You can copy from here when filling out the rest of the page.
PERSONNEL, BARGE AND EQUIPMENT DOCK INSTALLATIONS FOURCHON TERMINAL, LAFOURCHE PARISH
NAME OF APPLICANT: CHEVRON PIPE LINE COMPANY, c/o T. Baker Smith, Attn: Jeffrey Hargis, Post Office Box 2266, Houma, Louisiana 70361
LOCATION OF WORK: California Canal and Pass Fourchon at the Fourchon Terminal, located in Section 24, Township 23 South, Range 22 East, Port Fourchon, Louisiana, (29.106077, -90.193469), in Lafourche Parish, as shown on the enclosed drawings, within Hydrologic Unit Code 08090301 East Central Louisiana Coastal.
CHARACTER OF WORK: The applicant has requested Department of the Army authorization to install and maintain a 6.5-ft wide by 70-ft long steel personnel boat dock and walkway in the California Canal (29.106077, -90.193469), and to install and maintain a 3.5-ft wide by 39-ft long steel barge dock walkway, and a 14-ft wide by 40-ft long steel loading ramp with timber and steel piles in Pass Fourchon (29.104880, -90.190625), all to ensure continuity of safe operations at Fourchon Terminal since a bridge along Louisiana Highway 3090 that serves as the only means of access to the site, will be removed by the Lafourche Parish Government. Three (3) 8-ft by 20-ft articulated concrete mats will be placed under the steel loading ramp for erosion control. A proposed winch mounted on a 30” steel piling will be installed on the existing gravel parking lot. All construction activities will be conducted from the water on barges. No dredging or wheel washing is required. The site is an industrial facility and there are no jurisdictional wetlands that will be impacted by this project.
JOINT PUBLIC NOTICE
October 16, 2017
United States Army
Corps of Engineers
New Orleans District
Attn: Regulatory Branch
7400 Leake Avenue
New Orleans, Louisiana 70118
State of Louisiana
Department of Environmental Quality
Attn: Office of Environmental Services
Post Office Box 4313
Baton Rouge, Louisiana 70821-4313
Project Manager: Dirreen Arnold
(504) 862-2301 / fax: (504) 862-2574
dirreen.s.arnold@usace.army.mil
Permit Application Number:
MVN-2017-01238-CA
Project Manager:
Elizabeth Hill
(225) 219-3225 / fax: (225) 219-3156
WQC Application Number:
WQC-171009-01
Interested parties are hereby notified that a permit application has been received by the
New Orleans District of the US Army Corps of Engineers pursuant to: [X] Section 10 of the
Rivers and Harbors Act of March 3, 1899 (30 Stat. 1151; 33 USC 403); and/or [X] Section 404
of the Clean Water Act (86 Stat. 816; 33 USC 1344).
Application has also been made to the Louisiana Department of Environmental Quality,
Office of Environmental Services, for a Water Quality Certification (WQC) in accordance with
statutory authority contained in LRS 30:2074 A(3) and provisions of Section 401 of the Clean
Water Act.
PERSONNEL, BARGE AND EQUIPMENT DOCK INSTALLATIONS
FOURCHON TERMINAL, LAFOURCHE PARISH
NAME OF APPLICANT: CHEVRON PIPE LINE COMPANY, c/o T. Baker Smith, Attn: Jeffrey
Hargis, Post Office Box 2266, Houma, Louisiana 70361
LOCATION OF WORK: California Canal and Pass Fourchon at the Fourchon Terminal,
located in Section 24, Township 23 South, Range 22 East, Port Fourchon, Louisiana,
(29.106077, -90.193469), in Lafourche Parish, as shown on the enclosed drawings, within
Hydrologic Unit Code 08090301 East Central Louisiana Coastal.
CHARACTER OF WORK: The applicant has requested Department of the Army authorization
to install and maintain a 6.5-ft wide by 70-ft long steel personnel boat dock and walkway in the
California Canal (29.106077, -90.193469), and to install and maintain a 3.5-ft wide by 39-ft long
steel barge dock walkway, and a 14-ft wide by 40-ft long steel loading ramp with timber and
steel piles in Pass Fourchon (29.104880, -90.190625), all to ensure continuity of safe
operations at Fourchon Terminal since a bridge along Louisiana Highway 3090 that serves as
the only means of access to the site, will be removed by the Lafourche Parish Government.
Three (3) 8-ft by 20-ft articulated concrete mats will be placed under the steel loading ramp for
erosion control. A proposed winch mounted on a 30" steel piling will be installed on the existing
gravel parking lot. All construction activities will be conducted from the water on barges. No
dredging or wheel washing is required. The site is an industrial facility and there are no
jurisdictional wetlands that will be impacted by this project.
-2-
The comment period for the Department of the Army Permit and the Louisiana
Department of Environmental Quality WQC will close 20 days from the date of this joint public
notice. Written comments, including suggestions for modifications or objections to the
proposed work, stating reasons thereof, are being solicited from anyone having interest in this
permit and/or this WQC request and must be submitted so as to be received before or by the
last day of the comment period. Letters concerning the Corps of Engineers permit application
must reference the applicant's name and the Permit Application Number, and be forwarded to
the Corps of Engineers at the address above, ATTENTION: REGULATORY BRANCH. Similar
letters concerning the Water Quality Certification must reference the applicant's name and the
WQC application number and be mailed to the Louisiana Department of Environmental Quality
at the address above. Individuals or parties may request an extension of time in which to
comment on the proposed work by writing, faxing, or e-mailing the Corps of Engineers Project
Manager listed above. Any request must be specific and substantively supportive of the
requested extension, and received by this office prior to the end of the initial comment period.
The Section Chief will review the request and the requestor will be promptly notified of the
decision to grant or deny the request. If granted, the time extension will be continuous to the
initial comment period and, inclusive of the initial comment period, will not exceed a total of 30
calendar days.
The application for this proposed project is on file with the Louisiana Department of
Environmental Quality and may be examined during weekdays between 8:00 a.m. and 4:30
p.m. Copies may be obtained upon payment of costs of reproduction.
Corps of Engineers Permit Criteria
The decision whether to issue a permit will be based on an evaluation of the probable
impacts, including cumulative impacts of the proposed activity on the public interest. That
decision will reflect the national concern for both protection and utilization of important
resources. The benefit which reasonably may be expected to accrue from the proposal must be
balanced against its reasonably foreseeable detriments. All factors which may be relevant to
the proposal will be considered including the cumulative effects thereof; among those are
conservation, economics, aesthetics, general environmental concerns, wetlands, historic
properties, fish and wildlife values, flood hazards, floodplain values, land use, navigation,
shoreline erosion and accretion, recreation, water supply and conservation, water quality,
energy needs, safety, food and fiber production, mineral needs, considerations of property
ownership and, in general, the needs and welfare of the people.
-3-
The U.S. Army Corps of Engineers is soliciting comments from the public, federal, state,
and local agencies and officials, Indian Tribes, and other interested parties in order to consider
and evaluate the impacts of this proposed activity. Any comments received will be considered
by the U.S. Army Corps of Engineers to determine whether to make, modify, condition, or deny
a permit for this proposal. To make this decision, comments are used to assess impacts on
endangered species, historic properties, water quality, general environmental effects, and other
public interest factors listed above. Comments are used in the preparation of an Environmental
Assessment and/or an Environmental Impact Statement pursuant to the National Environmental
Policy Act. Comments are also used to determine the need for a public hearing and to
determine the overall public interest of the proposed activity.
The New Orleans District is unaware of properties listed on the National Register of
Historic Places near the proposed work. The possibility exists that the proposed work may
damage or destroy presently unknown archeological, scientific, pre-historical, historical sites, or
data. Issuance of this public notice solicits input from the State Archeologist and State Historic
Preservation Officer regarding potential impacts to cultural resources.
The New Orleans District has determined that the proposed project is located within
waters known to be occupied by the endangered West Indian Manatee (Trichechus manatus)
and determined with the inclusion of the Standard Manatee Conditions for In-Water Activities
the proposed activity is not likely to adversely affect the species based on the Standard Local
Operating Procedure for Endangered Species in Louisiana (SLOPES), dated October 22, 2014,
between the U.S. Army Corps of Engineers, New Orleans and U.S. Fish and Wildlife Service,
Ecological Services Office.
This notice initiates the Essential Fish Habitat (EFH) consultation requirements of the
Magnuson-Stevens Fishery Conservation and Management Act. The applicant's proposal may
result in the destruction or alteration of 0.0 acres of EFH utilized by various life stages of red
drum and penaeid shrimp. Our initial determination is that the proposed action would not have
a substantial adverse impact on EFH or federally managed fisheries in the Gulf of Mexico. Our
final determination relative to project impacts and the need for mitigation measures is subject to
review by and coordination with the National Marine Fisheries Service.
If the proposed work involves deposits of dredged or fill material into navigable waters,
the evaluation of the probable impacts will include the application of guidelines established by
the Administrator of the Environmental Protection Agency. Also, a certification that the
proposed activity will not violate applicable water quality standards will be required from the
Department of Environmental Quality, before a permit is issued.
Any person may request, in writing, within the comment period specified in this notice,
that a public hearing be held to consider this application. Requests for public hearings shall
state, with particularity, the reasons for holding a public hearing. You are requested to
communicate the information contained in this notice to any other parties whom you deem likely
to have interest in the matter.
-4-
The applicant has certified that the proposed activity described in the application
complies with and will be conducted in a manner that is consistent with the Louisiana Coastal
Resources Program. The Department of the Army permit will not be issued unless the
applicant received approval or a waiver of the Coastal Use Permit by the Department of Natural
Resources.
JOHN M. HERMAN
Chief, Central Evaluation Section
Regulatory Branch
Enclosure
LAFOURCH PARISH, LOUISIANA
20 MILES SOUTH OF GOLDEN MEADOW
THESE DRAWING ARE TO BE USED FOR THE
ACQUISITION OF REGULATORY PERMITS ONLY
DRAWN BY:
DATE:
SJK
APPROVED BY:
09/13/17
JOB NO:
DRAWING NAME:
2017.0812
170812P01-02.DWG
1
SHEET NO:
JMH
OF
12
PROJECTION: LA SOUTH
GEO. DATUM: NAD83 | VERT. DATUM: NAVD88
GRID UNITS: US SURVEY FEET
SCALE: 1" = 4 Miles
4 Miles
2 Miles
0
PROJECT VICINITY
CHEVRON PIPE LINE COMPANY
PROPOSED INSTALLATION OF
A PERSONNEL DOCK & EQUIPMENT DOCK
FOURCHON TERMINAL
SECTION 24, T23S-R22E
LAFOURCHE PARISH, LOUISIANA
REV. NO:
4 Miles
00
REV. DATE:
REVISION DESCRIPTION:
--
--/--/--
REV. BY:
---
LAFOURCH PARISH, LOUISIANA
SECTION 24, T23S-R22E
THESE DRAWING ARE TO BE USED FOR THE
ACQUISITION OF REGULATORY PERMITS ONLY
DRAWN BY:
DATE:
SJK
APPROVED BY:
09/13/17
JOB NO:
DRAWING NAME:
JMH
2017.0812
170812P01-02.DWG
2
SHEET NO:
OF
12
PROJECTION: LA SOUTH
GEO. DATUM: NAD83 | VERT. DATUM: NAVD88
GRID UNITS: US SURVEY FEET
SCALE: 1" = 2000'
2000'
1000'
0'
PROJECT VICINITY
CHEVRON PIPE LINE COMPANY
PROPOSED INSTALLATION OF
A PERSONNEL DOCK & EQUIPMENT DOCK
FOURCHON TERMINAL
SECTION 24, T23S-R22E
LAFOURCHE PARISH, LOUISIANA
REV. NO:
2000'
00
REV. DATE:
REVISION DESCRIPTION:
--
--/--/--
REV. BY:
---
+10'
8.2'
F
SS
PA
OU
HW
Y
H
RC
30
90
ON
8.3'
MARSH
8.1'
MARSH
9.2'
6.9'
CALIFORNIA CANAL
10.7'
10.9'
10.1'
7.3'
5.2'
SITE OF BOAT DOCK (PERSONNEL)
8.1'
8.8'
CHEVRON
FOURCHON TERMINAL
7.3'
SITE OF EQUIPMENT DOCK/RAMP
THESE DRAWING ARE TO BE USED FOR THE
ACQUISITION OF REGULATORY PERMITS ONLY
DRAWN BY:
DATE:
SJK
APPROVED BY:
09/13/17
JOB NO:
DRAWING NAME:
2017.0812
170812P01-02.DWG
3
SHEET NO:
JMH
OF
12
PROJECTION: LA SOUTH
GEO. DATUM: NAD83 | VERT. DATUM: NAVD88
GRID UNITS: US SURVEY FEET
SCALE: 1" = 300'
300'
150'
0'
ACCESS
CHEVRON PIPE LINE COMPANY
PROPOSED INSTALLATION OF
A PERSONNEL DOCK & EQUIPMENT DOCK
FOURCHON TERMINAL
SECTION 24, T23S-R22E
LAFOURCHE PARISH, LOUISIANA
REV. NO:
300'
00
REV. DATE:
REVISION DESCRIPTION:
--
--/--/--
REV. BY:
---
APPROXIMATELY 195±
FROM END OF DOCK
TO OPPOSITE BANKLINE
CALIFORNIA CANAL
270'
TEMPORARY WORKSPACE
END PROPOSED DOCK
I
AL
X = 3,644,864'
Y = 222,298'
LAT = 29° 6' 22.59"
LONG = 90° 11' 36.49"
M
GN
T
EN
POSSIBLE VESSEL LOCATIONS
FOR CONSTRUCTION
NAD 83
NAD 83
M
AY
RY
VA
180'
225'
CITY OF
NEW ORLEANS
SWD # 1
120' x 38'
CRANE BARGE
PROPOSED BOAT
DOCK WALKWAY
WELL W
50' x 18'
TUG
ALKWA
Y
130' x 30'
DECK BARGE
EXISTING BULKHEAD
EXIST. BUILDING
BEGIN PROPOSED DOCK
X = 3,644,864'
Y = 222,227'
LAT = 29° 6' 21.88"
LONG = 90° 11' 36.49"
NAD 83
NAD 83
SEE PAGE 6
PERSONNEL DOCK
CROSS SECTION
EXISTING CHEVRON FOURCHON TERMINAL
THESE DRAWING ARE TO BE USED FOR THE
ACQUISITION OF REGULATORY PERMITS ONLY
DRAWN BY:
DATE:
SJK
APPROVED BY:
09/13/17
JOB NO:
DRAWING NAME:
2017.0812
170812P01-02.DWG
4
SHEET NO:
JMH
OF
12
PROJECTION: LA SOUTH
GEO. DATUM: NAD83 | VERT. DATUM: NAVD88
GRID UNITS: US SURVEY FEET
SCALE: 1" = 50'
50'
25'
0'
BOAT DOCK (PERSONNEL) WORKSPACE
CHEVRON PIPE LINE COMPANY
PROPOSED INSTALLATION OF
A PERSONNEL DOCK & EQUIPMENT DOCK
FOURCHON TERMINAL
SECTION 24, T23S-R22E
LAFOURCHE PARISH, LOUISIANA
REV. NO:
50'
00
REV. DATE:
REVISION DESCRIPTION:
--
--/--/--
REV. BY:
---
IMPACTS:
12" TIMBER PILES:
6 TO BE INSTALLED IN WATER:
QTY. 6
6 sqft.
0 CUBIC YARDS OF MATERIAL REMOVED
PASS FOURCHON
NG
TI
IS
EX
5±
18 K
LY OC LINE
E
D
AT F NK
IM D O BA
OX EN TE
R
P M SI
AP RO PO
F OP
TO
CK
RO
END PROPOSED DOCK
100'
NK
BA
X = 3,645,808'
Y = 221,825'
LAT = 29° 6' 17.81"
LONG = 90° 11' 25.90"
NAD 83
NAD 83
PROPOSED BARGE
DOCK & WALKWAY
'
18
'x G
50 TU
PROPOSED
PILE CLUSTER
0' E
x3 G
0' AR
13 K B
C
DE
8' E
x 3 RG
0' BA
12 E
N
A
CR
SEE PAGE 6
EQUIPMENT DOCK
CROSS SECTION
225'
POSSIBLE VESSEL
LOCATION
BEGIN PROPOSED DOCK
X = 3,645,777'
Y = 221,801'
LAT = 29° 6' 17.57"
LONG = 90° 11' 26.25"
NAD 83
E
AC
NAD 83
P
KS
PROPOSED PILE CLUSTER
OR
RY
EXISTING PARKING
W
RA
M
TE
PO
110'
THESE DRAWING ARE TO BE USED FOR THE
ACQUISITION OF REGULATORY PERMITS ONLY
DRAWN BY:
DATE:
SJK
APPROVED BY:
09/13/17
JOB NO:
DRAWING NAME:
2017.0812
170812P01-02.DWG
5
SHEET NO:
JMH
OF
12
PROJECTION: LA SOUTH
GEO. DATUM: NAD83 | VERT. DATUM: NAVD88
GRID UNITS: US SURVEY FEET
SCALE: 1" = 50'
50'
25'
0'
EQUIPMENT DOCK/RAMP WORKSPACE
CHEVRON PIPE LINE COMPANY
PROPOSED INSTALLATION OF
A PERSONNEL DOCK & EQUIPMENT DOCK
FOURCHON TERMINAL
SECTION 24, T23S-R22E
LAFOURCHE PARISH, LOUISIANA
REV. NO:
50'
00
REV. DATE:
REVISION DESCRIPTION:
--
--/--/--
REV. BY:
---
CROSS SECTION "PERSONNEL DOCK "
LOOKING EAST
20'
15'
20'
12.00'
15'
M.H.W. = 1.5'
10'
M.L.W. = 0.0'
5'
5'
NATURAL GROUND
0'
NAVD88
10'
NAVD88
PROPOSED CRANE
BARGE PLACEMENT
38' WIDE
PROPOSED DECK
BARGE PLACEMENT
30' WIDE
0'
5' DRAFT
5' DRAFT
-5'
-5'
NATURAL BOTTOM
-10'
-10'
EXISTING SHEET
PILE BULKHEAD
-15'
-15'
CROSS SECTION "EQUIPMENT DOCK"
LOOKING NORTHWEST
20'
20'
10'
15'
PROPOSED DECK
BARGE PLACEMENT
30' WIDE
15'
NAVD88
10'
M.H.W. = 1.5'
M.L.W. = 0.0'
5'
5'
NATURAL GROUND
0'
0'
5' DRAFT
5' DRAFT
-5'
P:\Y-2017\2017.0812\DWG\PERMIT\170812P04-11.DWG
10'
-5'
NATURAL BOTTOM
-10'
-15'
-15'
THESE DRAWING ARE TO BE USED FOR THE
ACQUISITION OF REGULATORY PERMITS ONLY
SCALE: 1" = 20'
DRAWN BY:
DATE:
20'
10'
0'
20'
SJK
09/13/17
DRAWING NAME:
SHEET NO:
APPROVED BY:
JOB NO:
00
REV. DATE:
--/--/--
REV. BY:
---
JMH
2017.0812
170812P01-02.DWG
6
OF
12
PROJECTION: LA SOUTH
GEO. DATUM: NAD83 | VERT. DATUM: NAVD88
GRID UNITS: US SURVEY FEET
REV. NO:
-10'
REVISION DESCRIPTION:
--
EQUIPMENT ACCESS PROFILE
CHEVRON PIPE LINE COMPANY
PROPOSED INSTALLATION OF
A PERSONNEL DOCK & EQUIPMENT DOCK
FOURCHON TERMINAL
SECTION 24, T23S-R22E
LAFOURCHE PARISH, LOUISIANA
NAVD88
PROPOSED CRANE
BARGE PLACEMENT
38' WIDE
CALIFORNIA CANAL
20'±
PROPOSED TIMBER
BRACING
20'±
17'±
12'±
PROPOSED
STEEL WALKWAY & CABLE
TRAY SUPPORTS
PROPOSED
STEEL WALKWAY
TIE INTO EXISTING
STAIRCASE
PROPOSED
STAIRS
10'± 6.5'±
10'±
10'±
10'±
10'±
PROPOSED TIMBER
BRACING
PROPOSED 12" DIA.
PILE LOCATIONS
PROPOSED 12" DIA.
PILE LOCATIONS
PROPOSED 12" DIA.
PILE LOCATIONS
P:\Y-2017\2017.0812\DWG\PERMIT\170812P04-11.DWG
42'±
GRAVEL
IMPACTS:
EXISTING
BULKHEAD
THESE DRAWING ARE TO BE USED FOR THE
ACQUISITION OF REGULATORY PERMITS ONLY
SCALE: 1" = 10'
DRAWN BY:
DATE:
10'
5'
0'
10'
SJK
09/13/17
DRAWING NAME:
SHEET NO:
APPROVED BY:
JOB NO:
2017.0812
170812P01-02.DWG
7
OF
12
PROJECTION: LA SOUTH
GEO. DATUM: NAD83 | VERT. DATUM: NAVD88
GRID UNITS: US SURVEY FEET
REV. NO:
00
REV. DATE:
--/--/--
REV. BY:
---
JMH
REVISION DESCRIPTION:
--
12" TIMBER PILES: QTY. 12
8 TO BE INSTALLED IN WATER:
8 sqft.
4 TO BE INSTALLED ON LAND:
4 sqft.
0 CUBIC YARDS OF MATERIAL REMOVED
BOAT DOCK (PERSONNEL) DETAIL
CHEVRON PIPE LINE COMPANY
PROPOSED INSTALLATION OF
A PERSONNEL DOCK & EQUIPMENT DOCK
FOURCHON TERMINAL
SECTION 24, T23S-R22E
LAFOURCHE PARISH, LOUISIANA
PROPOSED DOCK INSTALLATION
LOOKING EAST
20'
20'
40'± PROPOSED BARGE DOCK
TIE INTO EXISTING
PLATFORM
30'± PROPOSED WALKWAY
15'
15'
PROPOSED STEEL DECK
AND HANDRAIL
PROPOSED TIMBER
BRACING
10'
PROPOSED STAIRS
10'
5'
5'
NATURAL GROUND
M.H.W. = 1.5'
M.L.W. = 0.0'
0'
0'
NATURAL BOTTOM
-5'
-5'
EXISTING SHEET
PILE BULKHEAD
-10'
-10'
P:\Y-2017\2017.0812\DWG\PERMIT\170812P04-11.DWG
-15'
-15'
PROPOSED 12" DIA.
PILE LOCATIONS
PROPOSED 12" DIA.
PILE LOCATIONS
PROPOSED 12" DIA.
PILE LOCATIONS
THESE DRAWING ARE TO BE USED FOR THE
ACQUISITION OF REGULATORY PERMITS ONLY
SCALE: 1" = 10'
DRAWN BY:
DATE:
10'
5'
0'
10'
SJK
09/13/17
DRAWING NAME:
SHEET NO:
APPROVED BY:
JOB NO:
2017.0812
170812P01-02.DWG
8
OF
12
PROJECTION: LA SOUTH
GEO. DATUM: NAD83 | VERT. DATUM: NAVD88
GRID UNITS: US SURVEY FEET
REV. NO:
00
REV. DATE:
--/--/--
REV. BY:
---
JMH
REVISION DESCRIPTION:
--
BOAT DOCK (PERSONNEL) PROFILE
CHEVRON PIPE LINE COMPANY
PROPOSED INSTALLATION OF
A PERSONNEL DOCK & EQUIPMENT DOCK
FOURCHON TERMINAL
SECTION 24, T23S-R22E
LAFOURCHE PARISH, LOUISIANA
39'± PROPOSED
BARGE DOCK
PROPOSED 12" DIA.
WOODEN PILES
PROPOSED 12" DIA.
WOODEN PILES
PROPOSED
STEEL WALKWAY
PROPOSED TIMBER
BRACING
PROPOSED
WOODEN PILE CLUSTER
GRAVEL
PROPOSED 12" DIA.
WOODEN PILES
3.5'±
10'±
10'±
10'±
7'±
PROPOSED
16" STEEL PILE
PROPOSED
12" STEEL PILE
PASS FOURCHON
20'±
14'±
PROPOSED WINCH
MOUNTED ON SINGLE
30" STEEL PILING
PROPOSED
WOODEN PILE CLUSTER
PROPOSED
12" STEEL PILE
24'±
PROPOSED
16" STEEL PILE
IMPACTS:
12" TIMBER PILES: QTY. 16
16 TO BE INSTALLED IN WATER:
16 sqft.
16" STEEL PILES:
QTY. 2
2 TO BE INSTALLED IN WATER:
3 sqft.
24" STEEL PILES:
QTY. 2
2 TO BE INSTALLED IN WATER:
6 sqft.
30" STEEL PILES:
QTY. 1
1 TO BE INSTALLED ON LAND :
5 sqft
40'± STEEL LOADING RAMP
EXISTING ROCK BANK
P:\Y-2017\2017.0812\DWG\PERMIT\170812P04-11.DWG
PROPOSED MATTING
THREE 8' X 20' ARTICULATED
CONCRETE MATS
EXISTING PARKING
THESE DRAWING ARE TO BE USED FOR THE
ACQUISITION OF REGULATORY PERMITS ONLY
SCALE: 1" = 10'
DRAWN BY:
DATE:
10'
5'
0 CUBIC YARDS OF MATERIAL REMOVED
0'
10'
SJK
09/13/17
DRAWING NAME:
SHEET NO:
APPROVED BY:
JOB NO:
2017.0812
170812P01-02.DWG
9
OF
12
PROJECTION: LA SOUTH
GEO. DATUM: NAD83 | VERT. DATUM: NAVD88
GRID UNITS: US SURVEY FEET
REV. NO:
00
REV. DATE:
--/--/--
REV. BY:
---
JMH
REVISION DESCRIPTION:
--
EQUIPMENT DOCK/RAMP DETAIL
CHEVRON PIPE LINE COMPANY
PROPOSED INSTALLATION OF
A PERSONNEL DOCK & EQUIPMENT DOCK
FOURCHON TERMINAL
SECTION 24, T23S-R22E
LAFOURCHE PARISH, LOUISIANA
PROPOSED DOCK INSTALLATION
LOOKING NORTHWEST
20'
20'
PROPOSED PILE MOUNTED LIFT
GATE SUPPORTS
15'
15'
PROPOSED WINCH
MOUNTED ON SINGLE
30" STEEL PILING
10'
39'± PROPOSED BARGE DOCK
10'
PROPOSED PILE MOUNTED LIFT
GATE SUPPORTS
PROPOSED STEEL DECK
AND HANDRAIL
5'
5'
NATURAL GROUND
M.H.W. = 1.5'
M.L.W. = 0.0'
0'
-5'
0'
-5'
NATURAL BOTTOM
PROPOSED
MATTING
-10'
-10'
P:\Y-2017\2017.0812\DWG\PERMIT\170812P04-11.DWG
-15'
-15'
IMPACTS:
PROPOSED 12" DIA.
PILE LOCATIONS
8' X 20' CONCRETE MATS: QTY. 3
3 TO BE INSTALLED IN WATER:
480 sqft.
PROPOSED 12" DIA.
PILE LOCATIONS
0 CUBIC YARDS OF MATERIAL REMOVED
THESE DRAWING ARE TO BE USED FOR THE
ACQUISITION OF REGULATORY PERMITS ONLY
SCALE: 1" = 10'
DRAWN BY:
DATE:
10'
5'
0'
10'
SJK
09/13/17
DRAWING NAME:
SHEET NO:
APPROVED BY:
JOB NO:
2017.0812
170812P01-02.DWG
10
OF
12
PROJECTION: LA SOUTH
GEO. DATUM: NAD83 | VERT. DATUM: NAVD88
GRID UNITS: US SURVEY FEET
REV. NO:
00
REV. DATE:
--/--/--
REV. BY:
---
JMH
REVISION DESCRIPTION:
--
EQUIPMENT DOCK/RAMP PROFILE
CHEVRON PIPE LINE COMPANY
PROPOSED INSTALLATION OF
A PERSONNEL DOCK & EQUIPMENT DOCK
FOURCHON TERMINAL
SECTION 24, T23S-R22E
LAFOURCHE PARISH, LOUISIANA
PROPOSED MAT INSTALLATION
PROPOSED MAT INSTALLATION
OBLIQUE VIEW
LOOKING NORTHWEST
EXISTING GRAVEL PARKING LOT
A
RE
A
ING
A
MIN
E
G
TIN
XIS
AP
G
EX
TER
IN
IST
-R
RIP
EXISTING RIP-RAP EROSION CONTROL
P200600037
7
003
RK
A
LP
L
O
TR
06
P20
ON
OS
ER
C
ION
M.L.W. = 0.0'
PROPOSED MATTING
8'x20'x4.5", QTY:3
EDGE TO BE HAND JETTED
8'
CABLE TIES
WATER BOTTOM
8'
8'
8'
8'
EDGE TO BE HAND JETTED
20'
EDGE TO BE HAND JETTED
8'
EXISTING RIP-RAP WILL BE
REGRADED TO ALLOW FOR MAT PLACEMENT
WITH EDGES EMBEDDED IN THE BOTTOM 1.0'
EDGE BURIAL WILL TAKE PLACE BY HAND JETTING.
8'X20' MATS, QTY: 3
68' LINEAR FEET OF MAT EDGES TO BE JETTED
68' OF MATS X 1/2' WIDE X 1'BURIEL DEPTH = 34 CUBIC FT (1.26 CU.YDS.) OF JETTING
68' OF MATS X 1/2' WIDE = 34 SQFT (0.0007 ACRES) OF JETTING
9/25/2017 - P:\Y-2017\2017.0812\DWG\PERMIT\170812P04-11.DWG
TYPICAL MAT IDENTIFICATION TAG
CHEVRON PIPE LINE COMPANY
100 NORTHPARK BLVD
COVINGTON, LA 70433
CUP # P20170913
MAT NO. 1 OF 3
THESE DRAWING ARE TO BE USED FOR THE
ACQUISITION OF REGULATORY PERMITS ONLY
SCALE: 1" = 20'
DRAWN BY:
DATE:
20'
10'
0'
20'
SJK
09/13/17
DRAWING NAME:
SHEET NO:
APPROVED BY:
JOB NO:
170812P01-02.DWG
11
OF
12
PROJECTION: LA SOUTH
GEO. DATUM: NAD83 | VERT. DATUM: NAVD88
GRID UNITS: US SURVEY FEET
REV. NO:
00
REV. DATE:
--/--/--
REV. BY:
---
JMH
2017.0812
REVISION DESCRIPTION:
--
MATTING DETAIL
CHEVRON PIPE LINE COMPANY
PROPOSED INSTALLATION OF
A PERSONNEL DOCK & EQUIPMENT DOCK
FOURCHON TERMINAL
SECTION 24, T23S-R22E
LAFOURCHE PARISH, LOUISIANA
TYPICAL SHALLOW DRAFT TUG, BARGE, AND CRANE
600HP SHALLOW DRAFT TUG
120'x38' CRANE BARGE
5' DRAFT
5' DRAFT
120'±
50'±
CALCULATIONS:
EQUIPMENT LIST:
600 HP TUG 50' X 18' X 5' DRAFT
38' X 120' X 5' DRAFT CRANE/QUARTERS BARGE
30' X 130' X 3'-5' DRAFT DECK BARGE
ALUMINUM WORK SKIFF
APPROXIMATELY 9 SQUARE FEET OF THE FOURCHON TERMINAL GROUNDS MAY
BEAFFECTED BY PILINGS USED IN THE PROPOSED DOCK CONSTRUCTION
APPROXIMATELY 33 SQUARE FEET OF WATER BOTTOMS MAY BE AFFECTED BY PILINGS
USEDIN THE PROPOSED DOCK CONSTRUCTION.
APPROXIMATELY 480 SQ FT (0.01 ACRES) MAY BE AFFECTED BY THE PLACEMENT OF
4.5"ARTICULATED CONCRETE MATTING FOR EROSION CONTROL (6.67 CUBIC YARDS).
APPROXIMATELY 34 SQFT. (0.0007 ACRES) MAY BE AFFECTED BY HAND JETTING
APPROXIMATELY 1.26 CU. YDS. OF NATIVE MATERIAL MAY BE DISPLACED BY HAND JETTING
NO DREDGING OR WHEEL WASHING IS ANTICIPATED
NOTES:
AS-BUILT DRAWINGS AND/OR PLATS SHALL HAVE WRITTEN ON THEM THE DATE OF COMPLETION OF SAID ACTIVITIES AND SHALL BE SUBMITTED TO THE LOUISIANA
DEPARTMENT OF NATURAL RESOURCES, OFFICE OF COASTAL MANAGEMENT, P. O. BOX 44487, BATON ROUGE, LA 70804-4487 WITHIN 30 DAYS FOLLOWING PROJECT
COMPLETION.
ALL STRUCTURES BUILT UNDER THE AUTHORIZATION AND CONDITIONS OF THIS PERMIT SHALL BE REMOVED FROM THE SITE WITHIN 120 DAYS OF ABANDONMENT OF
THE FACILITIES FOR THE HEREIN PERMITTED USE, OR WHEN THESE STRUCTURES FALL INTO A STATE OF DISREPAIR SUCH THAT THEY CAN NO LONGER FUNCTION AS
INTENDED. THIS CONDITION DOES NOT PRECLUDE THE NECESSITY FOR REVISING THE CURRENT PERMIT OR OBTAINING A SEPARATE COASTAL USE PERMIT, SHOULD
ONE BE REQUIRED, FOR SUCH REMOVAL ACTIVITIES.
STRUCTURES MUST ALSO BE MARKED/LIGHTED IN ACCORDANCE WITH U. S. COAST GUARD REGULATIONS.
IN ORDER TO ENSURE THE SAFETY OF ALL PARTIES, THE PERMITTEE SHALL CONTACT THE LOUISIANA ONE CALL SYSTEM (1-800-272-3020) A MINIMUM OF 48 HOURS
PRIOR TO THE COMMENCEMENT OF ANY EXCAVATION (DIGGING, DREDGING, JETTING, ETC.) OR DEMOLITION ACTIVITY.
THESE DRAWING ARE TO BE USED FOR THE
ACQUISITION OF REGULATORY PERMITS ONLY
DRAWN BY:
DATE:
SJK
09/13/17
DRAWING NAME:
SHEET NO:
APPROVED BY:
JOB NO:
JMH
2017.0812
170812P01-02.DWG
12
OF
12
PROJECTION: LA SOUTH
GEO. DATUM: NAD83 | VERT. DATUM: NAVD88
GRID UNITS: US SURVEY FEET
EQUIPMENT/NOTES
CHEVRON PIPE LINE COMPANY
PROPOSED INSTALLATION OF
A PERSONNEL DOCK & EQUIPMENT DOCK
FOURCHON TERMINAL
SECTION 24, T23S-R22E
LAFOURCHE PARISH, LOUISIANA
REV. NO:
00
REV. DATE:
REVISION DESCRIPTION:
--
--/--/--
REV. BY:
---