You can copy from here when filling out the rest of the page.
Benny Dean Jr. is the Regulatory point-of-contact for this permit application from H&H Land, LLC, affecting unnamed drainage and wetlands in Eugene, Ore.
PUBLIC NOTICE for Permit Application
Issue Date: March 1, 2013
Expiration Date: March 30, 2013
US Army Corps of Engineers No: NWP-1995-1040-1
30-Day Notice Oregon Department of State Lands No: FP 10573
Interested parties are hereby notified that an application has been received for a Department of the Army permit for certain work in waters of the United States, as described below and shown on the attached plan.
Comments: Comments on the described work should reference the U.S. Army Corps of Engineers number shown above and reach this office no later than the above expiration date of this Public Notice to become part of the record and be considered in the decision. Comments should be mailed to the following address:
U.S. Army Corps of Engineers
Benny A. Dean Jr. (Benny.A.Dean@usace.army.mil)
Eugene Field Office
1600 Executive Pkwy.,Suite 210
Eugene, OR 97401-2156
Applicant: H&H Land LLC
c/o Richard Hunsaker
P.O. Box 2266
Eugene, OR 97402
Location: The project is located at 1455 Westec Dr. in Eugene, Lane Co. Ore. The site is in Section 33 of Township 17 South, Range 4 West.
Waterway: Unnamed Wetlands W1 & W2, and an Unnamed Drainage.
Project Description: The project would excavate up to 2,513 cubic yards of soils and vegetation from 2.282 acres of wetlands and 0.03 acres of a drainage ditch and discharge approximately 10,977 cubic yards of fill to construct three industrial/commercial buildings and associated parking on the 4.4-acre site. The construction project would involve stripping as needed to remove existing vegetation, native silty clay loam and clay soil, and gravel fill. The site would be graded. Fill would be used as needed to level the site and begin construction of driveways, buildings, parking areas, docks, stormwater treatment swales, and utility trenches. Construction would involve use of heavy equipment including an excavator, trackhoe, backhoe, grader, dump trucks, concrete trucks, and asphalt machinery. All fill would be from a clean source local source. The staging area would be in uplands at the south end of the site, located over 150 feet from any adjacent offsite wetlands. Construction access for the work would be from Renne Street along the east property line. Utility trenches would be between 1.5-11 feet deep, with pipe sizes ranging from 3-18 inches in diameter. Municipal water would be provided by the city of Eugene's municipal water system. Sanitary sewage and stormwater would be routed into the city's sanitary and stormwater systems.
Stormwater from the site is proposed to be treated via grassy swales and an Aquashield Aqua-swirl treatment device as shown on the post construction stormwater plan. The grassy swales are located on the western and northern edges of the proposed site and are designed to effectively treat 35% of the impervious surface run off. The swales have been designed to meet the requirements of the City of Eugene Stormwater Management Plan and provide contact time greater than 9.0 minutes. The remaining 65% of impervious surface run off would be treated by the Aquashield Aqua-swirl mechanical treatment device. The device would accept run off from the eastern half of the site prior to entering the existing piped system within the Renne Drive right-of-way.
Mitigation: The applicant has provided a proposed compensatory wetland mitigation plan for filling onsite wetlands and other Non-wetland Waters by purchasing credits from an approved and local Wetland Mitigation Bank or similar mitigation service. Mitigation would be in-kind for Cowardin and HGM class: the impact site contains wetlands in the PEM Cowardin classes as do all of the appropriate wetland mitigation banks/sites. The vast majority of impact site wetland is of the Slope/Flats HGM class, and all of the appropriate wetland mitigation banks/sites are predominantly in the Slope/Flats HGM class.
If a permit is issued, the Corps will determine what is appropriate and practicable compensatory mitigation. The amount of compensatory mitigation required shall be commensurate with the anticipated impacts of the project.
Purpose: The project's purpose is to construct a light industrial facility with appropriate amenities.
Drawings: Six drawings are attached and labeled Corps No. NWP-1995-1040-1 enclosure.
Additional Information: Additional information may be obtained from Mr. Benny A. Dean Jr., Project Manager, U.S. Army Corps of Engineers at (541) 465-6769 or email Benny.A.Dean@usace.army.mil.
Authority: This permit will be issued or denied under the following:
Section 404, Clean Water Act (33 U.S.C. 1344), for discharge of dredged or fill material into waters of the United States.
Water Quality Certification: A permit for the described work will not be issued until certification, as required under Section 401 of the Clean Water Act (P.L. 95‑217), has been received or is waived from the certifying state. Attached is the state's notice advertising the request for certification.
Section 404(b)(1) Evaluation: The impact of the activity on the public interest will be evaluated in accordance with the Environmental Protection Agency guidelines pursuant to Section 404(b)(1) of the Clean Water Act.
Public Hearing: Any person may request in writing within the comment period specified in this notice that a public hearing be held to consider this application. Requests for public hearings shall state with particularity the reasons for holding a public hearing.
Endangered Species: Preliminary determinations indicate that the described activity may affect an endangered or threatened species or its critical habitat. Consultation under Section 7 of the Endangered Species Act of 1973 (87 Stat. 844) will be initiated. A permit for the proposed activity will not be issued until the consultation process is completed.
Cultural Resources: An initial evaluation of the proposed project area indicates the described activity is not located on property registered or eligible for registration in the latest published version of the National Register of Historic Places. The permit area has been extensively modified by modern development that little likelihood exists for the proposed project to affect an undisturbed historic property or any other type of cultural resource.
This notice has been provided to the State Historic Preservation Office, interested Native American Indian tribes, and other interested parties. If you have information pertaining to cultural resources within the permit area, please provide this information to the Corps’ project manager (identified above in this notice) to assist in a complete evaluation of potential effects.
Evaluation: The decision whether to issue a permit will be based on an evaluation of the probable impact including cumulative impacts of the described activity on the public interest. That decision will reflect the national concern for both protection and utilization of important resources. The benefit, which reasonably may be expected to accrue from the described activity, must be balanced against its reasonably foreseeable detriments. All factors, which may be relevant to the described activity will be considered including the cumulative effects thereof; among those are conservation, economics, aesthetics, general environmental concerns, wetlands, historic properties, fish and wildlife values, flood hazards, floodplain values, land use, navigation, shoreline erosion and accretion, recreation, water supply and conservation, water quality, energy needs, safety, food and fiber production, mineral needs, consideration of property ownership and, in general, the needs and welfare of the people.
The Corps is soliciting comments from the public; Federal, state, and local agencies and officials; Indian tribes; and other interested parties in order to consider and evaluate the impacts of this proposed activity. Any comments received will be considered by the Corps to determine whether to issue, modify, condition or deny a permit for this proposal. To make this decision, comments are used to assess impacts on endangered species, historic properties, water quality, general environmental effects, and the other public interest factors listed above. Comments are used in the preparation of an Environmental Assessment and/or an Environmental Impact Statement pursuant to the National Environmental Policy Act. Comments are also used to determine the need for a public hearing and to determine the overall public interest of the proposed activity.
Additional Requirements: State law requires that leases, easements, or permits be obtained for certain works or activity in the described waters. These state requirements must be met where applicable, and a Department of the Army permit must be obtained before any work within the applicable Statutory Authority previously indicated may be accomplished. Other local governmental agencies may also have ordinances or requirements, which must be satisfied before the work is accomplished.
Joint Removal-Fill Permit Application: Double H, LLC: 1455 Westec Drive, TM!L 1704333200201, Eugene, OR
l,
January 2013
3C.5
ll , - - - -
,,
-·.- '-~~--.
Gravel~
. Pit .
-,
.
('
J~m·z~·j -n~~~ ~.r?w·,~~LU~,
I
~
~ ::
~,
L~
T··,:i!l_,
P~:t-
\i
I,
'-·-~-~~---~
~
v
T"'"',,
'I
",,
"
II
II
II
II
II
!I
'·'
,,rl
II
II
if=~~
-~
1
i
-~-
RANDY PAPE BELTUNE
FIGURE 1: Site Location Map
5
Source: Eugene West USGS Quad
Scale: 2.6" = 1 mile
Page 1 of6
ENCL
Joint Removal-Fill Permit Application: Double H, LLC: 1455 Westec Drive, TM!L 1704333200201, Eugene, OR
N.W.1/4 S.W.1/4 SEC.33, T.17S. R.4 W.W.M.
LANE COUNTY
January 2013
17 04 33 32
EUGENE
SEE MAP 17 04 33 2
CANCELLED
600
602
201
4.40 AC.
LINE TABLE
"'
"'"'....
0
Q_
<
:::;
w
bl
CURVE TABLE
«
u>t'IE.·'-'
R~2!1D.IlU'
~
23'03'59'
t. ~6'lJTfl7'
"
LC·l56.1l.'
N23'tll'S9'(
P~l'Oo.oo·
A 16"113'07'
LC=lln40'
~~~1!0000'
LC·106.9Cl'
R·ZtiOJ.\0·
:
73'"':i£'lll'
l
"
~ ;~:~;:.· E
·4~7'35'
LC">l4B':I'
N
R~o;ooo·
!!li!7ll'OO'OO'
LC·ll1.66'
N 29"ll~3&· £
A 3i"'S'16'
R·
:
73~£.'111'
'
v
32 ..... 2':n'
LC·l-'2-937·
73·2S'Il0'E
t:.:h""OO'tl(l·
R·230.00'
'
r.~naw·
;
LC·\26.%'
R·
l.l32'112'l'i'
L0:"9!H16'
LC~73'
500
LBO AC
73'2~'00'
11'00'00'
'
N13":S6't6' v
11·7000'
'
LC·!102Y
R·90.00·
"'
l1'16'~·
v
7:1'31'2!'
N 37"18'06'
7'5"31'~1'
'
LC~t~72S'
NH"''7'l!i'
t.90"0J'v
LC·I27.e8'
R·'1000'
!;~:g_,~·
v
LC:tl2~'
N22'1l3':111:17000'
I> .,'ll:I'Ol"
'
A
N
FIGURE 2: Site Location on Tax Map
Tax map 17043332, Tax lot 00201
Source: Lane County Tax Map
Scale: Undetermined
Corps No. NWP-1995-1040/1
Page 2 of6
ENCL
Joint Removal-Fill Permit Application: Double H, LLC: 1455 Westec Drive, TM/L 1704333200201, Eugene, OR
January 2013
West 11th Avenue
I
j(-·-·-·
'r-- ·-
PROPOSED BUilDING
II II
II II
Ditch: 0.03 ac
Riverine Flow-through _ __,
HGMclass
W2:0.002ac
Depressional -ft-t~~>o~
HGMclass
A
N
0
20
40
W1:2.28ac
Slope/Flats
HGMdass
80
SCALE: 1"= 80'
LEGEND
Tax Lot Boundary
'------'1
\
\O
Wetlands
Wetland Impacts:
2.280 ac Removal in wetlands
2.312 ac Fill in wetlands/waters
\
All wetlands in PEM Cowardin class
__ ..l.._
Staging areas will be in previously
//,......
........,
disturbed areas/uplands at least 1 /
150 feet from adjacent wetlands /
and waterways
(
---
I
I
Ia;
\
\
\
\
\
·-·-·-· Existing ditch
PROPOSED
PROPOSED
BUILDING
I~
I~
I §
I~
I
' ~------~-......... --iI
\
\
\
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
FIGURE 9: Conceptual Site Plan
ENCL
Joint Removal-Fill Permit Application: Double H, LLC: 1455 Westec Drive, TMIL 1704333200201, Eugene, OR
January 2013
SCALE: 1"= 80'
LEGEND
- - - - Tax Lot Boundary
Existing Contours
···········392······· .. ·· Proposed Grading
o-~~---o Cross Sections
(See Figure 12)
-·~·-·-·-· Existing Ditch
L __ __ _ j
Wetlands
FIGURE 11: Existing Contours and Proposed Grading Plan
Joint Removal-Fill Permit Application: Double H, LLC: 1455 Westec Drive, TM/L 1704333200201, Eugene, OR
~PROPERTY LINE
PROPERTY LINE~
.....
I
I
I
I.
I
410
400
·L.. !...,,;;,r
·
T
390
I
I
380
I
I
0+50
1+00
·!
WETLAND
I
I
I
I.
I
sT sT
January 2013
I
I
I
I.
I
I
I
I.
I
-~-2J_27_2').J
I
I
I
I
!·
:-:\-:"\I.t:s"'-,-3-,-,_~
s-r 'S -r S)- S-\-::-~ - -5 ~ ~ - ..! ~ . -
1+50
2+00
2+50
3+00
3+50
4+00
4+50
5+00
5+50
6+00
6+50
7+00
SECTION A-A
/i PROPERTY LINE
410
400
I
jlllll
I
I
I
I
I
I
I
I
PROPERTY LINE~
WETLAND------t~~
1
I
I
I
I
I
I
I
390
380
0+50
1+00
1+50
2+00
2+50
3+00
3+50
4+00
4+50
5+00
5+50
6+00
6+50
7+00
SECTION B-B
t~ROPERTY LINE
410
I
I
I
I
.I
I
I
I
I
I
I
.
I
I
I
PROPERTY LINE~·
WETLAND-------II~:
I
I
I
I
I
I
I.
I.
I
......J
·rT..2 LL1-L:.J_L}_J .
-- -\Y\YS-.l:'.-..P-r..:t-· -I
1
r-r>Y}T2T3.A"Y'5TSYS S) c \ -s)
·- j
j
400
390
380
0+50
I
1+00
1+50
2+00
2+50
3+00
3+50
4+00
4+50
I
5+00
5+50
6+00
6+50
SECTION C-C
LEGEND
SCALE
- - - Existing contours
--------Proposed grading
Horizontal: 1"= 80'
Vertical: 1"= 20'
VI I I I I Removal
I\\\\ \1 Fill
···wetlands
FIGURE 12: Existing and Proposed Cross Sections
See Figure 11 for cross section locations
0
-,.T
-,.THTT\1f'\f'\~1AA'1
.L
"-5'-'
..J U.l U
f5Jint Removal-Fill Permit Application: Double H, LLC: 1455 Westec Drive, TM!L 1704333200201, Eugene, OR
January 2013
,_
LEGEND
FOUND MONUMENT
EXISTING GAS VALVE
BOUNDARY
EXISTING GAS METER
ADJACENTPROPERTl'LINE
EXISTING ElfCTRtcAL VAULT
EXISTING CURB & GUTIER
TREES SPN:ED
~
SCAlE
,·,w·
fO'
80'
EXISTING UNDER GROUND ELECTRICAL WlE
UGE
POCK CHECK OAMS 0 12'
-··-··-
WETL..AND BOUNDARY
EXISTING STREET UGHT
PROPOSED DRAINAGE BASIN
EXISTING JUNCTION BOX
EXISTING ROAD SIGN
a·w
e'!W
YIW
EXISTING WATER LINE
"
PHN
EXtSTING WASTEWATER MANHOLE & PIPE
EXISTING CATCH BASIN
EXISTING FIRE HYDRANT
D
EXISTING WATER VALVE
E~ISTING
IN!!RVALS OR MIHIIAUU 2. DAMS
PERS'oi.'ALE
PROPOSED CATCH BASIN
EXISTING CURB INLG
24"ST
PHONE LINE
ST
-..,'-MINIMUM1:Z"GROWIM:i
MEDIUM
EXISTlNG STORM DRAJNAGE SYSTEM
3"ROIJNOROCK
EXISTING PHONE PEDESTAL
11)---01--1)
EXISTING GAS LINE
RD
PROPOSED STORIII DRAINAGE SYSTEM
ROOF ORiiJN
UUfFAll smuCTUP.E
GRASSY S11ALE CROSS SECTION
CHECK DAM DETAIL
NfS
NTS
I,
NOTES:
1. POLLUTION CONTROL DEVICE SHALL BE AQUA-SHIELD ADUA-S\IllRL OR AN
AlTERNATE DEVICE SIZED APPROPRlii.TELY AND LISTED ON 111£ CITY or EUGENE
"APPROVED PROPRIITARY STORMWATER TREAT1.1ENT TECHNOLOGIES'
17-04-33-ZO
T.L. 603
E~
STORM WArER SKErr _.}·/
ORAINSNORTH.4Cii'OSS
LL 60j TO 11-iE
~MAlON
CH.\fJNEL
A= 113,066 SQ. FT.
LOT 6
1\'RSTBC BUSlNESS PARK
B "' 44,235
so.
FT.
C = 7,652 SO. FT.
D , 9,388 SO. FT
FIGURE 13: Post-Construction Site Drainage Plan