You can copy from here when filling out the rest of the page.
Devils Ditch (Richland County)
Devils Ditch (Richland County)
JOINT
PUBLIC NOTICE
CHARLESTON DISTRICT, CORPS OF ENGINEERS
69A Hagood Avenue
Charleston, South Carolina 29403-5107
and
THE S.C. DEPARTMENT OF HEALTH AND ENVIRONMENTAL CONTROL
Office of Environmental Quality Control
Water Quality Certification and Wetlands Programs Section
2600 Bull Street
Columbia, South Carolina 29201
REGULATORY DIVISION
Refer to: PIN# 2010-1389-6F
March 6, 2014
Pursuant to Sections 401 and 404 of the Clean Water Act (33 U.S.C. 1341), an application has been
submitted to the Department of the Army and the South Carolina Department of Health and Environmental Control
by
Richland County Stormwater Department
c/o Marcus Sizemore
Dennis Corporation
410 Mill Street, Suite 401
Mount Pleasant, SC 29464
for a permit to place fill material in
DEVILS DITCH
At a location between S. Bonham Road arid S. Beltline Boulevard, Richland County, South Carolina. (Latitude
33.974553 N Longitude 80.991763 W)
In order to give all interested parties an opportunity to express their views
NOTICE
is hereby given that written statements regarding the proposed work will be received by the Corps until
15 Days from the Date of this Notice,
and SCDHEC will receive written statements regarding the proposed work until
30 Days from the Date of this Notice
from those interested in the activity and whose interests may be affected by the proposed work.
The proposed work consists of the placement of rip-rap and armoring in a tributary. In detail, the work
·consists of placing rip-rap, armoring, and toe reinforcements for maintenance and stabilization in 845 linear feet of
Devils Ditch. According to the applicant, the maintenance and stabilization is to address water quality concerns,
particularly runoff and trash/debris that has built up over years. The applicant has stated that the activity will result
in minimal individual and cumulative adverse impacts and has not proposed mitigation at this time. The District
Engineer has not reached a decision as to the applicant's request to waive the mitigation requirement.
According to the applicant, the project purpose is to address water quality concerns in the area through
maintenance and stabilization.
REGULATORY DIVISION
Refer to: PIN# 2010-1389-6F
March 6, 2014
The District Engineer has concluded that the discharges associated with this project, both direct and
indirect, should be reviewed by the South Carolina Department of Health and Environmental Control in
accordance with provisions of Section 401 of the Clean Water Act. As such, this notice constitutes a request, on
behalf of the applicant, for certification that this project will comply with applicable effluent limitations and water
quality standards. The District Engineer will not process this application to a conclusion until such certification is
received. The applicant is hereby advised that supplemental information may be required by the State to facilitate
the review. Persons wishing to comment or object to Water Quality Certification must submit all comments in
writing to the S.C. Department of Health and Environmental Control at the above address within thirty (30) days of
the date of this notice.
This notice initiates the Essential Fish Habitat (EFH) consultation requirements of the Magnuson
Stevens Fishery Conservation and Management Act. Implementation of the proposed project would impact
freshwater habitat upstream of estuarine substrates and emergent wetlands utilized by various life stages of
species comprising the red drum, shrimp, and snapper-grouper management complexes. Our initial
determination is that the proposed action would not have a substantial individual or cumulative adverse impact
on EFH or fisheries managed by the South Atlantic Fishery Management Council and the National Marine
Fisheries Service (NMFS). Our final determination relative to project impacts and the need for mitigation
measures is subject to review by and coordination with the NMFS.
Pursuant to Section ?(c) of the Endangered Species Act of 1973 (as amended), the District Engineer has
consulted the most recently available information and has determined that the project is not likely to adversely
affect any Federally endangered, threatened, or proposed species or result in the destruction or adverse
modification of designated or proposed critical habitat. This public notice serves as a request for written
concurrence from the U.S. Fish and Wildlife Service and/or the National Marine Fisheries Service on this
determination.
Pursuant to Section 106 of the National Historic Preservation Act (NHPA), this public notice also
constitutes a request to Indian Tribes to notify the District Engineer of any historic properties of religious and
cultural significance to them that may be affected by the proposed undertaking.
In accordance with the NHPA, the District Engineer has also consulted the latest published version of
the National Register of Historic Places for the presence or absence of registered properties, or properties
listed as being eligible for inclusion therein, and this worksite is not included as a registered property or
property listed as being eligible for inclusion in the Register. To insure that other cultural resources that the
District Engineer is not aware of are not overlooked, this public notice also serves as a request to the State
Historic Preservation Office to provide any information it may have with regard to historic and cultural
resources.
Any person may request, in writing, within the comment period specified in this notice, that a public hearing
be held to consider this application. Requests for a public hearing shall state, with particularity, the reasons for
holding a public hearing.
The decision whether to issue a permit will be based on an evaluation of the probable impact including
cumulative impacts of the activity on the public interest and will include application of the guidelines promulgated
by the Administrator, Environmental Protection Agency (EPA), under authority of Section 404(b) of the Clean
Water Act and, as appropriate, the criteria established under authority of Section 102 of the Marine Protection,
Research and Sanctuaries Act of 1972, as amended. That decision will reflect the national concern for both
protection and utilization of important resources. The benefit which reasonably may be expected to accrue from
the project must be balanced against its reasonably foreseeable detriments. All factors which may be relevant to
the project will be considered including the cumulative effects thereof; among those are conservation, economics,
aesthetics, general environmental concerns, wetlands, historic properties, fish and wildlife values, flood hazards,
flood plain values, land use, navigation, shoreline erosion and accretion, recreation, water supply and
REGULATORY DIVISION
Refer to: P/N # 201 0-1389-6F
March 6, 2014
conservation, water quality, energy needs, safety, food and fiber production and, in general, the needs and welfare
of the people. A permit will be granted unless the District Engineer determines that it would be contrary to the
public interest. In cases of conflicting property rights, the Corps of Engineers cannot undertake to adjudicate rival
claims.
The Corps of Engineers is soliciting comments from the public; Federal, state, and local agencies and
officials; Indian Tribes; and other interested parties in order to consider and evaluate the impacts of this activity.
Any comments received will be considered by the Corps of Engineers to determine whether to issue, modify,
condition or deny a permit for this project. To make this decision, comments are used to assess impacts on
endangered species, historic properties, water quality, general environmental effects, and the other public interest
factors listed above. Comments are used in the preparation of an Environmental Assessment and/or an
Environmental Impact Statement pursuant to the National Environmental Policy Act. Comments are also used to
determine the need for a public hearing and to determine the overall public interest of the activity.
If there are any questions concerning this public notice, please contact Kristin Riegel at 803-253-3903.
Location Map
Prepared for:
Project Location
Devils Ditch Maintenance Project
Columbia, SC
0
2,000 4,000
8,000
Feet
Richland County, ESRI and Denms
·-==--=::::::1----·
Data Sources
1
~Devils
C"l\.~
nn.An
... "',....._ -
Ditch
Prepared by:
IIIJEjl\la&MI
&A-'ri~
CORP[JRATIDN
1
I
I
E4
E2
E7
,/
APPLICATION BY RICHLAND COUNTY
PROJECT#· CPS11103
SAC#· 2010-1389
DEVILS DITCH REHABILITATION PROJECT
RICHLAND COUNTY, SC
DATE·
02/14
INITIALS· RKT
REVISION DATE· 02-28-2014
SAC-201 0-1389-6F
_.
mg?
~m.
=
II 0en
Iq
v.> ~
0"1
::0
0
0
....
.,
.2.
fl
0-..j "
0
Devils Ditch Maintenance Plan
for
Richland County Public Works
February 2014
Richland County
South Carolina
Sheet 2 of 12
USAGE EXHIBIT
KEY PLAN
1800 Huger Street- Columbia, SC 29201 -803.252.0991
PLACE 105.0 CY CLASS C RIPRAP
PIPE END TREATMENT AND CHANNEL
BED LINING (60'L X 18.5'W) W/
GEOTEXTILE UNDERLAYMENT.
IMPACTS =
54.0 LF
Stormdrain Dl
Rim 190.48
lnv Out 188.50
Stormdrain Dl
Rim 190.46
lnv In 188.41
lnv Out 188.35
\
\
~·tormdrain
Dl
Rim 190.69
lnV\In 188.37
lnv 0'4t 188.09
0.-
\
Stormdralh Dl
Rim 190.80
lnv In 188.2p
lnv Out 187.7'\
&.
'G)
P.O.B. MAINLINE
101+50
\
·
....
~
~
.,.... ......
.,.,....,...
----...........------
...,..,..
48" RCP
lnv Out 184.92
........................
Stormdrain Dl
Rim 191.85
lnv 187.30
---- b,'O
APPLICATION BY RICHLAND COUNTY .
PROJECT#· CPS11103
SAC#· 2010-1389
DEVILS DITCH REHABILITATION PROJECT
RICHLAND COUNTY, SC
DATE·
02/14
INITIALS· RKT
REVISION DATE· 02-28-2014
mg!
"->~
.....
I
=
II
.j>.
q
::0
(/)
~
(I)
I
0
0
.,
..... .2.
0
0
(I)
~
188
184
184
180
[-~~-~~+-····i
180
176
L..........·..L...·.·.·..·L ...,.L:. . L .·)
176
48" RCP
lnv Out 184.93
. . . . . . . . . . . . . . . ...,;/~c,'?
:~
188
0
20
HORIZONTAL: 1: 10
VERTICAL: 1: 2
IMPACTS
-CY OF
-CY OF
-CY OF
-CY OF
THIS SHEET
CLASS B RIPRAP· 0.0
CLASS C RIPRAP· 71.0 <54 LF)
ARMORING· 0.0
IMPACTS TOTAL
-CY OF CLASS B RIPRAP· 27.5 <88 LF)
-CY OF CLASS C RIPRAP· 340.0 <282 LF)
-CY OF ARMORING: 101.0 <425 LF>
-CY OF TOE REINFORCEMENT· 30.0 (50 LF)
Devils Ditch Maintenance Plan
for
Richland County Public Works
--.1
February 2014
-20
Richland County
South Carolina
USACE EXHIBIT
1 of 9
LE.U.Eb!.D.
~
CLASS B RIPRAP
CLASS C RIPRAP
BANK ARMORINGliE
rt5KI~
[u;;y;y?"dd
liEBANK ARMORING·
GROUTED CLASS B RIPRAP
SAC-2010-1389-6F
Sheet 3 of 12
CCRPCRATICN
1800 Huger Street- Columbia, SC 29201 - 803.252.0991
'"~
S!A.
,_ '~-o9
I
-/>
200+50
.
/
PLACE 1.39.0 CY CLA'SS C RIPRAP
PIPE END TREATMENT AND
CHANNEL BED LINING! (80'L X 18'W)
W/ GEOTEXTILE UNO~RLAYMENT.
IMPACTS =
78 0
/
/
/
/
.
I // ///// /
I
iP.O.B.
/
/
/
//
r
V
/
184
184
\
·
i
It(/:-; I
.
i-T··-f~c.Ot·~j
L~_LkJ ~j_J
-20
BRANCHLINE
STA: 200+00.00
N: 780,262.5{)
E: 2,002,432.44
r
188
180
62.0 t:Y
/
188
i'
0
180
20
HORIZONTAL: 1:10
VERTICAL: 1:2
I
/APPLICATION BY RICHLAND COUNTY
PROJECT#· CPS11103
SAC#· 2010-1389
DEVILS DITCH REHABILITATION PROJECT
RICHLAND COUNTY, SC
DATE·
02/14
INITIALS· RKT
REVISION DATE· REVISION DATE· 02-28-2014
m'!l
Wffi
...
I
II
-1»
q
::0
en
*I
...
0
0
0
0
,
.2.
a
IMPACTS THIS SHEET
-CY OF CLASS B RIPRAP· 0.0 Devils Ditch Maintenance Plan
for
Richland County Public Works
-.J
February 2014
Richland County
South Carolina
USACE EXHIBIT
2 of9
L.EWill
~
CLASS B RIPRAP
CLASS C RIPRAP
BANK ARMORINGlli
tt5K!>KI2N?\l
tWBi"Y"dl
·BANK ARMORING·
GROUTED CLASS B RIPRAP
SAC-2010-1389-6F
Sheet 4 of 12
CORPORATION
1800 Huger Street- Columbia, SC 29201. 803.252.0991
TOP OF BANK
(TYP)
(J)
..t
N
+
-.:t
r,i,O!J/'."J/(
TIE EQUALITY
MAINLINE TIE
STA: 103+07.18
P.O.E. BRANCHLINE
STA: 203+91.46
N: 780,185.97 /
E: 2, 002,772.13/
tO
·..-.
·~C?> fb
/;
c......, ~·"
"'~"'
'0-1-
1..
t'l
0
PLACE 265.0 CY CLASS C RIPRAP
CHANNEL BED LINING (50'L X 20'W)
W/ GEOTEXTILE UNDERLAYMENT IN
ALL THREE (3) DIRECTIONS FROM
TIE EQUALITY AS SHOWN.
IMPACTS =
150.0 LF.
207.0
..-
-., I
~
~;
:/'
/
// .
'"'"J~
,/
>/. > .
."
/
.
/,.,. "
:-·:·
. /
. ,. .-',
f..
.
·/
.
.../··
/
/.
/
'/
·e;<
/
··.·J'
.
/>
/. / '
.;{
1
/'(/)
" ..
~<;O~·>·
.
0
//'--
.·.
/
/
...,
.../
·-·
104+00
-···~-·-·~
188
... 188
,?!_
-· 0
\J
184
~··
/
\
'c9'? / .
184
"··
180 ,......... f-.. ..t.:.......-t..... +··Y --1 180
>
f)..+.~-.l.·-·"'
17.6
···/
176
zo3+36.">3
-20
TOP OF B
(TYP)
.APPLICATION BY RICHLAND COUNTY
I PROJECT#· CPS11103
SAC#· 2010-1389
DEVILS DITCH REHABILITATION PROJECT
RICHLAND COUNTY, SC
DATE·
02/14
INITIALS· RKT
REVISION DATE· REVISION DATE· 02-28-2014
. . . I 841
;:u
m~lug
oo
=w
~!!.
~iD
q
...:...2.
!='~
~
IMPACTS
-CY OF
-CY OF
-CY OF
-CY OF
IMPACTS TOTAL
-CY OF CLASS B RIPRAP· 27.5 (88 LF)
-CY OF CLASS C RIPRAP· 340.0 <282 LF)
-CY OF ARMORING· 101.0 <425 LF>
-CY OF TOE REINFORCEMENT· 30.0 <50 LF>
Devils Ditch Maintenance Plan
for
Richland County Public Works
February 2014
ANK
THIS SHEET
CLASS B RIPRAP· 0.0
ARMORING· 0.0 (0 LF>
TOE REINFORCEMENT· 0.0 Richland County
South Carolina
USAGE EXHIBIT
3 of9
0
20
HORIZONTAL: 1:10
VERTICAL: 1: 2
~
~
rt)KI~
[~
CLASS B RIPRAP
CLASS C RIPRAP
BANK ARMORING*
*BANK ARMORING·
GROUTED CLASS B RIPRAP
SAC-2010-1389-6F
Sheet 5 of 12
CORPORATION
1800 Huger Street- Columbia, SC 29201 -803.252.0991
II
II
())
.
II
N
18" RCP
lnv Out 177.84 ~~
(!)
+
QJ
Stormdrain
~
~
JB
(/)
m 186.15
II
II
II
II
II
INSTALL 146.0 CY
CLASS C RIPRAP BANK
ARMORING THIS AREA.
144.0 LF
IMPACTS =
32.0 CY
0
II
II
II
II
II
II
42" RCP
i
&
(f)"
1\,
'1
,..._8>
<:_,,/ lnv Out 17?-31
..
' ........................... .....
PLACE 11.0 CY CLASS B
RIPRAP PIPE END TREATMENT
WITH 16'L X 12'W APRON W/
GEOTEXTILE UNDERLA YMEN T.
IMPACTS =
19.0 LF
10.0 CY
',>,
',:',
'','-.,
' ..
'><_v
110+00
_.
184
0
,~---,--"~,-,_--,---,--~ 1
184
(1)
~
TOP OF BANK
(TYP)
s·_.
~
l-4-\i---t------+--r-+---l 180
,----; l ~f--JLt~~
176 H--~+ ~ I -1 176
!
!
I
180
1
l
I
l
vok>
: OHM'\
, I -==t'
cb ,: - i~---1I
r--
.?
~
172
.l(
~
-~
APPLICATION BY RICHLAND COUNTY
PROJECT#· CPS11103
SAC#· 2010-1389
DEVILS DITCH REHABILITATION PROJECT
RICHLAND COUNTY, SC
DATE·
02/14
INITIALS· RKT
REVISION DATE· REVISION DATE· 02-28-2014
. . I ~£.
m'!] lu£
·
ad
~CD
-
0
;u
.,
~~
IMPACTS THIS SHEET
-CY OF CLASS B RIPRAP· 10.0 <19 LD
-CY OF CLASS C RIPRAP· 0.0
IMPACTS
-CY OF
-CY OF
-CY OF
-CY OF
TOTAL
CLASS B RIPRAP· 27.5 <88 LF)
CLASS C RIPRAP· 340.0 <282 LF)
ARMORING: 101.0 <425 LF>
TOE REINFORCEMENT· 30.0 (50 LF)
Devils Ditch Maintenance Plan
for
Richland County Public Works
~
February 2014
Richland County
South Carolina
USAGE EXHIBIT
4 of9
~
~
CLASS B RIPRAP
CLASS C RIPRAP
BANK ARMORINGliE
fi5RDKQfS1?11
[
PP"65'YY1
liEBANK ARMORING·
GROUTED CLASS B RIPRAP
SAC-2010-1389-6F
Sheet 6 of 12
CCRPCRATICJN
1800 Huger Street· Columbia, SC 29201 - 803.252.0991
INSTALL 65.0 CY
·-cLASS C RIPRAP BANK
ARMORING THIS AREA.
IMPACTS =
78.0 LF
3
66
111+ 4 '
17.0 CY
114+50
176
176
172
16 8
~
Y.
_.
_.
INSTALL 86.0 CY
CLASS C RIPRAP BANK
ARMORING THIS AREA.
IMPACTS =
105.0 LF
21.0 CY
0
+
~
·_.
6\
INSTALL 38.0 CY
CLASS C RiPRAP BANK
ARMORING THIS AREA.
IMPACTS =
46.0 LF
10.0 CY
1
1
~
CY
L~.L:.___L_::__.L.__l
-2o
o
//
.2o
H9RIZONTAL:r 1:10
. VERTICAL:.
2
·p:
'\)'.
~
...._
...._
!'
16 8
INSTALL 43.0 CY
CLASS C RIPRAP BANK
ARMORING THIS AREA.
IMPACTS =
52.0 LF
21.0 CY
-;~><·
!
)(
'\'\1.:
~-
<(\ S'\ 18" RCP
It;
CB~~
Stormdrain
Rim 177.55
Throat 176.70
lnv Out 175.05
CV/1
-~
..
;:s·
·52
.->
'-?··
0\
/~
"+
Q:
APPLICA TIDN BY RICHLAND COUNTY
PROJECT#· CPS11103
SAC#· 2010-1389
DEVILS DITCH REHABILITATION PROJECT
RICHLAND COUNTY, SC
DATE·
02/14
INITIALS· RKT
REVISION DATE· REVISION DATE· 02-28-2014
m'!l
O'l!!
...=
Iq
II
.j>.
;lJ
en
""'ar
.,
0
0
~
-- .!2.
<1>
0
fl.
I0
·~
IMPACTS THIS SHEET
-CY OF CLASS B RIPRAP· 0.0
-CY OF CLASS C RIPRAP· 0.0
-CY OF ARMORING· 69.0 <281
-CY OF TOE REINFORCEMENT·
(0 LF>
(0 LF>
LF)
0.0 IMPACTS TOTAL
-CY OF CLASS B RIPRAP· 27.5 (88 LF)
-CY OF CLASS C RIPRAP· 340.0 (282 LF)
-CY OF ARMORING· 101.0 (425 LF>
-CY OF TOE REINFORCEMENT· 30.0 (50 LF>
Devils Ditch Maintenance Plan
for
Richland County Public Works
USACE EXHIBIT
5of9
I...E.U.E.IiD.
~
CLASS B RIPRAP
CLASS C RIPRAP
BANK ARMORING*
f15KI>Kkf'k11
[ w;:y:;;:s:yj1
*BANK ARMORING·
GROUTED CLASS B RIPRAP
SA C-20 10-1389-6F
Sheet 7 of 12
CORPORATION
-.J
February 2014
Richland County
South Carolina
1800 Huger Street- Columbia, SC 29201 - 803.252.0991
~
"':
~"··..l·
.:::··;,'.";; \~/:~""' '
'>'<: ,, \
~i'. '~
TOP OF BANK
(TYP)
V.'"<·-0
'\.~·<".>_
·,,
',
'C, .
~ Q\,·.~:,,>
' ':;.., ·
~- \'\ ~,,,.,
(QV)
~
PLACE 2.5 CY CLASS 8 RIPRAP PIPE
END TREATMENT WITH 8'L X 6'W
APRON W/ GEOTEXTILE
UNDERLAYMENT.
IMPACTS =
9.0 LF
2.0 CY
fr
';)<:
....._~/
PLACE 1.5 CY CLASS B RIPRAP 6'L X 4',W
APRON W/ GEOTE<\116+50
180
180
~,
\
,,,
\
1;
ll .,
176
176
172
172
'1;
I;
I;
I;
1;
//l:t
;~;/ l1a"
;/
168
,/1
r/!.1
168
-20
0
20
HORIZONTAL: 1:10
VERTICAL: 1:2
I
mgl
-.....Jffi.
I
II
.j>.
q
::0
(/J
lil
iD
0
0
I c.
~
0
.,
~
..Q.
Cl>
0.
IMPACTS THIS SHEET
-CY OF CLASS B RIPRAP· 2.5 <13 LD
-CY OF CLASS C RIPRAP· 0.0
IMPACTS TOTAL
-CY OF CLASS B RIPRAP· 27,5 <88 LD
-CY OF CLASS C RIPRAP· 340.0 <282 LF)
-CY OF ARMORING: 101.0 <425 LF)
-CY OF TOE REINFORCEMENT· 30.0 <50 LD
Devils Ditch Maintenance Plan
for
Richland County Public Works
-...!
February 2014
""·
}:>.
/
APPLICATION BY RICHLAND COUNTY
PROJECT#· CPS11103
SAC#· 2010-1389
DEVILS DITCH REHABILITATION PROJECT
RICHLAND COUNTY, SC
I DATE·
02/14
INITIALS· RKT
I REVISION DATE· REVISION DATE· 02-28-2014
....=
RCP
lnv Out 176.46
Richland County
South Carolina
USAGE EXHIBIT
6 of9
L..E.G.END.
~
rt)KI~
[~
CLASS B RIPRAP
CLASS C RIPRAP
BANK ARMORING*
*BANK ARMORING·
GROUTED CLASS B RIPRAP
SAC-2010-1389-6F
Sheet 8 of 12
CORPORATION
1800 Huger
Street~
Columbta, SC 29201 - 803.252.0991
I
I
INSTALL 13.0 CY
TOE REINFORCEMENT
THIS AREA.
.
(:J"
1};1_f ACTS =
2l.Q LF ;13.0 CYoy
6/
WITH
6'L
PLACE FOUR (3) 1.5 CY CLASS B
RIPRAP PIPE END T~EATMENTS WITH 6'L
X 4'W APR/ONS W/ GEOTEXTILE
UNDERLA YMENT.
IMPACTS =
0.0 LF
.
0.0 CY
.......
.......
Lf)
.q
"-·· ..
,_.:
L[)
+
/~
~
i~
'·
'
N·~
~
J
Q
If
Q
Q
I
'1...-.~~
1
Q
Q
Q
Q
Q
Stormdrain CB
Q
Q
Rim 172.40
Q
Throat 171.90
lnv Out 170.00
Q
Q
Q
Q
l' ' I
'tb~
Q!
Q)
Q
.. :
'"'·
--:->
.
18" RCP
'
lnv Out 169.74
lnv In N/L
18" RCP
lnv Out 169.07
Stormdrain CB
Rim 172.41
Throat 171.69
lnv Out 169.71
\
18" RCP .........
lnv Out 167.6'2 /
Stormdrain CB
Rim 170.93
Throat 170.17
lny.Out 167.53
Q
Q
~
-20
0
20
HORIZONTAL: 1: 10
VERTICAL: 1: 2
APPLICATION BY RICHLAND COUNTY
PROJECT#· CPS11103
1 SAC#·
2010-1389
DEVILS DITCH REHABILITATION PROJECT
RICHLAND COUNTY, SC
DATE·
02/14
INITIALS· RKT
REVISION DATE· REVISION DATE· 02-28-2014
.
~
m'!l
CP![
= en
II 0
;:u
0
0
I *I0
.J>.
q
~
0
'U
.2.
"'
!4
IMPACTS THIS SHEET
-CY OF CLASS B RIPRAP· 0.5 <4 LF>
-CY OF CLASS C RIPRAP· 0.0
-CY OF TOE REINFORCEMENT· 13.0 <21 LF)
IMPACTS TOTAL
-CY OF CLASS B RIPRAP· 27.5 <88 LF)
-CY OF CLASS C RIPRAP· 340.0 <282 LF>
-CY OF ARMORING· 101.0 <425 LF>
-CY OF TOE REINFORCEMENT· 30.0
Devils Ditch Maintenance Plan
for
Richland County Public Works
USACE EXHIBIT
7 of9
I..EW:ill
~
tl)KI~
[~
CLASS B RIPRAP
CLASS C RIPRAP
BANK ARMORING·
·BANK ARMORING·
GROUTED CLASS B RIPRAP
SAC-2010-1389-6F
Sheet 9 of 12
CORPClR.A.TIClN
-.1
February 2014
Richland County
South Carolina
1800 Huger Street- Columbia, SC 29201 · 803.252.0991
24" RCP
lnv Out 1.~6.16
INSTALL 17.0 cY TOE
REINFORCEMENT THIS AREA
IMPACTS =
29.0 LF
/
17.0 CY
-------,_
Stormdrain Dl
Rim 170.58
---,_
/
PLACE 2.5 CY CLA~S B.PiPRAP PIPE\
END TREATMENT WITH 8'L.X 6'W
\
AP,RON W/ GEOTEXTILE
.
UNDERLAYMEN~
IMPACTS =
6.0 LF
0.5 rv
--~
-'0
?.
-~-"'
TOP oe.-tlANK
(!Y~}
-"Stormdrain CB
Rim 168.06
Throat 167.30
lnv In 165.96
lnv Out 165.96
-~~--
172
CLASS B RIPRAP
168
18"
GEOTEXTILE UNDERLAYMENT.
11.0 LF
2.0 CY
1/
u.::J
u
. UHMi
'"'""
,,/'
APPLICATION BY RICHLAND COUNTY
PROJECT#· CPS11103
SAC#· 2010-1389
DEVILS DITCH REHABILITATION PROJECT
RICHLAND COUNTY, SC
DATE·
02/14
INITIALS· RKT
REVISION DATE· REVISION DATE· 02-28-2014
en
~
I~~.2.
c.!
~
~en
m~1~~£
c.o~
~iii
o"''
!='~
IMPACTS
-CY OF
-CY OF
-CY OF
-CY OF
THIS SHEET
CLASS B RIPRAP· 3.0 <21 LF>
CLASS C RIPRAP· 0,0 (0 LF>
ARMORING· 0.0
TOE REINFORCEMENT· 17.0 (29 LF)
IMPACTS
-CY OF
-CY OF
-CY OF
-CY OF
TOTAL
CLASS B RIPRAP· 27.5 <88 LF>
CLASS C RIPRAP· 340.0 <282 LF)
ARMORING: 101.0 <425 LD
TOE REINFORCEMENT· 30.0 <50 LF>
Devils Ditch Maintenance Plan
for
Richland County Public Works
February 2014
Richland County
South Carolina
USAGE EXHIBIT
8 of9
··~·,; ;-4---+--:-i~-: 164
160 L~L-.L--'~.l.:.__L_L-_: __,__t ____j 160
-40 -20
0
20
40
HORIZONTAL: 1:10
VERTICAL: 1: 2
LEGEND
CLASS B RIPRAP
CLASS C RIPRAP
BANK ARMORING·
~
fl)KD!Sl2f5J?TI
[PhYi5'rtl
·BANK ARMORING·
GROUTED CLASS B RIPRAP
SAC-2010-1389-6F
Sheet 10 of 12
CORPORATION
1800 Huger Street- Columbia, SC 29201 - 803.252.0991
Ill
-+~l---
18" RCP
1 ;~o:Jt'"JI
,
I .I
Ill
Ill
Ill
I'll
Ill
Ill
Ill
ill
ill I
ill I
II I
Ill
-
_
OuJJ.156o4~~
Jov
_l;~fl /
·' j I
/
I
/'~~;,:
Ill
Ill
ill
/
/ ~;)tJ!§lcf./]foC"" ~
!
Ill
nf\
24" RCP
Ill
lnv Out 164084
!
'
Ill
II
Ill
;~ oyf;;;.§£·;/
165013·~/ ~>-~ ;::::::/,;:\~
:;>/_.··
15· RCP
lnv In 1 0
lnv Out 64 94
.
11
24" RCP
i
\ 1\ ( l n v Out 164076
' ·
..._.. ".. · .
;. / ;, /,;%
¢.·
·..
/
:.: ' !'·..,.;.
> / '\
_.
PLACE 11.0 CY CLASS 8 RIPRAP PIPE
END TREATMENT WITH 16'L X 12'W
APRON W/ GEOTEXTILE
UNDERLAYMENT.
IMPACTS =
\:\
~~~
111
III
Ill
II I
~
_.
+01
:tf;f;;,;:·::<: /
.
I KI
II L.
·n_;~.
11
'.t''
/'
1
"-PLACE THREE (.3) 1.5 CY CLASS··B ...
. . ~6~:---i····
·-Q
.
~
UNDERLAYMEN~
15" RCP
lnv In N/L
lnv Out 165o67
__ _
~"··
=
10.0 LF
1.5 CY
-20
Y.
_.
_,. ffi
0 ~
Q
""'"
0
-
20
1:10
VERTA'CAL: 1: 2
I . . =. en I 8-o..2.
II
0
HORIZO~TAL:
APPLICATION BY RICHLAND COUNTY
PROJECT#· CPS11103
SAC#· 2010-1389
DEVILS DITCH REHABILITATION PROJECT
RICHLAND COUNTY, SC
DATE·
02/14
INITIALS· RKT
REVISION DATE· REVISION DATE· 02-28-2014
men
(~0
RIPRAP PiPE END TREATMENTS WITH 6'L
X 4'W APRONS W/ GEOTEXTILE
IM-P.ACTS
_......
·
01
Ill
I II
Ill
·····
RIP~AP
If/.
"''--
N/L~
lnvln
lnv Out 163086
PLACE I. 5 CY CLASS 8
PIPE
::·
END TREATMENT WITH 6'L X 4'W~~/~/
.<:/!:;.:
APRON.:W/ GEOTEXTILE UND_ERLA Y~_EN·T
·...
..,. .,::::~:ff:):.'~f-7..':
/
IMPACTS · 7.0 LF
..- ···· :;::::..;:: ·· :
.
<
0. 0
1~ ~p
'
.
PLAqE 1.5 CY CLASS 8 RIPRAP PIPE---..;._
.~
...
END TREATMENT WITH 6'L X 4'W
/ .. ~~1
APRON W/ GEOTEXTILE
/;/'I.
UNDERLAYMENT.
~f! 1
IMPACTS =
0.0
j
Ill
\
I
Al
_...
o<»~
0
IMPACTS THIS SHEET
-CY OF CLASS B RIPRAP· 11.5 C31 LF)
-CY OF CLASS C RIPRAP· 0.0 CO LF>
-CY OF ARMORING· 0.0 CO LF>
-CY OF TOE REINFORCEMENT· 0.0 CO LF>
IMPACTS TOTAL
-CY OF CLASS B RIPRAP· 27.5 C88 LF)
-CY OF CLASS C RIPRAP· 340.0 C282 LF)
-CY OF ARMORING· 101.0 C425 LF)
-CY OF TOE REINFORCEMENT· 30.0 C50 LF)
Devils Ditch Maintenance Plan
for
Richland County Public Works
0--J
February 2014
Richland County
South Carolina
USAGE EXHIBIT
9 of9
~
~
rt)KI~
CLASS B RIPRAP
CLASS C RIPRAP
BANK ARMORING·
[~
liEBANK ARMORING·
GROUTED CLASS B RIPRAP
SAC-2010-1389-6F
Sheet 11 of 12
CCJRPCJRATICN
1800 Huger Street· Columbia, SC 29201 - 803.252.0991
EROSION CONTROL MATTING
TOE REINFORCEMENT DETAIL
NTS
EXISllNG EROSION
CONTROL MATllNG (TYP)
RIPRAP OUTLET & CHANNEL BED LINING DETAIL
Refer to SCOOT Drawing No. 804-310-00
NTS
UNDERCUT IJOIDS BEHIND ECM SHALL BE
FILLED WITH GROUT AFTER PLACING
RIPRAP (TYP)
VOIDS SHALL BE FILLED WITH
CLASS B RIRRAP TO THE NATURAL
CROSS SECllONAL FLOW LINE OF
THE DITCH AND GROUTED
RIPRAP BANK ARMORING DETAILS
NTS
PLACE CLASS C RIPRAP TO TOP OF
BANK. RIPRAP TO BE GROUTED ONCE
PLACEMENT IS APPROVED BY COUNTY.
APPLICATION BY RICHLAND COUNTY
PROJECT#· CPS11103
SAC#· 2010-1389
DEVILS DITCH REHABILITATION PROJECT
RICHLAND COUNTY, SC
DATE·
02/14
INITIALS· RKT
REVISION DATE· REVISION DATE· 02-28-2014
USE A MAXIMUM 1: 1 SLOPE WHERE
EXIS11NG GROUND SLOPE IS STEEPER.
RIPRAP SHALL BE PYRAMID STACKED IF
NEEDED TO ACHIEVE PROPER SLOPE.
RIPRAP TO BE GROUTED ONCE
PLACEMENT IS APPROVED BY COUNTY.
SAC-201 0-1389-6F
men
:T
~ro
~
Ia
;u
Z en
0
0
(/)
0
I " I 0.....
-! @
~
4'
..2.
ro
fl
Devils Ditch Maintenance Plan
for
Richland County Public Works
February 2014
Richland County
South Carolina
USAGE EXHIBIT
DETAILS
Sheet 12 of 12
CORPORATION