WIDENING AND EXTENSION OF COOK ROAD IN LIVINGSTON PARISH

NAME OF APPLICANT: Livingston Parish, c/o Foret Environmental Services, Inc., 9040 Briarwood Place, Baton Rouge, Louisiana 70809. LOCATION OF WORK: Within the Lake Pontchartrain Basin, in Amite River hydrologic unit (HUC 08070202). Beginning at the intersection of Louisiana Highway 16 and Cook raod, near Denham Springs, Louisiana, in Livingston Parish. CHARACTER OF WORK: The applicant has requested authorization to clear, grade, and fill an area to allow for the widening of Cook Road, construction of a new bridge over Grey’s Creek, and construction of a turnaround at the intersection of Cook Road and LA-16. The proposed bridge will consist of an 84’ x 140’ slab span, pile-supported bridge. The new bridge and widening of Cook Road will result in impacts to 2.5 acres of jurisdictional wetlands and 1.3 acres of other waters. For these impacts, the applicant has agreed to purchase wetland credits from a Corps approved bank located within the watershed of impact. The newly improved Cook Road will tie into Juban Development, which was authorized by permit number MVN 2005-4490 CZ. The Juban development permit authorized a road extending throughout the property and ending aligned with Cook Road. This road is in the process of being relinquished from the permit from Juban Development and transferred to Livingston Parish. The road has been mostly constructed in conjunction with Juban Development. However, the portion along the western boundary of the site has yet to be constructed.Livingston Parish is now proposing to modify the unconstructed portion of the authorized road to include six 8’ x 7’ x 124’ concrete box culverts and fill at the crossing of the unnamed waterway. All wetland impacts within the boundary of the original authorization have been mitigated for. No additional wetland impacts will occur as a result of this modification. Thus, no additional mitigation will be assessed for the modification of the previously permitted road.

The applicant has stated that the project has been designed to avoid and minimize direct and secondary adverse impacts to the maximum extent practicable. Any further reduction was deemed impracticable. During construction, best management practices (BMP’s) will be implemented to prevent impacts to adjacent properties.

JOINT PUBLIC NOTICE May 21, 2018 United States Army Corps of Engineers New Orleans District Regulatory Branch 7400 Leake Avenue New Orleans, Louisiana 70118-3651

State of Louisiana Department of Environmental Quality Water Permits Division Post Office Box 4313 Baton Rouge, Louisiana 70821-4313

(504) 862-2675 Project Manager Jamie Crowe Jamie.M.Crowe@usace.army.mil Permit Application Number MVN 2015-01559 CO

(225) 219-3225 Project Manager Elizabeth Hill WQC Application Number WQC 180514-01

Interested parties are hereby notified that a permit application has been received by the New Orleans District of the U.S. Army Corps of Engineers pursuant to: [ ] Section 10 of the Rivers and Harbors Act of March 3, 1899 (30 Stat. 1151; 33 USC 403); and/or [X] Section 404 of the Clean Water Act (86 Stat. 816; 33 USC 1344). Application has also been made to the Louisiana Department of Environmental Quality, Office of Environmental Services, for a Water Quality Certification (WQC) in accordance with statutory authority contained in LRS30:2047 A(3), and provisions of Section 401 of the Clean Water Act (P.L.95-17). WIDENING AND EXTENSION OF COOK ROAD IN LIVINGSTON PARISH NAME OF APPLICANT: Livingston Parish, c/o Foret Environmental Services, Inc., 9040 Briarwood Place, Baton Rouge, Louisiana 70809. LOCATION OF WORK: Within the Lake Pontchartrain Basin, in Amite River hydrologic unit (HUC 08070202). Beginning at the intersection of Louisiana Highway 16 and Cook raod, near Denham Springs, Louisiana, in Livingston Parish. CHARACTER OF WORK: The applicant has requested authorization to clear, grade, and fill an area to allow for the widening of Cook Road, construction of a new bridge over Grey's Creek, and construction of a turnaround at the intersection of Cook Road and LA-16. The proposed bridge will consist of an 84' x 140' slab span, pile-supported bridge. The new bridge and widening of Cook Road will result in impacts to 2.5 acres of jurisdictional wetlands and 1.3 acres of other waters. For these impacts, the applicant has agreed to purchase wetland credits from a Corps approved bank located within the watershed of impact. The newly improved Cook Road will tie into Juban Development, which was

authorized by permit number MVN 2005-4490 CZ. The Juban development permit authorized a road extending throughout the property and ending aligned with Cook Road. This road is in the process of being relinquished from the permit from Juban Development and transferred to Livingston Parish. The road has been mostly constructed in conjunction with Juban Development. However, the portion along the western boundary of the site has yet to be constructed. Livingston Parish is now proposing to modify the unconstructed portion of the authorized road to include six 8' x 7' x 124' concrete box culverts and fill at the crossing of the unnamed waterway. All wetland impacts within the boundary of the original authorization have been mitigated for. No additional wetland impacts will occur as a result of this modification. Thus, no additional mitigation will be assessed for the modification of the previously permitted road. The applicant has stated that the project has been designed to avoid and minimize direct and secondary adverse impacts to the maximum extent practicable. Any further reduction was deemed impracticable. During construction, best management practices (BMP's) will be implemented to prevent impacts to adjacent properties. The comment period for the Department of the Army Permit and the Louisiana Department of Environmental Quality WQC will close 20 days from the date of this joint public notice. Written comments, including suggestions for modifications or objections to the proposed work, stating reasons thereof, are being solicited from anyone having interest in this permit and/or this WQC request and must be mailed, so as to be received before or by the last day of the comment period. Letters concerning the Corps of Engineers permit application must reference the applicant's name and the Permit Application Number, and be mailed to the Corps of Engineers at the address above, ATTENTION: REGULATORY BRANCH. The application for this proposed project is on file with the Louisiana Department of Environmental Quality and may be examined weekdays between 8:00 a.m. and 4:30 p.m. Copies may be obtained upon payment of costs of reproduction. Individuals or parties may request an extension of time in which to comment on the proposed work by writing or e-mailing the Corps of Engineers Project Manager listed above. Any request must be specific and substantively supportive of the requested extension, and received by this office prior to the end of the initial comment period. The Section Chief will review the request and the requestor will be promptly notified of the decision to grant or deny the request. If granted, the time extension will be continuous to the initial comment period and, inclusive of the initial comment period, will not exceed a total of 30 calendar days. Letters concerning the Water Quality Certification must reference the applicant's name and the WQC Application number and be mailed to the Louisiana Department of Environmental Quality at the address above. Corps of Engineers Permit Criteria The decision whether to issue a permit will be based on an evaluation of the probable impacts, including cumulative impacts of the proposed activity on the public

interest. That decision will reflect the national concern for both protection and utilization of important resources. The benefit which reasonably may be expected to accrue from the proposal must be balanced against its reasonably foreseeable detriments. All factors which may be relevant to the proposal will be considered including the cumulative effects thereof; among those are conservation, economics, aesthetics, general environmental concerns, wetlands, historic properties, fish and wildlife values, flood hazards, floodplain values, land use, navigation, shoreline erosion and accretion, recreation, water supply and conservation, water quality, energy needs, safety, food and fiber production, mineral needs, considerations of property ownership and, in general, the needs and welfare of the people. The U.S. Army Corps of Engineers is soliciting comments from the public, federal, state, and local agencies and officials, Indian Tribes, and other interested parties in order to consider and evaluate the impacts of this proposed activity. Any comments received will be considered by the U.S. Army Corps of Engineers to determine whether to make, modify, condition, or deny a permit for this proposal. To make this decision, comments are used to assess impacts on endangered species, historic properties, water quality, general environmental effects, and other public interest factors listed above. Comments are used in the preparation of an Environmental Assessment and/or an Environmental Impact Statement pursuant to the National Environmental Policy Act. Comments are also used to determine the need for a public hearing and to determine the overall public interest of the proposed activity. The New Orleans District is unaware of properties listed on the National Register of Historic Places near the proposed work. The possibility exists that the proposed work may damage or destroy presently unknown archeological, scientific, prehistorical, historical sites, or data. Copies of this notice are being sent to the State Archeologist and State Historic Preservation Officer. Our initial finding is that the proposed work would not affect any species, nor affect any habitat designated as critical to the survival and recovery of such species, listed as endangered by the U.S. Department of Commerce. The New Orleans District has determined that the proposed project is located in waters known to be utilized by the west Indian manatee (Trichechus manatus) and determined that the proposed activity is not likely to adversely affect the species. This determination is based on the Standard Local Operating Procedure for Endangered Species of Louisiana (SLOPES), dated October 22, 2014, between the U.S. Army Corps of Engineers and U.S. Fish and Wildlife Service, Ecological Services Office. This notice initiates the Essential Fish Habitat (EFH) consultation requirements of the Magnuson-Stevens Fishery Conservation and Management Act. The applicant's proposal would result in the destruction or alteration of n/a acres of EFH utilized by various life stages of red drum and penaeid shrimp. Our initial determination is that the proposed action would not have a substantial adverse impact on EFH or federally managed fisheries in the Gulf of Mexico. Our final determination relative to project impacts and the need for mitigation measures is subject to review by and coordination

with the National Marine Fisheries Service. If the proposed work involves deposits of dredged or fill material into navigable waters, the evaluation of the probable impacts will include the application of guidelines established by the Administrator of the Environmental Protection Agency. Also, a certification that the proposed activity will not violate applicable water quality standards will be required from the Department of Environmental Quality, Office of Environmental Services, before a permit is issued. Any person may request, in writing, within the comment period specified in this notice, that a public hearing be held to consider this application. Requests for public hearings shall state, with particularity, the reasons for holding a public hearing. You are requested to communicate the information contained in this notice to any other parties whom you deem likely to have interest in the matter. You are requested to communicate the information contained in this notice to any other parties whom you deem likely to have interest in the matter.

John M. Herman Chief, Central Evaluation Section Regulatory Branch Enclosure

JUBAN RD.

US 190

PROJECT SITE

US 190

12 ROAD

WAX

ROA

LATTE

ST DE FORE

D

COOK ROAD

GRAPHIC SCALE

AREA SUMMARY SECTION 37 T-7-S, R-3-E LAT: 30°27'45" LONG: 90°55'58" DENHAM SPRINGS, LOUISIANA

0

5000'

10000'

SCALE: 1" = 5000'

COOK RD. VICINTY MAP LIVINGSTON PARISH

DRAWN: APPROVED:

DRAWING:

MNM GF

DATE:

1

07/2017

R:\2003\83145 - Cook Road\Cad - (Corps Permit)\Production Plan\83145 - Overall Proposed 1a.dwg

PHASE 1 1801.03 FEET = ROADWAY EXPANSION (TOTAL PROJECT) 3906.82 FEET = EXISTING ROADWAY TO BE WIDENED 1876.02 FEET = ROADWAY IN JURISDICTIONAL WATERS 589.26 FEET = ROADWAY IN WETLANDS

LIMITS OF CONSTRUCTION OTHER WATERS OF THE U.S. HERBACEOUS WETLANDS

PHASE 2 2683.51 FEET = ROADWAY EXPANSION 15.71 FEET = ROADWAY CROSSING JURISDICTIONAL WATERS

ROADWAY INCLUDED IN 404 PERMIT

COOK RD. OVERALL PROPOSED SITE LIVINGSTON PARISH

AER JPO

07/2017

2

GRAY'S CREEK

EXISTING ROAD (2-LANE)

EXISTING ROAD (2-LANE)

LIMITS OF CONSTRUCTION

LEGEND

GRAPHIC SCALE

LIMITS OF CONSTRUCTION OTHER WATERS OF THE U.S. DATA POINTS HERBACEOUS WETLANDS SECTION: 37 T-7-S, R-3-E

LATITUDE

COOK RD. EXISTING SITE MAP PHASE 1 LIVINGSTON PARISH

3

SEE INSET B

SEE INSET A

PROPOSED ROAD (4-LANE)

GRAY'S CREEK LIMITS OF CONSTRUCTION

PROPOSED 113' X 180' 7 SPAN BRIDGE

LEGEND

GRAPHIC SCALE PHASE 1 1801.03 FEET = ROADWAY EXPANSION (TOTAL PROJECT) 3906.82 FEET = EXISTING ROADWAY TO BE WIDENED 1876.02 FEET = ROADWAY IN JURISDICTIONAL WATERS 589.26 FEET = ROADWAY IN WETLANDS

LIMITS OF CONSTRUCTION OTHER WATERS OF THE U.S. DATA POINTS HERBACEOUS WETLANDS SECTION: 37 T-7-S, R-3-E

LATITUDE

COOK RD. PROPOSED SITE MAP PHASE 1 LIVINGSTON PARISH

4

EXISTING ROAD (2-LANE)

LIMITS OF CONSTRUCTION

LEGEND

GRAPHIC SCALE

LIMITS OF CONSTRUCTION OTHER WATERS OF THE U.S. DATA POINTS HERBACEOUS WETLANDS LATITUDE

SECTION: 37 T-7-S, R-3-E

COOK RD. EXISTING INSET A

5

GRAYS CREEK AREA: 0.32 ACRES FILL VOLUME: 102 C.Y.

OTHER WATERS AREA: 0.31 ACRES FILL VOLUME: 968 C.Y.

C

A

COOK RD.

WETLANDS AREA: 0.96 ACRES FILL VOLUME: 3652 C.Y.

B B

3 C

A

LIMITS OF CONSTRUCTION

PROPOSED ROAD (4-LANE)

PROPOSED BRIDGE

LEGEND

GRAPHIC SCALE

AREA SUMMARY INSET A 406.65 LINEAR FEET = ROADWAY IN OTHER WATERS 197.37 LINEAR FEET = ROADWAY IN WETLANDS 129.37 LINEAR FEET = ROADWAY IN GRAYS CREEK

LIMITS OF CONSTRUCTION 0

200'

400'

OTHER WATERS OF THE U.S. DATA POINTS

SCALE: 1" = 200' LATITUDE

HERBACEOUS WETLANDS SECTION: 37 T-7-S, R-3-E

COOK RD. PROPOSED INSET A LIVINGSTON PARISH

PROPOSED ROAD

DRAWN: APPROVED:

DRAWING:

MNM GF

DATE:

6

07/2017

FOR ESTIMATED FILL CALCULATIONS WITHIN WETLANDS AND OTHER WATERS, SEE TABLE ON SHEET 2.

PROPOSED PROJECT

65.0'

70.0'

RIGHT-OF-WAY

RIGHT-OF-WAY

LIMITS OF CONSTRUCTION

LIMITS OF CONSTRUCTION

32.5'

LIMITS OF

32.5'

LIMITS OF

HYDROSEEDING

HYDROSEEDING PROPOSED FINISH GRADE

EXISTING GRADE

SUBSURFACE DRAINAGE (TYP.)

OTHER WATERS OF THE U.S.

NON-WETLANDS

NON-WETLANDS

32.50'

PROPOSED SECTION A-A N.T.S.

LEGEND

AREA SUMMARY

PROPOSED COMPACTED LIME TREATMENT BASE (10" THICK)

SECTION 37 T-7-S, R-3-E LAT: 30°27'45" LONG: 90°55'58"

PROPOSED SELECT FILL (THICKNESS VARIES FROM 1.0' TO 2.5') PROPOSED P.C.C. PAVEMENT (8" THICK)

COOK RD. PROPOSED CROSS SECTION INSET A LIVINGSTON PARISH

DRAWN: APPROVED:

DRAWING:

MNM GF

DATE:

7

07/2017

FOR ESTIMATED FILL CALCULATIONS WITHIN WETLANDS AND OTHER WATERS, SEE TABLE ON SHEET 2. WETLANDS

OTHER WATERS OF THE U.S.

WETLANDS

112.0'

180.0 20.0'

20.0'

20.0'

40.0' CONC. APP. SLAB (TYP.)

20.0'

20.0'

3:1

20.0'

20.0'

20.0'

20.0'

3:1

PROPOSED FINISHED GRADE

EXISTING GRADE 55# RIP RAP (18" THICK) (70' X 100')

(40) 16" P.C.C. SQUARE PILES (TYP.) 55# RIP RAP (18" THICK) (70' X 100')

CONCRETE PILE CAP (TYP.)

PROPOSED 113' X 180' SLAB SPAN BRIDGE

PROPOSED SECTION B-B N.T.S.

LEGEND

AREA SUMMARY

PROPOSED CUT TOTAL (THICKNESS VARIES FROM 0.0' TO 12.8') = 3800 C.Y. PROPOSED 55# RIP RAP (18" THICK) TOTAL = 1800 C.Y.

SECTION 37 T-7-S, R-3-E LAT: 30°27'45" LONG: 90°55'58"

PROPOSED P.C.C. PAVEMENT (8" THICK) PROPOSED SELECT FILL (THICKNESS VARIES FROM 2.5' TO 5.0' )

COOK RD. PROPOSED CROSS SECTION INSET A LIVINGSTON PARISH

DRAWN: APPROVED:

DRAWING:

MNM GF

DATE:

8

07/2017

FOR ESTIMATED FILL CALCULATIONS WITHIN WETLANDS AND OTHER WATERS, SEE TABLE ON SHEET 2.

PROPOSED PROJECT

LIMITS OF CONSTRUCTION

65.0'

70.0'

RIGHT-OF-WAY

RIGHT-OF-WAY

32.5'

LIMITS OF

32.5'

HYDROSEEDING

LIMITS OF CONSTRUCTION

LIMITS OF HYDROSEEDING

PROPOSED FINISH GRADE

EXISTING GRADE SUBSURFACE DRAINAGE (TYP.)

WETLANDS 149.8'

PROPOSED SECTION C-C N.T.S.

LEGEND

AREA SUMMARY

PROPOSED COMPACTED LIME TREATMENT BASE (10" THICK)

SECTION 37 T-7-S, R-3-E LAT: 30°27'45" LONG: 90°55'58"

PROPOSED SELECT FILL TOTAL (THICKNESS VARIES FROM 2.0' TO 4.2') = 1370 C.Y. (WETLANDS) PROPOSED P.C.C. PAVEMENT (8" THICK)

COOK RD. PROPOSED CROSS SECTION INSET A LIVINGSTON PARISH

DRAWN: APPROVED:

DRAWING:

MNM GF

DATE:

9

07/2017

PHASE 1

PHASE 2

1

2

LIMITS OF CONSTRUCTION

ADJACENT PROPERTY

LEGEND

GRAPHIC SCALE

LIMITS OF CONSTRUCTION 0

200'

400'

OTHER WATERS OF THE U.S. DATA POINTS

SCALE: 1" = 200' LATITUDE

HERBACEOUS WETLANDS SECTION: 37 T-7-S, R-3-E

COOK RD. EXISTING INSET B LIVINGSTON PARISH

DRAWN: APPROVED:

DRAWING:

MNM GF

DATE:

10

07/2017

WETLANDS AREA: 0.38 ACRES FILL VOLUME: 1461 C.Y.

OTHER WATERS AREA: 0.95 ACRES FILL VOLUME: 1130 C.Y.

WETLANDS AREA: 0.64 ACRES FILL VOLUME: 2460 C.Y.

PHASE 1

PHASE 2

F

E

COOK ROAD D

D

1

2 F

E

WETANDS AREA: 0.55 ACRES FILL VOLUME: 2152 C.Y.

PROPOSED ROAD (4-LANE)

LIMITS OF CONSTRUCTION

ADJACENT PROPERTY

PROPOSED 30" X 120' CULVERT TO MAINTAIN EXISTING DRAINAGE OTHER WATERS AREA: 0.57 ACRES FILL VOLUME: 1292 C.Y.

LEGEND

GRAPHIC SCALE

AREA SUMMARY INSET B 1469.37 LINEAR FEET = ROADWAY IN OTHER WATERS 391.89 LINEAR FEET = ROADWAY IN WETLANDS

LIMITS OF CONSTRUCTION 0

200'

400'

OTHER WATERS OF THE U.S. DATA POINTS

SCALE: 1" = 200' LATITUDE

HERBACEOUS WETLANDS SECTION: 37 T-7-S, R-3-E

COOK RD. PROPOSED INSET B LIVINGSTON PARISH

PROPOSED ROAD

DRAWN: APPROVED:

FIGURE:

MNM GF

DATE:

11

07/2017

FOR ESTIMATED FILL CALCULATIONS WITHIN WETLANDS AND OTHER WATERS, SEE TABLE ON SHEET 2.

WETLANDS

SELECT FILL

OTHER WATERS OF THE U.S

WETLANDS

74.2'

82.9'

8" P.C.C. PAVEMENT

PROPOSED 30" X 120' CULVERT

10" COMPACTED LIME TREATMENT BASE

NONWETLANDS

EXISTING GRADE

PROPOSED SECTION D-D N.T.S.

LEGEND

AREA SUMMARY

PROPOSED COMPACTED LIME TREATMENT BASE

SECTION 37 T-7-S, R-3-E LAT: 30°27'45" LONG: 90°55'58"

PROPOSED SELECT FILL TOTAL (THICKNESS VARIES FROM 0.4' TO 4.0') = 1370 C.Y. (WETLANDS) PROPOSED 8" P.C.C. PAVEMENT

COOK RD. PROPOSED CROSS SECTION INSET B LIVINGSTON PARISH

DRAWN: APPROVED:

DRAWING:

MNM GF

DATE:

12

07/2017

FOR ESTIMATED FILL CALCULATIONS WITHIN WETLANDS AND OTHER WATERS, SEE TABLE ON SHEET 2.

PROPOSED PROJECT

LIMITS OF CONSTRUCTION

65.0'

70.0'

RIGHT-OF-WAY

RIGHT-OF-WAY

LIMITS OF

32.5'

32.5'

HYDROSEEDING

LIMITS OF CONSTRUCTION

LIMITS OF HYDROSEEDING

PROPOSED FINISH GRADE

3:1

3:1

EXISTING GRADE

SUBSURFACE DRAINAGE (TYP.)

NON-WETLANDS

WETLANDS

OTHER WATERS OF THE U.S.

97.6'

23.1'

PROPOSED SECTION E-E N.T.S.

LEGEND

AREA SUMMARY

PROPOSED COMPACTED LIME TREATMENT BASE (10" THICK)

SECTION 37 T-7-S, R-3-E LAT: 30°27'45" LONG: 90°55'58"

PROPOSED SELECT FILL TOTAL (THICKNESS VARIES FROM 0.0' TO 1.2') = 1370 C.Y. (WETLANDS) PROPOSED P.C.C. PAVEMENT (8" THICK)

COOK RD. PROPOSED CROSS SECTION INSET B LIVINGSTON PARISH

DRAWN: APPROVED:

DRAWING:

MNM GF

DATE:

13

07/2017

FOR ESTIMATED FILL CALCULATIONS WITHIN WETLANDS AND OTHER WATERS, SEE TABLE ON SHEET 2.

PROPOSED PROJECT

LIMITS OF CONSTRUCTION

65.0'

70.0'

RIGHT-OF-WAY

RIGHT-OF-WAY

LIMITS OF

32.5'

32.5'

HYDROSEEDING

LIMITS OF CONSTRUCTION

LIMITS OF HYDROSEEDING

PROPOSED FINISH GRADE

3:1

3:1

EXISTING GRADE SUBSURFACE DRAINAGE (TYP.)

OTHER WATERS OF THE U.S.

NON-WETLANDS

21.4'

PROPOSED SECTION F-F N.T.S.

LEGEND

AREA SUMMARY

PROPOSED COMPACTED LIME TREATMENT BASE (10" THICK)

SECTION 37 T-7-S, R-3-E LAT: 30°27'45" LONG: 90°55'58"

PROPOSED SELECT FILL (THICKNESS VARIES FROM 0.0' TO 1.9') PROPOSED P.C.C. PAVEMENT (8" THICK)

COOK RD. PROPOSED CROSS SECTION INSET B LIVINGSTON PARISH

DRAWN: APPROVED:

DRAWING:

MNM GF

DATE:

14

07/2017

LEGEND

GRAPHIC SCALE

LIMITS OF CONSTRUCTION OTHER WATERS OF THE U.S. HERBACEOUS WETLANDS SECTION: 37 T-7-S, R-3-E

LATITUDE

COOK RD. EXISTING SITE MAP PHASE 2 LIVINGSTON PARISH

AER JPO

07/2017

15

SEE INSET C

PROPOSED (6) 8' X 7' X 124' LONG PRECAST CONCRETE BOX CULVERTS

LEGEND

GRAPHIC SCALE PHASE 2 2683.51 LINEAR FEET = ROADWAY EXPANSION 15.71 LINEAR FEET = ROADWAY CROSSING OTHER WATERS

LIMITS OF CONSTRUCTION OTHER WATERS OF THE U.S. WETLANDS SECTION: 37 T-7-S, R-3-E

LATITUDE

COOK RD. PROPOSED SITE MAP PHASE 2 LIVINGSTON PARISH

AER JPO

07/2017

16

LEGEND

GRAPHIC SCALE

LIMITS OF CONSTRUCTION OTHER WATERS OF THE U.S.

SECTION: 37 T-7-S, R-3-E

LATITUDE

COOK RD. EXISTING INSET C LIVINGSTON PARISH

AER JPO

07/2017

17

PROPOSED ROAD (4-LANE)

G

G

PROPOSED (6) 8' X 7' X 124' LONG PRECAST CONCRETE BOX CULVERTS

LEGEND

GRAPHIC SCALE INSET C 15.71 FEET = ROADWAY CROSSING OTHER WATERS

LIMITS OF CONSTRUCTION OTHER WATERS OF THE U.S. PROPOSED ROAD SECTION: 37 T-7-S, R-3-E

LATITUDE

COOK RD. PROPOSED INSET C LIVINGSTON PARISH

AER JPO

07/2017

18

NON-WETLANDS

OTHER WATERS

NON-WETLANDS

16.2' PROPOSED PROFILE GRADE

LIMITS OF BACKFILL

56.76'

LIMITS OF BACKFILL

EXISTING GRADE

LIN E

TOP OF BANK

ED

OS

EX 2:1 CA VA T

IO N

OP PR PR

ON

OP OS E

D

1 ATI V CA

2:

EX

E

LIN PROPOSED (6) 8' X 7' X 124' LONG PRECAST CONCRETE BOX CULVERTS

SLOPE ON BEDDING EXCAVATION NOT NECESSARY (LESS THAN 4')

BEDDING MATERIAL (36" DEPTH)

PROPOSED SECTION G-G N.T.S.

LEGEND

AREA SUMMARY

PROPOSED BEDDING MATERIAL (36" THICK) = 865 C.Y.

SECTION 37 T-7-S, R-3-E LAT: 30°27'45" LONG: 90°55'58"

PROPOSED SELECT FILL (THICKNESS VARIES FROM 3.9' TO 4.1') = 515 C.Y. IN OTHER WATERS PROPOSED CUT TOTAL (THICKNESS VARIES FROM 3.2' TO 10.3') = 3800 C.Y.

COOK RD. PROPOSED CROSS SECTION INSERT C LIVINGSTON PARISH

DRAWN: APPROVED:

DRAWING:

AER JPO

DATE:

19

07/2017

0

1000'

2000'

SCALE: 1" = 1000' ROW REMOVED FROM PREVIOUS 404 PERMIT NO. MVN-2005-4490-CZ TO BE INCLUDED IN MVN-2015-01559-CO (THIS PERMIT)

H H

LEGEND

AREA SUMMARY 14.36 ACRES = AREAS OF ROAD REMOVED

ROW TO BE REMOVED FROM PREVIOUS 404 PERMIT NO. MVN-2005-4490-CZ TO BE INCLUDED IN MVN-2015-01559-CO (THIS PERMIT)

2.75 ACRES = AREAS OF WETLANDS IMPACTED BY ROAD 4772.36 = LINEAR FEET OF ROAD REMOVED

WETLANDS TO BE REMOVED FROM PREVIOUS 404 PERMIT NO. MVN-2005-4490-CZ TO BE INCLUDED IN MVN-2015-01559-CO (THIS PERMIT)

929.44 = LINEAR FEET OF OF WETLANDS IMPACTED BY ROAD

COOK RD. 404 PERMIT LIVINGSTON PARISH

DRAWN: APPROVED:

DRAWING:

MJM JPO

DATE:

20

07/2017

PROPOSED PROJECT

60.0'

60.0'

RIGHT-OF-WAY

RIGHT-OF-WAY

32.5'

32.5'

EXISTING FINISH GRADE

EXISTING GROUND

EXISTING GROUND

3:1

3:1

SUBSURFACE DRAINAGE (TYP.)

EXISTING SECTION H-H N.T.S.

LEGEND

AREA SUMMARY EXISTING ROAD BASE EXISTING P.C.C. PAVEMENT

SECTION 37 T-7-S, R-3-E LAT: 30°27'45" LONG: 90°55'58"

EXISTING JUBAN CROSS SECTION LIVINGSTON PARISH

DRAWN: APPROVED:

DRAWING:

MJM JPO

DATE:

21

07/2017

Rough impact

We use the fields in this section to decide whether to conduct an in-depth review.

Permit Manager

Dates

Identity numbers

Permits, certifications, and locations related to this particular notice

History of edits

Data are available as CSV download in the following schemas