Home

New Orleans District

Run scraper

Union Pacific Railway Corporation

Basic information

Fill out these two fields at minimum.

— or —

How Big?

Where?

Links to source documents

Raw text

You can copy from here when filling out the rest of the page.

RAIL STORAGE YARD EXPANSION IN CALCASIEU PARISH

Name of applicant: Union Pacific Railway Corporation, c/o CH2M Hill, Attn: Blake Amos, 2112 Eleventh Avenue South, Suite 320, Birmingham, Alabama 35205

Location of work: 30.23828oN, 93.30865oW, in Westlake, Louisiana, in CALCASIEU Parish, as shown on the enclosed drawings.

Character of work: Place approximately 7,685 cubic yards of earthen material, 13,846 cubic yards of subballast, 22,315 cubic yards of ballast, and 12 cubic yards of rip-rap, all to facilitate construction of a rail storage yard expansion. Approximately 10.75 acres of unavoidable wetland impacts will be compensated for through the purchase of credits from an approved mitigation bank in the same hydrologic basin (HUC 08080206).

JOINT PUBLIC NOTICE March 24, 2014 United States Army Corps of Engineers New Orleans District Regulatory Branch Post Office Box 60267 New Orleans, LA 70160-0267

State of Louisiana Department of Environmental Quality Office of Environmental Services Post Office Box 4313 Baton Rouge, LA 70821-4313

(504) 862-1879 Project Manager Ms. Angelle Greer Permit Application Number MVN-2014-00147-WMM

(225) 219-3225 Project Manager Elizabeth Johnson WQC Application Number WQC 140321-01

Interested parties are hereby notified that a permit application has been received by the New Orleans District of the U.S. Army Corps of Engineers pursuant to: [ ] Section 10 of the Rivers and Harbors Act of March 3, 1899 (30 Stat. 1151; 33 USC 403); and/or [X] Section 404 of the Clean Water Act (86 Stat. 816; 33 USC 1344). Application has also been made to the Louisiana Department of Environmental Quality for a Water Quality Certification (WQC) in accordance with statutory authority contained in LRS 30:2074 A(3) and provisions of Section 401 of the Clean Water Act." RAIL STORAGE YARD EXPANSION IN CALCASIEU PARISH Name of applicant: Union Pacific Railway Corporation, c/o CH2M Hill, Attn: Blake Amos, 2112 Eleventh Avenue South, Suite 320, Birmingham, Alabama 35205 Location of work: 30.23828oN, 93.30865oW, in Westlake, Louisiana, in CALCASIEU Parish, as shown on the enclosed drawings. Character of work: Place approximately 7,685 cubic yards of earthen material, 13,846 cubic yards of subballast, 22,315 cubic yards of ballast, and 12 cubic yards of rip-rap, all to facilitate construction of a rail storage yard expansion. Approximately 10.75 acres of unavoidable wetland impacts will be compensated for through the purchase of credits from an approved mitigation bank in the same hydrologic basin (HUC 08080206). The comment period for the Department of the Army Permit and the Louisiana Department of Environmental Quality WQC will close 20 days from the date of this joint public notice. Written comments, including suggestions for modifications or objections to the proposed work, stating reasons thereof, are being solicited from anyone having interest in this permit and/or this WQC request and must be mailed so as to be received before or by the last day of the comment period. Letters concerning the Corps of Engineers permit application must reference the applicant's name and the Permit Application Number, and be mailed to the Corps of Engineers at the address above, ATTENTION: REGULATORY BRANCH. Individuals or parties may request an extension of time in which to comment on the proposed work by writing to the project manager or clicking on the project manager's name on the public notice grid on the web page. Any request must be specific and substantively supportive of the requested extension and received by this office prior to the end of the initial comment period. The Section Chief will review the request and the requestor will be promptly notified of the decision to grant or deny the request. If granted, the time extension will be continuous to the initial comment period and, inclusive of the initial comment period, will not exceed a total of 30 calendar days. Letters concerning the Water Quality Certification must reference the applicant's name and the WQC Application number and be mailed to the Louisiana Department of Environmental Quality at the address above. The application for this proposed project is on file with the Louisiana Department of Environmental Quality and may be examined weekdays between 8:00 a.m. and 4:30 p.m. Copies may be obtained upon payment of costs of reproduction. Corps of Engineers Permit Criteria The decision whether to issue a permit will be based on an evaluation of the probable impacts, including cumulative impacts of the proposed activity on the public interest. That decision will reflect the national concern for both protection and utilization of important resources. The benefit which reasonably may be expected to accrue from the proposal must be balanced against its reasonably foreseeable detriments. All factors which may be relevant to the proposal will be considered including the cumulative effects thereof; among those are conservation, economics, aesthetics, general environmental concerns, wetlands, historic properties, fish and wildlife values, flood hazards, floodplain values, land use, navigation, shoreline erosion and accretion, recreation, water supply and conservation, water quality, energy needs, safety, food and fiber production, mineral needs, considerations of property ownership and, in general, the needs and welfare of the people. The U.S. Army Corps of Engineers is soliciting comments from the public, Federal, state, and local agencies and officials, Indian Tribes, and other interested parties in order to consider and evaluate the impacts of this proposed activity. Any comments received will be considered by the U.S. Army Corps of Engineers to determine whether to make, modify, condition, or deny a permit for this proposal. To make this decision, comments are used to assess impacts on endangered species, historic properties, water quality, general environmental effects, and other public interest factors listed above.

Comments are used in the preparation of an Environmental Assessment and/or an Environmental Impact Statement pursuant to the National Environmental Policy Act. Comments are also used to determine the need for a public hearing and to determine the overall public interest of the proposed activity. No properties listed on the National Register of Historic Places are near the proposed work. The possibility exists that the proposed work may damage or destroy presently unknown archeological, scientific, prehistorical, historical sites, or data. Copies of this notice are being sent to the State Archeologist and the State Historic Preservation Officer. Our initial finding is that the proposed work would neither affect any species listed as endangered by the U.S. Departments of Interior or Commerce, nor affect any habitat designated as critical to the survival and recovery of any endangered species. This notice initiates the Essential Fish Habitat (EFH) consultation requirements of the Magnuson-Stevens Fishery Conservation and Management Act. The applicant's proposal would result in the destruction or alteration of 0.0 acre(s) of EFH utilized by various life stages of red drum and penaeid shrimp. Our initial determination is that the proposed action would not have a substantial adverse impact on EFH or federally managed fisheries in the Gulf of Mexico. Our final determination relative to project impacts and the need for mitigation measures is subject to review by and coordination with the National Marine Fisheries Service. If the proposed work involves deposits of dredged or fill material into navigable waters, the evaluation of the probable impacts will include the application of guidelines established by the Administrator of the Environmental Protection Agency. Also, a certification that the proposed activity will not violate applicable water quality standards will be required from the Department of Environmental Quality, Office of Environmental Services before a permit is issued. Any person may request, in writing, within the comment period specified in this notice, that a public hearing be held to consider this application. Requests for public hearings shall state, with particularity, the reasons for holding a public hearing. You are requested to communicate the information contained in this notice to any other parties whom you deem likely to have interest in the matter.

Darrell S. Barbara Chief, Western Evaluation Section Enclosures

POB Latitude: 30°14'17.804" N Longitude: 93°18'31.128" W

Path: R:\GIS\HOU\UPRR\Lockmoor\MapFiles\Permit\Lockmoor_Vicinity_Map.mxd - 2/11/2014 @ 9:37:47 AM

POE Latitude: 30°14'17.391" N Longitude: 93°16'59.729" W

Copyright:© 2013 National Geographic Society, i-cubed February 11, 2014

Rail Centerline

Arkansas

Major Highway

Mississippi

Interstate Project Boundary 0

¯

Texas Louisiana

10,000

Feet

1 in = 10,000 ft

Vicinity Map UPRR Lockmoor Yard Expansion, Lafayette Subdivision MP 224.35 to MP 222.98

Figure 1

Sheet 1 of 13

POE Latitude: 30°14'17.391" N Longitude: 93°16'59.729" W

Path: R:\GIS\HOU\UPRR\Lockmoor\MapFiles\Permit\Lockmoor_Existing_Conditions.mxd - 2/11/2014 @ 10:09:06 AM

POB Latitude: 30°14'17.804" N Longitude: 93°18'31.128" W

February 11, 2014

Rail Centerline Road Centerline

?

Surface Water and Flow Direction Project Boundary 0

¯ Feet

1 in = 3,000 ft

Existing Conditions UPRR Lockmoor Yard Expansion, Lafayette Subdivision MP 224.35 to MP 222.98

3,000

© OpenStreetMap (and) contributors, CC-BY-SA

Figure 1

Sheet 2 of 13

S007 Permanent Impact: 0.03 ac Temporary Impact: 0.006 ac (187 cy) To be filled by proposed track and access road construction

Calcasieu Parish W16 Permanent Impact: 0.05 ac Temporary Impact: 0.004 ac (322 cy) To be filled by proposed track, access road, and culvert construction

W15 Permanent Impact: 0.68 ac Temporary Impact: 0.03 ac (3,911 cy) To be filled by proposed track, access road, and culvert construction

W17 Permanent Impact: 0.70 ac Temporary Impact: 0.04 ac (4,073 cy) To be filled by proposed track and access road construction

Pond 1 Permanent Impact: 0.30 ac Temporary Impact: 0.001 ac (1,653 cy) To be filled by proposed track and access road construction ???????? ???????? ?????

?

?

?

?

?

?

?

???????? ????????

???????? ???????? ???????? ??? ????? ????

Prater Road

Proposed Culvert (See Sheet 12)

?

?????? ?

?

?

?

?

?

?

?

?

?

POB Latitude: 30°14'17.804" N Longitude: 93°18'31.128" W

Wetland/WOUS Fill Substrates and Quantities Substrate

5626

1,416

Ba l l a s t Fi l l

17946

2,316

Ri p Ra p Fi l l Total:

10876 0

34,448

Napoleon St.

WOUS Fill Quantity (CY)

Ea rthen Fi l l

Subba l l a s t Fi l l

R:\GIS\HOU\UPRR\Lockmoor\MapFiles\Permit\Lockmoor_Permit_DataDriven.mxd - 2/11/2014 @ 10:16:03 AM

Wetland Fill Quantity (CY)

90 ¥

12

5,470

Wetland/WOUS

Permanent Impact Acreage Temporary Impact Acreage

Pa l us tri ne Needl e-Lea ved Deci duous Fores ted (PFO2)

4.86

0.18

Pers i s tent Pa l us tri ne Emergent (PEM1)

0.23

0.06

Pa l us tri ne Broa d-Lea ved Deci duous Fores ted (PFO1)

0.14

Pa l us tri ne Broa d-Lea ved Deci duous Shrub-Scrub (PSS1) 0.71 Dra i na ge Di tch/Ephemera l Strea m

0.67

Total:

6.91

Ma nma de Pond

Grading Limits

Existing Bridge

Road Centerline

Existing Culvert

Existing Access Road Proposed Track

Proposed Culvert ????

0.30

Existing Right of Way Existing Track

Proposed Surface Flow Road Improvement

W14 Permanent Impact: 0.90 ac Temporary Impact: 0.03 ac (5,174 cy) To be filled by proposed track and access road construction W18 Temporary Impact: 0.02 ac (87 cy) To be filled by culvert construction

1,726

Permanent and Temporary Wetland/WOUS Impacts

S005 Permanent Impact: 0.47 ac Temporary Impact: 0.001 ac. (2,598 cy) To be filled by proposed track and access road construction

0.02 0.11

W19 Temporary Impact: 0.01 ac (50 cy) To be filled by culvert construction

0.03

0.001 0.40

February 11, 2014

Signal Case

Potential Jurisdictional Waters of the U.S. Potential Jurisdictional Wetlands Pond

Permanent Workspace Temporary Workspace

0

¯ Feet 1 in = 200 ft

Plan View UPRR Lockmoor Yard Expansion, Lafayette Subdivision MP 224.35 to MP 222.98

3

200

4

5

6

7

8

© OpenStreetMap (and) contributors, CC-BY-SA

Figure 1 Sheet 3 of 13

9

Calcasieu Parish

W11 Permanent Impact: 1.54 ac Temporary Impact: 0.03 ac (8,496 cy) To be filled by proposed track and access road construction

W14 Permanent Impact: 0.90 ac Temporary Impact: 0.03 ac (5,174 cy) To be filled by proposed track and access road construction

0.68 ac .03 ac d by ess road, tion

W12 Permanent Impact: 0.64 ac Temporary Impact: 0.01 ac (3,531 cy) To be filled by proposed track and access road construction W13 Permanent Impact: 0.25 ac Temporary Impact: 0.01 ac (1,447 cy) To be filled by proposed track and access road construction

act: 0.30 ac ct: 0.001 ac filled by and access n

???????? ???????? ???????? ???????? ???????? ? ??????? ???????? ???????? ???????? ???????? ??????? ? ???????? ??????

S005 Permanent Impact: 0.47 ac Temporary Impact: 0.001 ac (2,598 cy) To be filled by proposed track and access road construction

c c

s

Wetland/WOUS Fill Substrates and Quantities Substrate

5626

1,416

Ba l l a s t Fi l l

17946

2,316

Ri p Ra p Fi l l Total:

10876 0

34,448

1,726 12

5,470

Permanent and Temporary Wetland/WOUS Impacts Wetland/WOUS

Permanent Impact Acreage Temporary Impact Acreage

Pa l us tri ne Needl e-Lea ved Deci duous Fores ted (PFO2)

4.86

0.18

Pers i s tent Pa l us tri ne Emergent (PEM1)

0.23

0.06

Pa l us tri ne Broa d-Lea ved Deci duous Fores ted (PFO1)

0.14

Pa l us tri ne Broa d-Lea ved Deci duous Shrub-Scrub (PSS1) 0.71 Dra i na ge Di tch/Ephemera l Strea m

0.67

Total:

6.91

Ma nma de Pond

Grading Limits

Existing Bridge

Road Centerline

Existing Culvert

Existing Access Road Proposed Track

Proposed Culvert ????

0.30

Existing Right of Way Existing Track

Proposed Surface Flow Road Improvement

90 ¥

WOUS Fill Quantity (CY)

Ea rthen Fi l l

Subba l l a s t Fi l l

R:\GIS\HOU\UPRR\Lockmoor\MapFiles\Permit\Lockmoor_Permit_DataDriven.mxd - 2/11/2014 @ 10:16:05 AM

Wetland Fill Quantity (CY)

Napoleon St.

0.02 0.11 0.03

0.001 0.40

February 11, 2014

Signal Case

Potential Jurisdictional Waters of the U.S. Potential Jurisdictional Wetlands Pond

Permanent Workspace Temporary Workspace

0

¯ Feet 1 in = 200 ft

Plan View UPRR Lockmoor Yard Expansion, Lafayette Subdivision MP 224.35 to MP 222.98

3

200

4

5

6

7

8

© OpenStreetMap (and) contributors, CC-BY-SA

Figure 1 Sheet 4 of 13

9

Calcasieu Parish

W11 Permanent Impact: 1.54 ac Temporary Impact: 0.03 ac (8,496 cy) To be filled by proposed track and access road construction W10 Permanent Impact: 0.06 ac Temporary Impact: 0.01 ac (341 cy) To be filled by proposed track and access road construction W20 Permanent Impact: 0.04 ac (221 cy) To be filled by proposed track and access road construction

???????? ???????? ???????? ???????? ???????? ????? ??? ???????? ????? ??? ? ???? ??? ???? ??? ? ? ?? ??? ?? ?? ?? ??? ? ? ?? ?? ??

S005 Permanent Impact: 0.47 ac Temporary Impact: 0.001 ac (2,598 cy) To be filled by proposed track and access road construction

.47 ac .001 ac d by access

Wetland/WOUS Fill Substrates and Quantities Substrate

WOUS Fill Quantity (CY)

5626

1,416

Ba l l a s t Fi l l

17946

2,316

Ri p Ra p Fi l l Total:

10876 0

34,448

Napoleon St.

90 ¥

Ea rthen Fi l l

Subba l l a s t Fi l l

R:\GIS\HOU\UPRR\Lockmoor\MapFiles\Permit\Lockmoor_Permit_DataDriven.mxd - 2/11/2014 @ 10:16:08 AM

Wetland Fill Quantity (CY)

1,726 12

5,470

Permanent and Temporary Wetland/WOUS Impacts Wetland/WOUS

Permanent Impact Acreage Temporary Impact Acreage

Pa l us tri ne Needl e-Lea ved Deci duous Fores ted (PFO2)

4.86

0.18

Pers i s tent Pa l us tri ne Emergent (PEM1)

0.23

0.06

Pa l us tri ne Broa d-Lea ved Deci duous Fores ted (PFO1)

0.14

Pa l us tri ne Broa d-Lea ved Deci duous Shrub-Scrub (PSS1) 0.71 Dra i na ge Di tch/Ephemera l Strea m

0.67

Total:

6.91

Ma nma de Pond

Grading Limits

Existing Bridge

Road Centerline

Existing Culvert

Existing Access Road Proposed Track

Proposed Culvert ????

0.30

Existing Right of Way Existing Track

Proposed Surface Flow Road Improvement

S006 Permanent Impact: 0.02 ac Temporary Impact: 0.001 ac (92 cy) To be filled by proposed track and access road construction

0.02 0.11 0.03

0.001 0.40

February 11, 2014

Signal Case

Potential Jurisdictional Waters of the U.S. Potential Jurisdictional Wetlands Pond

Permanent Workspace Temporary Workspace

0

¯ Feet 1 in = 200 ft

Plan View UPRR Lockmoor Yard Expansion, Lafayette Subdivision MP 224.35 to MP 222.98

3

200

4

5

6

7

8

© OpenStreetMap (and) contributors, CC-BY-SA

Figure 1 Sheet 5 of 13

9

Calcasieu Parish

W9 Permanent Impact: 0.05 ac Temporary Impact: 0.01 ac (323 cy) To be filled by proposed track and access road construction W6 Temporary Impact: 0.0002 ac (1 cy) To be filled by slope embankment construction W8 Permanent Impact: 0.01 ac Temporary Impact: 0.01 ac (110 cy) To be filled by proposed track and access road construction

W7 No Impacts

??? ?? ??? ??? ?? ?? ? ? ??????? ???????? ???????? ???????? ?????? ?

S005 Permanent Impact: 0.47 ac Temporary Impact: 0.001 ac (2,598 cy) To be filled by proposed track and access road construction

t: 0.02 ac t: 0.001 ac d by nd access

Napoleon St. Wetland/WOUS Fill Substrates and Quantities Substrate

WOUS Fill Quantity (CY)

Ea rthen Fi l l

5626

1,416

Ba l l a s t Fi l l

17946

2,316

Subba l l a s t Fi l l

R:\GIS\HOU\UPRR\Lockmoor\MapFiles\Permit\Lockmoor_Permit_DataDriven.mxd - 2/11/2014 @ 10:16:10 AM

Wetland Fill Quantity (CY)

Ri p Ra p Fi l l Total:

10876 0

34,448

1,726 12

5,470

Permanent and Temporary Wetland/WOUS Impacts Wetland/WOUS

Permanent Impact Acreage Temporary Impact Acreage

Pa l us tri ne Needl e-Lea ved Deci duous Fores ted (PFO2)

4.86

0.18

Pers i s tent Pa l us tri ne Emergent (PEM1)

0.23

0.06

Pa l us tri ne Broa d-Lea ved Deci duous Fores ted (PFO1)

0.14

Pa l us tri ne Broa d-Lea ved Deci duous Shrub-Scrub (PSS1) 0.71 Dra i na ge Di tch/Ephemera l Strea m

0.67

Total:

6.91

Ma nma de Pond

Grading Limits

Existing Bridge

Road Centerline

Existing Culvert

Existing Access Road Proposed Track

Proposed Culvert ????

0.30

Existing Right of Way Existing Track

Proposed Surface Flow Road Improvement

90 ¥

0.02 0.11 0.03

0.001 0.40

February 11, 2014

Signal Case

Potential Jurisdictional Waters of the U.S. Potential Jurisdictional Wetlands Pond

Permanent Workspace Temporary Workspace

0

¯ Feet 1 in = 200 ft

Plan View UPRR Lockmoor Yard Expansion, Lafayette Subdivision MP 224.35 to MP 222.98

3

200

4

5

6

7

8

© OpenStreetMap (and) contributors, CC-BY-SA

Figure 1 Sheet 6 of 13

9

Calcasieu Parish

W6 Temporary Impact: 0.0002 ac (1 cy) To be filled by slope embankment construction S003 Permanent Impact: 0.01 ac Temporary Impact: 0.004 ac (63 cy) To be filled by access road construction

S004 No Impacts

W5 Permanent Impact: 0.10 ac Temporary Impact: 0.04 ac (746 cy) To be filled by proposed track and access road construction Trousdale Road

S005 Permanent Impact: 0.47 ac Temporary Impact: 0.001 ac (2,598 cy) To be filled by proposed track and access road construction Napoleon St. Wetland/WOUS Fill Substrates and Quantities Substrate

5626

1,416

Ba l l a s t Fi l l

17946

2,316

Ri p Ra p Fi l l Total:

10876 0

34,448

1,726 12

5,470

Permanent and Temporary Wetland/WOUS Impacts Wetland/WOUS

Permanent Impact Acreage Temporary Impact Acreage

Pa l us tri ne Needl e-Lea ved Deci duous Fores ted (PFO2)

4.86

0.18

Pers i s tent Pa l us tri ne Emergent (PEM1)

0.23

0.06

Pa l us tri ne Broa d-Lea ved Deci duous Fores ted (PFO1)

0.14

Pa l us tri ne Broa d-Lea ved Deci duous Shrub-Scrub (PSS1) 0.71 Dra i na ge Di tch/Ephemera l Strea m

0.67

Total:

6.91

Ma nma de Pond

Grading Limits

Existing Bridge

Road Centerline

Existing Culvert

Existing Access Road Proposed Track

Proposed Culvert ????

0.30

Existing Right of Way Existing Track

Proposed Surface Flow Road Improvement

90 ¥

WOUS Fill Quantity (CY)

Ea rthen Fi l l

Subba l l a s t Fi l l

R:\GIS\HOU\UPRR\Lockmoor\MapFiles\Permit\Lockmoor_Permit_DataDriven.mxd - 2/11/2014 @ 10:16:13 AM

Wetland Fill Quantity (CY)

S002 Permanent Impact: 0.14 ac Temporary Impact: 0.02 ac (877 cy) To be filled by proposed track and access road construction

0.02 0.11 0.03

0.001 0.40

February 11, 2014

Signal Case

Potential Jurisdictional Waters of the U.S. Potential Jurisdictional Wetlands Pond

Permanent Workspace Temporary Workspace

0

¯ Feet 1 in = 200 ft

Plan View UPRR Lockmoor Yard Expansion, Lafayette Subdivision MP 224.35 to MP 222.98

3

200

4

5

6

7

8

© OpenStreetMap (and) contributors, CC-BY-SA

Figure 1 Sheet 7 of 13

9

Calcasieu Parish W2 Permanent Impact: 0.14 ac Temporary Impact: 0.02 ac (900 cy) To be filled by proposed track and access road construction W4 Permanent Impact: 0.01 ac Temporary Impact: 0.02 ac (139 cy) To be filled by access road construction

Proposed Culvert (See Sheet 12)

S002 Permanent Impact: 0.14 ac Temporary Impact: 0.02 ac (877 cy) To be filled by proposed track and access road construction

Trousdale Road

Trousdale ???????? ???????? ???????? ???????? ???????? ???????? ???????? ???????? ????????

W3 Permanent Impact: 0.61 ac Temporary Impact: 0.05 ac (3,606 cy) To be filled by proposed track and access road construction

Wetland/WOUS Fill Substrates and Quantities Substrate

5626

1,416

Ba l l a s t Fi l l

17946

2,316

Ri p Ra p Fi l l Total:

10876 0

34,448

1,726 12

5,470

Permanent and Temporary Wetland/WOUS Impacts Wetland/WOUS

Permanent Impact Acreage Temporary Impact Acreage

Pa l us tri ne Needl e-Lea ved Deci duous Fores ted (PFO2)

4.86

0.18

Pers i s tent Pa l us tri ne Emergent (PEM1)

0.23

0.06

Pa l us tri ne Broa d-Lea ved Deci duous Fores ted (PFO1)

0.14

Pa l us tri ne Broa d-Lea ved Deci duous Shrub-Scrub (PSS1) 0.71 Dra i na ge Di tch/Ephemera l Strea m

0.67

Total:

6.91

Ma nma de Pond

Grading Limits

Existing Bridge

Road Centerline

Existing Culvert

Existing Access Road Proposed Track

Proposed Culvert ????

0.30

Existing Right of Way Existing Track

Proposed Surface Flow Road Improvement

90 ¥

WOUS Fill Quantity (CY)

Ea rthen Fi l l

Subba l l a s t Fi l l

R:\GIS\HOU\UPRR\Lockmoor\MapFiles\Permit\Lockmoor_Permit_DataDriven.mxd - 2/11/2014 @ 10:16:15 AM

Wetland Fill Quantity (CY)

Napoleon St.

0.02 0.11 0.03

0.001 0.40

February 11, 2014

Signal Case

Potential Jurisdictional Waters of the U.S. Potential Jurisdictional Wetlands Pond

Permanent Workspace Temporary Workspace

0

¯ Feet 1 in = 200 ft

Plan View UPRR Lockmoor Yard Expansion, Lafayette Subdivision MP 224.35 to MP 222.98

3

200

4

5

6

7

8

© OpenStreetMap (and) contributors, CC-BY-SA

Figure 1 Sheet 8 of 13

9

Calcasieu Parish

W2 Permanent Impact: 0.14 ac Temporary Impact: 0.02 ac (900 cy) To be filled by proposed track and access road construction S003 Permanent Impact: 0.01 ac Temporary Impact: 0.004 ac (63 cy) To be filled by access road construction S001 No Impacts Trousdale Road ???????? ???????? ?

?

POE Latitude: 30°14'17.391" N Longitude: 93°16'59.729" W

?

W1 Permanent Impact: 0.17 ac Temporary Impact: 0.03 ac (1,108 cy) To be filled by proposed track and access road construction

Wetland/WOUS Fill Substrates and Quantities Substrate

5626

1,416

Ba l l a s t Fi l l

17946

2,316

Ri p Ra p Fi l l Total:

10876 0

34,448

1,726 12

5,470

Permanent and Temporary Wetland/WOUS Impacts Wetland/WOUS

4.86

0.18

Pers i s tent Pa l us tri ne Emergent (PEM1)

0.23

0.06

Pa l us tri ne Broa d-Lea ved Deci duous Fores ted (PFO1)

0.14

Pa l us tri ne Broa d-Lea ved Deci duous Shrub-Scrub (PSS1) 0.71 Dra i na ge Di tch/Ephemera l Strea m

0.67

Total:

6.91

Grading Limits

Existing Bridge

Road Centerline

Existing Culvert

Existing Access Road Proposed Track

Proposed Culvert ????

0.30

Existing Right of Way Existing Track

Proposed Surface Flow Road Improvement

10 ¥

Permanent Impact Acreage Temporary Impact Acreage

Pa l us tri ne Needl e-Lea ved Deci duous Fores ted (PFO2)

Ma nma de Pond

90 ¥

WOUS Fill Quantity (CY)

Ea rthen Fi l l

Subba l l a s t Fi l l

R:\GIS\HOU\UPRR\Lockmoor\MapFiles\Permit\Lockmoor_Permit_DataDriven.mxd - 2/11/2014 @ 10:15:40 AM

Wetland Fill Quantity (CY)

Napoleon St.

10 ¥

0.02 0.11 0.03

0.001 0.40

February 11, 2014

Signal Case

Potential Jurisdictional Waters of the U.S. Potential Jurisdictional Wetlands Pond

Permanent Workspace Temporary Workspace

0

¯ Feet 1 in = 200 ft

Plan View UPRR Lockmoor Yard Expansion, Lafayette Subdivision MP 224.35 to MP 222.98

3

200

4

5

6

7

8

© OpenStreetMap (and) contributors, CC-BY-SA

Figure 1 Sheet 9 of 13

9

Proposed Tracks

Existing Ground

Proposed Embankment

Proposed Swale

Existing Track Centerline

Wetland

TYPICAL EMBANKMENT SECTION - SWALE REQUIRED

Proposed Embankment Existing Ground

Wetland

Existing Track Centerline

TYPICAL EMBANKMENT SECTION - SWALE NOT REQUIRED POST-CONSTRUCTION DRAINAGE FLOW CASES. 1. EXISTING SHEETFLOW AWAY FROM TRACKS WITH NO EXISTING SWALE: PROPOSED EMBANKMENT PROVIDES SHEET FLOW AWAY FROM TRACKS MATCHING EXISTING DRAINAGE CONDITION. NO SWALE REQUIRED PER HYDROLOGY AND HYDRAULICS ANALYSIS. 2. PROPOSED GRADING IMPACTING EXISTING SWALE PROPOSED EMBANKMENT LOCATED WITHIN LIMITS OF EXISTING SWALE REQUIRES PROPOSED SWALE TO BE RELOCATED ALONG THE OUTSIDE OF PROPOSED EMBANKMENT SLOPE. PROPOSED SWALE SIZED ACCORDING TO CALCULATIONS PER HYDROLOGY AND HYDRAULICS ANALYSIS. ES121313053030SAC

FEBRUARY 11, 2014

UPRR LOCKMOOR YARD EXPANSION PROJECT TYPICAL CROSS SECTION THROUGH WETLANDS SHEET 10 of 13

TYPICAL SECTION FOR ACCESS ROAD

TYPICAL SECTION FOR STORAGE TRACKS

UPRR LOCKMOOR YARD EXPANSION PROJECT FEBRUARY 11, 2014 ES121313053030SAC

TYPICAL TRACK CROSS SECTION SHEET 11 of 13

Existing Ground

TYPICAL SECTION FOR STORAGE TRACK

UPRR LOCKMOOR YARD EXPANSION PROJECT FEBRUARY 11, 2014 ES121313053030SAC

TYPICAL TRACK CROSS SECTION SHEET 12 of 13

EXISTING GROUND LINE 6" ROAD BASE MATERIAL

PROPOSED 24"x50' CMP CULVERT

DRIVEWAY CULVERT SECTION

Proposed 72"x170' CMP Culvert

Existing Ground

Proposed 72"x90' SSP Culvert

Centerline Proposed Track Proposed Future Tracks

Class 2 RipRap at Outlet Existing Track Centerline

CULVERT 224.26 SECTION

UPRR LOCKMOOR YARD EXPANSION PROJECT FEBRUARY 11, 2014 ES121313053030SAC

CULVERT CROSS SECTION SHEET 13 of 13

Rough impact

We use the fields in this section to decide whether to conduct an in-depth review.

Permit Manager

Dates

Identity numbers

Permits, certifications, and locations related to this particular notice

History of edits

Data are available as CSV download in the following schemas