You can copy from here when filling out the rest of the page.
Charlotte County, Vasco PGF Development LLC, Indianapolis, Florida
PROJECT PURPOSE: To construct 24 single family homes in Punta Gorda, Florida with associated seawall and 24 single family boat docks to allow residents recreational access.
Basic: Housing
Overall: To construct multiple single family residential developments with associated boat dock access and shoreline stabilization along the property.
TO WHOM IT MAY CONCERN: The Jacksonville District of the U.S. Army Corps of Engineers (Corps) has received an application for a Department of the Army permit pursuant to Section 404 of the Clean Water Act (33 U.S.C. §1344) and Section 10 of the Rivers and Harbors Act of 1899 (33 U.S.C. §403) as described below:
APPLICANT: Vasco PGF Development, LLC
c/o Mr. John B. Urbahns
7914 N. Shadeland Avenue, Suite 200
Indianapolis, Indiana 46250
WATERWAY AND LOCATION: The project would affect waters of the United States associated with Tarpon Canal which leads into Alligator Creek. The project area is located at 4000 Vasco Street, Punta Gorda, Section 19, Township 41 South, Range 23 East, Charlotte County, Florida.
Directions to project area: From I-75, take exit 161 and head west on Jones Loop Road to U.S. 41 (Tamiami Trail); make a right on U.S. 41; make a left on Rio Villa Drive; make a left on Vascot Street and arrive at project address on left.
APPROXIMATE COORDINATES:
Latitude: 26.900199 º
Longitude: -82.047246 º
PROJECT PURPOSE: To construct 24 single family homes in Punta Gorda, Florida with associated seawall and 24 single family boat docks to allow residents recreational access.
Basic: Housing
Overall: To construct multiple single family residential developments with associated boat dock access and shoreline stabilization along the property.
EXISTING CONDITIONS: The project area consist of disturbed land with an existing red mangrove (Rhizophora mangle) fringe that is infested by Brazilian pepper (Schinus terebinthifolia) along the Tarpon Canal system which is directly connected to Alligator Creek and Charlotte Harbor and consists of 7.30 acres.
The substrate in this area consists of soft mud bottom and has no benthic resources. The area surrounding the waterways consist of predominantly single-family residences, seawalls, boat docks, and some shorelines along the south side of Alligator Creek.
BACKGROUND: A Department of the Army (DA) (SAJ-2005-889) permit was issued on 8 April 2008 for 1,880 linear feet of seawall, installation of 1,902 linear feet of riprap, and the dredging of 1,457 cubic yards (cy) of sediment from the Tarpon Canal Waterways system to a depth of (-) 5 feet at Mean Low Water (MLW). This permit expired in April of 2013.
PROPOSED WORK: The applicant seeks authorization for a permit to:
1) Install 1,876 linear feet of seawall along the eastern boundary of the project, that will result in approximately 3,839 cubic yards of backfill above the Mean High Water Mark (MHWM) adjacent to the Tarpon Canal that will result in 0.06 acres of impact to mangrove wetlands within the man-made canal; and
2) Construct 24 single family docks measuring 8’ X 16’.
AVOIDANCE AND MINIMIZATION INFORMATION: The applicant has provided the following information in support of efforts to avoid and/or minimize impacts to the aquatic environment:
The seawall has been designed to avoid impacts to the mangrove fringe where feasible. The majority of the seawall will be constructed landward of the Mean High Water Line (MHWL) to avoid mangrove impacts. Due to site restraints and the need for minimum lot sizes, a portion of the seawall will be located waterward of MHWL, resulting in 0.06 acres of mangrove impact.
COMPENSATORY MITIGATION:
The applicant has provided the following explanation why compensatory mitigation should not be required:
Consistent with the previously approved permit, the applicant is proposing mitigation in the form of wetland creation which was previously constructed as a condition of the original permit. The approved UMAM analysis demonstrated that the proposed impacts will result in a loss of 0.04 functional units while the proposed mitigation will result in a gain of 0.10 functional units for a net increase of 0.06 functional units associated with the proposed impacts and mitigation.
CULTURAL RESOURCES: The Corps is not aware of any known historic properties within the permit area. By copy of this public notice, the Corps is providing information for review. Our final determination relative to historic resource impacts is subject to review by and coordination with the State Historic Preservation Officer (SHPO) and those federally recognized tribes with concerns in Florida and the Permit Area.
ENDANGERED SPECIES:
The Corps has determined that the proposed project will result in a “may affect, not likely to adversely affect” for the below-listed species.
1) Smalltooth sawfish (Pristis pectinata), the Green (Chelonia mydas), Kemp’s ridley (Lepidochelys kempii), Hawksbill (Eretmochelys imbricate), Leatherback (Dermochelys coracea) sea turtle, and the Threatened Loggerhead sea turtle (Caretta caretta).
The Corps has determined that the proposed project will result in a “may affect” on the smalltooth sawfish (Pristis pectinata) designated critical habitat. The Corps will request initiation of form consultation with the the National Marine Fisheries Service pursuant to Section 7 of the Endangered Species Act by separate letter.
2) West Indian (Florida) manatee (Trichechus manatus latirostris) and its designated critical habitat.
Using the Florida Effect Determination Key for the Manatee in Florida (April 2013), the U.S. Army Corps of Engineers (Corps) has determined the proposed project may affect the West Indian (Florida) manatee (Trichechus manatus latirostris) [A > B > C > G > H > I > J > L > N] determination for the West Indian manatee and its critical habitat. The Corps will request initiation of formal consultation for this species with the U.S. Fish and Wildlife Service (FWS) pursuant to Section 7 of the Endangered Species Act by separate letter.
ESSENTIAL FISH HABITAT (EFH): This notice initiates consultation with the National
Marine Fisheries Service on EFH as required by the Magnuson-Stevens Fishery
Conservation and Management Act 1996. The proposal would impact approximately 27.7 ac of water column, non-vegetated substrate utilized by various life stages of Red Drum, Reef Fish (43 species), Shrimp (4 species), and Coastal Migratory Pelagics. Our initial determination is that the proposed action would not have a substantial adverse impact on EFH or Federally managed fisheries in the Gulf of Mexico. Our final determination relative to project impacts and the need for mitigation measures is subject to review by and coordination with the National Marine Fisheries Service.
NOTE: This public notice is being issued based on information furnished by the applicant. This information has been verified and evaluated to ensure compliance with laws and regulation governing the regulatory program. The jurisdictional line has been verified by Corps personnel.
AUTHORIZATION FROM OTHER AGENCIES: Water Quality Certification may be required from the Florida Department of Environmental Protection and/or one of the state Water Management Districts.
Comments regarding the potential authorization of the work proposed should be submitted in writing to the attention of the District Engineer through the Fort Myers Permits Section, 1520 Royal Palm Square Boulevard, Suite 310, Fort Myers, Florida 33919 within 21 days from the date of this notice.
The decision whether to issue or deny this permit application will be based on the information received from this public notice and the evaluation of the probable impact to the associated wetlands. This is based on an analysis of the applicant's avoidance and minimization efforts for the project, as well as the compensatory mitigation proposed.
Questions concerning this application should be directed to the project manager, Allison Murphy in writing at the Fort Myers Permits Section, 1520 Royal Palm Square Boulevard, Suite 310, Fort Myers, Florida 33919, by electronic mail at Allison.C.Murphy@usace.army.mil, by fax at (239)334-0797, or by telephone at (239) 334-1975 extension 33.
IMPACT ON NATURAL RESOURCES: Preliminary review of this application indicates that an Environmental Impact Statement will not be required. Coordination with U.S. Fish and Wildlife Service, Environmental Protection Agency (EPA), the National Marine Fisheries Services, and other Federal, State, and local agencies, environmental groups, and concerned citizens generally yields pertinent environmental information that is instrumental in determining the impact the proposed action will have on the natural resources of the area. By means of this notice, we are soliciting comments on the potential effects of the project on threatened or endangered species or their habitat
EVALUATION: The decision whether to issue a permit will be based on an evaluation of the probable impact including cumulative impacts of the proposed activity on the public interest. That decision will reflect the national concern for both protection and utilization of important resources. The benefits, which reasonably may be expected to accrue from the proposal, must be balanced against its reasonably foreseeable detriments. All factors which may be relevant to the proposal will be considered including cumulative impacts thereof; among these are conservation, economics, esthetics, general environmental concerns, wetlands, historical properties, fish and wildlife values, flood hazards, floodplain values, land use, navigation, shoreline erosion and accretion, recreation, water supply and conservation, water quality, energy needs, safety, food, and fiber production, mineral needs, considerations of property ownership, and in general, the needs and welfare of the people. Evaluation of the impact of the activity on the public interest will also include application of the guidelines promulgated by the Administrator, EPA, under authority of Section 404(b) of the Clean Water Act of the criteria established under authority of Section 102(a) of the Marine Protection Research and Sanctuaries Act of 1972. A permit will be granted unless its issuance is found to be contrary to the public interest.
The US Army Corps of Engineers (Corps) is soliciting comments from the public; Federal, State, and local agencies and officials; Indian Tribes; and other Interested parties in order to consider and evaluate the impacts of this proposed activity. Any comments received will be considered by the Corps to determine whether to issue, modify, condition, or deny a permit for this proposal. To make this decision, comments are used to assess impacts on endangered species, historic properties, water quality, general environmental effects, and the other public interest factors listed above. Comments are used in the preparation of an Environmental Assessment and/or an Environmental Impact Statement pursuant to the National Environmental Policy Act comments are also used to determine the need for a public hearing and to determine the overall public interest of the proposed activity.
COASTAL ZONE MANAGEMENT CONSISTENCY: In Florida, the State approval constitutes compliance with the approved Coastal Zone Management Plan. In Puerto Rico, a Coastal Zone Management Consistency Concurrence is required from the Puerto Rico Planning Board, in the Virgin Islands, the Department of Planning and Natural Resources permit constitutes compliance with the Coastal Zone Management Plan.
REQUEST FOR PUBLIC HEARING: Any person may request a public hearing. The request must be submitted in writing to the District Engineer within the designated comment period of the notice and must state the specific reasons for requesting the public hearing.
DEPARTMENT OF THE ARMY
JACKSONVILLE DISTRICT CORPS OF ENGINEERS
1520 ROYAL PALM SQUARE BOULEVARD, SUITE 310
FORT MYERS, FLORIDA 33919
November 7, 2017
REPLY TO
ATTENTION OF
Regulatory Division
West Permits Branch
Fort Myers Permits Section
PUBLIC NOTICE
Permit Application Number SAJ-2005-00889 (SP-CMC)
TO WHOM IT MAY CONCERN: The Jacksonville District of the U.S. Army Corps of
Engineers (Corps) has received an application for a Department of the Army permit
pursuant to Section 404 of the Clean Water Act (33 U.S.C. §1344) and Section 10 of the
Rivers and Harbors Act of 1899 (33 U.S.C. §403) as described below:
APPLICANT:
Vasco PGF Development, LLC
c/o Mr. John B. Urbahns
7914 N. Shadeland Avenue, Suite 200
Indianapolis, Indiana 46250
WATERWAY AND LOCATION: The project would affect waters of the United States
associated with Tarpon Canal which leads into Alligator Creek. The project area is
located at 4000 Vasco Street, Punta Gorda, Section 19, Township 41 South, Range 23
East, Charlotte County, Florida.
Directions to project area: From I-75, take exit 161 and head west on Jones Loop Road
to U.S. 41 (Tamiami Trail); make a right on U.S. 41; make a left on Rio Villa Drive; make
a left on Vascot Street and arrive at project address on left.
APPROXIMATE COORDINATES:
Latitude: 26.900199 º
Longitude: -82.047246 º
PROJECT PURPOSE: To construct 24 single family homes in Punta Gorda, Florida
with associated seawall and 24 single family boat docks to allow residents recreational
access.
Basic: Housing
Overall: To construct multiple single family residential developments with associated
boat dock access and shoreline stabilization along the property.
EXISTING CONDITIONS: The project area consist of disturbed land with an existing
red mangrove (Rhizophora mangle) fringe that is infested by Brazilian pepper (Schinus
terebinthifolia) along the Tarpon Canal system which is directly connected to Alligator
Creek and Charlotte Harbor and consists of 7.30 acres.
The substrate in this area consists of soft mud bottom and has no benthic resources.
The area surrounding the waterways consist of predominantly single-family residences,
seawalls, boat docks, and some shorelines along the south side of Alligator Creek.
BACKGROUND: A Department of the Army (DA) (SAJ-2005-889) permit was issued on
8 April 2008 for 1,880 linear feet of seawall, installation of 1,902 linear feet of riprap, and
the dredging of 1,457 cubic yards (cy) of sediment from the Tarpon Canal Waterways
system to a depth of (-) 5 feet at Mean Low Water (MLW). This permit expired in April
of 2013.
PROPOSED WORK: The applicant seeks authorization for a permit to:
1)
Install 1,876 linear feet of seawall along the eastern boundary of the project, that
will result in approximately 3,839 cubic yards of backfill above the Mean High
Water Mark (MHWM) adjacent to the Tarpon Canal that will result in 0.06 acres
of impact to mangrove wetlands within the man-made canal; and
2)
Construct 24 single family docks measuring 8' X 16'.
AVOIDANCE AND MINIMIZATION INFORMATION: The applicant has provided the
following information in support of efforts to avoid and/or minimize impacts to the
aquatic environment:
The seawall has been designed to avoid impacts to the mangrove fringe where feasible.
The majority of the seawall will be constructed landward of the Mean High Water Line
(MHWL) to avoid mangrove impacts. Due to site restraints and the need for minimum
lot sizes, a portion of the seawall will be located waterward of MHWL, resulting in 0.06
acres of mangrove impact.
COMPENSATORY MITIGATION:
The applicant has provided the following explanation why compensatory mitigation
should not be required:
Consistent with the previously approved permit, the applicant is proposing mitigation in
the form of wetland creation which was previously constructed as a condition of the
original permit. The approved UMAM analysis demonstrated that the proposed impacts
will result in a loss of 0.04 functional units while the proposed mitigation will result in a
gain of 0.10 functional units for a net increase of 0.06 functional units associated with
the proposed impacts and mitigation.
CULTURAL RESOURCES: The Corps is not aware of any known historic properties
within the permit area. By copy of this public notice, the Corps is providing information
2
for review. Our final determination relative to historic resource impacts is subject to
review by and coordination with the State Historic Preservation Officer (SHPO) and
those federally recognized tribes with concerns in Florida and the Permit Area.
ENDANGERED SPECIES:
The Corps has determined that the proposed project will result in a "may affect, not
likely to adversely affect" for the below-listed species.
1)
Smalltooth sawfish (Pristis pectinata), the Green (Chelonia mydas), Kemp's
ridley (Lepidochelys kempii), Hawksbill (Eretmochelys imbricate), Leatherback
(Dermochelys coracea) sea turtle, and the Threatened Loggerhead sea turtle
(Caretta caretta).
The Corps has determined that the proposed project will result in a "may affect" on the
smalltooth sawfish (Pristis pectinata) designated critical habitat. The Corps will request
initiation of form consultation with the the National Marine Fisheries Service pursuant to
Section 7 of the Endangered Species Act by separate letter.
2)
West Indian (Florida) manatee (Trichechus manatus latirostris) and its
designated critical habitat.
Using the Florida Effect Determination Key for the Manatee in Florida (April 2013), the
U.S. Army Corps of Engineers (Corps) has determined the proposed project may affect
the West Indian (Florida) manatee (Trichechus manatus latirostris) [A > B > C > G > H >
I > J > L > N] determination for the West Indian manatee and its critical habitat. The
Corps will request initiation of formal consultation for this species with the U.S. Fish and
Wildlife Service (FWS) pursuant to Section 7 of the Endangered Species Act by
separate letter.
ESSENTIAL FISH HABITAT (EFH): This notice initiates consultation with the National
Marine Fisheries Service on EFH as required by the Magnuson-Stevens Fishery
Conservation and Management Act 1996. The proposal would impact approximately
27.7 ac of water column, non-vegetated substrate utilized by various life stages of Red
Drum, Reef Fish (43 species), Shrimp (4 species), and Coastal Migratory Pelagics. Our
initial determination is that the proposed action would not have a substantial adverse
impact on EFH or Federally managed fisheries in the Gulf of Mexico. Our final
determination relative to project impacts and the need for mitigation measures is subject
to review by and coordination with the National Marine Fisheries Service.
NOTE: This public notice is being issued based on information furnished by the
applicant. This information has been verified and evaluated to ensure compliance with
laws and regulation governing the regulatory program. The jurisdictional line has been
verified by Corps personnel.
3
AUTHORIZATION FROM OTHER AGENCIES: Water Quality Certification may be
required from the Florida Department of Environmental Protection and/or one of the
state Water Management Districts.
Comments regarding the potential authorization of the work proposed should be
submitted in writing to the attention of the District Engineer through the Fort Myers
Permits Section, 1520 Royal Palm Square Boulevard, Suite 310, Fort Myers, Florida
33919 within 21 days from the date of this notice.
The decision whether to issue or deny this permit application will be based on the
information received from this public notice and the evaluation of the probable impact to
the associated wetlands. This is based on an analysis of the applicant's avoidance and
minimization efforts for the project, as well as the compensatory mitigation proposed.
Questions concerning this application should be directed to the project manager, Allison
Murphy in writing at the Fort Myers Permits Section, 1520 Royal Palm Square
Boulevard, Suite 310, Fort Myers, Florida 33919, by electronic mail at
Allison.C.Murphy@usace.army.mil, by fax at (239)334-0797, or by telephone at (239)
334-1975 extension 33.
IMPACT ON NATURAL RESOURCES: Preliminary review of this application indicates
that an Environmental Impact Statement will not be required. Coordination with U.S.
Fish and Wildlife Service, Environmental Protection Agency (EPA), the National Marine
Fisheries Services, and other Federal, State, and local agencies, environmental groups,
and concerned citizens generally yields pertinent environmental information that is
instrumental in determining the impact the proposed action will have on the natural
resources of the area. By means of this notice, we are soliciting comments on the
potential effects of the project on threatened or endangered species or their habitat
EVALUATION: The decision whether to issue a permit will be based on an evaluation of
the probable impact including cumulative impacts of the proposed activity on the public
interest. That decision will reflect the national concern for both protection and utilization
of important resources. The benefits, which reasonably may be expected to accrue from
the proposal, must be balanced against its reasonably foreseeable detriments. All
factors which may be relevant to the proposal will be considered including cumulative
impacts thereof; among these are conservation, economics, esthetics, general
environmental concerns, wetlands, historical properties, fish and wildlife values, flood
hazards, floodplain values, land use, navigation, shoreline erosion and accretion,
recreation, water supply and conservation, water quality, energy needs, safety, food,
and fiber production, mineral needs, considerations of property ownership, and in
general, the needs and welfare of the people. Evaluation of the impact of the activity on
the public interest will also include application of the guidelines promulgated by the
Administrator, EPA, under authority of Section 404(b) of the Clean Water Act of the
criteria established under authority of Section 102(a) of the Marine Protection Research
and Sanctuaries Act of 1972. A permit will be granted unless its issuance is found to be
contrary to the public interest.
4
The US Army Corps of Engineers (Corps) is soliciting comments from the public;
Federal, State, and local agencies and officials; Indian Tribes; and other Interested
parties in order to consider and evaluate the impacts of this proposed activity. Any
comments received will be considered by the Corps to determine whether to issue,
modify, condition, or deny a permit for this proposal. To make this decision, comments
are used to assess impacts on endangered species, historic properties, water quality,
general environmental effects, and the other public interest factors listed above.
Comments are used in the preparation of an Environmental Assessment and/or an
Environmental Impact Statement pursuant to the National Environmental Policy Act
comments are also used to determine the need for a public hearing and to determine
the overall public interest of the proposed activity.
COASTAL ZONE MANAGEMENT CONSISTENCY: In Florida, the State approval
constitutes compliance with the approved Coastal Zone Management Plan. In Puerto
Rico, a Coastal Zone Management Consistency Concurrence is required from the
Puerto Rico Planning Board, in the Virgin Islands, the Department of Planning and
Natural Resources permit constitutes compliance with the Coastal Zone Management
Plan.
REQUEST FOR PUBLIC HEARING: Any person may request a public hearing. The
request must be submitted in writing to the District Engineer within the designated
comment period of the notice and must state the specific reasons for requesting the
public hearing.
5
PREPARED FOR:
"
0
-
-
......... F... J. ..O: ...R... L D,,.A ...................... ............... - ..
VASCO PGF DEVELOPMENT, LLC
7914 NORTH SHADELAND AVENUE, SUITE 200
INDIANAPOLIS, IN 46250
C Hl'PL Ol1E
PHONE: (317) 509-1368
- Clev·l·nd
'
"
"w
0
<
G 11
! I
~
INDEX OF SHEETS
UTILITY SERVICE PROVIDERS
I
Met/au
SHEET
WATER:
"'
"----""""'----'\
.
. . --...Cl<
CITY OF PUNTA GORDA
'
PHONE:
'\
·
326 W. MARION AVE.
PUNTA GORDA, FL 33950
(941) 575-3339
.. ,., .. · - - ·- - ·· ··--
SEWER:
CITY OF PUNTA GORDA
326 W. MARION AVE.
PUNTA GORDA, FL 33950
(941) 575-3339
HENDP '
-""
GENERAL LOCATION MAP
PHONE:
ELECTRIC:
FLORIDA POWER AND LIGHT
2245 MURPHY CT.
NORTH PORT, FL 34289
(941) 423-4851
PHONE:
PHONE:
CENTURY LINK
4195 KINGS HIGHWAY
PORT CHARLOTTE, FL 33980
(941) 637 - 5141
PHONE:
FIRE PROTECTION:
2657 1 AIRPORT ROAD
PUNTA GORDA, FL 33982
(941) 833-5600
CHARLOTTE COUNTY FIRE/EMS
PHONE:
SOLll:l WASTE OISEOSAL;
WASTE MANAGEMENT
1
2
3
4
5
6
7
8
9
TITLE
COVER SHEET
AERIAL PHOTOGRAPH
GENERAL NOTES AND LEGEND
SITE DEVELOPMENT PLAN
STORMWATER MANAGEMENT PLAN
PAVING, GRADING & DRAINAGE PLAN
PAVING, GRADING & DRAINAGE DETAILS
CROSS SECTIONS
BEST MANAGEMENT PRACTICES PLAN & DETAILS
25515 OLD LANDFILL RD.
PORT CHARLOTTE, FL 33980
(941) 629 - 1106
PHONE:
PROJECT CONTACTS
CIVIL ENGINEER:
BANKS ENGINEERING
TODD R. REBOL, P.E. PROJECT MANAGER
PHONE:
4161 TAM IAM I TRAIL - BLDG 5 UNIT 501
PORT CHARLOTTE, FLORIDA 33952
(941) 625-1165
SURVEYOR;
4161 TAM IAM I TRAIL - BLDG 5 UNIT 501
PORT CHARLOTTE, FLORIDA 33952
(941) 625-1165
BANKS ENGINEERING
RICHARD M. RITZ, RLS
PHONE:
ENVIRONMENTAL:
LOCATION MAP
SECTION 19, TOWNSHIP 41 SOUTH, RANGE 23 EAST
CHARLOTTE COUNTY, FLORIDA
IAN VINCENT & ASSOCIATES
IAN M. VINCENT
PHONE:
4050 ROCK CREEK DRIVE
PORT CHARLOTTE, FL 33948
(941) 457-6272
MARINE CONTRACTOR:
7017 RIVERSIDE DR IVE
PUNTA GORDA, FL 33982
(941) 623-2111
AUE CONSTRUCTION
PHONE:
SITE INFORMATION
EROJECT AREA:
7 .30 ACRES
PARCEL STRAP NO.:
41231913 4 00 1
EARCEL AQQRESS;
4000 VASCO STREET
PUNTA GORDA, FL 33950
CURRENT ZONING;
RSF3.5
PROPOSEO USE:
SINGLE FAMI LY RESIDENTIA L SUBDIVISION
BANKS
ENGINEERING
Professio nal Engin eers, Planners,
& Land Surveyors
Serving The State Of Florida
4161 TAMIAM I TRAIL -
BLDG 5 UNIT 501
PORT CHARLOTTE, FLORIDA 33952
PHONE: (941) 625 - 1165 FAX: (941) 625 - 1149
ENGINEERING LICENSE # EB 6469
SURVEY LICENSE # LB 6690
WWW.BANKSENG .COM
RONALD M. HAY, JR , P.E .
FLORIDA LICENSE #69163
NO.
DATE
REVISION DESCRIPTION
BY
BANKS
ENGINEERING
VASCO PGF DEVELOPMENT, LLC
7914 NORTH SHADELAND AVENUE, SUITE 200
INDIANAPOLIS , IN 46250
PHONE' {317) 509-1368
NO.
DATE
RE\t1SION DESCRIPTION
BY
Professional Engineers, Planners, & Land Surveyors
Serving The Sta le Of Florida
AERIAL PHOTOGRAPH
4161 TAM IAMI TRAIL - BLDG 5 UNIT 501
PORT CHARLOTTE, FLORIDA 33952
PHONE: (941) 625-1165
VASCO STREET
FA X: (941) 625-1149
CHARLOTIE COUNTY , FLORIDA
ENGINEERING LICENSE # EB 6469
SURVEY LICENSE # LB 6690
WWW.B ANKSENG.COM
RONALD M. HAY, JR., P.E.
FLOR IDA LICENSE #69163
DATE
PROJECT
DRAWING
DESIGN
DRAWN
CHECKED
SCALE
SHEET
5-1-2016
4065
_AER
RJE
RJE
RMH
1"=80 '
2
ABBREVIATIONS
ABO
AC
ACCEL
ADJ
AGG
ALT
ABANDONED
ACRE
GA
GAL
ACCELERATION
ADJUST
AGGREGATE
GALV
CAR
GB
ALTERNATE
GD
GIP
AM
APP L
APPROX
ALUMINUM
11:59 MIDNIGHT UNTll 12:00 NOON
APPLICATION
APPROXIMATE
ARY
AIR RELIEF VALVE
ALUM
ASPH
ASSEM
AT1N
AUX
AVE
AWG
BC
BCCMP
BE
BEG
BIT
BK
BL
BLC
BLDG
BLKHD
BLVD
BM
BNDRY
BOT
BP
BR
BRG
BT
BTFLY
BTWN
BW
C&G
GIP
CA
CAP
GASP
CATV
CB
CBC
CBS
cc
CD
CEM
CF
CFS
CH
Cl
CIP
CIRO
CL
CLEAR
CM
CMP
CMPA
co
COL
COM
COMP
CON
CONG·
CONST
CONT
CON TR
COORD
COR
CORR'
cov
CP
CPE
CR
CRS
CSP
CTR
CY
CULV
CWE
D
DIA
DA
DBH
DB I
DBL
DE
DEC EL
DEG
DELIN
DEPT
DET
DFE
DGN
DHW
DHWE
DHWL
DI
DIM
DIST
DR
DRWY
DS
DSWT
DT
owe
E
EOP
EA
EB
EL
EL AST
ELEC
ELLIP
EMBED
EMBK
ENCL
ENGR
EO
EQUIP
ERCP
ESMT
EST
E.STM
ETC
EW
EX
Exe
EXIST
EXP
EXT
FL
FS
FAG
FC
FD
FDN
FOOT
FE
FED
FES
FFE
FH
FIG
FIN
FLA
FLEX
FM
FOC
FR
FT
FTB
FURN
GM
GP
ASPH ALT
GR
GRC
GRD
ASSEMBLY
GTlR
ATTENTION
AUXILIARY
AVENUE
AMERICAN WIRE GAUGE
GV
BACK OF CURB
HS
HB
HG
HD
BITUM INOUS COATED CORRUGATED METAL PIPE HOPE
BURIED ELECTRIC
HOWL
HNDRL
BEGIN
BITUM IN OUS
HOA
BACK
HOR
BASELINE
HP
BASELINE CONTROL
HR
BUILDING
HSE
BULKHEAD
BOULEVARD
BENCHMARK
BOUNDARY
BOTTOM
BORROW PIT
BRIDGE
BEARING
BURIED TELEPHONE
BUTTERFL '(
BETWEEN
BOTTOM WIDTH
CURB AND GUTTER
CAST IN PLACE
COURSE AGGREGATE
CORRUGATED A LUMINUM PIPE
CORRUGATED ALUMIN IZED STEEL PIPE
CABLE TELEVISION
CATCH BASIN
CONCRETE BOX CULVERT
CONCRETE BOX STRUCTURE
CENTER TO CENTER
CROSS DRA IN
CEMENT
CUBIC FOOT
CUBIC FOOT PER SECOND
CHANNEL
CAST IRON
CAST IRON PIPE
CIRCU MFERENCE
CENTERLINE
CLEARANCE
CONCRETE MONUMENT
CORRUGATED METAL PIPE'
CORRUGATED METAL PIPE ARCH
CLEAN OUT
COLU MN
COMMERCIAL.
COMPOSITE
CONNECT
CONCRETE
CONSTRUCTION
CONTINUATION
CONTRACTOR
COORDINATE
CORNER
.CORRUGATED
COVER
CONCRE"TE PIPE
CORRUGATED POL YETiiYLENE P]PE
CONTROL RADIUS
COURSE
CORRUGATED STEEL PIPE
CENTER
CUBIC YARD
CULVERT
CONTROL WATER ELEVATION
DEPTii
DIAMETER
DRAINAGE AREA
DIAMETER AT BREAST HEIGHT
DI TCH BOTTOM INLET
DOUBLE
DRAINAGE EASEMENT
DECELERATION
DEGREE
DELINEATORS
DEPARTMENT
DETECTABLE
DESIGN FLOOD ELEVATION
DESIGN
DESIGN HIGH WATER
DESIGN HIGH WATER ELEVATION
DESIGN HIGH WATER LEVEL
DROP INLET
DIMENSION
DISTANCE
DRIVE
DRIVEWAY
DESIGN SPEED
DRY SEASON WATER TABLE
DI TCH
DRAWING
EAST
EDGE OF PAVEMEN T
EACH
EASTBOUND
ELEVATION
ELASTOMERIC
ELECTR IC
ELLIPTICAL
EMBEDMENT
EMBANKMENT
ENCLOSURE
ENGINEER
EQUAL
EQUIPMEN T
ELLIPTICAL REINFORCED CONCRETE PIPE
EASEMENT
ESTABLISHED
ESTIMATE
ET CETERA.
ENDWALL
EXCEPT
EXCAVATION
EXISTING
EXPANSION
EXTENSION
FLOWLINE
FLOR IDA STATUTES
FLOR IDA ADMINISTRATl\/E CODE
FRICTION COURSE
FRENCH DRAIN
FOUNDATION
FLOR IDA OEPARTMEN_T OF TRANSPORTATION
FLOOR ELEVATION
FEDERAL
FLARED E,NO SECTION
FINISHED FLOOR ELEVATION
FIRE HYDRANT
FIGURE
FINISH
FLOR IDA
FLEXIBLE
FORCE MAIN
FIBER OPTIC CABLE
FRAME
FOOT OR FEET
FLOATING TURBIDITY BARR IER
FURNISH
HT
HW
HWY
HYO
HZ
ID
IN
INC
IND
INSTALL
INT
INV
IP
IR
ISECT
ISL
JB
JCT
JT
K
KWH
L
L/W
LA
LAT
LB
LB/SY
LBR
LF
LGTH
LIN
LM
LME
LMRK
LOC
LONG
LS
LSB
LT
LTD
LUM
LX
MAINT
MA TL
MAX
MB
MED
MES
MFG
MH
MHW
Ml
MID
MIL
MIN
MISC
MJ
MLW
MOBL
MOD
MON
MOT
MP
MPH
MSL
MTD
MUTCD
N
N&C
N&D
NA
NAVO
NB
NE
NEMA
NGVD
NHW
NIC
NO
NOM
NORM
NTS
NW
NWL
OBG
QA
QC
OD
OE
OH
OPT
OT
PAR
PAVT
PC
PCBC
PCE
PE
PED
PEN
PG
PGL
PH
Pl
PKG
PKWY
PL
PM
POC
pp
PR
PRC
PR CST
PREST
PRM
PROD.
PROJ
PROP
PSF
PSI
PSU
PT
PUE
PVC
PW
Q
·R
RT
ROW
RC
GAUGE
GALLON
GALVANIZED
GARAGE
GRADE BREAK
GUTIER DRAIN~
GALVANIZED IRON PIPE
GAS MAIN
GRADE POINT
GRADE OR GRATE
GALVANIZED RIGID CONDUIT
GROUND
GUTTER
GATE VALVE
HIGH STRENGTH
HAY BALES
HANDICAPPED OR HORJZONTAL CLEARANCE
HEAVY DU TY
HIGH DENSITY POLYETHYLENE
HEADWALI_
HANDRAIL
HOME OWERS ASSOCIATION
HORIZONTAL
HIGH POINT OR HIGH PRESSURE
HOUR
HOUSE
HEIGHT
HIGH WATER
HIGHWAY
HYDRAU LI C
HERTZ
INSIDE DIAMETER OR: IDENTIFICATION
INCH(ES)
INCORPORATED OR INCLUDING
INDUSTRY
INSTALLED
IN TERIOR
INVERT
IRON PIPE
IRON ROD
INTERSECTION
ISLAND
JUNCTION BOX
JUNCTION
JOINT
DESIGN HOUR FACTOR
KILOWATT-HOUR
LENGTH
LIGH TWEIGHT
LIMITED ACCESS
LATITUDE
POUNDS
POUNDS PER SQUARE YARDS
LIME ROCK BEARING RATIO
LINEAR· FEE T (FOOT)
LENGTH
LINEAR·
LUMEN
LAKE MAINTENANCE EASEMENT
LIME ROCK
LOCATION
LONGlnJOE
LUMP .SU M OR LANDSCAPE
LANDSCAPE BUFFER
LEFT TURN
LIMITED
LU MIN AIRE
LUX
MAIN TENANCE
MATER IAL.
MAXIMUM
MEDIAN BARRIER
MEDIAN
MITERED ENO SECTION
MANUFACTURER
MANHOLE
MEAN HIGH WATER
MILE
MIDDLE
ONE-THOUSANDTH OF AN INCH
MIN IMUM
MISCELLANEOUS
MECHANICAL JOIN !
MEAN j_OW WATER
MOBILIZATION
MODIFIED
MONUMEN T
MAINTENANC~ OF TRAFf(C
MILE POST
MILES PER HOUR
MEAN SEA LEVEL
MOUNTED
MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES
NORTH
NAIL AND CAP
NAIL AND DISK
NOT APPLICABLE
NATIONAL AMERICAN VERTICAL DATUM
NORTHBOUND
NORTHEAST
NATIONAL ELECTRIC MANUFACTURES ASSOCIATION
NATIONAL GEODETIC VERTICAL DATUM OF 1929
NORMAL HIGH WATER
NOT IN CONTRACT
NUMBER
NOMINAL
NORMAL
NOT TO 'SCALE
NORTHWEST
NORMAL WATER LEVEL
OPTIONAL BASE GROUP
OVERALL
ON CENTER
OUTSIDE DIAMETER
O\/ERHEAD ELECTRIC
OVERHEAD
OPTIONAL
OVERHEAD TELEPHONE
PARALLEL
PAVEMENT
POINT OF CURVATURE
PRECAST CONCRETE BOX CULVERT
PERMANENT CONSTRUCTION EASEMENT
PROFESSIONAL ENGINEER
PEDESTRIAN
PENETRATION
PROFILE GRADE
PROFILE GRADE Uf\!E'
PHASE
POINT OF INTERSECTION
PARKING
PARKWAY
PROPERTY LINE
12:00 N001'{ UNTIL 11'.59 MIDNIGHT
POINT OF CONNECTION OR POINT OF CURVE
POWER POLE
PAIR
POINT OF REVERSE CURVATURE
PRE CAST
PRESTRESSED
PER MANENT REFERENCE MONUMENT
PRODUCT
PROJECT
PROPOSED
POUNDS PER SQUARE FOOT
POUNDS PER SQUARE INCH
PRESTRESSED SLAB UNIT
POINT OF TANGENCY
PUBL!C UTILITY EASEMENT
POLYVINYL CHLORIDE
POTAB LE WATER
PEAK DISCHARGE OR FLOW VOLUME
RADIUS
RIGHT
RIGHT OF WAY
REVERSE CROWN
PREPARED FOR:
RCP
RCPA
RD
ROSO
RD WY
REC
RECT
REF
REFL
REG
REINF
RELOC
REM
RED
REPL
REQ
RES
RM
RP
RPM
RR
RSF
SAN
SB
SCH
SO
SE
SECT
SEO
SEP
SG
SHT
SHLDR
SHW
SHWT
SP
SPEC
SQ
SF
SQ IN
SY
SR
SS
ST
STA
STAB
STB
STD
STGE
sn_
STR
STY
SUB
SUBST
SUPPTS
SUR
SURF
SW
~~A
SYS
TWP
~~N
TCE
TEL
TEMP
TK
'Tii lCK
~
TON
+g~
:~~ T
TW
TYP
UE.
UG
UL
UNODR
USGS
~~L
~AR
VC
0~~
'VERT
0~L
~/
TOP OF BANK
TOE OF SLOPE
TRAFFIC
TREATMENT
TOP OF WALL
TYPICAL
UTILI TY EASEMENT
UNDERGROUND
UNDER'h'RITERS LABORATORIES
UNDER DRAIN
UNITED STATES GEOLOGICAL SERVICE
UTILI TIES
ULTRAVIOLET
VOLT
VARIES
VERTICAL CURVE
VITRIFIED CLAY PIPE
VEHICLE
VERTICAL
VOLUME
VARIABLE WIDTH
WIDTH OR WATT
"1TH
WB
WM
WSWT
WT
WWF
WWR
~~E~
YD
YR
REINFORCED CONCRETE PfPE
REINFORCED CONCRETE PIPE ARCH
ROAD
ROADSIDE
ROADWAY
RECREATIONAL
RECTICULINE
REFERENCE
REFLECTIVE
REGISTERED
REINFORCED
RELOCATED
REMOVAL
REDUCER
REPLACE
REQU'IRED
RESIDENCE' OR RESIDENTIAL
RE-USE MAIN OR REFERENCE. MONUMEN T
REFERENCE POINT
RAISED REFLECTIVE PAVEMENT MARKERS
RAILROAD
RESURFACE
SANITARY
SOUTHBOUND
SCHEDULE
STORMDRAIN
SOUTHEAST
SECTION
SEDI MENT
SEPARATION
SUBGRADE
SHEET
SHOULDER
SEASONAL HIGH WATER
SEASONAL HIGH WATER TABLE
SUPER PAVE
SPECIFICATION
SQUARE
SQUARE FOOT
SQUARE !NCH
SQUARE YARD
STATE ROAD
SANITARY SEWER OR STAINLESS STEEL
STREET
STATION
STABILIZATION
STAKED TURBIDITY BA R R I E~
STANDARD
STORAGE
STEE L
STRUCTURE
STORY
SUB SOIL
SUBSTITUTE
SUPPORTS
SURVEY
SURFACE
SIDE WALK OR SOUTHWEST
STORM WATER, MANAGEMENT AREA
SYM METRIC AL
SYSTEM
TOWNSHIP
TANGENT
TANGENT TO CUR\/E:
TEMPORARY CONSTRUCTION EASEMENT
TELEPHONE
TEMPORARY
TRUCK
TiilCKNESS
TRAFFIC IMPACT STATEMENT
WESTBOUND
WATER MAIN
WE T SEASON WATER TABLE
WATER TABLE
WELDED WIRE FABRIC
WELDED WIRE REINFORCING
CROSSING
CROSS SECTION
YARD
YEAR
1.
2.
.3.
4.
GENERAL SPECIFICATIONS:
SITE DATA TABLE:
ALL CONSTRUCTION TO BE l N ACCORDANCE WITH FLORIDA DEPT. OF
TRANSPORTATION (F.0.0. T.) STANDARD SPECIFICATIONS FOR ROAD &
BR IDGE CONSTRUCTION, CURRENT .EDITION.
PROPERTY AREA:
PROJECT AREA (DRAINAGE BASIN):
CURRENT 'ZONING AND LAND USE:
PROPOSED USE:.
THE CONTRACTOR SHALL SUPPLY SATISFACTORY DENSITY TESTS OF
SUBGRADE & LIMEROCK BASE MATERIALS TO THE ENGINEER PRIOR
TO PAYMENT &/OR FINAL ACCEPTANCE. ONE TEST PER COURSE
PER 6QO SQUARE YARDS.
LEGEND
7. 30 ACRES
5.25 ACRES
RSFJ.5 / VACANT
EXISTING
SINGLE FAMILY RESIDENTIAL SUBDIVISION
-------------
DRAINAGE PIPE
n @Jcs
LANDUSE BREAKDOWN:
ALL REINFORCED CONCRETE PIPE (RCP) CULVERTS SHALL MEET
ASTM C 76, CLASS Ill, TYPE "B" WALL FOR ROUND PIPE & MEET
ASTM C 507, TABLE I FOR ELLIPTICAL PIPE & OTHERWISE BE
INSTALLED & MANUFACTURED IN ACCORDANCE WITH F.0.0.T.
SECTIONS 430 & 9 4 1.
PROPERTY A REA:
PROJECT AREA (DRAINAGE BASIN):
RESIDEN TIAL TRACTS:
TRACT A ~
[
EXISTING FILTER MARSH EASEMENT:
MANMADE CANAL:
(1003)
7 ,30 AC
5.25 AC (71.9%)
5_05 AC
0.20 AC
0.36 AC (4.9%)
1. 69 AC (23.23)
b
t
CONTRACTOR SHALL l?ROVIDE & MAINTAIN TRAFFIC CONTROL IN
ACCORDANCE WITH F,D.b.T, ROADWAY & TRAFFIC DESIGN
STANDARDS CURRENT EDITION & THE FEDERAL. HIGHWAY
ADMINISTRA TION'S MANUAL ON UNIFORM TRAFFIC CON TROL DE VICES
(MUTCD), CURRENT EDITION .
5.
CONTRACTOR SHALL SEED & MULCH ALL DIS1URBED AREAS &
OTHERWISE RESTORE ALL AREAS TO EXISTING CONDITION OR
BETTER .
6.
ALL PAVEMENT STRIPING TO BE TWO COATS OF HEAVY DUTY
ACR'l'llC BASED TRAFFIC PAINT.
7.
ALL TR AFFIC SIGNS TO BE DRIVEN STEEL POST TYPE GROUND SIGNS
IN ACCORDANCE WITH F.D.O. T. INDEX DRAWINGS 1'1860 & 11863 (BO
M.P.H , IMND LOAD) & F.D .O.T. SPECIFICATIONS SECTION
700-HIGHWAY SIGNING.
PROPOSED
t
DRAINAGE STRUCTURES
C_lml "JCC
( 100%)
(96.2%)
( 3.83)
~Os
CT?JCCJ
<§>
FI NISHED FLOOR ELEVATION
N/A
DN-SITE STORM STRUCTURE NUMBER
N/A'
@
OFF-SITE STORM STRUCTURE NU MBER
N/A
c:§
SPOT GRADE ELEVAllON
TOP OF BERM
8.
FLOOD ZONE:
2.
ALL WORK SHOWN BY INDEX NO. SHALL BE IN ACCORDANCE IMTH
F.D.O.T. ROADWA Y & TRAFFIC DESIGN STANDARDS CURRENT EDITION.
CONTRACTOR SHALL MAINTAI N A CURRENT ANO UPDATED SET OF
AS-BUil T DRAWINGS AT ALL TIMES AND PROVIDE ONE COPY TO THE
ENGINEER UPON COMPLETION OF CONSTRUCTION.
ALL BACKFILL SHALL BE COMPACTED IN STRICT ACCORDANCE W'ITH
THE: BEDDING DETAILS.
4 ..
CONTRACTOR SHALL COORDINATE ALL WORK IN THE COUNTY
RIGHT-OF-WAY WITH THE' CHAR LOTTE COUNTY D.O.T.&E.
5 ..
UNIT BREAKDOWN:
ALL EXISTING AND PROPOSED ELEVATIONS REFERENCE THE NAVO 88
DATUM.
3.
SINGLE FAMILY DETACt-JED (80'X150')
24
TOTAL UNITS;
24
L _ _ _, _
_J
PAVEMENT TO BE REMOVED
l rtrnl[tll
CONCRETE
c==J
I
I
N/A
1------1
RIGl-JT-OF-·WA Y
DEVELOPMENT STANDARDS:
CURB
=====
EASEMENT
------
=
SWALE/DITCH
RSF-3.5
ALL REINFORCED CONCRETE PIPE (RCP) CULVERTS SHALL MEET ASTM
C 76, CLASS Ill, TYPE "B" WALI_ FOR ROUND PIPE AND MEET ASTM C
507, TABLE I FOR ELLIPTICAL PIPE AND OTHERW'ISE BE INSTALLED
AND MANUFACTURED IN ACCORDANCE IMTH F.D.0. T, SECTIONS 430 &
941.
6.
ALL ROOF TOP DRAINS ARE TO BE DIRECTED TO DRAINAGE AREA.
7,
CONTRACTOR SHALL SOD OR SEED & MULCH ALL DISTURBED AREAS
ON-SI TE AND OTHERWISE RES TORE. ALL AREAS TO EXISTING
CONDITlON OR BETIER.
8.
SOD ALL SWALE AND TREATMENT AREAS.
9.
CONTRACTOR SHALL SOD ALL DISTURBED AREAS WITHIN THE COUN TY
RIGHT - OF-WAY
SINGLE Fl\MILV
DETl\TCHED
DESCRIPTION
PROPOSED
# OF
UNITS
- -7- --T --
TOP OF BANK
24
LAKE
REQUIRED PARKING
2 / UNIT
MIN. LOT REQUIREMENT (SD. FT.)
10,000
WIDTH (FT,)
10. THE GRADES REPRESENT THE FINISHED GRADE. ON TOP OF THE SOD.
25
SIDE YARD
INTERIOR {FT.)
7.5
SIDE YARD
ASUnlNG I\ ROAD {FT.)
13. THE PR6P6SED MlfERED END SECTIONS WITiilN COUNTY RIGHT 6F
WAY, SHALL EXTEND BEYOND THE PROPOSED EDGE OF PAVEMENT A
MINIMUM OF 6'-0" .
14. CONTRACTOR RESPONSIBLE FOR WATERING AND MOWING OF SOD
PLACED IN THE ROW UNTJL ESTABLI SHMENT AND FINAL ACCEPTANCE
BY THE COUNTY.
L ____
_J
I
I
lx)l/-IETLANDS
--l
1--t----1
1-- - ll_--
-is
POTABLE WATER LINE
1 - - -ES"W - - - I
- ..
MAX. BUILDING HEIGHT {FT,)
38
FORCE MAIN
1 - - -ES'"F - - - I
MIN. REAR YARD
ABUTTING A LOT {FT.)
t---B"F---1
20
SANITARY SEWER MAIN
1---Ea"ss - - - 1
1----s_··ss:---1
IRRIGATION WATER MAIN
l - - - E8'"1- - - I
1 - - -8"1 - - - - l
REUSE WATER MAIN
1---- EB"RU - - - I
1 - - -B"RU- - - I
t.llN. REAR YARD
ABUnlNG I\ ROAD {FT.)
SElBACK FOR ACCESSORY ·SlRUCTURE
FROM REAR LOT UNE (FT.)
12. SHOP DRAWINGS ARE REQUIRED FOR ALL STRUCTURES.
STORMWATER MANAGMENT AREA (DRY)
80"
FRONT YARD (FT.)
,-----,
PROPERTY LINE
11 , A RIGHT-OF-WAY USE PERM IT VV!LL BE REQUIRED FOR ALL WORK
W1THIN RIGHT- OF-WAY,
25
10
SElBACK FOR ACCESSORY STRUCTURE
FROIA SIDE YARD (FT.)
Sl\t.lE AS PRINCIPAL BUiLDING
SElBACK FOR ACCESSORY 'STRUCTURE
ABUffiNG ROAD R.0.W. (FT.)
SAt.lE AS Pf!INCIPAL BUILDING
GATE VALVE
1S. Ci.JRB ELEVATIONS SHO WN ARE FOR THE LO W SIDE OF TiiE CURB
UNLESS OTiiERWISE NOTED.
-
REDUCER
16. ALL SLOPES TO BE 4; 1 MAXIMUM .
17. ALL FILL MATERIAL USED FOR DRY" RETENTION SHALL BE CLE AN
SANDY MATERIAL WITH A PERMEABILITY RATE BETWEEN 6 AND 20
INCHES PER HOUR MINIMUM. COMPACTION SHALL BE MINIMIZED IN
THE RETENTION AREA TO THE GREATEST EXTENT PRACTICAL DURING
CONSTRUC TION ,
1?. ALL WORK SHOWN BY INDEX NO. SHALL 8E IN ACCORDANCE WIJH
F.. D.O.T. ROADWAY & TRAFFIC DESIGN STANDARDS, LATEST ED ITION.
PARKING CALCULATION:
BLOW- OFF
SINGLE FAMILY RESIDENTIAL
REQU IRED:
2.0 SPACES PER DWELLING UNIT
(24 UNITS) X (2.0)
=48 SPACES
AIR RELEASE VALVE
PROVIDED:
BMP GENERAL NOTES:
-
FIRE HYDRANT ASSEMB LY
2.0 SPACES PER. DWELLING UNIT
(24 UN ITS) X (2 .0)
=48 SPACES
SINGLE WATER SERVICE
DOUBLE WATER SERVICE
SCHEDULE OF BMP IMPLEMENTATION:
1.
,----,
PAVEMENT
DRAINAGE GENERAL NOTES:
1.
RUBBLE RIP- RAP
PARCEL LIES: IN FLOOD ZONE 9AE' (EL, 9 . 0 NGVD 1929)
FEMA FLOOD MAP 12015C0243F DATED 5/5/2003
INSTALL ALL TEMPORARY BMP MEASURES PRIOR TO ST ART OF
CONSTRUCTION ..
TOTAL REQUIRED SPACES:
48 SPACES
TOT Al PROVIDED SP ACES:
48 SPACES "'
·
2.
IN STALL ALL PER MANENT 8,MP MEASURES IMMEDIATELY AFTER FINAL
GRADING.
3.
REMOVE TEMPORARY BMP FEA TURES AS APPLICABLE.
-' -
SINGLE IRR IGATION SERVICE
SPACES ARE PROVIDED !MTHIN PROPOSED DRIVEWAYS
DOUBLE IRRIGATION SERVICE
SINGLE SEWER SERVICE
PROJECT INFORM.ATION:.
y
DOUBLE SEWER SERVICE
1.
THIS PROJECT PRESENTS' NO ADVERSE IMPACTS ON LOCAL GROUNDS
OR SURFACE WATERS, ANO DOES NOT ADVERSEL Y IMPACT THE
FLOOD ZONE,
2.
THIS SITE CAN BE USED FOR THE DEVELOPMENT AS SHOWN.
WITHOUT UN IQUE DANGER FROM FLOOD, ADVERSE SOIL, AND/OR
FOUNDATION CONDITIONS, SUBJEC.T TO PROPER· GEOTECH.NICAL
INVESTlGATION, SITE DESIGN, AND STRUCTURE DESIGN ,
.3.
THE PROJECT DOES NOT IMPACT ANY KNO WN (JN MITIGATED
WETLANDS.
4,
NO KNO WN ARCHAEOLOGICAL SITES EXIST WlTHIN THE' PROJECT AREA.
5 ,,
THE CONTRACTOR SHALL SUPPLY BA THYMEJRIC SURVEY ON ALL
LAKES GREATER THAN 12"' DEEP PRIOR TO FINAL ACCEPTANCE,
y
SANITARY MANHOLE & 10
i-------1- ()o-
LIFT STATION & ID
NOTES:
L
SURVEY LOCATION INFORMATION PROVIDED BY BANKS ENGINEERING INC.
2.
TOPOGRAPHIC POiNTS WERE OBTAINED FROM CHARLOTTE" COUNTY GIS AND
ELEVATIONS ARE BASED ON NORTH AMERICAN VERTICAL DATUM OF 1988
(NA\/088)
3.
PRIOR TO EXCAVATION
CONTACT SUNstilf'E STATE ONE
- CALL OF R.OAJDA
1 (800) 432 - 4770
A SEPARATE RIGHT-OF-WAY IJSE PERMIT WlLL BE REQUiRED FOR ALL
UTILI TY WORK WITiilN THE .PUBLIC RIGHT- OF-WAY. SPECIFIC STIPULATlONS OR
CONDITIONS WILL BE IMPOSED A THE TIME OF PERMIT APPLICATION.
CONTRACTOR SHALL SUBMIT FOR NPD.E.S. PEFMT
A Mital.JM OF 48 HOl..RS PRIOR TO OONSlllJCTION,.
4.
All SIDEWALKS SHALL MEET ADA STANDARDS.
PERMIT APPLICATION SHALL BE SU~ TO:
5.
ALL SIDEWALKS .SHALL NOT EXCEED 23 CROSS SLOPE.
NPD.E.S. STORM'NAlCR NOTICES aNTS\ MS t 2510,.
R..ORDA DEPARTMENT OF EtMRONMENTAL PROTECTION
.2600 EILAFI STOtE ROAD,
TAL.l..AHASSEE, R..ORDA
32399-2400
BANKS
ENGINEERING
VASCO PGF DEVELOPMENT, LLC
79 14 NORTH S HAD ELAND A V ENUE, SUITE 200
IND IANAPOLIS , IN 46250
PHONE; (317) 509-1368
NO.
DAIT
REV1SION DESCRIPTION
BY
Professional Eng ineers, Pla nners, & Land Surveyors
Serving The State O f Florida
GENERAL NOTES AND LEGEND
4161 TAMIAM I TRAIL - BLDG 5 UNIT 501
PORT CHARLOTTE, FLORIDA 33952
PHONE: (941) 625-1 165 FAX: (941) 625~1149
VASCO STREET
ENGINEERING LICENSE fl EB 6469
SURVEY LICENSE fl LB 6690
CHARLOTTE COUNTY, FLORIDA
WWW.BANKSENG.COM
RONALD M. HAY, JR. , P.E.
FLORIDA LICENSE #69163
DATE
PROJECT
DRAWi.NG
DESIGN
DRAWN
C HECKED
SCALE
S HEET
5- 1 -20 16
4065
_GEN NT
RJE
RJE
RMH
N/A
3
0
I
l
I
-1
-
I
I
I
11 I
I
Il
r--.[::-_ _/. I
-
I
I
I
I
I
I
\\
~ ~~
t---..~="~;
____ __ l_J
_ ___ __ J
ffDRAINAGE
TYPlf.Al -
~1:t-~_:__
I
85'
::' I
t-:,:~~~RACT
-
-
:1
:
sr
j_
1
~----~~-- l_ J 1 ~
"A"
~
_j
I ------~· -_-----
0
l~
''
-
--
~-=--:=::=.._ -
-
I
... --!-
-;-"""---:::t -
\
----
I
~
-
.--90
1
I
I
l
-- -
- -
EXISTING SEAWALL
1 " ~ 40'
-r -
120'
··
PROPERTY LINE\
78'
74'
77'
·
25'
TYP
: :- -- l
11
I
! !
65'
!
1
I
I
II
: I
I.
19
1·0
1 ::'
I
1
18
I I!
65'
!
65'
I
I
65'
I
_j
I1
10·
L ____
I
-
-
-
11
1
I I
1
17
l ~I
16
1 ~_
I
15
65'
I
I
65'
I
I
65'
i
I
i
I
i
-
n----
I
l -0
1
= = -=+1--t=+I
T ----~
I , _,I _----~-',II
I
1·0
I
I~
I
I
II
i:11
1,.
l
I
: --
I
I
I·
14
1
II
i=
-
Jj.
--:-,
I
: :;;;-
··
:
13
65'
>l_
65'
l
_
_____
lJ
L______ UI l ______u L____ __ u c~y~---- 11 ~~s;~~~~~--u u-----i~
-- n
L ______ n
n
I
75'
71
1
'
:
57
:
1I
'
66 '
1
66'
,~-----_J
I
BO'
--
I~
1-
---~~
+-+1:
II
E
II
t ~:- - - --'~~6:1
~
2 'f-1
. -Fr;-+
l ___
11
20
1\
lr-------
~-~
1
1
8'x16'
DOCK
ff OTHERS-...._
SEAWALL
(TYPj ,._,,,
"\. ,.., BY OTHERS
WATER:\
MEAN HIGH
I
1
11
80
-- --- --- -
I
- DRAINAGE: EASEMENT
TYPICAL
SE.AWALL IBY OTHERS\
I
___lJ l ~~~~~~~--u
r~~
22 _ _
1
~
::,
76'
EX. TOE OF I SLOP( \ \
lr--.1
I
10'
EX. TOP OF BANI<-=\
I
1I
I
20'
TYP
I
"
I
~
I
:. i
Ll __ TI
J~
23 _ _ _ _
I
.Lf---1
65'
i
I
I
I
!.
I 1 s3·
L
TARPON CANAL
""'~I
I
(TYP)
~+r_J__ I~
----1- (..,,. .-
75'
80'
I
7 5
11 11
65'
.
,~-----_J
so·
BO'
I
BO'
I
10·
I
65'
;
I wl
s5'
~_L _____
BO'
.~ ,
BO'
j
BO'
I
·
:;;:
I
-
-------- ---- - ----- =~~ ----- -- -- --- -
-
1+00
- - - + - -- - - - - + - - - -
~-
I
- -- ---- - - - ·- - - - ~ 1- -~- - -
I
-
....-
I
r'l
~{"':::~~ i i
:u___
-
MEAN HIGH WATER
OTHERS ·~
E f¥'
MEAN HIGH WAITER\
j&~~~~ ----
--:::: ---
I1
I
l
~ ~...--::
I
----- ----
· --
63'
<.a
' I
I
I
I
·-
GRAPH IC SCALE
DOCK
~
t1
\.
-
-- ---
·-
80'
B'x16'
'i
LJNE
-
~E~
-
EASEMENT~ :
~SEAWALL
EXISTING Fll TER MARSH
_[ -
-
MEAN HIGH WA TER
63'
-::dBEGIN ~
-
-~
- -
STATION I 30 .
\¢I jEASEMENr
j
1
I
0+00
~
-
I I
I
I
-
-....:::::---.:=::---- :::::---._ ~ '
------ ------ -=___......-
I
1
: 1
l
-
' - ---.._
11
I
-
~ .
1 11_
1-
EXISTING SEAWALL
-- - -
40'
'
'
'
'
-
t-, ___
_j
·
±16'
·
'
-
+-
'
12' DRAINAGE E'ASEMENT TYPICAL-
'
'
r-----
'
EX. TOE OF SLOPE'- 'I
EX. TOP OF BANK_;
. VASCO STREET.
12' DRAINAGE EASEMENT TYPICAL-
I
-
60' RIGHT OF WAY
, -------------------~-----------J----------~---------------------~ ------ - ---- ,
----------------
50' RIGHT OF WA Y
'
I
---~~
'
'
'
'
'
±15'
12' DRAINAGE EASEMENT TYPICAL -
'
'
I
-- ~--- ----- ~------ -+---- ~ -----.---
l
·
I
I
I
i
I
**-DRIVEWAYS AND DRIVEWAY STORM PIPES WILL BE INSTALLED AT THE T1ME OF FINAL RESIDENTIAL BUILD OUT,
--
PLAN VIEW
STATION 0+00 TO 12+00
-=====-~~===:::=:t~~~~~-~~~)
=~~::::l~~l~~l======t::====::±==:===~~~~==E======±=~~~~l;;:=;::~~===:j~
E~ISTING -SEAWALL~
·
EXISTING SEAWALL _ J
MEAN HIGH WATER
·
77'
-
··
I
8'x16'
WATER~
MEAN HIGH
I
I
-
-~--=-----+-+-+----- '
L_I
-r-- - - - - i
---.
I
I
13 _JJI ~ :
1
-
65'
W ·
·
I
1
I
I
---
7.s·
1--:
ao·2 · .
,,_ ____ i;~
I
20'
SEAWALL
BY OTHERS\
- TYP
,
I
,
f l - - - - -1
I
11
I
I I'I:
:
11
64' I
65'
SEAWALL
BY OTHERS\
' ----- L~I---- - - - 1- 1- - - -
---~JI [TY~ ---- ~
!;(.
DOCK
OTHERS~
!--.. (TYP) "
I "'I
1 ~1 1
12
l )R
I
L
I
~
I
,_
+ + I
---
I
:~ :
10
:I - :I
I
1
I
I
-
1
I
I
_
I
_ _ _ "-->-1·~1_.::_ _ _
~
-11 [I - =~
-
w'
-
1 ~1 :
g
:
I
__ '
65'
10'
64'
I
65'
63'
I
65'
I I1
63'
65
:~ :
·
:
62'
DRAINAGE
!
!
I
I
L-- .---~--h
,f------_J
-
-,
65
62'
I
-
~
!
65
I
I
I
80'
(
80'
I
BO'
I
80'
80'
I
I
I
µ
, ---:
-
!
L______ u L______
L____
80'
80'
I
,-----
: ~:
62'
I
I
- i- ~ i --==----=---
·
- -t - - - - - - - - - - -==-- - - - - - ~~ ~~~~~~~~
- - ~~~~ ~~ - - - - - ~ - -r-. - - - - - fl
I
I
6
TYP
,
_
i
5
65
·
61'
I
I
I
I
: :
.I
4
!I I!
65
-f------_J
!
·
-
-
OTHERS~
ENO SEAWAL'::\
_llYP.)_
1
-:-:=___-
-b-1
I,
--
1 ---
.
80
!
·8 ·
!
u
____
----n
I
I
L __
:1:
2
i
85
,!,}
11 51 '
I
80'
I
:~ :
L______ u11u ___ ___ J
i
\ \
69'
_J
-+-+
1 _,1_
\
I
.
- :
:
--_ - ...=-=:s:: 1__
~ =-----I/,
l _..i: ~.,.-------- - - -11 f- ----- ~-
I
---- '
lii l
11
I
I
I
WATER~
DOCK
BY
EX. TOE OF
I SLOPIE \ \
I
, ____
!
·
EX. TOP OF BANK
=------.:::-- '
1-
:~ :
7
I
I
:
1
-1--
w.15·
DOCK
OTHERS
~
(TYP)
I
l~i--+c- -~
8
B
I
~ ~_--___
I
I I:
lJ
lJ
lJ
[E~~,~~~~-L______ : L______ :11L______ u
I
MEAN HIGH
s·.15'
H -
II
.,.
TARPON CANAL
PROPERTY LINE \
-
MEAN HIGH WATER
I
62'
I
I
75
. ' -I
--+
I
TYP_J
:
I,
62'
'
1
[,I_ I1
96
1
I I
:/
·
I/
)
10'
62'
~ DRAI NAGE
_J1 1 ~ E~;~,~~~~---==-=---~/
i - 1 - - - ---__J_-~=
BJ'
100'
-f-=-WlL _
-==- -== - - -
=--=-- =- =-
·
1 ~ 1:
--- -
-
-
I
=1
105· -
--
~<
- C- -
\_PROPOSED
-==-- 13+00 - - --==
1·
-:::::::=- ~-==-- - 1-6+_0_0 ,-1+00
--==- - - - - IB-=+
- (0I- - /--=- ~---=-- "-+-00
~ ----===--'----=
RIP-RAP
~~~~~'=~~~~f=~~~~IJ::~2::,,~::,,,::::;:,,:~=-===1=:==t4'--1\'LlJ:l:=========t=
. ===.::-:::;'~~2'l'~-=-=======ic=-=:.::,,:;;;~:J.j~:?g;l==~~~~~~~~~~~
- 2:=~j;:====::::::r:=
. ~:::::===:::::~~-:i,::~,,:::::::l:::::~:::::::,,:::::;==~~-~;:.::::,;_/~.~t=
.=====-==-=~~:"==-=~~==i:i~i======~j:i?'·~~-==::....::::ot--'~--l~=:::~t:11'~----2-21~50
.
·
·
·
±16'
DRIVEWAY STORM PPE (TYP)l--'
·
·
·
EX. TOE OF" SLOPE__J/
±15' .
"
"
----~
12+00--==- --==----==----==-
1
12' DRAINAGE EASEMENT TYPICAL -
·
1
12' DRAINAGE EASEMENT TYPICAL -
EX. TOP OF BANK_/
50' RIGHT OF WA Y
VASCQ STREET'
DRIVEWAY STORM PIPE
(TYP)
I-
12' DRAINAGE EASEMENT TYPICAL -
-~ ----- - --~- - - - - - - -~- - - - - - _f_ ~--- - - - - - - ~-------- ~---- - ----~ - - - - - - --~ - - --~'- - - -~- - - - - - - - - - - - - - - - - -, ---,-5~NGR-E-SS_/_EG_R-ES-S
'- 30" RIGHT OF WAY
EA-SE_M_E-NT_ FO_R LOT- ,_+-__,
··
I
-
\.
/(
'--!I
I
EXISTIN-G PAVER DRIVE
**
DRIVEWAYS ANO DRIVEWAY STORM PIPES WILL BE INSTALLED AT THE T1ME OF FINAL RESIDENTIAL BUILD OUT,
PLAN VIEW
STATION 12+00 TO 22+50
PREPARED FOR:
BANKS
ENGINEERING
VASCO PGF DEVELOPMENT, LLC
79 14 NORTH SHADE LAND AVENUE, SUITE 200
IND IANAPOLIS , IN 46 250
PHONE' { 3 17) 509-1 368
NO.
DAIT
REV1SION DESCRIPTION
BY
Professional Eng ineers, Planners, & Land Surveyors
Serving The State Of Florida
SITE DEVELOPMENT PLAN
4161 TAMIAM I TRAIL - BLDG 5 UNIT 501
PORT CHARLOTTE, FLORIDA 33952
PHONE: (941) 625-1 165 FAX: (941) 625-1149
VASCO STREET
ENGINEERING LICENSE If EB 6469
SURVEY LICENSE If LB 6690
CHARLOTTE COUNTY , FLORIDA
WWW.BANKSENG.COM
RONALD M. HAY, JR. , P.E.
FLORIDA LICENSE #69163
DATE
PROJECT
5 -1-20 1 6
4 065
DRAWI NG
SDP
DESIG N
DRAWN
CHEC KED
SCALE
SHEET
RJE
RJE
RMH
1"=40'
4
>
ITT
80'
40'
120'
..............................
=-.....
=-.,,,,,.;
GRAPH IC SCALE
40 '
0
1"~
I
14 LF 24" ADS PIPE
INVERT ELEVATION
(-)0.10' NAVO. BB
t
I
I
14 LF 24" ADS PiPE
INVERT ELEVATION
TARPON CANAL
(-)0.10' NAVO 88
CONTROL
81 LF t 8" ADS PIPE
72 LF X 4' WIDE
EXFIL TR ATlON TRENCH
93· LF 18" ADS PIP
'-ADS INLET 86 Lf· X
WIDE:
EXFILTRATION
( TYP)
TRENCH
4'
\_100 LF 18" ADS P!PE
86 LF X 4' WIDE
EXFILTR ATl ON TRENCH
TRACT "A"
'24
(TYP)
~IPE
54 LF 18" ADS PIPE
38 LF X 4' WIDE
EXFILTRATlON TRENCH
21
SUB-BASIN
72 LF X 4 ' WIDE
EXFIL TRATION TRENCH
81 LF 18·H ADS PIPE
35 LF X 4' WIDE
EXFILTRAT10N TRENCH
20
54 LF 18" ADS PIPE
40 LF X 4' WIDE
EXFILTRATION TRENCH
18
19·25
I
99 LF 18" ADS PIPE
1
40 LF X 10 WIDE
EXFI LTR ATl ON
TRENCH
30 LF X 10' WIDE\
EXFI LTR ATl ON
TRENCH
30 LF X 10' WID E \
EXFI LTR ATION
TRENCH
28 LF X 10' WIDE
EXFILTRA Tl ON
TRENCH
( 1 0 LF X 1D' WIDE
15
16
ADS INLET
(TYP)
v
14
I
I
88 LF 18" ADS PIPE
28 LF X 10' WIDE
EXFIL TRA TION
TRENCH
10 LF X 10' WIDE
EXFIL TRATION
TRENCH
13-19
EXFIL TRATION
TRENCH
E
(TYP)
SUB-BASIN
28 LF X 10 ' WIDE
EXFIL TRATION
TRENCH
I
I
ADS INLET
r1D LF X 1D' WIDE
EXFIL TRATION
TRENCH
OS INLET
23 Lf' 18° ADS PIPE__/
9 LF X 4' WIDE
EXFIL.TRATlON TRENCH
17
90 LF 18'' ADS PIPE
22
23
50 LF X 10' WI DE
EXFI LTR ATl ON
TRENCH
ADS INLET
L
' - 74 LF 18" ADS
\_24 LF' 18" ADS PIPE
9 LF X 4' WIDE
EXF]LTRATlON TRENCH
STRUCTURE'
80 LF 1B.. ADS PIPE
72 LF X 4' WIDE
EXFILTRATION TRENCH
80 lF 18" ADS PIPE
EXISTING FlL TER MARSH
\__80 LF 18" ADS PIPE
72 LF X 4' WIDE
EXFIL TRATION TRENCH
80 LF 18~ ADS PIPE
35 LF X 4' WIDE
EXFIL TRA TION TRENCH
BO LF 18" ADS PIPE
51 LF X 4' WIDE
EXFIL TRA TION TRENCH
WATER
SEAWALL BY OTHERS
WATER
80 LF 18" ADS PIPE
CONTROL
66 LF X 4' WIDE
STRUCTURE EXFIL TRATION TRENCH
(
(TYP)
10 LF X 10' WIDE
EXFIL TRATION
TRENCH
28 Lf' X 1Q' WIDE
EXFIL TRAJION
TRENCH
(
I
0+00
I
I
RIO VILLA SUBDIVISION OF BLOCK "B"
(PLAT BOOK 4, PAGE 51)
I
I
I
PLAN VIEW
STATION o+oo TO 12+00
I
I
I
I
TARPON CANAL
14 LF 24" ADS PIPE
INVERT ELEVAT10N
(-)0.10' NAVO 88
54 LF 18" ADS PIPE
40 LF X 4' WIDE
EXFIL TRATION TRENCH
BO LF 18" ADS PiPE
72 LF X 4' WIDE
EXFIL TRA TlON TRENCH
80 LF 18" ADS PIPE
72 LF X 4 ' WIDE
EXFIL TRATION TRENCH
14 LF 24~ ADS PIPE
INVERT ELEVATION
- 0.10' NAVO 88
2J LF 18" ADS PIPE
9 Lf .X 4' WIDE
EXFILTRATION TRENCH
SEAWALL BY OTHERS
WATER
CONTROL
STRUCTURE
8D LF 18" ADS PIPE
72 LF X 4' WIDE
EXFILTRATION TRENCH
80 LF 1'8" ADS PIPE
64 LF X 4' WIDE
EXFIL TRA TlON TRENCH
80 LF 18" ADS PIPE
52. lF X 4' WIDE
EXFIL TRATION TRENCH
80 LF 18" ADS PIPE:
72 LF X. 4' WIDE
80 LF 18" ADS PIPE
72 LF X 4' WIDE
EXFILTRATION TRENCH
EXFI LTRATIDN TRENCH
WATER
CONTROL
STRUCTURE
100 LF 18" ADS PIPE
92 LF X 4' WIDE
EXFILTRATION TRENCH
1 115
12
11
· 87
'28 LF X 1.0' WIDE
EXFILTR ATlON
TRENCH
10 LF X ·10· WIDE
EXFIL TRATION
'TRENCH
I
lF ·f a"
ADS PIPE
28 LF X 1.0' WIDE
EXFIL TR ATlON
TRENCH
10 LF X 10' WIDE'
EXFlL TRAT10N
TRENCH
23 LF 1Bn ADS PIPE /
9 LF X 4' WIDE ::__/
EXFIL TR ATlON TRENCH
ADS INLET
6
86 LF '18" ADS PIPE
28 LF X 1.0' WiDE
EXFIL TR ATl ON
TRENCH
10 LF X 10' WIDE
EXF1LTRAT10N
TRENCH
7-13
ADS" INLET
(TYP)
28 LF X 10' WiDE
EXFIL TR ATlON
TRENCH
10 LF X 10' WIDE
EXF1LTRAT10N
TRENCH
I
I
5
27 LF X 10' WIDE
EXFIL TR ATlON
TRENCH
10 LF X 10' WIDE
EXF1L TRAT10N
TRENCH
8D LF 18~ ADS PIPE
13+00
16+00
27 LF X 10' WIDE
EXFIL TR ATlON
TRENCH
10 LF X 10' WIDE
EXF1L TRAT10N
TRENCH
4
57 LF 18" ADS PIPE
40 LF X 4' WIDE
EXFIL TRA TlON TRENCH
84 LF 18" ADS PIPE
27 LF X 10' WIDE
EXFIL TR ATlON
TRENCH
10 LF X -10· WIDE
EXFIL TRAT10N
TRENCH
80 LF
1 8~
ADS INLET
(TYP)
2
(TYP)
1
85 LF 18" ADS PIPE
3
SUB-BASIN
84 LF 18" ADS PIPE
1-7
ADS INLET
(TYP)
80 LF 18N ADS PIPE
80 LF 18" ADS PIPE
12+00
8
10
SUB-BASIN
ADS INLET
80 LF 18" ADS PIPE_/
g (TYP)
LF 18" ADS PIPE
32 LF X 1D' WIDE
EXFIL TRATION
TRENCH
10 LF X 10' WIDE
f--- +-- ---B?F.JHRATION
TRENCH
[_
~---...~~~-!-...!.-~~
100 LF
ADS PIPE
18 ~
ADS PIPE
17+00
22+50
VASCO STREET
I
I
DRAINAGE NOTES:
RIO VILLA
(PLA T BOOK 3, PAGE 3)
I
1.
ALL EXISTING AND PROPOSED ELEVATIONS REFERENCE THE NAVO 88
DATUM ,
2.
SHOP DRAWINGS ARE REQUIRED FOR ALL. STRUCTURES.
J.
ALL DRIVEWAY PIPES ARE TO BE SIZED BY CHARLOTTE COUNTY ROW
DEPT; AND INSTALLED AT llME OF FINAL RESIDENT1AL BUILD OUT,
I
NOTE'
THE DRIVEWAY CULVERT SIZE, SU MP, &
MA TERIAL ARE SUBJECT TO CHANGE AS A
FUNCTION OF DESIGN REQUIREMENTS,
FUTURE DRAINAGE PROJECTS OR FIELD
·CONDIT10NS AS DETERMINED BY CHARLOTTE
COUNTY RIGHT OF WAY DEPARTMENT AT
THE TIME OF LINE & GRADE INSPECTIONS.
PLAN VIEW
STATION 12+00 TO 22+50
I
i
4.
5.
!
I
"
6.
ALL PIPE USED WITHIN PROJECT TO BE ADS' OR APPROVED
EQU IVALENT.
SPECIFICATIONS FOR ALL ADS INLETS:
RIM = : 3.BD'
18" ADS INVERT($) = ·1.27'_
SHOP DRAWINGS REQU IRED FOR ALL. INLETS.
SEE DETAIL SHEET FOR ADDI TIONAL STRUCTURE AND EXFILTRATION
TRENCH INFORMATION ,
PREPARED FOR:
BANKS
VASCO PGF DEVELOPMENT, LLC
79 14 NORT H S HADELAND AVENUE, SUITE 200
ENGINEERING
!NDIANAPOLIS , IN 46250
PHON E: (317) 509 -1368
NO.
DATE
RE\r1SION DESCRIPTION
BY
Professional Engi n eers 1 Pla n ners, & Land Surveyors
Serving The State Of Florida
STORMWATER MANAGEMENT PLAN
4161 TAMIAM I TRAIL -
BLDG 5 UNIT 501
PORT CHARLOTTE, FLORIDA 33952
PHONE: (941) 625-1 165 FAX: (941) 625-1149
VASCO STREET
ENGll)IEERING LICENSE /l EB 6469
SURVEY LICENSE # LB 6690
CHARLOTTE COUNTY , FLORIDA
WWW.BANKSENG.COM
RONALD M. HAY, JR. , P.E..
FLORIDA LICENSE #69~ 63
DATE
PROJECT
DRAW ING
DESIGN
DRAWN
CHECKED
SCALE
S HEET
5-1-20 16
4065
~SWM
RJE
RJE
RMH
1 "=40'
5
~
>
ITT
80 '
40'
120'
..............................
=-.....
=-.,,,,,.;
GRAPH IC SCALE
40 '
0
1"~
I
-
'
., __
·5'0"')
~
·
--
·-
EXISTING SEAWALL
MEAN HIGH WATER
-T
""
,.,1 "
78'
77'
I
I
·.,
I
E~ISTING -SEAWALL ·Y MEAN HIGH WATER
,,,,
77 '
TARPON CANAL
PROPERTY LINE\
(TYP)~
,,
Qi)~
B'xlS'
DOCK
MEAN HIGH WATER<\" OTHERS----...._
I
I
I
A MlNIMU M OF 4' CLEARANCE SHALL BE MAINTAINED BETWEEN
FUTURE DR IVEWAY AND EXFILTRATION TRENCH , DR IVEWAY SHALL
NOT CROSS EXFI LTRATION TRENCH .
STATION o+oo TO 12+00
I
I
I
NOTE:
PLAN VIEW
~l~~~I~
I
I
PROPERTY LINE
TARPON CANAL
t
.-
/
SEAWALL;;\
BY OTHERS
"'-
~-
'O
,,co~
WA TER
CON TROLSTRUCTURE
8'x16 '
DOCK
B" OTHERS
BYS~~~:~LS\
_TY20p'
A . . ._
WATER
CONTROLSTRUC1URE
1
MEAN HIGH WATER
8'x16'
DOCK
BY OTHERS
BAN~~
EX. TOP OF
EX. TOE OF SLOPE
69'
END SEAWALL
t.~\
' \'
20
.I
I
£. l !c~~-~~"""~·;
'"'
~~ l::l::-l::l=l~::r:-~n:roi
~":":'.:;i"':~l~JtL~-=~~~GJQ):;: :; .,,,,~~L~jl~_.~
~~&;.;Y"r
T
I
O
l
~
4
.
:'...~-IL...~1'['r~~
!
"
a
!
'
~
t
n
:
>
O
J
·
~
"
~
;
'
:,,,,....,J,,l,..,,Jl::o:::::;~~·~~~·~"~:-::=!-:l:--::!::::--:::::~1~0"D··'~'~~jl:
CIID
-
-
I
I
I ·~N~· .
1 1
rR:fNcH (TYPJ 11
3 w
~~ II II ~ -r:11
~· I
r1
{
<( I
I I '"
1
:2: I 1-- I- 7.S'
I1
I
I
I .(,60
4.60 I I
I
i
-----">):\)
I
',
-
4.20
I
I
1 1~
"'°-'' ''1 " ~A~~ .,.Rli~l~~iiJ~l'lM!!..J=Jxwww=
·80~ii!i~~AD~S~IN~:a~ET
~~!!!~~II~l '-"'.J''~'~i~!!~;;""'"3'1:,a:ll ~"~'~=~·~gt~·_::::~-~=-ti ~~ICMU~'="'~~-~~~~~ ~I~~I LlJ!!U~':"~~~-~~~~Ll>
11 11
<§>
: I
<§>
I I
<§>
I
<§>
Il l 1 1
<§>
I I
I :TRENCH (TYP~
11
~:~~J6-1''°
-1
:r EASEMENT
~~t;,------'=-@~t;-'
1 '[I
I
I I
3
I
I ~
i
1I TYPIC~~
11
I EXFIL'TRATION
'C4.60 I
-
II
I
II
I 4.60 I
II
i
I
4.60 I\
II
111
I1 I1
I (TYP)
ADS PIPE
4.60 '
I
I
!
4.60
I
I
II
!
I
II
4.60
' ·'
II
11
t..'.1'0
I
1'
4 50
I
II
4.60
1 I 11 EXFILTRA TION ,.
II
~
4.60 I
~ 7.5'
TYP - iI
I 'C.)'0
10'
4.6:_
ADS PIPE ~
I
--i
.I ~:;i~~~~
TYPICAL
1 1LE~~~~1111~
1~lLE~~· ~~~~~H~L~T~~l~l
----~
-'.-~,
. ,~~~~.~~
~
ll~
I
EE~L
~
~L
__·_o~~~~N~~)E~~~
~~~~.;.~~~3111~~1·1
~
~1·e1L~-----~J
~~-LE~~~·i~~·11111
·-~l'i.!ILIllE __ __-_-~f_E_NC-H-(T_YP_)~L---~~E-T-~
J -~ --~-~~==~-~=(=n-~~~-~-'P ';~
~
~'
I~ ' ~:
Ill
....
:
~ Ill
·Ill
";~";-'
-E 4"
-
L
-!io -,~~i.\J
12
------·-
< uo
-
l_gQ)
~w;+;
" :l ~
--~- -
-,-i === l=E=4":·:_=.=---=--==-~~i!" -1,X>
·'J·t. _
J>.'.'c
-
1
!
I
1 ·""
1i
.
ii,"'J
12' DRAINAGE EASEMENT_IYPICAL -
±l6'
---f
:;;'.\
-
-
-
--~i c - -
-
-
-
16
i
GID_
llo.9'?.i
_ _- 4'' ·----~----°"·~~~-~.::_-::.::~_e.r:,00
.
1
'
I
.
.-., _k°'
-t-~---------~---1!_, DRAINAGE
"-'·
.,, r..0
.
EASEMEN T
-
-
r<' w
~ ,--- -
H tl::~
EX. ')tiEOF"SLOPE -'" /
EX ......T:&P OF BANK_/
TYPICAL- ---·~ -
-
_
i
Lhl!L
-
-
-
______1.,,9'-'( 4.20
" '.=-
e< w
50' RIGf-jT OF
t
'
w1:~10 VASCO STREET
__
__ -
~~
-
c ·w
-
-
-
_ _E·4"_w _
__ ,
j
.
-
-
.;.)~
__
_
-
-
-
11Y
E4~t-1?e- ~ -- -- ~~
- ~\_£__°"
:
EA~EMENT
-i,
-~ 1-1
'
1r_DRAINAGE
TYPICAL - _
25' INGRESS / EGRESS EASEMENT -
-
- --
PROPOSED
RIP- RAP
_"_"w _ _ _
"J.i.+-· .
. . '),°'
+
.>"-.
~-
_,,.~ ±is'
. _,.i.
.
_ ,_
.2-. -
ffiOl
I
22t50
i.':i
'~'\.:1,.
'l
~~ii,'1.
JO' RIGHT OF WAY
t.·
EXISTING PAVER DRIVE
I
I
RIO VILLA
(PLA T BOOK 3, PAGE 3)
I
I
NOTE:
PLAN VIEW
STATION 12+00 TO 22+50
A MINIMU M OF 4' CLEARANCE SHALL BE. MAINTAINED BETWEEN
FURIRE DR IVEWAY ANO EXFILTRATION TRENCH, DR IVEWAY SHALL
NOT CROSS EXFIL.TRA TION TRENCH .
NOTE:
SEE STOR MWATER MANAGEMENT PLAN FOR STORMWA TER PIPE
NETWORK SIZING, EXFILTRATlON TRENCH AND INLET INFORMATION.
PREPARED FOR:
BANKS
ENGINEERING
NOTE:
THE DR IVEWAY CU LVERT SIZE, SUMP, &
MATERIAL ARE SUBJECT TO CHANGE AS A
FUNCTION OF DESIGN REQUIREMENTS,
FUTURE DRAINAGE PROJECTS OR FIELD
CONDITIONS AS DETERMI NED BY CHARLOTTE
COUNTY RIGHT OF WAY DEPARTMENT AT
THE TIME OF LINE' & GRADE INSPECTIONS.
VASCO PGF DEVELOPMENT, LLC
7914 NORT H SHADELAND AVENUE, SUITE 200
!ND IANAPOLIS , IN 46 250
PHONE: ( 3 17) 509-1368
NO.
DATE
RE\r1SION DESCRIPTION
BY
Professional Engi neers 1 Planners, & Land Surveyors
Servi ng The State Of Florida
PAVING, GRADING & DRAINAGE PLAN
4161 TAM IAM I TRAI L - BLDG 5 UNIT 501
PORT CHARLO TTE, FLORIDA 33952
PHONE: (941) 625-1 165
VASCO STREET
FAX: (941) 625-1149
Ii
CHARLOTTE COUNTY , FLORIDA
ENGll)IEERING LICENSE
EB 6469
SURVEY LICENSE # LB 6690
WWW.BANKSENG.COM
RONALD M. HAY, JR., P.E..
FLORIDA LICENSE #69~ 63
OATE
PROJECT
5-1- 2016
4065
DRAW ING
PGD
DESIGN
DRAWN
CHECKED
SCALE
SHEET
RJE
RJE
RMH
1"=40'
6
~
REAR LOT LINE\
REAR LDT LINE\
5'-5"
4'-4-i-"
k
2~"
... d '
4'-1"
;,,
TARPON CANAL
'
TARPON CANAL
I
I
;,,
;,
,.I-[
B'
YE BOLT
ii sEE
~
INDEX 201
DOCK
k
f!'
PLAN
DOCK
SEAWALL
CAP EL 3.90'
STRAIGHT BARS 2"X
RETICULINE BARS 1i-'X;t"
BANDS 1~"X
APPROX. 'li'EIGHT 180 LBS.
is
I
DRAINAGE~'-...
-
~ 2~
f
PRECAST INLETS IN ACCORDANCE WITH
F.D.O.T. INDEX 1f201.
CL.
#4 BARS
J.c-r-@ 12" CTRS. 3. CONSTRUCTION TO BE IN ACCORDANCE
~·
SIDE LOT LINE
TYP ICAL AREA TO BE SODDED
WITH F.D.O.T. SPECIFICATION SECTION 425.
RECOMMENDED MAXIMUM PIPE SIZE:
3'-1" WALL-24" PIPE
4'-1" WAlL-36" PIPE
SECTION
ALL OTHER DISTURBED AREAS
TO BE HYDRDSEEDED
TYPE "D" INLET DETAIL
Not To Sca le
TYPICAL AREA TO BE SODDED\
FRONT SETBACK'\_
__ J
18"
ADS
\\ADS_
PLATE--.......
I
I
I
I
I
I
IL_
IL _ //DRA
INAGE
EASEMENT
24" I
-----5 50
I
_
01
'
~
I
t
II
II
I
SIDE LOT LINE
:11
MINIMUM
I
FINISHED FLOOR U I D - ll
ELEVATION
I
II
II
I
II
5.5o )
/
~-·---
3.80
I
I
<@>
I
I
I
I
__ J
EXFlLTRATION TRENCH
I
I
I
I
4.60
_ _ ·.....i
4.20
FRONT LOT LINE_/
5 50
WATER CONTROL
STRUCTURE
-
I
+--G:ID
I
5.50
-3.80
---
(
-;:r----;
I
., .f -,
~£..?]]
(
i
L~.,<..../-""'-~~~~-"-""'"""· ,,:.....<""-<...<-~~~~~C,.4..-
ADS I
I
l
SIDE LOT LINE
~~,46pA~µ~~fiA6fifa~Aa~A~~A,.__
18"
I
I
WATER CONTROL
STRUCTURE
(2,500 PSI MINIMUM STRENGTH.)
,-+--·+~=r
,
3. 80
REAR SETBACK
2 . CONCRETE TO BE F.D.O. T. CLASS I OR EQUAL ..
d
I
~
EASEMENT
1. 6" WALL THICKNESS MUST BE USED FOR
GRATE
4.20
I
4.20
- - 1 -+-,,,.fT----------~.....
NOTES:
j
SEAWALL
CAP EL 3.9o'\
4.20
4.60
I
I
I
--- - -~ I ~ IL_
~ I IL _ //DRAINAGE
EASEMENT
-- - - --"--'4""'
. 2"'0""""-,--1--
FRONT LOT LINE_/
PLAN
EXFIL TR ATl ON
TRENCH
GRATE
GRATE EL= 5 O'
GRATE EL
4'-o"
'M:IR INV. :3.90'
"-...._
..... kf/" -..,"'\.
I
INV, =1-27
~
J}
ADS
24"
I./'.". ,
~
I
1
--18'' - - - - - - -
Ts"
1
ADS
BOTTO'-J..:(-1 0.60
=---'--'=-"--;~.:__
~-h
24'
ADS
INV. :(- )0. 10'
WE~R INVQ~
EL.- 3.90
5 O'
I
WEIR INV, :J.90'
4' TYP
+t-.. _
WEIR PLATE
18" ADS~
.
4.0'
WEIR PLATE
VASCO STREET
-
...--18" ADS
INV. =1.27'
ADS
t:!:::::!!F==
INV. -=( - )0.10'
BOTIQM ... 1-l 0.60
. I I RIGHT SIDE I I
, ·c·-1-I+1 -LE-FT~'~~~,:-;-11 -+-6"
3'-1"
6
VASCO STREET
:Ji'.
4'-3"
6"
1/4'' ALUMINUM PLATE
TYPICAL LOT STABILIZATION DETAIL
FINAL BUILD OUT
TYPICAL LOT GRADING DETAIL
NTS
N.TS
NOTES:
NOTES:
1) ALL SEAWALLS ANO DOCKS ARE BY OTHERS.
1) AU ELEVATIONS REFERENCE NAVO 1988 DATUM.
CONTROL STRUCWRE WEIR PLATE DETAIL
TYPE "D" CONTROL STRUCTURE
2) ALL SEAWALLS AND DOCKS ARE BY OTHERS.
N.T.S.
CONTROL STRUCWRE DETAIL (TYPICAL 4 PLACES)
N.T.S.
NYLOPLAST TURF TRAFFIC INSTALLATION
2,500 PSI
CONCRETE
12" - 30" DRAIN BASIN
12" -30" INLI NE DRAIN
8" MIN THICKNESS GUIDELINE
FRAME & GRATE/SOLID COVER
6" TH ICK SUB BASE
(LBR 40 MIN. 98% AASHTO T-160)
TOPSOIL
!8" MIN THICKNESS
TOPSOIL
DRIVEWAY DETAIL
N.T. S.
FILTER MEDIA:
THIS MATERIAL SHALL MEET
PERFORMANCE STANDARDS OF SFWMO.
MINIMUM REQU IREMENTS:
1. WASHED (LESS THAN 1% SILT, CLAY,
ANO ORGAN ICS)
2. UNIFORM ITY COEFFICIENT OF 1.5 OR
GREATER
J. EFFECTIVE GRAIN SIZE OF 0.20- 0.55
MM DIAMETER
4. K = 6.33 FT/HR = 199.92 FT/DAY
REPRESENTATIVE SAMPLE SIEVE ANALYSIS
US SIEVE SIZE
l
i
4
10
20
40
50
100
200
UNIFORMITY COEFFICENT: 2 .6 EFFECTIVE
GRAIN SIZE: 0.20 MM
'·
FILTRATION MEDIA SHALL BE FREE OF
CARBONATE MATERIALS ( IE LIMESTONE AND
SHELL)
.._
..
.__
.
TH IS MATERIAL SHALL BE AS SPECIFIED IN
THE FOOT STANDARD SPECIFICATIONS,
SECTION 901
COURSE AGGREGA TE, ANO
SHALL BE EITHER #6 OR #57.
IF #57 IS USED, IT MUST BE WASHED AND
SCREENED TO REMOVE FINES.
THE AGGREGATE MAY BE STONE, SLAG, OR
CRUSHED GRAVEL.
!
4'-10' (SEE PLAN)
I
"
.;::_,-;::_ '
. - . _«.,.~
NON DEGRADING Fl BER 0 US , - - --1:.,.·,,_:S
:.CEi.L;."EC,;;T:.,.8:._A:.,.C;_;KF"IL;.L;_';,J
FILTER TYPE MATERIAL AS
· · · ·
DIRECTED BY ENGINEER, MIRAFI
~!EA,;
· -G~R-~AV_E~L,_
140N OR APPROVED EQUA L.
'°
2.
PRIOR TO INSTALLATION OF THE FILTER MEDIA, THE PERM ITTEE'S
CONTRAC TOR SHALL SUBMIT A CERTIFIED TEST OF THE MEDIA TO THE
PERMITIEE'S PROFESSIONAL ENGINEER AND THE DISTRICT.
THE TEST SHALL
ADDRESS TI-IE FOLLOWING PARAMETERS: UNIFORMITY COEFFICENT, EFFECTIVE
GRAIN SIZE, SIEVE ANALYSIS. PERCENT SIL TS, CLAYS AND ORGAN IC MA TIER,
AND PERMEABILI TY TESTING (CONS TANT HEAD). IF TESTING INDICATES THE
ACTUAL PERMEABILITY RATE IS LESS TI-JAN THE VALUE SPECIFIED IN THE
PERMITTED DESIGN, A PERMIT MODIFICATION WILL BE REQUIRED TO LENGTHEN
THE EFFLUENT FILTRATION SYSTEM. THE PERMITTEE SHALL ALSO NOTIFY THE
SURFACE WATER REGULATION MANAGER, LEE COUNTY REGULATION
DEPARTMENT, AT LEAS T 48 HOURS PRIOR TO COMMENCEMENT OF
CONSTRUCTlON OF THE EFFLUENT FILTRATION SYSTEM, SO THAT DISTRICT
STAFF MAY OBSERVE THIS CONSTRUCTION ACTIVITY.
6" '---.,,,n'tEL = 2.8'
TOP OF TRENCH/PIPE
18"
MIN
18" ADS UNDERDRAIN'---+-- - - \
12"
OR APPROVED EQUAL,
COURSE GRAVEL
SLOTTED DOWN
] MIN
INVERT EL ~ 0.20'
~~~---............
EL = 1. 27'
PIPE INVERT
SHWT /
EL = 0 . 27'
BOTTOM OF TRENCH
4" MIN ON 12" - 24"
6" MIN ON 30"
~
Tl1E BACKFILL MATERIAL SHALL BE CRUSHED STONE OR OTl-IER
GRANULAR MATERIAL MEETING Tl-IE REQUIREMENTS OF CLASS t
CLASS II. OR CLASS Ill MATERIAL AS DEFINED IN ASTM 02321BEDDING & BACKFlll. FOO SURFACE DRAINAGE INLETS SHALl BE
PLACED & COMPACTED UNIFORt.t.. Y IN ACCORDANCE WITH ASTM 02321 _
4'-10' (SEE PLAN)
1_ GRATES/SOUO COVERS SHALL MEET H-20 LOAD RATING FOR
30 ' PEDESTRIAN & 12" - 30" STANDARD & SOLJD
2_ DESIGN SHOULD ACCOUNT FOR ROOT DEPTH TO AL LOW
TURF TO GR.OW AND PREVENT EROSION AROUND GRATE
SO Tl-IA T HAZARDS 00 NOT FORM_
PREPARED FOR:
BANKS
ENGINEERING
VASCO PGF DEVELOPMENT, LLC
NORT H SHAD ELAND AVENUE, SUITE 200
!NDIANAPOLIS , IN 46250
PHONE: {.317) 509-1 368
Professional Engineers, Pla nners, & Land Surveyors
ND.
DATE
BOTTOM RANGE OF
FRAME MUST BE
SUPPORTED BY
CONCRETE COUAR
TRAFFfC LOADS: CONCRETE: SLAB DIMENSIONS
ARE FOR GUIDELINE PURPOSES ONLY_ ACTUAL
CONCRETE SLAB MUST BE DESIGNED TAKING INTO
CONSIDER-0.TION LOCAL SOIL COND fHONS, TRAFRC
LOADING. & Oll-1ER APPL ICABLE DESIGN FACIDRS_
I,
1. THE CONTRACTOR SHALL FURNISH THE ENGINEER/INSPECTOR Vv'I TH
STORM WATER FIL TRA DON MA TERI AL PERFORMANCE SPECIFICATIONS ON THE.
MEDIA ACTUALLY BEING DELIVERED TO THE PROJECT SITE.
79 1 4
.·
BOTTOM FLANGE OF
FRAME MUST BE
SUPPORTED BY
CONCRETE COLLAR
MINIMUM PIPE BURIAL
DEPTH PER PIPE
MANUFACTURER
RECOMMENDATION
N.T.S
l
.
DRAINAGE EASEMENT
FILTER AGG RE GATE:
EXFIL TRATION TRENCH
I
18" MIN TH ICKNESS
(2)
MIN DEPTH FOR TURF
(2)
REVISION DESCRIPTION
BY
Serving The Stole Of Florido
THIS PRINT DISCLOSES SUBJECT MA TIER IN WHICH
l>/YLOPL'IST f1AS PROPRJETARY RIGHTS_ "IBE RECElf'T
OR POSSESSION OF Tl-!IS PRIITT DOES NOT CONFER.
TRl\NSFER. OR LICENSE Tl-IE USE OF THE DESIGN OR
TEC HNICAL INFORMATION Sl-JOWN HEREIN
REPRODUCTION OF TillS PRINT OR ANY INFORMATION
CONTAINED HEREIN, OR MANUFACTURE OF Afrf
ARTICLE HEREfROM, FOR THE DISCLOSURE TO OTHERS
IS FORBI DDEN, EXCEPT BY SPECIFIC WRITTEN
PERMISSKJN FROO NYLO!'li\SL
,;,,.,, ""-"'AORAWNBY
EBC
DATE
MATERIAL
Nyl~asf
01-05-09
REVISED B¥
Nl.IH
PROJIOCT NOJNAME
3130 VERONA AVE
BUFORD, M.!0518
PHN (770) 93'!-24\J
FAX (770) 9:\l-2490
WWW nylop l.1Sl.US.CDnl
12 IN -30 IN DRAIN BASIN & INLINE DRAtl
TURf TRi\FFIC INSTALLATION
Ol-14-16
C------+----------"---=~====~--OWG SIZE
A
SCALE
1:15
SHIOET
OWG NO_
1 OF 1
7001-110-3411
PAVING GRADING & DRAINAGE DETAILS
4161 TAM IAM I TRAIL - BLDG 5 UNIT 501
PORT CHARLOTTE, FLORIDA 33952
PHONE: (941) 625-1165 FAX: (941) 625-1149
VASCO STREET
ENCINEERING LICENSE fl EB 6469
SURVEY LICENSE # LB 6690
CHARLOTIE COU NTY , FLORIDA
WWW.BANKSENG.COM
RONALD M. HAY, JR., P.E.
FLORIDA LICENSE #69163
DATE
PROJECT
DRAWI NG
DESIGN
DRAWN
CHECKED
SCALE
SHEET
5-1-20 16
4065
PGD- DT
RJE
RJE
RMH
N. T.S .
7
25' f"RONT SETBACK
VASCO STREET RIGHT CF WAY
20' WA l(R SrraACI<
8l.ILOABLE LOT AREA
TARPON CANAL
soo
E~STING
VASCO STRUT
MAINTAIN SILT
FENCE-~
DOJR1NG coosmucnoN
~
-...
{N9-IED FUXJI MINIMUM ELAVATIOO: 8.0' {NAW 88) / 9.1' (NGVll 29)
11
,,.
GRADE AT STIOR,t,iNAGE EASEi.ENT
IO'
DRAINAGE EASEMENT
ST£MWALL
" - . . _ CONSTRUCTION ~
28'-4~'
GRADE AT STRUC1URE
5.5 \NAVO 881 '\
5
.L!"":" . -
1£ DRIVEWAY IBY OTMERS)
VARIES:
VARlES
IO'
~EXISTING SEAWALL
""''
'"''"'·
ACROSS CANAL
OOCKS,
ANCHORS,
-·-
BY OTHERS)
'
MEAN HIGH WATER
-0.10 (NAVO 86)
'"'"
.
r:..~~~'', '"'
..- '·· -::--. '\,
~ .:-.;,
' '"
. '-<
, ,.
PROPOSED
Of\fiCFMENT
GP.A; AT STRUCTURE
I
12'
"
soo
NORTH BRANCH
ALUG.l.TOR CREEK
soo
GRADE AT STRUCTURE
.5.5 tNAW BB, \
5.5 \NAVO 881 '\.
-"'---'---7-_'
£X/Sl/NG CR()(jNf}_
'
6.1
10'
DRAINAGE EASEMENT
,...-MAINTAIN SILT FENCE
'~
~ / SEcx:=~~ cC:STRUCTlON
CONCR / _).//
, ·'
IO'
DRAINAGE EASEMENT
IO'
VARIES
,___,.
3.90 \NAW 88;
±J.4 J_,,---"t.tAlNTAIN SILT FENCE
DURING CONSTRUCTION
~
,,
·_
UEAN HIGH WATER·
-0.lO NA\oO 88
'
'
'· PROJ'OSED RIP-RA
-
'
-. . .
'
.
.·.-. - +'
..
'MOE
- _. ·' EX_~~~~ ·
. '.' (SEE DETAIL SHEED .' -
. -' -
;
SECTION C-C
-
"'
-
. ' ·_
..
-.
5ECTION P-P '
"''
7.5'
7.5'
SIDE SETBACK
SIDE SETBACK
'
;:·
'·
5ECTION E-E
"'
65' BU llD.l.BlE AREA
" ANISHEO fUXlll MINIMUM ELAVATION: B.O' (NA'r
-
I 9.1' (NGl,U 29)
7 5'
.-_ . -
7.5'
SIDE SETBACK
SECTION F-F
'~
PREPARED FOR:
BANKS
ENGINEERING
VASCO PGF DEVELOPMENT, LLC
79 14 NORTH SHAD ELAND AVENUE, SUITE 200
INDIANAPOLIS, IN 46250
PHONE' {317) 509 -1 368
NO.
DAIT
REV1SION DESCRIPTION
BY
Professional Eng ineers, Planners, & Land Surveyors
Serving The State Of Florida
CROSS SECTIONS
4161 TAMIAM I TRAIL - BLDG 5 UNIT 501
PORT CHARLOTTE, FLORIDA 33952
PHONE: (941) 625-1 165 FAX: (941) 625-1149
VASCO STREET
ENGINEERING LICENSE ff EB 6469
SURVEY LICENSE # LB 6690
CHARLOTTE COU NTY , FLORIDA
WWW.BANKSENG.COM
RONALD M. HAY, JR., P.E.
FLORIDA LICENSE #69163
DATE
PROJECT
DRAWI NG
DESIGN
DRAWN
CHECKED
SCALE
SHE ET
5-1-20 16
4065
_XS EC
RJE
RJ E
RMH
N. T.S.
8
-
I
I
INSTALL AND MAINTAI N : \
25 LF OF TU RBIDI TY BARRIER
DUR IN G CONSTRUCTION
11
Il
I
111
~
I
.
I
I
!
-~
~~
_ __..,~-
(~
4.~0 I
I
-
/
I
I
~
I
~-_,\..--=
-~---=-_,,.
;i·~-iij:iiiiiiim;:&iiiiiiii:iiiiiiiii!i:;ii~~·~'T'~;;~~-;_;;;;.ef?'!llillS~iiCil!!i~ill'
I: II
I
4.24D LF OF SILT FENCE
I
1I
11
DURING CONSTRUCTION
i
TRACT "A"
I
I
..,
:
43>
I
24
I
I
~
~
: :
"'
I
I
I
I
:
I
I
I
.
4.60
23
I
I
I
I
I
., .
I
I
I
I
I
I
I
'
4.60
22
I
..
I
LhlQ...J
I
J.
I
I
.,_1'!!!!!!!!!!!1!11~·. ~"'
...
21
43>
4.60
I
I
'
I
I
I
I
I
I
- +--
I
43>
4.60
I
I
I
'
I
I
I
-
' I
II
20
I
(TIO)
r
II I~
I I
I
I
I
I
MAINTAIN-~
DURJNG CONSTRUcnoN
~
4 20
·
~I
~
~
INSTALL AND
25 LF OF 1URBIDITY BARRIER
I
"·~
Iii
Ila®
I
I
I
I
/
CT2lL
-
I
(IT[)
I
I
II ""1I~
I
I
I
19
43>
INSTALL ,A.NO MAINTAIN
4,240 LF OF SILT FENCE
t- DURING CONSTRUCTION
I
·
I
I
I
<@>
J
I
. 4.50 · 1
:
I
I
I
·
I
'
~-:
;a1
I'-"'-'
I
I
I
4.60 · ~
x,
UJi
I
I
I
17
<@>
I
I
I
I
I
(!][:!
-~I ~
lia -
I
I
I
:
- 4.50 :
:
I
I
I
16
~
~
I
I
(];ID
~
81
I
I
I
I
I
I
r
:
:
I
I
I
14
~
4.80
·
I
43>
40'
0
80'
120·
GRAPHIC SCA LE 1"= 40'
I
I
,~,.=,,
~
'·"'
I0 ~
10 GJj
43>
I
~ ~ 1~ ~1.,,,...
;:m;w; · :
I <>
15
I£
I~
I
I
I
4.60 ":
I
I
! '
'
:~- -$I
r
:
0
l -'1r~"'~..
CT10)
!-"-
I
I
I
18
I
I
I
-
I
13
I
~I
_JI
43>
I 1
l)
·~:
460 !
---
I ::2:1
J ~---------J ~-------J L_______ J L_______ J L_______ J L_ _______ J L_______ J L_______ J ~-------J ~-------J ~ ------~ J
80
1'''~'!~Ll.~lllll:=::jEB!l!l~~~7" ' ~ ~§L" ----·~~,:~:,~,~~-!;;;;.~EB!l(J:SO)~·!'!'~---lll~::::::::"l·t~T7""'~~~
4
0
1
i;~---------_gj~!::j!:tt:=:==JfBlll~l!l
l! J!i l~l ~a!l l l 't±~ ~:~t:=:lralUMl'lllti
!
' £~~:!:~,~----j'~~2t
--+-'--+
'
1+ 0
-=.
c::_c::_ - - -
_ - _- ,__-__- ~-_- _-_-::_ __
-~- - _- _ -_- - - _-::_ -_-::_ - _-::_ -_-::_ -~_~-~~-
_
- -
-
_ - __ -=---==--
_
_
_
_
·
·
~~
__ __ __ __ ____ -- -=----==---:::::_ -- ~
AA
+-
______
- -
- -
- -
- -
7+oo -
-
\
~
---- ---- -- - -_-_ ----
- INSTALL
AND MAINTAIN
-- - ____ __ _ _ _ _\____
__DURING
4;240 LFCONSTRUCTIQ!i_
OF SILT FENCE
s+oo
B+oo
l
~
y-
_
___ ___
-ro+oo-
=
-::_-::_ -::_-::_ -::_-::_
rr+oo
12+00
I
I
-
-------~---------~---
------
-
~----
------
- -- - - - - - - - - r - - - --
---
I
I
I
RIO VILLA sJB01v1s10N OF BLOCIK "B"
I
(PLAT BOOK 4, PAGE 5 7)
I
I
PLAN VIEW
STATION 0+00 TO 12+00
I_
LI·
J
-
I
--· -
1-
l
L
l
1-
I
INSTALL AND MAINTAIN
25 LF OF TIJRBIDITY BARR IER
I
I
DURING CONSTRUCTION
4.20
I
4.20
~~Ii
11
12
43>
4.60
I
___i jJ
;;;) !1il(
J.80
I
I
I
I
9
10
43>
4.60
43>
I
'·"
4.60
I
I
8
__
~
_ _ _ _ _J
L
L--~ ----_J
__
~
____
_J
L
_______
4.so
I
L _____ ~ _
_J
7
5
I
I
_j
I
I
4.60
I
I
I
I
4.60
I
L __ _ ____
I
_J
I
I
I
I
I
L _ __ ____ _J
llll- -
·"'
4.20
I
I
I
I
I
I
4
I
I
I
L
-
.:tl
INSTALL AND MAINTAIN
238 LF OF TURBIDITY BARRIER
DURING CONSTRUCTION
INSTALL AND MAINTAIN
4,240 LF OF SILT FENCE
DURING CONSTRUCTION
4.20
I
()I
INSTALL AND MAINTAIN
25 LF OF TURBIDITY BARRIER
DURING CON-STRUCTION
IN STALL ANO MAINTAIN
4,240 LF OF SILT FENCE
DURING CONSTRUCTlON
3
~
G·][wH
~
I
I
L __ _ _____ J
I
I
I
I
I
I
I
4.20
I
I
2
I
I
I
I
I
43>
4.60
L_ ___ ,_ _ _ _ -~-1
1
43>
L--- ~--------
llll- -
~---
~
SILT FLOW
22+50
TYPE 3 SI LT FENCE
I
I
RIO VILLA
OPTIONAL POST POSITJONS ~
· 0 .,
PRINCIPLE POST POSITION
(PLAT BOOK 3, PA GE 3)
I
I
"'~'-' '
'
~
IN.~~- 'F\LTER
PLAN VIEW
FABRIC
"LT FLOW
STATION 12+00 TO 22+50
'viNYI. SHEATHED EAW STEEL CABLE
9800 LBS. BREAKIN G STRENGTH) 'M TH
ALVAN IZED CONNEC TORS (TOOL FREE DISCONNECT)'
~
SLOTTED PVC CONN ECTOR PIPE
{ METAL COLLAR REINFORCED)
.
CLOSED CEU SOLID PL ASTIC FOAM
ROTATION (8" DIA. EQU1v:) (17 LBS.
PER FT. BUOYANCY),)
j
I
(18 OZ. NYLON REINFORCED
PVC FABRIC (300 PSI TEST))
- ~STRESS PLATE
~8
.
GALVANIZED CHAIN
A
c:
OZ. NYLON RE INFORCED
PVC FABRIC (JOO PSI
TEST) 'Ml}! LACIN G )
GROMM ETS
I
0, =5· STD. (SINGLE PANEL FOR DEPTHS 5 ' OR LESS).
D, - 5' sm. (ADDI TIONAL PANEL FOR DEPT HS > 5').
6! MAX .
i'GALVANIZEO CHAIN-
d'
"
~ ·
,
,,,
CURTAIN TO REAC H BO"[TOtd UP TO DEPTH S OF !O FEET.
TW0(2) PANELS TO BE USED fOR DEPTHS GREATER THAN
10 FEtT UNLESS SPECIAL OE:PTH CURTAINS SPEClflCALLY CALLEO
FOR IN niE PLANS OR AS OETERtdlNED BY THE ENGINEER.
NOTICE:
.
POST (OPTIONS:
2" X 4-" OR
2~ MIN . DIA. WOOD;
STEEL
1.3J LBS/fl. MIN .)
'
l,..---:-_i'POLYPRO ROP[
{600 LB . BREAKING
STRENGT}I)
TYPE 1
TYPE 2
SECTION
CLOSED CEU SOI.IQ PLASTI C FOAM
FLOTATION (6" DIA. EQUIV.) (12 LBS,
PER FT BUOYANCY)
--;
POST (OPTIONS: 2"
MIN. DIA. WOOD;
1.33 LBS/FT MIN . )
2-J"
~
0
~
z
COMPONENTS Of TYPES - ANO - - MAY BE SIMILAR OR IDENTICAL
TO PROPRIETARY DESIGNS. ANY INFRI NGEMENT ON THE PROf'RIETARY
RIGHTS OF THE DESIGNER SHALL BE THE SOLE RESPONSIBIUTY OF
11'1E USER. SUBSTITUTIONS F:OR T'l'P[S N ANO -~ SHAU BE AS
APPROVED BY THE ENGINEER .
:;,
·ro
"'
'
r
~
" - ,
<:, I "'
::;
'ro
tj--
~
~
I
0
0
::;
~
4 ~ OR
STEEL
.-ro _ _
" I
w
18 OZ. NYLON REINFORCED
PVC FABRIC (300 PSI TEST)
x
FILTER
6' MAX.
I
~
·
FABRIC (IN
WITH
SEC , 985 FOOT SPEC.)
co NFORMANCE.
,, ' ..
\
ELEVATION
NOTE:
SILT FENCE TO BE PAID FOR UNDER THE CONTRACT UNIT PRICE FOR STAKED SILT FENCE (LF) ,
FLOATING TURBIDITY BARRIER DETAIL
STAKED IURBIDIIY BARRIER DETAIL
!YEE 3 SILT EENCE DETAIL
N.T.S.
N. T.S.
N.T.S.
PREPARED FOR:
NOTE:
INS TALL AND MAINTAIN A TOTAL
OF 4,240 LF OF SILT FENCE AND
A TOTAL OF 338 LF OF TURBID ITY
BARRIER DUR ING CONSTRUC TION
BANKS
ENGINEERING
VASCO PGF DEVELOPMENT, LLC
79 1 4 NORTH S HAD ELAND AVENUE , SUITE 200
INDIANAPOLIS, IN 46250
PHONE' (317) 509-1368
Professional Engi n eers, Planners, & Land Surveyors
NO.
DAIT
RE\11SION DESCRIPTION
BY
Serving The Slate Of Florida
BEST MANAGMENT PRACTICES PLAN & DETAILS
4161 TAM IAM I TRAIL PORT
BLDG 5 UNIT 501
VASCO STREET
CHARLOTTE, FLORIDA 33952
PHONE: (941) 625-1 165
FAX: (941) 625-1149
CHARLOTTE COU NTY , FLORIDA
ENGINEERING LICENSE fl EB 6469
SURVEY LICENSE
#
LB 6690
WWW.B ANKSENG.COM
RONALD M. HAY, JR., P.E.
FLORIDA LICENSE #69163
DATE
PROJECT
5-1 -2016
4065
DRAWING
BMP
DES I G~
DRAWN
CHEC KED
SCALE
SHEET
RJE
RJE
RMH
1 "=40 '
9
'El REAR SElBACK
TARPC»l CANAL
4'
TARPON CMIAL
4'
SEAWALL CAP
5.5.'.l NAVO 88
ooac
(SEAWAU..
OOCKS,
ANCH~S.
TDP ()"BANK
BYOlliERS)
l.66
NA'Al 88
. ~. . , . : 1.. .,
. : ·.
.... ·...
:.
- :· ··.~ ... ,.·:..
·. '....·....... '.
I
"-WEAN LOW WAlER
..
:
::
- 1.34 NAW 88)
··,
SECTION A-A .; · .:
NTS
SECTION 8-8
· .. ..
· :
... .~
· ·· ·
~
·
· t
!:. · : . .
·
.
:
,. ·. · , · .... ·.
""":\'
·;
~
'
.. .
; .:
:.
':.
TA!f'OH CANAL
RtAR SElBACK
.. :
HTS
~
·:
2ff
.
;
~:
·"...:
SECTION C-C
NIS
.".,
-
:
VASCO STREET
CROSS SECTIONS
16-016 I OC1'QBD. 18, 2016