You can copy from here when filling out the rest of the page.
RESIDENTIAL SUBDIVISION IN LIVINGSTON PARISH
NAME OF APPLICANT: NOCO, LLC, c/o Hydrik Wetlands Consultants, Attn: Michael Henry, 2323 LA Highway 190 East, Suite 2, Hammond, Louisiana 70401.
LOCATION OF WORK: Located on an approximate 32.355-acre site, in Section 25, Township 7 South, Range 3 East, along and west of Walker South Road (LA Highway 447), near Walker, Louisiana, located in Livingston Parish, as shown on the enclosed drawings (Latitude 30.40389 N Longitude -90.85689 W). This project is located in the Pontchartrain Basin (Amite River HUC 08070202).
CHARACTER OF WORK: The applicant is requesting a Department of the Army permit authorization to clear, grade, excavate, place and maintain fill material for the construction of an approximate 101-lot residential subdivision (Manor Pointe Subdivision), near Walker, Louisiana, within Livingston Parish. The proposed development would include residential homesites, 3 detention ponds, utility and drainage infrastructure and appurtenances, green space areas, and ingress/egress. Approximately 46,765 cubic yards of native material would be excavated as a result of pond construction and placed as fill in jurisdictional areas during project construction. Approximately 1.01 acres of jurisdictional forested wetlands would be directly impacted as a result of project implementation. Approximately 2.554 acres of jurisdictional forested wetlands would be avoided and not directly impacted from project implementation. Approximately 0.03 acre of jurisdictional Other Waters of the United States (OWOUS) would be filled and 0.245 acre OWOUS would be avoided and not directly impacted. The applicant has claimed that the project has been designed to avoid and minimize direct and secondary adverse wetland impacts to the maximum extent practicable. The applicant is proposing to utilize best management practices during and after the construction phase of the project. The applicant is proposing to compensate for the unavoidable impact by purchasing mitigation credits from an approved mitigation bank.
JOINT PUBLIC NOTICE
December 10, 2018
United States Army
Corps of Engineers
New Orleans District
Regulatory Branch
7400 Leake Avenue
New Orleans, Louisiana 70118
State of Louisiana
Department of Environmental Quality
Water Permits Division
Post Office Box 4313
Baton Rouge, Louisiana 70821-4313
(504) 862-1217
Project Manager
Kenny Blanke
Kenneth.G.Blanke@usace.army.mil
MVN 2018-00217-CQ
(225) 219-3225
Project Manager
Ms. Elizabeth Hill
WQC Application Number
WQC 181029-03
Interested parties are hereby notified that a permit application has been received by the
New Orleans District of the U.S. Army Corps of Engineers pursuant to: [ ] Section 10 of the
Rivers and Harbors Act of March 3, 1899 (30 Stat. 1151; 33 USC 403); and/or [X] Section 404
of the Clean Water Act (86 Stat. 816; 33 USC 1344).
Application has also been made to the Louisiana Department of Environmental Quality,
Office of Environmental Services, for a Water Quality Certification (WQC) in accordance with
statutory authority contained in LRS30:2074 A(3), and provisions of Section 401 of the Clean
Water Act (P.L.95-17).
RESIDENTIAL SUBDIVISION IN LIVINGSTON PARISH
NAME OF APPLICANT: NOCO, LLC, c/o Hydrik Wetlands Consultants, Attn: Michael Henry,
2323 LA Highway 190 East, Suite 2, Hammond, Louisiana 70401.
LOCATION OF WORK: Located on an approximate 32.355-acre site, in Section 25, Township
7 South, Range 3 East, along and west of Walker South Road (LA Highway 447), near Walker,
Louisiana, located in Livingston Parish, as shown on the enclosed drawings (Latitude 30.40389
N Longitude -90.85689 W). This project is located in the Pontchartrain Basin (Amite River HUC
08070202).
CHARACTER OF WORK: The applicant is requesting a Department of the Army permit
authorization to clear, grade, excavate, place and maintain fill material for the construction of an
approximate 101-lot residential subdivision (Manor Pointe Subdivision), near Walker, Louisiana,
within Livingston Parish. The proposed development would include residential homesites, 3
detention ponds, utility and drainage infrastructure and appurtenances, green space areas, and
ingress/egress. Approximately 46,765 cubic yards of native material would be excavated as a
result of pond construction and placed as fill in jurisdictional areas during project construction.
Approximately 1.01 acres of jurisdictional forested wetlands would be directly impacted as a
result of project implementation. Approximately 2.554 acres of jurisdictional forested wetlands
would be avoided and not directly impacted from project implementation. Approximately 0.03
acre of jurisdictional Other Waters of the United States (OWOUS) would be filled and 0.245
acre OWOUS would be avoided and not directly impacted. The applicant has claimed that the
project has been designed to avoid and minimize direct and secondary adverse wetland
impacts to the maximum extent practicable. The applicant is proposing to utilize best
management practices during and after the construction phase of the project. The applicant is
proposing to compensate for the unavoidable impact by purchasing mitigation credits from an
approved mitigation bank.
The comment period for the Department of Army Permit and the Louisiana Department
of Environmental Quality will close in 20 days from the date of this joint public notice. Written
comments, including suggestions for modifications or objections to the proposed work, stating
reasons thereof, are being solicited from anyone having interest in this permit and/or this WQC
request and must be mailed so as to be received before or by the last day of the comment
period. Letters concerning the Corps of Engineers permit application must reference the
applicant's name and the Permit Application Number, and be mailed to the Corps of Engineers
at the address above, ATTENTION: REGULATORY BRANCH. Similar letters concerning the
Water Quality Certification must reference the applicant's name and the WQC application
number and be mailed to the Louisiana Department of Environmental Quality at the address
above. Individuals or parties may request an extension of time in which to comment on the
proposed work by writing or e-mailing the Corps of Engineers Project Manager listed above.
Any request must be specific and substantively supportive of the requested extension, and
received by this office prior to the end of the initial comment period. The Section Chief will
review the request and the requestor will be promptly notified of the decision to grant or deny
the request. If granted, the time extension will be continuous to the initial comment period and,
inclusive of the initial comment period, will not exceed a total of 30 calendar days.
The application for this proposed project is on file with the Louisiana Department of
Environmental Quality and may be examined during weekdays between 8:00 a.m. and 4:30
p.m. Copies may be obtained upon payment of costs of reproduction.
Corps of Engineers Permit Criteria
The decision whether to issue a permit will be based on an evaluation of the probable
impacts, including cumulative impacts of the proposed activity on the public interest. That
decision will reflect the national concern for both protection and utilization of important
resources. The benefit which reasonably may be expected to accrue from the proposal must be
balanced against its reasonably foreseeable detriments. All factors which may be relevant to
the proposal will be considered including the cumulative effects thereof; among those are
conservation, economics, aesthetics, general environmental concerns, wetlands, historic
properties, fish and wildlife values, flood hazards, floodplain values, land use, navigation,
shoreline erosion and accretion, recreation, water supply and conservation, water quality,
energy needs, safety, food and fiber production, mineral needs, considerations of property
ownership and, in general, the needs and welfare of the people.
The US Army Corps of Engineers is soliciting comments from the public, federal, state,
and local agencies and officials, Indian Tribes, and other interested parties in order to consider
and evaluate the impacts of this proposed activity. Any comments received will be considered
by the US Army Corps of Engineers to determine whether to make, modify, condition, or deny a
permit for this proposal. To make this decision, comments are used to assess impacts on
endangered species, historic properties, water quality, general environmental effects, and other
public interest factors listed above. Comments are used in the preparation of an Environmental
Assessment and/or an Environmental Impact Statement pursuant to the National Environmental
Policy Act. Comments are also used to determine the need for a public hearing and to
determine the overall public interest of the proposed activity.
The New Orleans District is unaware of properties listed on the National Register of
Historic Places near the proposed work. The possibility exists that the proposed work may
damage or destroy presently unknown archeological, scientific, prehistorical, historical sites, or
data. Copies of this notice are being sent to the State Archeologist and State Historic
Preservation Officer.
Our initial finding is that the proposed work would neither affect any species listed as
endangered by the U.S. Departments of Interior or Commerce, nor affect any habitat
designated as critical to the survival and recovery of any endangered species. Utilizing
Standard Local Operating Procedure for Endangered Species in Louisiana (SLOPES), dated
October 22, 2014, between the U.S. Army Corps of Engineers, New Orleans and U.S. Fish and
Wildlife Service, Ecological Services Office, the Corps has determined that the proposed activity
would have no effect on any listed species.
This notice initiates the Essential Fish Habitat (EFH) consultation requirements of the
Magnuson-Stevens Fishery Conservation and Management Act. The applicant's proposal
would result in the destruction or alteration of 0 acres of EFH utilized by various life stages of
red drum and penaeid shrimp. Our initial determination is that the proposed action would not
have a substantial adverse impact on EFH or federally managed fisheries in the Gulf of Mexico.
Our final determination relative to project impacts and the need for mitigation measures is
subject to review by and coordination with the National Marine Fisheries Service.
If the proposed work involves deposits of dredged or fill material into navigable waters,
the evaluation of the probable impacts will include the application of guidelines established by
the Administrator of the Environmental Protection Agency. Also, a certification that the
proposed activity will not violate applicable water quality standards will be required from the
Department of Environmental Quality, Office of Environmental Services, before a permit is
issued.
Any person may request, in writing, within the comment period specified in this notice,
that a public hearing be held to consider this application. Requests for public hearings shall
state, with particularity, the reasons for holding a public hearing. You are requested to
communicate the information contained in this notice to any other parties whom you deem likely
to have interest in the matter.
JOHN M. HERMAN
Chief, Central Evaluation Section
Regulatory Branch
Enclosure
PLAINVIEW CHURCH CEM.
TO I-12, WALKER
Cr
DR
RY
N
HE
ee
23
R3E
JOE
ll
R4E
RD
447
MAY
lye
k
Co
k
40
43
39
24
LIVINGSTON
PARISH
DOT LEE DR
25
ARBOR
DR
DR
E 2 APRICOT
1
BF
CHRISTMAS
MANGO
0
BF
M AY
E2
RD
CK
MA
M
HA
RD
k
1
44
2
CL
UB
WWW.HYDRIK.COM
W
12
RD
y's
Gra
11
Wetlands - GIS - Flood Control
AL
30.40389 N, -90.85662 W
10
6
KE
R
SOUTH
-H
1032
T7S
T8S
HYDRIK
4
3
31
447
ee
RD
WALKER
16
Cr
u
Bayo
SOUTH
JOE
2
45
RD
er
DR
HOOD
HWY
2
Feld
k
'S
ee
PARK
WA
Y
DALLAS
VALLEY
CREEK
Cr
's
SANDYHOLLOW
DR
FIRE PROTECTION
DIST. 4, STA. NO. 4
TE
ay
SOUTH FORK
ELEM. SCHOOL
DR
RD
ell
Gr
58
30
RD
PE
DR
36
35
49
LK
AV
MACK
HAM
SITE
RIDGECREST
DR
A
PONDEROSA
DR
DR
GE
TIMBE
RR
ID
CA
TE
B U RY
N
Y
48
DR
42
W
es
t
Coly
FIG
16
W
MATT JAMES RD
EE
NC
DR LIFF
RD
DR
WN
BRO
CONIFER
DR
26
E
ou
Bay
GR
r
MA
Y
lde
RD
RD
447
JO
Fe
16
T PIT
FIRE PROTECTION
DIST. 4
STATION NO. 7
ee
Cr
W
es
t
(985)429-0333
7
1898C
9-11-2018
1
50'
50'
"
"
"
9
8
7
6
5
4
60.55'
50'
"
1
"
"
"
50'
130'
130.59'
131.09'
2
'
131.58'
132.08'
133.06'
132.57'
132.97'
50'
50'
50'
3
26
50.15'
132.97'
130.5'
10
130.5'
11
130'
28
131.48'
12
WETLANDS
0.03 FILL
LA HWY 447
R4E
SEC. 42
R/W LINE
50'
(50' R/W)
50.04'
310.0'
"
50'
"
"
'
50.19'
70 71
69
60'
N89°48'55"W 300'
WALKER SOUTH RD
50.14'
50'
R3E
SEC. 25
68
"
"
S00°59'48"W
67
"
"
"
"
"
"
66
65
50'
FILL
"
122.4'
426.34'
59.65'
50'
"
"
S00°41'26"W
50'
138.01'
"
28'
"
"
"
130'
CA-3
35.95'
3'
120
.9
50'
133.63'
111.50'
50'
50'
57.7'
50'
105'
58'
WILTON DR
58'
(50' R/W)
130'
"
"
1.62
PROPOSED
POND
0.76
W
2"
'2
0
'
°4 5.0
L
48 4
TIA
S 2
EN
5"W N
°41'2
52
S77 84.05'
1
°
16 24
9. '13
74 "
R
' W
ES
IDE
NOTE:
BASE DRAWINGS
PROVIDED BY
McLIN TAYLOR, INC.
LIVINGSTON, LA
D
SI
RE
30°24'12.44" N
-90°51'15.59" W
R/W LINE
PROPOSED
RESIDENTIAL
S00°11'05"W 340'
"
E
4'
04'5
4"W
S13°
PROJECT DATA
NT
IAL
IAL
PROJECT AREA: 32.355 ACRES
TOTAL RESIDENTIAL LOTS: 101
COMMON AREAS (3) = 12.633 AC.
POND AREAS (3) = 2.826 AC.
DENT
"W
'
PASTU
R
133
64
50'
POND
"W
170
'
S18
°56
'53
130'
"
"
"
"
"
"
.34'
367.6
'
5'
26
448.76'
"
"
BARRINGTON AVE
'
2
1.
50
WETLANDS
0.41
50.19' 50.02'
B
18
1'
°2 5'
43 .2
N 131
'
'
5
.3
3
13
12
92
63
"
RESI
50'
24.04'
"
"
130'
"
50'
A
50'
"
"
50'
50'
58.04'
62
41.66'
"
50'
'
16
13
.16'
138
72.43'
'
61
C44
30°24'15.52" N
-90°51'15.44" W
S89°14'55"E
29.71'
WETLANDS
1.90 PRESERVE
"W
716.84'
130.28'
50'
60'
FOREST
NOT-A-PART
0
12
N00°42'32"W
130.23'
60
'
'
U
YO
BA
DEVELOPMENT BOUNDARY
59
50.19'
"
0
12
FOREST
'
133.63
.04
'
67
0.
13
'
ER
RESIDENTIAL
130.17'
0
5
50
3'
°1 7'
36 .5
N 86
'
2
.4
LD
FE
22'
16'
58
8
C5
'
24'
20'
57
130.12'
'
27'
18'
72
121.28'
RESIDENTIAL
3
.3
4
10
0.
16
0
5
'
ZONE `AE'
SOUTH HAVEN
0
5
7
)
ZONE `X'
15
'
'
5
.5
7
'
18
RT
PA
OT TE
(N SI
L
L FF
FA O
T
10.837 AC
NON-WETLAND
WATERS TO REMAIN
19
7
.2
3
7
16
4
9
U
O
0.01
14
.0
0
WETLANDS
FILL
22
17
18
'
10
21
C43
WETLANDS
FILL 0.07
2
.3
7
11
'
0
5
20'
23
20
C6
C7
'
0
5
C9
"
'
12
C10
C8
6
.0
0
11
CA-1
SEC. 25
SEC. 36 S89°54'10"W
"
'
'
5
'
'
'
24
"
28'
7
.9
0
5
'
6
.1
9
12
'
0
5
0
0
5
2
1'
.3
'
'
0
25
73
'
0
5
"
10
75.04'
C1 26.56'
"
6
'
79
C11
13
77
101
C2
'
0
5
'
0
13
B
130'
2
C4
'
'
80
76
78
2
.0
0
0
DR
75
'
0
81
5
N
4
26
3
22
6
'
0
13
FILL
13
'
0
'
7
.4
0
2
5
7
27
G
TO
'
12
8
C3
7'
2.
13
N
0.11
7
.1
7
13
6
0
1
C5
82
I
RL C1 2
0
C6
28
'
.99
142
74
'
60'
100
8
C4
5
28'
'
44
56
99
C46
27'
4
1.
5
2
C5
83
HA
8'
2.1
14
134.22'
3
C1
C61
29 '
84
C37
26
C1 4
.25'
143
193'
C1 5
130.73'
0.48
0.65 PRESERVE
54
111.3'
50'
130'
"
"
POND
WETLANDS
FILL
53
35'
50'
PROPOSED
C53
NONWETLAND
WATERS (FILL)
31
"
CA-2
116.16'
55
"
'
42
2.
12
129.81'
0.20
130'
52
ZONE `X'
96 97 98
95
"
51
103.08'
7
(50' R/W)
"
1.740 AC
85
129.92'
32
"
"
45.67'
8
50'
"
"
94
93
50'
1 38
33
29'
92
"
"
"
50
"
"
"
130.03'
30
130'
105'
50'
"
50'
(50' R/W)
86
'
28
"
"
87
"
34
"
88
"
49
"
"
"
91
50'
130'
"
"
35
90
60'
"
"
36130.24'
89
"
31.01'
130.45'
37
"
9
10
RESIDENTIAL
ROSEWELL ST.
50'
38
11
"
48
"
39
112.24'
N00°37'48"E
"
119.33'
'
"
"
50'
.28
"
47
46
45
44
"
"
A
102.68'
110.81'
102.52'
29
'
225'
130.34'
606.11'
43
WATERS (FILL)
126
50'
222.12'
NON-WETLAN D42
"
"
50'
51.98'
12
930.03'
6'
114.2
40
41
'
18'
13
14
0
N00°50'03"E
111.65'
51.48'
24
45
15
16
S89°14'55"E
130.13'
EXISTING DETENTION POND
OFF SITE
17
"
18
ARBOR WALK
S
ND
TLA ILL
WE .18 F
Top Bank
19
8'
1.2
15
SEWER TREATMENT
FACILITY (OFF-SITE)
31
- 46,765 CU. YDS TO BE
EXCAVATED & DISBURSED
ON SITE
290.1'
FOREST
THIS SITE IS LOCATED IN FLOOD ZONES "AE" &"X"
PER FEMA FLOOD INSURANCE RATE MAP
NO: 220113 0250E, DATED 4/03/12; (B.F.E. = 22')
46
LEGEND:
PROJECT BOUNDARY (32.355 AC.)
TOTAL WETLANDS = 3.564 ACRES
WETLANDS TO REMAIN
PRESERVED 2.554
WETLANDS TO BE IMPACTED
VIA FILL / GRADING: 1.01 AC
NON-WETLAND WATERS
TO BE FILLED / GRADED: 418 LIN. FT / 0.03 Ac
TO REMAIN: 597 LIN. FT / 0.245 AC
ZONE
ZONE
26'
ELEVATION / LINE
100'
0'
100'
HYDRIK
FLOOD ZONE / TRANSITION LINE
DRAINAGE FLOW - PRE-DEVELOPMENT
DRAINAGE FLOW - POST DEVELOPMENT
PROPOSED DETENTION PONDS (3) 2.86 AC.
Wetlands - GIS - Flood Control
WWW.HYDRIK.COM
(985)429-0333
200'
1898 C
9-11-2018
2
SWALE
12"SLAB
SWALE
12"SLAB
LOT 85
PL
LOT 86
12"SLAB
ELEVATION - N.G.V.D
28'
27'
26'
LOT 84
SWALE
29'
PL
PL
SWALE
ELEVATION - N.G.V.D
PL
PROPOSED
GRADE
29'
28'
27'
26'
EXISTING
GRADE
AREA TO BE
FILLED
WETLANDS IMPACTED
FILLING / GRADING
SECTION A-A
PROPOSED
GRADE
SWALE
CL
PL
4" CONC
DRIVEWAY
TYP.
AVENUE
ELEVATION - N.G.V.D
4" CONC
DRIVEWAY
BARRINGTON
LOT 16
PL
29'
PL
TIE INTO
EXISTING
GRADE
CA-1
29'
12"SLAB
28'
27'
26'
WETLANDS
IMPACTED
AREA TO BE
FILLED
SEE FIGURE 4
FOR STREET DETAIL
28'
27'
26'
WETLANDS
FILLING / GRADING
ELEVATION - N.G.V.D
PROFILE VIEW - LOOKING WEST
PRESERVED
SECTION B-B
PROFILE VIEW - LOOKING NORTHEAST
LEGEND:
EXISTING GRADE
PROPOSED GRADE
WETLANDS TO BE FILLED
AREA TO BE FILLED
HYDRIK
Wetlands - GIS - Flood Control
WWW.HYDRIK.COM
PROPOSED CONCRETE
WETLANDS AREA IMPACTED
WETLANDS AREA PRESERVED
(985)429-0333
20'
10'
0'
25'
50'
1898 C
9-11-2018
3
3'-0"
12' UTILITY SERVITUDE
2'-6"
4'-0"
11'-6"
SIDEWALK
X
4'-6"
STREET LIGHT POLE
CATCH
BASIN
4'-6"
* MIN. 8% LIME SHALL BE USED IN SOIL STABILIZATION OF
SUB-BASE. FINAL DETERMINATION OF PERCENTAGE TO BE
MADE BY TESTING LAB AND APPROVED BY THE PARISH.
3" ASPHALTIC
CONCRETE
LOCATION OF SPOT
GRADES (PLAN VIEW)
2'-0" P.C. CONCRETE
MOUNTABLE CURB &
GUTTER
13'-6"
TRAVEL LANE
STORM CROSS DRAIN
BOC
SERVITUDE LINE
C
*
130'
1898 C
RESIDENCE
36" MIN.
60" MAX.
WWW.HYDRIK.COM
9-11-2018
130'
3'-0"
PL
HOME FOUNDATION
3'-0"
MIN.
C
*
12" SLAB
PROPERTY LINE
X
SIDEWALK
PROPOSED
GRADE
1'
PROPERTY LINE
15' DRAIN
SERVITUDE
CATCH BASIN
0.05 FT/FT
11'-6"
12' UTILITY SERVITUDE
SWALE
DRAINS TO
STREET
4" Conc.
DRIVEWAY
TYPICAL 50' STREET SECTION
LIME TREATMENT TO
EXTEND UNDER CURBING
LOCATION OF SPOT
GRADES (PLAN VIEW)
2'-0" P.C. CONCRETE
MOUNTABLE CURB &
GUTTER
13'-6"
TRAVEL LANE
3'-0"
MIN.
PL
SWALE
DRAINS TO
STREET
36" MIN.
60" MAX.
12" SLAB
D 4
R "
IV C
O
E N
W
C
A .
Y
SECTION C-C
SWALE
15' DRAIN
SERVITUDE
50' *
TYPICAL LOT LAYOUT
* NOTE: LOT DEMINSION VARIES
BOC
2'
TYPICAL SWALE / DITCH
Wetlands - GIS - Flood Control
HYDRIK
(985)429-0333
4