TIMBALIER ISLAND AND TRINITY EAST ISLANDS RESTORATION PROJECT IN TERREBONNE PARISH

NAME OF APPLICANT: Coastal Protection and Restoration Authority of Louisiana (CPRA), Attn: Justin Merrifield, Post Office Box 44027, Baton Rouge, Louisiana 70804. LOCATION OF WORK: Located in Lake Pelto and Terrebonne Bay, south of Cocodrie, Louisiana, located in Terrebonne Parish, as shown on the enclosed drawings (Latitude 29.06678 N Longitude -90.48855 W). This project is located in Terrebonne Basin (West Central Louisiana Coastal HUC 08090302). CHARACTER OF WORK: The applicant is requesting a Department of the Army permit authorization for the Restoration of Timbalier Island and Trinity East Islands through beach and dune fill placement utilizing offshore sand material located in federal waters. The project is a part of the Terrebonne Basin Barrier Island and Beach Nourishment Restoration Project (TE-143) located south of Cocodrie, Louisiana, in Terrebonne Parish. The project has been designed to restore the geomorphic and ecologic form and function of the barrier island features at Timbalier Island and Trinity East Island to provide and protect critical habitats. The project proposes to add sand material in areas most susceptible to breaching and provide benefits through the restoration and sustaining of important coastal habitats such as nesting habitat for numerous shorebird species. The applicant has stated that they have designed this project to be synergistic with currently implemented and future restoration projects. Approximately 16,130,359 cubic yards of native waterbottom material would be dredged (hydraulic cutterhead dredge and hopper dredge) and placed as fill for barrier island, dune, and marsh platform restoration/creation activities. Approximately 981 acres of beach, dune, and marsh habitat are proposed to be created as a result of the fill placement. Approximately 921 acres of waterbottoms would be impacted through dredging activities at the borrow sites. Approximately 91 acres of wetlands would be impacted as a result of the fill placement. Created beach and dune habitat and marsh platform habitat are proposed to be replanted with appropriate native ecospecies. The applicant has claimed that the project has been designed to avoid and minimize direct and secondary adverse wetland impacts to the maximum extent practicable. The applicant is proposing that the project derived benefits and habitat creation would outweigh any detrimental impacts to wetland areas as a result of project implementation. Compensatory mitigation requirements are not anticipated.

JOINT PUBLIC NOTICE May 21, 2018 United States Army Corps of Engineers New Orleans District Regulatory Branch 7400 Leake Avenue New Orleans, Louisiana 70118

State of Louisiana Department of Environmental Quality Water Permits Division Post Office Box 4313 Baton Rouge, Louisiana 70821-4313

(504) 862-1217 Project Manager Kenny Blanke Kenneth.G.Blanke@usace.army.mil MVN 2018-0532-CQ

(225) 219-3225 Project Manager Ms. Elizabeth Hill WQC Application Number WQC 180517-03

Interested parties are hereby notified that a permit application has been received by the New Orleans District of the U.S. Army Corps of Engineers pursuant to: [X] Section 10 of the Rivers and Harbors Act of March 3, 1899 (30 Stat. 1151; 33 USC 403); and/or [X] Section 404 of the Clean Water Act (86 Stat. 816; 33 USC 1344). Application has also been made to the Louisiana Department of Environmental Quality, Office of Environmental Services, for a Water Quality Certification (WQC) in accordance with statutory authority contained in LRS30:2074 A(3), and provisions of Section 401 of the Clean Water Act (P.L.95-17). TIMBALIER ISLAND AND TRINITY EAST ISLANDS RESTORATION PROJECT IN_TERREBONNE PARISH NAME OF APPLICANT: Coastal Protection and Restoration Authority of Louisiana (CPRA), Attn: Justin Merrifield, Post Office Box 44027, Baton Rouge, Louisiana 70804. LOCATION OF WORK: Located in Lake Pelto and Terrebonne Bay, south of Cocodrie, Louisiana, located in Terrebonne Parish, as shown on the enclosed drawings (Latitude 29.06678 N Longitude -90.48855 W). This project is located in Terrebonne Basin (West Central Louisiana Coastal HUC 08090302). CHARACTER OF WORK: The applicant is requesting a Department of the Army permit authorization for the Restoration of Timbalier Island and Trinity East Islands through beach and dune fill placement utilizing offshore sand material located in federal waters. The project is a part of the Terrebonne Basin Barrier Island and Beach Nourishment Restoration Project (TE143) located south of Cocodrie, Louisiana, in Terrebonne Parish. The project has been designed to restore the geomorphic and ecologic form and function of the barrier island features at Timbalier Island and Trinity East Island to provide and protect critical habitats. The project proposes to add sand material in areas most susceptible to breaching and provide benefits through the restoration and sustaining of important coastal habitats such as nesting habitat for numerous shorebird species. The applicant has stated that they have designed this project to be synergistic with currently implemented and future restoration projects. Approximately 16,130,359 cubic yards of native waterbottom material would be dredged (hydraulic cutterhead dredge and hopper dredge) and placed as fill for barrier island, dune, and marsh platform restoration/creation activities. Approximately 981 acres of beach, dune, and marsh habitat are proposed to be created as a result of the fill placement. Approximately 921 acres of

waterbottoms would be impacted through dredging activities at the borrow sites. Approximately 91 acres of wetlands would be impacted as a result of the fill placement. Created beach and dune habitat and marsh platform habitat are proposed to be replanted with appropriate native ecospecies. The applicant has claimed that the project has been designed to avoid and minimize direct and secondary adverse wetland impacts to the maximum extent practicable. The applicant is proposing that the project derived benefits and habitat creation would outweigh any detrimental impacts to wetland areas as a result of project implementation. Compensatory mitigation requirements are not anticipated. The comment period for the Department of Army Permit and the Louisiana Department of Environmental Quality will close in 20 days from the date of this joint public notice. Written comments, including suggestions for modifications or objections to the proposed work, stating reasons thereof, are being solicited from anyone having interest in this permit and/or this WQC request and must be mailed so as to be received before or by the last day of the comment period. Letters concerning the Corps of Engineers permit application must reference the applicant's name and the Permit Application Number, and be mailed to the Corps of Engineers at the address above, ATTENTION: REGULATORY BRANCH. Similar letters concerning the Water Quality Certification must reference the applicant's name and the WQC application number and be mailed to the Louisiana Department of Environmental Quality at the address above. Individuals or parties may request an extension of time in which to comment on the proposed work by writing or e-mailing the Corps of Engineers Project Manager listed above. Any request must be specific and substantively supportive of the requested extension, and received by this office prior to the end of the initial comment period. The Section Chief will review the request and the requestor will be promptly notified of the decision to grant or deny the request. If granted, the time extension will be continuous to the initial comment period and, inclusive of the initial comment period, will not exceed a total of 30 calendar days. The application for this proposed project is on file with the Louisiana Department of Environmental Quality and may be examined during weekdays between 8:00 a.m. and 4:30 p.m. Copies may be obtained upon payment of costs of reproduction. Bureau of Ocean Energy Management (BOEM): A lease for use of Federal sand resources from South Pelto Area Lease Blocks 12 and 13 is required from BOEM. If you have any questions concerning the lease application, you may contact Michael Miner at Michael.Miner@boem.gov (504)736-2700. Please furnish BOEM a copy of all public notice comments. Copies can be mailed to Greg Kozlowski, Deputy Regional Supervisor, Office of Environment, Bureau of Ocean Energy Management, 1202 Elmwood Park Blvd., New Orleans, LA 70123. Note: The Bureau of Ocean Energy Management (BOEM) has sole regulatory authority over the use of Outer Continental Shelf (OCS) sand resources and conveyance on the OCS under the OCS Lands Act. The U.S. Army Corps of Engineers (Corps) requires a permit for all other aspects of the project, including dredging of any state water bottom areas, as well as conveyance and placement of sand resources. BOEM and the Corps are working collaboratively to ensure effective implementation of the required National Environment Policy Act (NEPA) process, the required Endangered Species Act (ESA) Section 7 consultations, the Magnuson-Stevens Fishery and Conservation Management Act Essential Fish Habitat consultation (Section 305), the National Historic Preservation Act Section 106 process, and the Coastal Zone Management Act Section 307 consistency determination. Corps of Engineers Permit Criteria The decision whether to issue a permit will be based on an evaluation of the probable impacts, including cumulative impacts of the proposed activity on the public interest. That decision will reflect the national concern for both protection and utilization of important

resources. The benefit which reasonably may be expected to accrue from the proposal must be balanced against its reasonably foreseeable detriments. All factors which may be relevant to the proposal will be considered including the cumulative effects thereof; among those are conservation, economics, aesthetics, general environmental concerns, wetlands, historic properties, fish and wildlife values, flood hazards, floodplain values, land use, navigation, shoreline erosion and accretion, recreation, water supply and conservation, water quality, energy needs, safety, food and fiber production, mineral needs, considerations of property ownership and, in general, the needs and welfare of the people. The US Army Corps of Engineers is soliciting comments from the public, federal, state, and local agencies and officials, Indian Tribes, and other interested parties in order to consider and evaluate the impacts of this proposed activity. Any comments received will be considered by the US Army Corps of Engineers to determine whether to make, modify, condition, or deny a permit for this proposal. To make this decision, comments are used to assess impacts on endangered species, historic properties, water quality, general environmental effects, and other public interest factors listed above. Comments are used in the preparation of an Environmental Assessment and/or an Environmental Impact Statement pursuant to the National Environmental Policy Act. Comments are also used to determine the need for a public hearing and to determine the overall public interest of the proposed activity. The New Orleans District is unaware of properties listed on the National Register of Historic Places near the proposed work. The possibility exists that the proposed work may damage or destroy presently unknown archeological, scientific, prehistorical, historical sites, or data. Copies of this notice are being sent to the State Archeologist and State Historic Preservation Officer. Our initial finding is that the proposed work would neither affect any species listed as endangered by the U.S. Departments of Interior or Commerce, nor affect any habitat designated as critical to the survival and recovery of any endangered species. Utilizing Standard Local Operating Procedure for Endangered Species in Louisiana (SLOPES), dated October 22, 2014, between the U.S. Army Corps of Engineers, New Orleans and U.S. Fish and Wildlife Service, Ecological Services Office, the Corps has determined that with the inclusion of special conditions, the proposed activity is not likely adversely affect the West Indian manatee (Trichechus manatus). This notice initiates the Essential Fish Habitat (EFH) consultation requirements of the Magnuson-Stevens Fishery Conservation and Management Act. The applicant's proposal would result in the destruction or alteration of 1,902 acres of EFH utilized by various life stages of red drum and penaeid shrimp. Our initial determination is that the proposed action would not have a substantial adverse impact on EFH or federally managed fisheries in the Gulf of Mexico. Our final determination relative to project impacts and the need for mitigation measures is subject to review by and coordination with the National Marine Fisheries Service. If the proposed work involves deposits of dredged or fill material into navigable waters, the evaluation of the probable impacts will include the application of guidelines established by the Administrator of the Environmental Protection Agency. Also, a certification that the proposed activity will not violate applicable water quality standards will be required from the Department of Environmental Quality, Office of Environmental Services, before a permit is issued. Any person may request, in writing, within the comment period specified in this notice, that a public hearing be held to consider this application. Requests for public hearings shall state, with particularity, the reasons for holding a public hearing. You are requested to communicate the information contained in this notice to any other parties whom you deem likely to have interest in the matter.

The applicant has certified that the proposed activity described in the application complies with and will be conducted in a manner that is consistent with the Louisiana Coastal Resources Program. The Department of the Army permit will not be issued unless the applicant received approval or a waiver of the Coastal Use Permit by the Department of Natural Resources.

for Enclosure

JOHN M. HERMAN Chief, Central Evaluation Section Regulatory Branch

STATE OF LOUISIANA COASTAL PROTECTION AND RESTORATION AUTHORITY

INDEX TO SHEETS SHEET NO. 1 2 3 4 5 6-7 8 9 10 11 12 13 - 14 15 16 17 18 - 19 20 21 - 22 23 24 - 25 26 27 - 28 29 30 31 32 33 - 36

TERREBONNE BASIN BARRIER ISLAND AND BEACH NOURISHMENT STATE PROJECT NO. TE-143 TERREBONNE PARISH, LOUISIANA PRELIMINARY

DESCRIPTION TITLE SHEET PROJECT OVERVIEW MAP GENERAL NOTES TIMBALIER ISLAND NOURISHMENT AREA PLAN VIEW TIMBALIER ISLAND NOURISHMENT TYPICAL SECTIONS TIMBALIER ISLAND ACCESS CHANNELS TIMBALIER ISLAND DOCK REMOVAL ACCESS CHANNEL TIMBALIER ISLAND DOCK REMOVAL DETAIL TRINITY-EAST ISLAND NOURISHMENT AREA PLAN VIEW TRINITY-EAST ISLAND NOURISHMENT TYPICAL SECTIONS TRINITY-EAST ISLAND UPLAND ACCESS CORRIDOR TRINITY-EAST ISLAND ACCESS CHANNELS TRINITY-EAST ISLAND DOCK REMOVAL ACCESS CHANNEL TRINITY-EAST ISLAND DOCK REMOVAL DETAIL SHIP SHOAL BORROW AREA PLAN VIEW SHIP SHOAL BORROW AREA TYPICAL SECTIONS SOUTH PELTO BORROW AREA PLAN VIEW SOUTH PELTO BORROW AREA TYPICAL SECTIONS TIMBALIER PUMP-OUT AREAS & CONVEYANCE CORRIDORS OVERVIEW TIMBALIER PUMP-OUT AREAS & CONVEYANCE CORRIDORS PLAN VIEW TRINITY-EAST PUMP-OUT AREAS & CONVEYANCE CORRIDORS OVERVIEW TRINITY-EAST PUMP-OUT AREAS & CONVEYANCE CORRIDORS PLAN VIEW OPTIONAL SEDIMENT PIPELINE CROSSING TYPICAL DETAILS SAND FENCING DETAILS TIMBALIER ISLAND VEGETATIVE PLANTING DETAILS TRINITY-EAST ISLAND VEGETATIVE PLANTING DETAILS ALIGNMENT AND COORDINATE TABLES

BY

DESCRIPTION

TIMBALIER ISLAND RESTORATION AREA

TRINITY-EAST ISLAND RESTORATION AREA

LAKE PELTO

TERREBONNE PARISH

CONVEYANCE CORRIDORS

STATE / FEDERAL WATER BOUNDARY TIMBALIER ISLAND PUMP OUT AREAS

TRINITY-EAST ISLAND PUMP OUT AREAS SOUTH PELTO BORROW AREAS

GULF OF MEXICO

SHIP SHOAL BORROW AREA

30,000'

15,000'

0'

30,000'

NOTES: 1. FOR PERMITTING PURPOSES ONLY. NOT TO BE USED FOR CONSTRUCTION. 2. RETAIN ENTIRE SET AS ONE, INDIVIDUAL SHEETS SHOULD NOT BE REMOVED.

60,000'

L J

DATE

COASTAL ENGINEERING CONSULTANTS, INC. PH: (225) 768-1982 8570 ANSELMO LANE BATON ROUGE, LA 70810

DRAWN BY: STEVE DARTEZ

TIMBALIER BAY

TERREBONNE BAY

DESIGNED BY: MICHAEL T. POFF, P.E. LICENSE NUMBER: 30048

LOUISIANA COASTAL PROTECTION AND RESTORATION AUTHORITY 150 TERRACE AVENUE BATON ROUGE, LA 70802

APPROVED BY: TRAVIS BYLAND, P.E.

TERREBONNE BASIN BARRIER ISLAND AND BEACH NOURISHMENT

TITLE SHEET

STATE PROJECT NUMBER: TE-143

DATE: APRIL 2018

FEDERAL PROJECT NUMBER:

SHEET 1 OF 36

CASSE-TETE ISLAND

TIMBALIER BAY 215,000 N

3,585,000 E

215,000 N

3,555,000 E

TIMBALIER ISLAND

CALUMET ISLAND

TRINITY-EAST ISLAND

LAKE PELTO

185,000 N

ST11 185,000 N

STATE / FEDERAL WATER BOUNDARY SP03 SP08

SP04 SP07

SP05 SP06

TRINITY-EAST ISLAND PUMP OUT AREAS

155,000 N

3,495,000 E

OCS LEASE BLOCK

ST18 ST19

ST33 ST34

SOUTH PELTO BORROW AREAS

155,000 N

ST32 ST35

155,000 N

ST31 ST36

LEGEND

ST30 ST37

BORROW AREA LIMITS 3,585,000 E

SP01 SP02 SP10 SP09

ST17

TIMBALIER ISLAND PUMP OUT AREAS

3,525,000 E

SS67 SS66 SS68 SS69

ST16

3,585,000 E

ST09 ST10

3,555,000 E

185,000 N

3,525,000 E

CONVEYANCE CORRIDORS

3,495,000 E

WHISKEY ISLAND

215,000 N

3,525,000 E

215,000 N

3,495,000 E

TERREBONNE BAY

ISLAND RESTORATION AREA 155,000 LIMITS N PUMP-OUT AREA LIMITS

SS91 SS90 SS92 SS93

SP11 SP12 SP20 SP19

SP13 SP14 SP18 SP17

SHIP SHOAL BORROW AREA 15,000'

7,500'

0'

BY

DESCRIPTION

15,000'

30,000'

DATE

GULF OF MEXICO ST51 ST52

COASTAL ENGINEERING CONSULTANTS, INC. PH: (225) 768-1982 8570 ANSELMO LANE BATON ROUGE, LA 70810

DRAWN BY: STEVE DARTEZ

CONVEYANCE CORRIDOR ALIGNMENTS

SP15 SP16

DESIGNED BY: MICHAEL T. POFF, P.E. LICENSE NUMBER: 30048

LOUISIANA COASTAL PROTECTION AND RESTORATION AUTHORITY 150 TERRACE AVENUE BATON ROUGE, LA 70802

APPROVED BY: TRAVIS BYLAND, P.E.

ST50 ST53

NOTES: 1. ALL COORDINATES ARE NAD83, PLANE, U.S. ST49 LOUISIANA STATE ST48 SURVEY FEET. ST54 ST55

TERREBONNE BASIN BARRIER ISLAND AND BEACH NOURISHMENT

PROJECT OVERVIEW MAP

STATE PROJECT NUMBER: TE-143

DATE: APRIL 2018

FEDERAL PROJECT NUMBER:

SHEET 2 OF 36

GENERAL NOTES: 1. 2. 3. 4. 5. 6. 7.

8. 9. 10. 11. 12.

13.

14. 15. 16. 17.

ANY EXCAVATED MATERIAL WILL BE, TO THE BEST OF KNOWLEDGE, FREE OF CONTAMINANTS AND/OR WILL BE DISPOSED OF IN AN APPROVED LANDFILL. THE CONTRACTOR SHALL BECOME FAMILIAR WITH THE SITE, CONSTRUCTION PLANS, AND CONTRACT DOCUMENTS AND SHALL CONDUCT WORK IN STRICT ACCORDANCE WITH ALL PERMITS AND APPROVALS OBTAINED FOR THIS PROJECT. THE CONTRACTOR SHALL NOTIFY THE ENGINEER OF ANY ERRORS OR DISCREPANCIES IN THE PLANS PRIOR TO BIDDING. AERIAL IMAGE REFERENCE: ©2018 MICROSOFT CORPORATION ©2018 DIGITAL GLOBE ©CNES (2018) DISTRIBUTION AIRBUS DS; BING. PROBABLE PIPELINES SHOWN ARE FROM LOUISIANA DEPARTMENT OF NATURAL RESOURCES, OFFICE OF COASTAL MANAGEMENT - 2010, BUREAU OF OCEAN ENERGY MANAGEMENT - 2007, AND OCEAN SURVEYS, INC. - 2011 & 2015. THE CONTRACTOR SHALL BE RESPONSIBLE FOR NOTIFYING PIPELINE AND UTILITY OPERATORS AT THE TIME OF CONSTRUCTION. ALL PIPELINES AND UNDERGROUND UTILITIES SHALL BE FIELD LOCATED AND MARKED. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CONTACTING LOUISIANA ONE CALL SYSTEM (1-800-272-3020) A MINIMUM OF 48 HOURS PRIOR TO THE COMMENCEMENT OF ANY EXCAVATION (DIGGING, DREDGING, JETTING, ETC.) OR DEMOLITION ACTIVITY. THE CONTRACTOR SHALL ALSO NOTIFY PIPELINE AND UTILITY OPERATORS 72 HOURS PRIOR TO ANY EXCAVATION. THE WATER BOTTOM SHALL NOT BE DISTURBED DURING ACCESS TO THE PROPOSED WORK LOCATION, OR BY THE AUTHORIZED ACTIVITIES WHETHER IT BE BY DREDGING, WHEEL WASHING , PROPWASHING, JETTING, MUCKING, PLOWING, BULL DOZING OR ANY MEANS OF MOVING BOTTOM MATERIAL, EXCEPT AS DEPICTED ON THE PERMIT SHEETS. POWERED VESSELS SHALL BE OPERATED SO AS NOT TO DISTURB THE WATER BOTTOM BY PROPELLER OR JET ACTION. ALL LOGS, STUMPS, AND OTHER DEBRIS UNEARTHED DURING DREDGING SHALL BE REMOVED TO AN APPROVED OFFSITE DISPOSAL AREA. THE CONTRACTOR MUST INSTALL AND MAINTAIN ANY SAFETY LIGHTS, SIGNS, AND SIGNALS PRESCRIBED BY THE U.S. COAST GUARD, THROUGH REGULATIONS OR OTHERWISE ON THE AUTHORIZED FACILITIES. ANY DAMAGE TO EXISTING U.S. COAST GUARD NAVIGATION AIDS OR PRIVATE NAVIGATION AIDS SHALL BE REPAIRED BY THE CONTRACTOR TO U.S. COAST GUARD STANDARDS AT THE EXPENSE OF THE CONTRACTOR. PIPELINES IN OPEN WATER AND/OR NAVIGABLE WATERS SHALL BE MARKED WITH BUOYS BY THE CONTRACTOR IN ACCORDANCE WITH TECHNICAL SPECIFICATIONS. THE CONTRACTOR SHALL MAINTAIN BUOYS DURING CONSTRUCTION OR HAVE ADEQUATE NAVIGATIONAL EQUIPMENT ON THE DREDGE TO AVOID DREDGING IN RESTRICTED AREAS. THE PROPOSED PROJECT AND ANY FUTURE MAINTENANCE WORK INVOLVING THE USE OF FLOATING CONSTRUCTION EQUIPMENT (BARGE MOUNTED CRANES, BARGE MOUNTED PILE DRIVING EQUIPMENT, FLOATING DREDGE EQUIPMENT, DREDGE DISCHARGE PIPELINES, ETC.) IN FEDERAL WATERS, SHALL NOTIFY THE U.S. COAST GUARD SO THAT A NOTICE TO MARINERS, IF REQUIRED, MAY BE PREPARED. NOTIFICATION, WITH A COPY OF THE PERMIT APPROVAL AND DRAWINGS, SHALL BE MAILED TO THE U.S. COAST GUARD, SECTOR NEW ORLEANS COMMAND CENTER, 201 HAMMOND HIGHWAY, METAIRIE, LOUISIANA 70005, 30 DAYS BEFORE COMMENCEMENT OF WORK. THE OFFSHORE WORK AREAS SHALL CONSIST OF THE BORROW AREAS AND CONVEYANCE CORRIDORS. THE INSHORE WORK AREA IS DEFINED BY A 150' OFFSET FROM THE OUTER LIMITS OF THE ACCESS CHANNELS, TEMPORARY SIDECAST DISPOSAL AREAS, AND THE GULF TOE OF THE BEACH FILL TEMPLATE. THE CONTRACTOR SHALL BE REQUIRED TO CONFINE HIS/HER PLANT, EQUIPMENT, AND OPERATIONS OF PERSONNEL WITHIN THE LIMITS OF THE WORK AREA, AREAS PERMITTED BY LAW, ORDINANCES, PERMITS, AND THE REQUIREMENTS OF THE CONTRACT DOCUMENTS.THE CONTRACTOR SHALL NOT UNREASONABLY ENCUMBER THE PREMISES WITH PLANT OR EQUIPMENT. THE CONTRACTOR SHALL FOLLOW CONVEYANCE CORRIDORS, ACCESS CHANNELS, UPLAND ACCESS CORRIDORS, AND / OR FILL TEMPLATES, AND SHALL NOT, AT ANY TIME, TRAVEL ON EXISTING MARSH OR VEGETATED WETLANDS UNLESS SPECIFIED IN THE PERMIT OR THROUGH WRITTEN DIRECTION FROM ENGINEER. THE CONTRACTOR SHALL WORK COOPERATIVELY WITH THE OWNER TO ADDRESS THE NOTIFICATION AND COORDINATION REQUIREMENTS WITH THE LANDOWNERS, UTILITY OPERATORS, AND PIPELINE COMPANIES. AS-BUILT DRAWINGS AND/OR PLATS SHALL HAVE WRITTEN ON THEM THE DATE OF COMPLETION OF SAID ACTIVITIES AND SHALL BE SUBMITTED TO THE LOUISIANA DEPARTMENT OF NATURAL RESOURCES, OFFICE OF COASTAL MANAGEMENT, P.O. BOX 44487, BATON ROUGE, LA 70804-4487 WITHIN 30 DAYS FOLLOWING PROJECT COMPLETION. THIS DRAWING SET IS FOR PERMITTING PURPOSES ONLY AND IS NOT TO BE USED FOR CONSTRUCTION.

SURVEY NOTES: 1.

2.

3. 4.

5. 6.

ALL COORDINATES ARE NORTH AMERICAN DATUM OF 1983 (NAD 83 - GEOID 12B), LOUISIANA STATE PLANE, SOUTHERN ZONE, U.S. SURVEY FEET. ALL RESTORATION AREA ELEVATIONS ARE BASED ON NATIONAL GEODETIC SURVEY AND LOUISIANA DEPARTMENT OF NATURAL RESOURCES MONUMENTS. MONUMENTS ELEVATION NORTHING EASTING TE23-SM-01 7.30' 224,296.33 3,645,688.77 TE118-SM-01 2.16' 207,570.44 3,601,096.02 TE118-SM-02 3.06' 207,952,34 3,604,313.92 TE118-SM-03 1.56' 228,233.63 3,597,696.59 OTHER LOCAL AREA SECONDARY MONUMENTS REQUIRING UPDATES. MONUMENTS ELEVATION NORTHING EASTING LAST UPDATE TE40-SM-01 5.00' 206,444.36 3,554,437.49 SEPT. 2003 TRINITY 4.67' 200,955.97 3,476,498.85 APR. 2002 ALL ELEVATIONS ARE IN NORTH AMERICAN VERTICAL DATUM OF 1988 (NAVD88 - 2004.65), U.S. SURVEY FEET UNLESS OTHERWISE SPECIFIED. SHIP SHOAL BORROW AREA PERFORMED BY OCEAN SURVEYS, INC., 2015-16. SOUTH PELTO BORROW AREA SURVEY PERFORMED BY OCEAN SURVEYS, INC. 2011. TRINITY-EAST PUMP-OUT AREAS, TRINITY-EAST CONVEYANCE CORRIDOR, TIMBALIER PUMP-OUT AREAS, TIMBALIER CONVEYANCE CORRIDOR ELEVATIONS REFERENCED TO MLLW OBTAINED FROM NOAA NAUTICAL CHART 11357 "TIMBALIER AND TERREBONNE BAYS", 42nd EDITION, MAY 2012, NOS SURVEYS 1990-2011. ALL ISLAND SURVEYS PROVIDED BY CPRA AS PART OF THE BARRIER ISLAND COMPREHENSIVE MONITORING PROGRAM, 2016. INFORMATION SHOWN HERE IN REFLECTS CONDITIONS AS THEY EXISTED ON THE SURVEY DATE SHOWN AND CAN ONLY BE CONSIDERED INDICATIVE OF CONDITIONS AT THAT TIME.

BY

DESCRIPTION

DATE

COASTAL ENGINEERING CONSULTANTS, INC. PH: (225) 768-1982 8570 ANSELMO LANE BATON ROUGE, LA 70810

DRAWN BY: STEVE DARTEZ

DESIGNED BY: MICHAEL T. POFF, P.E. LICENSE NUMBER: 30048

LOUISIANA COASTAL PROTECTION AND RESTORATION AUTHORITY 150 TERRACE AVENUE BATON ROUGE, LA 70802

APPROVED BY: TRAVIS BYLAND, P.E.

TERREBONNE BASIN BARRIER ISLAND AND BEACH NOURISHMENT

GENERAL NOTES

STATE PROJECT NUMBER: TE-143

DATE: APRIL 2018

FEDERAL PROJECT NUMBER:

SHEET 3 OF 36

PL

PL

PL

PL

WA

WA

WA

PL

PL

PL PL

WA

WA PL

WA

WA PL

WA

PL

00+00

20+00

60+00

80+00

00

PL

PL

PL PL

100+00

WA

00 220 +

PL

PL

00

00 160 +

PL

WA PL

00 240 +

3,565,000 E

PL

3,555,000 E

PL PL

3,545,000 E PL

PL

PL

PL

PL

PL PL PL

PL

PL PL

180 +

PL

WA

WA

120 +

WA

00

PL

00

WA

140 +

40+00

PL

WA

WA WA

WA

WA

WA

PL

SURVEY BASELINE

PL

PL

WA

PL

PL

WA

WA

TBBL-02

WA

PL

PL

WA

WA

WA

PL

WA

PL PL

PL

WA

A

TBBL-01

WA

PL

PL

W

WA

PL

WA

WA

WA WA

200 +

A

WA

WA

WA

PL

PL

PL

A

PL

PL

PL

W

PL

PL

PL

PL

WA

PL

PL

PL

WA WA

WA

PL

A'

PL

PL

PL

PL

PL

PL

PL

PL

PLPL

PL

PL

WA

PL

BEGINNING OF PROJECT (TB-01)

PL

WA

B

PL

PL

PL PL PL

PL

WA

PL

PL

WA

WA

WA

PL

PL PL

TIMBALIER ISLAND

WA

PL

PL

WA

PL

WA

WA

PL

WA

WA

WA

B'

WA

PL

WA

PL

WA

PL

211,000 N

PL

WA

WA

END OF PROJECT (TB-02)

PL

211,000 N

WA

WA

TBBL-03

PL PL

WA PL

211,000 N

PL

WA

PL

PL

WA

TIMBALIER BAY

WA

PL

L

WA

PL

PL

TIMBALIER CONVEYANCE PL CORRIDOR ALIGNMENT

PL

PL

PL PL

PL

PL

PL

PL

PL

PL

PL

2,500'

DATE

COASTAL ENGINEERING CONSULTANTS, INC. PH: (225) 768-1982 8570 ANSELMO LANE BATON ROUGE, LA 70810

DRAWN BY: BRETT BORNE, P.E.

DESIGNED BY: MICHAEL T. POFF, P.E. LICENSE NUMBER: 30048

PL

DESCRIPTION

DUNE CREST

PL

PL

FILL EXTENTS WA

WORK AREA

PL

PROBABLE PIPELINE (CMD, 2010 & BOEM, 2007)

PL

PL

PL

3,545,000 E

PL PL PL

CONVEYANCE CORRIDOR ACCESS CHANNEL ALIGNMENT

BEACH CREST

PL

NOTES: PL 1. ALL COORDINATES ARE NAD83, LOUISIANA STATE PLANE, U.S. SURVEY FEET. 2. AERIAL IMAGE REFERENCE: ©2018 MICROSOFT CORPORATION ©2018 DIGITALGLOBE ©CNES (2018) DISTRIBUTION AIRBUS DS; BING. 3. SAND FENCING SHALL BE INSTALLED ALONG THE ALIGNMENT AND FOR THE LENGTH OF THE DUNE. 4. SEE SHEET 33 FOR ALIGNMENT AND COORDINATE TABLES. 5. FILL EXTENTS ARE APPROXIMATE AND WILL VARY DUE TO BARRIER ISLAND DYNAMICS. LIMITS OF FILL SHALL BE FIELD ADJUSTED AT TIME OF CONSTRUCTION.

201,000 N

3,555,000 E

PL PL PL

PL PL

BY

0'

PL

PL

PL

1,250'

LEGEND

PL PL PL

PL

2,500'

PL

PL

201,000 N

PL

PL OF MEXICO GULF PL

PL

PL

PL

BEACH/DUNE FILL MARSH FILL

LOUISIANA COASTAL PROTECTION AND RESTORATION AUTHORITY 150 TERRACE AVENUE BATON ROUGE, LA 70802

APPROVED BY: TRAVIS BYLAND, P.E.

TERREBONNE BASIN BARRIER ISLAND AND BEACH NOURISHMENT

TIMBALIER ISLAND NOURISHMENT AREA PLAN VIEW

STATE PROJECT NUMBER: TE-143

DATE: APRIL 2018

FEDERAL PROJECT NUMBER:

SHEET 4 OF 36

NOTES: 1. 2. 3. 4. 5.

LEGEND

SECTIONS ARE VIEWED AS LOOKING WEST. EXISTING GRADE SURVEY PROVIDED BY CPRA AS PART OF THE BARRIER ISLAND COMPREHENSIVE MONITORING PROGRAM, 2016. DIMENSIONS ARE PROVIDED FOR DESIGN PURPOSES AND MAY NOT MEASURE ALONG THE SURVEY BASELINE. A +1.0 FT ELEVATION CONSTRUCTION TOLERANCE SHALL BE ACCOMMODATED FOR CONSTRUCTION PURPOSES. MEAN HIGH WATER (MHW) AND MEAN LOW WATER (MLW) DATA DERIVED FROM THE EAST TIMBALIER ISLAND RESTORATION PROJECT (TE-118).

ELEVATION (NAVD88, FT)

15

SCALE: EXISTING GRADE (2016)

H: 1" = 500' V: 1" = 25'

BEACH & DUNE FILL

CONSTRUCTION TOLERANCE

MARSH FILL

SOUTH

NORTH

A - A'

10

TARGET EL. +4.5' 1

25

5

TARGET EL. +2.0'

15 10

25

5

1

1

MHW = +0.88'

0

100' TARGET EL. +7.0'

25

0

MLW = -0.37'

100'

429'

-5

-5

391'

-10

-10 -15 -2000

-1000

-1500

-500

500

0

1000

1500

-15 2000

DISTANCE FROM BASELINE (FT)

ELEVATION (NAVD88, FT)

15

SOUTH

10

NORTH

B - B'

25

TARGET EL. +7.0'

1

TARGET EL. +4.5'

5 0

100'

TARGET EL. +2.0' 25 1

10 5

MHW = +0.88' MLW = -0.37'

0

25 1

-5

228' -1000

-1500

-5

391'

-10 -15 -2000

15

100'

-10 0

-500

500

1000

1500

-15 2000

DISTANCE FROM BASELINE (FT)

BY

DESCRIPTION

DATE

COASTAL ENGINEERING CONSULTANTS, INC. PH: (225) 768-1982 8570 ANSELMO LANE BATON ROUGE, LA 70810

DRAWN BY: BRETT BORNE, P.E.

DESIGNED BY: MICHAEL T. POFF, P.E. LICENSE NUMBER: 30048

LOUISIANA COASTAL PROTECTION AND RESTORATION AUTHORITY 150 TERRACE AVENUE BATON ROUGE, LA 70802

APPROVED BY: TRAVIS BYLAND, P.E.

TERREBONNE BASIN BARRIER ISLAND AND BEACH NOURISHMENT

TIMBALIER ISLAND NOURISHMENT TYPICAL SECTIONS

STATE PROJECT NUMBER: TE-143

DATE: APRIL 2018

FEDERAL PROJECT NUMBER:

SHEET 5 OF 32

PL

PL

DUNE CREST

LEGEND: ACCESS CHANNEL

WA

PL

PL

214,000 N

EXISTING EL. -8'

WA

BEACH CREST

TBAW-01 WA

WA

3,547,500 E

214,000 N

WA

3,543,500 E

FILL EXTENTS

3,545,500 E

P

LEGEND PL

,

TEMPORARY SIDECAST DISPOSAL EXISTING EL. -7'

WA

PL

PL

WA

BEACH/DUNE FILL

EXISTING GRADE (2016)

WA

3,547,500 E

3,545,500 E

212,000 N

WA

PROBABLE PIPELINE (CMD, 2010)

EXISTING EL. -5'

PL

WA

PL

5

EXISTING EL. -4'

WA

EXISTING EL. -3'

PL

PL

WA

WA

PL

C'

C

WA

WA

00 PL

150' (MAX)

30' BERM (MIN)

-10

-15

-15 -600

0

600

DISTANCE FROM ALIGNMENT (FT)

NOTES: 1. CROSSING OF OIL & GAS PIPELINES SHALL BE IN ACCORDANCE WITH PIPELINE OWNER AND CONSTRUCTION CONTRACTOR CROSSING AGREEMENTS. 2. MATERIAL REMAINING IN THE TEMPORARY SIDECAST DISPOSAL AREAS SHALL BE REWORKED TO ±0.5 FEET OF THE PRE-CONSTRUCTION ELEVATIONS PRIOR TO DEMOBILIZATION. 3. ELEVATIONS IN THE ACCESS CHANNEL RESULTING FROM BACKFILLING OPERATIONS SHALL BE NO HIGHER THAN +0.5 FEET OF THE PRE-CONSTRUCTION ELEVATION. 4. EXISTING GRADE SURVEY PROVIDED BY CPRA AS PART OF THE BARRIER ISLAND COMPREHENSIVE MONITORING PROGRAM, 2016. 5. ALL COORDINATES ARE NAD83, LOUISIANA STATE PLANE, U.S. SURVEY FEET. 6. AERIAL IMAGE FROM ©2018 MICROSOFT CORPORATION ©2018 DIGITALGLOBE ©CNES (2018) DISTRIBUTION AIRBUS DS; BING. 7. SEE SHEET 33 FOR ALIGNMENT AND COORDINATE TABLES.

PL

220 +

00

WA

120' (MAX)

EL.= -9.0'(MAX)

WA

210 +

00

WA

30' BERM (MIN)

210,000 N

230 +

5

60' (MAX)

-5

-10

WA

00

PL

240 +

10

190' (MAX)

120' (MAX)

WA

00

WA

PL

200 +

WA

1,000'

EL. = +2.0' (MAX)

(TYP) 1

-5

WA

PL

WA

0'

WEST

0

W

208,000 N

6

60' (MAX)

MLW = -0.37'

EXISTING EL. -1'

WA

PL

3,543,500 E

MHW = +0.88' 0

A TBAW-03

SURVEY BASELINE

500'

EL. = +2.0' (MAX)

EXISTING EL. -2'

WA

WA

3,547,500 E

3,545,500 E

WA PL

WA

210,000 N

WA

WA

TBAW-02 WA

PL

3,543,500 E

WA

WA

PL

WA

210,000 N

1,000'

C - C'

10

ELEVATION (NAVD88, FT)

PL

L

212,000 N

WA

PL

EXISTING EL. -6'

DESIGN SCALE: H: 1" = 300' V: 1" = 15' EAST

AREA 212,000WORK N PL

PL

PL

WA

TEMPORARY SIDECAST DISPOSAL

WA

3,543,500 E P

ACCESS CHANNEL

WA

PL

WA

PL

MARSH FILL

WA

DESCRIPTION

DATE

WA

BY

COASTAL ENGINEERING CONSULTANTS, INC. PH: (225) 768-1982 8570 ANSELMO LANE BATON ROUGE, LA 70810

DRAWN BY: STEVE DARTEZ

DESIGNED BY: MICHAEL T. POFF, P.E. LICENSE NUMBER: 30048

LOUISIANA COASTAL PROTECTION AND RESTORATION AUTHORITY 150 TERRACE AVENUE BATON ROUGE, LA 70802

APPROVED BY: TRAVIS BYLAND, P.E.

TERREBONNE BASIN BARRIER ISLAND AND BEACH NOURISHMENT

TIMBALIER ISLAND ACCESS CHANNEL - WEST

STATE PROJECT NUMBER: TE-143

DATE: APRIL 2018

FEDERAL PROJECT NUMBER:

SHEET 6 OF 36

LEGEND

WA

PL PL

EXISTING EL. -9'

TEMPORARY SIDECAST DISPOSAL

EXISTING EL. -8'

WA

MARSH FILL

ACCESS CHANNEL

WA

PL

BEACH/DUNE FILL

LEGEND:

210,000 N

WA

BEACH CREST

WA

WA

3,556,500 E

DUNE CREST

TBAE-01

WA

210,000 N

3,558,500 E

PL

FILL EXTENTS

WA

3,554,500 E

210,000 N

EXISTING GRADE (2016)

WA

208,000 N

5

PL

208,000 N

EXISTING EL. -5'

WA

WA

PL

EXISTING EL. -4'

WA

PL

3,554,500 E

WA

PL

PL

PL

00

WA

WA

WA

WA

WA

WA

206,000 N

-5

PL

DATE

204,000 N

COASTAL ENGINEERING CONSULTANTS, INC.

WA

WA

00 WA

WA

WA

PH: (225) 768-1982 8570 ANSELMO LANE BATON ROUGE, LA 70810

DRAWN BY: STEVE DARTEZ

DESIGNED BY: MICHAEL T. POFF, P.E. LICENSE NUMBER: 30048

3,558,500 E

90+00

100+00 WA

120 +

PL

00

WA

PL

110 +

WA

PL

WA

PL

WA

WA WA

DESCRIPTION

WA

BY

SURVEY BASELINE

1,000'

150' (MAX)

120' (MAX) 30' BERM (MIN)

-10

-15 0

600

NOTES: 1. CROSSING OF OIL & GAS PIPELINES SHALL BE IN ACCORDANCE WITH PIPELINE OWNER AND CONSTRUCTION CONTRACTOR CROSSING AGREEMENTS. 2. MATERIAL REMAINING IN THE TEMPORARY SIDECAST DISPOSAL AREAS SHALL BE REWORKED TO ±0.5 FEET OF THE PRE-CONSTRUCTION ELEVATIONS PRIOR TO DEMOBILIZATION. 3. ELEVATIONS IN THE ACCESS CHANNEL RESULTING FROM BACKFILLING OPERATIONS SHALL BE NO HIGHER THAN +0.5 FEET OF THE PRE-CONSTRUCTION ELEVATION. 4. EXISTING GRADE SURVEY PROVIDED BY CPRA AS PART OF THE BARRIER ISLAND COMPREHENSIVE MONITORING PROGRAM, 2016. 5. ALL COORDINATES ARE NAD83, LOUISIANA STATE PLANE, U.S. SURVEY FEET. 6. AERIAL IMAGE REFERENCE: ©2018 MICROSOFT CORPORATION ©2018 DIGITALGLOBE ©CNES (2018) DISTRIBUTION AIRBUS DS; BING. 7. SEE SHEET 33 FOR ALIGNMENT AND COORDINATE TABLES.

A

0'

0

DISTANCE FROM ALIGNMENT (FT)

80+00

500'

30' BERM (MIN)

5

60' (MAX)

-5

120' (MAX)

-600

206,000 N

TBAE-02

1,000'

EL. = +2.0' (MAX)

(TYP) 1 170' (MAX)

MLW = -0.37'

PL

130 +

EXISTING EL. -1'

WA

MHW = +0.88' 0

6

60' (MAX)

10

-15

3,558,500 E

PL

D

WA

WEST

EL.= -9.0'(MAX)

WA

WA

EL. = +2.0' (MAX)

-10

PL WA

EXISTING EL. -3'

WA

D'

WA

PL

WA

WA

EXISTING EL. -2' PL

D - D'

EAST 10

ELEVATION (NAVD88, FT)

WA

WA

PROBABLE PIPELINE PL 208,000 N (CMD, 2010)

WA

PL

WORK AREA

3,558,500 E

PL

TEMPORARY SIDECAST DISPOSAL

3,556,500 E

3,554,500 E

DESIGN SCALE: H: 1" = 300' V: 1" = 15'

EXISTING EL. -6' WA

WA

WA

PL

EXISTING EL. -7'

ACCESS CHANNEL

LOUISIANA COASTAL PROTECTION AND RESTORATION AUTHORITY 150 TERRACE AVENUE BATON ROUGE, LA 70802

APPROVED BY: TRAVIS BYLAND, P.E.

TERREBONNE BASIN BARRIER ISLAND AND BEACH NOURISHMENT

TIMBALIER ISLAND ACCESS CHANNEL - EAST

STATE PROJECT NUMBER: TE-143

DATE: APRIL 2018

FEDERAL PROJECT NUMBER:

SHEET 7 OF 36

LEGEND PL

FILL EXTENTS

TBDR-01

WA

WA

WA

WA

211,000 N

PL

WA

EXISTING EL. -7'

3,564,500 E

WA

WA WA

PL

WA

PL

E PL

WA

WA

PL

PL

PL

PL

TBDR-02

EXISTING EL. -3'

PL

PL

A

EXISTING EL. -1'

WA

MHW = +0.88' 0

175' (MAX)

120' (MAX) 30' BERM (MIN)

-10

150' (MAX)

120' (MAX)

EL.= -9.0'(MAX)

30' BERM (MIN)

-10

-15

-15 0

600

NOTES: 1. CROSSING OF OIL & GAS PIPELINES SHALL BE IN ACCORDANCE WITH PIPELINE OWNER AND CONSTRUCTION CONTRACTOR CROSSING AGREEMENTS. 2. MATERIAL REMAINING IN THE TEMPORARY SIDECAST DISPOSAL AREAS SHALL BE REWORKED TO ±0.5 FEET OF THE PRE-CONSTRUCTION ELEVATIONS PRIOR TO DEMOBILIZATION. 3. ELEVATIONS IN THE ACCESS CHANNEL RESULTING FROM BACKFILLING OPERATIONS SHALL BE NO HIGHER THAN +0.5 FEET OF THE PRE-CONSTRUCTION ELEVATION. 4. EXISTING GRADE SURVEY PROVIDED BY CPRA AS PART OF THE BARRIER ISLAND COMPREHENSIVE MONITORING PROGRAM, 2016. 5. ALL COORDINATES ARE NAD83, LOUISIANA STATE PLANE, U.S. SURVEY FEET. 6. AERIAL IMAGE REFERENCE: ©2018 MICROSOFT CORPORATION ©2018 DIGITALGLOBE ©CNES (2018) DISTRIBUTION AIRBUS DS; BING. 7. SEE SHEET 33 FOR ALIGNMENT AND COORDINATE TABLES.

PL

TBDR-04

PL

WA

40+00

WA

50+00

WA

WA

WA

60+00

WA

WA

WA

DESCRIPTION

30+00

WA

205,000 N

205,000 N

20+00 3,564,500 E

PL

PL

3,560,500 E

-5

DISTANCE FROM ALIGNMENT (FT)

WA

70+00

5

45' (MAX)

-5

PL

DOCK

0'

SURVEY BASELINE

1,200'

DATE

COASTAL ENGINEERING CONSULTANTS, INC.

WA

WA

PH: (225) 768-1982 8570 ANSELMO LANE BATON ROUGE, LA 70810

DRAWN BY: STEVE DARTEZ

EL. = +2.0' (MAX)

(TYP) 1

0

TBDR-03

BY

6

45' (MAX)

MLW = -0.37'

WA

600'

10

A

1,200'

WEST

W

WA

WA

WA

WA

PL

WA

EL. = +2.0' (MAX)

-600

207,000 N

PL

W

A

207,000 N

W

EXISTING EL. -2'

ELEVATION (NAVD88, FT)

WA WA

PL PL

EXISTING EL. -4'

E - E'

EAST 10

5

EXISTING EL. -5'

E'

SCALE: H: 1" = 300' V: 1" = 15'

209,000 N

EXISTING EL. -6'

PROBABLE PIPELINE (CMD, 2010)

3,560,500 E

209,000 N

WA

WORK AREA

PL

3,562,500 E

WA

WA

PL

DOCK

DESIGN

WA

PL

TEMPORARY SIDECAST DISPOSAL

EXISTING GRADE (2016)

EXISTING EL. -8'

PL

ACCESS CHANNEL

TEMPORARY SIDECAST DISPOSAL

WA

MARSH FILL

3,564,500 E

WA

WA

PL

BEACH/DUNE FILL

ACCESS CHANNEL

211,000 N

3,562,500 E

BEACH CREST

3,564,500 E

PL

DUNE CREST

WA

LEGEND:

EXISTING EL. -9'

DESIGNED BY: MICHAEL T. POFF, P.E. LICENSE NUMBER: 30048

LOUISIANA COASTAL PROTECTION AND RESTORATION AUTHORITY 150 TERRACE AVENUE BATON ROUGE, LA 70802

APPROVED BY: TRAVIS BYLAND, P.E.

TERREBONNE BASIN BARRIER ISLAND AND BEACH NOURISHMENT

TIMBALIER ISLAND DOCK REMOVAL ACCESS CHANNEL

STATE PROJECT NUMBER: TE-143

DATE: APRIL 2018

FEDERAL PROJECT NUMBER:

SHEET 8 OF 36

10 EQUAL SPACES @ 10'-0" O.C. 10' (TYP.)

8' EL. +7.0' NAVD88 7' (TYP.)

3"x12"x8' C.C.A. TREATED TIMBER DECKING, EL. +4.0' NAVD88

CLASS "B" TREATED TIMBER PILE LENGTH: 30' (TYP.), EL. +7.0' NAVD88

EL. +4.0' NAVD88 MHW = +0.88' NAVD88 MLW = -0.37' NAVD88

4"x8" TREATED TIMBER X-BRACES

8"x12" TREATED TIMBER BOARDS

ELEVATION VIEW TIMBALIER ISLAND DOCK FACILITY NOT TO SCALE

102' 10 EQUAL SPACES @ 10'-0" O.C. 3"x12"x8' C.C.A. TREATED TIMBER DECKING

1'

SECTION 1 - 1' DOCK DETAIL (TIMBER) NOT TO SCALE

1

NOTES: 1. DOCK INSTALLED AS PART OF TIMBALIER ISLAND DUNE/MARSH RESTORATION PROJECT (TE-40). 2. ALL MATERIALS REMAINING AS PART OF THE DOCK SHALL BE REMOVED AND DISPOSED OF IN AN APPROVED DISPOSAL FACILITY IN ACCORDANCE WITH ALL FEDERAL AND STATE LAWS. 3. ALL PILINGS ASSOCIATED WITH THE DOCK STRUCTURE SHALL BE REMOVED TO A DEPTH OF AT LEAST TEN (10) FEET BELOW EXISTING GROUND. 4. DOCK FASTENING HARDWARE IS COMPRISED OF 7/8" GALVANIZED BOLTS WITH O.G. WASHERS AND NUTS. 5. ELEVATIONS OF CONSTRUCTION ARE ONLY RELEVANT TO THE TIME OF CONSTRUCTION AND MAY NOT REFLECT CURRENT CONDITIONS. 6. DOCK DRAWINGS OBTAINED FROM THE TIMBALIER ISLAND DUNE/MARSH RESTORATION PROJECT (TE-40) AS-BUILT DRAWINGS. BY

DESCRIPTION

DATE

PLAN VIEW NOT TO SCALE

COASTAL ENGINEERING CONSULTANTS, INC. PH: (225) 768-1982 8570 ANSELMO LANE BATON ROUGE, LA 70810

DRAWN BY: STEVE DARTEZ

DESIGNED BY: MICHAEL T. POFF, P.E. LICENSE NUMBER: 30048

LOUISIANA COASTAL PROTECTION AND RESTORATION AUTHORITY 150 TERRACE AVENUE BATON ROUGE, LA 70802

APPROVED BY: TRAVIS BYLAND, P.E.

TERREBONNE BASIN BARRIER ISLAND AND BEACH NOURISHMENT

TIMBALIER ISLAND DOCK REMOVAL DETAIL

STATE PROJECT NUMBER: TE-143

DATE: APRIL 2018

FEDERAL PROJECT NUMBER:

SHEET 9 OF 32

PL

PL

3,491,000 E

WA

WA

WA WA

PL

3,479,000 E

PL

WA

WA

WA

S OY

S

A

WA

S OY

WA

WA

WA WA

WA

WA

PL

PL

PL

PL

PL

PL

PL

197,000 N

3,491,000 E

WA

YS O

WA

YS

O

OY WA

WA

W

PL

OYS

OYS

A

S OY

280+00

300+00

3,467,000 E

W

PL

PL

PL

PL

PL

197,000 NPL

PL

PL

PL PL PL

NOTES: 1. ALL COORDINATES ARE NAD83, LOUISIANA STATE PLANE, U.S. SURVEY FEET. 2. AERIAL IMAGE REFERENCE: ©2018 MICROSOFT CORPORATION ©2018 DIGITALGLOBE ©CNES (2018) DISTRIBUTION AIRBUS DS; BING. 3. SAND FENCING SHALL BE INSTALLED ALONG THE ALIGNMENT AND FOR THE LENGTH OF THE FILL. 4. SEE SHEET 34 FOR ALIGNMENT AND COORDINATE TABLES. 5. UPLAND ACCESS CORRIDOR SHALL BE ALLOWED ONLY OVER UNVEGETATED SEGMENTS OF ISLAND. 6. FILL EXTENTS ARE APPROXIMATE AND WILL VARY DUE TO BARRIER ISLAND DYNAMICS. LIMITS OF FILL SHALL BE FIELD ADJUSTED AT TIME OF CONSTRUCTION.

3,000'

DATE

COASTAL ENGINEERING CONSULTANTS, INC. PH: (225) 768-1982 8570 ANSELMO LANE BATON ROUGE, LA 70810

DRAWN BY: BRETT BORNE, P.E.

PL

PL

197,000 N

DESCRIPTION

PL

PL

G

0'

SURVEY BASELINE

PL

GULF OF MEXICO

TEBL-01

TEBL-02

PL

F

PL

TRINITY/EAST CONVEYANCE CORRIDOR ALIGNMENT

1,500'

A

WA

PL

140+00

WA

PL

200+00

220+00

WA

260+00

WA

WA

240+00

A

WA

WA

PL WA

WA

180+00

PL

WA

160+00

A

PL

W

TEBL-03

WA

0 60+0

PL

W

PLOYS

A

PL

PL

PL OYS

W

00 100+

G'

PL

END OF PROJECT (TE-02)

PL

A

BEGINNING OF PROJECT (TE-01) 00 120+

PL

W

PL

WA

OY S

F'

0 80+0

S OY S OY

OYS

PL

PL

PL

PL

PL

OYS

PL

W

PL

3,479,000 E

3,467,000 E

PL

PL

PLPL

PL

PL

OYS PL

PL

TRINITY- EAST ISLAND 0 40+0

PL

WA

PL

PL

WA

PL

0 20+0

PL

WA

PL

PL

WA

PL

PL

0 00+0

PLPL

WA

WA

PL

PL PL

BY

209,000 N

WA

PL

3,000'

209,000 N

PL

PLPL

LAKE PELTO

WA

PLPL

209,000 N

DESIGNED BY: MICHAEL T. POFF, P.E. LICENSE NUMBER: 30048

LOUISIANA COASTAL PROTECTION AND RESTORATION AUTHORITY 150 TERRACE AVENUE BATON ROUGE, LA 70802

APPROVED BY: TRAVIS BYLAND, P.E.

LEGEND PL PL

ACCESS CHANNEL UPLAND ACCESS PL CORRIDOR PL WORK AREA PL

PL

BEACH CREST FILL EXTENTS

WA

BEACH FILL

OYS

CONVEYANCE CORRIDOR TERREBONNE BASIN BARRIER ISLAND AND BEACH NOURISHMENT

PL

OYSTER LEASE (LDWF, 2018) PROBABLE PIPELINE (CMD 2010, BOEM, 2007) TRINITY-EAST ISLAND NOURISHMENT AREA PLAN VIEW

STATE PROJECT NUMBER: TE-143

DATE: APRIL 2018

FEDERAL PROJECT NUMBER:

SHEET 10 OF 36

LEGEND

NOTES: 1. 2. 3. 4. 5.

6.

SECTIONS ARE VIEWED AS LOOKING WEST. EXISTING GRADE SURVEY PROVIDED BY CPRA AS PART OF THE BARRIER ISLAND COMPREHENSIVE MONITORING PROGRAM, 2016. DIMENSIONS ARE PROVIDED FOR DESIGN PURPOSES AND MAY NOT MEASURE ALONG THE SURVEY BASELINE. A +1.0 FT ELEVATION CONSTRUCTION TOLERANCE SHALL BE ACCOMMODATED FOR CONSTRUCTION PURPOSES. FULL POSSIBLE TEMPLATE EXTENTS SHOWN FOR CONSISTENCY WITH THE DESIGN PLAN VIEW AND TO ACCOUNT FOR POTENTIAL CHANGES IN THE EXISTING GRADE BETWEEN PERMITTING AND CONSTRUCTION. NO EXISTING TOPOGRAPHY WILL BE DEGRADED BELOW DESIGN TEMPLATE ELEVATIONS. MEAN HIGH WATER (MHW) AND MEAN LOW WATER (MLW) DATA DERIVED FROM THE EAST TIMBALIER ISLAND RESTORATION PROJECT (TE-118).

ELEVATION (NAVD88, FT)

15

BEACH FILL

DESIGN

CONSTRUCTION TOLERANCE

POSSIBLE DESIGN EXTENTS

POSSIBLE TOLERANCE EXTENTS

NORTH

F - F'

10

859'

TARGET EL. +5.0' 25 1

5

10 5

MHW = +0.88'

0

15

0

MLW = -0.37'

-5

-5

-10

-10

15 ELEVATION (NAVD88, FT)

H: 1" = 500' V: 1" = 25'

SOUTH

-15 -2000

-1500

-1000

-500

0 DISTANCE FROM BASELINE (FT)

500

1000

1500

SOUTH

10

1000'

TARGET EL. +5.0'

15 10

25

5 0

-15 2000

NORTH

G - G'

5 1

MHW = +0.88'

0

MLW = -0.37'

-5

-5

-10

-10

-15 -2000

BY

SCALE: EXISTING GRADE (2016)

DESCRIPTION

-1500

-1000

DATE

-500

0 DISTANCE FROM BASELINE (FT)

COASTAL ENGINEERING CONSULTANTS, INC. PH: (225) 768-1982 8570 ANSELMO LANE BATON ROUGE, LA 70810

DRAWN BY: BRETT BORNE, P.E.

DESIGNED BY: MICHAEL T. POFF, P.E. LICENSE NUMBER: 30048

500

LOUISIANA COASTAL PROTECTION AND RESTORATION AUTHORITY 150 TERRACE AVENUE BATON ROUGE, LA 70802

APPROVED BY: TRAVIS BYLAND, P.E.

1000

1500

TERREBONNE BASIN BARRIER ISLAND AND BEACH NOURISHMENT

-15 2000

TRINITY-EAST ISLAND NOURISHMENT TYPICAL SECTIONS

STATE PROJECT NUMBER: TE-143

DATE: APRIL 2018

FEDERAL PROJECT NUMBER:

SHEET 11 OF 36

A

OY

S

A

WA

OYS OY S

WA

WA

PL PL

WA

WA WA

WA

WA

WA

WA

WA

WA

WA

WA

WA WA

WA WA

WA WA

WA

WA

WA

PL

WA

WA WA

240+00

TEUC-02

WA WA

WA

WA

WA

WA

PL

WA

PL A W

WA

PL

WA

WA

WA

WA

WA

WA

PL

WA

WA

A

PL

WA PL

W

PL

WA

A

PL

PL

W

PL

PL

160+00

200+00

220+00

PL

WA

180+00

WA

PL

WA

WA

PL

W

OYS

A

WA

PL

W

PL

TEUC-01

A

WA

YS O

PL

W

202,500 N

W

PL

PL

OYS

3,478,500 E

3,474,500 E

S OYS

WA

PL

WA

OYS

A

202,500 N

W

WA

A PL PL

OYS

W

3,470,500 E

A

PL

PL

PL

W

OY

WA

A

WA

PL

202,500 N

PL

W

WA

PL

WA

OYS

A

PL

W

PL

PL

WA

S OY

A

PL

PL

W

WA

PL

PL

PL

PL

PL

TEUC-03

PL

WA

PL

WA

PL

TEUC-05

PL PL PL PL PL

3,474,500 E

3,470,500 E

TEUC-04

PL PL PL PL PL

198,500 N

LEGEND

198,500 N

PL PL

BEACH CREST

1,000'

500'

0'

BY

DESCRIPTION

NOTES: 1. ALL COORDINATES ARE NAD83, LOUISIANA STATE PLANE, U.S. SURVEY FEET. 2. AERIAL IMAGE REFERENCE: ©2018 MICROSOFT CORPORATION ©2018 DIGITALGLOBE ©CNES (2018) DISTRIBUTION AIRBUS DS; BING. 3. SEE SHEET 34 FOR ALIGNMENT AND COORDINATE TABLES. 4. UPLAND ACCESS CORRIDOR SHALL BE ALLOWED ONLY OVER UNVEGETATED SEGMENTS OF ISLAND.

1,000'

DATE

COASTAL ENGINEERING CONSULTANTS, INC. PH: (225) 768-1982 8570 ANSELMO LANE BATON ROUGE, LA 70810

DRAWN BY: STEVE DARTEZ

DESIGNED BY: MICHAEL T. POFF, P.E. LICENSE NUMBER: 30048

LOUISIANA COASTAL PROTECTION AND RESTORATION AUTHORITY 150 TERRACE AVENUE BATON ROUGE, LA 70802

APPROVED BY: TRAVIS BYLAND, P.E.

FILL EXTENTS BEACH/DUNE FILL ACCESS CHANNEL ALIGNMENT

WA

OYS

PL

CONVEYANCE PL CORRIDORSPL UPLAND ACCESS PL CORRIDOR WORK AREA OYSTER LEASE (LDWF, 2018) PROBABLE PIPELINE (CMD, 2010)

TERREBONNE BASIN TRINITY-EAST ISLAND BARRIER ISLAND AND BEACH UPLAND ACCESS CORRIDOR NOURISHMENT STATE PROJECT NUMBER: TE-143

DATE: APRIL 2018

FEDERAL PROJECT NUMBER:

SHEET 12 OF 36

LEGEND PL

OYS

PL S O Y PL

S OY

PL

BEACH FILL

S OY

S OY

YS O

OY

WA OYS

WA

3,470,500 E

WA WA WA

EXISTING EL. -1'

S

WA

OY S

WA

OYS

WA

WA

PL PL

OYS

WA

WA

WA

PL PL WA

PL PL PL

S OY

WA

WA

200,500 N

WA

PL

WA

220+00

WA

198,500 N

198,500 N

1,000'

500'

0'

BY

DESCRIPTION

-5

170' (MAX)

140' (MAX) 30' BERM (MIN)

150' (MAX)

140' (MAX)

EL.= -9.0'(MAX)

30' BERM (MIN)

-10

-15

-15 -600

0

600

DISTANCE FROM ALIGNMENT (FT)

NOTES: 1. CROSSING OF OIL & GAS PIPELINES SHALL BE IN ACCORDANCE WITH PIPELINE OWNER AND CONSTRUCTION CONTRACTOR CROSSING AGREEMENTS. 2. MATERIAL REMAINING IN THE TEMPORARY SIDECAST DISPOSAL AREAS SHALL BE REWORKED TO ±0.5 FEET OF THE PRE-CONSTRUCTION ELEVATIONS PRIOR TO DEMOBILIZATION. 3. ELEVATIONS IN THE ACCESS CHANNEL RESULTING FROM BACKFILLING OPERATIONS SHALL BE NO HIGHER THAN +0.5 FEET OF THE PRE-CONSTRUCTION ELEVATION. 4. EXISTING GRADE SURVEY PROVIDED BY CPRA AS PART OF THE BARRIER ISLAND COMPREHENSIVE MONITORING PROGRAM, 2016. 5. ALL COORDINATES ARE NAD83, LOUISIANA STATE PLANE, U.S. SURVEY FEET. 6. AERIAL IMAGE REFERENCE: ©2018 MICROSOFT CORPORATION ©2018 DIGITALGLOBE ©CNES (2018) DISTRIBUTION AIRBUS DS; BING. 7. SEE SHEET 34 FOR ALIGNMENT AND COORDINATE TABLES. 8. UPLAND ACCESS CORRIDOR SHALL BE ALLOWED ONLY OVER UNVEGETATED SEGMENTS OF ISLAND.

PL WA

WA WA WA

198,500 N

1,000'

DATE

6 (TYP) 1

-5

PL

COASTAL ENGINEERING CONSULTANTS, INC. PH: (225) 768-1982 8570 ANSELMO LANE BATON ROUGE, LA 70810

DRAWN BY: STEVE DARTEZ

0

3,472,500 E

3,470,500 E

3,468,500 E

WA

230+W0A0

WA

240+00

WA

250+00

260+00

WA

WA

WA

WA

W

5

45' (MAX)

MLW = -0.37'

200,500 N

PL

TEAW-02 A

45' (MAX)

-10

3,472,500 E

OYS

OYS

WA

EXISTING EL. -5'

MHW = +0.88' 0

EL. = +2.0' (MAX)

EL. = +2.0' (MAX)

WA

OYS

OYS

H

WA

OYS

OYS

10

A

S OY

3,560,500 E

OY

OYS

WA

OYS

PL

OYS

WEST

10

5

EXISTING EL. -4'

PL

H - H'

EAST

202,500 N EXISTING EL. -7'

EXISTING EL. -6'

PL

OYS

DESIGN SCALE: H: 1" = 300' V: 1" = 15'

ELEVATION (NAVD88, FT)

S

OYS

WA

EXISTING EL. -8'

H'

3,468,500 E

EXISTING EL. -9' 3,472,500 E

YS

O

WA WA

OYS

PL

EXISTING GRADE (2016)

PL

202,500 N

PROBABLE PIPELINE (CMD, 2010)

PL

PL

WA

S OY

OYSTER LEASE (LDWF, 2018)

OYS

PL

PL

WORK AREA

209,000 N

TEMPORARY SIDECAST DISPOSAL

PL

TEAW-01

UPLAND CORRIDOR

WA

ACCESS CHANNEL

PL

ACCESS CHANNEL S TEMPORARY OY SIDECAST DISPOSAL S

OYS

LEGEND:

PL

OY OYS

204,500 N

3,472,500 E

204,500 N

3,470,500 E

PL

BEACH CREST

OYS

S OY

3,560,500 E

PL FILL EXTENTS

WA

211,000 N

DESIGNED BY: MICHAEL T. POFF, P.E. LICENSE NUMBER: 30048

LOUISIANA COASTAL PROTECTION AND RESTORATION AUTHORITY 150 TERRACE AVENUE BATON ROUGE, LA 70802

APPROVED BY: TRAVIS BYLAND, P.E.

TERREBONNE BASIN BARRIER ISLAND AND BEACH NOURISHMENT

TRINITY-EAST ISLAND ACCESS CHANNEL - WEST

STATE PROJECT NUMBER: TE-143

DATE: APRIL 2018

FEDERAL PROJECT NUMBER:

SHEET 13 OF 36

LEGEND

3,480,000 E

3,478,000 E

ACCESS CHANNEL

TEAE-01

WA

3,479,000 E

I'

WA

WA

WA

205,000 N

I

5

EXISTING EL. -7'

EXISTING EL. -5' A

WA

W

EXISTING EL. -4' W

A

EXISTING EL. -3'

W

W

A

EXISTING EL. -2'

W

A W

A

WA

W

TEAE-02

A W

W

A

A

A

A W

A

A W

A

WA PL

3,480,000 E

PL

1,000'

500'

0'

-5

170' (MAX)

140' (MAX) 30' BERM (MIN)

150' (MAX)

140' (MAX)

EL.= -9.0'(MAX)

30' BERM (MIN)

-10

-15

-15 -600

0

600

DISTANCE FROM ALIGNMENT (FT)

NOTES: 1. CROSSING OF OIL & GAS PIPELINES SHALL BE IN ACCORDANCE WITH PIPELINE OWNER AND CONSTRUCTION CONTRACTOR CROSSING AGREEMENTS. 2. MATERIAL REMAINING IN THE TEMPORARY SIDECAST DISPOSAL AREAS SHALL BE REWORKED TO ±0.5 FEET OF THE PRE-CONSTRUCTION ELEVATIONS PRIOR TO DEMOBILIZATION. 3. ELEVATIONS IN THE ACCESS CHANNEL RESULTING FROM BACKFILLING OPERATIONS SHALL BE NO HIGHER THAN +0.5 FEET OF THE PRE-CONSTRUCTION ELEVATION. 4. EXISTING GRADE SURVEY PROVIDED BY CPRA AS PART OF THE BARRIER ISLAND COMPREHENSIVE MONITORING PROGRAM, 2016. 5. ALL COORDINATES ARE NAD83, LOUISIANA STATE PLANE, U.S. SURVEY FEET. 6. AERIAL IMAGE REFERENCE: ©2018 MICROSOFT CORPORATION ©2018 DIGITALGLOBE ©CNES (2018) DISTRIBUTION AIRBUS DS; BING. 7. SEE SHEET 34 FOR ALIGNMENT AND COORDINATE TABLES.

WA

W PL

6 (TYP) 1

-10

00 120+

WA

5

45' (MAX)

-5

203,000 N

00 130+

150+00

160+00

WA

WA

PL

10

0

A

WA

PL

EL. = +2.0' (MAX)

45' (MAX)

MLW = -0.37'

A

140+00

PL

WA

MHW = +0.88' 0

EXISTING EL. -1' W

WEST

EL. = +2.0' (MAX)

A

W

W

3,478,000 E

A

EXISTING EL. -6'

3,482,000 E

W W

TEAE-03 203,000 N

I - I'

EAST 10 WA

3,478,000 E

SCALE: H: 1" = 300' V: 1" = 15' WA

209,000 N

DESIGN

WA

WA

PROBABLE PIPELINE (CMD, 2010)

PL

EXISTING GRADE (2016)

EXISTING EL. -9'

EXISTING EL. -8'

WORK AREA

WA

TEMPORARY SIDECAST DISPOSAL

WA

WA WA

TEMPORARY SIDECAST DISPOSAL

ACCESS CHANNEL

WA

BEACH FILL

LEGEND:

207,000 N 3,482,000 E

207,000 N

BEACH CREST

ELEVATION (NAVD88, FT)

FILL EXTENTS

211,000 N

1,000'

PL 201,000 N PL

BY

DESCRIPTION

DATE

COASTAL ENGINEERING CONSULTANTS, INC. PH: (225) 768-1982 8570 ANSELMO LANE BATON ROUGE, LA 70810

DRAWN BY: STEVE DARTEZ

DESIGNED BY: MICHAEL T. POFF, P.E. LICENSE NUMBER: 30048

LOUISIANA COASTAL PROTECTION AND RESTORATION AUTHORITY 150 TERRACE AVENUE BATON ROUGE, LA 70802

APPROVED BY: TRAVIS BYLAND, P.E.

TERREBONNE BASIN BARRIER ISLAND AND BEACH NOURISHMENT

TRINITY-EAST ISLAND ACCESS CHANNEL - EAST

STATE PROJECT NUMBER: TE-143

DATE: APRIL 2018

FEDERAL PROJECT NUMBER:

SHEET 14 OF 36

208,600 N

LEGEND:

3,493,600 E

208,600 N

3,492,000 E

3,490,400 E

208,600 N

ACCESS CHANNEL TEMPORARY SIDECAST DISPOSAL

DESIGN

WA

WA

EXISTING EL. -9'

EXISTING GRADE (2016)

TEDR-01

WA

SCALE: H: 1" = 300' V: 1" = 15'

WA

WA

EXISTING EL. -6' EXISTING EL. -5'

WA WA

WA

TEDR-03

EXISTING EL. -4' WA

WA

TEDR-02

WA

3,490,400 E

WA WA

WA WA

800'

140' (MAX) 30' BERM (MIN)

-10

-15

0'

0

600

DISTANCE FROM ALIGNMENT (FT)

3,493,600 E

203,800 N

400'

150' (MAX) EL.= -9.0'(MAX)

NOTES: 1. CROSSING OF OIL & GAS PIPELINES SHALL BE IN ACCORDANCE WITH PIPELINE OWNER AND CONSTRUCTION CONTRACTOR CROSSING AGREEMENTS. 2. MATERIAL REMAINING IN THE TEMPORARY SIDECAST DISPOSAL AREAS SHALL BE REWORKED TO ±0.5 FEET OF THE PRE-CONSTRUCTION ELEVATIONS PRIOR TO DEMOBILIZATION. 3. ELEVATIONS IN THE ACCESS CHANNEL RESULTING FROM BACKFILLING OPERATIONS SHALL BE NO HIGHER THAN +0.5 FEET OF THE PRE-CONSTRUCTION ELEVATION. 4. EXISTING GRADE SURVEY PROVIDED BY CPRA AS PART OF THE BARRIER ISLAND COMPREHENSIVE MONITORING PROGRAM, 2016. 5. ALL COORDINATES ARE NAD83, LOUISIANA STATE PLANE, U.S. SURVEY FEET. 6. AERIAL IMAGE REFERENCE: ©2018 MICROSOFT CORPORATION ©2018 DIGITALGLOBE ©CNES (2018) DISTRIBUTION AIRBUS DS; BING. 7. SEE SHEET 34 FOR ALIGNMENT AND COORDINATE TABLES.

TEDR-04

3,492,000 E

3,490,400 E

WA

203,800 N

140' (MAX) 30' BERM (MIN)

-15

WA

CHANNEL

TEMPORARY SIDECAST DISPOSAL

-5

170' (MAX)

-600

0 10+0

203,800 NACCESS

6 (TYP) 1

-5

0 20+0

DOCK

5

0

0 30+0

LEGEND

10

45' (MAX)

MLW = -0.37'

0 00+0

EXISTING EL. -1'

MHW = +0.88' 0

EL. = +2.0' (MAX)

45' (MAX)

-10

DOCK WA

205,400 N

3,492,000 W EA

J'

EXISTING EL. -2' WA

205,400 N

EXISTING EL. -3'

WA

EXISTING EL. -7'

WEST

EL. = +2.0' (MAX)

5

WA

EXISTING EL. -8'

J - J'

EAST 10

ELEVATION (NAVD88, FT)

WA

WA

207,000 N

J

3,493,600 E

3,490,400 E

WA

207,000 N

800'

WORK AREA

BY

DESCRIPTION

DATE

COASTAL ENGINEERING CONSULTANTS, INC. PH: (225) 768-1982 8570 ANSELMO LANE BATON ROUGE, LA 70810

DRAWN BY: STEVE DARTEZ

DESIGNED BY: MICHAEL T. POFF, P.E. LICENSE NUMBER: 30048

LOUISIANA COASTAL PROTECTION AND RESTORATION AUTHORITY 150 TERRACE AVENUE BATON ROUGE, LA 70802

APPROVED BY: TRAVIS BYLAND, P.E.

TERREBONNE BASIN BARRIER ISLAND AND BEACH NOURISHMENT

TRINITY-EAST ISLAND DOCK REMOVAL ACCESS CHANNEL

STATE PROJECT NUMBER: TE-143

DATE: APRIL 2018

FEDERAL PROJECT NUMBER:

SHEET 15 OF 36

10 EQUAL SPACES @ 8'-10 9/16" O.C. 10' (TYP.)

8' EL. +7.0' NAVD88 7' (TYP.)

3"x12"x8' C.C.A. TREATED TIMBER DECKING

CLASS "B" TREATED TIMBER PILE LENGTH: 30' (TYP.)

20'

EL. +4.0' NAVD88 MHW = +0.88' NAVD88 MLW = -0.37' NAVD88

4"x8" TREATED TIMBER X-BRACES

8"x12" TREATED TIMBER BOARDS

ELEVATION VIEW TIMBALIER ISLAND DOCK FACILITY NOT TO SCALE

100' 10 EQUAL SPACES @ 8'-10 9/16" O.C. 3"x12"x8' C.C.A. TREATED TIMBER DECKING

SECTION 2-2' DOCK DETAIL (TIMBER) NOT TO SCLAE

2'

19.4'

8'

2

PLAN VIEW

NOTES: 1. DOCK INSTALLED AS PART OF THE ISLE DERNIERES RESTORATION PROJECT - EAST ISLAND - PHASE 0. 2. ALL MATERIALS REMAINING AS PART OF THE DOCK SHALL BE REMOVED AND DISPOSED OF IN AN APPROVED DISPOSAL FACILITY IN ACCORDANCE WITH ALL FEDERAL AND STATE LAWS. 3. ALL PILINGS ASSOCIATED WITH THE DOCK STRUCTURE SHALL BE REMOVED TO A DEPTH OF AT LEAST TEN (10) FEET BELOW EXISTING GROUND. 4. DOCK FASTENING HARDWARE IS COMPRISED OF 7/8" GALVANIZED BOLTS WITH O.G. WASHERS AND NUTS. 5. ELEVATIONS OF CONSTRUCTION ARE ONLY RELEVANT TO THE TIME OF CONSTRUCTION AND MAY NOT REFLECT CURRENT CONDITIONS. 6. DOCK DRAWINGS OBTAINED FROM THE ISLE DERNIERES RESTORATION PROJECT - EAST ISLAND PHASE 0 (TE-20) AS-BUILT DRAWINGS. BY

DESCRIPTION

DATE

NOT TO SCALE

COASTAL ENGINEERING CONSULTANTS, INC. PH: (225) 768-1982 8570 ANSELMO LANE BATON ROUGE, LA 70810

DRAWN BY: STEVE DARTEZ

DESIGNED BY: MICHAEL T. POFF, P.E. LICENSE NUMBER: 30048

LOUISIANA COASTAL PROTECTION AND RESTORATION AUTHORITY 150 TERRACE AVENUE BATON ROUGE, LA 70802

APPROVED BY: TRAVIS BYLAND, P.E.

TERREBONNE BASIN BARRIER ISLAND AND BEACH NOURISHMENT

TRINITY-EAST ISLAND DOCK REMOVAL DETAIL

STATE PROJECT NUMBER: TE-143

DATE: APRIL 2018

FEDERAL PROJECT NUMBER:

SHEET 16 OF 36

AA

AA

LEGEND

DESIGN CUT TOE

PL AA

BATHYMETRIC CONTOUR (OSI, 2015)

PL OSI-15-VC-1 AA

PL

AA AA

3,499,200 E

AA

AA

3,496,800 E

AA

AA

OSI-15-VC-2

PL PL

150,200 N

PL AA

SS-02

PL

PL

AA

AA

PL AA

SS-04

AA AA

AA

OSI-15-VC-16

PL

OSI-15-VC-25 AA

AA

OSI-15-VC-10

AA

OSI-15-VC-7

PL

OSI-15-VC-26

OSI-15-VC-19

AA

SS-08

147,800 N

AA

3,492,000 E

AA

AA

AA

PL

K'

OSI-15-VC-20

OSI-15-VC-13 OSI-15-VC-4

AA

AA

OSI-15-VC-18

SS-07

OSI-15-VC-9

AA

SS-03

3,016,000 E

AA

AA

OSI-15-VC-15 OSI-15-VC-3

ALLOWABLE ANCHOR AREA

AA

AA

L'

OSI-15-VC-12 OSI-15-VC-6

SS-09

CONVEYANCE CORRIDORS

150,200 N

AA

AA

OSI-15-VC-8

SS-11 SS-10

AVOIDANCE AREAS (OSI, 2015) 2015 SURVEY LIMITS

PL

M'

150,200 N

DESIGN CUT: -37FT MAX DISTURBANCE -40FT

PL AA

OSI-15-VC-5

AA

AA

3,492,000 E

PIPELINES (OSI, 2015) AA

AA

N'

DESIGN CUT: -40FT MAX DISTURBANCE: -43FT

147,800 N

AA

AA

PL

PL

AA

AA

OSI-15-VC-1

VIBRACORE (OSI, 2015) AA

AA

SS-01

DESIGN CUT: -36FT MAX DISTURBANCE: -39FT

AA

PL

DESIGN CUT: -38FT MAX DISTURBANCE: -41FT

AA

2015 SURVEY LIMITS

DESIGN CUT: -35FT MAX DISTURBANCE: -38FT

SS-05

OSI-15-VC-14 OSI-15-VC-23

OSI-15-VC-11

OSI-15-VC-30

OSI-15-VC-24

OSI-15-VC-21 OSI-15-VC-29

OSI-15-VC-17

AA

SS-07

OSI-15-VC-22

SS-06

600'

0'

BY

DESCRIPTION

AA

AA

AA

AA

AA

AA

SURVEY AA BASELINE

AA

AA

SSBL-01

AA

PL

AA

00+00

PL

04+00

08+00

12+00

PL 3,016,000 E

145,400 N

16+00

20+00

32+00

36+00

40+00

44+00

145,400 N

24+00

K 48+00

60+00

64+00

68+00

145,400 N

145,400 N

NOTES: 1. GEOPHYSICAL, GEOTECHNICAL, AND PIPELINE DATA FROM OSI, 2015. 2. ELEVATIONS ARE NAVD88, U.S. SURVEY FEET. 3. COORDINATES ARE NAD83, LA STATE PLANE, U.S. SURVEY FEET. 4. SEE SHEET 35 FOR ALIGNMENT AND COORDINATE TABLES. 5. CURRENTLY PERMITTED UNDER C.U.P. NO. P20170043 AND C.O.E. NO. MVN 2015-0895-CQ.

1,200' DATE

COASTAL ENGINEERING CONSULTANTS, INC. PH: (225) 768-1982 8570 ANSELMO LANE BATON ROUGE, LA 70810

DRAWN BY: STEVE DARTEZ

AA

28+00

AA

3,499,200 E

AA

L 72+00

80+00

84+00

145,400 N

1,200'

OSI-15-VC-27

OSI-15-VC-28

AA

M 88+00

92+00

96+00

100+00

3,492,000 E

104+00

108+00

N

AA

52+00

AA

3,496,800 E

AA

56+00

AA

76+00

AA

3,494,400 E

AA

AA

AA AA

SSBL-02

AA

AA

DESIGNED BY: MICHAEL T. POFF, P.E. LICENSE NUMBER: 30048

LOUISIANA COASTAL PROTECTION AND RESTORATION AUTHORITY 150 TERRACE AVENUE BATON ROUGE, LA 70802

APPROVED BY: TRAVIS BYLAND, P.E.

TERREBONNE BASIN SHIP SHOAL BORROW AREA BARRIER ISLAND AND BEACH PLAN VIEW NOURISHMENT STATE PROJECT NUMBER: TE-143

DATE: APRIL 2018

FEDERAL PROJECT NUMBER:

SHEET 17 OF 36

EXISTING GRADE (2015)

DESIGN DREDGE CUT

100H:1V PIPELINE SLOPE OFFSET

DESIGN LIMIT OF DISTURBANCE

VC-24

LEGEND:

NOTES: 1. GEOPHYSICAL AND GEOTECHNICAL DATA FROM OSI, INC., 2015. 2. ELEVATIONS ARE SHOWN IN NAVD88 U.S. SURVEY FEET. 4. MEAN HIGH WATER = +0.88FT NAVD88, MEAN LOW WATER = -0.37 FT NAVD88.

VIBRACORE (2015)

SCALE: H: 1" = 500' V: 1" = 25'

SOUTH

NORTH -15

K - K'

-20

-25

VC-26

-20

VC-22

ELEVATION (FT, NAVD88)

-15

-30 -35

-30 -35

-38FT

-40FT

-41FT

-40

-25

-43FT

-40 -45

-45

-50 2500

-50 0

500

1000

1500

2000

DISTANCE FROM BASELINE (FEET)

SOUTH

NORTH -15

L - L'

-25 -30 -35

-25 -30 -35FT

-37FT

-38FT

-40FT

-40

VC-15

-20 VC-16

-20

VC-17

ELEVATION (FT, NAVD88)

-15

-38FT

-41FT

-35 -40 -45

-45

-50

-50 0

500

1000

1500

2000

2500

3000

3500

DISTANCE FROM BASELINE (FEET)

BY

DESCRIPTION

DATE

COASTAL ENGINEERING CONSULTANTS, INC. PH: (225) 768-1982 8570 ANSELMO LANE BATON ROUGE, LA 70810

DRAWN BY: STEVE DARTEZ

DESIGNED BY: MICHAEL T. POFF, P.E. LICENSE NUMBER: 30048

LOUISIANA COASTAL PROTECTION AND RESTORATION AUTHORITY 150 TERRACE AVENUE BATON ROUGE, LA 70802

APPROVED BY: TRAVIS BYLAND, P.E.

TERREBONNE BASIN SHIP SHOAL BORROW AREA BARRIER ISLAND AND BEACH TYPICAL SECTIONS NOURISHMENT STATE PROJECT NUMBER: TE-143

DATE: APRIL 2018

FEDERAL PROJECT NUMBER:

SHEET 18 OF 36

VC-24

LEGEND:

NOTES: 1. GEOPHYSICAL AND GEOTECHNICAL DATA FROM OSI, INC., 2015. 2. ELEVATIONS ARE SHOWN IN NAVD88 U.S. SURVEY FEET. 4. MEAN HIGH WATER = +0.88FT NAVD88, MEAN LOW WATER = -0.37 FT NAVD88.

EXISTING GRADE (2015)

DESIGN DREDGE CUT

100H:1V PIPELINE SLOPE OFFSET

DESIGN LIMIT OF DISTURBANCE

VIBRACORE (2015)

SCALE: H: 1" = 500' V: 1" = 25'

SOUTH

NORTH -15

M - M'

-30 -35

VC-9

-25

VC-8

-20 VC-10

-20

VC-11

ELEVATION (FT, NAVD88)

-15

-30 -35FT

-37FT

-38FT

-40FT

-40

-25

-35

-38FT

-41FT

-40 -45

-45 -50 0

500

1000

1500

2000

2500

3000

3500

-50 4500

4000

DISTANCE FROM BASELINE (FEET)

SOUTH

NORTH -15

-30 -35

VC-6

-25

-20

VC-5

N - N' VC-7

-20

VC-29

ELEVATION (FT, NAVD88)

-15

-25 -30

-36FT

-35FT

-37FT

-39FT

-38FT

-40FT

-40

-38FT

-41FT

-40 -45

-45 -50 0

-35

-50 500

1000

1500

2000

2500

3000

3500

4000

4500

DISTANCE FROM BASELINE (FEET) BY

DESCRIPTION

DATE

COASTAL ENGINEERING CONSULTANTS, INC. PH: (225) 768-1982 8570 ANSELMO LANE BATON ROUGE, LA 70810

DRAWN BY: STEVE DARTEZ

DESIGNED BY: MICHAEL T. POFF, P.E. LICENSE NUMBER: 30048

LOUISIANA COASTAL PROTECTION AND RESTORATION AUTHORITY 150 TERRACE AVENUE BATON ROUGE, LA 70802

APPROVED BY: TRAVIS BYLAND, P.E.

TERREBONNE BASIN SHIP SHOAL BORROW AREA BARRIER ISLAND AND BEACH TYPICAL SECTIONS NOURISHMENT STATE PROJECT NUMBER: TE-143

DATE: APRIL 2018

FEDERAL PROJECT NUMBER:

SHEET 19 OF 36

AA

CEC-11-VC-1

Q AA

AA AA

AA AA

AA

AA

PL

AA

PL

AA

AA AA

AA

AA

PL

CHVC-05-13 SP-06

0 +0 24

PL

AA

PL

0 +0 16

AA

AA

SP-02

AA

PL

CHVC-05-12 AA

AA

AA

AA AA

AA

AA

AA AA

AA

P

147,000 N

EXPANSION AREA - A

0 +0 88

AA

3,505,000 E

AA

0 +0 72

0 +0 80

AA AA AA

PL

PL

PL

SP-05

0 +0 96

PL

PL

PL

LEGEND

10

DESCRIPTION

00 4+

BY

00 2+

0'

PL

750'

11

PL

1,500'

SPBL-02

1,500' DATE

DESIGN CUT TOE

DESIGN CUT: -40FT MAX DISTURBANCE: -43FT

BA-143 BORROW AREA

DESIGN CUT: -42FT MAX DISTURBANCE -45FT

2011 SURVEY LIMITS

DESIGN CUT: -44FT MAX DISTURBANCE: -47FT

COASTAL ENGINEERING CONSULTANTS, INC. PH: (225) 768-1982 8570 ANSELMO LANE BATON ROUGE, LA 70810

DRAWN BY: STEVE DARTEZ

SURVEY BASELINE

0 +0 64

PL

PL

PL

147,000 N

CAMINADA HEADLAND BEACH AND DUNE RESTORATION (BA-143) PERMITTED BORROW AREA (MVN-2012-02134-WPP, P20121150)

0 +0 56

PL

PL

O

0 +0 48

AA AA

SP-04

3,515,000 E

PL

AA

AA

AA

0 +0 40

PL

PL

AA

AA

AA

0 +0 32

AA

CEC-12-VC-5

PL

SPBL-01

AA

O'

AA

PL

0 +0 08

AA

PL

AA

AA

PL

0 +0 00

AA

SP-03

PL

152,000 N

AA

AA

AA

SP-01

PL

AA

AA

AA

AA

AA

AA

AA

AA

PL

SP-11

AA

CEC-12-VC-7

AA

SP-10

CEC-12-VC-3

PL

3,515,000 E

AA

AA

AA

R

P'

AA

AA

AA

AA

PL

PL

AA

AA

AA

152,000 N

AA

PL

SP-08

SP-12 PL

AA

PL

Q'

AA

AA

3,505,000 E

R' AA

SP-09 AA CEC-11-VC-2A

AA

2011 SURVEY LIMITS

AA

AA

AA

SP-07

AA

PL

EXPANSION AREA - B

DESIGNED BY: MICHAEL T. POFF, P.E. LICENSE NUMBER: 30048

LOUISIANA COASTAL PROTECTION AND RESTORATION AUTHORITY 150 TERRACE AVENUE BATON ROUGE, LA 70802

APPROVED BY: TRAVIS BYLAND, P.E.

NOTES: 1. GEOPHYSICAL AND GEOTECHNICAL DATA FROM OSI, 2011-12 AND GEOTECHNICAL DATA FROM CPE, 2005. 2. ELEVATIONS ARE NAVD88, US SURVEY FEET. 3. COORDINATES ARE NAD83, LA STATE PLANE, US SURVEY FEET. 4. SEE SHEET 35 FOR ALIGNMENT AND COORDINATE TABLES. 5. CURRENTLY PERMITTED UNDER C.U.P. NO. P20170043 AND C.O.E. NO. MVN 2015-0895-CQ.

-34

BATHYMETRIC CONTOUR (OSI 2011) CONVEYANCE CORRIDORS

AA

PL

ALLOWABLE ANCHOR AREA PIPELINES (OSI, 2011)

TERREBONNE BASIN BARRIER ISLAND AND BEACH NOURISHMENT

SOUTH PELTO BORROW AREA PLAN VIEW

STATE PROJECT NUMBER: TE-143

DATE: APRIL 2018

FEDERAL PROJECT NUMBER:

SHEET 20 OF 36

LEGEND: SCALE: H: 1" = 500' V: 1" = 25'

DESIGN DREDGE CUT

EXISTING GRADE (2011)

DESIGN LIMIT OF DISTURBANCE

VIBRACORE (CEC-12-VC-1, OSI 2012) (CHVC-05-12, CPE 2005)

ELEVATION (FT, NAVD88)

NOTES: 1. GEOPHYSICAL AND GEOTECHNICAL DATA FROM OSI, 2011. 2. ELEVATIONS ARE SHOWN IN NAVD88 U.S. SURVEY FEET. 3. MEAN HIGH WATER = +0.88FT NAVD88, MEAN LOW WATER = -0.37 FT NAVD88. -15

SOUTHEAST

NORTHWEST

O - O'

-20

-15 -20 -25

-25 -30

-30

CHVC-05-12

-35

-35 -40FT -43FT

1 (TYP) 3

-40 -45 -50 0

500

-42FT -45FT

-40

-44FT -47FT

1000

1500

2000

2500

3000

3500

-45 -50 4500

4000

ELEVATION (FT, NAVD88)

DISTANCE ALONG PROFILE (FEET)

-15

SOUTHEAST

-20

NORTHWEST

P - P'

-20

-25

-25

-30

CEC-12-VC-7

CEC-12-VC-5

CHVC-05-12

-30

-35 -40 -45 -50 0

-15

-35 1 (TYP) 3

-42FT -45FT

-44FT -47FT 500

1000

1500

-40FT -43FT

2000

2500

3000

-40 -45

3500

-50 4500

4000

DISTANCE ALONG PROFILE (FEET) BY

DESCRIPTION

DATE

COASTAL ENGINEERING CONSULTANTS, INC. PH: (225) 768-1982 8570 ANSELMO LANE BATON ROUGE, LA 70810

DRAWN BY: STEVE DARTEZ

DESIGNED BY: MICHAEL T. POFF, P.E. LICENSE NUMBER: 30048

LOUISIANA COASTAL PROTECTION AND RESTORATION AUTHORITY 150 TERRACE AVENUE BATON ROUGE, LA 70802

APPROVED BY: TRAVIS BYLAND, P.E.

TERREBONNE BASIN BARRIER ISLAND AND BEACH NOURISHMENT

SOUTH PELTO BORROW AREA TYPICAL SECTIONS

STATE PROJECT NUMBER: TE-143

DATE: APRIL 2018

FEDERAL PROJECT NUMBER:

SHEET 21 OF 36

LEGEND: SCALE: H: 1" = 500' V: 1" = 25'

EXISTING GRADE (2011)

DESIGN DREDGE CUT

VIBRACORE (CEC-11-VC-1, OSI 2011)

DESIGN LIMIT OF DISTURBANCE

ELEVATION (FT, NAVD88)

NOTES: 1. GEOPHYSICAL AND GEOTECHNICAL DATA FROM OSI, 2011. 2. ELEVATIONS ARE SHOWN IN NAVD88 U.S. SURVEY FEET. 3. MEAN HIGH WATER = +0.88FT NAVD88, MEAN LOW WATER = -0.37 FT NAVD88. -15

SOUTHWEST

NORTHEAST

Q - Q'

-20 -25

-15 -20 -25

CEC-11-VC-2A

CEC-11-VC-1

-30

-30

1 3 (TYP)

-35 -40

-42FT -45FT

-44FT -47FT

-45 -50 0

500

1000

1500

-35

-40FT -43FT

-40 -45

2000

2500

3000

3500

-50 4500

4000

ELEVATION (FT, NAVD88)

DISTANCE ALONG PROFILE (FEET)

-15

SOUTHEAST

-20

NORTHWEST

R - R'

-25

-20 -25

CEC-11-VC-1

-30

-30

1 3 (TYP)

-35 -40

-35 -40

-44FT -47FT

-45 -50 0

-15

500

1000

-45

1500

2000

2500

3000

3500

-50 4500

4000

DISTANCE ALONG PROFILE (FEET) BY

DESCRIPTION

DATE

COASTAL ENGINEERING CONSULTANTS, INC. PH: (225) 768-1982 8570 ANSELMO LANE BATON ROUGE, LA 70810

DRAWN BY: STEVE DARTEZ

DESIGNED BY: MICHAEL T. POFF, P.E. LICENSE NUMBER: 30048

LOUISIANA COASTAL PROTECTION AND RESTORATION AUTHORITY 150 TERRACE AVENUE BATON ROUGE, LA 70802

APPROVED BY: TRAVIS BYLAND, P.E.

TERREBONNE BASIN BARRIER ISLAND AND BEACH NOURISHMENT

SOUTH PELTO BORROW AREA TYPICAL SECTIONS

STATE PROJECT NUMBER: TE-143

DATE: APRIL 2018

FEDERAL PROJECT NUMBER:

SHEET 22 OF 36

PL

PL

PL PL

PL

PL

PL

PL

ST09 ST10

ST16

OCS LEASE BOUNDARY

PL

PROBABLE PIPELINE (OSI, 2011, CMD, 2010, & BOEM, 2007)

PL

PL

PL PL PL

PL

PL

PL

PL

PL

TIMBALIER CONVEYANCE PL CORRIDOR 8.34 NM

PL

PL PL

PL

PL

PPLL

PL PL

PL PL

PL P PL L PL

PL

PPL L

PL

PL PL

PL

TERREBONNE BASIN BARRIER ISLAND AND BEACH NOURISHMENT

PL

PPL L PL

PL

PL PL PL PL PPL LPL

PL PL

PL PL

PL

PL

PLPL PLPL

PL

PL

PL

PL

PL

PL

PL PL

PL

PL

PL

PL

PL

PL

PL PL

PL

PL

PL

PL

PL PPL L

PL PL

PL

PL

PL PL

PL

PL

PL

PL PL

PL

PPL L PL

PL

PL

PL

PL

PL

PL

PL

PL

PL

PL

PL

PL

PL PL

PL

PL

PL

PL

PL

PL

PL

PL

PL

PL

PL

PL

PLPL PLPL

PPL L

PL

PL

P PPL L LPL PLPL

PL

PL

PL PL

PL

PL

PL

PL

PL PPL L

PL

PL

PL

PLPL

PL

PL

PL PL PL PL PPLL PL

PLPL PL PL

PL

APPROVED BY: TRAVIS BYLAND, P.E.

PL

150 TERRACE AVENUE BATON ROUGE, LA 70802

PL

PL

PL PL

DESIGNED BY: MICHAEL T. POFF, P.E. LICENSE NUMBER: 30048

LOUISIANA COASTAL PROTECTION AND RESTORATION AUTHORITY

PL

PL

PL

PL PL

NOTES: 1. SEE SHEET 36 FOR ALIGNMENT AND COORDINATE TABLES.

COASTAL ENGINEERING CONSULTANTS, INC.

PL PL

PL PL PL PL

PL

PL

PL

PL

PL

PL

3.05 NM

PL PL

PL PL PPLLPL

PL

PL

PL

PL

PL

PL

PL PPPLLL

PL

PL

PL

PL

PL PL PL

PL

PL

PL PL

TIMBALIER BAY

PL

PL

PL

PL

L PL PPL

PL

PL

PL

PL

1.44 NM

DETAIL ON SHEET 25

DATE

PL

PL

PL

ST32 ST35

PL

PL

10,000'

PL

PL

PL TIMBALIER PUMP-OUT PLL AREA NO. 2 P PL

PL

PL

PL

PH: (225) 768-1982 8570 ANSELMO LANE BATON ROUGE, LA 70810

DRAWN BY: STEVE DARTEZ

PL

PL

PL

PL

PL

PL PPPLLL

DESCRIPTION

PL

PL

PL

ST50

PL

PL

PL

PL

PL

PPPLLL

PL PLPLL

PL

TIMBALIER PUMP-OUT AREA NO. 1

PL PL

PL

PL

PL

ST33 ST34

PL

PL PL PL

BY

PL

PL

PLPL 0'

PL PL PL

PL

PL

PL

PL

PL

PL

5,000'PLPL

PL

PL PL PL L PL

PL

PL

L

PL

PL

PL

PL

PL

PL P PLL

PL

PL

PL

PL

PLP

PL

P

ST53

10,000'

PL

PL PLP L

PPL PL L

PL PLL PPL

PLPL

PL PLP L PL PLPL P PLL

TIMBALIER ISLAND

PL

PL

PPLL

ST51

ST52 PL P PL L

PL

PL

PL

PL

PL

PL PL

PL

PL

PL

PL

PL PL

PL

PL

PL PL

PL

PL

PL

PL

PL

PL

PL

PL

PL

PL

PL

PL

PL

PL

GULF OF MEXICO

PL

PL

PL PL P L

PL

PL

PL

PL

PL

PL

PL

PL

PL

PL

PL

PL

PL

PL

PL

PL

PL

PL

PL

PL

PL

PL

PL

PL

PL

PL

L

PL

PL

PL

PL

PPLL

PL

PL

ST11

ST05 SP06

PL

PL

PL

SP15 SP16

PL

PL

DETAILP ON L SHEET 24

FEDERAL / STATE WATER BOUNDARY

PL

PL

PL

CONVEYANCE CORRIDOR ALIGNMENT

PL

PL

ST03 ST04 SP08 SP07

SP13 SP14 SP18 SP17

PL

PL

PL

PL

PL

PL

PL

PL

PL

PL

BORROW AREA LIMITS PL

PL

PL

PL

PL

PL

PL

P PL

PL

PL

PL

PL

PL

PL

PL

SOUTH PELTO BORROW AREAS

PL

PL

PL

PL PL

PUMP-OUT AREA LIMITS PL L

PL

PL

PL

SHIP SHOAL BORROW AREA

PL

PL PL

0.78 NM PL

PL

PL

PL

ISLAND NOURISHMENT AREA LIMITS

PL

PL

PLP L

PL

PL PL

PL

PL

PL

LEGEND

PL

PL

SP03 SP08

PL

PL

TIMBALIER PUMP-OUT AREAS & CONVEYANCE CORRIDORS OVERVIEW

STATE PROJECT NUMBER: TE-143

DATE: APRIL 2018

FEDERAL PROJECT NUMBER:

SHEET 23 OF 36

PL

PL

PL

PL

PL

PL

PL

PL

PL

AA

PL

PL

AA AA AA AA

PL

SOUTH PELTO BORROW AREAS

PL

AA

AA

PL

PL

AA

PL

AA

PL

AA

PL

PL

TBCC-03B AA

AA

PL

AA

AA

AA

PL

PL

PL

PL

AA

PL

AA

AA

TBCC-03A

AA

PL

PL PL PL

PL

PL

AA

AA

PL

PL

PL

AA

PL

PL

PL

PL

AA

P

PL

AA

TBCC-02 L

PL

PL

PL PL

PL

NOTES: 1. ELEVATIONS FROM NOAA NAUTICAL CHART 11357 "TIMBALIER AND TERREBONNE BAYS", 43rd EDITION, MAY 2014, NOS SURVEYS 1990-2011 RELATIVE TO MEAN LOWER LOW WATER. 2. ALLOWABLE ANCHOR AREA EXTENDS 250 FT BEYOND THE LIMITS OF THE CONVEYANCE CORRIDORS AND BORROW AREAS. 3. SEE SHEET 36 FOR ALIGNMENT AND COORDINATE TABLES.

PL

PL

EXISTING EL. -34'

PL

PL

PL

AA

500 FT

TIMBALIER CONVEYANCE CORRIDOR

PL

PL

PL

PL

PL

PL

PL PL

PL

AA

PL

L

L

SHIPP SHOAL P PL BORROW PL AREA L P

PL

TBCC-01

PL

PL

PL PL

PL

PL

PL

PL

PL

AA

SP14

PL AA

AA

PL

TBCC-06

PL

EXISTING EL. -29'

AA

PL

AA

PL PL

AA

PL

PL

AA

AA

PL

SP17

PL

EXISTING EL. -28'

ST04

PL

TBCC-05

ST03

AA

SP07

TBCC-04

SP08

PL

AA

SP13

PL

SP18

PL

AA

EXISTING EL. -29'

AA AA

PL

AA AA

PL

AA PL

AA

PL

AA

PL ALLOWABLE ANCHOR AREA

PL

SP16 DATE

SP15

CONTINUED ON SHEET 25

COASTAL ENGINEERING CONSULTANTS, INC. PH: (225) 768-1982 8570 ANSELMO LANE BATON ROUGE, LA 70810

DRAWN BY: STEVE DARTEZ

DESIGNED BY: MICHAEL T. POFF, P.E. LICENSE NUMBER: 30048

LOUISIANA COASTAL PROTECTION AND RESTORATION AUTHORITY 150 TERRACE AVENUE BATON ROUGE, LA 70802

APPROVED BY: TRAVIS BYLAND, P.E.

AA

DESCRIPTION

5,000'

AA

PL

0'

BY

AA

2,500'

EXISTING EL. -41'

AA

PROBABLE PIPELINE (CMD, 2010 & BOEM, 2007) PL

5,000'

PL

AA

PL

PL

TIMBALIER CONVEYANCE CORRIDOR

AA

PL

TIMBALIER CONVEYANCE CORRIDOR COORDINATE

PL

EXISTING EL. -37' AA

OCS LEASE BOUNDARY

PL

AA

PL

CONVEYANCE CORRIDOR

TBCC-01

PL

AA

BORROW AREA LIMITS

ST03

PL

AA

LEGEND

AA

PL

PL

500 FT

SP06

TERREBONNE BASIN BARRIER ISLAND AND BEACH NOURISHMENT

TIMBALIER PUMP-OUT AREAS & CONVEYANCE CORRIDORS PLAN VIEW

STATE PROJECT NUMBER: TE-143

DATE: APRIL 2018

FEDERAL PROJECT NUMBER:

SHEET 24 OF 36

CONTINUED FROM SHEET 24 PL

PL

PL

PL PL

AA

PL

PL

PL

PL

PL

PL

PL

PL

PL

PL

PL

PL

PL

PL

PL

PL PL

PL

PL PL PL PL PL

PL PL

AA

AA

AA

AA

AA AA

TIMBALIER PUMP-OUT AREA NO. 2

PL PL

PL PL

PL PL

TIMBALIER CONVEYANCE CORRIDOR

PL

EXISTING EL. -13' PL

PL PL

PL

PL

PL

AA

PLPL PL

PL PL

PL

PL

AA

PL

AA AA

PL

PL

PL PL

PL

AA

AA

PL AA

AA

PL

AA

AA

AA

AA

PL

PL

PLPL

AA

PL

PL

PL

PL PL PL PL

EXISTING EL. -25'

PL PL

EXISTING EL. -22'

AA

AA

AA

PL

TBPO-07

AA

PL

EXISTING EL. -30'

AA

PL

TBCC-11PL

PL AA

AA

AA

PL

PL

500 FT

PL

AA

PL

EXISTING EL. -10'

PL

PL

AA

AA

PL

AA

AA AA

PL

AA

PL

AA

PL

PL

PL

PL

PL

COASTAL ENGINEERING CONSULTANTS, INC.

DESIGNED BY: MICHAEL T. POFF, P.E. LICENSE NUMBER: 30048

PL

PL

PL

PL

PL

NOTES: 1. ELEVATIONS FROM NOAA NAUTICAL CHART 11357 "TIMBALIER AND TERREBONNE BAYS", 43rd EDITION, MAY 2014, NOS SURVEYS 1990-2011 RELATIVE TO MEAN LOWER LOW WATER. 2. ALLOWABLE ANCHOR AREA EXTENDS 250 FT BEYOND THE LIMITS OF THE CONVEYANCE CORRIDORS AND PUMP-OUT AREAS. 3. SEE SHEET 36 FOR ALIGNMENT AND COORDINATE TABLES. DATE

PL

TBPO-08 2000 FT

PH: (225) 768-1982 8570 ANSELMO LANE BATON ROUGE, LA 70810

DRAWN BY: STEVE DARTEZ

PL

PL

DESCRIPTION

5,000'

PL

BY

PL

0'

PL

2,500' PL

5,000'

PL

PL

ALLOWABLE ANCHOR AREA

AA

AA

TBCC-09

PL

PROBABLE PIPELINE (CMD, 2010 & BOEM, 2007)

PL

AA

ST17

ST32

PL

TBCC-01

TBPO-06 TBCC-10 AA

2000 FT

PL

EXISTING EL. -16'

AA

PL

500 FT

TIMBALIER PUMP-OUT AREA COORDINATE TIMBALIER CONVEYANCE CORRIDOR COORDINATE PL

TBPO-01

PL

AA

PL

EXISTING EL. -36'

PL

PL

PL

EXISTING EL. -32'

TBPO-05

OCS LEASE BOUNDARY

ST16

PL

PL

TIMBALIER CONVEYANCE CORRIDOR

AA

PL

TBCC-08

CONVEYANCE CORRIDOR

PL

PL

TBPO-03

PUMP-OUT AREA LIMITS PL PL

PL ST11

PL

AA

TBPO-04

PL

GULF OF MEXICO

EXISTING EL. -39'

AA

PL ISLAND NOURISHMENT PL AREA LIMITS

L

PL

AA

PL

PL

PL

TBPO-02

TBPO-01

TIMBALIER PUMP-OUT AREA NO. 1

PLP

TIMBALIER ISLAND

2000 FT

TBCC-07

2000 FT

PL

ST16

AA

PL

PL

PL

PL

ST33

AA

ST33

PL

PL

PL

PL

PL

PL

PL

PPL L

AA

PL

PL

LEGEND

PL

PL

PL

PL

PL

EXISTING EL. -40'

AA

PL PL

PL

AA

PL

PL

PL

PL

PL

PL

AA

PL

PL

PL

PL

PLPL

FEDERAL / STATE WATER BOUNDARY

PL PL

PL

PL

PL PL

TIMBALIER CONVEYANCE PL PL CORRIDOR PL PL PL

PL

PL

EXISTING EL. -40'

PL

PL

PL

PL PL

PL

PL

PL

AA

PL

AA

PL

PL

PL

PL

PL

PL

PL

PL

PL

PL

PL

PL

PL

PL

500 FT

PL

PL

PL PL

PL

PL

AA

PL

PL

PL

PL

PL

PL

PL

PL

PL

PL

PL

PL

PL

PL

PL

PL

PL

PL

PL PL

PL

PL

PL

AA AA

AA

PL

PL

PL

PL

PL PL

PL

AA

EXISTING EL. -41'

SP05

SP06

AA

SP15

AA

P PL

PL

PL

LOUISIANA COASTAL PROTECTION AND RESTORATION AUTHORITY 150 TERRACE AVENUE BATON ROUGE, LA 70802

APPROVED BY: TRAVIS BYLAND, P.E.

TERREBONNE BASIN BARRIER ISLAND AND BEACH NOURISHMENT

PL

TIMBALIER PUMP-OUT AREAS & CONVEYANCE CORRIDORS PLAN VIEW

STATE PROJECT NUMBER: TE-143

DATE: APRIL 2018

FEDERAL PROJECT NUMBER:

SHEET 25 OF 36

PL

PL

PL

PL

PL

PL

PL

PL

PL

PL PL

PL

PL

PL

PL

PL PLPPL PL L

DESIGNED BY: MICHAEL T. POFF, P.E. LICENSE NUMBER: 30048

PPLL

PL

LOUISIANA COASTAL PROTECTION AND RESTORATION AUTHORITY 150 TERRACE AVENUE BATON ROUGE, LA 70802

APPROVED BY: TRAVIS BYLAND, P.E.

PL

PL LL PP PL PL

LEASE BOUNDARY PL PL

TERREBONNE BASIN BARRIER ISLAND AND BEACH NOURISHMENT

PL

PL

PL

NOTES: 1. SEE SHEET 36 FOR ALIGNMENT AND COORDINATE TABLES.

COASTAL ENGINEERING CONSULTANTS, INC.

PL POCS L

PP LL

PL

PL

L PPL

PL

PL PL

PL

PL

PL

PL

PL

PL PL

PL

PL

PL

PL PL

PL

PL

PL

PL

PL

PL

PL

PL

PL

PL

PL

PL

PL

PL

PL PL PL PL

PL PL

PL

PLPL PL

PL PL

PL

PL

PL

PL

PL

PL

PL PL

PL

PL PL

PL

PL PL

PL PL

PL

PL PL

PL

PL

PL

PL

PL PL

PL

PL

PL PL

PL

PL PL P L

PL

PL

PL

PL

PL

PLPL

PL

PL

ST16

PL

8,000'

CONVEYANCE CORRIDOR ALIGNMENT PL

PL PL

PL

PL PL

PL

BORROW AREA LIMITS PL

GULF OF MEXICO

PL

L

PL

PL

PL

PL

PL

PL LL PP

PL

PUMP-OUT AREA LIMITSPL P PL

PL

PL

PL

PL

PL

PL PL PL

P PL PL L

PL L PL P

DETAIL ON SHEET 27

PL

PPLL

PL PL

PL

PL

PL

PL PL PL

PL

PL

PL PL

PL

ISLAND NOURISHMENT AREA LIMITS

PL PL

PL

P PL L

LEGEND

L PL P

PL

PL PL PL

PL

TRINITY-EAST CONVEYANCE CORRIDOR PL

PL

DATE

PL

PL L P PL

DETAIL ON SHEET 28

PL PL

PL

PL

SP02 SP03

DESCRIPTION

LAKE PELTO

PL

PL

PL

PH: (225) 768-1982 8570 ANSELMO LANE BATON ROUGE, LA 70810

DRAWN BY: STEVE DARTEZ

PL

PL

PL

SP09 SP08

PL

PL

SP13

0'

PL PL

TRINITY-EAST ISLAND

PL

PL

PL

PL

BY

PL PL L P

1.25 NM

PL

PL

PL PL

4.19 NM

PL

PL

SP18

4,000'

PLP L

PL PL

PL PL

TRINITY-EAST PUMP-OUT AREA NO. 2

PL

PL

PL PL

PL

PL

PL

PL

PL

PL

PL

PL

PL

L PLP PL

PL

3.47 NM

PL

PL

PL

PL

PL

PL PL

PLP L

PL PL

PL

PL

PL

PL

PL

SP12

SP19

PL

PL

PL

PL PL

FEDERAL / STATE WATER BOUNDARY

PL

SHIP SHOAL PL BORROW AREA

PL

SP01

PLL P PL

PL

PL

P PL

PL

PL

TRINITY-EAST PUMP-OUT AREA NO. 1

PL PL

P L PL

PL

PL

PL PL

PL

PL

8,000'

SP10

PL

PL PL

PL PL

PL

PL PL

PL

PL

L PPL

PL PLL P

PL

PL

PL

PL

PL PL

PL

PL

SS67

PL

PL

PL

PL

PL

PL

SS68

PL

PL

SS91 SP11 SS92 SP20

PL

PL PL

PL

PL PL

PPLL PL L P

PL PL

PL

PL

PL

PL

PL

PPL L

PL

PL

PL

PL

PROBABLE PIPELINE PLPL (CMD, 2010 & BOEM, 2007)

TRINITY-EAST PUMP-OUT AREAS & CONVEYANCE CORRIDORS OVERVIEW

STATE PROJECT NUMBER: TE-143

DATE: APRIL 2018

FEDERAL PROJECT NUMBER:

SHEET 26 OF 36

PL

PL

PL

PL

PL

PL PL

PL

PL PL

PL

AA

PL

PL

PL

PL

PL

PL

PL PL

PL

PL

PL

TEPO-04

PL

AA AA

PL

PL

PL

AA

PL

PL

AA

PL

PL

PL

PL PL

AA AA AA

AA

PL

PL

PL

PL

CONTINUED ON SHEET 28

PL

PL

PL

PL

PL PL

PL

PL

PL PL

PL

PL

AA

PL

AA

PL

AA

PL

AA

AA

AA

AA

AA

AA

AA

AA

AA

PL

AA

AA

PL

PL

PL

PL PL

PL

PUMP-OUT AREA LIMITS CONVEYANCE CORRIDOR

PL

PL

PL

PL

SP09

PL

PL

TEPO-01 PL

PL PL

PL

PL

AA AA AA AA

AA

NOTES: 1. ELEVATIONS FROM NOAA NAUTICAL CHART 11357 "TIMBALIER AND TERREBONNE BAYS", 43rd EDITION, MAY 2014, NOS SURVEYS 1990-2011 PL RELATIVE TO MEAN LOWER LOW WATER. PL 2. ALLOWABLE ANCHOR AREA EXTENDS 250 FT BEYOND THE LIMITS OF THE CONVEYANCE CORRIDORS, PUMP-OUT AREAS, AND BORROW AREA. 3. SEE SHEET 36 FOR ALIGNMENT AND COORDINATE TABLES.

TECC-01

PL

DATE

COASTAL ENGINEERING CONSULTANTS, INC. PH: (225) 768-1982 8570 ANSELMO LANE BATON ROUGE, LA 70810

DESIGNED BY: MICHAEL T. POFF, P.E. LICENSE NUMBER: 30048

LOUISIANA COASTAL PROTECTION AND RESTORATION AUTHORITY 150 TERRACE AVENUE BATON ROUGE, LA 70802

APPROVED BY: TRAVIS BYLAND, P.E.

OCS LEASE BOUNDARY TRINITY-EAST PUMP-OUT AREA COORDINATE TRINITY-EAST CONVEYANCE CORRIDOR COORDINATE

PL

PROBABLE PIPELINE (CMD, 2010 & TE-40, 2005 )

AA

ALLOWABLE ANCHOR AREA

PL

3,000' PL

PL

DESCRIPTION

PL

PL

PL

PL

AA

PL

PL

PL

PL

PL

LEGEND BORROW AREA LIMITS

PL PL

PL

PL

PL

AA

PL

PL

PL

SP08

AA AA

PL

PL PL

PL

SP13

PL

SP18

PLPL PL

PL

PL

SP09

PL

PL

PL

PL

SP12

AA

SP19

PL

DRAWN BY: STEVE DARTEZ

2000 FT

PL

AA

EXISTING EL. -27'

PL

BY

AA

TRINITY-EAST CONVEYANCE CORRIDOR

PL

PL

0'

TECC-02

PL

500 FT

PL

PL

1,500'

AA

AA AA

AA

AA

TEPO-03

PL

PL

TECC-03

TRINITY-EAST PUMP-OUT AREA NO. 1

PL

PL

AA AA

AA

AA

PL AA AA

PL

PL

AA

PL

AA

AA

PL

AA

PL

PL

PL

PL

PL

3,000'

AA

AA

TECC-01

PL

PL

PL

PL L PLP

PL

AA

AA

AA

AA

AA AA

AA

EXISTING EL. -24'

AA

AA

AA

P

PL

AA

AA

AA

PL AA

PL

PL PL PL

PL

AA AA

AA

2000 FT

EXISTING EL. -36'

SHIP SHOAL BORROW LAREA

PL

500 FT

AA

PL

PL

PL

TEPO-01

AA

PL

PL

PL

TEPO-02

PL

PL

PL

PL

PL

PL

PL

L PPL

AA

PPL L

PL

PL

PL

PL

EXISTING EL. -33' EXISTING EL. -34'

PL

PL

PL

PL

PL

PL

PL

PL

PL

A

PL

PL

PL

PL PL

PL

PL

PL

PL

PL

PL L P

L

L

PL PL

PL

PL

TERREBONNE BASIN BARRIER ISLAND AND BEACH NOURISHMENT

TRINITY-EAST PUMP-OUT AREAS & CONVEYANCE CORRIDORS PLAN VIEW

STATE PROJECT NUMBER: TE-143

DATE: APRIL 2018

FEDERAL PROJECT NUMBER:

SHEET 27 OF 36

PL PL

PL

PL

PL

PL

PL

FEDERAL / STATE WATER BOUNDARY

L

TECC-06 PL

PL

PL

PL AA

PL AA

AA

PL

PL

PL

AA AA

PL

500 FT

TRINITY-EAST CONVEYANCE CORRIDOR

AA AA

PL

PL

LEGEND

AA AA

ISLAND NOURISHMENT AREA LIMITS

AA

AA

PL

2000 FT

PUMP-OUT AREA LIMITS

PL

AA

AA

GULF OF MEXICO

CONVEYANCE CORRIDOR

AA

AA

AA

AA

AA

PL

PL

TECC-05

SP01

TEPO-07

AA

PL

AA

TEPO-01

PL

TEPO-08

NOTES: 1. ELEVATIONS FROM NOAA NAUTICAL CHART 11357 "TIMBALIER AND TERREBONNE BAYS", 43rd EDITION, MAY 2014, NOS SURVEYS 1990-2011 RELATIVE TO MEAN LOWER LOW WATER. 2. ALLOWABLE ANCHOR AREA EXTENDS 250 FT BEYOND THE LIMITS OF THE CONVEYANCE CORRIDORS AND PUMP-OUT AREAS. 3. SEE SHEET 36 FOR ALIGNMENT AND COORDINATE TABLES.

TECC-01 PL

2000 FT

PL

500 FT

PL

AA

AA

AA

AA

AA

AA

AA

AA

AA

AA

AA

AA AA

PL

PL

AA

SP02

SP09

AA

AA

SP01

SP10

AA

TECC-04

AA

AA

TEPO-06

PL

PL

AA

AA

TEPO-05

AA

AA

AA

AA

AA

AA AA

EXISTING EL. -31'

AA

AA

EXISTING EL. -28'

PL

AA

AA

EXISTING EL. -27'

PL

AA

AA

EXISTING EL. -22'

AA

PL

AA

EXISTING EL. -14' EXISTING EL. -21'

TRINITY-EAST PUMP-OUT AREA NO. 2

AA

PL

CONTINUED FROM SHEET 27

AA

3,000'

1,500'

0'

BY

DESCRIPTION

3,000' DATE

COASTAL ENGINEERING CONSULTANTS, INC. PH: (225) 768-1982 8570 ANSELMO LANE BATON ROUGE, LA 70810

DRAWN BY: STEVE DARTEZ

PL

PL

PL

AA

EXISTING EL. -15'

DESIGNED BY: MICHAEL T. POFF, P.E. LICENSE NUMBER: 30048

LOUISIANA COASTAL PROTECTION AND RESTORATION AUTHORITY 150 TERRACE AVENUE BATON ROUGE, LA 70802

APPROVED BY: TRAVIS BYLAND, P.E.

OCS LEASE BOUNDARY TRINITY-EAST PUMP-OUT AREA COORDINATE TRINITY-EAST CONVEYANCE CORRIDOR COORDINATE

PL

PROBABLE PIPELINE (CMD, 2010 & TE-40, 2005 )

AA

ALLOWABLE ANCHOR AREA

TERREBONNE BASIN BARRIER ISLAND AND BEACH NOURISHMENT

TRINITY-EAST PUMP-OUT AREAS & CONVEYANCE CORRIDORS PLAN VIEW

STATE PROJECT NUMBER: TE-143

DATE: APRIL 2018

FEDERAL PROJECT NUMBER:

SHEET 28 OF 36

ARTICULATED CONCRETE MAT (NOTE 2 & 5)

SEDIMENT PIPELINE

(NOTE 1)

EXISTING GRADE

(NOTE 1)

CONSTRUCTION CONTRACTOR:

OIL/GAS PIPELINE

OPTIONAL TEMPORARY ARTICULATED CONCRETE MAT PROTECTION CROSSING

PHONE NUMBER: PROJECT NAME: PERMIT NUMBER:

NOT TO SCALE

ARTICULATED CONCRETE MAT TAG

FLOTATION DEVICES (NOTE 3)

(NOTE 5)

SEA LEVEL

SEDIMENT PIPELINE

(NOTE 1)

(NOTE 1)

(NOTE 4)

EXISTING GRADE

OIL/GAS PIPELINE

OPTIONAL TEMPORARY FLOTATION CROSSING NOT TO SCALE

NOTES: 1. MEANS AND METHODS OF SEDIMENT PIPELINE CROSSING OF AN OIL/GAS PIPELINE SHALL BE COORDINATED BY THE CONSTRUCTION CONTRACTOR WITH THE OIL/GAS PIPELINE OPERATOR. 2. ARTICULATED CONCRETE MAT CONSTRUCTION AND COVERAGE AREA SHALL BE COORDINATED BY THE CONSTRUCTION CONTRACTOR WITH THE OIL/GAS PIPELINE OPERATOR 3. FLOTATION DEVICE CONSTRUCTION AND PLACEMENT SHALL BE DETERMINED BY INDUSTRY STANDARDS FOR SEDIMENT PIPELINE SUPPORT AND CONSTRUCTION CONTRACTOR STANDARD EQUIPMENT. 4. ANGLE OF SEDIMENT PIPELINE DEPARTURE FROM EXISTING GRADE SHALL BE DETERMINED BY INDUSTRY STANDARDS FOR SEDIMENT PIPELINE SUPPORT AND CONSTRUCTION CONTRACTOR EQUIPMENT. 5. INDIVIDUAL MAT SEGMENTS SHALL BE IDENTIFIED WITH THE ATTACHMENT OF A 2 INCH X 4 INCH TAG. TAGS SHALL BE MADE OF A NON-CORROSIVE MATERIAL AND ATTACHED IN A MANNER AS TO PREVENT GALVANIC CORROSION WITH THE LONGITUDINAL CABLES OF THE MATS. THE TAGS SHALL BE STAMPED OR ENGRAVED IN ACCORDANCE WITH THE ARTICULATED CONCRETE MAT TAG DETAIL ABOVE AND THE CONTRACT SPECIFICATIONS. BY

DESCRIPTION

DATE

COASTAL ENGINEERING CONSULTANTS, INC. PH: (225) 768-1982 8570 ANSELMO LANE BATON ROUGE, LA 70810

DRAWN BY: STEVE DARTEZ

DESIGNED BY: MICHAEL T. POFF, P.E. LICENSE NUMBER: 30048

LOUISIANA COASTAL PROTECTION AND RESTORATION AUTHORITY 150 TERRACE AVENUE BATON ROUGE, LA 70802

APPROVED BY: TRAVIS BYLAND, P.E.

TERREBONNE BASIN BARRIER ISLAND AND BEACH NOURISHMENT

OPTIONAL SEDIMENT PIPELINE CROSSING TYPICAL DETAILS

STATE PROJECT NUMBER: TE-143

DATE: APRIL 2018

FEDERAL PROJECT NUMBER:

SHEET 29 OF 36

3.0' SEE NOTE 1

3.0' SEE NOTE 1

FENCING POST (TYPICAL)

SAND FENCING (TYPICAL)

30'

30'

450'

NOTES: 1. THE DISTANCE BETWEEN FENCES SHALL BE INCREASED FROM 3.0' TO 8.0' AT EVERY FIFTH GAP TO ALLOW ALL-TERRAIN VEHICLE ACCESS. FENCING GAPPING DIMENSIONS NOT TO SCALE

4' WOOD SLATS 3/8"x1-1/2"

MINIMUM 13 GAUGE STEEL GALVANIZED WIRE STRANDS

50'

DUNE CREST

SAND FENCING 25

BEACH AND DUNE FILL

1

25 1 100'

FINAL GRADE

MARSH FILL

8'x4"x4" OR 8'x4"x3" DIMENSIONED POSTS UNTREATED #2 GRADE LUMBER

FENCING SECTION TYPICAL NOT TO SCALE FENCING DETAIL NOT TO SCALE

BY

DESCRIPTION

DATE

COASTAL ENGINEERING CONSULTANTS, INC. PH: (225) 768-1982 8570 ANSELMO LANE BATON ROUGE, LA 70810

DRAWN BY: STEVE DARTEZ

DESIGNED BY: MICHAEL T. POFF, P.E. LICENSE NUMBER: 30048

LOUISIANA COASTAL PROTECTION AND RESTORATION AUTHORITY 150 TERRACE AVENUE BATON ROUGE, LA 70802

APPROVED BY: TRAVIS BYLAND, P.E.

TERREBONNE BASIN BARRIER ISLAND AND BEACH NOURISHMENT

SAND FENCING DETAILS

STATE PROJECT NUMBER: TE-143

DATE: APRIL 2018

FEDERAL PROJECT NUMBER:

SHEET 30 OF 36

LEGEND BEACH/DUNE FILL PLANTING (BITTER PANICUM) MARSH FILL PLANTING (SMOOTH CORDGRASS) TIMBALIER BAY

NOTES: 1. BITTER PANICUM PLANTS SHALL BE PLANTED ON SEVEN (7) FOOT CENTERS WITH ROWS TEN (10) FEET APART. 2. SMOOTH CORDGRASS PLANTS SHALL BE PLANTED ON THREE (3) FOOT CENTERS WITH ROWS THREE (3) FEET APART. 3. SPECIES OF PLANTS ARE SUBJECT TO CHANGE DUE TO SITE CONDITIONS AND / OR CONSTRUCTION VARIABLES.

TIMBALIER ISLAND

GULF OF MEXICO

3,000'

1,500'

0'

3,000'

NORMAL GROUND

NORMAL GROUND TOP OF ROOT MEDIA TO BE PLANTED 1" BELOW NORMAL GROUND

BASE OF PLANT 2"-4" BELOW NORMAL GROUND FERTILIZER TABLET TO BE PLACED WITHIN 2"-4" OF ROOTBALL EDGE, 3" BELOW NORMAL GROUND AS SPECIFIED

BY

DESCRIPTION

SMOOTH CORDGRASS PLUG

BITTER PANICUM 4" CONTAINER DATE

COASTAL ENGINEERING CONSULTANTS, INC. PH: (225) 768-1982 8570 ANSELMO LANE BATON ROUGE, LA 70810

DRAWN BY: STEVE DARTEZ

DESIGNED BY: MICHAEL T. POFF, P.E. LICENSE NUMBER: 30048

LOUISIANA COASTAL PROTECTION AND RESTORATION AUTHORITY 150 TERRACE AVENUE BATON ROUGE, LA 70802

APPROVED BY: TRAVIS BYLAND, P.E.

TERREBONNE BASIN BARRIER ISLAND AND BEACH NOURISHMENT

TIMBALIER ISLAND VEGETATIVE PLANTING DETAILS

STATE PROJECT NUMBER: TE-143

DATE: APRIL 2018

FEDERAL PROJECT NUMBER:

SHEET 21 OF 36

LEGEND BEACH/DUNE FILL PLANTING (BITTER PANICUM) LAKE PELTO NOTES: 1. BITTER PANICUM PLANTS SHALL BE PLANTED ON SEVEN (7) FOOT CENTERS WITH ROWS TEN (10) FEET APART. 2. SPECIES OF PLANTS ARE SUBJECT TO CHANGE DUE TO SITE CONDITIONS AND / OR CONSTRUCTION VARIABLES.

TRINITY-EAST ISLAND

GULF OF MEXICO

3,000'

1,500'

3,000'

0'

NORMAL GROUND

BASE OF PLANT 2"-4" BELOW NORMAL GROUND FERTILIZER TABLET TO BE PLACED WITHIN 2"-4" OF ROOTBALL EDGE, 3" BELOW NORMAL GROUND AS SPECIFIED

BY

DESCRIPTION

DATE

COASTAL ENGINEERING CONSULTANTS, INC. PH: (225) 768-1982 8570 ANSELMO LANE BATON ROUGE, LA 70810

DRAWN BY: STEVE DARTEZ

DESIGNED BY: MICHAEL T. POFF, P.E. LICENSE NUMBER: 30048

BITTER PANICUM 4" CONTAINER

LOUISIANA COASTAL PROTECTION AND RESTORATION AUTHORITY 150 TERRACE AVENUE BATON ROUGE, LA 70802

APPROVED BY: TRAVIS BYLAND, P.E.

TERREBONNE BASIN BARRIER ISLAND AND BEACH NOURISHMENT

TRINITY-EAST ISLAND VEGETATIVE PLANTING DETAILS

STATE PROJECT NUMBER: TE-143

DATE: APRIL 2018

FEDERAL PROJECT NUMBER:

SHEET 32 OF 36

BY

DESCRIPTION

DATE

COASTAL ENGINEERING CONSULTANTS, INC. PH: (225) 768-1982 8570 ANSELMO LANE BATON ROUGE, LA 70810

DRAWN BY: STEVE DARTEZ

DESIGNED BY: MICHAEL T. POFF, P.E. LICENSE NUMBER: 30048

LOUISIANA COASTAL PROTECTION AND RESTORATION AUTHORITY 150 TERRACE AVENUE BATON ROUGE, LA 70802

APPROVED BY: TRAVIS BYLAND, P.E.

TERREBONNE BASIN BARRIER ISLAND AND BEACH NOURISHMENT STATE PROJECT NUMBER: TE-143 FEDERAL PROJECT NUMBER:

ALIGNMENT AND COORDINATE TABLES DATE: APRIL 2018 SHEET 33 OF 36

BY

DESCRIPTION

DATE

COASTAL ENGINEERING CONSULTANTS, INC. PH: (225) 768-1982 8570 ANSELMO LANE BATON ROUGE, LA 70810

DRAWN BY: STEVE DARTEZ

DESIGNED BY: MICHAEL T. POFF, P.E. LICENSE NUMBER: 30048

LOUISIANA COASTAL PROTECTION AND RESTORATION AUTHORITY 150 TERRACE AVENUE BATON ROUGE, LA 70802

APPROVED BY: TRAVIS BYLAND, P.E.

TERREBONNE BASIN BARRIER ISLAND AND BEACH NOURISHMENT STATE PROJECT NUMBER: TE-143 FEDERAL PROJECT NUMBER:

ALIGNMENT AND COORDINATE TABLES DATE: APRIL 2018 SHEET 34 OF 36

BY

DESCRIPTION

DATE

COASTAL ENGINEERING CONSULTANTS, INC. PH: (225) 768-1982 8570 ANSELMO LANE BATON ROUGE, LA 70810

DRAWN BY: STEVE DARTEZ

DESIGNED BY: MICHAEL T. POFF, P.E. LICENSE NUMBER: 30048

LOUISIANA COASTAL PROTECTION AND RESTORATION AUTHORITY 150 TERRACE AVENUE BATON ROUGE, LA 70802

APPROVED BY: TRAVIS BYLAND, P.E.

TERREBONNE BASIN BARRIER ISLAND AND BEACH NOURISHMENT STATE PROJECT NUMBER: TE-143 FEDERAL PROJECT NUMBER:

ALIGNMENT AND COORDINATE TABLES DATE: APRIL 2018 SHEET 35 OF 36

BY

DESCRIPTION

DATE

COASTAL ENGINEERING CONSULTANTS, INC. PH: (225) 768-1982 8570 ANSELMO LANE BATON ROUGE, LA 70810

DRAWN BY: STEVE DARTEZ

DESIGNED BY: MICHAEL T. POFF, P.E. LICENSE NUMBER: 30048

LOUISIANA COASTAL PROTECTION AND RESTORATION AUTHORITY 150 TERRACE AVENUE BATON ROUGE, LA 70802

APPROVED BY: TRAVIS BYLAND, P.E.

TERREBONNE BASIN BARRIER ISLAND AND BEACH NOURISHMENT STATE PROJECT NUMBER: TE-143 FEDERAL PROJECT NUMBER:

ALIGNMENT AND COORDINATE TABLES DATE: APRIL 2018 SHEET 36 OF 36

Rough impact

We use the fields in this section to decide whether to conduct an in-depth review.

Permit Manager

Dates

Identity numbers

Permits, certifications, and locations related to this particular notice

History of edits

Data are available as CSV download in the following schemas