You can copy from here when filling out the rest of the page.
APPLICANT/IN-LIEU FEE SPONSOR: Missouri Conservation Heritage Foundation
PROJECT LOCATION: The proposed mitigation plan No. SSTF1004-Dallas County is located along Hays Road at an existing crossing in Greasy Creek in the northeast quarter of Section 6, Township 33 north, Range 19 west, Dallas County, Missouri.
ACTIVITY: The Missouri Conservation Heritage Foundation proposes under its Stream Stewardship Trust Fund (SSTF) In-Lieu Fee Instrument to establish mitigation plan No. SSTF1004-Dallas County entitled the Hayes Road Low Water Crossing Replacement Project.
APPLICANT/IN-LIEU FEE SPONSOR: Missouri Conservation Heritage Foundation
PROJECT LOCATION: The proposed mitigation plan No. SSTF1004-Dallas County is located along Hays Road at an existing crossing inGreasy Creek in the northeast quarter of Section 6, Township 33 north, Range 19 west, Dallas County, Missouri.
ACTIVITY: The Missouri Conservation Heritage Foundation proposes under its Stream Stewardship Trust Fund (SSTF) In-Lieu Fee Instrument to establish mitigation plan No. SSTF1004-Dallas County entitled the Hayes Road Low Water Crossing Replacement Project.
MISSOURI CONSERVATION HERITAGE FOUNDATION
STREAM STEWARDSHIP TRUST FUND GRANT PROGRAM
REQUEST FOR MITIGATION PLAN APPROVAL
The Stream Stewardship Trust Fund is available to restore, enhance, and/or protect stream systems and
associated riparian habitats. Proposed projects will be prioritized and funded by the Foundation based on regional
stream needs, maximum return on expended monies, level of threat to the stream system, and overall anticipated
benefits to stream resources. Proposed projects should be located within the ecological drainage unit (EDU) where
participating stream impacts occurred. Approval will be limited to projects that restore, enhance, or preserve
Missouri's diverse stream systems.
This request form will be used by MCHF Board members assigned to the Stream Stewardship Trust Fund Grant
Program Action Team. Proposals submitted for funding consideration need to clearly explain elements of streambased projects listed below which warrant consideration during the approval process. Spaces provided in the
elements below are not to be considered limiting, and the attachment of additional pages of explanation is
encouraged in order to provide full details.
The Goal of the MCHF's Stream Stewardship Trust Fund is to provide an innovative tool for the
restoration, enhancement, and protection of Missouri's streams and aquatic resources.
1) Project Title
Hayes Road Low Water Crossing Replacement Project, Greasy Creek
Landowner Name
2) County
3)
Dallas
Dallas County Commission
MDC region
Southwest
Project objectives We are proposing this project because we believe it will fulfill the following
objectives. One objective of the project is to replace the existing low water crossing with a newly
designed, clear-span low water crossing to facilitate fish passage and allow for improved
sediment transport increasing stream stability. A second objective is to use the newly designed
crossing as a demonstration project for neighboring county road services working on streams
within the Niangua darter range. A third objective is for Missouri Department of Conservation
(MDC) personnel to monitor and evaluate changes in Niangua darter populations and their
subsequent distribution. These objectives will all address specific areas of concern discussed in
the Compensation Planning framework for the Ozark/Osage EDU including aquatic resource
problems, water quality problems, and aquatic resource conditions. The portions of the Niangua
River near Benton Branch (Williams Ford) will be used as a reference reach to help establish
achievement of the defined objectives.
4) The project submitted for consideration is in the Niangua River watershed and is considered a
priority by MDC for the following reasons (include how project achieves watershed objectives
and describe the rationale for site selection). Greasy Creek, a major tributary to the Niangua
River, contains 12.9 miles of Niangua darter known range. The Niangua River watershed contains
a total of 62.6 miles of Niangua darter known range, of which 31 miles are federally designated
critical habitat. Replacing the existing low water crossing with a clear-span structure will not
only facilitate fish passage, but will also improve sediment transport thereby restoring a critical
component of the natural stream process and enhancing stream habitat stability within this reach
of habitat. An inventory and assessment of low water crossings, including a priority ranking
report, has been completed for the entire range of the Niangua darter. The inventory data has been
entered into the National Fish Passage Decision Support System and can be found with the online GeoFIN application (http://ecos.fws.gov/geofin/). There were five crossings originally
identified as fish passage barriers in the Niangua River watershed (three on the Niangua River
and two on Greasy Creek). Two of those, both on the Niangua River, have been replaced with
passage friendly structures. A third, also on the Niangua River, is currently in the process of
being replaced. This project would be consistent with four goals that are identified as Fiscal Year
2014 Department Priorities by Goal: 1) Healthy forests, fish and wildlife. Ensure healthy and
sustainable forest, fish and wildlife resources throughout the state; 2) Sound business and
workplace practices. Ensure sound financial accountability and transparency in all areas of
operation; 3) Citizen involvement/education. Provide opportunities for active citizen
involvement in services and conservation education in both rural and urban areas; and 4) Engage
partners. Engage partners at all levels (individual, community, county, state, federal) to enhance
natural resources and effective delivery of conservation service. Additionally, this project would
be consistent with a MDC's Fisheries Division stretch goal: Fish Habitat Enhancement...enhance
aquatic organism passage on selected streams by involving a variety of partners and using a mix
of internal and external funding.
5) Site protection instrument (circle):
Acquisition
Perpetual easement
Special management agreement
6) Describe the details of the site protection instrument (ownership, legal arrangements, how the
instrument assures the long term protection of the proposed mitigation site):
This project
will be completed under a 30-year term cooperative agreement between Dallas County and the
Missouri Department of Conservation; a standard agreement used to implement projects within
the Niangua Darter Habitat Enhancement Low Water Crossing Assistance Program.
7)
Baseline information
a. Describe the ecological characteristics of the proposed project site: The project site is
located on Greasy Creek approximately 4.9 river miles upstream from its confluence with
the Niangua River. Greasy Creek is a 4th order stream with a 46,228 acre watersehd.
This site is also located about in the center of the 12.9 miles of Niangua Darter known
range within Greasy Creek.
b. Historic and existing plant communities, hydrology and soils of the proposed project site:
Land cover in the Greasy Creek watershed before settlement was a mosaic of prairie,
savanna, and forest. The undissected uplands were dominated by patches of prairie and
savanna with high grasses and large post oaks. Areas of greater relief and narrow
ridgetops were dominated by oak-hickory forest with occasional patches of prairie in the
bottomland. Currently much of the land within the watershed has been converted from
forest, savanna and prairie to cattle pasture and hay-land. Overall, the Niangua River
Watershed lies in the Salem Plateau subdivision of the Ozark Plateau physiographic
region. The watershed is underlain with several hundred feet of Ordovician and
Cambrian rock, largely dolomite. The edges of the watershed lie in Jefferson City-Cotter
dolomite, while streams cut into progressively older Roubidoux, Gasconade, and
Eminence formations. There is considerable subsurface movement of water in the
watershed through solution dissolved channels in the fractured and jointed dolomite. As a
result, karst features such as caves, sinkholes, losing streams, and springs are abundant.
Streams which incise into the middle or lower Gasconade have well sustained base flows
even during dry periods, due to ample groundwater supplies. Streams which incise into
the Roubidoux formation are frequently losing streams and sinkholes are common. Soils
in the watershed are classified as residual, alluvial, colluvial, and loess. Residual soils
consist primarily of material weathered from cherty dolomite, dolomite, and sandstone,
and occur on the surface of steep slopes. When they develop in uplands from Roubidoux
formations, and Jefferson City - Cotter dolomites, an impervious fragipan usually occurs
18 to 24 inches below the surface. Colluvial soils, which are soils deposited on lower
valley slopes by erosion from more elevated sites, are limited in abundance. Alluvial soils
are those transported by streams and deposited on level or gently sloping areas in flood
plains. They range in size from silt to gravel. Loess soils are silty, windblown material
which commonly occur on ridgetops.
c. Project application must include maps identifying the proposed project boundary with
lat/long boundaries in decimal degrees and a GIS shape file with metadata of the
delineated boundary. See attached figures for project location and details.
d. Describe existing hydro-system connectivity between the stream project site and any
wetlands or other waters including tributaries connecting to receiving waters:
The project site is located on Greasy Creek approximately 4.9 river miles upstream from
its confluence with the Niangua River. The project site is located about mid-way in the
12.9 miles of Niangua Darter known range on Greasy Creek. Greasy Creek enters the
Niangua River within the 31.0 miles stretch of federally designated critical habitat; 12.5
miles upstream from the downstream boundary. In addition to federally designated
critical habitat, the Niangua River contains 47.1 miles of known range. A total of
approximately 9.0 miles of known range within Greasy Creek will be opened above this
project site. When modeling this site with the GeoFIN web-based application, a total of
183.9 miles (295.9 km) of streams within the Greasy Creek watershed upstream from this
barrier are opened.
8) Determination of credits as determined by the Missouri Mitigation Method (attach credit
calculation worksheet or other detailed information to demonstrate the specific approach for
credit calculation for this project):
a. Number of stream channel credits 11,500
b. Number of riparian credits N/A
c. Stream type (circle): Ephemeral
Intermittent
Perennial
Credit release schedule:
20%
Upon project approval by the COE and IRT
20%
Upon completion of the project and signing of long term maintenance agreement.
60%
After two bank-full flow events or a maximum of two years, whichever occurs first.
Our experience and observations suggest that the stability of the structure and its effects on the
stream channel and related habitat could easily be observed after two high flow events and those
events would be likely to occur, on average, within or prior to a two year time frame.
9) Mitigation work plan
a. Specifications of the project (geographic boundaries, construction methods, timing,
sequence): The current low water crossing is a typical vented ford with three concrete
box culverts. Aquatic organism passage barriers exist (particularly to benthic fishes) at
low flows due to the culverts being perched above the stream bed, as well as a biological
barrier due to the concrete floor and walls. At moderate to high flows, the structure
creates velocity, exhaustion, and jump barriers. The boundaries of the project will be
confined to the foot-print of the existing low water crossing. The project will entail
demolition of the existing low water crossing by chipping/breaking up of the structure,
then loading and hauling the refuge off site. Once removed, the new low water bridge
(clear-span design) will be constructed on the same foot-print and tie into the existing
road approaches. Design plans have yet to be developed, but, will be similar to recently
completed single clear-span crossings used in numerous other low water crossing
replacement projects throughout Niangua Darter range as part of this recovery effort to
address AOP concerns. It is anticipated that all in-stream work related to this project will
be completed soon after the seasonal spawning time frame (March 15 through June 15)
2015. The demolition/construction portion of this project should take approximately 60
working days.
b. Methods for establishing desired plant community (species composition and type, control
of undesirable species, size of plants used, control of wildlife damage): This project
does not include establishing any plant communities. Any areas disturbed during
construction will be planted to pre-existing cover.
c. Grading plan and elevations of constructed features (describe or attach engineering
design plans):Although design plans have not been completed for this project, the
elevation of the new low water bridge will not be significantly higher than the existing
low water crossing. Since the existing road approaches will be used the grade of the new
structure will closely match that of the existing structure. However, the new structure
will be a clear-span type of structure without a floor and will utilize the natural stream
bed to facilitate AOP and natural sediment transport. Actual design will take place after
project approval.
d. Describe or attach drawings showing existing stream channel cross sections, proposed
alterations to the stream channel and/or banks, a description of in-stream structures
including materials used for improvements, dimensions and elevations, and riparian
plantings: No alterations to the existing stream channel and/or banks are planned for this
project. A low water bridge, clear-span type of structure will be constructed in place of
the existing vented ford low water crossing. Some rip-rap will be placed around the
bridge abutments to protect from scour. The new low water bridge will have a clear-span
approximately 45 feet long with an elevation similar to the existing low water crossing.
10) Maintenance plan:
a. Description and schedule of maintenance following initial construction: As outlined in
the cooperative agreement, the county agrees to: 1) remove gravel and flood debris from
the deck of the crossing as needed; 2) remove snags and obstructions from the stream
channel, in the immediate vicinity of the crossing, if flow under the crossing is
obstructed; 3) examine the crossing immediately following high flow events for scour or
undercutting that may impact the structural integrity of the crossing; and 4) provide
maintenance as needed to the crossing and roadway approaches.
b. Mowing frequency and timing: Not applicable.
c. Herbicide applications (chemical used, method, timing, frequency): Not applicable.
d. Irrigation plan (include source of water): Not applicable.
e. Passive water control and instream structure description and required maintenance (type
and frequency): See item (a) for maintenance information.
11) Performance standards
a. Description of the performance standards used (include metrics for determining project
success):
Riparian: Not applicable.
Stream Channel: The three main standards that will be met by this project are: 1) the
existing crossing that has been identified as a barrier to AOP and sediment transport will
be removed; 2) the newly designed clear-span low water bridge will not have a floor and
use the natural stream bed; and 3) the length of the clear-span low water bridge will be
greater than 75% of the bank-full channel width.
Reference stream(s) used (if any): These performance standards have been documented
in being successful in facilitating AOP and sediment transport in the connecting Niangua
River and nearby Little Niangua River consistent with this recovery effort throughout
Niangua Darter range.
b.
Describe how the performance standards relate to the objectives of the mitigation site
(include description of the desired resource type, expected functions or services being
measured, or any other applicable metrics): Replacing the existing low water crossing
with a clear-span structure will not only facilitate fish passage, but will also improve
sediment transport thereby restoring a critical component of the natural stream process
and enhancing stream habitat stability within this reach of habitat. The portions of the
Niangua River near Benton Branch (Williams Ford) will be used as a reference reach to
help establish achievement of defined objectives.
12) Describe the method and frequency of project monitoring to determine when performance
standards are being met (project site must be monitored for an appropriate period not less than 5
years after initial construction/planting), who will be conducting the monitoring, and the
frequency monitoring reports will be submitted: Numerous low water crossings on streams
within the range of the Niangua Darter Etheostoma nianguae are barriers to the passage of
aquatic organisms, materials, and degrade habitat for small, benthic fishes. Ongoing cooperative
efforts between the Missouri Department of Conservation and several partners (US Fish &
Wildlife Service, Missouri Conservation Heritage Foundation, Missouri Department of
Transportation, Federal Emergency Management Agency, county governments) have allowed for
prioritization and subsequent replacement of many poorly-designed crossings with clear-span
bridges. Goals of the projects include improving fish passage and restoring habitat while at the
same time reducing the need for maintenance and increasing the availability and safety of the
crossing for use by road traffic. We provide monitoring to evaluate the response of Niangua
Darter populations and habitat associated with low water crossing improvement projects. Study
sites extend approximately 300 m upstream and downstream from each crossing. We categorized
and sampled all non-deep pool habitat patches within the site boundaries including riffles, runs,
glides, shallow pools, and pool edges. Pool edges are identified by a somewhat gentle slope of
predominately clean gravel, often with water willow (Justicia sp.), bordering one or sometimes
both sides of a deep pool. With the exception of some edges, deep pools are not sampled. At the
downstream boundary of each habitat patch, we measure lateral secchi disk visibility and water
temperature. Fish sampling is performed by two snorkelers moving upstream through each
longitudinal half of a habitat patch in a zigzag pattern at a rate of 3 m/min. In very shallow areas
(<10 cm), counts are conducted by slowly walking and visually scanning the stream bottom with
the aid of polarized sunglasses. When a Niangua Darter is sighted, investigators identified it as a
juvenile or adult. Juveniles, spawned during April or May, are markedly smaller at the time
sampling is performed in June and unlikely to have exceed 40 mm in total length. We use
multiple-pass, depletion/removal methods to estimate Niangua Darter population metrics for each
habitat patch where more than one Niangua Darter is discovered. When an adult-sized Niangua
Darter is sighted, the snorkelers capture it by surrounding the fish with four aquarium nets.
Niangua Darters collected during this first pass through the habitat patch are placed in a floating
net bag (3.2 mm mesh). Juvenile Niangua Darters are counted but not included in population
estimates because of the high variability associated with their abundance, difficulties in surveying
the shallow habitats where they occur, and concerns related to the potential for injury from
handling. After the habitat patch had been searched, snorkelers perform additional passes
according to the following guidelines:
a. Stop after 1 pass if # adult Niangua Darters = 0 or 1
b. Stop after 2 passes if
i. pass 2 # adult Niangua Darters = 0
ii. pass 1 + pass2 # Niangua Darters 3
iii. depletion from pass 1 to 2 > 80%
c. If time is limited stop after 3 passes if no single pass # Niangua Darters > 3
The guidelines are selected to accelerate progress through habitat patches where Niangua Darters
are sparse and sample size would be too low for meaningful population estimates. During each
pass, snorkelers employ a comparable degree of effort by thoroughly searching the same locations
within the habitat patch. Juvenile Niangua Darters are ignored after the first pass to avoid
double-counting. Additional net bags are used as necessary to reduce risks associated with
overcrowding and for counting fish from different passes. After sampling of a habitat patch is
completed, Niangua Darters are returned to locations with cover and distributed among original
collection points at densities approximating those observed during sampling. We record the
presence of all darter species observed by snorkelers as they search a habitat patch. We also
measure the length of each habitat patch and at three equally-spaced points at mid-channel
measure wetted width, depth, mean column water velocity, and dominant substrate type using a
modified Wentworth classification of particle diameter including fines (< 2 mm), gravel (2 - 15
mm), pebble (16 - 63 mm), cobble (64 - 256 mm), boulder (> 256 mm), and bedrock.
Measurements of length and width are made to the nearest 1-m with a laser rangefinder or visual
estimation for distances < 10 m. Depths are measured to the nearest 1-cm and velocities to the
nearest 1-cm/s using a calibrated wading staff and Marsh McBirney Flo-Mate 2000 current
velocity meter. We also classify the percentage length of each habitat patch bordered on either
side by wetted water willow, dense algal blooms, bank erosion (e.g., lack of attached vegetation
and with eroding base), livestock use, and other significant disturbances such as gravel removal.
Habitat percentage classes included 0-5%, 6-25%, 26-50%, 51-75%, 76-100%. After we
complete sampling of fish and habitat patches, we performed a Wolman pebble count to ascertain
patterns in the sizes of rocky substrates and also estimated the embeddedness of the rocky
substrate matrix by fine sediments. Both measurements are relevant to determining habitat
suitability for small, benthic fishes that forage, find shelter, and reproduce dependent on
characteristics of the interstitial spaces in the stream bottom. The pebble count is performed by
measuring the intermediate axis (nearest 1-mm) of the particle encountered at toe-point as we
walk transects crossing the stream channel diagonally from one high-water bank to the other.
Each transect crosses a 50-m length of stream and particles are selected with a frequency that
result in approximately 20 measurements per transect. At each point where a particle is
measured, we also estimate if larger rocky particles are surrounded or covered by fine sediment to
a degree < or > 75% (highly embedded). We used the Zippin M(b) model and Program
CAPTURE2 v.090210.1141 to obtain estimates for population size, precision, and capture
probability for adult Niangua Darters. The model assumption of closure is satisfied because
Niangua Darter movements are limited, movement among habitat patches is often discouraged by
natural barriers (high flow, excessive depth, lack of cover, unsuitable substrate), and our sampling
method is of short duration and minimally intrusive to avoid driving darters ahead of snorkelers.
We evaluate changes in Niangua Darter populations, darter species richness, and habitat by
inspecting data summaries for pre- and post-replacement time periods in the reaches upstream
and downstream of each crossing. Particle diameter measurements derived from pebble counts
are summarized for each transect and cumulative relative frequency plots created for pre- and
post-replacement time periods. For most crossings it is only possible to collect a single prereplacement sample, therefore we compared pre-replacement values with the summarized postreplacement values and consider the degree of overlap given the amount of variation and
direction of change. Post-replacement sampling occurs during each of the first three years after
construction of a new bridge. A three-year hiatus from sampling follows the first postreplacement time period, then a second three-year sampling period is initiated. For example, the
crossing will be sampled during years 1-3 and years 7-9 following replacement. Doug Novinger
of the Missouri Department of Conservation, Resource Science Division will be leading the low
water crossing Niangua Darter monitoring efforts. Craig Fuller of the Missouri Department of
Conservation, Fisheries Division will be collecting standardized photo-monitoring information.
13) Long-term management plan:
a. Describe how the project site will be managed after performance standards have been
met: Through the 30-year term cooperative agreement the county has agreed to provide
standard maintenance as outlined above. Additionally, through the cooperative
agreement the county has agreed to incorporate fish passage and sediment transport
considerations into subsequent design and construction whenever the crossing must be
repaired or replaced.
b. Annual cost estimate for management: $ Responsibility of Dallas County
c. Funding mechanisms will be used to finance long term management (including
responsible party: Dallas County road and bridge department will manage and perform
maintenance as needed. Funding will be provided through the counties annual budget for
road/bridge maintenance.
d. Long term management responsibilities transferred to (include description of their long
term management plan and a written stewardship commitment that includes a financing
plan): Long term management responsibilities are transferred to Dallas County
Commission. A long term management plan and stewardship commitment are included
in the above referenced cooperative agreement.
14) Adaptive management plan (due to inability to construct project in accordance with approved
plans, monitoring revealing that the project is not meeting performance standards, remedial
measures resulting in project modifications, design changes, revisions to maintenance
requirements, revised monitoring, etc):
a. Description of strategy to address unforeseen changes in the project: If there is an
inability to construct the project in accordance with approved plans, no further action will
be taken and the existing structure will be left in place. If the structure fails due to an act
of God, the County has agreed to replace the structure with a new structure that facilitates
fish passage and sediment transport. Design changes will only occur after consultation
and approval by MDC, USFWS, USACOE, and County.
b. Party (ies) responsible for implementing adaptive management: If failure in the project is
due to an act of God, the agencies will assist with adaptive management implementation.
If project failure is due to County negligence, the County will be responsible for
implementing adaptive management plans and remedial measures with oversight from
agencies.
15) Financial Assurances:
The MCHF has previously demonstrated its ability to fund good stream projects and is committed
to the installation, monitoring, and long term management of its compensatory mitigation
projects. Since an important basis for project selection is a project's fit into MDC's statewide
stream management plan, a commitment of the biological, engineering, and legal resources of
MDC also accompanies each project. In addition to MDC's support, the MCHF has incorporated
financial assurances into its cost-per-credit and will retain financial assurances not to exceed 10%
of each project's estimated completion cost to establish a continuous contingency fund balance of
$250,000.00.
16) Total cost of the project is estimated at $ 197,000. SSTF Resources are requested in the amount
of $ 100,000.
17) Partner funds in the amount of $ 97,000 are being contributed by: (if applicable): US Fish and
Wildlife Service ($62,000); Dallas County Commission ($25,000); MDC ($10,000 in-kind
services).
18) Total stream length of the project
NA
Total Riparian corridor acreage NA
19) Total cost per credit (including all costs) estimated at $ 16.66
.
20) If the project is leveraged with contributions from others, SSTF Resources are requested to fund
which practices/products/costs activities? Project engineering/design; and, demolition, hauling
and disposal of existing low water crossing.
21) Schedule for project completion and/or installation: Planning, engineering, environmental review
and permit acquisition Winter 2014 and Spring 2015. Demolition, removal of existing crossing
and construction of new crossing summer 2015.
Note: Proposal must include appropriate on-site photographs, county maps locating the proposed
project, related topographic, soils, or other maps, drawings and materials necessary to describe
planned activities. In order to reproduce color photographs and maps, a complete electronic file
is requested with project proposals.
Attachment- Map of the State, Highlighting Location of the Watershed
Attachment- Watershed Map with location of project site in relation to other project sites, Niangua
Darter federally designated critical habitat and Niangua Darter known range.
Attachment- Aerial photo and topographic map of Dallas County Hayes Road/Greasy Creek
project site with GPS coordinates and associated shapefile name.
Attachment- Pictures of the Project Site
Looking at upstream side of crossing
Looking at downstream side of crossing
Looking upstream from crossing
Looking downstream from crossing
Attachment- Example of the proposed clear-span (45-foot) low water bridge design to be used on
Dallas County Hayes Road over Greasy Creek.
Photo of the completed 45-foot clear-span low water bridge located on Dallas County School Road over
the Little Niangua River as part of the Niangua Darter (AOP) recovery efforts.
-0
"
"
-6
"
1'
-0
"
2'
'-0
"1
-0
1'
"
-6
1'
5'
"
'-0
17
CL ROADWAY
2'-6 1/2"±
"
12
"
5'-0"
45°
'-1
0
#6F W13A BARS
@ 11" O.C.
12
"
"
'-0
17
18
1'-6"
1'-6"
FOOTING
1'
0"
-1
10"
12'-7"
10"
12'-7"
FILL FACE
STREAM FACE
PLAN VIEW OF GEOMETRY
2'-0"
U11A BARS
** FILL AREA UNDER GIRDER WITH JOINT FILLER TO BE
SUPPLIED BY CONTRACTOR. JOINT FILLER MUST BE IN
PLACE PRIOR TO SETTING BEAMS.
FW13A BARS
V BARS
#6 FW12A BARS
@ 11" O.C.
T11A BARS
1'-9"
LAP
FW
EQ 1
. S 1A
PA BA
C RS
ED
H11A BARS
A
*** T12A BARS
D11A, D13A, D15A, D17A,
D19A & D21A BARS
FW12A BARS
(6) #6 FW14A BARS
(1/2 TOP & BOT.)
FW13A BARS
B
D12A, D14A, D16A, D18A,
D20A & D22A BARS
H11A BARS
U11A BARS
V11A BARS
SECTION B-B
ABUTMENT REINFORCEMENT
FW14A BARS
EQ. SPACED
V12A BARS
135
°
5"
T12A BENDING
DIAGRAM
FW12A BARS
B
V13A BARS
PLAN VIEW OF REBAR
*** T12A BARS SHALL BE FIELD BENT TO FIT THE WING
WALL ELBOW.
°
135
5"
S1-S7_DE
NTS
NOTE:
THIS DRAWING NOT TO SCALE. FOLLOW DIMENSIONS.
T12A BENDING
DIAGRAM
01.22.2013
CL ROADWAY
17'-0"
1'-10"
10"
12'-7"
10"
12'-7"
1"
1'-10"
17'-0"
1"
EL 896.00
SLOPE 2%
SLOPE 2%
EL 895.75
EL 895.75
EL 894.04
EL 893.79
1'-3"
EL 893.79
ELEVATION OF STREAM FACE GEOMETRY
(WINGWALLS SHOWN STRAIGHT FOR CLARITY)
CL ROADWAY
17'-0"
12"
12'-7"
12"
1"
17'-0"
1"
EL 896.00
SLOPE 2%
SLOPE 2%
EL 895.75
EL 893.79
EL 895.75
EL 894.04
EL 893.79
TOP OF FOOTING
EL 887.75
BOTTOM OF FOOTING
EL 885.2±
ELEVATION OF FILL FACE GEOMETRY
(WINGWALLS SHOWN STRAIGHT FOR CLARITY)
S1-S7_DE
NTS
01.22.2013
NOTE:
THIS DRAWING NOT TO SCALE. FOLLOW DIMENSIONS.
SEE DETAIL A
(56) #7 V11A BARS (1/2 E.F.)
(28) #4 U11A BARS
(36) #7 V12A BARS (1/2 E.F.)
5 1/2"
17 SPACES @ 11"
12"
SEE DETAIL B
CL ROADWAY
13 SPCS @ 11"
5 1/2"
(36) #7 V12A BARS (1/2 E.F.)
13 SPCS @ 11"
17 SPACES @ 11"
(1) #6 D24A BAR
(1) #6 D24A BAR
EL 894.04
(5) #6 D14A, D16A,
D18A, D20A
& D22A BARS
12"
4 SPCS @ 12"
(1) #6 D12A BAR
7 3/4"
12"
(1) #6 D12A BAR
(1) #4 T12A BARS
(STREAM FACE)
5 SPACES @ 12"
(12) #6 H11A BARS
(1/2 E.F.)
(1) #4 T12A BARS
(STREAM FACE)
12"
4 SPCS @ 12"
12"
EL 893.79
7 3/4"
(5) #6 D14A, D16A, D18A,
D20A & D22A BARS
EL 893.79
12"
STREAM FACE ELEVATION
(WINGWALLS SHOWN STRAIGHT FOR CLARITY)
2 1/2"
2 1/2"
(1) #6 D11A BAR
12"
7 3/4"
TOP OF FOOTING
EL 887.75
7 3/4"
12"
(1) #6 D11A BAR
BOTTOM OF FOOTING
EL 885.2±
65 SPACES @ 11"
1'-1 1/2"
10 1/2"
(132) #6 FW13A BARS (1/2 E.F.), (132) #6 FW12A BARS (1/2 TOP & BOTTOM), (132) #6 DOWELS (1/2 E.F.)
FILL FACE ELEVATION
(3) #7 V13A
BARS
5"
11"
(3) #7 V13A
BARS
(WINGWALLS SHOWN STRAIGHT FOR CLARITY)
6 1/2"
3 1/2"
6 1/2"
3 1/2"
2 1/2"
2 1/2"
EL 893.79
5"
11"
EL 893.79
S1-S7_DE
NTS
01.22.2013
NOTE:
THIS DRAWING NOT TO SCALE. FOLLOW DIMENSIONS.
DETAIL "A"
DETAIL "B"
5'-0"
2'-0"
1'-6"
1'-6"
"
17'-0"
17
'-0
12" 12"
** JOINT
FILLER (TYP.)
"
12
"
'-0
17
#6 FW23B BARS
@ 11" O.C.
BEARING PAD
25'-0" x 6" x 1/2"
1'-6"
90
5'-0"
2'-0"
°
0"
-1
1'
1'-6"
12" 12"
45°
0"
'-1
18
FILL FACE
10"
12'-7"
2'-0"
12'-7"
2'-0"
PLAN VIEW OF GEOMETRY
FILL FACE
STREAM FACE
2'-0"
** FILL AREA UNDER GIRDER WITH JOINT FILLER TO BE
SUPPLIED BY CONTRACTOR. JOINT FILLER MUST BE
IN PLACE PRIOR TO SETTING BEAMS.
U21B BARS
H21B BARS
V BARS
1'-9"
LAP
#6 FW22B BARS
@ 11" O.C.
FW22B BARS
(6) #6 FW24B BARS
(1/2 TOP & BOT.)
SECTION B-B
ABUTMENT REINFORCEMENT
PLAN VIEW OF FOOTING REBAR
S1-S7_DE
NTS
01.22.2013
NOTE:
THIS DRAWING NOT TO SCALE. FOLLOW DIMENSIONS.
17'-0"
1'-10"
10"
2'-0"
1"
2'-0"
1"
A
A
ELEVATION OF STREAM FACE GEOMETRY
(ONE WINGWALL SHOWN STRAIGHT FOR CLARITY)
17'-0"
15'-0"
2'-0"
B
2'-0"
ELEVATION A-A
ELEVATION OF WINGWALL STREAM FACE GEOMETRY
2'-0"
12"
1"
17'-0"
1"
EL 890.75
TOP OF
FOOTING
EL 887.80
BOTTOM OF
FOOTING
EL 885.30
B
ELEVATION B-B
ELEVATION OF WINGWALL FILL FACE GEOMETRY
ELEVATION OF FILL FACE GEOMETRY
(ONE WINGWALL SHOWN STRAIGHT FOR CLARITY)
S1-S7_DE
NTS
01.22.2013
NOTE:
THIS DRAWING NOT TO SCALE. FOLLOW DIMENSIONS.
(5) #7 V23B
BARS
2 1/2"
12 1/2"
3 1/2"
4 SPCS
@ ABT. 10 1/4"
(32) #7 V24B BARS (1/2 E.F.)
11"
15 SPACES @ 11"
12"
C
3" CLR.
D
3"
CLR.
10 3/4"
(7) #6 D32B BARS
(1) #6 D30B BAR
6 SPACES @ 12"
D
3 1/2"
3 1/2"
#6 FW21B BARS
#6 x 12" DOWELS, EVERY 5TH DOWEL
SHALL BE 3'-5" LONG, CONTRACTOR
SHALL VERIFY LOCATION WITH ENGINEER
#6 FW24B BARS
#6 FW22B BARS
#6 FW22B BARS
#6 FW25B BARS
STREAM FACE ELEVATION
C
(ONE WINGWALL SHOWN STRAIGHT FOR CLARITY)
#6 FW25B BARS
#6 FW22B BARS
ELEVATION C-C
ELEVATION OF WINGWALL STREAM FACE
V23B BARS
135
°
5"
SECTION D-D PLAN VIEW OF REBAR
T22B BENDING
DIAGRAM
S1-S7_DE
NTS
01.22.2013
NOTE:
THIS DRAWING NOT TO SCALE. FOLLOW DIMENSIONS.
SEE DETAIL C
2 1/2"
6"
T23B BARS
D31B BARS
(1) #4 T24B BARS
(FILL FACE)
12" 12"
V23B BARS
2 SPCS
@ 12" 12"
(1) #6 D29B BAR
D26B BARS
BOTTOM OF
FOOTING
EL 885.30
#6 FW22B BARS
#6 FW25B BARS
E
#6 FW22B BARS
5 SPACES @ 11"
#6 FW21B BARS
#6 x 12" DOWELS, EVERY 5TH DOWEL
SHALL BE 3'-5" LONG, CONTRACTOR
SHALL VERIFY LOCATION WITH ENGINEER
#6 FW24B BARS
(3) #6 D21B BARS
(FILL FACE)
TOP OF
FOOTING
EL 887.80
1'-2 1/2"
(3) #6 D23B, D25B,
& D27B BARS
E
1'-1 1/4"
46 SPACES @ 11"
(10) #6 DOWELS
(1/2 E.F.)
(94) #6 FW23B BARS (1/2 E.F.), (94) #6 FW22B BARS (1/2 TOP & BOTTOM), (94) #6 DOWELS (1/2 E.F.)
FILL FACE ELEVATION
(ONE WINGWALL SHOWN STRAIGHT FOR CLARITY)
(32) #7 V24B BARS (1/2 E.F.)
15 SPACES @ 11"
12"
3"
3" CLR.
(2) #4 T23B BARS
(FILL FACE)
D26B BARS
(3) #7 V23
BARS
(16) #6 D31B BARS
V23B BARS
5 SPACES @ 12"
D25B BARS
2 SPCS
@ 11"
1 1/2"
3" CLR.
#6 FW22B BARS
12"
10 3/4"
4 1/2" CLR.
T23 BARS
D31 BARS
#6 FW25B BARS
17 SPACES @ 11"
(36) #6 FW23B BARS (1/2 E.F.),
(36) #6 FW22B BARS (1/2 TOP & BOTTOM),
(36) #6 DOWELS (1/2 E.F.)
ELEVATION E-E
ELEVATION OF WINGWALL FILL FACE
DETAIL "C"
S1-S7_DE
NTS
01.22.2013
NOTE:
THIS DRAWING NOT TO SCALE. FOLLOW DIMENSIONS.
B
A
A
G
BENT 1
BENT 2
B
BENT 1 ELEVATIONS
LOCATION
ELEVATION
A
889.00
B
895.75
C
893.79
D
894.04
E
F
G
889.00
F
BENT 2 ELEVATIONS
B
F
E
LOCATION
ELEVATION
A
895.00
B
895.75
C
893.79
D
894.04
893.79
E
893.79
895.75
F
895.75
G
890.75
C
D
D
E
C
F
B
B
F
A
B
G
A
PLAN - END BENT AND WINGWALL ELEVATIONS
F
B
E
D
F
C
B
E
G
A
ELEVATION "A-A"
D
C
B
A
G
ELEVATION "B-B"
S8_DE
NTS
01.22.2013
NOTE:
THIS DRAWING NOT TO SCALE. FOLLOW DIMENSIONS.
25'-0"
DESIGN SPECIFICATIONS:
1.
AFTER BEAMS HAVE BEEN ERECTED, HOLES SHALL BE DRILLED INTO
SUBSTRUCTURE AND ANCHOR BOLTS PLACED. ANCHOR HOLES SHALL BE
FILLED WITH NON-SHRINK GROUT TO TOP OF BEAM AND ALLOWED TO
CURE MIN. 24 HOURS PRIOR TO GROUTING THE SHEAR KEYS. ANCHOR
BOLTS SHALL BE EQUIVALENT TO ASTM A 307.
THE CONTRACTOR SHALL FOLLOW THE SPECIFICATIONS AS STATED IN THE "MISSOURI STANDARD
SPECIFICATIONS FOR HIGHWAY CONSTRUCTION," 2011 AND CURRENT SUPPLEMENTAL
SPECIFICATIONS REVISIONS.
DESIGN LOADING:
HS20-44
SEISMIC PERFORMANCE CATEGORY 'A'
EARTH --- 120 PSF
EQUIVALENT FLUID PRESSURE --- 45 POUNDS/CU. FT.
35 POUND/SQUARE FOOT FUTURE WEAR SURFACE SUPERSTRUCTURE:
SIMPLY SUPPORTED NON-COMPOSITE FOR DEAD AND LIVE LOADS.
CONCRETE
REINFORCING STEEL STRUCTURAL
CARBON STEEL
6'-0"
TYP. SEE CROSS SECTION
SEE SHEET S6
f'c = 6,000 psi
fy = 60,000 psi
fy = 50,000 psi
6"
6"
6'-0"
6'-0"
6"
LONGITUDINAL KEYS SHALL BE GROUTED.
3.
THE 1" DIAMETER RODS IN THE TRANSVERSE TIE ASSEMBLY SHALL BE
TIGHTENED TO A SNUG FIT AND THE THREADS SET. POCKETS THAT
RECEIVE TRANSVERSE TIE BAR OUTSIDE SHALL BE FILLED WITH GROUT
AFTER TRANSVERSE TIE ASSEMBLY IS IN PLACE. SEE SHEET S6 FOR
DETAILS. TIE RODS SHALL BE ASTM A36.
4.
USE RECESSED LIFT ANCHORS ON EACH END. FOLLOW MANUFACTURER'S
RECOMMENDATIONS FOR INSTALLATION.
5.
ALL REBAR IN PRECAST DECK BEAMS SHALL BE EPOXY COATED.
6.
DO NOT LIFT BEAMS UNTIL CONCRETE STRENGTH IS EQUAL TO 3500 PSI.
7.
PROVIDE A TYNE FINISH ON TOP OF BEAMS WITH DEPTH OF TYNES 1/4".
8.
JOINT FILLER MUST BE IN PLACE PRIOR TO SETTING SLAB BEAMS.
9.
SLAB BEAMS MUST MEET A DEFLECTION CRITERIA OF L/800
10.
SUPPLIER NEEDS TO BE PRE APPROVED
11.
NOMINAL 1" JOINT AT CENTERLINE PIER SHALL BE FILLED WITH JOINT
FILLER. SEAL JOINT WITH SONOLISTIC NFI BY SONNEBORN SEALANT
SYSTEMS OR APPROVED EQUAL.
12.
SHOP DRAWINGS SHALL BE SUBMITTED FOR REVIEW AND APPROVAL.
6"
6'-0"
6"
6'-0"
6"
CENTERLINE ROADWAY
PROFILE GRADE LINE
SHEAR KEYS TYP.
SEE NOTE 2
SLOPE = 2%
2.
6'-0"
12'-6"
12'-6"
NOTES:
2002 A.A.S.H.T.O. STANDARD SPECIFICATIONS FOR
HIGHWAY BRIDGES, 17TH EDITION AND CURRENT
INTERIMS
6'-0"
SLOPE = 2%
1/4" JOINT-TYP.
(8) PRECAST CONCRETE DECK BEAMS @ 3'-1 1/4" + 1/4" JOINTS = 25'-0"
TYPICAL CROSS SECTION OF ROADWAY
(NEAR CL OF STRUCTURE)
8" CURB (TYP.)
TYPICAL SLAB CAMBER
CL BENT
SEE NOTE 1 (TYP.)
1"Ø X 36.5" H.A.S. THREADED
ROD (TYP.) WITH NUT AND
1/4" WASHER (2 EACH BEAM)
TRANSVERSE TIES
(SEE NOTE 3)
CL BRIDGE
SEE NOTE 2
(TYP.)
1'-0"
12'-6"
1'-0"
SEE NOTE 4 (TYP.)
SEE NOTE 4
(TYP.)
1'-0"
3"Ø OPEN HOLE TO BE
FILLED WITH APPROVED
NON-SHRINK GROUT AFTER
BOLT AND NUT HAVE BEEN
INSTALLED.
1 1/2"Ø OPEN HOLE TO BE
FILLED WITH HIGH STRENGTH
NON-SHRINK EPOXY GROUT.
(TYP). (2 EACH BEAM)
FIELD DRILL 1 1/8"Ø X 1'-3"
HOLE. PLACE THREADED
ROD WITH APPROVED
ADHESIVE (HILTI HIT RE-500
OR APPROVED EQUAL).
2"
SEE NOTE 1
(TYP.)
(8) DECK BEAMS
25'-0"
12'-6"
NOT TO SCALE
FILL AREA UNDER GIRDER
WITH JOINT FILLER (SEE
NOTE 8)
1/2" ELASTOMERIC
BEARING PAD
SECTION AT ABUTMENTS
(ALONG CL BEAMS)
4'-0"
12"
12"
22'-6"
22'-6"
45'-0"
SLAB BEAM LAYOUT PLAN
S9-S11_DE
NTS
01.22.2013
NOTE:
THIS DRAWING NOT TO SCALE. FOLLOW DIMENSIONS.
NOTE:
1. USE DAYTON/RICHMOND D-4 HEX COUPLING NUT FOR CONNECTING 1"Ø THREADED RODS. ALTERNATE APPROVED TRANSVERSE TIE RODS OF
INCREASED SEGMENTAL LENGTH ARE ACCEPTABLE, INCLUDING 1 CONTINUOUS TIE ROD THROUGH ALL DECK BEAMS.
8 3/8"
1'-0"
PLAN OF STIRRUP SPACING DETAIL
CL BEAM
3"
9 SPACES @ 6" CTS.
(8) TRADITIONAL STIRRUPS
5 SPACES @ 9" CTS.
(2) DOUBLE STIRRUPS
9" (6) DOUBLE STIRRUPS 1'-0"
1'-0"
12 SPACES @ 12" CTS.
(1) TRADITIONAL STIRRUPS
(12) DOUBLE STIRRUPS
B
A
B
A
12 SPACES @ 12" CTS.
(1) TRADITIONAL STIRRUPS
(12) DOUBLE STIRRUPS
6"
5 SPACES @ 9" CTS.
1'-0" (6) DOUBLE STIRRUPS
9 SPACES @ 6" CTS.
(8) TRADITIONAL STIRRUPS
(2)
DOUBLE STIRRUPS
9"
4'-0"
TYPICAL END BENT
TYPICAL END BENT
45'-0"
ELEVATION OF STIRRUP SPACING DETAIL
4"ROUND x1/2" PL
WASHER FOR 10° SKEW
SEE NOTE 1
CL SPAN
WASHERS ON 0° SKEW
OUTSIDE BEAM
1/4"
4 1/2"
1/2"
11 1/2"
NUT FOR 1"
DIA. ROD
3"
TRANSVERSE TIE
ASSEMBLY SHALL BE
GALVANIZED PER ASTM123
3" DIA. OPENING
1" DIA. RODS (THREAD EACH
END 4") SEE NOTE 3
SECTION ALONG TRANSVERSE TIE ASSEMBLY
SEE NOTE 3
PARTIAL PLAN
TRANSVERSE TIE ASSEMBLY
('D'=0°)
S9-S11_DE
NTS
01.22.2013
NOTE:
THIS DRAWING NOT TO SCALE. FOLLOW DIMENSIONS.
5"
1"
REFER TO INTERIOR BEAM
SECTION FOR LONGITUDINAL
BAR SIZE AND SPACING
2'-10 1/4"
(OUTSIDE BAR DIMENSION)
#4
BARS
8"
8"
#4
BARS
REFER TO INTERIOR BEAM
SECTION FOR LONGITUDINAL
BAR SIZE AND SPACING
#4 BAR @ 9"
SEE CURB
BAR DETAIL
#4 BAR @ 9"
SEE CURB
BAR DETAIL
2"
1'-6" MIN.
23"
#4 STIRRUPS (SEE
BEAM LAYOUT FOR
SPACING)
1'-6" MIN.
23"
1"
3/4" RADIUS
TYP.
12"
3"
3"
SEE "SINGLE LEG OF
DOUBLE STIRRUP"
STIRRUP DETAIL
11"
SEE "TRADITIONAL"
STIRRUP DETAIL
2"
1'-6 1/2"
(OUTSIDE BAR DIMENSION)
5"
3/4" RADIUS
TYP.
3"
3"
3/4" CHAMFER
TYP.
3'-1 1/4"
TYPICAL CROSS SECTION B-B
(EXTERIOR BEAM)
NOT TO SCALE
(EXTERIOR BEAM)
NOT TO SCALE
2 1/2"
2 1/2"
3"
3'-1 1/4"
TYPICAL CROSS SECTION A-A
1/2"
3 5/8"
2 1/2"
(6) #5 BARS (AS SHOWN)
1'-6 1/2"
3/4" CHAMFER
TYP.
2 1/2"
(6) #5 BARS (AS SHOWN)
7 7/8"
CL ANCHOR HOLES
EACH END
7 7/8"
1'-8 5/8"
4 1/2"
4"
1"
1 1/2"
2 5/8"
2"
(8) #8 BARS EA. SPACED
AS SHOWN (TOP & BOT) (SIM.)
2"
3"
3"
1'-0"
1 1/2"
1"
SEE "SINGLE LEG OF
DOUBLE STIRRUP"
STIRRUP DETAIL
SEE "TRADITIONAL"
STIRRUP DETAIL
1 1/2"
1"
23"
3/4"
3"
1 1/2"
1"
1 1/2"
1"
3/4" CHAMFER
TYP.
9 5/8"
(SINGLE LEG OF DOUBLE STIRRUP)
#4 STIRRUPS (SEE BEAM
LAYOUT FOR SPACING)
3/4"
23"
3"
3"
4 1/2"
3"
4"
3"
1/2"
3/4" CHAMFER
TYP.
1"
2 5/8"
(8) #8 BARS EA. SPACED
AS SHOWN (TOP & BOT) (SIM.)
2"
2"
3"
1'-6"
3'-1 1/4"
3'-1 1/4"
TYPICAL
CROSS SECTION A-A
Interior Beam
(INTERIOR BEAM)
NOT TO SCALE
TYPICAL CROSS SECTION B-B
(INTERIOR BEAM)
NOT TO SCALE
S9-S11_DE
NTS
01.22.2013
NOTE:
THIS DRAWING NOT TO SCALE. FOLLOW DIMENSIONS.
S12-S13_DE
NTS
01.22.2013
SHAPE 15
C
C
SHAPE 24
1
H
SHAPE 32
#2 GAGE (CORRUGATED
PREFERRED) (SMOOTH
ACCEPTABLE)
#4 GAGE 2"-5" HEIGHT
#2 GAGE OVER 5"-9"
#0 GAGE OVER 9" HEIGHT
K
H
C
D
D
CONTINUOUS HIGH CHAIR - (CHC)
SHAPE 33
SHAPE 26
EPOXY OR PLASTIC
D
(IN.)
#3
#4
#5
#6
1 1/2"
2"
2 1/2"
4 1/2"
4"
4 1/2"
6"
8"
4"
4 1/2"
5 1/2"
7"
2 1/2"
3"
3 3/4"
4 1/2"
NOTE:
UNLESS OTHERWISE NOTED DIAMETER "D" IS THE SAME
FOR ALL BENDS AND HOOKS ON A BAR.
D
*
1
SYMMETICAL
ABOUT CL
BALL FOOT
#5 GA
ELEVATION
SECTION
HOOK
A OR G
d
J
90°
H
180°
D
ALL REINFORCING IN END BENTS INCLUDED WITH SUPERSTRUCTURE
QUANTITIES.
BENDING DIAGRAMS
NOTES:
ALL STANDARD HOOKS AND BENDS OTHER THAN 180 DEG TO BE BENT WITH
SAME PROCEDURE AS FOR 90 DEG. STD. HOOKS
HOOKS AND BENDS SHALL BE IN ACCORDANCE WITH THE PROCEDURES AS
SHOWN ON THIS SHEET
E - EPOXY COATED REINFORCEMENT
S - STIRRUP
X - BAR IS INCLUDED IN SUBSTRUCTURE QUANTITIES
V - BAR DIMENSIONS VARY IN EQUAL INCREMENTS BETWEEN DIMENSIONS
ØD
90°
SIZE OF 180° HOOKS GRADE 40 KSI
D = 6d FOR #3 THRU #8
D = 8d FOR #9, #10 AND #11
D = 10d FOR #14 AND #18
135°
SLAB BOLSTER - (SB)
D
(IN.)
#3
#4
#5
#6
#7
#8
#9
#10
2 1/4"
3"
3 1/4"
4 1/2"
5 1/4"
6"
9 1/2"
10 1/4"
*
BAR SUPPORTS
FOR CONCRETE
REINFORCEMENT
SIZE OF 90° HOOKS ALL
GRADES AND 180° HOOKS
GRADE 60 KSI
END HOOK DIMENSIONS
BAR
SIZE
BALL
FOOT
SECTION
DETAILING
DIMENSION
ØD
4d OR 2 1/2" MIN
d
KNUCKLED FOOT
*COATED WHEN USED TO SUPPORT COATED REINFORCEMENT.
d
HOOK
A OR G
CL BEAM
DETAILING
DIMENSION
GRADES 40-50-60 KSI
90° HOOKS
135° HOOKS
HOOK
HOOK
APPROX.
A OR G
A OR G
H
Ø
DETAILING
DIMENSION
D
BAR
SIZE
ØD
A OR G
d
6d OR 2 1/2" MIN
Ø
END HOOK DIMENSIONS
DETAILING
DIMENSION
CL BEAM
5"
#4 GAGE
CORRUGATED
GENERAL NOTES:
ALL GAGES GIVEN ARE AMERICAN STEEL AND WIRE GAGES. ALL STEEL TO BE AMERICAN.
ALL CONTACT POINTS TO BE SECURELY WELDED. USE A BALL OR KNUCKLED FOOT ON ALL BAR SUPPORTS
BEARING ON FORMS. WHERE BAR SUPPORTS ARE USED ON EARTH OR AGGREGATE SUBGRADES
SUITABLE PLATES OR CONTINUOUS BARS SHALL BE PROVIDED TO PREVENT DISPLACEMENT OF THE
SUPPORT FOOT.
ALL DIMENSIONS TO REINFORCING STEEL ARE TO C/L BAR EXCEPT WHERE CLEAR DISTANCE FROM FACE
OF CONCRETE IS INDICATED.
HEIGHT OF BAR SUPPORTS TO BE THAT REQUIRED TO SUPPORT BARS IN EXACT POSITIONS SHOWN ON
PLANS.
WHEN BARS OF DIFFERENT SIZES ARE USED IN THE SAME MEMBERS, THE SELECTION OF BAR SUPPORTS
SHALL BE BASED ON THE LARGER SIZE.
SUPPORTS FOR UPPER LAYERS NEED NOT BE DIRECTLY OVER THE SUPPORTS BELOW. PORTIONS TO BE
BENDING DIAGRAM
6d FOR #3 THRU #5 12d
FOR #6 OR 2 1/2" MIN
1°
PART SECTION G-G
SLABS ON PRECAST PRESTRESSED PANELS
15°
KNUCKLED
FOOT
ELEVATION
D
CLEAR DISTANCE AS SPECIFIED ON PLANS
MAX SPACING POSSIBLE. SUPPORTS FOR UPPER LAYERS
NEED NOT BE DIRECTLY OVER THE SUPPORTS BELOW.
2"*
SHAPE 31
TOP OF PRECAST
PRESTRESSED
PANELS
PART SECTION F-F
1 1/4"
C
2
1/8" MIN
3/8" MAX
45°
H
D
D
C
1
PREFERRED LEG
CONFIGURATION-LEG
WITHOUT BEND
ACCEPTABLE
8 1/4" (MAX)
2"*
F
CL GIRDER
PART CROSS SECTION
K
B
E
B K
D
D
B
H
B
C
1"±
SHAPE 29
H
B
F
C
SHAPE 25
K F
SHAPE 30
SHAPE 23
VERTICAL
LEG
C
K
E
B
H
E
H
B
K
C
K
D
PRECAST PRESTRESSED PANELS
12d
H B
D
E
B
D
D
E
K
B
SHAPE 22
SHAPE 21
F
C
B
C
B K
C
SHAPE 28
A
G
TOP OF
SLAB
G
F
5"±
H
C
SHAPE 27
H
B
D
SHAPE 19
1Ð TURNS
E
B
H
A
C
C
SPOTWELD
#2 BARS
H B
K D
SHAPE 12 SHAPE 13
K
H
H
SHAPE 20
C
(SB)
(SB)
A OR G
SHAPE 14
SHAPE 16
E
TOP OF
SLAB
(CHC)
"
/32
D
SHAPE 18
D
K
G
(SB)
R5
K
C
C
SHAPE 11
G
B
3" PITCH
A
D
SHAPE 10
SHAPE 9
B
E
B
C
B B
D
C
SHAPE 8
VERTICAL
LEG
G
E
12" (SB) 2'-0"
(MAX) MAX SPA.
/4"
R3
C
E
C
B
SHAPE 7
E
D
SHAPE 6
SHAPE 17
B
B
H
K
K F
A
D
C
B
C
H
B
D
B
LA A
P
2
(CHC)
B
K
B
E
B
K
H
C
3" CLR
F
180° HOOKS
ALL GRADES
A OR G
J
5"
3"
6"
4"
7"
5"
8"
6"
10"
7"
11"
8"
15"
11 1/4"
17"
12 3/4"
90° HOOKS
ALL GRADES
A OR G
6"
8"
10"
12"
14"
16"
19"
22"
SHOWN ON THIS LINE AND THE FOLLOWING LINE
NO. EA. NUMBER OF BARS OF EACH LENGTH
NOMINAL LENGTHS ARE BASED ON OUT TO OUT DIMENSIONS SHOWN IN BENDING
DIAGRAMS AND ARE LISTED FOR FABRICATORS USE (NEAREST INCH ACTUAL LENGTHS
ARE MEASURED ALONG CENTERLINE BAR TO THE NEAREST INCH
PAYWEIGHTS ARE BASED ON ACTUAL LENGTHS.
S12-S13_DE
NTS
01.22.2013
NOTE:
THIS DRAWING NOT TO SCALE. FOLLOW DIMENSIONS.
PUBLIC NOTICE
Permit No. NWK-2014-1161
Issue Date: January 14, 2015
Expiration Date: February 13, 2015
US Army Corps
of Engineers
Kansas City District
30-Day Notice
______________________________________________________________________________
APPLICANT/IN-LIEU FEE SPONSOR: Missouri Conservation Heritage Foundation
P.O. Box 366
Jefferson City, Missouri 65102-0366
PROJECT LOCATION (As shown in the referenced mitigation plan): The proposed
mitigation plan No. SSTF1004-Dallas County is located along Hays Road at an existing
crossing in Greasy Creek in the northeast ¼ of Section 6, Township 33 north, Range 19 west,
Dallas County, Missouri. The project is within the Ozark/Osage Ecological Drainage Unit
(EDU) [USGS QUAD Charity -- Latitude: 37.612448 -- Longitude: -93.067558].
AUTHORITY: Section 404 of the Clean Water Act (33 USC 1344).
ACTIVITY (As described in the referenced mitigation plan): The Missouri Conservation
Heritage Foundation (Sponsor) proposes under its Stream Stewardship Trust Fund (SSTF)
In-Lieu Fee (ILF) Instrument to establish mitigation plan No. SSTF1004-Dallas County entitled
the Hayes Road Low Water Crossing Replacement Project. A draft copy of the mitigation plan
has initially been reviewed by the Interagency Review Team (IRT) which is composed of
representatives from the U.S. Environmental Protection Agency, the U.S. Fish and Wildlife
Service, the Missouri Department of Natural Resources, and the Missouri Department of
Conservation.
The mitigation plan consists of initiating construction work on Hays Road in Dallas County to
remove a low water crossing in Greasy Creek and replace it with a clear-span bridge. The
existing crossing is a vented ford with three concrete box culverts. The crossing blocks passage
of aquatic organisms during low flows because the culverts slabs are perched above the
streambed. During moderate to high flows the crossing creates currents with high velocity that
damage downstream banks. The existing crossing will be demolished and hauled from the site.
Once removed a new low water bridge (clear-span design) will be constructed on the same
footprint as the existing crossing. The mitigation plan with design drawings is posted at:
http://www.nwk.usace.army.mil/Media/PublicNotices.aspx. This crossing is one of five
crossings that were previously identified as fish passage barriers in the Niangua River watershed.
Replacement of the crossing will increase fish passage, improve stream sediment transport, and
increase stream stability within this reach. In addition, the new crossing will be used as a
demonstration project for the Dallas County Road Department. The Sponsor proposes to enter
into a 30-year term cooperative agreement with the county to provide standard maintenance for
the project. This proposed agreement would not alleviate the Sponsor from their responsibility
for the long term protection and management of this SSTF-funded project as described in their
ILF instrument. The project is partially funded by Dallas County, the U.S. Fish & Wildlife
Service, and the Missouri Department of Conservation.
If approved by the Corps, in consultation with the IRT, the project will have a total potential of
11,500 mitigation credits minus a partial reduction of credits that would be generated from use of
federal funds for the project as required by the 2008 Mitigation Rule.
APPLICANT'S STATEMENT OF AVOIDANCE, MINIMIZATION, AND
COMPENSATORY MITIGATION FOR UNAVOIDABLE IMPACTS TO AQUATIC
RESOURCES: The project is proposed under the Sponsor's ILF instrument as compensatory
mitigation for stream impacts authorized by Department of the Army permits. The Sponsor has
avoided and minimized impacts to waters of the U.S. to the maximum extent practicable through
project design.
ADDITIONAL INFORMATION: Additional information about this application may be
obtained by contacting Mr. James A. Ptacek, U.S. Army Corps of Engineers, Missouri State
Regulatory Office, 221 Bolivar Street, Suite 103, Jefferson City, Missouri 65101, telephone
No. 816-389-3834, or email to james.a.ptacek@usace.army.mil. All comments to this public
notice should be directed to the above address.
CULTURAL RESOURCES: Kansas City District will comply with the National Historic
Preservation Act of 1966 and 36 CFR 800. We have checked the National Register of Historic
Places and the Federal Register and no property listed in the Register or proposed for listing is
located in the permit area. This is the extent of our knowledge about historic properties in the
permit area at this time. However, we will evaluate input by the State Historic Preservation
Officer, Tribal Historic Preservation Officers (or Tribe designated representative) and the public
in response to this public notice, and we may conduct or require a reconnaissance survey of the
permit area to check for unknown historic properties, if warranted.
ENDANGERED SPECIES: Greasy Creek is a major western tributary to the Niangua River. It
contains 12.9 miles within the known range of the federally threatened Niangua Darter,
Etheostoma nianguae. The U.S. Fish and Wildlife Service will serve as the lead federal agency
responsible for Endangered Species Act compliance via Section 7 consultation by developing an
effects determination as result of the proposed project toward the species and/or any critical
habitat. Once the determination is made, it will become part of the decision document. The
USACE is also requesting any comments from other interested agencies and individuals.
FLOODPLAINS: This activity is being reviewed in accordance with Executive Order 11988,
Floodplain Management, which discourages direct or indirect support of floodplain development
whenever there is a practicable alternative. By this public notice, comments are requested from
individuals and agencies that believe the described work will adversely impact the floodplain.
WATER QUALITY CERTIFICATION: If authorized, this project will meet the conditions of
a nationwide permit, which presently has certification under Section 401 of the Clean Water Act
(33 USC 1341) in compliance with applicable effluent limitations and water quality standards.
Certification expresses the state's opinion that the discharge will not violate applicable water
quality standards.
PUBLIC INTEREST REVIEW: The decision to approve the mitigation plan and verify
compliance with a nationwide permit will be based on an evaluation of the probable impact
including the cumulative impacts of the proposed activity on the public interest. That decision
will reflect the national concern for both protection and utilization of important resources. The
benefits which reasonably may be expected to accrue from the proposal must be balanced against
its reasonably foreseeable detriments. All factors which may be relevant to the proposal will be
considered including the cumulative effects thereof; among those are conservation, economics,
esthetics, general environmental concerns, wetlands, cultural values, fish and wildlife values,
flood hazards, floodplain values, land use, navigation, shoreline erosion and accretion,
recreation, water supply and conservation, water quality, energy needs, safety, food and fiber
production, mineral needs and, in general, the needs and welfare of the people. The evaluation
of the impact of the activity on the public interest will include application of the guidelines
promulgated by the Administrator, Environmental Protection Agency under authority of Section
404(b) of the Clean Water Act (33 USC 1344). The Corps of Engineers is soliciting comments
from the public; Federal, state, and local agencies and officials; Indian Tribes; and other
interested parties in order to consider and evaluate the impacts of this proposed activity. Any
comments received will be considered by the Corps of Engineers to determine whether to issue,
modify, condition or deny a permit for this mitigation plan. To make this decision, comments
are used to assess impacts on endangered species, historic properties, water quality, general
environmental effects, and the other public interest factors listed above. Comments are used in
preparation of an Environmental Assessment and/or an Environmental Impact Statement
pursuant to the National Environmental Policy Act. Comments are also used to determine the
need for a public hearing and to determine the overall public interest of the proposed activity.
COMMENTS: This notice is provided to outline details of the above described activity so this
District may consider all pertinent comments prior to determining if issuance of a permit would
be in the public interest. Any interested party is invited to submit to this office written facts or
objections relative to the activity on or before the public notice expiration date. Comments both
favorable and unfavorable will be accepted and made a part of the record and will receive full
consideration in determining whether it would be in the public interest to issue the Department of
the Army permit. Copies of all comments, including names and addresses of commenters, may
be provided to the applicant. Comments should be mailed to the address shown on page 2 of this
public notice.
PUBLIC HEARING: Any person may request, in writing, prior to the expiration date of this
public notice, that a public hearing be held to consider this application. Such requests shall state,
with particularity, the reasons for holding a public hearing.
Section 6, Township 33 north, Range 19 west
APPLICATION NO. NWK-2014-1161
MISSOURI CONSERVATION HERITAGE FOUNDATION
LOW WATER CROSSING REMOVAL/BRIDGE REPLACEMENT
GREASY CREEK
DALLAS COUNTY, MISSOURI
SHEET 1 OF 1
DATED 14 JANUARY 2015