB FOR DIV ERS ION
SWALES/DIKES AND S.EOIMENT BASIN AT
PERMAN ENT POND LOCATION.
~~6T~~~L T~R~R~~~T Bl~~~~ r":~ ~~Ji~6EDw1~~DA p~~~OE~s·w~~LB~~~tPPROPRIATE
TEMPORARY DIVERSION DIKE: TEMPORARY DIVERS ION DIKES MAY BE' US ED TO DIV ERT RUNO FF
THROUG H A SEDIMENT- TRAPP ING FACILITY.
5.
CONTINUE CLEARING AND GRUBBING.
6.
STOCKPILE TOP SOIL IF REQU IRED.
14. WHEN ALL CONSTRUCTI ON ACTI VITY IS
COMP LETE AND THE. SI TE. IS STABILI ZED,
REMOVE ANY TEMPORARY DIVERS ION
SWALES/D IKES AND RESEED/ SOD, AS
REQUIRED.
7. PERFORM PR ELI MiNARY GRADING ONSITE, AS
REQ UIRED.
8.
AS INDICATED IN THE SEQUENCE OF MAJOR ACTIVITIES , ifH[ SILT FEN CES AND HA')' BALES, STABILI ZED
CONSTRUCTI ON ENTRANCE ANO SEDIMENT BASIN WILL BE CONSTRUCTED PRIOR 10 CLEARING OR
GRADING OF ANY OTHE R PORTI ONS OF' THE SITE. STABILI ZATION MEASURES SHALL B E INITIATE D AS
SOON AS PRACTI CAL IN PORTIONS OF THE SITE WHERE CONSTRUCTI ON ACTIVITIES HAVE TEMPORAR ILY
OR PERMAN ENTLY CEAS ED. ONC E CONSTRUCTION ACTIVITY CEAS ES P ERMA,N ENTLY IN AN AREA, THAT
AREA WILL BE STABI LIZED PERMANENTLY IN ACCORDANCE WITH THE PLANS. AFTER THE ENTI RE SITE
IS STABILIZED. THE ACCUMULATED SEDIM ENT WILL BE REMOVED FROM THE SEDIMENT TRAPS ANO THE
EARTH DIKE/SWALES WILL BE R EGRADED/R EMOV ED AND STABILI ZED IN ACCORDANC E WITH THE
EROS ION AND TURBIDITY CONTRO L PLAN .
ENDANGERED SPECIES AND CRITICAL HABITAT
1, ARE ifHERE EN DANG ERED SPECIES ON_ SITE?
IF YES TO EITHER QU ESTI ON. P LEASE EXPLAIN ~
STRUCTURE/
OUTFALL,
EROSION AND SEDIMENT CONTROL IN SP ECTION AND MAINTENANCE PRACTI CES
· ALL TU RBIDllY CONTRO L MEASURES WILL BE MAINTAINED IN GOOD WORKING ORD ER; IF A REPAIR IS
NECESSARY; IT WILL, 8 E INITIATED WITHIN 24 HOURS: OF REPORT.
ON OR BEFORE: _ _ _ __
PROJECT~
STORM WATER POLLUTION
INSPECTION
PREVENTION
PLAN
AND MAINTENANCE REPORT FORM
STORM WATER POU.UTION PREVENTION PLAN
INSPECTION AND MAINTENANCE REPORT FORM
SEDIMENT BASIN
DEPTH OF SEDIMENT IN
DEPTH OF SEDIMENT SIDE
BASIN
ANY EVIDENCE OF OVERTOPPING
OF THE EMBANKMENT ?
CONDITION OF OUTFALL
FROM SEDIMENT BASIN
· A MAINTENANCE INSPECTION REPORT WILL 8E MADE AFTER EACH IN SP ECTION. A COPY OF THE
REPORT FORM TO BE COMPLETED BY THE INSPECTOR IS ATIAC HED, THE REPORTS WILL 8 E KEPT ON
SITE DURING CONSTRUCTION AND AVAILAB LE UPON REQ UEST TO ;rHE OWN ER, ENGINEER OR ANY
FEDER,AL, STATE OR LOCAL AG EN CY APPROVING SEDIM ENT AND EROS ION PLANS, OR STORM WATER
MANAGEMENT PLANS. THE REPORTS SHALL BE MADE ANO RETAINED AS PART OF THE STORM WATER
PO LLUTI ON PREVENTION PLAN FOR AT LEAST TH REE YEARS Fl!CiM THE' DATE THAT THE SITE IS FINALLY
STABILI ZED AND THE NOTICE OF TERMINATION IS SUBM IT-TED THE REPORTS SHALL IDENTI FY ANY
INCIDENTS OF NON - COMPLIANC E~
MAINTENANCE REQUIRED FOR SEDIMENT BASIN::
· PERSONNEl SELECTED FOR INSPECTION AND MAINTENANCE RESPONSIB ILITIES WILL RECEIVE TRAINING
FROM THE SITE SUPERINTENDENT. THEY WILL BE TRAINED IN ALL l:HE. INSPECTION AND MAINTENANCE
PRACTI CES NECESSARY FOR KEEPI NG THE EROSION AND SEDIM ENT CONTRO LS VS ED ONS ITE' IN GOOD
WORKING ORDER.
Q)
TO BE PERFORMED
BY: _ _ _ _ _ _ _ _ _ _ _ _ __
ON
OR
·
..c
BEFORE: _ _ _ __
(/)
(/)
OlHER CONTROLS STABILIZED
UJ
CONSTRUCTION ENTRANCE
0
a_
DOES MUCH SEDIMENT GET
TRACKED ON TO ROAD ?
IS THE GRAVEL CLEAN OR
IS IT FILLED WITH
·SEDIMENT"?
z
DOES A[L TRAFFIC USE THE
IS THE CU LVERT BENEATH
STABILIZED ENTRANCE TO LEAVE. THE ENTRANCE WORKING? {IF
THE SrTE ?
APPLICABLE'
z
I CERTI FY UNDER PENALTY OF LAW THAT' T_HI S DOCUMENT' AND ALL ATIACHMENTS WERE PR EPAR ED UNDER MY
DIRECTI ON OR SUPERVISION IN ACCORDANC E WITH A SYSTEM DESIGNED TO ASSURE THAT QUALIFIED
PERSONN EL PROP ERLY GATHE RED AND EVALUATED THE INFORMATI ON SUBMITIED. BASED ON MY INQUiRY OF
THE PERSON OR PERSONS WHO MANAGE 'TH E: SYSTEM , OR TH OS E P ERSONS DIRECTLY RESPONSIBLE FOR
GATHERI NG THE INFORMATION, THE INFORMATI ON SUBMITIED IS, TO THE B EST OF fii'I' KNOW LEDG E /\ND B ELIEF,
TRU E. ACCURATE, ANO COMPL ETE. I AM AWARE THAT THERE ARE SIGNIFICANT PENALTIES FOR SUBMITIING
FALSE INFORMATI ON, IN CLUDING THE POSSIBILITY OF FINE AND IMPRISONM ENT FOR KNOWING VIOLATI ONS.
NON-STORM WATER DISCHARGES
IT IS EXPECTED THAT THE FOLLOWING NON-STORM WATER DISCHARG ES WILL OCCUR
FROM THE SITE DURING THE CONSTR.UCTION PERIOD:
N
Qi
ALL SAN ITARY WASTE WILL BE CO LLECTED FROM THAT PORTAB LE' UN ITS AS NEEDED TO PREV ENT
POSSIBLE SPILLAGE.
THE' WASTE 'WILL BE CO LLECTED AND DEPOSED OF IN ACCORDANCE 'WITH
STATE AND LOCAL WASTE D ISPOSAL REGULATIONS FOR SANITARY SEWER, OR SEPTI C SYSTEMS.
A ~TABILl.Z ED CONSTRUCJ ION ENTRANC E. WILL ,BE PR!JVl.QED 10 f1 ELp RED_UCE VEHI CLE TRAC!(IN9
OF SEDIMENTS. THE PAVED STREET ADJACENT TO THE SITE' ENTRANCE WI LL BE SW EPT AS
NEEDED TO REMOVE ANY EXCESS MUD, DIRT OR ROCK TRACKED FROM THE SITE. DUMP TRUCKS
HAULING MATERIAL FROM THE CONSTRUCTI ON SITE WILL B E COV ERED WITH THE: TARPAULIN ..
'
REASONS FOR CHANGES:
· THE SITE SUPERINTENDENT WILL SELECT UP TO TH REE INDIVIDUALS WHO WILL BE RESPONSIBLE FOR
INSPECTIONS, MAINTENANCE AND REPAIR ACTIVITIES, AND FILLING OUT THE IN SP ECTION AND
MAINTENANCE REPORT.
ALL HAZARDOUS WASTE MATERIALS WILL. BE: DISPOSED OF IN Tf'IE MANNER SPECIFIED BY LOCAL OR
STATE REGULATI ON OR BY THE MANUFACTURER, SITE P ERSONN EL WILL BE INSTRUCTED IN THESE
PRACTI CES AND THE SITE SUPERINTENDENT, THE INDIVIDUAL WHO MANAGES DAY -TO- DAY SITE
OP ERATI ONS, WILL BE RESPONSJBLE FOR SEEI NG THAT THESE PRACTICES ARE FOLLOWED.
MAINTENANCE REQUIRED FOR. STABILIZED CONSTRUCTION ENTRANCE;
WATER FROM WATER LINE FLUSHING.
'
THE M.ATERIALS OR SUBSTANCES LISTED BELOW ARE ~XPECTED TO BE
PRESENT ONSITE DURING CONSTRUCTION:
SIGNATURE:._ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __
Masonry Blocks
FOR NON-STORM \ll'ATER DISC HARG ES REFER TO lHE DEP GENERIC PERI.Ill FOR DISC HARGE
OF NON - CONTAMINATED PRODUCED GROUND WATER.
DATE: _ _ _ _ _ _ _ _ _ __
(http://www.dep.state.fl.us/legal/rules/shared/62-621 (2).doc)
Cleaning Solvents
D
Roofing Moteriols
Pojrits
D
Metal Studs
(/)
>
Cl
en
:J
z
0
UNCONTAMINfffED GROUNDWATER (FROM OEWATERING EXCAVAll ON),
~tL D7~cNH-,._~iE~M WATER DISCHARGES WILL SE DIRECTED TO THE SEOIMENT 8AS IN PRIOR
Wo od
0
(/)
· PAVEM ENT WASH WATERS (WHERE NO SPI LLS OR LEAKS OF TOXIC OR HAZARDOUS
'MATERIALS HAv'E ocCLIRRED).
INVENTORY FOR POLLUTION PREVENTION PLAN
Detergen.ts
CHANGES REQUIRED TO THE POLLUTION PREVENTION PLAN;'
* THE SEDIMENT BASIN S WILL BE INSPECTEO FOR THE DEPTH OF SEDIMENT, ANO BUILT UP SEDIMENT
WILL BE REMOVED WHEN IT REACHES 10 PERC ENT OF THE DESIGN CAPAC ITY OR AT THE EN D OF THE
J08, WHICHEVER CO MES FI RST-
HAZARDOUS WASTE
Petroleum Based Products
ON OR BEFORE;·._ _ _ __
· SI LT FENCE WILL BE INSPECTED FOR DEPT H OF SEDIMENT, TEARS. TO SEE IF THE FABRIC IS
SECUR ELY ATTACHED TO THE FENCE POSTS, ANO TO SEE THAT THE FENCE POSTS A.R E FIRMLY IN THE
GROUND.
ALL WASTE MATERIALS EXC EPT LAND CLEARING DEBRIS SHA LL BE CO L~ECTE D AND S TOR ED IN A
SECUR ELY LIDDED MITAL DUMPSTER. THE DUMPSTER WILL MEIT ALL LOCAL AND STATE SO LI D
WASTE MANAGEMENT REGULATI ONS,
THE DUMPSTER WILL B E EMPTIED AS NEEDED AND THE TRASH
WILL BE HAULED TO A ST.-i,TE APPROVED LANDFILL. ALL PERSONN EL wrLL BE INSTRUCTED
REGARDING THE, CORRECT PROC EDUR E FOR WASTE DISPOSAL. NOTI CES STATING THESE PRACTI CES
WILL BE POSTED AT THE CONSTRUCTION SITE BY THE CONSTRUCTI ON SUPERINTENDENT. THE
INDIVIDUAL WHO MANAGES THE' DAY -TO-DAY SITE OP ERATI ONS, Wil li_ BE RESPONSIB LE FOR SEEING
TH AT THESE' PROC EDURES ARE FOLLOW ED.
Asphalt
BY; _ _ _ _ _ _ _ _ _ _ _ _ __
· BlJILT UP SED IMENT WI LL BE REMOVED FROM SILT FENCE WH EN IT HAS REAC HED 9t4E-THIRD THE
HEIGHT OF THE FENCE.
· DIVERSION DIKES/ SWALES WILL BE. INSPECTED AND ANY BREAC HES PROMPTLY REPAIRED. ·
TEM PORARY ANO PERMAN ENT SEE DING ANO PLANTING WILL BE IN SP ECTED FOR BARE SPOTS,
WASHOUTS, ANO HEALTHY GROWTH.
D
D
'TO BE P ERFORMED
PAGE 2 OF 4·
PROJECT:
BASIN
WASTE DISPOSAL
WASTE MATERIALS
Fertilizers
DOES SILT NEED TO BE
REMOVED FROM AROUND
CONTROL
MAINTENANCE REQUIRED FOR CATCH BASIN/CURB INLETS/OUTFALLS TURBIDITY CONTROLS:
· AU CONTROL MEASURES WILL BE INSP ECTED BY THE SUPERINTENDENT. THE PERSON RESPONSIBLE
FOR THE DAY-TO-DAY SITE OP ERAT ION OF SOMEON E APPO INTED BY THE SUP ERINTENDENT , AT LEAST
ONC E A WEEK AND FOLLOW ING ANY STORM EVENT OF 0.25 INCHES OR GREATER.
THE 67 CUBIC YARDS OF STORAG E AREA PER ACRE DRAINED DO ES NOT APPLY TO FLOWS FROM
OFFSI TE AREAS AND FLOWS FRO~ ONS ITE AREAS THAT AR E EITHER UNDISTURBED OR HAVE
UNDER GON E FINAL STABILI ZATION WHERE .SUC H FLOWS ARE DIVERTE D AROUND BOTH 'r HE DISTURBED
AREA AND THE SEDIM ENT BASIN, ANY TEMPORARY SEDIMENT BASINS CONSTRUCTED MUST BE
BACKFILLE D AND COMPACTE D IN ACCORDANC E WITl-i THE SPECIFICATI ONS FOR STR UCTURAL FILL , ALL
SEDIM ENT CO LLECTED IN PERMAN ENT QR. TE).tPORARY S EDl ~ ENT TRAPS MUST B E REMOVED UPON
FINAL STABI LIZATIO N,
D
D
D
D
D
ARE TURBIDITY
CONTROLS IN NEED
OF REPLACING
STABILIZATION REQUIRED~
· NO MORE THAN l O ACR ES OF THE SITE WI LL BE DENUDED l\T ON E TIME WITHOUT WRITTEN
PERM ISSION FROM THE ENGINEER.
SEDIM ENT BASIN:
W!LL. B E CONSTRUCTED AT THE COMMON DRAINAGE LOCATI ONS. THE PROPOSED
STO_RM WATER PONDS (OR TEMPORARY PONDS) WILL B E CONSTRUCTE D FOR USE AS SEDIMENT BASIN S.
THE SE SEDIM ENT BASINS MUST PROVIDE .A t,.l lNIMUM OF 67 CUBIC YARDS OF STORAG E P ER ACRE
DRA_INED UNTIL FINAL STABILIZATION OF 'THE SITE. THE VOLUME. OF 'THE BASIN AT CLEAN OUT SHA LL
BE 22 CUBIC YARDS P ER ACRE.
Concrete
ANY · EVIDENCE OF
CLOGING/WASHOUT OR
BYPAsSING ?
THE FOLLOW IN G ARE INSP ECTI ON AND MAINTENANCE PRACTICES THAT WILL BE USED TO MAINTAIN
EROSION Ar_>IO SEDIMENT CONTROLS.
~-HE~~T+-~ ~~~Eg~g~b t:~L~C~~~~16~ ;~~ ~~bT~~To~R~~LL/JjE~oA~~E p~~~~1 v7~~N~~+-oiE~6 g:.s
D
D
D
D
D
ARE TURBIDITY
CONTROLS IN PLACE'
MAINTENANC E/INSPECTION PROCEDURES
1
OFFSITE VEHICLE TRACKING
BY: _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ ON OR BEFORE: _ _ _ __
PAG E 1 OF 4
SANITARY WASTE
2. AR E THERE CRITICAL HABITAT ON SITE ?
CONDITION
CATCH BASIN/CURB INLET/OUTFAU. TURB IDITY CQNTROLS
TO BE PERFORMED BY: _ _ _ _ _ _ _ _ _ _ _ _ _ __
OTHER CONTROLS
TIMING OF CONTROLS/MEASURES
STABILIZED WITH
TO BE PERFORMED
B.
GRAVEL SEDIM ENT TRAP - THIS PROTECTION IS APPLICABLE WHERE HEAV't' CONCENTRATED
l::LOWS AR E EXP ECTED, BUT NOT WH ERE PONDING AROUND THE STRUCTURE MIGHT CAUS E
EXC ESSIVE IN CONV ENl ~NC E OR DAMAGE TO ADJACENT STRUCTURES' AND UNPROTECT ED AREA.S.
STABILI Z E DEN UDED AREA AND STOCKPI LES
A'S SOON AS PRACTI CABLE.
STABILIZED
? (YES/NO)
THE SITE SUPERINTENDENT RESPONSIBLE FOR THE DAY - TO - DAY SITE OPERATIONS, WILL BE THE SPILL
PREVENTION ANO CLEAN UP COORD INATOR. HE/SHE WILL DESIGNATE AT LEAST ON E OTHER SITE
PERSONNEL WHO WILL REVEIW SPI LL PREVENTION ANO CLEAN UP lAAINING. THESE INDIVIDUALS WILL
EACH BECOME RESPONSIBLE FOR A PARTICULAR PHASE OF PREV ENTION AND CLEANUP, THE NAMES OF
RESPONSIBLE SPILL PERSONN EL WILL. BE POSTED 1N THE MATERIAL STORAG E AREA AND IF APPLICAB LE,
IN THE OFFI CE TRAILER ONS ITE_
A.
B LOCK AND GRAVEL SEDIMENT FILTER - THIS PROTECTI ON IS APP LI CAB LE WHERE HEAVY
l::LDWS AND/OR WHERE AN OV ERFLOW CAPACITY IS N"ECESSARY 10 PREVENT EXCESSIVE PONDING
AROUND THE STRUCTURE.
11 . COMP LETE GRADIN G AND INSTALL
13. REM OVE ACCUMULATED SEDIM ENT FROM
BASIN S.
DATE. OF NEXT
DISTURBANCE
PROTECTIVE
THE SPI LL PREVENTION PLAN WILL BE ADJUSTED TO IN CLUDE MEASURES TO PREVENT THI S 'll'P E OF
SPI LL FROM REOCCURR IN G A.ND HOW TO CLEAN UP THE SPILL IF THERE IS ANOTHER ON E. A
DESCRIPTION OF THE SPILL, WHAT CAUS ED IT, AND THE Cj_EANUP MEASURES WILL ALSO BE INCLUDED.
4.
12. COMP-LITE 'FINAL PAVING,
INCHES
ALL SPILLS Will BE CLEANE D UP ' IMMEDIATELY AFTE R DISCOVERY.
1.
10. APPLY BASE TO PROJ ECT.
PERMANENT SEEDING/SOD ANO PLANTIN G.
AMOUNT OF LAST RAINFALL
SPI LL OF TOXI C OR HAZARDOUS MA,TERIAL WILL BE REPORTED TO ·THE APPROPRIATE STATE OR LOCAL
GOVERN MENT AGENCY, REGARD LESS ·OF THE .SIZE OF THE SPI LL
SI LT FEN CES AND HAY BALES AR E TO B E INSTALLED IMMEDIATELY DOWNSTREAM OF TH E DISCHARG ING
STR UCTURE AS s·HOWN ON THE OUTLIT PROTECTI ON DETAIL.
2.
IS THERE EVIDENCE OF
WASHOUT OR OVERTOPPING
MAINTENANCE REQUIRED FOR EARTH DIKE/SWALE:
DAYS SINCE LAST RAINFALL: _ _ _ __
INSPECTION AREA
DAlE SINCE i.AST
DISTURBED
(DESCRIPTION OF LOCATION)
SPILL CONTROL PRACTICES
C.
DROP INLIT SEDIM ENT TRAP - THIS PROTECTI ON IS APP LI CABL E WHERE THE INLIT DRAINS
A RELATIVELY FLAT AREA (S <0.50%) AND WHERE SHEET OR OVERLAND FLOWS (0<0.50C FS)
AR E TYPICAL. THI S MITHOD SHALL NOT APPLY TO INLETS RECEIVING CONCENTRATED FLOWS
SUCH AS IN STREIT OR HI GHWAY MEDIANS.
UTILITIES, STORM SEWER, CURBS
IS DIKE/SWALE
STABILIZED ?
STABILIZATION MEASURES
THE FOLLOWING SEDIMENT TRAPS MA°Y B E CONSTRUCT ED EITHER INDE PENDENTLY OR IN CONJUNCTION
WITH A TEMPORARY DIVERS ION DIKE;
9.
SWALE
CONCRETE TRUCKS
10. TEMPORARY GRASSIN G: THE SEE DED OR SEEDED AND MULCHED AREA(S) SHALL BE ROLLED AND
WATERED OR HYDROMULCHED OR OTHER SUITABLE METHODS IF REQUIRED TO ASSUR E OPTIM UM
GROWING COND ITI ONS FOR THE ESTAB LI SiiMENT OF A GOOD GRASS COVER. TEM PORARY GRASSING
SHALL B E THE SAM E MIX AND AMOUNT REQU IRED FOR PERMAN ENT GRASSING IN THE CON}RACT
SP ECIF.ICATIONS.
FOL LOWS:
TO
FROM
DIKE OR
ALL CONTAIN ERS WILL 8E TIGHTLY SEALED AND STORED WHEN NOT REQUIR ED FOR USE, EJCC ESS PA INT
WILL NOT BE DISCHARGED TO THE STORM SEWER SYSTEM BUT WILL BE PROP ERLY DISPOSED OF
ACCORD IN G TO MANUFACTURER'S INSTRUCTIONS OR STATE AND LOCAL REGULATIONS.
TEMPORARY SEEDING AND MULCHING: SLOP ES STEEPER THAN 6:1 THAT FALL WITHIN THE
CATEGORY ESTAB LI SH ED IN PARAGRAPH 8 ABOVE SHALL ADDI TI ONALLY RECEIVE MULCHING OF
APPROX IMATELY 2 INCHES LOOS E MEASURE OF MULCH MATERIAL CUT INTO THE SOIL OF THE S EEDED
AR EA AD EQUATE TO PREV ENT MOVEMENT OF SEE D AND MULCH,
·SEQUENCE OF MJ&JOR ACTIVITIES:
AS~
INSPECTOR; _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ DATE: _ _ _ _ _ _ _ _ _ _ _ __
INSPECTOR'S QUALIFICATIONS:
9.
THE CO NTRACTOR SHALL AT A MINIMUM IMP LEMENT THE CONTRACTOR' S REQU IREMENTS OUT LI NED
IN ADD ITI ON
B ELOW AND TH OS E MEASURES SHOWN ON THE EROS ION AND TURBIDITY CONTRO L PLAN.
THE CO NTRACTOR S HAL ~. UNDERTAKE ADDITIONAL MEASURES REQU IRED TO BE IN COMP LIAN CE WI TH
APP LI CAB LE PERMIT COND ITI ONS AND STATE WATER QUALITY STANDARDS, DEP ENDING ON THE NATURE
OF MATERIALS AND METHODS OF CONSTRUCT ION THE CONTRACTOR MAY BE REQUIR ED TO ADO
FLOCCUJANTS TO THE RITENTION SYSTEM PRIOR TO p·~CING THE SYSTEM INTO OP ERATI ON .
THE ORDER OF ACTIVITIES WILL BE
MINIMUM AMOUNTS RECOMMENDED ff( THE
8E WoRK ED INTO ;rHE SOIL TO LIMIT EXPOSUR E TO
AREA, THE CONTENTS OF Afl.Y PARTIALLY USED
SEALAB LE PLASTI C BIN TO AVOIQ SPILLS.
PAINTS
2.
TEM PORARY SEDIMENT TRAP: A SEDIMENT TRAP SHALL BE INSTALLED IN A DRAINAGEWAY AT A
STORM DRAIN IN~ET OR AT OTHER PO INTS OF DISC HARG E FROM A DISTURBED AR EA.
GENERAL
~UCTURAL CONTROLS
EARTH DIKES/SWALES
FERTILIZERS USED WILL BE APPLI ED ON LY IN THE
MANUFACTURER, ONCE APP LIED, FERTILI ZER Will
STO RM WATER . ·STORAGE WILL BE IN A COVERED
BAGS OF FERT!LI ZER WILL BE TRANSFERRED TO A
STRUCTURAL PRACTICES
DAT ED: - - - - - - - - - - - - - - - - - - -
INSPECTION AND MAINTENANCE REPORT FORM
STORM WATER POLLUTION PREVENTION PLAN
INSPECTION ANO MAINTENANCE REPORT FORM
TO BE' COMPLETED EVERY T DAYS AND WITHIN ·24 HOURS
OF A RAINFALL EVENT OF 0.25 INCHES OR MORE
FERTILIZER S
ALL FEATURES OF THE PROJ ECT DESIGNED AND CONSTRUCT ED TO PREVENT
EROSION AND SEDIMENT SHALL B E MAINTAINED DURING THE LIFE ·OF 'THE' CONSTRUCTION SO AS TO
FUNCTION AS THI;)" WERE ORIGINALLY DESIGNED AND CONSTRUCTED.
SIGNED: - - - - - - - - - - - - - - - - - - - - - - - - - NAME {OP ERATOR AND/OR R ESPONS IB LE ATH ORITY)
PROJECT:
PROJECT:
ALL ONS rlE VEHI CLES WILL BE MONITORED F.OR LEAKS AND RECEIVE REGULAR PREVENTlVE
MAINTENANCE TO REOUC E THE CHAN_
CE OF LEAKAGE. PETRO LEUM PRODUCTS, WILL BE STOR ED
IN TIGHTLY S EALED CONTAIN ER S WHI CH AR E CLEARLY LABELED . ANY ASPHALT SUBSTANCES
USED ONS ITE WILL BE APPLIED ACCORDING TO THE MANUFACTURER'S RECOMM EN DATI ONS.
DUST CONTRO L: AREAS OPENED BY CONSTRUCTI ON OP ERATI ONS AND THAT AR E NOT ANTI CIPAT ED
TO B E RE-EXCAVATED OR DR ESS ED AND RECEIVE FINAL ;rREATMENT WITHIN 30 DAYS SHALL BE
STAB ILI ZED.
I CERTIFY UNDER PENALTY OF LAW THAT THI S DOCUM ENT AND ALL ATTACHM ENTS WERE PR EPAR ED
UNDER MY DIRECTI ON OR SUPERVISION IN ACCORDANCE WITH A SYSTEM DESIGNED TO ASSUR E THAT
QUALIFIED PERSONN EL PROPER LY GATHERED AND EVALUATED THE INFORMATlON SUBMITTED.
BASED
ON MY INQU IRY OF THE P ERSON OR PERSONS WHO MANAGE THE SYSTEM, OR THOSE PERSONS
DIRECTLY RES PONSIB LE FOR GATHERING THE INFORMATION, THE INFORMATI ON SUBMITTED IS, TO THE
BEST OF MY KNOW LEDG E AND BELIEF. TRUE, ACCURATE, AND COMPLETE. I AM AWARE THAT THERE
AR[ SIGNIFICANT P ENALTIES FOR SUBM ITIING FALSE INFORMATION, INCLUDING THE POSSIB ILITY OF FINE
AND IMPRISONMENT FOR KNOWING VIOLATIONS.
WWW.DEP,STATE.FLUS/WA~/STOfU1IWATER/NPD~
STORM WATER POLLUTION PREVENTION PLAN
8.
POLLUTION PREVENTION PLAN CERTIFICATION
THI S IS THE CONTRACTORS CERTIFICATION REQU IRED 8Y THE STATE OF FLORIDA NATIONAL PO_
LLUTI ON DjSCHARG°E ELIMINATI ON SYSTEM (~PDES), GENERIC PERM IT FOR
STORMWATER DISC HARGE FOR CONSTRUCTION SITES OVER 1 ACRES. THIS CERTIFICATION MUST BE COMPLETED WEEKLY AND AFTER EVERY RAINFALL EVENT OVER 0.25 INCHES.
jT IS SUGG ESTED THAT THI S SHEET BE' REMOVED FROM THE PLAN SET AND DUP LI CATED AS NEEDED BY THE CONTRACTOR. MORE INFORMATION MAY BE OBTAINEO AT
T.HEY CONTAIN IMPORTANT
PETROLEUM PRODUCTS
5.
7.
INLIT PROT ECTI ON:
INLETS ANO CATCH-BASINS WHICH DISCHARGE DIRECT LY OFF- SITE SHALL BE
PROTECTE D FORM SEDIMENT- LAD EN STORM RUNO FF UNTIL THE COMP LITI ON OF ALL CONSTRU CTI ON
OP ERATI ONS THAT MAY CON TRIBUTE SEDIMENT TO THE INLET.
FLORIDA ENVIRONMENTAL RESOURCE PERMIT
NOTE' TO CONTRACTO R;
PRODUCTS WILL BE KEPT IS ORIG INAL CONTAIN ERS UNLESS THEY AR E NOT ·RESEALAB LE.
PRODUCT SPECIFIC PRACTICES
THE FOLLOWING PRODUCT SP ECI FIC PRACTIC ES WILL 8 E FOLLOWED ONS ITE:
4.
LEVEL SPREADER: A LEVEL SPREADER MAY BE USED WHERE SEDIM ENT-FREE STORM RUNO FF IS
INTERCEPTED AND DIVERTED AWAY FROM THE GRADED AREAS ONTO UNDISTURBED STABILIZE D AREAS.
THIS PRACTICE APPLIES ON LY IN 'T_H_OS E SI TUAT!ONS WHERE THE SPREADER CAN BE CO NSTRUCTED ON
UNDISTURBED SOI L AND THE AREA B ELOW THE LEVEL LIP IS S TABI LI ZED.
THE WATER SHOU LD NOT
BE ALLOWED TO RECONC ENTRATE AFTER RELEASE'.
ONSITE IMPROVEMENTS
CONTRO L/MEASUR ES ,
IN ACCORDANCE WITH FEDERAL. STATE AN D LOCA L. LAWS RELATED TO
STORM WATER MANAGEMENT AND EROS ION AND TURBIDITY CONTRO LS,
THE F.O LLOW ING P ERM ITS HAVE BEEN OBTAINED.
MANUFACTLJ.RER'S ,RECOMM ENDATIONS FOR PROpE~ USE AND DISPOSAL WI LL ~E FOUOWEO .
· IF SURPLUS PRODUCT MUST BE DISPOSED OF. MANUFACTURER'S OR LOCAL AND STATE
RECOMM ENDED METHODS FOR PROP ER DISPOSAL WILL SE FOLLOW ED.
6.
EX POS ED AREA LIMITATION: THE SURFACE AREA OF OP EN, RAW ERODIBLE SOIL EX POS ED BY
CLEARIN G AND GRUBBING OP ERATI ONS OR EXCAVATION ANO FILLI NG OP ERATI ONS SHALL BE MINIMIZED.
C ERTIFICATION OF COMPLIANCE WITH FEDERAL, STATE AND LOCAL REGULATIONS
·
· ORIGINA L LABELS ANO MATERIAL SAFETY DATA WILL BE RE'fAINED;
PRODUCT INFORMATION,
STORM WATER MANAGEMENT
STORM WATER DRAINAGE WILL B E PROVID ED BY: ONS ITE CO LLECTI ON &: ATTENUATION
REFER TO "CONTRACTORS RESPONSIB ILITY'' fOR THE T!MING OF CONTRO L/MEASUR ES.
WHENEVER POSSIBLE, ALL OF (\ PRODUCf WILL BE USED llP BEFORE DISPOSING OF lHE CONTAIN ER.
HAZARDOUS PRODUCTS
CONTROLS
TIMING OF CONTROLS/~EASURES
·
·
BRUSH BARRIER WITH FILTER FABR'l'c:
BRUSH BA.RRI ER MAY BE USED BELdw DISTURBED AREAS
SUBJECT TO SHEIT AND RILL EROSION WHERE ENOUGH RESIDUE MATERIAL IS AVAILABLE ON SI TE .
SEE SITE, GRADING &: DRAINAGE AND UTILITY PLANS.
AN EFFORT WILL BE MADE TO STOR E ON LY ENOUG H PRODUCT REQUIRED TO DO THE JOS.
· THE SITE SllP ERINTEND,ENT WILL INSPECT DAILY TO ENSURE MATERIALS ONS ITE' RECEIVE PROP ER USE
AND DISPOSAL.
FILTER FABRIC BARRIER: FILTER FABRIC BARRIERS CAN BE USED BELOW DISTURBED AREAS
SUBJ ECT TO SHEET AND RI LL, EROSION WITH THE FOLLO,WING LIMITAJI ONS:
-3.
THI S P LAN UTILIZES B EST MANAGEMENT PRACTI CES TO CONTRO L EROSION AND TURBIDITY CAUS ED BY
S TORM WATER RUN - OFF. AN EROS ION .ANO TURBIDITY PLAN HAS B EEN PREPARED TO INSTRUCT THE
CONTRACTOR ON PLAC EMENT OF THESE CONTRO LS.
IT IS THE CONTRACTORS RESPONSIB ILllY TO
INSTALL AND MAINTAIN THE CONTROLS P ER PLAN AS WELL AS. EN SURING 'THAT PLAN IS PROVIDING
THE PROP ER PROTECTI ON AS REQUIRED BY FEDERAL, STATE AND LOCA L LAWS . REFER TO
·coNTRACTORS RESPONSIBILI TY" FOR A VERBAL DESCRIPTION OF THE CO NTR OLS 'THAT MAY BE
IMPLEMENTE D.
DATE
COMPANY ADDRESS AND PHONE NUMBER
· SUBSTANC ES WILL NOT BE MIXED WITH ONE ANOTHER UNLESS RECOMM EN DED BY THE
MANUFACTURER.
2.
REFER TO THE EROSION CO NTROL DITAILS FOR PROPER CONSTRUCTION OF THE FILTER FABRIC
BARRIER.
8"Y)
BEATTY BAYOU {NORTH
TITlE
· PRODUCTS WI LL 8 E KEPT IN THEIR OR IGINAL CONTAINERS WITH THE OR IGINAL MANUFACTURER'S
LABEL.
A. WHERE: T HE MAXIMUM SLOPE BEHI ND THE BARRIER IS 33 P ERC ENT,.
B. IN MINOR SWALES OF DITCH LINES Wl'1ERE THE MAXIMUM CONTRIBUTING DRAINAGE AREA IS
NO GREATER THAN 2 ACRES .
_±
NAME
· ALL MATERIALS STOR ED ONS ITE WILL SE STORED IN A NEAT, ORD ERLY· MANNER IN THEIR
APPROPRIAlE CONTAINERS ANO, IF POSSIBLE, UNDER A ROO F OR OTHER ENCLOSURE.
REFER TO EROSION CONTROL DETAILS FOR CO NSTRUCTING THE HAY BALE BARRIER. ALSO REFER 'TO
THE EROS ION CONTRO L PLAN FOR PROP ER LOCATION .
AREA:
I CERTI FY UNDER PENALTY OF' LAW 'THAT I UNDERSTAND AND SHALL COMPLY WITH THE TERM S ANO
CONDITI ONS OF THE STATE OF FLORIDA GENERAL PERMIT FOR STORMWATER DISCHARGE FROM LARGE
AND SMALL CONSTRUCTI ON ACTIVITIES AND THI S STORMWATER POLLUTI ON PREVENTION PLAN P.REPAREO
THEREUNDER.
GOOD HOUSEKEEPING
A. WHERE THE MAXIMUM SLOP E BEHIND THE BARRIER IS JJ P ERC ENT.
B . IN MINOR SWALES OR DITCH LINES WHERE THE MAXIMUM CONTRIBUTI NG DRAINAGE AREA IS
NO GREATE R THAN 'i ACR ES.
C. WHERE EFFECT IVENESS IS REQU IRED FOR LESS THAN .3 MONTHS.
D, EVERY EFFORT SHOU LD B E MADE TO LIMIT THE USE OF STRAW BALE BARRI ERS CONSTRUCTE D
IN LIVE STREAMS OR IN SWALES WH ERE THERE IS THE POSSIBILITY Of A WASHOUT. IF
NECESSARY, MEASURES SHA LL BE TAKEN TO PROPERLY ANC HOR BALES' TO ENSURE AGA INST
WASHOUT.
SITE MAPS;
·
SEE ATTACHED GRADING FO R PR E & POST DEVELOPMENT GRADES. AR EAS OF SOILS
DISTURBANCE, LOCATI ON OF SURFAC E WATERS. WETLANDS, PROTECTED AREAS. MAJOR STRUCTURAL
AND NONSTRUCTURAL CONTROLS AND STORMWATER DISC HARG E POINTS.
SITE
THE FOLLOWING AR E THE t.lATERIAL MANAGD~ENT PRACTICES l'HAT Will, BE USED TO REDUC E THE
RISK OF SPILLS OR OTHER ACCIDENTAL EXPOSURE' OF MATERIALS ANO SUBSTAN CES TO STORM
WATER RUNOFF.
1. HAY BALE BARRIER: HAY BA LE BARRIERS CAN BE USED BELOW DISTURBED AREAS SUBJECT TO
SH EIT AND RILL EROS ION WITH THE FOLLOW ING LIMITATIONS:
C- _
C= _
CONTRACTOR'S CERTIFICATION
_
M ATERIAL MANAGEMENT PRACTICES
EROSION AND SEDIMENT CONTROLS
STABILIZATION PRACTICES
SOILS:
SEE SOIL BORING REPORT FOR SOILS DA,TA
*
SPILL PREVENTION
CONTROLS
TO BE PERFORMED
BY: _ _ _ _ _ _ _ _ _ _ _ _ __
;::
z
ON OR BEFORE: _ _ _ __
::sa_
PAGE 3 OF 4
D
I-
PAG E 4 OF 4
(/)
.........~~~..........~~~~~~~~~~~~~--~~--~~~~~~~~~~~....~~~--~~~~~~~~~~--~~~~~...~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~.....~~~~~~~~~~~.-~~~~~~~--1s
W
REV
DATE
BY
R EVIS IONS
SCALE :·
D ES IGN ED
R~:::~
;:~
AS NOTE D
::.~::
BY:
ISSUE DATE :
J HS
MAY
··PANHANDLE
···
,
NPDES
.
ENGINEERING, INC.
ANDREWS PLANTATION SUBDIVISION
James H_ Slanina, P_E. '39197
"m~~&rn·'"·'E""'
Christopher B_ forehand , P.E. 58028
;!~~;~~p=1~~.:;;~- i.~64.,6, 540
SHEET NUMB ER
24
PRO~ ECT NUMBE R
2017
----~------~--~-------------------------------If-----------------------·
ENVIRONMENTALENGINEERS ·
CMLENGINEERS ·
LANDPIJl.NNERS
3005 South Highway 77 Lynn J-laven.. Florida 32444
LYNN HAVEN FLORIDA
57916-8
NOT
RE LEAS ED FOR CONST RUCTI ON
BY:
DATE:
ACAO f'"ILE NAM E : 57916'- B Deta i l Sheets.dwg
(850)763-5200 Fax(850)769-0730 pe@panhandleengineering.com
J
C ERTIFI CAT ION
EB -7806
.....................................................................................................................................
____________________________________
...____________________________________________________________________________________________
...DPR
________
_..# __________________
..,_____________________ .
~ i!""'__
0
© PANHA_NDLE ENGINEERING, INC. AU.RIGHTS RESERVEO.
NO PART OF THIS DOCUMENJ _
MAY BE REPRODUCED OR lJTILIZED IN M-N FORM WITHOUT PRIOR WRITTEN AUll10RIZAnoN OF PANHANDLE ENGINEERING, INC.
Cl'.
O
z
:
f.b
;;:;
VJ
f'-
~