EXPANSION OF AN EXISTING TANK FACILITY IN LAFOURCHE PARISH

NAME OF APPLICANT: Loop, LLC., 137 Northpark Blvd, Covington, LA 70433.

LOCATION OF WORK: In Section 7, T19S-R22E and Section 31, T18S-R22E, within the existing LOOP facility near Galliano, Louisiana, in Lafourche Parish, within the Terrebonne Basin in hydrologic unit (HUC 08090301), as shown on the attached drawings (Latitude 29.457381 N, Longitude -90.269706 W).

CHARACTER OF WORK: The work described herein is an expansion of a facility which was previously authorized on November 10, 2010, modified on April 20, 2016. The applicant has requested Department of the Army authorization to clear, grade, excavate and deposit fill and/or aggregate material to construct and maintain a storage tank facility to include four (4) crude oil storage tanks, a valve manifold station, electrical switchgear equipment, a containment levee and access road, two (2) electrical substations with overhead distribution lines, and other associated appurtenances. Approximately 38,015 cubic yards of earthen fill will be hauled in and deposited to construct a containment berm and achieve required grade elevation requirements. Additionally, approx. 850 cubic yards of crushed limestone and 82,700 cubic yards of cement will be deposited for the construction of the project. The proposed project is situated on an approximately 40-acre tract and would permanently impact approximately 7.7 acres of emergent wetlands, 2.31 acres of forested wetlands, and approximately 1.5 acres of waters of the U.S. Additionally, approx. 0.82 acre of forested wetlands will be converted to emergent wetlands.

The applicant has designed the project to avoid and minimize direct and secondary adverse impacts to the maximum extent practicable by avoiding excavation for the project, conducting all work associated with the installation of the distribution lines from the existing roadway, and by utilizing best management practices during and after the construction phase of the project. Any further reduction would limit usage of the property and therefore function, deeming the project impracticable. Compensatory mitigation has been previously assessed and collected at this project site for the direct impacts to wetlands caused through implementation of the hurricane protection levee and the associated secondary development of wetlands within the system. No additional compensatory mitigation will be required.

JOINT PUBLIC NOTICE January 14, 2019 United States Army Corps of Engineers New Orleans District Regulatory Branch 7400 Leake Avenue New Orleans, Louisiana 70118

State of Louisiana Department of Environmental Quality Office of Environmental Services Post Office Box 4313 Baton Rouge, Louisiana 70821-4313

(504) 862-1545 Project Manager S. Gail Gainey Sandra.G.Gainey@usace.army.mil MVN 2010-02021-CG

(225) 219-3225 Project Manager Elizabeth Hill WQC Application Number WQC # 170330-02

Interested parties are hereby notified that a permit application has been received by the New Orleans District of the US Army Corps of Engineers pursuant to: [ ] Section 10 of the Rivers and Harbors Act of March 3, 1899 (30 Stat. 1151; 33 USC 403); and/or [X] Section 404 of the Clean Water Act (86 Stat. 816; 33 USC 1344). Application has also been made to the Louisiana Department of Environmental Quality, Office of Environmental Services, for a Water Quality Certification (WQC) in accordance with statutory authority contained in LRS 30:2074 A(3) and provisions of Section 401 of the Clean Water Act. EXPANSION OF AN EXISTING TANK FACILITY IN LAFOURCHE PARISH NAME OF APPLICANT: Loop, LLC., 137 Northpark Blvd, Covington, LA 70433. LOCATION OF WORK: In Section 7, T19S-R22E and Section 31, T18S-R22E, within the existing LOOP facility near Galliano, Louisiana, in Lafourche Parish, within the Terrebonne Basin in hydrologic unit (HUC 08090301), as shown on the attached drawings (Latitude 29.457381 N, Longitude -90.269706 W). CHARACTER OF WORK: The work described herein is an expansion of a facility which was previously authorized on November 10, 2010, modified on April 20, 2016. The applicant has requested Department of the Army authorization to clear, grade, excavate and deposit fill and/or aggregate material to construct and maintain a storage tank facility to include four (4) crude oil storage tanks, a valve manifold station, electrical switchgear equipment, a containment levee and access road, two (2) electrical substations with overhead distribution lines, and other associated appurtenances. Approximately 38,015 cubic yards of earthen fill will be hauled in and deposited to construct a containment berm and achieve required grade elevation requirements. Additionally, approx. 850 cubic yards of crushed limestone and 82,700 cubic yards of cement will be deposited for the construction of the project. The proposed project is situated on an approximately 40-acre tract and would permanently impact approximately 7.7 acres of emergent wetlands, 2.31

2 acres of forested wetlands, and approximately 1.5 acres of waters of the U.S. Additionally, approx. 0.82 acre of forested wetlands will be converted to emergent wetlands. The applicant has designed the project to avoid and minimize direct and secondary adverse impacts to the maximum extent practicable by avoiding excavation for the project, conducting all work associated with the installation of the distribution lines from the existing roadway, and by utilizing best management practices during and after the construction phase of the project. Any further reduction would limit usage of the property and therefore function, deeming the project impracticable. Compensatory mitigation has been previously assessed and collected at this project site for the direct impacts to wetlands caused through implementation of the hurricane protection levee and the associated secondary development of wetlands within the system. No additional compensatory mitigation will be required. The comment period for the Department of Army will close in 20 days from the date of this joint public notice. Written comments, including suggestions for modifications or objections to the proposed work, stating reasons thereof, are being solicited from anyone having interest in this permit and/or this WQC request and must be mailed so as to be received before or by the last day of the comment period. Letters concerning the Corps of Engineers permit application must reference the applicant's name and the Permit Application Number, and be mailed to the Corps of Engineers at the address above, ATTENTION: REGULATORY BRANCH. Similar letters concerning the Water Quality Certification must reference the applicant's name and the WQC application number and be mailed to the Louisiana Department of Environmental Quality at the address above. Individuals or parties may request an extension of time in which to comment on the proposed work by writing or e-mailing the Corps of Engineers Project Manager listed above. Any request must be specific and substantively supportive of the requested extension, and received by this office prior to the end of the initial comment period. The Section Chief will review the request and the requestor will be promptly notified of the decision to grant or deny the request. If granted, the time extension will be continuous to the initial comment period and, inclusive of the initial comment period, will not exceed a total of 30 calendar days. The application for this proposed project is on file with the Louisiana Department of Environmental Quality and may be examined during weekdays between 8:00 a.m. and 4:30 p.m. Copies may be obtained upon payment of costs of reproduction. Corps of Engineers Permit Criteria The decision whether to issue a permit will be based on an evaluation of the probable impacts, including cumulative impacts of the proposed activity on the public interest. That decision will reflect the national concern for both protection and utilization of important resources. The benefit which reasonably may be expected to accrue from the proposal must be balanced against its reasonably foreseeable detriments. All factors which may be relevant to the proposal will be considered including the cumulative effects thereof; among those are conservation, economics, aesthetics, general environmental concerns, wetlands, historic properties, fish and wildlife values, flood hazards, floodplain values, land use, navigation, shoreline erosion and accretion, recreation, water supply and

3 conservation, water quality, energy needs, safety, food and fiber production, mineral needs, considerations of property ownership and, in general, the needs and welfare of the people. The US Army Corps of Engineers is soliciting comments from the public, federal, state, and local agencies and officials, Indian Tribes, and other interested parties in order to consider and evaluate the impacts of this proposed activity. Any comments received will be considered by the US Army Corps of Engineers to determine whether to make, modify, condition, or deny a permit for this proposal. To make this decision, comments are used to assess impacts on endangered species, historic properties, water quality, general environmental effects, and other public interest factors listed above. Comments are used in the preparation of an Environmental Assessment and/or an Environmental Impact Statement pursuant to the National Environmental Policy Act. Comments are also used to determine the need for a public hearing and to determine the overall public interest of the proposed activity. The New Orleans District is unaware of properties listed on the National Register of Historic Places near the proposed work. The possibility exists that the proposed work may damage or destroy presently unknown archeological, scientific, prehistorical, historical sites, or data. Copies of this notice are being sent to the State Archeologist and the State Historic Preservation Officer. Our initial finding is that the proposed work would neither affect any species listed as endangered by the U.S. Departments of Interior or Commerce, nor affect any habitat designated as critical to the survival and recovery of any endangered species. Utilizing Standard Local Operating Procedure for Endangered Species in Louisiana (SLOPES), dated October 22, 2014, between the U.S. Army Corps of Engineers, New Orleans and U.S. Fish and Wildlife Service, Ecological Services Office, the Corps has determined that the proposed activity would have no effect on any listed species. This notice initiates the Essential Fish Habitat (EFH) consultation requirements of the Magnuson-Stevens Fishery Conservation and Management Act. The applicant's proposal would result in the destruction or alteration of up to n/a acres of EFH utilized by various life stages of red drum and penaeid shrimp. Our initial determination is that the proposed action would not have a substantial adverse impact on EFH or federally managed fisheries in the Gulf of Mexico. Our final determination relative to project impacts and the need for mitigation measures is subject to review by and coordination with the National Marine Fisheries Service. If the proposed work involves deposits of dredged or fill material into navigable waters, the evaluation of the probable impacts will include the application of guidelines established by the Administrator of the Environmental Protection Agency. Also, a certification that the proposed activity will not violate water quality standards will be required from the Department of Environmental Quality, Office of Environmental Services before a permit is issued. Any person may request, in writing, within the comment period specified in this notice, that a public hearing be held to consider this application. Requests for public hearings shall state, with particularity, the reasons for holding a public hearing. You are requested

4 to communicate the information contained in this notice to any other parties whom you deem likely to have interest in the matter. The applicant has certified that the proposed activity described in the application complies with and will be conducted in a manner that is consistent with the Louisiana Coastal Resources Program (Louisiana Coastal Zone Applications C20170019 and C20180094). The Department of the Army permit will not be issued unless the applicant received approval or a waiver of the Coastal Use Permit by the Department of Natural Resources.

JOHN M. HERMAN Chief, Central Evaluation Section Regulatory Branch Enclosures

LOOP LLC Covington, Louisiana

Tank Facility Expansion

Site Location

s

0

2

Miles Reference: Basemap ESRI USA Topo Maps, Available on ArcGIS Online

CK

ASSOCIAT1~~

Ef1Ylronmentcl Coosu

~ -~~ Figure 1

LOOP LLC

Legend

Covington, Louisiana

....-...... L_.._J Proposed Expansion (33.1 acres) ~ Herbaceous Wetlands (7.7 acres)

~ Other Waters of the US (1.5 acres)

Tank Facility Expa nsion

s

Existing Cond itions Lafourche Parish BLN/AM l 0.4

TEW

TEW 12/29/2016

Dwg. No.:

A14431-02

Feet Reference: Basemap ESRI Wor ld imagery, Available on ArcGIS Online

Figure 2

See Figure 6 for Typical Drainage Canal Cross-Sect ion See Figure 7 for Typical Drainage Swale Cross-Section See Figure 4 for Typical Dike Cross-Section

See Figure 5 for Typical Tank Details

T-6426

MANI FOLD AREA

N

Legend

..-·-··L .._J

Proposed Expansion (33.1 acres)

~ Herbaceous Wetlands to be Filled (7.7 acres)

~ s

8888l Other Waters of the US to be Filled (1.5 acres)

LOOP LLC Covingt on, Louisiana

Tank Facility Expansion

Plan View Lafourche Parish BLN AMl0.4 TEW

0

100

200

300

Feet Reference: Base map ESRI World imagery, Available on ArcGI S Online

0. esn

TEW

12/29/2016

Figure 3

PRIMARY CONTAINMENT LEVEE & ACCESS ROAD

6" CRUSHE D LIMESTO NE COMPACTED FILL

OUTER PERIMETER CONTAINM ENT LEVEE TOTAL LENGTH = 3 ,050 FT. TOTAL VOLUME = 19,070 CU. YDS. TOTAL VOLUM E IN HERBACEOUS W ETLANDS = 294 CU. YDS. TOTAL VOLUME IN OTHER WATERS= 33 CU. YDS.

LOOP LLC Covington, Loui siana

Tank Facility Expansion

Typical Dike Cross-Section Lafourche Parish Drawn: Checked: Appr oved: Date: Dwg. No.:

CAL/ACAD BLN TEW

12/22/ 16

A14431-04

FIGURE 4

WINDGIRDER

- - -

- - - - - -- -

----------- - -- - ----

90

SHELL

11'1

ANNULAR RING

BOTTOM

IE

IE 310' TYPICAL TANK ELEVATION

310' TANK SHELL SAND & SOIL CEMENT FI LL

:t ··j;·

ID

:t

:t

:t

::t

·-j;·

·-j;·

j;·

·j;

·· j;

·· j;·

·· j;·

.

..

..

..

.. .·

..

l

··j;·

J

J·

:t

..

:t

:t

··j;·

·"j;

"j;

. .

.

.

.

:·". , ..

:.-,:.

·"j;·

··f;·

l\'. l+~ 'l+~ l'.!'...· l'.r·.. l'.f:... '::;:.l".. l'.f:, k l.,. l l.,.. l l::,:.. . .

0

:t

J

~r. .;r;·

.

~r. "

'!:"

J

"· ·:f··

..

,

,

,

,

, ..

~r.

J.:,

~r. .;r.·

/(

~r.

~f.

·: .

( ,

" ·t

'L

,-:, ..

:.-,:. , ..

~r

·..

.j..

~r.

,-:r(,..

.

, ..

J

,-:r.· ( ,

.

:.-· . , ..

l

" ·;r;·

.

.

:.-· .

r, ..

~r.

" ·;r;·

, ..

~r.

" ·;f;·

8'0 SOIL- CEMENT MIX COLUMNS

TYPICAL TANK FOUNDATION

LOOP, LLC Covington, Louisiana TOTA L SAND & SOIL CEM ENT FILL IN HERBACEOUS WETLANDS = 28,663 CU. YDS. TOTAL SAND & SOIL CEMENT FILL IN OTHER WATE RS = 1,522 CU. YDS. TOTAL SOIL/CEMENT COLUMNS IN HERBACEOUS WETLANDS = 49,946 CU. YDS. TOTAL SOIL/CEM ENT COLUMNS IN OTHER WATERS = 2,629 CU. YDS.

Ta nk Facility Expansion

Typical Tank Details Lafourche Parish Drawn: Checked: Approved: Date:

Dwg. No.:

CAL/ACAD BLN TEW

12/ 22/ 16

A1443 1-05

FIG URE 5

± 20'

EXISTING DRAINAGE DITCH

FI LL DRAINAGE CANAL INSIDE THE TANKS CONTAINMENT LEVEE TOTAL LENGTH = 670 FT. TOTAL FILL VOLUME IN OTHER WATERS = 2,960 CU. YDS .

LOOP, LLC Covington, Louisiana

Tank Facility Expa nsion

Typical Drainage Canal Cross-Section Lafourche Parish Drawn:

CAL/A CAD

Checked: Approved: Date:

BLN TEW

Dw g. No.:

A14431-06

12/22/16

FIGURE 6

± 10' EXISTING DRAINAGE SWALE

FILL DRAINAGE SWALE INSIDE THE TANKS CONTAINMENT LEVEE TOTAL LENGTH = 2,235 FT. TOTAL FILL VO LU ME IN OTHER WATERS = 1,439 CU. YDS.

LOOP, LLC Covingt o n, Louisiana

Tan k Facil it y Expansion

Typical Drainage Swale Cross-Section Lafourche Parish Drawn: Checked : Approved : Date: Dwg. No.:

CAL/ACAD BLN TEW

12/30/16

A14431-07

FIGURE 7

Rough impact

We use the fields in this section to decide whether to conduct an in-depth review.

Permit Manager

Dates

Identity numbers

Permits, certifications, and locations related to this particular notice

History of edits

Data are available as CSV download in the following schemas