You can copy from here when filling out the rest of the page.
Miami-Dade County. HSH Willisle Marina Company. Boca Raton, Florida.
PROJECT PURPOSE:
Basic: The basic project purpose is to improve vessel access.
Overall: The overall project purpose is to improve vessel access within Williams Island, City of Aventura, Miami-Dade County, Florida.
TO WHOM IT MAY CONCERN: The Jacksonville District of the U.S. Army Corps of Engineers (Corps) has received an application for a Department of the Army permit pursuant to Section 10 of the Rivers and Harbors Act of 1899 (33 U.S.C. §403) as described below:
APPLICANT: HSH Willisle Marina Company, LLP
c/o Scott Huizenga
7900 Glades Road, Suite 402
Boca Raton, FL 33434
WATERWAY AND LOCATION: The project would affect waters of the United States associated with Maule Lake, to the west of Dumfoundling Bay. The project is located within Williams Island at 4100 Island Boulevard, in Section 10, Township 52 south, Range 42 east, City of Aventura, Miami-Dade County, Florida (Folio Number 28-2210-066-0023).
Directions to the site are as follows: From I-95 north, exit on Ives Dairy Road (NE 203street). Turn right onto Ives Dairy Road, bear right onto US-1 (Biscayne Boulevard), and turn left onto NE 183rd street (Williams Island Boulevard).
APPROXIMATE CENTRAL COORDINATES:
Latitude:25.941111°
Longitude: -80.136111°
PROJECT PURPOSE:
Basic: The basic project purpose is to improve vessel access.
Overall: The overall project purpose is to improve vessel access within Williams Island, City of Aventura, Miami-Dade County, Florida.
EXISTING CONDITIONS: The upland areas adjacent to the project sites consist of a multifamily residential development and associated recreational and parking areas. The work areas are located within the Williams Island Marina, a partially-enclosed basin with the perimeter of the basin supporting mangrove trees.
A site inspection performed by Coastal Systems International on November 3, 2017 indicates that water depths within the survey area ranged from approximately 4 to 16 feet deep, with the deepest water occurring at the north portion of the survey area in the center of the slip footprints. The submerged lands within the survey area consisted mostly of sand with high concentrations of silt and organic material, dense aggregations of oyster shells, sporadic man-made debris, various upland vegetative debris primarily from Red Mangrove (Rhizophora mangle) leaves in the area near the floating dock and Australian Pine (Casuarina equisetifolia) west of the floating dock. Based on site observations during the survey, the top 6 feet of water in the survey area was made up of primarily freshwater. Visibility within the marina was generally very good (approximately 10 feet) in the freshwater layer as there was little suspended sediment in the water column and the tannin levels in the water were moderate.
At a depth of 6 feet, a very prominent hydrogen sulfide rich layer was apparent, likely due to a combination of the decayed organic material and the lack of water circulation. Below the hydrogen sulfide rich layer, saltwater was present but light levels were drastically reduced. Within the salt water layer (from 6 feet below the surface to the bottom) the visibility was generally low (less than 3 feet) due to a combination of the easily suspended sediment in the water column, the effects of hydrogen sulfide rich layer separating the freshwater and saltwater, and the reduced light levels due to the tannins in the freshwater layer above.
No seagrass, macroalgae, sponge, or coral species were observed colonizing the surface of the existing floating dock or growing on the substrate within the Project area. Commonly observed fish species within the Project area included the primarily freshwater Mosquitofish (Gambusia affinis) which gathered in schools around the floating dock from the surface down to a depth of approximately 4 feet. Just below the freshwater layer, juvenile Gray Snapper (Lutjanus griseus), juvenile Great Barracuda (Sphyraena barracuda), and assorted Blenny species were observed. No fish species were observed in or below the hydrogen sulfide rich water layer, from 6 feet below the surface to the bottom.
PROPOSED WORK: The applicant seeks authorization for (1) the replacement of floating docks in the same footprint; (2) installation of finger piers; (3) reallocation of 106 powerboat slips based on actual usage patterns as follows:
North Marina:
Four existing 66-foot long slips will be converted into two 130-foot long slips. No additional structures to be installed in this area.
North Lagoon Marina 1:
Replacement of a 7.6 foot wide by 338.3 foot long floating dock (2,576.3 square feet) and installation of eight 5.9 foot wide by 29 foot long (171.1 square feet each) finger piers and one 11.1 foot wide by 29 foot long (321.9) finger pier. The finger piers will be secured by 15 wood piles and will be connected to the uplands by an aluminum gangway.
North Lagoon Marina 2:
Four existing 53-foot long slips will be converted into three 87-foot long slips. No additional structures to be installed in this area.
Island Club Marina:
Northwest Corner: Two existing 70-foot long slips will be converted into one 130-foot long slip. No additional structures to be installed in this area.
Southeast Corner: Two 20-foot long slips will be created. No additional structures to be installed in this area.
West Marina:
Ten existing 76-foot long slips will be converted into three 136-foot long slips and three 117-foot long slips. No additional structures to be installed in this area.
Temporary turbidity curtains will be deployed and remain in place for the duration of all in-water activities in/over waters of the United States. The work is proposed in accordance with the attached site plans.
AVOIDANCE AND MINIMIZATION INFORMATION – The applicant has provided the following information in support of efforts to avoid and/or minimize impacts to the aquatic environment:
“Turbidity curtains will be installed during the replacement of the pilings in North Lagoon Marina 1. All watercraft associated with the construction of the proposed floating dock will only operate within waters of sufficient depth to preclude damage to the submerged lands and resources; sufficient depth can be defined as one-foot of clearance from the deepest draft of the vessel to the top of any submerged resources. Please note that this is the only proposed construction for this permit application.
The shoreline adjacent to the area where the proposed floating dock will be replaced also supports mangroves. Please note that the mangrove trees along the shoreline of the North Lagoon Marina 1 will not be impacted, as construction will occur from a barge. In addition, no mangrove tree trimming is proposed.”
COMPENSATORY MITIGATION – The applicant has offered the following compensatory mitigation plan to offset unavoidable functional loss to the aquatic environment:
“No dredging activities are proposed as part of this permit application. The mangrove trees along the shoreline of the North Lagoon Marina 1 will not be impacted, as construction will occur from a barge. No mangrove tree trimming is proposed as part of this Project’s scope; the mangrove trees have subsisted along the Williams Island North Lagoon Marina shoreline since at least 1987, and there are no plans to eradicate the healthy trees. No shoreline construction is being proposed. ”
CULTURAL RESOURCES: The Corps has determined the permit area activity is of such limited scope there is little likelihood of impact upon a historic property; therefore, the proposed project would have “No Potential to Cause Effect”.
By copy of this public notice, the Corps is providing information for review. Our final determination relative to historic resource impacts is subject to review by and coordination with the State Historic Preservation Officer.
ENDANGERED SPECIES: The U.S. Army Corps of Engineers (Corps) has determined the project may affect the West Indian manatee (Trichechus manatus), American Crocodile (Crocodylus acutus), green sea turtles (Chelonia mydas), loggerhead sea turtles (Caretta caretta) and designated critical habitat, hawksbill sea turtles (Eretmochelys imbricata), Kemp’s ridley sea turtles (Lepidochelys kempii), leatherback sea turtles (Dermochelys coriacea), smalltooth sawfish (Pristis pectinata), Nassau Grouper (Epinephelus striatus).
The Corps has determined that the proposed project would cause the following effects on federally listed species:
West Indian Manatee: Potential impacts were evaluated using the Corps of Engineers, Jacksonville District, and the State of Florida Effect Determination Key for the Manatee in Florida (Manatee Key) dated April 12, 2013. Use of the Manatee Key resulted in the following sequential determination: A > B> C > G > H > I > J > K > “May Affect”. The project site is not located in a warm water aggregation area; however, the project has not been reviewed by the Florida Fish and Wildlife Conservation Commission or the U.S. Fish and Wildlife Service (FWS) and confirmed consistency with the Miami-Dade County Manatee Protection Plan has not been provided. Therefore, formal consultation with the FWS is required.
Swimming Sea Turtles and Smalltooth Sawfish: The Corps has determined the proposed project “may affect, but is not likely to adversely affect” green sea turtles, loggerhead sea turtles, hawksbill sea turtles, Kemp’s ridley sea turtles, leatherback sea turtles, and smalltooth sawfish. The Corps evaluated the proposed work utilizing NMFS’s Statewide Programmatic Biological Opinion (SWPBO) dated December 4, 2015 and has initiated the Tier II process established in the SWPBO reviews.
A “no effect” determination was reached on the American Crocodile. Consultation with Service Agencies is not required for determination of “no effect
The Corps has determined the proposal will not affect any other threatened or endangered species or designated critical habitat other that the species listed above.
ESSENTIAL FISH HABITAT (EFH): This notice initiates consultation with the National Marine Fisheries Service on EFH as required by the Magnuson-Stevens Fishery Conservation and Management Act 1996. The proposal would impact approximately
4,188 square feet of submerged bottom utilized by various life stages of marine species. Our initial determination is that the proposed action would not have an adverse impact on EFH or Federally managed fisheries. Our final determination relative to project impacts and the need for mitigation measures is subject to review by and coordination with the National Marine Fisheries Service.
NOTE: This public notice is being issued based on information furnished by the applicant. This information has not been verified or evaluated to ensure compliance with laws and regulation governing the regulatory program. The jurisdictional line has not been verified by Corps personnel.
AUTHORIZATION FROM OTHER AGENCIES: A Water Quality Certification may be required from the Florida Department of Environmental Protection and/or one of the state Water Management Districts.
COMMENTS regarding the potential authorization of the work proposed should be submitted in writing to the attention of the District Engineer through the Miami Permits Section, 9900 Southwest 107the Avenue, Suite 203, Miami, Florida 33176 within 21 days from the date of this notice.
The decision whether to issue or deny this permit application will be based on the information received from this public notice and the evaluation of the probable impact to the associated wetlands. This is based on an analysis of the applicant's avoidance and minimization efforts for the project, as well as the compensatory mitigation proposed.
QUESTIONS concerning this application should be directed to the project manager, Nicole Fresard, in writing at the Miami Permits Section, 9900 Southwest, Suite 203, Miami, Florida 33176; by electronic mail at Nicole.D.Fresard@usace.army.mil; by facsimile transmission at (305) 526-7184; or, by telephone at (305) 779-6053.
IMPACT ON NATURAL RESOURCES: Coordination with U.S. Fish and Wildlife Service, Environmental Protection Agency (EPA), the National Marine Fisheries Services, and other Federal, State, and local agencies, environmental groups, and concerned citizens generally yields pertinent environmental information that is instrumental in determining the impact the proposed action will have on the natural resources of the area.
EVALUATION: The decision whether to issue a permit will be based on an evaluation of the probable impact including cumulative impacts of the proposed activity on the public interest. That decision will reflect the national concern for both protection and utilization of important resources. The benefits, which reasonably may be expected to accrue from the proposal, must be balanced against its reasonably foreseeable detriments. All factors which may be relevant to the proposal will be considered including cumulative impacts thereof; among these are conservation, economics, esthetics, general environmental concerns, wetlands, historical properties, fish and wildlife values, flood hazards, floodplain values, land use, navigation, shoreline erosion and accretion, recreation, water supply and conservation, water quality, energy needs, safety, food, and fiber production, mineral needs, considerations of property ownership, and in general, the needs and welfare of the people. Evaluation of the impact of the activity on the public interest will also include application of the guidelines promulgated by the Administrator, EPA, under authority of Section 404(b) of the Clean Water Act or the criteria established under authority of Section 102(a) of the Marine Protection Research and Sanctuaries Act of 1972. A permit will be granted unless its issuance is found to be contrary to the public interest.
The US Army Corps of Engineers (Corps) is soliciting comments from the public; Federal, State, and local agencies and officials; Indian Tribes; and other Interested parties in order to consider and evaluate the impacts of this proposed activity. Any comments received will be considered by the Corps to determine whether to issue, modify, condition, or deny a permit for this proposal. To make this determination, comments are used to assess impacts to endangered species, historic properties, water quality, general environmental effects, and the other public interest factors listed above. Comments are also used to determine the need for a public hearing and to determine the overall public interest of the proposed activity.
COASTAL ZONE MANAGEMENT CONSISTENCY: In Florida, the State approval constitutes compliance with the approved Coastal Zone Management Plan. In Puerto Rico, a Coastal Zone Management Consistency Concurrence is required from the Puerto Rico Planning Board. In the Virgin Islands, the Department of Planning and Natural Resources permit constitutes compliance with the Coastal Zone Management Plan.
REQUEST FOR PUBLIC HEARING: Any person may request a public hearing. The request must be submitted in writing to the District Engineer within the designated comment period of the notice and must state the specific reasons for requesting the public hearing.
DEPARTMENT OF THE ARMY
JACKSONVILLE DISTRICT CORPS OF ENGINEERS
9900 SOUTHWEST 107TH AVENUE, SUITE 203
MIAMI, FL 33176
November 17, 2017
REPLY TO
ATTENTION OF
Regulatory Division
South Permits Branch
Miami Permits Section
PUBLIC NOTICE
Permit Application Number SAJ-1998-02950 (SP-NDF)
TO WHOM IT MAY CONCERN: The Jacksonville District of the U.S. Army Corps of
Engineers (Corps) has received an application for a Department of the Army permit
pursuant to Section 10 of the Rivers and Harbors Act of 1899 (33 U.S.C. §403) as
described below:
APPLICANT:
HSH Willisle Marina Company, LLP
c/o Scott Huizenga
7900 Glades Road, Suite 402
Boca Raton, FL 33434
WATERWAY AND LOCATION: The project would affect waters of the United States
associated with Maule Lake, to the west of Dumfoundling Bay. The project is located
within Williams Island at 4100 Island Boulevard, in Section 10, Township 52 south,
Range 42 east, City of Aventura, Miami-Dade County, Florida (Folio Number 28-2210
066-0023).
Directions to the site are as follows: From I-95 north, exit on Ives Dairy Road (NE
203street). Turn right onto Ives Dairy Road, bear right onto US-1 (Biscayne Boulevard),
and turn left onto NE 183rd street (Williams Island Boulevard).
APPROXIMATE CENTRAL COORDINATES:
Latitude
Longitude
25.941111°
-80.136111°
PROJECT PURPOSE:
Basic: The basic project purpose is to improve vessel access.
Overall: The overall project purpose is to improve vessel access within Williams Island,
City of Aventura, Miami-Dade County, Florida.
EXISTING CONDITIONS: The upland areas adjacent to the project sites consist of a
multifamily residential development and associated recreational and parking areas. The
work areas are located within the Williams Island Marina, a partially-enclosed basin with
the perimeter of the basin supporting mangrove trees.
A site inspection performed by Coastal Systems International on November 3, 2017
indicates that water depths within the survey area ranged from approximately 4 to 16
feet deep, with the deepest water occurring at the north portion of the survey area in the
center of the slip footprints. The submerged lands within the survey area consisted
mostly of sand with high concentrations of silt and organic material, dense aggregations
of oyster shells, sporadic man-made debris, various upland vegetative debris primarily
from Red Mangrove (Rhizophora mangle) leaves in the area near the floating dock and
Australian Pine (Casuarina equisetifolia) west of the floating dock. Based on site
observations during the survey, the top 6 feet of water in the survey area was made up
of primarily freshwater. Visibility within the marina was generally very good
(approximately 10 feet) in the freshwater layer as there was little suspended sediment in
the water column and the tannin levels in the water were moderate.
At a depth of 6 feet, a very prominent hydrogen sulfide rich layer was apparent, likely
due to a combination of the decayed organic material and the lack of water circulation.
Below the hydrogen sulfide rich layer, saltwater was present but light levels were
drastically reduced. Within the salt water layer (from 6 feet below the surface to the
bottom) the visibility was generally low (less than 3 feet) due to a combination of the
easily suspended sediment in the water column, the effects of hydrogen sulfide rich
layer separating the freshwater and saltwater, and the reduced light levels due to the
tannins in the freshwater layer above.
No seagrass, macroalgae, sponge, or coral species were observed colonizing the
surface of the existing floating dock or growing on the substrate within the Project area.
Commonly observed fish species within the Project area included the primarily
freshwater Mosquitofish (Gambusia affinis) which gathered in schools around the
floating dock from the surface down to a depth of approximately 4 feet. Just below the
freshwater layer, juvenile Gray Snapper (Lutjanus griseus), juvenile Great Barracuda
(Sphyraena barracuda), and assorted Blenny species were observed. No fish species
were observed in or below the hydrogen sulfide rich water layer, from 6 feet below the
surface to the bottom.
PROPOSED WORK: The applicant seeks authorization for (1) the replacement of
floating docks in the same footprint; (2) installation of finger piers; (3) reallocation of 106
powerboat slips based on actual usage patterns as follows:
North Marina:
Four existing 66-foot long slips will be converted into two 130-foot long slips. No
additional structures to be installed in this area.
North Lagoon Marina 1:
Replacement of a 7.6 foot wide by 338.3 foot long floating dock (2,576.3 square feet)
and installation of eight 5.9 foot wide by 29 foot long (171.1 square feet each) finger
piers and one 11.1 foot wide by 29 foot long (321.9) finger pier. The finger piers will be
2
secured by 15 wood piles and will be connected to the uplands by an aluminum
gangway.
North Lagoon Marina 2:
Four existing 53-foot long slips will be converted into three 87-foot long slips. No
additional structures to be installed in this area.
Island Club Marina:
Northwest Corner: Two existing 70-foot long slips will be converted into one 130-foot
long slip. No additional structures to be installed in this area.
Southeast Corner: Two 20-foot long slips will be created. No additional structures to be
installed in this area.
West Marina:
Ten existing 76-foot long slips will be converted into three 136-foot long slips and three
117-foot long slips. No additional structures to be installed in this area.
Temporary turbidity curtains will be deployed and remain in place for the duration of all
in-water activities in/over waters of the United States. The work is proposed in
accordance with the attached site plans.
AVOIDANCE AND MINIMIZATION INFORMATION The applicant has provided the
following information in support of efforts to avoid and/or minimize impacts to the
aquatic environment:
"Turbidity curtains will be installed during the replacement of the pilings in North Lagoon
Marina 1. All watercraft associated with the construction of the proposed floating dock
will only operate within waters of sufficient depth to preclude damage to the submerged
lands and resources; sufficient depth can be defined as one-foot of clearance from the
deepest draft of the vessel to the top of any submerged resources. Please note that this
is the only proposed construction for this permit application.
The shoreline adjacent to the area where the proposed floating dock will be replaced
also supports mangroves. Please note that the mangrove trees along the shoreline of
the North Lagoon Marina 1 will not be impacted, as construction will occur from a barge.
In addition, no mangrove tree trimming is proposed."
COMPENSATORY MITIGATION The applicant has offered the following
compensatory mitigation plan to offset unavoidable functional loss to the aquatic
environment:
"No dredging activities are proposed as part of this permit application. The mangrove
trees along the shoreline of the North Lagoon Marina 1 will not be impacted, as
construction will occur from a barge. No mangrove tree trimming is proposed as part of
this Project's scope; the mangrove trees have subsisted along the Williams Island North
3
Lagoon Marina shoreline since at least 1987, and there are no plans to eradicate the
healthy trees. No shoreline construction is being proposed. "
CULTURAL RESOURCES: The Corps has determined the permit area activity is of
such limited scope there is little likelihood of impact upon a historic property; therefore,
the proposed project would have "No Potential to Cause Effect".
By copy of this public notice, the Corps is providing information for review. Our final
determination relative to historic resource impacts is subject to review by and
coordination with the State Historic Preservation Officer.
ENDANGERED SPECIES: The U.S. Army Corps of Engineers (Corps) has determined
the project may affect the West Indian manatee (Trichechus manatus), American Crocodile
(Crocodylus acutus), green sea turtles (Chelonia mydas), loggerhead sea turtles (Caretta
caretta) and designated critical habitat, hawksbill sea turtles (Eretmochelys imbricata),
Kemp's ridley sea turtles (Lepidochelys kempii), leatherback sea turtles (Dermochelys
coriacea), smalltooth sawfish (Pristis pectinata), Nassau Grouper (Epinephelus striatus).
The Corps has determined that the proposed project would cause the following effects
on federally listed species:
a. West Indian Manatee: Potential impacts were evaluated using the Corps of
Engineers, Jacksonville District, and the State of Florida Effect Determination
Key for the Manatee in Florida (Manatee Key) dated April 12, 2013. Use of the
Manatee Key resulted in the following sequential determination: A > B> C > G >
H > I > J > K > "May Affect". The project site is not located in a warm water
aggregation area; however, the project has not been reviewed by the Florida Fish
and Wildlife Conservation Commission or the U.S. Fish and Wildlife Service
(FWS) and confirmed consistency with the Miami-Dade County Manatee
Protection Plan has not been provided. Therefore, formal consultation with the
FWS is required.
b. Swimming Sea Turtles and Smalltooth Sawfish: The Corps has determined
the proposed project "may affect, but is not likely to adversely affect" green sea
turtles, loggerhead sea turtles, hawksbill sea turtles, Kemp's ridley sea turtles,
leatherback sea turtles, and smalltooth sawfish. The Corps evaluated the
proposed work utilizing NMFS's Statewide Programmatic Biological Opinion
(SWPBO) dated December 4, 2015 and has initiated the Tier II process
established in the SWPBO reviews.
A "no effect" determination was reached on the American Crocodile. Consultation with
Service Agencies is not required for determination of "no effect
The Corps has determined the proposal will not affect any other threatened or
endangered species or designated critical habitat other that the species listed above.
4
ESSENTIAL FISH HABITAT (EFH): This notice initiates consultation with the National
Marine Fisheries Service on EFH as required by the Magnuson-Stevens Fishery
Conservation and Management Act 1996. The proposal would impact approximately
4,188 square feet of submerged bottom utilized by various life stages of marine species.
Our initial determination is that the proposed action would not have an adverse impact
on EFH or Federally managed fisheries. Our final determination relative to project
impacts and the need for mitigation measures is subject to review by and coordination
with the National Marine Fisheries Service.
NOTE: This public notice is being issued based on information furnished by the
applicant. This information has not been verified or evaluated to ensure compliance with
laws and regulation governing the regulatory program. The jurisdictional line has not
been verified by Corps personnel.
AUTHORIZATION FROM OTHER AGENCIES: A Water Quality Certification may be
required from the Florida Department of Environmental Protection and/or one of the
state Water Management Districts.
COMMENTS regarding the potential authorization of the work proposed should be
submitted in writing to the attention of the District Engineer through the Miami Permits
Section, 9900 Southwest 107the Avenue, Suite 203, Miami, Florida 33176 within 21
days from the date of this notice.
The decision whether to issue or deny this permit application will be based on the
information received from this public notice and the evaluation of the probable impact to
the associated wetlands. This is based on an analysis of the applicant's avoidance and
minimization efforts for the project, as well as the compensatory mitigation proposed.
QUESTIONS concerning this application should be directed to the project manager,
Nicole Fresard, in writing at the Miami Permits Section, 9900 Southwest, Suite 203,
Miami, Florida 33176; by electronic mail at Nicole.D.Fresard@usace.army.mil; by
facsimile transmission at (305) 526-7184; or, by telephone at (305) 779-6053.
IMPACT ON NATURAL RESOURCES: Coordination with U.S. Fish and Wildlife
Service, Environmental Protection Agency (EPA), the National Marine Fisheries
Services, and other Federal, State, and local agencies, environmental groups, and
concerned citizens generally yields pertinent environmental information that is
instrumental in determining the impact the proposed action will have on the natural
resources of the area.
EVALUATION: The decision whether to issue a permit will be based on an evaluation of
the probable impact including cumulative impacts of the proposed activity on the public
interest. That decision will reflect the national concern for both protection and utilization
of important resources. The benefits, which reasonably may be expected to accrue from
the proposal, must be balanced against its reasonably foreseeable detriments. All
factors which may be relevant to the proposal will be considered including cumulative
5
impacts thereof; among these are conservation, economics, esthetics, general
environmental concerns, wetlands, historical properties, fish and wildlife values, flood
hazards, floodplain values, land use, navigation, shoreline erosion and accretion,
recreation, water supply and conservation, water quality, energy needs, safety, food,
and fiber production, mineral needs, considerations of property ownership, and in
general, the needs and welfare of the people. Evaluation of the impact of the activity on
the public interest will also include application of the guidelines promulgated by the
Administrator, EPA, under authority of Section 404(b) of the Clean Water Act or the
criteria established under authority of Section 102(a) of the Marine Protection Research
and Sanctuaries Act of 1972. A permit will be granted unless its issuance is found to be
contrary to the public interest.
The US Army Corps of Engineers (Corps) is soliciting comments from the public;
Federal, State, and local agencies and officials; Indian Tribes; and other Interested
parties in order to consider and evaluate the impacts of this proposed activity. Any
comments received will be considered by the Corps to determine whether to issue,
modify, condition, or deny a permit for this proposal. To make this determination,
comments are used to assess impacts to endangered species, historic properties, water
quality, general environmental effects, and the other public interest factors listed above.
Comments are also used to determine the need for a public hearing and to determine
the overall public interest of the proposed activity.
COASTAL ZONE MANAGEMENT CONSISTENCY: In Florida, the State approval
constitutes compliance with the approved Coastal Zone Management Plan. In Puerto
Rico, a Coastal Zone Management Consistency Concurrence is required from the
Puerto Rico Planning Board. In the Virgin Islands, the Department of Planning and
Natural Resources permit constitutes compliance with the Coastal Zone Management
Plan.
REQUEST FOR PUBLIC HEARING: Any person may request a public hearing. The
request must be submitted in writing to the District Engineer within the designated
comment period of the notice and must state the specific reasons for requesting the
public hearing.
6
Sheet List Table
Sheet# Sheet Title
8
PROPOSED NORTH LAGOON MARINA 1
9
PROPOSED NORTH IJ\GOON MARINA 2
1
COVER SHEET
10
PROPOSED ISLAND CLUB MARINA
2
EXISTING NORTH MARINA
11
PROPOSED WEST MARINA
3
EXISTING NORTH LAGOON MARINA 1
12
UTILITY' ROUTING PLAN
4
EXISTING NORTH LAGOON MARINA 2
13
UTILITY' DETAILS - 1
5
EXISTING ISLAND CLUB MARINA
14
UTILITY DETAILS - 2
6
EXISTING WEST MARINA
15
GENERAL. NOTES
7
PROPOSED NORTH MARINA
--
FLOATING DOCK DETAILS
NOTE:
MARINA BOAT SLIP RECONFIGURATION.
EXISTING NUMBER OF SUPS = 106
PROPOSED NUMBER OF SUPS = 106
GOLDEN BEACH
EXIST.
NORTH
MARINA
PROPOS.
FLOAT/Ni
DOCKS
R.oRllJA
EXIST.
WEST
MARINA
LOCATION
LOCATION MAP ~
NTS
0
"'
"'
N
u
"'
APP. NO:
PROJECT NO:
DATUM:
261601
Wlll.IAMS ISi.AND MARINA
NGVD
PERMIT SKETCHES
DESCRIPTION:
CHECKED BY:
SUBMITTED. B :
AP
4100 ISLAND BLVD. #CU- 2
AVENTURA, FL. 33160
1-11;.:.01<,.;o,~22T;-117=-7.i-;,FL~O""'ATI.,,,N,.,_G,....oo,,,,,c,,,_K_,_,R"'"'EV_,_
. ____. DRAWN BY:
DATE:
COASTAL SYSTEMS INTERNATIONAi.. iNC
464 South DMe ~
T~ :
ANDRES PEREZ
FL REG. 5 6507
J06- 661 -J655 F....
°*' Qlilor, Aollda .\3146
~-661-IRll
, ...coootolS)'Slimililt.com
STATE Of FLORIDA EB f/087
c:a-1,~(MI
........ nl~
4100 ISLAND BLVD. #CU-2
MARINA UPGRADE
COVER SHIET
SHEET 1 OF 15
NORTH MARINA
r
LOCATION MAP
;- -
--- -
- - - -
-
- - - -- - - - -
~
7000
ISLAND BOULEVARD
L _J L
_J
L
_l
L_J L__J
MARIN. A BASIN
1
I
Ill
1
1
1
- 1111
I It) 11 ~ I
1- 11-1
!:!:,
~
l t;l ll<.ril
n
SC.4LE IN FEET
1'' = 80'
APP. NO:
1 ---=----1-'----- - - - -1 PROJCCT
t;
NO
261601
I:
Wll.IMI ISi.AND ~
4100 ISlAND BLVD. #CU-2
A\£NTURA, fl. 33160.
DATE:
DESCRIPTIOI~
CHECKED BY:
SUBMI ED Bf:
COASTAL SVSTI:MS JNTtRNATIONAl. INC
N>
4100 ISLAND Bl.VD. #CU-2
MARINA UPGRADE
404 5oom Oido ~y. COAi C&bb, !lonpa 3ll~
Toi: 3()5 -~1 -~ r o>: ~661- 1 9 1 4 ...w.coost~.stANDRES PEF!E Z
FL REG. 66507
Sl'All OF fLO~ID~ EB f70ffl
Coutol. r:n.lrm.....W, CM rt>gln..... .,,., Ma....,,-er1t
'SHEET
2
OF 15
MAIN MARINA- 1
\
LOCATION MAP
~
NORTH
LAGOON
EASTMENT
EXIST 4'
ALUM C.L. F.
\
\
XISTING
FLOATING
DOCKS T
REPLACE
BE
NORTH
LAGOON
EASTMENT
D
EXIST
ALUM GATE
0
to
r-,
./
1l 0
25
·e
H-J
I
~
50
SCALE IN F~ET
---~ 1
I
'
MAlOfUNE · REFEl 10 SHEEr 4
APP. NO:
1 -----'--i..,___ _ _ __ _ PROJECT
NO:
261601
DA.TUM:
DRAWM BY:
DESCRIPTIOM
CHECKED BY:
SUBMITTED BY:
COASTAL SYSTEMS INTERNATIONAL, INC.
~ South ~ ...,_y, Coral Cobleo, florid· 3:1146
Tel: S'.>5- 1»1- .lf>55
ANDRES PEREZ
FL REG. 66507
Fo~
EXIST
--/SIDEWALK
=-...!__
~\~ 11
W111Mti ISlAND MADIA
4100 ISLAND Bl\1>. fCU-2
AVENTURA, Fl 33160
4100 ISLAND BLVD. fCU-2
MARINA UPGRADE
305- 661- 1914 .......CcostoSl';stSTAIE OF FLORIOh EB f7087
Q>&ml, &Mmnlnl!rTl&\. CMI
rn~
an:l Mo.nagtme><
-
SHEET
3
OF
15
LOCATION MAP
~
(IJ
y
(.)
0
0
I
\
'NORTH LAGOON
EASEMENT
\
i~
E
v
(L
_,,,,
..
=
=
"'!
~
·5- 0,.....__, 40
(
<.!)
-~, -
80
MATOIUNl · RfflR 10 SHEET 5
~· SC~L,,f ~N ~ft T
8
\;
APP. NO:
1 ----=---
l-'- - - - - - - - - -1 PROJ[[.T NO~
261601
I:
Wll.IMI ISi.AND MMttlA
4100 ISlANO BLVD. fCU-2
AVENTURA, fl. 33160
DATE~
DESCRIPTIOI~
CHECKED SY:
SUBMI ED Bf:
COASTAL SVSTI:MS INTIRNATIONAL. INC
N>
4100 ISlAND Bl.VD. #CU-2
MARINA UPGRADE
404 5oom OiOO ~y, COAi C&l)b, !loriPa 111~
M: ,l()!H»1 ·~ ra>: l05-661-1914 ...w.coost~.ilANDRES PEREZ
FL REG. 66507
SfA!E OF fLO~ID~ EB f/Offl
Coutlll, cnwtn....ul, CM1 rng1n-.
.,,., Ma._.,...,,
3HEET
4
OF 15
"
EXISTING 6.5' WIDE
CONC. OVER WATER
DOCK W/ 12· WO.
FENDER PILES
/ ~)
/s0? ,;;,.,,;
< /.
r1':
~
I Q.:.. I'
.
ISLAND CLUB
I ~ 1,'
l Vj-,/f
'
EXIST CONC PIER, lYP.
i '='
E
"'
a_
/
10
0
80
SL'ALE IN FEET
;_;
APP. NO:
l -- ' - -1-' - -- - - - -I PROJCCT NO:
·
·
DATUM:
SUBMI ED BY'.
ANDRES PEF!E Z
FL REG. 66507
261601
I:
Wll.IMI ISi.AND ~
4100 ISlANO BLVD. #CU-2
AVENTURA, fl. 33160.
4100 ISLAND Bl.VD. #CU-2
MARINA UPGRADE
'SHEET
5 OF 15
EXIST---"'
SEAWALL
I
EXIST-
-
PROMENADE
LOCATION MAP ~
WALKWAY
,,,
""lt..i Ito
EXISTING 9.5; WIDE
CONC. OVER WATER
DOCK W/ 12· WO.
FENDER PILES
jl
'-1
s/
!t
//
~'
\
.I
~
i '='
E
"'
/
a...
~EX IST
1l}
SEAWALL
0
1-1-1
100
50
I
SCALE JN FEET
1'' = 100'
APP. NO:
l -- ' - -l·..__- - - - -1 PROJCCT NO:
·
·
G
261601
DATUM:
I:
~JSl.AND~
4100 ISlANO BLVD. #CU-2
A\£NT\JRA, fl. 33160.
4100 ISLAND Bl.VD. #CU-2
SUBMI ED BY'.
COASTAL SVSTI:MS INTtRNATIONAt.. INC
MARINA UPGRADE
404 5oom Oido ~y. COAi C&l)b, !loriQa 3ll~
Toi: 3()5 -~1 -~ r o>: ~661- 1 9 1 4 ...w.coost~.Jt/\NOR ES PEF!E Z
FL REG. 66507
SfAll OF fLO~ID~ EB f70ffl
Coutol. r:nwm.....w, CM rt>gin..... .,,.,
Ma....,,,,"
SHEET
6
OF 15
NORTH MARINA
r
SUPS CONVERSION:
4 EXIST. 66' SUPS
LOCATION MAP
TO 2 PROPOSED 130' SLIPS
~
NO ADDmONAL STRUCTURES
TO BE INSTALLED.
7000
ISLAND BOULEVARD
,_____,! ...
1_
· --
~~
"':.
'~
~
~
~
~
~
tr;
__,
'·')
tr;
~
~
<'J
I
c
0
REVISED SUP COUNT
:@:
/9~
52
§
~
4
DIFFERENCE - 2
MARINA
BASIN
./
·if'
~
-[)
-"'-
- ,....,
(/)
Cl:;
,.._
~
(rj
"'..--.
~
l;-i
'c
-.
~
'-
~
(rj
9::
~
Vj
Q
~
(rj
l -- - ' - -l-'----- - - - -1 PROJ[CT NO~
~
~
i?5
261601
DATIJM:
Wll.IMI ISi.AND ~
4100 ISlANO BLVD. fCU-2
AVENTURA, fl. 33160
4100 ISi.AND Bl.YD. #CU-2
SUBMI ED Bf:
COASTAL SVSTI:MS INTIRNATIONAL. INC
MARINA UPGRADE
404 5oom OiOO ~y, COAi C&l)b, !loriPa 111~
M: .l()!H»1 ·~ ra>: l05-661-1914 ...w.Coost~ilANDRES PEREZ
FL R£G. 66507
SfA!E OF fLO~ID~ EB f/Offl
Coutoi. cnwtn....ul, CM1 rng1n- . anti
Man_,,..,,,
SHEET
7
OF
15
-k-csu~;.
T-
MAIN MARINA- 1
89
~'
l sup No. 88
·
L _- - - - ~
\ SUP No. 87
L - '"-<=""-'°'""~'11
LOCATION MAP ~
\
I
.
I SUP No. 85
----11"""11··-
L -
[sup ~o_:_84
l
I
:
I
I
[sup ~o~ 86 _ ~
\
7'-t
_
SLIP No. 83
-~-1
L= .,
[ SLIP_!fo. 82_
I
.___
I - t - - PROPOSED
FLOATING DOCK
I SLIP No. 81
I
L - ....,,_...---..
11,
·
PROPOSED FLOATING----=
,,n~A'a-.--'~
1--=r='
FINGER DOCK, lYP.
JU> ! VI
80
\
~
\-SLIP- No. 79 -
L - ~
.,:2!'1Sr_-u"~
(JI
12
'
SLIP INo. 75
I
-.....
I
N
]
FLOATING DOCK AREA:
'§
MAIN PIER =
2,576.3 S.F.
FINGER PIERS = 1.611.7 S,f,
TOTAL AREA =
4,188.0 S.F.
(· Areas per dock manufacturer)
..
l
"
SLIP No. 76
I
L- +
3:
~
78 _ ~
-
I
/
o
to
-
· I SLIP No. 77
18
~I DIFFERENCE + 6
c
:8
g- NOTE:
~ FOR UTILITIES,
REFER TO SHED 12
0~
$
,
~ ~ LSLIP_!lo.
REVISED SUP COUNT
EXISTING
PROPOSED
L -
_.-.
29' FINGER
DOCK lYP.
-
-
~\a?. [sup!~ 74 ~ 1 ·
I SUP No. 73
I
;
_. I SLIP No. 12
"?.
L_ _ _ _
0
·
·~ 15 - 14"- x 36' ICP SUPPORT PILES
~ (19.7' EMBEOMENT)
MATOtUNE · REffl TO SHEEr 9
Cllt 1~ 1 :
APP. NO:
l -- ' - - l - . , _ _ - - - -- 1 PROJECT NO:
261601
DA.TUM:
11/02/17 ~TING DOCK REV.
DRAWM BY:
1UF12/17 PERMIT
DATt :
DESCRIPTIOM
CHECKED BY:
SUBMITTED BY:
COASTAL SYSTEMS INTERNATIONAL., INC.
~ South ~ ...,_y, Coral Cobleo, florid· 3:1146
Tel: S'.>5- 1»1- .lf>55
Fo~
305- 661- 1914 .......CcostoSl';stSTAIE OF FLORIOh EB f7087
C<>&ml. &Mmnlnl!rTl&\. CMI rn~ an:l Mo.nagtme><
50
SCAL[ IN f [ET
J" = 50'
t>
ANDRES PEREZ
FL. REG. 6650 7
25
L-~ -~io-1-J
I
W111Mti ISlAND MADIA
4100 ISLAND Bl\1>. fCU-2
AVENTURA. Fl 33160
4100 ISLAND BLVD. fCU-2
MARINA UPGRADE
PROPOSB> NORlH LAOOON MAIM\ 1
SHEET
8 OF 15
I
LOCATION MAP
~
SUPS CONVERSION:
4 EXIST. 53' SUPS TO
3 PROPOSED 87' SUPS
NO ADDffiONAL STRUCTURES
TO BE INSTALLED.
I
I
=
REVISED SUP COUNT
l.D
"" 0
--£
·5- ,....wJ
40
PROPOSED
3
EXISTING
80
4
DIFFERENCE - 1
I
~ SC~L,f~N ~fET
8
G
APP. NO:
NO:
261601
DESCRIPTIOI~
CHECKED BY;
SUBMI ED BY:
N>
1---=----~'-------· pRQJECT
DATE:
COASTAL SVSTI:MS JNTIRNATIONAL. INC
I:
~JSl.AND~
4100 ISlAND BLVD. #CU-2
A\effiJRA, FL 33160
4100 ISLAND Bl.VD. #CU-2
MARINA UPGRADE
404 5oom OiOO ....,,.,.y, COAi C&bb, !lonpa ?J't46
Toi:
ANDRES PEREZ
FL. REG. 66507
3(XH»1 ~~
r o>:
~661- 19 1 4
...w.COosti:&J.stSfAIT OF fLO~ID~ EB f7087
Co&ttW. r.wm........i, CM Fngin..... &nd Man..,,,en<
'SHEET 9 OF 15
MATOl.t4E · REffl TO SHf!T 9
-----------
- --\- \_,,,./-~
~,
\\
'
\
\
\
\
'
SUP CONVERSION:
2 EXIST. 70' SUPS
1 PROPOSED 130' SUP
NO ADDITIONAL
STRUCTIJRES TO BE
IN
2 - NEW 20' SLIPS
NO ADOffiONAL
STRUCTIJRES TO
BE INSTALLED.
/
(~
-
=-_/f'v-.._.J
2000 ISLAND BOULEVARD
REVISED SLIP COUNT
EXISTING
PROPOSED
2
WEST MARINA
LOCATION MAP
~
NEW
DIFFERENCE + 1
1" =
G
NO:
261601
I:
Wl.l.INtG JSlAND MADIA
4100 ISl.AND BLVD. #CU-2
A\effiJRA, fl. 33160
DATE:
DESCRIPTIOI~
CHECKED BY;
SUBMI ED BY:
COASTAL SYSTI:MS JNTtRNATIONAL, INC
404 swm OiOO ....,_y, COAi Cl.blot, tlorida m~
ANDRES PEREZ
FL. REG. 66507
80
5(,'AL£ IN FEU
APP, NO:
1---=---~'--------1 PROJECT
40
0
2
1
N>
4100 ISLAND Bl.VD. #CU-2
MARINA UPGRADE
Toi: 306 -~1 -.365 ror. ~661- 19 1 4 ""W.COostaS>'J.3\C<>olml. £1'Mrm""""1, CM mp-. Ind Manapn"''
SHEET 10 OF
15
WEST MARINA
LOCATION MAP
~
SLIPS CONVERSION:
10 EXIST. 76 SUPS TO
3 PROPOSED 136' SLIPS
1
(94, 95. 96)
3 PROPOSED 117' SUPS
(97, 98. 99)
NO ADDITIONAL STRUCTIJRES
TO BE INSTALLED.
REVISED SUP COUNT
EXISTING
PROPOSED
10
DIFFERENCE - 4
50
100
1-·
SCALE JN FEET
0
6
I
1" = JOO'
APP, NO:
1 ---<--- l-'-- - - --
·
·
I PROJCCT NO:
DATUM:
t;
261601
I:
Wll.INfl ISi.AND ~
4100 ISlANO BLVD. fCU-2
AVENTURA, FL 33160
SUBMI ED Bf:
ANDRES PEF!E Z
FL REG. 66507
4100 ISLAND Bl\ID. #CU-2
MARINA UPGRADE
3HEET
11
OF
15
r-
SLIP 89
L-
_:;:::;-
*· HOPE DOMESTIC WATERLINE
---1
SLIP 88 1 -
l_ _
SLIP 87 I
L _
,-
_;=- -- II
2 JS· HOPE FIRE LINE
SLIP 86 I
LOCATION MAP
~
SLIP 84
®
ARE HOSE AND CABINET lYPE
FC-1 WITH 2 ~"CONNECTION.
100' HOSE AND 20LB
EXTINGUISHER, lYP.
®
ELECTRICAL/WATER PEDESTAL
WITH ~r CONNECTION, TYP.
- --- - ~;...._--1
SLIP 82
2" HOPE DOMESTIC WATERLINE
SLIP 81
SUP 80
4" HOPE FIRE LINE
SLIP 79
SLIP 78
~-
SLIP 77 ["""' -
NOTES:
2.
4·x2 ~· FIRE LINE REDUCER
~-
SLIP 83 l
L -
LEGEND
1.
~----!.'.
SLIP 85 IL _
,-
~
L - ~------11
FOR UTILITY DETAIL.
REFER TO SHEET 13
SLIP 76
TO 14.
SLIP 75 L _ ~~~
L- - - l
,-
FOR POWER TO
PEDESTAL REFER TO
ELECTRICAL PLANS
SLIP 74
l_ _ - - l
SLIP 73 L _ .-;::::::...-
SLIP 72 [
0
to
4· FIRE LINE CONNECT
TO UPLAND WAlER MAIN.
- -u
=-__
2· DOMESTIC CONNECT
TO UPLAND WAlER MAIN
--~---
./
1l
·e 0H-J 25
50
\
I
~
I!
SCALE IN FEET
APP. NO:
--~-1-~-----11 PROJECT
NO:
261601
DAJUM:
DRAWM BY:
DESCRIPTIOM
CHECKED BY:
SUBMITTED BY:
COASTAL SYSTEMS INTERNATIONAL, INC.
~ South ~ ...,_y, Coral Cobleo, florid· 3:1146
Tel: S'.>5- 1»1- .lf>5:5
ANDRES PEREZ
FL REG. 66507
Fo ~
Wl1IMti ISlAND MADIA
4100 ISLAND Bl\1>. fCU-2
AVENTURA. Fl 33160
4100 ISLAND BLVD. fCU-2
MARINA UPGRADE
305- 661- 1914 .....CcostoSl';stSTAIE OF FlORIOh EB f7087
C<>&ml. &Mmnlnl!rft&), CMI rn~ an:l Mo.nagtme><
SHEET
12 OF 15
3· HIGH TOP
SLOPE: 1:2
flDURECENT WMINAIRE
PROVIDE PIATE W/ INSCRIPED
WITH (2) PL-7 LAMPS
L.ETI'ERS INDICATING SOURCE
CIRClAT
BR£NPOWDER-ro\TEO
AUJINUM OR
STAINLESS STEEL CASE,
TYP.
RECEPT.
RECEPT.
WATER FAUCET
SECOlllAR'f RUN
UGHT RUN
WIE;.
1.
UTlf1Y PEDESTAL EQUIPMENT TO BE PROVIDED
B'f MARINA POWER CO. MIAMI FLORIDA OR
EQl.WAL£NT.
2.
REFER TO MARI~ ELECTRICAL CONSTRUCTION
PLANS.
llPICAL UTIUIY PEDESTAL DETAIL
N.T.S.
EXISTING COHC. BULKHEAD
PROPOSED FLEXIBLE CONDUITS W/ STAIM.ESS STEEL SJRN>S
Cl.MFS AND SUPPORT. TtPICAL FOR FIRE, OOMESTIC.
FOR ELfCTRICAL SERVICES, REFER TO ELECTRICAL PLANS.
FLEXIBLE UTILITY CONNECTION DETAIL
N.T.S.
APP. NO:
-~--l-'-------11PROJECT
NO:
261601
DA.TUM:
DRAWM BY:
DESCRIPTIOM
CHECKED BY:
SUBMITTED BY:
COASTAL SYSTEMS INTERNATIONAL, INC.
~ Scul:h OWo .........y.
Tel:
ANDRES PEREZ
FL REG. 66507
S'.>5 -Ul-~
Fo~
Ccal c.w... florid· 33146
305- 661- 1914
1111W.Coast~stems11t.com
STAIE OF FLORIOh EB f7087
C<>&ml, &Mtm.......i, (Ml Fn~ and
Me._.,,,
LS
\W1IMti ISlAND MADIA
4100 ISLAND BL\1>. fCU-2
AVENTURA, FL 33160
4100 ISLAND BLVD. fCU-2
MARINA UPGRADE
UllJIY DHAIS ·1
SHEET 13 OF
15
·
POWDER COATED
MARINE-GRADE
ALUMINUM CA.SE (WHITE} ~~======~
PROVIDE
BOLD RED LETTERS
STAINLESS STEEL HINGES
STAINLESS STEEL
WASHERS 0 BASE
STAINLESS STEEL LOCK
2-1/2· BEND GAlV.
(COLOR RED)
2-1 /2· FIRE DEPT. ANGl£
VALVE (OOONZE)
4-WAY ADJUSTABLE
PLASTIC NOZZLE
(ON/OFF/STRAIGHT/FOG)
1- 1/2· HOSE SUPPORT
20LB CLASS A/B/C PORTNl.E
100FT OF' 1-JS·
~
Fl£XIBLE ARE HOSE
4· HOPE
ARE EXTINGUISHER
GAlV. "U· CLAMP AND
SUPPORT COLOR RED (lYP.)
ARE LINE
ARE CAlllEf NOTE5c
1. C.ABINETS AND FIRE PROTECTION EQUIPMENT SHALL MEEJ tffA 14
&: JOJ, CllY OF MIAMI FfiE DEPARTMENT AND FLORIDA BUILDING
CODE REQUIREMENTS.
2. CONTRACTOR TO SUPPLY SHOP DRAWING FOR CABINETS ANO
MOUN114G SYSTEM TO COMPLY WITH !\EPA 13 t 14.
3. CABINET SHAll BE
~NA
POWER COMPANY fC-1 OR EQUIVALENT.
4. REFER TO FIRE PROTECTION CONSTRUCTION PLANS
RRE CABINET AND HOSE ASSEMBLY DETAIL
N.T.S.
APP. NO:
-~--l-'-------11PROJECT
NO:
261601
DA.TUM:
DRAWM BY:
DESCRIPTIOM
CHECKED BY:
SUBMITTED BY:
COASTAL SYSTEMS INTERNATIONAL, INC.
~ Scul:h OWo .........y.
Tel:
ANDRES PEREZ
FL REG. 66507
S'.>5 -Ul-~
Fo~
Ccal c.w... florid· 33146
305- 661- 1914
1111W.Coast~stems11t.com
STAIE OF FLORIOh EB f7087
C<>&ml, &Mtm.......i, (Ml Fn~ and Menegemen<
LS
\W1IMti ISlAND MADIA
4100 ISLAND Bl\1>. fCU-2
AVENTURA. FL 33160
4100 ISLAND BLVD. fCU-2
MARINA UPGRADE
UllJIY DHAllS ·2
SHEET 14 OF
15
GENERAL NOTES:
1. TOPOGRAPHIC DATA TAKEN FROM SURVEY PERFORMED BY PILLAR CONSULTANTS INC. ON OCTOBER 22,
2010.
2. B.EVATIONS ARE RELATIVE NATIONAL GEODETIC VERTICAL.. DATUM OF 1929 (NGVO).
3. THESE DRAWINGS ARE ·PERMIT SKETCHES· INTENDED TO PROVIDE SUFFICIENT DATA FOR REVIEW AND
EVALUATIONS BY REGULATORY AGENCIES. THESE DRAWINGS ARE NOT INTENDED FOR CONSTRUCTION.
4. CONTRACTOR TO INSTALL ANO MAINTAIN FLOATING TURBIDITY BARRIERS DURING ALL PHASES OF
MARINE CONSTRUCTION.
5. CONSTRUCTION MAY BE COMPLETED WITH BARGE-BASED EQUIPMENT WHILE MAINTAINING A
MINIMUM OF ONE FOOT DRAFT CLEARANCE BETWEEN BOlTOt-4 OF FULLY LOADED BARGE AND
SUBSTRATE.
DATIJM DIACRAM
--...--MHW
----NGVD
~
C-1.55' NAVO>
---'---MLW
SOURCE :
LABINS 1140
CLl t NI :
APP. NO:
a-~-1-~-----11PROJECT
NO:
261601
DA.TUM:
11 m:1117 FLOl.11NG DOCK REV.
10/12/17
DAT~:
l'tJMT
DRAWM BY:
DESCRIPTIOM:
CHECKED BY:
SUBMI TTED BY:
COASTAL SYSTEMS INTERNATIONAL, INC.
~ South ~ Hlill!Wty,
N.T.S.
Wl1IMti ISlAND MADIA
4100 ISLAND Bl\1>. fCU-2
AVENTURA. FL 33160
4100 ISLAND BLVD. fCU-2
MARINA UPGRADE
CoAI Cobleo, florid· 3:1146
Tel: 315- 661-3655 Fox: 305-661-1914 · ··.CoastdSystANDRES PEREZ
FL REG. 6650 7
STAIE or FLORIDh EB 17087
C<>&ml, &Mmn""""'~ CM Fngine<
SHEET 15 OF
15
5
4
7
8
9
10
12
11
LEGEND
~
ALUMINUM GANGWA.Y
16.7
MHWL + 1.75' NGV D
t.Sm X 7.6m
(5" x 25']
.l{./
EXtsTING CONCRETE
rl X£0 DOCK
ALUMINUM BOTTOM
; , ~
'
A
MLWL + 0.43' NGVD
ALUMINUM TOP
TRANSITION PLATE
NGVD +5.20"
~pp~0'1~\.
~
6.8
A
TRANSITION PLATE
·· -t,
B
GANGWAY FLEXIBLE CONNECTION
ON CONCRETE SLAB
______
r...... .,.___.,.______.,.__ _____ ....
-------.. ---
y__
.,, !AHW_!-Ji~~!:°l GVQ __________ _
'"-1------------------------r--:-----------------------r---r-----------------------r--T------------------------r--T-----------------------T--J
74 mph
S(Cum'I f.ACTtwl (WIND lo.oD) : 1.5
1
roAM r 1u [o PoLrcTHlLENE FLOAT
BOOYANCY : :SS Pl1
~
---------------------------------------~----------+-~----------f-+----------i_j:-----------+-\----------J-------------l- -- ML\'!~L+_~.Q'_\_NGV_D___________ _
\' .. _ _ ______________ ___ _.. ; J
Wiii> Sf[[D :
fR£I90ARD : 18"
"r-.:.:..-.:.:.:.:.:.:-.::.::.:.:.:.:.:.:.:..-.:.::.:.:.::.:::.::.:.:.:.:.:.:.:.:.:.:-.:.:--.:.:.::.:.:.:.:.:.:.:.:.:.:.::.:.:.:~.::.:.:.:.:.:.:.:.:.::.:.:.::.:.:.:.:.:;.:.:.:.:.:.:.::.::.::.::-:.:.:.::.:.:;.:.:.:.:;.:.:.:.:.:.::.:.::.:.:.:.:..-.:.:.:.:.:.:.:.::::.::.:.:.:..
c
DESIGN CRITERIA
\' .. _ _______ ,..._ _ _ _ _ _ _ _
J
~ ·
\' .. ________________ ...._
I
...·I.
\' .. ________ __ ____ ___ _ _ ,.,,I
\' .. __ __ _______________ .....I
1/
~~ltATION\ll EW
Wl..V[ HCIGHT :
CURRENT SPUD :
r.ac.
rlXED f'1ER fl.CV.
: 1'.S.20· HGVO
W
lfNI.:
~~ CLEVATIO!&i liblH OCTAllS
r.e.c.
WAVE f'El!IOD : l.lC.
c
+us· HGVD
NGVD : {-t.!JJ' HI.YD)
WLWL : · 0.43' NG'ID
SEMO n£V4TIOH : VAAU rROW- 00'
3500
ro - 1.4'1 !Cvtl
S()(l TYPE : IBD
[ I l ' - 6"]
1524
(5']
N VM.UE : 10
INNER CL£ARANCE
BOAT PRCIFU : T09.A.SSON 1989 BOAT
PROrll.£ CUM
ALUMINUM
WElHCO Of : U.S. CORPS Of ENGINEER
TOP CHORD
D
~
1!I ;=.
sPCCIM. R£P<:lt1' 1974
CAlCut.AOON
A.LUUINUM
HANDRAIL
COWPOSITE DECKING
(SANO COLOR)
D
12· ALUMINUM MOORING Ct.EAT
COt.olPOSITE FENCER
(SANO COLOR)
Al 1. r x Posrn smr s
ALU WINUM STRINGER
-]
----~ ~ ~-----------
A l,.Ul.!1N UM
Dl A.GONAL
I'~
"~
:ri}
2~
ALUlollNUlol TOE- Pl.A I!
I
I
ALUMINUM"
STRINGER
g
COMPOSITE otCKING
(SANO COLOR)
NOTES
SITE DATA SUCH AS TIDE LEVE:LS,
BATHYMETRY. SHORE ELEVATION.
SOIL STUDY, WINO SPEED ANO WAVE
HEIGHT TO BE CONnRMEO UPON flNAL
DESIGN.
All DIMENSIONS ARE 8CTWE£N COCK
ALUt.llNUM EXTRUSIONS ONLY AND
0 0 NOT TAKE INTO ACCOUNT THE
ALUMINUM"
BOTTOM CHORD
FtHOCR WIDTHS UNLESS OTHERWlSE
NOTED.
SECTION VIEW
GLOI
FOAM FIUED POLYETHYLENE FLOAT
1 1.5' rlHGCR DOCIC CROSS StCTIOH
f:::,.
~
/::;.-+~~~--f~-+~-+~+---IF
f:::,.
ALUlollNUlol TRANSVERSAL
SECTION VIEW
GL02
GANGWAY Cf!OSS SCCTKlH WITH 0£TAILS
1540
2400
R.G.
[S'-1 "]
[7' - 10"]
1710
o.
Fob.
l"'tL
12" ALUMINUM t.olOORING CLEAT
ALUMINUM STRINGERS
ALUMINUM
ALUlollNUM STRINGER
PILE GUIDE
115
COMPOSITE DECKING
(SAND COLOR)
[5"]
G
12 " ALUUINIJM MOORING CLE.AT
COMPOSITE r ENOER
(SANO COLOR)
BOTH SIDES
/
OOMPOSJTE DECKING
( SANO COLOR)
COMPOSITE FENDER
{SANO COLOR)
OM AU. EXPOSED SIDES
3<8
(1 '- 2"]
(TYP.)
TECHNO~... MARINE
Ad vonc::ed Docking Sohrll on s
Proj«
~
l
WILLIAMS ISLAND MARINA
NORTH LAGOON FLOATING PIER
AVENTURA, FL
~
]
Project
g
0
"'
::l
::l
f:
I
------L-----------------·-----·
GENERAL LAYOUT
ELEVATION & SECTION VIEWS
·---- f:- ---------
No. de Control
Gfront de projet
6072- A
H
CMtroct M.
Tl'Oof le
r OAM n u.to POLYETH YLtNt
f LOAT
SECTION V IEW
4
R. GR1r m H
0ro ..n
Pf'l"lt«I
SECTION VIEW
Oe8*h de rtl .
MAIM WM.KwAr atoss SfCflOH
WfTH PILE O.llOE
3
Desainf 1>3r
17/10/06
FOAM f l LLEO POLYETHYLENE F'LOAT
No. de de:ssi11
6072A-GL02
Drowln9 no
Rrf. clrowlrq
5
7
8
9
10
11
12
b)'
Rew.
00
Rev